Pure IP-PBX Getting Started for Physical Cards Model No. KX-TDE100 KX-TDE200 Thank you for purchasing a Panasonic Pure IP-PBX. Please read this manual carefully before using this product and save this manual for future use. KX-TDE100/KX-TDE200: PMMPR Software File Version 7.0000 or later

Getting Started for Physical Cards · 2016. 5. 24. · Example: KX-TDE200 IPCMPR Card SD CARD 2 4 5 SD CARD SD Memory Card 3 1 CAUTION Do not remove the SD Memory Card while power

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • Pure IP-PBX

    Getting Started

    for Physical Cards

    Model No. KX-TDE100KX-TDE200

    Thank you for purchasing a Panasonic Pure IP-PBX.

    Please read this manual carefully before using this product and save this manual for future use.

    KX-TDE100/KX-TDE200: PMMPR Software File Version 7.0000 or later

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • Table of Contents1 Before Installation ....................................................................................31.1 Safety Notices ...................................................................................................................41.2 System Connection Diagram ...........................................................................................51.3 Unpacking ..........................................................................................................................6

    2 Installation ................................................................................................92.1 Opening/Closing the Front Cover ..................................................................................102.2 Inserting the SD Memory Card to the IPCMPR Card ....................................................112.3 Installing the Option Units .............................................................................................122.4 Installing the Trunk Cards ..............................................................................................142.5 Installing the Extension Cards (DLC8/DLC16/DHLC8/MSLC16/SLC8/SLC16/

    CSLC16) ...........................................................................................................................172.6 Connecting Extensions ..................................................................................................172.7 Frame Earth Connection ................................................................................................18

    3 Before Programming .............................................................................193.1 Starting the PBX ..............................................................................................................203.2 Connecting the PC ..........................................................................................................213.3 Installing the Maintenance Console ..............................................................................22

    4 Programming ..........................................................................................234.1 Programming the PBX ....................................................................................................24

    5 Confirming the Connection ...................................................................295.1 Making and Receiving Calls ...........................................................................................30

    2 Getting Started for Physical Cards

    Table of Contents

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • Section 1

    Before Installation

    Getting Started for Physical Cards 3

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 1.1 Safety NoticesPlease observe the safety notices in this manual in order to avoid danger to users or other people, and preventdamage to property.The notices are classified as follows, according to the severity of injury or damage:

    WARNING

    This notice means that misuse could result in death or serious injury.

    CAUTION

    This notice means that misuse could result in injury or damage toproperty.

    4 Getting Started for Physical Cards

    1.1 Safety Notices

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 1.2 System Connection Diagram

    MSLC16(KX-TDA0175)

    SLC8(KX-TDA0173)

    EXT-CID(KX-TDA0168)

    SLC16(KX-TDA0174)

    E1(KX-TDA0188)

    IP-GW4E(KX-TDA0484)

    IP-GW16(KX-TDA0490)

    PRI30(KX-TDA0290CE/KX-TDA0290CJ)

    PRI23(KX-TDA0290)

    BRI4(KX-TDA0284)

    BRI8(KX-TDA0288)

    T1(KX-TDA0187)

    E&M8(KX-TDA0184)

    DID8(KX-TDA0182)

    PSU-S/PSU-M/PSU-L

    (KX-TDA0108/KX-TDA0104/KX-TDA0103)

    DLC16(KX-TDA0172)

    DLC8(KX-TDA0171)

    DHLC8(KX-TDA0170)

    LCOT4(KX-TDA0183)

    LCOT16(KX-TDA0181)

    LCOT8(KX-TDA0180)

    CID/PAY8(KX-TDA0189)

    CID8(KX-TDA0193)

    CSLC16(KX-TDA0177)

    SLTFaxMachine

    SLT(DHLC only)

    Wireless Phone(DHLC only)

    APT(DHLC only)

    DPT

    Voice Processing System

    DSSConsole

    PT-interface CS PS

    Radio

    Amplifier Pager/Speaker

    CSIF4(KX-TDA0143)

    CSIF8(KX-TDA0144)

    CS PS

    Private IP Network

    Station Message DetailRecording (SMDR)

    Router

    Batteries

    IP-EXT16(KX-TDA0470)

    OPB3(KX-TDA0190)

    DPH4(KX-TDA0161)

    DPH2(KX-TDA0162)

    ECHO16(KX-TDA0166)

    EIO4(KX-TDA0164)

    MSG4(KX-TDA0191)

    Doorphone & Door Opener

    IP-PT

    LAN

    External Sensor/External Relay Device

    IP Softphone

    ISDN BRI LineISDN BRI Line(Digital Trunk)(Digital Trunk)ISDN BRI Line(Digital Trunk)

    ISDN PRI LineISDN PRI Line(Digital Trunk)(Digital Trunk)ISDN PRI Line(Digital Trunk)

    T1 LineT1 Line(Digital Trunk)(Digital Trunk)

    T1 Line(Digital Trunk)

    AnalogueAnalogueTrunkTrunk

    AnalogueTrunk

    E & M LineE & M LineE & M Line

    E1 LineE1 Line(Digital Trunk)(Digital Trunk)

    E1 Line(Digital Trunk)

    TelephoneCompany

    Router

    PCIP Softphone,

    CA*3 Client PC

    LAN

    CTI Server

    IPCMPR

    (Installed by default)

    IP-PT SIP Extension

    V-SIPGW16

    V-IPGW16

    Virtual Trunk SlotPrivate IP

    Network

    Mountable Equipment

    PC

    ITSP*1 Network

    DCE*2(e.g., ADSL

    Modem)

    Router

    WAN

    DSP16(KX-TDE0110)

    DSP64(KX-TDE0111)

    RMT(KX-TDA0196)

    ESVM2(KX-TDA0192)

    ESVM4(KX-TDA0194)

    KX-DT300/KX-T7600 DPT

    KX-DT300/KX-T7600DPT

    PCKX-DT346/KX-DT343/KX-T7636/KX-T7633 DPT

    IP-CS PS

    V-SIPEXT32

    V-IPEXT32

    Virtual Extension Slot

    V-IPCS4

    IPCMEC(KX-TDE0105)

    *1 ITSP: Internet Telephony Service Provider*2 DCE: Data Circuit Terminating Equipment*3 CA: Communication Assistant

    Getting Started for Physical Cards 5

    1.2 System Connection Diagram

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 1.3 UnpackingCheck the package contents.Main Unit ´ 1CD-ROM (including manuals, etc.) ´ 1

    AC Cord*1 ´ 1 Screw A´ 3 (KX-TDE100)´ 4 (KX-TDE200)

    Screw B (Black)´ 2 (KX-TDE100)´ 6 (KX-TDE200)

    Anchor Plug´ 3 (KX-TDE100)´ 4 (KX-TDE200)

    SD Memory Card ´ 1 Ferrite Core (for the IPCMPRcard) ´ 2

    for KX-TDE100 for KX-TDE200

    Metal Bracket ´ 1

    *1 The type of the AC cord may vary depending on the country/area of use.The KX-TDE100BX/KX-TDE200BX is supplied with 2 types of AC cord. Please use whichever is appropriate for the country/area.In Canada, there is no ferrite core attached to the AC cord.

    NoteIn this manual, the suffix of each model number (e.g., KX-TDE100NE) is omitted unless necessary.

    6 Getting Started for Physical Cards

    1.3 Unpacking

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • Necessary items (not supplied):ü Telephone cable for extension connection:

    Diameter of cable(ø 0.4 mm to ø 0.6 mm) Maximum length of cable

    ø 0.5 mm 1128 m for SLT

    ø 0.5 mm 720 m for KX-DT300/KX-T7600 series

    ø 0.5 mm 229 m for other DPT, APT and DSS Console

    The maximum length of the cable may vary depending on the type of cable and installation conditions.ü An RS-232C cross cable or Ethernet straight cable for PC connectionü Connectors (Amphenol/RJ45/BNC) for trunk and extension connections

    Note• The Ethernet straight cable should be a 10BASE-T/100BASE-TX CAT 5 (Category 5) or higher cable.• Use a shielded twisted pair cable for the Amphenol connector.• Use a twisted pair cable for the RJ45 connector.

    Getting Started for Physical Cards 7

    1.3 Unpacking

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 8 Getting Started for Physical Cards

    1.3 Unpacking

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • Section 2

    Installation

    Getting Started for Physical Cards 9

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 2.1 Opening/Closing the Front CoverOpening the Front Cover

    1. Insert a flathead screwdriver into the opening (on the left of the screw cover) and unlatch the screw cover.Turn the screw anticlockwise to loosen.

    2. Slide the front cover to the right until it stops, then lift the front cover.

    Closing the Front Cover1. Hook the front cover onto the shelf (line up the protrusions on the cover with the receptacles on the shelf),

    then slide the front cover to the left until it locks.

    2. Turn the screw clockwise to tighten, then secure the screw cover.

    2

    1

    10 Getting Started for Physical Cards

    2.1 Opening/Closing the Front Cover

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 2.2 Inserting the SD Memory Card to the IPCMPRCard

    The SD Memory Card contains software for all the processes of the PBX and all the customer data.The SD Memory Card must be inserted before startup.

    Example: KX-TDE200

    IPCMPR Card

    SDCARD

    2SD

    CARD

    4 5

    SDCARD

    SDMemoryCard

    3

    1

    CAUTIONDo not remove the SD Memory Card while power is supplied to the PBX. Doing so may cause the PBX tofail to start when you try to restart the system.

    Getting Started for Physical Cards 11

    2.2 Inserting the SD Memory Card to the IPCMPR Card

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 2.3 Installing the Option UnitsSlot Position

    Install the power supply unit (PSU) into the PSU slot, and optional service cards into free slots.

    KX-TDE100 KX-TDE200

    PSU SlotNull Slot*1Free SlotsIPCMPR Card

    *1 Null slot is not available for any optional service card.

    CAUTIONTo protect the back board from static electricity, do not touch parts on the back board in the main unit,PSU, and on the optional service cards. To discharge static electricity, touch ground or wear an earthingstrap. Make sure the screws are tightened to earth the card securely.

    Installing the Power Supply Unit1. Insert the PSU along the guide rails.2. Push the release lever in the direction of the arrow, so that the PSU engages securely with the connector

    on the back board.

    12 Getting Started for Physical Cards

    2.3 Installing the Option Units

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 3. Turn the 4 screws clockwise, in the order indicated by the numbers 1 to 4, to fix the PSU.

    Guide Rail

    Back Board

    Release Lever

    Screws

    1

    3 2

    4

    Installing the Trunk/Extension Cards1. Insert the card along the guide rails.2. Holding the card as shown below, push the release lever in the direction of the arrow so that the card

    engages securely with the connector on the back board.3. Turn the 2 screws clockwise to fix the card in place.

    Guide Rail

    ReleaseLever

    Back Board

    Screws

    Be sure to cover each slot in which no optional service card is installed by using a Blank Slot Cover. For details,refer to "Covering the Blank Slots" in "3.2.7 Installing/Removing the Optional Service Cards" of the InstallationManual.

    Getting Started for Physical Cards 13

    2.3 Installing the Option Units

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 2.4 Installing the Trunk CardsLCOT4/LCOT8/LCOT16 Card

    Example: LCOT 16 Card

    Amphenol

    To trunk

    Accessories (included): Screws ´ 2User-supplied (not included): Amphenol connector

    14 Getting Started for Physical Cards

    2.4 Installing the Trunk Cards

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • BRI4/BRI8 CardExample: BRI8 Card To attach the ferrite core

    To NT1

    LINE 1 to

    LINE 8

    RJ45

    TX2(-)RX1(-)RX2(+)TX1(+)

    When using 1 or 2 cables:

    When using 3 or 4 cables:

    • For every 4 cables, use 1 ferrite core; aferrite core holds a maximum of 4 cables.

    • Attach the ferrite core as close to thecard’s connector as possible.

    Accessories (included): Ferrite core(s) ´ 1 (BRI4 card) or 2 (BRI8 card)User-supplied (not included): RJ45 connector

    CAUTIONConnect these optional service cards to the trunk through an NT1; do not connect to the U interface of thetrunk directly.

    NoticeWhen connecting the RJ45 connector, attach the included ferrite core.

    Note• LINE 5 to LINE 8 are for BRI8 card only.• These optional service cards have 100 W of terminal resistance. For use in point to multi-point

    connection, the cards must be placed at the end of the bus.

    Getting Started for Physical Cards 15

    2.4 Installing the Trunk Cards

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • PRI30/PRI23 CardExample: PRI30 Card To attach the ferrite core

    To NT1

    To NT1

    TX-

    RX-RX+

    RJ45

    TX+

    TX+

    TX-

    BNC (TX)

    RX-

    RX+

    BNC (RX)

    For RJ45

    120Ω

    75Ω

    120Ω

    75ΩOR

    For BNC

    5 cm

    Accessories (included): Ferrite core ´ 1User-supplied (not included): RJ45 or BNC connectors

    CAUTIONConnect these optional service cards to the trunk through an NT1; do not connect to the U interface of thetrunk directly.

    NoticeWhen connecting the RJ45 connector, attach the included ferrite core (except in Canada, where the ferritecore is not necessarily required).

    Note• In some countries/areas, the PRI30 card must not be connected to the Public Switched Telephone

    Network.• Use only 1 type of connector (RJ45 or BNC) for connection of PRI30 card; RJ45 and BNC cannot be

    used simultaneously. Set the termination switch to 120 W (default) or 75 W for connector type to beused.

    16 Getting Started for Physical Cards

    2.4 Installing the Trunk Cards

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 2.5 Installing the Extension Cards (DLC8/DLC16/DHLC8/MSLC16/SLC8/SLC16/CSLC16)

    Example: DHLC8 Card To attach the ferrite core

    Amphenol

    To extensions

    3 cm

    Accessories (included): Screws ´ 2, Ferrite core ´ 1User-supplied (not included): Amphenol connector

    NoteAttach the included ferrite core to the cable.

    2.6 Connecting ExtensionsExample: KX-T7600 Series DPT Pin Assignments

    To extension card

    RJ11

    TO MAIN UNIT

    / PABXDPT and DSS Console

    KX-T7000 Series SLT

    H L

    T R

    APT

    HTRL

    H L

    Getting Started for Physical Cards 17

    2.6 Connecting Extensions

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 2.7 Frame Earth Connection1. Loosen the screw.2. Insert an earthing wire (user-supplied).3. Tighten the screw.4. Connect the earthing wire to earth.

    To earth

    Earthing wire

    Screw

    WARNING• Proper earthing (connection to earth) is very important to reduce the risk to the user of

    electrocution or to protect the PBX from the bad effects of external noise in the case of alightning strike.

    • The earthing wire of the AC cable has an effect against external noise and lightning strikes, butit may not be enough to protect the PBX. A permanent connection between earth and the earthterminal of the PBX must be made.

    CAUTIONFor earthing wire, green-and-yellow insulation is required, and the cross-sectional area of the conductormust be more than 0.75 mm2 or 18 AWG.

    18 Getting Started for Physical Cards

    2.7 Frame Earth Connection

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • Section 3

    Before Programming

    Getting Started for Physical Cards 19

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 3.1 Starting the PBXCAUTION

    • Use only the AC power cord included with the PBX for the PSU.• Before touching the System Initialise Switch, discharge static electricity by touching ground or wearing

    an earthing strap.• Once you have started the PBX and if you unplug the PBX, do not perform the following procedures

    to start the PBX again. Otherwise, your programmed data will be cleared.• The power supply cord is used as the main disconnect device. Ensure that the AC outlet is located

    near the equipment and is easily accessible.

    NoticeThe SD Memory Card must be inserted in the SD Memory Card slot of the IPCMPR card before startup.

    NoteThe PBX will continue to be powered even if the power switch is turned "OFF".

    1. Slide the System Initialise Switch to the "SYSTEM INITIALIZE" position.

    System Initialise Switch

    SYSTEMINITIALIZE

    NORMAL

    Power

    Supply Unit

    RUN Indicator

    To AC Outlet

    2. Plug the AC power cord into the PBX and an AC outlet, and turn on the PBX. The RUN indicator will flash.3. While the RUN indicator is flashing, slide the System Initialise Switch back to the "NORMAL" position.

    Depending on the configuration, initialisation takes about 1 min to 3 min. If successfully executed, theRUN indicator will stop flashing and stay lit.

    All data will be cleared and the PBX will be initialised to the default values. The DPTs should show the timeas 01:00.

    20 Getting Started for Physical Cards

    3.1 Starting the PBX

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 3.2 Connecting the PCThe Maintenance Console serves as an overall system programming tool for the PBX. The MaintenanceConsole’s Quick Setup lets you easily configure the PBX to receive intercom and trunk calls, as well as applybasic settings such as time and date.

    To programme the PBX, connect it to the PC via the MNT or RS-232C port.

    PC ConnectionMNT Port

    To LAN Port

    To COM Port

    RS-232C Port

    PC

    PC

    To attach the ferrite core

    3 cm

    Pin AssignmentsRS-232C (Cross Cable)

    Pin No.

    2

    34

    56

    78

    Pin No.

    2

    34

    56

    78

    RS-232C PortCOM Port

    Pin No.

    1

    2

    3

    6

    1

    2

    3

    6

    Pin No.

    LAN (RJ45 Cable)

    LAN Port (PC) MNT Port (PBX)

    CAUTIONWhen connecting a PC to the PBX via the RS-232C port, it is necessary to keep the following in mind toprotect the system:1. Make sure that both connector cases (frame ground) of the RS-232C cross cable (shielded cable) are

    conductive. If they are not conductive, make sure that both connector cases of the cable are firmlyconnected.

    2. If this is not possible, connect the frame of the PBX to the frame of the PC using an earthing wire inorder to prevent difference in the electrical potentials.

    NoticeWhen connecting a PC to the PBX via the MNT port, a fixed IP address must be assigned to the PC. Forinformation about fixed IP addresses, ask your network administrator.

    Getting Started for Physical Cards 21

    3.2 Connecting the PC

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 3.3 Installing the Maintenance ConsoleFor the system requirements of the PC (e.g., operating system, hardware specifications), refer to"4.3.1 Installing and Starting the Maintenance Console" in the Installation Manual.

    Note• Make sure to install and use the latest version of the Maintenance Console.• The contents and design of the software are subject to change without notice.• Microsoft product screen shot(s) reprinted with permission from Microsoft Corporation.

    1. Copy the setup file of the Maintenance Console to your PC.2. Double-click the setup file to run the installer.3. Follow the on-screen instructions provided by the installation wizard.

    22 Getting Started for Physical Cards

    3.3 Installing the Maintenance Console

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • Section 4

    Programming

    Getting Started for Physical Cards 23

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 4.1 Programming the PBXStarting the Maintenance Console and Assigning the Basic Items (QuickSetup)

    When you start the Maintenance Console with the Installer Level Programmer Code and connect to the PBXfor the first time after initialisation (with the factory default setting), Quick Setup will launch automatically. DuringQuick Setup, you will set up the basic items. For details about the basic items, refer to "2.3.4 Quick Setup" inthe Feature Guide.

    1. Connect the PC to the PBX with an Ethernet straight cable or RS-232C cross cable.

    2. Start the Maintenance Console from the Start menu.

    3. "Information before programming" appears.a. Carefully read this important additional information, which includes updates to this and other

    manuals.b. Click OK to close this window.

    4. a. Enter the Installer Level Programmer Code (default: INSTALLER).b. Click OK.

    5. Click Connect.

    6. a. Select KX-TDE100/200 from PBX Model.b. Select the LAN or RS-232C tab, depending on the type of PC connection with the PBX.c. Specify the settings as required.

    NoteWhen connecting to the PBX for the first time selecting LAN, the IP Address and PortNumber must be set to 192.168.0.101 and 35300 respectively.

    d. Enter the system password for installer (default: 1234).e. Click Connect.

    7. When country/area data do not match:a. Click OK to replace the country/area data of the PBX. Replacement may take several minutes to

    complete.b. Follow the procedure described in "Section 3 Before Programming" and restart the PBX.c. Repeat step 5 to reconnect the Maintenance Console to the PBX.

    8. Follow the instructions of the Quick Setup wizard and assign the basic items (Quick Setup).The system menu appears. You may now begin programming the PBX.

    24 Getting Started for Physical Cards

    4.1 Programming the PBX

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • Assigning the BRI Setting (Automatic Configuration)1. a. Under Configuration, click Slot.

    b. Move the mouse pointer over the BRI card.A menu will be shown under the mouse pointer.

    c. Click Ous to set the card to out-of-service status.

    2. Click Tool ® BRI Automatic Configuration from themenu bar.

    3. a. Click Check to turn on the BRI card.b. Click OK.

    4. a. Enter the subscriber number for the desired ports inSubscriber.

    b. Click Execute.

    NoteNetwork settings are automatically set.

    c. Click Check Box of the desired ports.d. Click Data Apply.e. Click Close.

    5. a. Under Configuration, click Slot.b. Move the mouse pointer over the BRI card, then click

    INS to set the card to in-service status.

    Getting Started for Physical Cards 25

    4.1 Programming the PBX

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • Assigning the Incoming Trunk Call DestinationFor analogue trunk users (DIL Setting):

    1. Under CO & Incoming Call, click DIL Table & PortSettings.

    2. Confirm that the DIL tab is selected.

    3. Configure the settings as required.

    4. Click OK.

    For ISDN trunk users (DDI Setting):

    1. Under CO & Incoming Call, click DDI / DID Table.

    2. Configure the settings as required.

    3. Click OK.

    For ISDN trunk users (MSN Setting):

    1. Under CO & Incoming Call, click DIL Table & PortSettings.

    2. Click the DDI / DID / TIE / MSN tab.

    3. Set the Distribution Method of the desired ports toMSN.

    4. Click OK.

    5. Click MSN Table.

    6. Click the MSN tab.

    7. Configure the settings as required.

    8. Click OK.

    26 Getting Started for Physical Cards

    4.1 Programming the PBX

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • Setting an Extension Port to Use a DSS Console1. Under Configuration, click Slot.

    2. Move the mouse pointer over the desired extensioncard to display the menu of options.

    3. Click Ous to set the card to out-of-service status.

    4. Move the mouse pointer over the card again, then clickPort Property.

    5. For DPT Type, set the Type to DSS and assign theLocation No.

    6. Click OK .

    7. Under Extension, click DSS Console.

    8. Select the desired pair extension number from PairExtension.

    9. Assign features to flexible buttons as required.

    10. Click OK.

    11. Under Configuration, click Slot.

    12. Move the mouse pointer over the card to display themenu of options.

    13. Click INS to set the card to in-service status.

    14. Click Close.

    Getting Started for Physical Cards 27

    4.1 Programming the PBX

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 28 Getting Started for Physical Cards

    4.1 Programming the PBX

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • Section 5

    Confirming the Connection

    Getting Started for Physical Cards 29

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 5.1 Making and Receiving CallsMaking Calls

    To call another extension

    Off-hook. Talk.Dial extension number.

    extension no.

    To call an outside party

    Off-hook. Talk.Dial outside phone number.

    Enter automatic line access number.

    outsidephone no.9 0/

    Receiving Calls

    Off-hook. Talk.

    30 Getting Started for Physical Cards

    5.1 Making and Receiving Calls

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • The KX-TDE100UK/KX-TDE200UK, the KX-TDE100NE/KX-TDE200NE, the KX-TDE100GR/KX-TDE200GR,

    and the KX-TDE100CE/KX-TDE200CE are designed to interwork with the:

    • Analogue Public Switched Telephone Network (PSTN) of European countries

    • Pan-European Integrated Services Digital Network (ISDN) using ISDN basic rate access

    • Pan-European Integrated Services Digital Network (ISDN) using ISDN primary rate

    access

    • ONP 2048 kbit/s digital structured leased lines (D2048S)

    Panasonic System Networks Co., Ltd. declares that this equipment is in compliance with the essential requirements and

    other relevant provisions of Radio & Telecommunications Terminal Equipment (R&TTE) Directive 1999/5/EC.

    Declarations of Conformity for the relevant Panasonic products described in this manual are available for download by

    visiting:

    http://www.ptc.panasonic.eu

    Contact to Authorised Representative:

    Panasonic Testing Centre

    Panasonic Marketing Europe GmbH

    Winsbergring 15, 22525 Hamburg, Germany

    WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ptc.panasonic.euhttp://www.ertebatgroup.comhttp://www.ertebatgroup.com

  • 1-62, 4-chome, Minoshima, Hakata-ku, Fukuoka 812-8531, Japan

    PSQX4416TA

    Copyright:

    This material is copyrighted by Panasonic System Networks Co., Ltd., and may be reproduced for internal use

    only. All other reproduction, in whole or in part, is prohibited without the written consent of Panasonic System

    Networks Co., Ltd.

    Panasonic System Networks Co., Ltd. 2010

    KK0607CH6053WWW.ERTEBATGROUP.COM

    WWW.ERTEBATGROUP.COM

    http://www.ertebatgroup.comhttp://www.ertebatgroup.com

    Table of Contents1 Before Installation1.1 Safety Notices1.2 System Connection Diagram1.3 Unpacking

    2 Installation2.1 Opening/Closing the Front Cover2.2 Inserting the SD Memory Card to the IPCMPR Card2.3 Installing the Option Units2.4 Installing the Trunk Cards2.5 Installing the Extension Cards (DLC8/DLC16/DHLC8/MSLC16/SLC8/SLC16/CSLC16)2.6 Connecting Extensions2.7 Frame Earth Connection

    3 Before Programming3.1 Starting the PBX3.2 Connecting the PC3.3 Installing the Maintenance Console

    4 Programming4.1 Programming the PBX

    5 Confirming the Connection5.1 Making and Receiving Calls