Gem Batteries has launched a wide range of tubular batteries to offer its customers with reliable, consistent and low maintenance power for meeting different types of energy requirements. These batteries can be subjected to heavy-duty and are capable of supporting rural and power deficit areas conveniently. Gem has specifically developed its range of tubular batteries keeping in mind the increasing demand in high-tech and smart batteries.
Citation preview
Tubular Monobloc Heat Sealed
Polypropylene Batteries
GEM Tubular Batter ies are manufactured with Heat Sealed Polypropylene Co Polymer Monobloc casing mater ia l .
Tubular posit ive plates are made of highly corrosion-resistant special lead al loy and Pasted Negative Plates with
high discharge performance to ensure cycl ing capabi l i t ies and also reduce topping-up frequency. Individual cel ls
are fitted with Micro Porous aqua-trap ceramic vent plugs with sealed float, which prevent acid mist coming out from
the cells to make it convenient for living room ambience.
UPS Systems
Inverters
Alarm Systems, EPABX
Emergency Lighting
Switchgear Operations
Solar Photovoltaic & Wind Power
Genset Starting
UPS for Banks & ATM Counters
Communication Networks
•
•
•
•
•
•
•
•
•
PRODUCT FEATURES
•
•
•
•
•
•
•
•
•
7 years life on cycling duty
Tubular positive plates
Dry charged battery
Ceramic vent plugs with sealed float
Heat sealed polypropylene casing
No acid fumes, eco-friendly
Reduced topping-up frequency
Heavy-duty terminals
Abuse resistant
APPLICATIONS
BATTERYT U B U L A R
BATTERY
TM
CAPACITY WEIGHTS AND DIMENSIONS
TYPEC10
Capacity(AH)
NominalVoltage
(V)
WithoutAcid + 5%
Lmm
Wmm
H*mm
ConstantCurrent Charge
(Amps)
Battery Weight Overall Dimensions in (mm) + 3mm Trickle Charge Current (mA)
Min Max
GTL - 20
GTL- 40
GTL - 75
GTL - 100
GTX - 600
GTX - 800
20
45
75
100
120
140
12
12
12
12
12
12
10.350
15.450
21.900
26.700
31.700
36.400
16.800
24.000
39.000
42.000
52.300
56.400
305
414
522
522
515
515
170
175
220
220
275
275
230
235
251
251
255
255
2.5
4.5
7.5
10.0
12.0
14.0
20
40
75
100
120
140
80
160
300
400
180
560
CAPACITY WEIGHTS AND DIMENSIONS
TYPEC10
Capacity(AH)
NominalVoltage
(V)
WithoutAcid + 5%
Lmm
Wmm
H*mm
ConstantCurrent Charge
(Amps)
Battery Weight Overall Dimensions in (mm) + 3mm Trickle Charge Current (mA)
Min Max
GTX - 5500
GTX- 10000
GTX - 15000
120
160
200
12
12
12
31.5
42.3
53.1
55.8
66.2
76.1
465
465
465
177
177
177
375
375
375
12.0
16.0
20.0
120
160
200
480
640
800
With Acid 5%+
With Acid 5%+
DESIGN EXPECTATION RATED CAPACITIES AT 27°C in Ah
Discharge Rate 20 Hr. 10 Hr. 5 Hr. 3 Hr. 1 Hr.
Cut-off Voltage 10.50 V 10.50 V 10.50 V 10.50 V 10.50 V
GTL - 20 25 20 16 14 10
GTL - 40 60 45 40 34 24
GTL - 75 94 75 61 53 37
GTL - 100 125 100 79 68 47
GTX - 600 150 120 101 87 60
GTX - 800 175 140 118 102 70
Discharge Rate 20 Hr. 10 Hr. 5 Hr. 3 Hr. 1 Hr.
Cut-off Voltage 10.50 V 10.50 V 10.50 V 10.50 V 10.50 V
GTX - 5500 150 120 94 81 56
GTX - 10000 200 160 136 118 81
GTX - 15000 250 200 181 156 105
Tubular Plate Monobloc Heat
Sealed Polypropylene Batteries
GEM Tubular Plate Batteries are specially designed for inverter applications and are made with ultra-thick charged plates for long life & performance. They
are user-friendly batteries with quick initial charging capability, very low internal resistance, and have a steady voltage profile during short & long duration
discharges. The sealed float and ceramic filter plugs help easy maintenance of electrolyte level and ensure no fume emissions. These batteries have a great
charge acceptance and retention properties even in arduous working conditions.
Initial Filling and Charging Instructions•
•
•
•
•
Fill battery grade sulphuric acid in all the cells up to the required levels
Filling Specific Gravity: 1.220 +- 0.005 at 27°C
Fully Charged Gravity: 1.250 +- 0.005 at 27°C; adjust final working gravity in all the cells
Charge the batteries with constant current as indicated in the table, after 2 hrs. of soaking period, until the top of charge voltage reach 16.20
Volts per battery
Conditions of fully charged:
a) 3 consecutive hourly readings of specific gravity and voltage become constant b) Top of charge voltage will be around 16.2 V – 16.5 V
c) All cells should be gas-free d) Minimum Ah has been given
BATTERY SELECTION CHART
LOAD
Fans
1
1
2
2
3
5
8
12
Lights
1
2
2
4
4
5
10
14
RecommendedInverter (Watt)
150-200
200-250
300-350
400-450
500-550
800-850
1400-1500
2000
12
12
12
12
12
12
12
12
BACK UP
Battery Volt 5/HRS 3/HRS 2/HRS 1/HRS
GTL 100
GTX-5500, GTX-600
GTX-800
GTX-15000
2xGTX-800 (P)
2xGTX-15000 (S)
2x2xGTX-15000 (S,P)
4x4xGTX-800 (S,P)
GTL 75
GTL 100
GT 5 00, 600X- 5 GTX-
GT 10000, 800X- GTX-
GTX-15000
2x 800 (S)GTX-
2x2xGTX-800 (S,P)
4xGTX-15000 (S)
GTL 40
GTL 75
GTL 100
GT 5 00, 600X- 5 GTX-
GT 10000, 800X- GTX-
2x 600 (S)GTX-
2x 15000 (S)GTX-
4x 800 (S)GTX-
GTL 40
GTL 40
GTL 75
GTL 100
GT 5 00, 600X- 5 GTX-
2x 100 (S)GTL-
2x 800 (S)GTX-
4x 100 (S)GTX-
S = Series Connection; P = Parellel Connection
BATTERYT U B U L A R