4
Save time and money, plus increase home value! Technical Flyer The new Murray Generator Ready Load Center can save thousands of dollars in future generator installation expenses while keeping initial expenses to a minimum. Works with an automatic standby generator or a portable generator. Load Center Features: J UL Listed J Indoor Type 1 J 225A max rated J Flush or surface mounting J Fits between standard stud centers J Tin plated copper bus bars J 22 kAIC rated J 120/240V ~, 1X J Panels convertible between main lug and main breaker J Installation of transfer mechanism can be performed at time of generator installation Automatic Transfer Switch Features: J UL Listed J Operates automatically when connected to generator J Transfers load from utility to generator and back to utility Catalog Numbers: LC3042B1200GEN LC3042L1225GEN GENTFRSWTCH (auto transfer switch) ECSBPK01 (mechanical interlock) generator ready

generator ready...power, and 18 spaces / 30 circuits are backed up by the generator. The generator ready load center is compatible with Siemens, Generac, Guardian, and Centurion type

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: generator ready...power, and 18 spaces / 30 circuits are backed up by the generator. The generator ready load center is compatible with Siemens, Generac, Guardian, and Centurion type

Save time and money, plusincrease home value!

companies. Speciヮcations are subject to change without notice.

Te

ch

nic

al

Fly

er

The new Murray Generator Ready Load Center can save thousands of dollars in future generator installation expenses while keeping initial expenses to a minimum. Works with anautomatic standby generator or a portable generator.

Load Center Features:

J UL ListedJ Indoor Type 1J 225A max ratedJ Flush or surface mountingJ Fits between standard stud centersJ Tin plated copper bus barsJ 22 kAIC ratedJ 120/240V ~, 1XJ Panels convertible between main lug and main breakerJ Installation of transfer mechanism can be performed at time of generator installation

Automatic Transfer

Switch Features:

J UL Listed J Operates automatically when connected to generatorJ Transfers load from utility to generator and back to utility

Catalog Numbers:

LC3042B1200GENLC3042L1225GENGENTFRSWTCH (auto transfer switch)ECSBPK01 (mechanical interlock)

generator ready

switch installed in ヮeld

a

installed in the ヮeld

b

a

b

Page 2: generator ready...power, and 18 spaces / 30 circuits are backed up by the generator. The generator ready load center is compatible with Siemens, Generac, Guardian, and Centurion type

Utility

only

circuits

S

SS

Critical circuits

(powered by

utility and

generator)

Features

Instead of having one interior like standard load centers, theMurray generator ready load center has two interiors. During normal operating utility conditions, both interiors are powered. During generator back up conditions, only thelower interior containing critical circuits is powered.

Since standby generators are hard wired into the home’s electrical system, and plumbed into the natural gas or propane supply, installing them after the home construction is complete can be costly and time consuming.

During construction, a Murray generator ready load center can be installed eliminating the need for future rewiring. Pre-planning on the builder’s part should also include running a gas line to the future generator site, and installing a junction box.

The generator ready load center has a total of 30 spaces / 42 circuits. All 30 spaces / 42 circuits are powered by utility power, and 18 spaces / 30 circuits are backed up by the generator.

The generator ready load center is compatible with Siemens, Generac, Guardian, and Centurion type standby generators up to 30 kW in size, and any brand of portable generatorup to 125A in output.

The majority of standby generator installations are

major extended power outages in the area trigger generator

J

J

- Power leads (D) run to junction box (E)

range from $1,500 to $5,000 for most typical retroヮt

J

- Power leads (B) run to junction box (C)

J

signiヮcantly cheaper than an automatic transfer switch. The ヮnal installation uses fewer components making better

a

J

J

a

Visit www.sea.siemens.com/generators for more information on Siemens Standby Generators including model numbers, manuals, contractors and cut sheets.

LC3042L1225GEN

Install ECSBPK01

for portable

generators

Install GENTFRSWTCH

for automatic standby

generators

Page 3: generator ready...power, and 18 spaces / 30 circuits are backed up by the generator. The generator ready load center is compatible with Siemens, Generac, Guardian, and Centurion type

S

AB

C

DF

G

E

S

A

B

D

E

F

CS

A

B

D

E

F

C

A

B

D

E

F

C

A

B

F

C

B

D

EF

C

a junction box.

Traditional Installation

The majority of standby generator installations are performed after home construction is complete. Oftenmajor extended power outages in the area trigger generatorpurchases.

J Existing at time of generator installation: - A wired, whole house load center (A)J Required at time of generator installation: - Automatic transfer switch installed (B) - Back up circuits physically moved to a new back up load center (C) - Power leads (D) run to junction box (E) - Gas line run to the generator site (F) - Generator installed (G)

In such an application, often the load center and gas supplyare not conveniently positioned close to the generator location, requiring extensive electrical work (often behindwalls) and lengthy gas line runs. Installation charges canrange from $1,500 to $5,000 for most typical retroヮt installations. This cost does not include the generator ortransfer switch cost.

Generator Ready Load Center with Automatic Standby Generator Installation:

J Existing at time of generator installation: - Generator ready load center (A) - Power leads (B) run to junction box (C) - Gas lines run to generator site (D)J Required at time of generator installation: - Transfer mechanism installed into generator ready load center (E) - Generator installed (F)

The cost of a generator ready load center is on the same order of magnitude as a regular 40 circuit load center. The transfer mechanism installed inside the load center is signiヮcantly cheaper than an automatic transfer switch. The ヮnal installation uses fewer components making better use of real estate, and making for a much cleaner looking installation.

Portable Generator Installationa:

J Existing at time of portable generator installation: - Generator ready load center (A) - Hard Wiring (B) - Inlet Box (C)J Required at time of portable generator purchase: - Power Cord (D) - Mechanical Interlock (ECSBPK01) (E) - Portable Generator (F)

a The automatic transfer switch should not be used for portable generators.

Page 4: generator ready...power, and 18 spaces / 30 circuits are backed up by the generator. The generator ready load center is compatible with Siemens, Generac, Guardian, and Centurion type

Drawing Layouts

Murray Electrical ProductsSiemens Energy & Automation, Inc.3333 Old Milton ParkwayAlpharetta, GA 30005

[email protected]

www.murrayconnect.com

©2008 Siemens Energy & Automation, Inc. All Rights Reserved.Siemens is a registered trademark of Siemens AG. Murray is a registered trademark of Siemens Energy andAutomation, Inc. Product names mentioned may be trademarks or registered trademarks of their respective companies. Speciヮcations are subject to change without notice.MYFL-GENER-1007 New 0808IN Printed in USA

JJJJJ

JJJ XJ

J

JJ

J

Main Lug unit as shippedwithout automatic transfer

switch installed

Main Lug unit as shippedwithout automatic transfer

switch installed in ヮeld(automatic standby system)

Field installedcontrol wirebreaker (MP215)

Field installedtransfer switch(GENTFRSWTCH)

Field installedgenerator mainswitch (Q2125S)a

View of Main Breakerinstalled on

LC3042B1200GEN

Main Lug unit as shipped,mechanical interlock

(ECSBPK01)installed in the ヮeld

(portable generators)

Mechanical interlock kit ECSBPK01b

Field installedMP typebreaker

(20-125A)

a Q2125S provided with GENTFRSWTCH. For use with automatic

transfer mechanism, the Q2125S must be used. A MP type

breaker is not allowed.

b GENTFRSWTCH is not required for portable generator operation.