Generation Control System for Dominican Republic Power Plant CS7416 APPLICATION PROJECT OVERVIEW Power Generation PRIME MOVERS ENGINE CONTROLS Wartsila engines: 9R32, 12V32, 18V32 Hyundai EMD Woodward AtlasII Integrated Speed, Load and Sequencing controller The Atlas-II control is designed to integrate into modern plant architecture through Ethernet and fieldbus communication protocol for network flexibility and redundancy. Custom software integrates the speed and load control functions. Basler DECS200 Voltage Regulators The DECS 200 offers high performance, high flexibility, and extreme reliability for brushless excited AC synchronous generators. DECS200 is interfaced with the Atlas to maintain kVAr sharing or Power Factor control depending on the connection to the utility grid. HMI Operator Control Panel Human Machine Interface (HMI) touchscreen monitor displays local engine / generator data, including engine pressures and temperatures, automatic synchronizing to the bus, KW load sharing, KW baseload control, KVAr sharing or power factor control, manual operation of generator loading from HMI Operator Panel, Alarm and Shutdown logging. Governor Control Systems, Inc. (GCS) was contracted to update the old control system of a power plant for a major resort area in the Dominican Republic. The obsolete equipment was expensive and difficult to maintain, putting the resort at risk of blackouts. The HMI system was running on an obsolete Windows operating system. GCS replaced the old Modicon PLC, Basler DECS125, and a Woodward 721 with a new Atlas-II fully integrated speed, load, and sequencing control system that provides precise loadsharing and operator diagnostics for the operation. Normal operating mode is droop mode for speed and voltage control when the station runs parallel to another power station which is about 130 km’s away and is connected via a 132 kV line. When in island mode, the plant runs in isoch loadsharing and VAR share mode. The plant consists of a mix of Hyundai, EMD, and Wärtsilä engines of various sizes. GCS replaced the obsolete controls equipment system on all eleven (11) Wartsila engine generator sets and on the three (3) common controls, utilizing the Woodward AtlasII hardware. This proven control greatly increases the reliability and availability of generators. As part of the updated plant controls, GCS provided an integrated Supervisory Control and Data Acquisition (SCADA) System for the operations control room which enables plant operators to monitor all plant information and react to changing demands at a moment’s notice. PLANT CONTROLS SCADA Operator Station SCADA HMI Operator Station gathers and displays all relevant information available to the AtlasII Controllers. It is a valuable tool for troubleshooting the system and providing clear information on the functions of the control system. Woodward AtlasII Common Engine Controllers Interface to independent protective relays and protection systems Engine Generator upgrade: - Replaced 721, PLC, DECS15 - With AtlasII, RemoteIO, DECS200, HMI, SCADA upgrade Load Control - UT Closed – MW, PF Control - UT Open – MW and MVAr Loadsharing - Auto and manual modes

Generation Control System for Dominican Republic … Studies/CS7416_Generation… ·  · 2017-06-02Generation Control System for Dominican Republic Power Plant CS7416 APPLICATION

  • Upload
    phungtu

  • View
    215

  • Download
    1

Embed Size (px)

Citation preview

Generation Control System for Dominican Republic Power Plant CS7416

APPLICATION PROJECT OVERVIEW

PRIME MOVERS

APPLICATION PROJECT OVERVIEW

Power Generation

PRIME MOVERS

ENGINE CONTROLS

Wartsila engines: 9R32, 12V32, 18V32

Hyundai

EMD

Woodward AtlasII Integrated Speed, Load and Sequencing controllerThe Atlas-II control is designed to integrate into modern plant architecture through Ethernet and fieldbus communication protocol for network flexibility and redundancy. Custom software integrates the speed and load control functions.

Basler DECS200 Voltage RegulatorsThe DECS 200 offers high performance, high flexibility, and extreme reliability for brushless excited AC synchronous generators. DECS200 is interfaced with the Atlas to maintain kVAr sharing or Power Factor control depending on the connection to the utility grid.

HMI Operator Control PanelHuman Machine Interface (HMI) touchscreen monitor displays local engine / generator data, including engine pressures and temperatures, automatic synchronizing to the bus, KW load sharing, KW baseload control, KVAr sharing or power factor control, manual operation of generator loading from HMI Operator Panel, Alarm and Shutdown logging.

Governor Control Systems, Inc. (GCS) was contracted to update the old control system of a power plant for a major resort area in the Dominican Republic. The obsolete equipment was expensive and difficult to maintain, putting the resort at risk of blackouts. The HMI system was running on an obsolete Windows operating system. GCS replaced the old Modicon PLC, Basler DECS125, and a Woodward 721 with a new Atlas-II fully integrated speed, load, and sequencing control system that provides precise loadsharing and operator diagnostics for the operation. Normal operating mode is droop mode for speed and voltage control when the station runs parallel to another power station which is about 130 km’s away and is connected via a 132 kV line. When in island mode, the plant runs in isoch loadsharing and VAR share mode.

The plant consists of a mix of Hyundai, EMD, and Wärtsilä engines of various sizes. GCS replaced the obsolete controls equipment system on all eleven (11) Wartsila engine generator sets and on the three (3) common controls, utilizing the Woodward AtlasII hardware. This proven control greatly increases the reliability and availability of generators. As part of the updated plant controls, GCS provided an integrated Supervisory Control and Data Acquisition (SCADA) System for the operations control room which enables plant operators to monitor all plant information and react to changing demands at a moment’s notice.

PLANT CONTROLS

SCADA Operator StationSCADA HMI Operator Station gathers and displays all relevant information available to the AtlasII Controllers. It is a valuable tool for troubleshooting the system and providing clear information on the functions of the control system.

Woodward AtlasII Common Engine Controllers

Interface to independent protective relays and protection systems

Engine Generator upgrade: - Replaced 721, PLC, DECS15- With AtlasII, RemoteIO, DECS200, HMI, SCADA upgrade

Load Control - UT Closed – MW, PF Control- UT Open – MW and MVAr Loadsharing- Auto and manual modes

GCS offers comprehensive control system support, from engine and turbine systems integration to turnkey project management for a broad range of marine, power generation and industrial projects. GCS is a member of the MSHS Group. Learn more at www.govconsys.com or email us at [email protected]

Southeast, Caribbean, Latin America 3101 SW 3rd AvenueFort Lauderdale, FL 33315 Phone: 954-462-7404Toll Free: 877-659-6328Fax: 954-761-8768

Gulf Coast 2022 Tamvest Court Mandeville, LA 70448 Phone: 985-626-8707Toll Free: 888-427-4853Fax: 985-626-8732

Mid-Atlantic 3120 Arizona Avenue Norfolk, VA 23513 Phone: 757-852-5808Toll Free: 877-659-6328Fax: 757-852-5809

Pacific Northwest 3425 16th Avenue West Seattle, WA 98119 Phone: 206-297-0300Fax: 206-297-0302

Generation Control System for Dominican Republic Power Plant CS7416

Engine starting and sequencing Speed control Engine protection and alarming Dead bus operation Automatic synchronizing Automatic kW baseload control Automatic PF control Cooldown and stopSequencing of engine auxiliariesLocal operator alarm / control panel

Engine starting and sequencing Full operational control of generator plant Equipment protection and alarmingDate acquisition for long term historical trending and alarm logging

Control System Overview

Control Functions:

HMI / SCADA Functions: