21
GENERAL TANK DATA CHECKLIST ' TANK NUMBER (?% b& Dot. # 1) Database Current Status Report 2) Database Initial Profile Sheet 3) Tank Location Map 4) Tank Location Photographs ' Revised 2/l/91 Received d i4 x x

GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

  • Upload
    vuquynh

  • View
    241

  • Download
    14

Embed Size (px)

Citation preview

Page 1: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

GENERAL TANK DATA CHECKLIST '

TANK NUMBER (?% b&

Dot. #

1) Database Current Status Report

2) Database Initial Profile Sheet

3) Tank Location Map

4) Tank Location Photographs

' Revised 2/l/91

Received

d

i4

x

x

Page 2: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

INEL UNDERGROUND STORAGE TANKS

:RAL TANK INFORMATION & 37-2 5

TANK ID: 680 COCA NUB: CFA-36 OTHER TANK NUB:

FACILITY: CFA BUILDING NUB: 680 IDAHO NO.

AREA: DRAWING NUM: STOCK NO. INVEN LOC:

DOE CONTRACTOR: EG&G 1 TANK OWNER: K.R. THURMAN OWNER PHONE: 6-2830

CONTACT NAME: D.K. LAINBART CONTACT PHONE: 6-2492 I

TANK STATUS

TANK TYPE: UST AGE 1988: 37 EMPTY:

CONTENTS: GASOLINE TYPE OF CONT: PETROLEUM DIA.:

CAPACITY/GALLONS: 55 REMAINING GALS: DEPTH: 1' 3"

LAB RESULTS: SAMPLED DATE:04/20/90 DEFERRED: N/A

CURRENT STATUS: OUT-OF-SERVICE FUNCTION: UNKNOWN GALS REMVD: 0

DATE REMOVED:iollulQo zti

DATE INSTALLED: 1951 DATE LAST USED: 1983 EMPTIED DATE:

280: ? L

CONSTRUCTION

CONSTRUCTION MATERIAL: UNKNOWN PIPING MATERIAL: GALV. STEEL

PIPING TYPE:

PROTECTION

INTERNAL PROTECTION: UNKNOWN EXTERNAL PROTECTION: UNKNOWN

DETECTION

1 DETECTION NOTES:

I MISC. INFO.

I NOTES:

Page 3: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

INEL TANK DATA3ASE FORM

Directions for form use: Fill in the blanks with appropriate information and/or highlight the essential information contained between commas. The end result will be a computerized tank database.

lank Owner: DOE-ID Facility: CFA Tank Number &FA-6%2, A/. Responsible Person: CFA Landlord .Phone No. 526-2830

Tank Volume: ST gallons Date Installed: /qa-/ Source of Date:

EPA Regulated Under: UST. Hazardous Waste, Radioactive Waste. Not Requlated

Tank Reported to EPA: No, Not Required, Yes - Date:

Contents: Unknown, Emotv, Emotv and Clean. No. 2 - Diesel, No. 1 - Diesel'. Reqular Gas. Unleaded Reqular Gas. Suoer Unleaded Gas. Motor Oil, Waste Oil, Solvent ( 1. Hvdraulic Fluid, Aviation Gas jJp-4). Radioactive Waste, Hazardous Waste ( 1% Other ( 1

Function: Unknown, Vehicle Fuel or Oils. Aviation Fuel or Oils. Waste Oil, Heatinq Oil, Emerqencv Generator, Wastewater, Seotic Tank, Sumo. Pesticides. Fertilizer. Electrical Equioment, Flow Throuqh Process Tank, Other 1 L Radioactive Waste ( Hazardous Waste ( 1

Tank Status: In Use, Standbv with Product. Standbv Emotv. To Be Closed, Not Operational After March 1987. On COCA List. Temoorarilv Closed. To Be Removed, Date Removed: To Be Abandoned-in-Place, Date of Abandonment: Inert Fill Material (Unknown, Concrete. Sand, Other Other

1

Construction: Material: Unknown, Carbon Steel, Stainless Steel, Aluminum, Plastic/Fiberqlas. Concrete.

W~all Type: Unknown, Sinqle. Double, Round, Rectansular. Installation: Unknown, Horizontal, Vertical, Covering: Concrete. Asohalt, Gravel, Grass, Earth, Other Notes: Secondarv Containment,

Protection: External: Unknown. None. Asphalt, Plastic/Fiberalas. Paint. Other

Internal: Unknown. None, Eooxv, Other Cathodic: Unknown. None. Anode, Imoressed Current.

Other

Piping System: Type: Unknown. Pressure, Suction, Vaoor Recoverv SVst Material: Unknown. Steel, Coated Steel, Plastic/Fiberqlas

Other cpaacx/ Wall: Unknown. Sinale. Double. Installation: Ooen. Lined. Lined - Leak Detection Eauioment Cathodic Protection:Unknown. None. Anode. Imoressed Current.

1

Page 4: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

INEL TANK DATABASE FOP:1 (Continued - Paqe 21

Tank Drawings: Not Available, Orioinal. As Built. Drawing No.

Tank Dimensions: Diameter Length

Ports: ;;yaY: Unknown, No. Yes, Size At Tank. Remote. Size Locked Cao. Spill/ Overfill Protection,

Gauging: None. Seoarate. Size Vent Pipe: Size

End Design: Unknown, Flat. Hemisoherical, Ellipsoidal. Other

Pumping System: Turbine Pump in Tank, Above Ground Puma, Disoenser Pumo Drop Tube: Unknown. None, Permanent, Removable.

Additional Design/Construction Notes:

Site Location Sketch:

500 GAL. UNDER N.E. QUADRANT

BANDONEDJ, ~~--“

Page 5: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

INEL TANK DATABASE FORM (Continued - Paqe 31

Volume Calibration Chart:

Tank Tightness Tested:

No Chart. Chart Reauired, Chart Not Reauired. Strapping Date: By:

Date: By: Method: Results:

Tank Condition: ;;I;;;;1 Inspection Date: By:

Volume Gauging: Unknown, None, Stick (Dailv, Weeklv. Monthly, ) Mechanical Ball, Float, Taoe. Tape and Ball. Electronic, Automatic Tank Gauqe - Type:

Inventory Control: Input Meter:

Withdrawal:

Deliver Truck, Slick Gauaed. Mechanical Meter. Temperature Compensated Meter. Unknown. None. Mechanical Meter, Temoerature Comoensated Meter,

Inventory Records: None, Yes ( years), Not Reauired, Reauired. Content Level: (Stable, Drops. Raises1 Water Present: (Yes/No) Other Comments:

Leak Detectors: Unknown, None, Internal. External. Interstitial. Tvoe/Brand:

Tank Modifications and Upgrades: Monitoring Equipment: Piping Leak Detection: Spill and Overfill: Corrosion Protection:

Date: Type: Date: Type: Date: Type: Date: Type:

Monthly Monitoring Method: Automatic Tank Gauging with Inventory Control Vapor Monitoring Interstitial Monitoring Other Methods: Pipe Leak Detection Equipment

Page 6: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

INEL TANK OATABASE FORM (Continued - Paqe 41 GENERAL SITE ENVIRONMENTAL INFORMATION

Elevation Above Mean Sea Level:

Groundwater (GW) Depth:

Adjacent Exist GW Monitoring Well:

Groundwater Test Well Required:

Adjacent Surface Water:

Adjacent Underground Utilities:

Adjacent Sensitive Land Use:

Tank Backfill Material

Base Soil pH Factor:

UST Site Soil pH Factor:

Hydraulic Conductivity & Direction:

Specific Resistivity Factor:

Soil Type:

Soil Chemical Concentration:

Product Soil Contamination:

Random DC Current in UST Area:

~-%9&J ft.

-POD to tLo0 ft.

Yes, No, Approx. Distance: ft

Yes, No, To-Be-Determined

None, Lake, River, Stream, Canal Unknown, Other:

Unknown, None, Gas, :Water, Phone, Sewer, Electricity, Other

None, Home, School, Farm, Other:-

Range: 3.9 to 7.0. - Acidic

Range:1X10-3to 2X10-Icm/s to -

to mohms/cm

",;~;~~-$s$.d$~;~e~~~~~ Cl v

Chloride, Sulphide], Other:

Previous, Continued, Visual, Smell Fill Pipe Spill, Groundwater Test, Contamination History:

Unknown, Yes, No, Value: volts.

Page 7: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

NO /

DEPTii OF TANK:

SIZE OF T&NY- . . WIDTH:

!,JP : UCTA;\ik::S

Page 8: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and
Page 9: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

UNDERGROUND STORAGE TAtjK DATA SHEET

,-

I. AREA/LOCATION ......................................... CFA

II. TANK IDENTIFICATION NO. ............................... c*-6sa’“,,

III. OWNER/OPERATOR ........................................ USDOE - ID

A. CONTRACTOR OPERATOR .............. ..i .............. EG&G

1. RESPONSI'BLE DEPT/ORG ........................ ..F& M Landlord

2. CONTACT NAME & PHONE NO. K. R. Thurman -- 6-2830 .............

IV. SYSTEM/SUBSYSTEM NAME AND PURPOSE (BRIEF DESCRIPTION): J-3- gh/lo~ rapw+y z&L= s?-zvui~E 72h! B/2

66 soL/dL , CstiJTE,, -z..sA) our &?f s=mie /.

1983.

v. CONTENTS:

A. PETROLEUM PRODUCTS ONLY ..,...................*..*....... x

8. HAZARDOUS SUBSTANCE (PER CERCLA DEFINITION) ..............

C. HAZARDOUS WASTE (COVERED BY RCRA SUBTITLE C) ............. A"b l?u.&wJ5

Il. RADIOACTIVE MATERIALS (COVERED BY 42 USC 2011,) ...........

'E. MIXTURE OF RCRA SUBTITLE C WASTE AND OTHER REGULATED SUBSTANCES ...............................

F. UNKNOWN .................................................

G. OTHER (EXPLAIN) .........................................

H. EMPTY - PER UST DEFINITION (LIST PRIOR CONTENTS).........

,,, ,,,

Page 10: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

E

E

0 I =:

..-----.- n .-.--- -.--.

Eii

.--

Page 11: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

-.

UNDERGROUND STORAGE TANK L4CATION TANK CFA- 680 b

LOCAT,ION DESCRIPTION: S aa da-l-ail map ‘bcah.

0 Q -‘\-,~k%A:.UtN$:KN.E. QUADRANT

\ \ GASOLINE TANK fARANnnNFi?l

-

Page 12: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

. . .

CFA-36 CFA GASOLINE TANK AT CFA-680 i. .;;,:,, :' :~-

I

Page 13: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and
Page 14: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

,,.

Page 15: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

COMPLIANCE SECTION CtiECKLIST ’

Dot. #

1) State Registration/Notification Form

2) Tank Closure Notice

3) Final Closure Summary

4) Tank Tightness Test Results (if applicable)

5) Release Report Required: YES __ NO ____ Documentation

6) Photographs (if applicable)

Received

$

,!

i

' Revised 2/l/91

Page 16: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

83v 3,me (Csroarauon. Individual. P”blccAgency. arcme, E”!W,

IJ Qeoartment of Enerav. Idaho 00s. Office Street Acoress

?S5 DOE Place 4.d I CJU"2-f /

?onneville '3;tv Clale Z!P cooe

inciiity Name or Comoany Sit,e Idenrifjer. as apqlicaoie Idaho NationaT Englneerlng LaooraTory (INE?) Location: CFA street ADdress or state aoaa. as awicaoie Scoville. Idaho CWXY Butte city ("earall) skxre ZIP csce Arc3 Idaho 93213

I

ntal Scientist Area cme “hone NumDer

(7.08) 526-1508

Page 17: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

LMIE 03113/90 ,HEL llHOERORl”D SIORACE TIWS

,NEL ,lHX ““HBER

WA 606-E,

CFA 606.E2

WA 600

CFA 713-4

CF* 713-5

CfA 731

CPA 735

WA 737

CEA 741-6

WA 741-7

CFA 743

CfA 744

CEA 746

CPA 748-A

Cf* 748-S

CEA 763

STATE Of EURRENI *GE CALLON, COW,. ,Y,ER”lL ENTERHAL PIP,“0 CONIENIS LAS, RENA,” I!IER, ID*“0 “0. SIAI”S 1990 C*P*C,,” MATERIAL PRO,EC. PROIEC. NAUTERIAL USED GAllOHS

‘7 2 b 3 NOBE PA,“,EO TAR COA,EO S,EEL PETROLEUH SASOL,“E 1950

V6 42 10.000 s,h,

3 AN*NDONEo 1950

3 OUI-*F-SER”ICE

I AC,,“E

dwE

i? 10.000 S&EL 5~I ‘f 39 55 “NYNCW” -5, I

39 losooo 5, SF 39

“d/

0,000 STEEL

12,000 ST;EL

59 31 500 S&EL

:+ NONE

Y “NWWN

NOi% ‘5

NOHE 2

LINED 2

NONE

I d COATED STEEL PETROLEWl k ~2

CIILY. STEEL PETROLEUH

I R’ CCNTED STEEL PETROLEUH

i T ft COATED STEEL PETROLE”,,

, !2 R COAIED STEEL PETROLE”,,

T oil Y. STEEL PETROLEUIl

Ik COllIED STEEL PETROLEUM -2

CAL”. STEEL PETROLEU” z

GAL”. STEEL PETROLEW /

STEEL PETROLEUH /

S,EEL PETROLEUM 6

IAN COAIEO STEEL PETROLEW

I DIESEL 1950

GAS% INE 1983

AClfVE I

ACTIVE

ACIlVE

NENTidEO I

PAlhE

*C,,“E

RENZE’,,, 5 REHOVED

CUT-&ER”,CE I

KIIVE t

2”: 2,000 &EL

% I

10.000 STEEL I$“ 30 10,000 &EL

5, 39 2,000 ,I:,,

& 1,000 &EL t2 0 285 SdEL

2; 500 &EL

zi 500 S&L

LINK 15,000 &EL

ACliVE

CUT-G-SERVICE

NdE

? NO E

“ZiE +

UNKNOW

NO?E

NO;E

NLZE

NO& Y

UNKHCUN

PA@

UNKWWN

1 NO E 2

Pk,N,ED z

PA,N,EO 2

PAINTED 5

UNYNCUN

IA k COATED STEEL PETROLEUH

,A 5

COITEO STEEL PETROLE&,

““KNOW PETROLE”,,

“AS Y E OIL ‘/

“ASIE OIL

D,E/,EL

O,E/SEL I

DIESEL

,989

,989

1985

Page 18: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

DA,E 03/13/90 INEL “NDERORWND STORAGE TANKS

,HEL IINL NWSER

CFA “,N SELL 0,

STATE OF CURRENT *oE GAlLONI CONS,. INIERNAL EXIERNAL P,P,NG IDAHO NO. SIAIUS 1990 CAPKIIY HATERIAL PROTEC.

CONIENIS PROTEC.

LAS, REHA,N l”cX,, HA,ER,kL USED CILLO”S

iG ’ ;JU,-OF-SERVKE 15

3 1,000 ,,A,

/ 5 NONE STEEL PETROLEL!” GASOLINE 256

Page 19: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

IDAHO UNOERGROUNO STORAGE TANK 30 Day Notice of Closure Form

Site Owner/Operator: U. S. Deoartment of Enerov. Idaho Ooerations Office Site Address:785 DOE Place Site County: Bonneville Telephone:JPO8) 526-0193 Facility ID (Notification) Number: Fire 0istrict:INEL

Dear Sirs:

In accordance with the Federal UST Regulations, we are notifying you of our intent to permanently close the following underground storage tanks* at the above referenced facility:

TANK* PRODUCT CAPACITY (oals.1 AGE (Years)

CFA 641 Fuel Oil 500 41 CFA 641-Un Gasoline Unknown 61 CFA 656 Fuel Oil 500 66 CFA 667-:i Fuel Oil 1.000 Unknown CFA 667-S Fuel Oil 6,000 Unknown CFA 674-S Fuel Oil 300 Unknown CFA 680 Gasoline 55? 39 CFA 727 Fuel Oil 1.000 37 CFA 740 Fuel Oil 18.000 37 CFA 746 Fuel Oil 285 ARA-I 743 Gasoline 6,000 3: ARA-II 606-NW Fuel Oil 1.000 34 ARA-III 611 Fuel Oil 1,000 14

*Attach additional pages if needed.

We expect this closure to take place on or about November 1 , __ 1990. A site assessment as required by the Federal UST Regulations will be performed before permanent closure is completed.

Please contact John Coodv at (208) 526-1411 if you need any additional information.

Return Completed form to:

UST Coordinator, Water Quality Bureau Idaho Department of Health and Welfare Division of Environmental Quality 450 West State Street Boise, Idaho 83720 Phone: (208) 334-5845

Page 20: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

~hrc: J. E. Coody, MS 8101 0. 6. Engelman, MS 3940 C. N. Hood. MS aI01 R. D. Johnion, M S Gciji L. P. Leach, MS 3940 R. H. Meservey, MS 8101 R. W. Russell, MS 2109 K. R. Thurman, MS 4156 ERP-AROC, MS 3904 UST Project file, MS 8101 I. K. Hall Letter file

October IO, 199C

Mr. J. L. Lyle, Director Environmental Restoration Division Idaho Operations Office - DOE 785 DOE Place Idaho Falls, IO 83402-1118

THIRTY DAY TANK CLOSURE NOTIFICATION - IKH-159-90

Dear Mr. Lyle:

The required 30 Day Notice of Closure Form for the removal of underground storage tanks is attached for DOE-IO signature and transmittal to the State of Idaho. Also attached is a draft letter to be transmitted to Mr. Jarvis.

The underground storage tanks we will be removing are located at Central Facilities Area (CFA), and the Auxiliary Reactor Area (ARA). These tanks were part of the original notification in FY-1989 and this notification is to provide documentation of intent to remove. A. 0. Kirsh, from legal, has reviewed the document and provided concurrence with this action.

If you have any questions, please contact either myself at 526-1806, or J. E. Coody at 526-1411.

Sincerely,

I. K. Hall, Acting Manager, Environmental Restoration Program

JOC:ec

Attachments: As Stated

cc: C. M . Bennett, DOE-IO, MS 1117 W. N. Sato, DOE-IO, MS 1117 J. E. Solecki, DOE-IO, MS 1115 J. 0. Zane, EG&G Idaho (w/o Attach)

Page 21: GENERAL TANK DATA CHECKLIST - US Department of · PDF fileVolume Calibration Chart: Tank Tightness ... Chart Reauired, Chart Not Reauired. Strapping Date: By: Date: By ... Tape and

October 10, 1990

Mr. Rick Jarvis UST Coordinator, Water quality Bureau Idaho Department of Health and Welfare Division of Environmental Quality 450 West State Street Boise, ID 83720

30 DAY NOTICE OF CLOSURE FORMS - JLL- -90

Dear Mr. Jarvis:

Attached please find the completed "30-day Notice of Closure forms", for the INEL. The expected closure date for all of these tanks has been listed as November 1, 1990. This is an anticipated average date based upon the closure schedule for the thirteen tanks over the next two months.

If you have any questions or concerns, please contact J. E. Coody, (208) 526-1411.

Very truly yours,

3. L. Lyle, Director Environmental Restoration Division