General Purpose Thermocouple Temperature Sensors These general purpose sensors can be used in most liquid and air applications. Compression fittings are also available for installation. These probes can be used as stand-alone sensors, or they can be configured with a variety of termination options, and combined with controllers, indicators, or precision thermometers to create complete measurement systems. Specification Sensing Elements: K, J or T to IEC 60 584-2:1995 Accuracy : Class 1 Operating Temperature: from -200 to + 750ºC selection dependant Output: Thermocouple (mV) Cable Type: Selection – PFA-PVC-Fibreglass Accessories Enclosures 4/20mA Transmitters Fittings Controllers Connectors

General Purpose Thermocouple Temperature Sensors · Flying Leads Miniture Plug. Product D. e. scription. Thermocouple with Welded Tip 350°C . Sensor Configuration & Class Maximum

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: General Purpose Thermocouple Temperature Sensors · Flying Leads Miniture Plug. Product D. e. scription. Thermocouple with Welded Tip 350°C . Sensor Configuration & Class Maximum

General PurposeThermocouple Temperature Sensors

These general purpose sensors can be used in most liquid and air applications. Compression fittings are also available for installation. These probes can be used as stand-alone sensors, or they can be configured with a variety of termination options, and combined with controllers, indicators, or precision thermometers to create complete measurement systems.

SpecificationSensing Elements: K, J or T to IEC 60 584-2:1995Accuracy : Class 1 Operating Temperature: from -200 to + 750ºC selection dependantOutput: Thermocouple (mV)Cable Type: Selection – PFA-PVC-Fibreglass

Accessories

Enclosures 4/20mA Transmitters

FittingsControllers

Connectors

Page 2: General Purpose Thermocouple Temperature Sensors · Flying Leads Miniture Plug. Product D. e. scription. Thermocouple with Welded Tip 350°C . Sensor Configuration & Class Maximum
Page 3: General Purpose Thermocouple Temperature Sensors · Flying Leads Miniture Plug. Product D. e. scription. Thermocouple with Welded Tip 350°C . Sensor Configuration & Class Maximum

ModelTCWTCode250C350C750CCodeSKSJSTCodeXXXCodePTFEPVCFGSSOBCodeSCH4ABSLSSBOX7501CodeFLMPSPTB5334A3B5334B3A5331D5337D

TerminationFlying LeadsMiniture Plug

Product DescriptionThermocouple with Welded Tip

350°C

Sensor Configuration & Class

Maximum Operating Temperature °C250°C

750°C

Special Polished Box 100 x 100 x 50 IP65 M20 GlandExd Aluminium Screw Cap Style IP68 M20 Gland

ABS Plastic Enclosure IP65

Single Type T Class 1

Single Type K Class 1Single Type J Class 1

Cable Length in Meters

M20 Gland

Optional Termination Enclosure IP Rating Cable EntryABS Plastic Enclosure IP65 M20 Gland

Specify in MetersCable TypePTFE Cable (Suitable for temperatures up to 250°C)

Fibre Glass Stainless Steel Over Braid (Suitable for temperatures up to 350°C)PVC Cable (Suitable for temperatures up to 105°C)

Ex Rated 2-wire programmable transmitter Universal Input 4/20ma OutputHART 5 or HART 7

Standard PlugCeramic Din Style Termination Block2-wire programmable transmitter Thermocouple Input 4/20ma OutputEx Rated 2-wire programmable transmitter Thermocouple Input 4/20ma OutputEx Rated 2-wire programmable transmitter Universal Input 4/20ma Output

Page 4: General Purpose Thermocouple Temperature Sensors · Flying Leads Miniture Plug. Product D. e. scription. Thermocouple with Welded Tip 350°C . Sensor Configuration & Class Maximum

Sensor Configuration/AssemblyTermination Heads

Type: 5333A

2-wire programmable transmitter5333A– RTD or Ohm input– High measurement accuracy– 3-wire connection– Programmable sensor error value– For DIN form B sensor head mounting

Type: 5333D Type: 5331A3B

2-wire programmable transmitter5333D– RTD or Ohm input– High measurement accuracy– 3-wire connection– Programmable sensor error value– For DIN form B sensor head mounting

2-wire programmable transmitter5331A– RTD, TC, Ohm, or mV input– Extremely high measurement accuracy– 1.5 kVAC galvanic isolation– Programmable sensor error value– For DIN form B sensor head mounting

Type: 7501

Field mounted HART temperature transmitter7501– RTD, TC, Ohm, and bipolar mV input and analog output– High definition local operator interface (LOI) with 3 optical buttons– Selectable red or white backlight– Ex d explosion proof / flame proof– HART 7 functionality with HART 5 compatibility

Type: 5337D

2-wire transmitter with HART protocol 5337D– RTD, TC, Ohm, and bipolar mV input– 2 analog inputs and 5 device variables with status available– HART protocol revision selectable from HART 5 or HART 7– Hardware assessed for use in SIL applications– Mounting in hazardous gas and dust area

Type: 5331D

2-wire programmable transmitter5331D– RTD, TC, Ohm, or mV input– Extremely high measurementaccuracy– 1.5 kVAC galvanic isolation– Programmable sensor errorvalue– For DIN form B sensor headmounting

Full Transmitter Specification Can Be Viewed Via Transmitter Datasheet

Page 5: General Purpose Thermocouple Temperature Sensors · Flying Leads Miniture Plug. Product D. e. scription. Thermocouple with Welded Tip 350°C . Sensor Configuration & Class Maximum

Sensor Configuration/AssemblyTermination Heads

PVC-10C to 105CGood general purpose insulation for mediumtemperature environments. Waterproof andvery flexible.

PTFE-260C to +260CResistant to oils, acids, other adverse agentsand fluids. Good mechanical strength andflexibility.

Silicone Rubber -50 to +200Offers excellent dielectric strength andflexibility. Operation over a widetemperature range and ease of silasticbonding are other outstandingcharacteristics of silicone rubber cable.

Glass fibre(Varnished)-60C to 350CGood temperature range but will notprevent ingress of fluids. Fairly flexible butdoes not provide good mechanicalprotection.

Stainless Steel Flexible Conduitwithstands high temperatures •Durable crush-proof construction•Corrosion and rust resistant

Page 6: General Purpose Thermocouple Temperature Sensors · Flying Leads Miniture Plug. Product D. e. scription. Thermocouple with Welded Tip 350°C . Sensor Configuration & Class Maximum

Inter- national

IEC 584-3

Inter-national

IEC 584-3 Intrin-sically Safe

Farbko-dierun-ANSI Czech

British BS 1843

German Nether-lands

DIN 43710

Japanese JIS C

1610-1981

FrenchNFC

42-324Type Comments Environment -

Bare WireAus-gleichslei-

tung

KClean Oxidising and Inert. Limited use in Vacuum or

Reducing. Wide Temperature range most popular calibration

JReducing, Vacuum, Inert.

Limited Use in Oxidising at high Temperatures not recom-mended for low Temperatures

SOxidising or Inert. Do not

insert in metal tubes. Beware of Contamination. High

Temperature

TMild Oxidising, Reducing Vacuum or Inert. Good

where moisture is present, low Temperature and cryogenic

applications

No standard Use IEC 584-3 Color Codes N Alternative to Type K.

More stable at high Temperatures

ROxidising or Inert. Do

not insert in metal tubes. Beware of contamination. High

Temperature

EOxidising or Inert. Limited

use in Vacuum or Reducing. Highest EMF change per

degree.

No Standard. Use Cop-per Wire

No Standard.

Use Copper Wire

BOxidising or Inert. Do not

insert in metal tubes. Beware of contamination. High Tempe-rature. Common use in glass

industry.

Alloy Combination

Maximum Temperature Useful

Range

EMF (mV)Over Max.Tempera-

ture Range

Limits of Error(Whichever is Greater)

+ Lead - Lead Standard Special

Nickel - Chromium

Ni-Cr

Nickel- Aluminium

Ni-Al (magnetic)

-200 to 1250°C Therm.Grade

0 to 200°C Ext. Grade

-6.458 to 54.886

-200 to 1250°C

2.2°C or 0.75% above 0°C 2.0% below 0°C

1.1°C or 0.4%

± Fe (magnetic)

Copper-Nickel Cu-Ni

0 to 750°C Therm. Grade

0 to 200°C Ext. Grade

-8.095 to 69.553

0 to 750°C

2.2°C or 0.75% 1.1°C or 0.4%

Platinum 10%

Rhodium Pt-10% Rh

PlatinumPt

0 to 1450°C Therm.Grade

0 to 150°C Ext. Grade

-0.236 to 18.693

0 to 1450°C

1.5°C or 0.25% 0.6°C or 0.1%

Copper Cu

Copper- Nickel Cu-Ni

-200 to 350°C Therm.Grade

-60 to 100°C Ext. Grade

-6.528 to 20.872

-200 to 1250°C

2.2°C or 0.75% above 0°C 2.0% below 0°C

0.5°C or 0.4%

Omega-PNicrosil Ni-Cr-Si

Omega-NNisil

Ni-Si-Mg

-270 to 1300°CTherm.Grade

0 to 200°CExt. Grade

-4.345 to 47.513

2.2°C or 0.75% above 0°C 2.0°C below 0°C

1.1°C or 0.4%

Platinum 13%

Rhodium Pt-13% Rh

PlatinumPt

0 to 1450°CTherm.Grade

0 to 150°CExt. Grade

-0.226 to 21.101

0 to 1450°C

1.5°C or 0.25% 0.6°C or 0.1%

Chromega Nickel-

ChromiumNi-Cr

Copper-Nickel Cu-Ni

-200 to 900°CTherm.Grade

0 to 200°CExt. Grade

-9.835 to 76.373

-200 to 900°C

1.7°C or 0.5% above 0°C 1.0% below 0°C

1.0°C or 0.4%

Platinum 30%

Rhodium Pt-30% Rh

Platinum 6%

Rhodium Pt-6% Rh

0 to 1700°CTherm.Grade

0 to 100°CExt. Grade

0 to 13.820

0 to 1700°C

0.5% above 800°C None established