GENERAL NOTES WALL LEGEND ARCHITECTURAL SPECIFICATION ROOFING NOTES SCALE 1:20 @ A3
THESE PLANS HAVE BEEN PREPARED FOR THE SOLE AND EXCLUSIVE USE OF THE CLIENT AND FOR THE ROOF TO BE METAL SHEET AT NOMINATED PITCH IN ACCORDANCE WITH MANUFACTURERS PURPOSE EXPRESSED BY BRAM ARCHITECTS. ANY OTHER PERSON WHO USES OR RELIES ON THESE PLANS SPECIFICATION. WITHOUT THE WRITTEN CONSENT OF BRAM ARCHITECTS, DOES SO AT THEIR OWN RISK AND NO RESPONSIBILITY IS TAKEN BY BRAM ARCHITECTS FOR SUCH USES AND/OR RELIANCE. PROVIDE BOX GUTTERS, RAIN WATER HEADS AND DOWNPIPES AS PER PLANS IN SELECTED COLORBOND
COLOUR. REFER TO ENGINEERS CIVIL DESIGN FOR DRAINAGE WORKS, STORMWATER CONNECTIONS, DO NOT SCALE DRAWINGS - USE WRITTEN DIMENSIONS ONLY. SITE DIMENSIONS ARE IN MILLIMETERS PIPES AND PIT SIZES. UNLESS OTHERWISE STATED.
BUILDER AND BUILDING CONTRACTORS SHALL VERIFY EXISTING SITE CONDMONS, ALL DIMENSIONS, SETBACKS, LEVELS AND SPECIFICATIONS PRIOR TO THE COMMENCEMENT OF ANY SITE WORKS OR ORDER OF MATERIALS.
BUILDER AND BUILDING CONTRACTORS TO ENSURE THAT ALL BUILDING WORKS AND WORKMANSHIP CONFORM TO ALL RELEVANT CODES, THE BUILDING CODE OF AUSTRALIA, A.S. CODES, BUILDING REGULATIONS, LOCAL LAWS AND TOWN PLANNING REQUIREMENTS TO THE SATISFACTION OF THE GOVERNING LOCAL AUTHORMES.
ALL ARCHITECTURAL PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL OR CIVIL ENGINEERING COMPUTATIONS, DRAWINGS, AND SOIL REPORTS
ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE FOLLOWING AUSTRALIAN STANDARDS:
AS. 1288-2006 GI ATE IN BUILDINGS - SELECTION AND INSTALLATION A.S. 1562-2018 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING. A.S. 1684.2-2010 NATIONAL TIMBER FRAMING CODE AS. 1860-2006 INSTALLATION OF PARTICLEBOARD FLOORING A.S. 2047-2014 WINDOWS IN BUILDINGS SELECTIONS AND INSTALLATIONS AS. 2049-2002 ROOF TILES AS. 2050-2018 INSTALLATION OF ROOF TILES A.S. 2870-2011 RESIDENTIAL SLABS AND FOOTING CONSTRUCTION AS. 2904-1995 DAMP PROOF COURSES AND FLASHINGS A.S. 3600-2018 CONCRETE STRUCTURES A.S. 3660.1-2014 PROTECTION OF BUILDING AGAINST SUBTERRANEAN TERMITES. PART 1 NEW
BUILDINGS A.S. 3700-2018 OR AS. 4773.1-2015/ AS. 4773.2-2010 MASONRY STRUCTURES A.S. 3740-2010/ NCC PART 3.8.1 WATERPROOFING OF WET AREA IN RESIDENTIAL BUILDINGS A.S. 3786-2014 SMOKE ALARMS AS. 4100-1998 STEEL STRUCTURES AS. 4256-1994/96 PLASTIC ROOF AND WALL CLADDING MATERIALS A.S. 4055-2012 WIND LOAD FOR HOUSING
THESE NOTES ARE NEITHER EXHAUSTIVE OR A SUBSTITUTE FOR REGULATIONS, STATUTORY REQUIREMENTS, BUILDING PRACTICE OR CONTRACTUAL OBLIGATIONS AND UNLESS NOTED OTHERWISE THEY ARE PROVIDED AS A GUIDELINE AND NO RESPONSIBILITY IS ACCEPTED FOR THEIR USE.
SITE NOTES
BUILDER TO CONFIRM ALL LEVELS ON SITE PRIOR TO CONSTRUCTION. ENSURE THAT NO PART OF STRUCTURE INCLUDING FOOTINGS, WALLS, ROOF AND GUTTERS TO EXTEND BEYOND TITLE BOUNDARY.
SLAB & FOOTING NOTES
SOIL CLASSIFICATION CLASS - REFER TO SOIL REPORT. REFER TO SOIL REPORT AND STRUCTURAL ENGINEER'S SPECIFICATIONS FOR MINIMUM FOUNDING DEPTH AND MAXIMUM ALLOWABLE BEARING PRESSURE.
REFER TO STRUCTURAL ENGINEER'S DRAWINGS FOR DETAILS OF FOOTING LAYOUT, SIZE AND FOUNDING DEPTHS.
THE ENGINEER AND OWNER ARE TO BE NOTIFIED OF ANY VARIATION IN FOUNDATION MATERIAL FROM THAT WHICH IS SPECIFIED.
ALL FOUNDATIONS AND REINFORCEMENT IN FOOTINGS, PADS AND SLABS SHALL BE INSPECTED BY THE BUILDING INSPECTOR PRIOR TO POURING CONCRETE.
REINFORCED CONCRETE WAFFLE SLAB AND APPROVED WATERPROOF MEMBRANE. REFER TO ENGINEER'S DRAWINGS FOR DETAILS AND SPECIFICATION OF SLAB CONSTRUCTION, SAW CUT JOINTS AND CONSTRUCTION JOINT LAYOUTS.
HEALTH & AMENITY
DOORS TO ALL SANITARY COMPARTMENTS TO COMPLY WITH NCC CLAUSE 3.8.3.3 IN THAT THEY ARE EITHER READILY REMOVABLE FROM THE OUTSIDE OF THE COMPARTMENT (LIFTOFF HINGES), SLIDING OR OPEN OUTWARDS.
CIVIL & BUILDING WORKS NOTES
WHERE THE BUILDING (OTHER THAN A CLASS 10a) IS LOCATED IN A DESIGNATED TERMITE INFESTATION AREA, THE BUILDING SHALL BE PROTECTED IN ACCORDANCE WITH THE RELEVANT AUSTRALIAN STANDARD.
SEWER OR SEPTIC SYSTEM SHALL BE IN ACCORDANCE WITH THE RELEVANT AUTHORITIES REQUIREMENTS. FOOTINGS MUST NOT ENCROACH TITLE BOUNDARIES AND EASEMENT LINES.
CONNECT AND DISCHARGE STORMWATER TO LOCAL AUTHORITY REQUIREMENTS. REFER TO CIVIL ENGINEERS DESIGN AND SPECIFICATION. SEWER & WASTE OUTLETS TO BE CONNECTED TO SEWERAGE MAIN AT POINT OF ENTRY. REFER TO ENGINEERS CIVIL WORKS PLAN.
PLUMBING NOTES
HOT WATER SERVICE PLUMBING CONTRACTOR TO INSTALL SELECTED GAS HOT WATER SYSTEM TO THE HOUSE. BUILDER TO CONFIRM LOCATION ONSFTE. HWS TO BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS DETAILS AND SPECIFICATIONS.
SANITARY SERVICES CONNECT NEW SANITARY FIXTURES TO NEW SEWER LINES. CONNECT NEW SEWER LINES TO SEWER MAIN, ALL TO LOCAL COUNCIL REQUIREMENTS.
WET AREAS ALL WET AREAS TO COMPLY WITH PART 3.8.1 AND TABLE 3.8.1.1 OF THE BCA VOL 2 AND A53740-2010 AND EXTERNAL AREAS TO AS/NZS4654.1-2012 AS/NZ54654.2-2012. WALL FINISHES SHALL BE WATER RESISTANT TO A HEIGHT OF 1800MM ABOVE FLOOR LEVEL TO SHOWER ENCLOSURES AND 150MM ABOVE BATHS, BASINS, SINKS AND TROUGHS IF WITHIN 75MM OF THE WALL
TIMBER FLOORS INCLUDING PARTICLEBOARD AND PLYWOOD IN AREAS ADJACENT TO BATHS AND SPAS AND OUTSIDE SHOWER AREAS TO BE WATERPROOFED AS PER PART 3.8.1 BCA VOL. 2 AND AS3740-2010.
GLAZING NOTES
ALL GLAZING TO COMPLY WITH A.S. 1288-2006. EXTERNAL GLAZING TO BE IN ACCORDANCE WITH A.S. 2047-2014
SAFETY GLASS IS TO BE USED IN THE FOLLOWING CASES: 1. ALL ROOMS WITHIN 500MM VERTICAL OF THE FLOOR 2. BATHROOMS WITHIN 2000MM VERTICAL FROM THE BATH BASE 3. LAUNDRY WITHIN 1200MM VERTICAL FROM FLOOR AND/OR WITHIN 300MM HORIZONTAL
FROM ALL DOORS 4. DOORWAY WITHIN 300MM HORIZONTAL FROM ALL DOORS SHOWER SCREENS SHALL BE
GRADE A SAFETY GLASS
WINDOWS SIZES ARE TO BE CONFIRMED ON SITE PRIOR TO THEIR ORDER AND MANUFACTURE. WINDOWS TO BE FLASHED ALL AROUND.
WINDOW OPENINGS IN A BEDROOM THAT IS 2m OR MORE ABOVE THE SURFACE BENEATH AND WHERE THE LOWEST LEVEL OF THAT WINDOW OPENING IS LESS THAN 1.709 ABOVE THE FLOOR, THE OPENABLE PORTION OF THE WINDOW MUST BE PROTECTED WITH A DEVICE TO RESTRICT THE WINDOW OR HAVE A SCREEN WITH SECURE FITTINGS. THE DEVICE OR SCREEN MUST NOT PERMIT A 125mm SPHERE TO PASS THROUGH THE WINDOW OPENING OR SCREEN AND RESIST AN OUTWARD HORIZONTAL ACTION OF 250N.
VENTILATION
MECHANICAL VENTILATION TO BE INSTALLED IN ACCORDANCE WITH PART 3.8.5 OF THE BCA
PROVIDE CLEARANCE FROM UNDERSIDE OF BEARER TO FINISHED GROUND LEVEL OF 150MM FOR FLOOR WITH STRIP FLOORING OR 200MM FOR FLOORS WITH PARTICLEBOARD FLOORING OR 300MM WHERE IN TERMITE PRONE AREA
SUB FLOOR VENTS TO PROVIDE A RATE OF 6000MM SQ. CLEAR VENTILATION PER 1000MM RUN OF EXTERNAL MASONRY WALLS
ARTIFICIAL UGHTING
ARTIFICIAL LIGHTING TO COMPLY WITH AS/NZS1680.0-2009. ARTIFICIAL LIGHTING TO BE INSTALLED IN ACCORDANCE WITH PART 3.12.5.5 OF THE BCA.
ARTIFICIAL LIGHTING TO BE IN ACCORDANCE WITH NCC PART 3.12.5.5.
a. THE LAMP POWER DENSITY OR ILLUMINATION POWER DENSITY OF ARTIFICIAL UGHTING, EXCLUDING HEATERS THAT EMIT LIGHT, MUST NOT EXCEED: • IN A CLASS 1 BUILDING, 5 W/rre; AND • ON A VERANDAH OR BALCONY ATTACHED TO A CLASS 1 BUILDING, 4W/r/°: AND • IN A CLASS 10a BUILDING ASSOCIATED WITH A CLASS 1 BUILDING, 3 W/mz; AND
WHERE ILLUMINATION POWER DENSITY IS USED, IT MAY BE INCREASED BY DIVIDING IT BY THE ILLUMINATION POWER DENSITY ADJUSTMENT FACTOR IN TABLE 3.12.5.3 WHERE APPLICABLE.
WHEN DESIGNING THE LAMP POWER DENSITY OR ILLUMINATION POWER DENSITY, THE POWER OF THE PROPOSED INSTALLATION MUST BE USED RATHER THAN NOMINAL ALLOWANCES FOR EXPOSED BATTEN HOLDERS OR LUMINAIRES.
a. HALOGEN LAMPS MUST BE SEPARATELY SWITCHED FROM FLOURESCENT LAMPS. b. ARTIFICIAL LIGHTING AROUND THE PERIMETER OF A BUILDING MUST:
• BE CONTROLLED BY A DAYLIGHT SENSOR; OR - HAVE AN AVERAGE LIGHT SOURCE EFFICACY OF NOT LESS THAN 40 LUMENS/W.
FIRE SERVICES & EQUIPMENT
SMOKE ALARMS SURFACE WATER TO BE DIVERTED AWAY FROM THE BUILDING, SO THAT THE ADJACENT EXTERNAL SMOKE ALARMS TO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH A.S. 3786-1993 AND PART 3.7.2 OF FINISHED SURFACES SURROUNDING THE BUILDING ARE DRAINED TO MOVE SURFACE WATER AWAY FROM THE BCA AND SHALL BE HARD WIRED WITH BATTERY BACKUP AND INTERCONNECTED. THE BUILDING AND GRADED TO GIVE A SLOPE OF NOT LESS THAN 50mm OVER THE FIRST l m FROM THE BUILDING. THE SMOKE ALARM SYSTEM MUST:
1. BE POWERED FROM THE CONSUMERS MAINS SOURCE STORMWATER & SERVICES 2. BE WITHIN EACH SOLE OCCUPANCY UNIT LOCATED AT THE CEILING IN EVERY STOREY CONTAINING STORMWATER SHALL COMPLY WITH AS/NZ53500.3-2003 BEDROOMS
STORM WATER INCLUDING AGI DRAINS SHALL BE TAKEN TO LEGAL POINT OF DISCHARGE TO THE SATISFACTION OF THE RELEVANT AUTHORITY
EXHAUST FANS INSTALL DRAFT STOPPERS TO ALL EXHAUST FANS
EXTERNAL
INTERNAL
ACCESS & EGRESS
Wi 102mm THICKNESS TIMBER FRAME & K-WALL CLADDING FIRE CRUNCH: SINGLE STUD TIMBER CONSTURCTION
- FIRE CRUNCH K-WALL CLADDING - 12mm THICKNESS (INSTALLATION TO BE IN STRICT ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS)
- HARDIEWRAP WEATHER BARRIER OR APPROVED SIMILAR - 90mm TIMBER FRAMING IN ACCORDANCE WITH A51684 OR A51720.1 (MAX 400mm STUD
CENTRES) - CAVITY INSULATION MIN R2.5 FIRE BATTS - INTERNAL: lx 10mm STANDARD PLASTERBOARD
wa 90mm THICKNESS TIMBER FRAME INTERNAL WALL
- BOTH SIDES: l x 10mm PLASTERBOARD - 90mm TIMBER FRAMING IN ACCORDANCE WITH A51684 OR AS1720.1
NOTF1 ALL WALL SYSTEM TYPES TO BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS REQUIREMENTS.
THRESHOLDS IF THE THRESHOLD SILL OF THE DOORWAY IS GREATER THAN 190MM ABOVE THE FINISHED SURFACE OF THE GROUND TO WHICH THE DOORWAY OPENS, A LANDING SHALL BE PROVIDED NO LESS THAN THE WIDTH OF THE DOOR LEAF, OR 900MM WIDE x 900MM LONG, WHICHEVER IS GREATER.
STAIRS 1. STAIRS, STAIRWAYS AND BALUSTRADES TO COMPLY WITH BCA 39.1 AND 3.9.2.
STAIR REQUIREMENTS: (OTHER THAN SPIRAL STAIRS) RISERS 190MM MAXIMUM, 115MM MINIMUM; GOING 355MM MAXIMUM, 240MM MINIMUM; PRIVATE STAIRS (AND 250MM FOR PUBLIC STAIRS), RISERS AND TREADS TO BE CONSTANT
IN SIZE THROUGHOUT FLIGHT.
2. ENSURE MAXIMUM GAP BETWEEN RISERS NOT TO EXCEED 125MM OR USE CLOSED RISES. PROVIDE CONTINUOUS BALUSTRADE 1000MM MINIMUM.
3. STAIR LANDINGS MUST EXTEND FULL WIDTH AT A DOOR
4. HEIGHT TO BALCONIES AND DECKS WHICH ARE 1000MM OR MORE ABOVE GROUND LEVEL 865MM MINIMUM HEIGHT HANDRAIL ABOVE STAIR NOSING AND LANDINGS.
5. MAXIMUM OPENING BETWEEN BALUSTERS NOT TO EXCEED 125MM.
6. CONTINUOUS HANDRAIL TO BE INSTALLED TO ONE SIDE OF STAIR COMPLIANT WITH PART 3.9.2.4 OF THE BCA 2013
7. WINDOW OPENINGS TO BEDROOMS MORE THAN 2M ABOVE THE SURFACE BENEATH ARE TO HAVE RESTRICTIVE OPENINGS NO MORE THAN 125MM IN ACCORDANCE WITH PART 3.9.2.5 OF THE BCA 2014.1
A BARRIER WITH A HEIGHT OF 865MM ABOVE THE FLOOR TO AN OPENABLE WINDOW IN ADDITION TO THE WINDOW PROTECTION WILL BE PROVIDED WHERE THE FLOOR BELOW THE WINDOW IS 4M OR MORE.
HORIZONTAL OR NEAR HORIZONTAL ELEMENTS BETWEEN 150 MM AND 760MM ABOVE THE FLOOR THAT FACILITATE CLIMBING ARE TO BE INSTALLED WHERE THE SILL HEIGHT IS <865MM ABOVE THE FFL
STAIR TREADS MUST HAVE: -A SURFACE WITH A SLIP-RESISTANCE CLASSIFICATION NOT LESS THAN THAT LISTED IN TABLE 3.9.1.1 WHEN TESTED IN ACCORDANCE WITH A54586-2013; OR
-A NOSING STRIP WITH A SUP-RESISTANCE CLASSIFICATION NOT LESS THAN THAT LISTED IN TABLE 39.1.1 WHEN TESTED IN ACCORDANCE WITH AS4586-2013.
ALL BALCONIES WHICH ARE 1000MM OR MORE ABOVE GROUND LEVEL ARE TO BE PROVIDED WITH PARAPET WALLS OR HANDRAILS WHICH ARE NO LESS THAN 1000MM ABOVE FINISHED FLOOR LEVEL
BUSH FIRE MANAGEMENT - BAL FZ
THE SITE IS WITHIN A BUSHFIRE MANAGEMENT OVERLAY (BMO). REFER TO THE BAL ASSESSMENT REPORT FOR FURTHER DETAILS.
REVISION
• 6.0909 ISSUE FOR INFORMATION
BRAME rchitects PO 00%395 BRUNSMIO, 0403356 m. 0403 425340 0 171093 e90 ama r c h . cts . can
PROJECT
NEW RESIDENCE 95 OLD BEECH FOREST ROAD GELLIBRAND VIC 3239 CUBIT
BAKOS RESIDENCE ORAINIVG TITLE
COVER SCALE JOB NO.
1:20@A3 18-01 DATE
SEPTEMBER 2020
PRELIMINARY DRAWN
MB DRAWING No !REVISION
WDA_00
D20/206566
DP
350 ROOF PITCH
RF1
•
1
PV
PANELS !
PV
PANELS
rPV PANELS
PV
PANELS
PV
PANELS
350 ROOF PITCH
RF1
RF1
5° ROOF PITCH
RF1
35° ROOF PITCH
RF
350 ROOF PITCH
DP
ROOF PLAN SCALE 1:100 @ A3
SITE PLAN SCALE 1:500 @ A3
DP
NO. 105 OLD BEECH FOREST ROAD
10,000LTR RAINWATER TANK FOR FIREFIGHTING. COLORBOND STEEL - COLORBOND MONUMENT
• PV SOLAR PANEL SYSTEM. - DESIGNED BY OTHERS
NO. 85 OLD BEECH FOREST ROAD
01 I. 9 Ai I Al 0 10 MA 000001 Iv IMENIIIIIIMMIIIIIIIN 11 I 11111111 11111111111 11 II 1111 11111111 1 1 11 11 11.1
_
DP
LEGEND DP 100mm DIA COLORBOND DOWNPIPE • COLORBOND - 'MONUMNET
LI COLORBOND CUSTOM ORB ROOF SHEETING - COLORBOND 'MONUMENT - 35° ROOF PITCH
STORMWATER NOTE: BUILDER TO CONFIRM EXTENT AND LOCATION OF DOWNPIPES FOR STORMWATER STORMWATER TAKEN TO LEGAL POINT OF DISCHARGE TO THE SATISFACTION OF THE RELEVANT AUTHORITY.
BOUNDARY NOTE: BUILDER TO ENSURE THAT ALL WORKS ARE LOCATED WITHIN PROPERTY BOUNDARY. WHERE THERE LS AN EXISITNG FENCE ON TITLE, BUILDER TO CONFIRM LOCATION OF PROPOSED WORKS AND ENSURE FENCE LS ERECTED IN THE SAME POSMON.
BUILDING WORKS: NO BUILDING WORKS ARE TO UNDERMINE ADJACENT NEIGHBOURING BUILDINGS. IF ON SITE CONDITIONS ARE SUCH THAT THIS MAY OCCUR THE ENGINEER MUST BE CONTACTED PROMPTLY AND IS TO PROVIDE AMENDED DOCUMENTATION TO THE BUILDING SURVEYOR FOR REVIEW PRIOR TO WORKS CONTINUING
REVISION
- 113.09.20 ISSUE FOR INFORMAlION
BRAmarchitects PO BOX 395 BRUNSVAO, 2103356 m. 0403 425 319 a. nachaakilxamarclaacts.can
PROJECT
NEW RESIDENCE 95 OLD BEECH FOREST ROAD GELLIBRAND VIC 3239 CUBIT
BAKOS RESIDENCE DRANINIG TITLE
SITE & ROOF PLAN SCALE 308 60
1:500, 1:100 A3 18-01 DATE
SEPTEMBER 2020
PRELIMINARY DRAINN
MB DRAINING No REVISION
WDA_01
D20/206566
PLAN LEGEND
23080 3650
90 1820 WO1
3790 MASTER BED
1910
90 //
1820 Wo2
3500 GUEST BED 1
1770
90
1820 WO3
3500 GUEST BED 2
4410
1800 BATH
90
1820 WO4
1150 1820
9950
991 1150 1820
WO5
KITCHEN / MEALS / SITTING
ALFRESCO 3375
125 /150
s f° m cs, m 0, P, e,
DP /
CONCRETE
WO3 DR W1 WO4 -SEE=E
CONCRETE
DO1 EMI
MASTER BED CARPET
GUEST BED 1 CARPET
GUEST BED 2 CARPET
90
SK
ENS TILES 820
WO8
2
PV BATTERY
ROBE
ROBE
CO
820
ROBE
REF
PAN
BATH TILES Li
• DP
1— 1-
-
INLE'T GRILL
DW
1_
MEALS TILES
6540
SITTING TILES
FIRE PLACE .1 FEATURE CONCRETE HEATH/LEDGE
790 000 /I(
000 11
000 11
000 l l
° ° 1
000 / 9°0 1
ISLAND MEALS / SrING 1 241 1
ENS 9C 1 ROBE 90 90 90 2940 850 6330
WO9
241 WRY 90
1
900 003
1 71 BATH CUPD 90 90 90
3620
6
26580
1
1820 1150 1820 WO7 WOE
7450
AC UNIT DP
(W1
1=1
ALFRECO CONCRETE
BUILT IN BBQ
REF :g4707
111000 1 90 7160
W2
2500 BBC) BENCH
GROUND FLOOR PLAN SCALE 1:100 @ A3
AREA ANALYSIS SITE AREA 4742.31 m2
SITE COVERAGE 4% 192.83 m2
GROUND FLOOR 134.44 m2
ALFRESCO 20.88 m.
'/ 150
NOTF1 -ALL EXTERNAL PAVED SURFACES AROUND THE PERIMETER OF THE DWELLING ARE REQUIRED TO GRADE AWAY A MIN. 50mm FOR THE FIRST METRE TO PREVENT PONDING
-CERTIFICATION CON FIRMING ALL WATERPROOFING OF WET AREAS WHICH HAS BEEN CARRIED OUT IN ACCORDANCE WITH BCA PART 3.8.1 AND A53740 IS REQUIRED TO BE SUBMITTED PRIOR TO THE ISSUE OF THE CERTIFICATE OF OCCUPANCY
SA1)LOCATION OF DIRECT WIRED SMOKE ALARM (ON CEILING) IN ACCORDANCE )MTH PART 3.7.2 OF THE B.C.A.
- SMOKE ALARMS MUST BE CONNECTED TO THE CONSUMER MAINS POWER WHERE CONSUMER POWER IS SUPPLIED TO THE BUILDING AND INTERCONNECTED WHERE THERE IS MORE THAN ONE ALARM
0 EXHAUST FAN DUCTED THROUGH TO EXTERIOR
DP 100mm DLA COLORBOND DOWNPIPE • COLORBOND - 'MONUMNET
FW FLOOR WASTE
HWU HOT WATER SYSTEM
DW DISHWASHER
E 300x300 SOLAR SKYLIGHT. EZYLFTE OR SIMILAR
§
It
8
8 0
8
REVISION
• 16.09.09 ISSUE FOR INFORMATION
BRAmarchitects PO BOX 395 BRUNSKICS 9103050 m. 0003 025 319 a. nachaakiaxamarclaacts.con
PROJECT
NEW RESIDENCE 95 OLD BEECH FOREST ROAD GELLIBRAND VIC 3239 CUBIT
BAKOS RESIDENCE ORNNINIG TIlLE
FLOOR PLAN SCALE 308 440
1:100 A3 18-01 DATE
SEPTEMBER 2020
PRELIMINARY SPAWN
MB 55030250 9 0 REVISION
WDA_02
D20/206566
III I
4
A i 1
RF1 RF1 RF1
_ 1!II 11111 [ 1 1 1 1 1, I 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 IIIIIIIIJII'IlrIIII f 1 1 1 1 i I I I 1 • H M I . 1 I 1 I I 1,1 I I I I I I I I ' 1 I cl
_
k \ / FR 1
r % \ / W I \ i FR 1 W1 SI Si I
, Si ‘ Intl SI ' Si SI
,i . , r
F F F
..
F
,
F F ji .
,
F i F F F _I-- —
DP DP DP WO5
NORTH ELEVATION SCALE 1:100 @ A3
DO1 WO4 W03 W02
RF1
_
RF1
— 1 1 1 1 1 I71IIIII 1 1 1 1 i,r I I I I 1 I I I I I I IIIIIIII 1 1 1 1 1 ....
, I i r i I
1 i
__I___!___I___L_I ,
-
( S i
% I 1 I l I , 1 rt FA/7 1 Si
/ / '
' ( .
S1 S1 W1
F .
DP WO8
SOUTH ELEVATION SCALE 1:100 @A3
F R I
- -› I 2T-1rAr Si
F ,--r
02
DO3 12:111
0,
DP
8
MATERIALS & FINISHES SCHEDULE
I — I FIRE CRUNCH - "K-WALL GROOVE BOARD CLADDING" - PAINT FINISH -COLORBOND 'MONUMENT
r r , • COLORBOND CUSTOM ORB ROOF SHEETING - COLORBOND 'MONUMENT' - 35° ROOF PITCH
o_ L a WINDOW & DOOR FRAMES
8
I Si
- ALUMINIUM FRAMING - BLACK POWDERCOAT FINISH
BUSHFIRE BAL FZ WINDOW AND DOOR SHUTTERS - SONNENSCHUTZ BALFZ RATED FIRE SHUTTERS - PAINT FINISH -COLORBOND 'MONUMENT
GUTTERS, DOWNPIPES, FLASHING AND CAPPING - COLORBOND 'MONUMENT
REVISION
• 6.0909 ISSUE FOR INFORMATION
BRAME rchitects PO BOX 395 BRUNSIMIX VC 3058 m. 0103 425 319 e. rOchaolabornerchodo.corn
PROJECT
N E W RESIDENCE 9 5 O L D B E E C H F O R E S T ROAD G E L L I B R A N D V I C 3239
CU ENT
BAKOS RESIDENCE DRAWINIG TI1LE
ELEVATIONS SCALE JOB No.
1:100 A3 18-01 DATE
SEPTEMBER 2020 ISSUE
PRELIMINARY DRAWN
EAST ELEVATION SCALE 1:100 @A3
WEST ELEVATION SCALE 1:100 © A3
MB DRAWING NC5 REVISION
WDA_03
D20/206566
EXTENT OF CONCELAED SCISSOR TRUSSES
I I I I I I I I I I 1 1 1 1 1 1 1 1 1 1
oz$ I— II 00 LU rei II 0 z z Ow 0 0_
....
METAL SHEET FLASHING & CAPPING . . . . . . . COLORBOND- MONUMENT'
- ENSURE WATERTIGHT CONSTRUCTION 1 1 1 1 1 1 1 1 1 1 1 1 1 1 j 1 1 1 1 1 1 PRE-FABRICATED FeissoR TRUSSES TO BE CONSTRUCTED AND INSTALLED AS PER MANUFACTURERS DETAILS. ENSURE THAT TRUSS DESIGN AND COMPUTATIONS ARE SUBM TTED TO RELEVANT BUILDING SURVEYOR FOR APPROVAL PRIOR TO MANUFACTURE
L _1 LI
COLORBOND CUSTOM ORB ROOF SHEETING COLORBOND 'MONUMENT'
1 - 35° ROOF PITCH
1 ic0 IP IF
0 i PRE-FABRICATED SCISSOR TRUSSES TO BE CONSTRUCTED AND INSTALLED AS PER MANUFACTURERS DETAILS. ENSURE THAT TRUSS DESIGN AND COMPUTATIONS ARE SUBMITTED TO RELEVANT BUILDING SURVEYOR FOR APPROVAL PRIOR TO MANUFACTURE
UT =al 111116%7M14=1111M= Isffros,11`47.0.11.611147sTO
ENS TILES
fl r < v '
/PROVIDE 28X28mm GALVANISED STEEL RIGHT : / / ; / < tGD
LA, TCHANNELO CONCRETET O SLAB. UNDERSIDE OF CLADDING
Vars.V...trr"'""`kwr.ro.MERC ."9.1ESTTaTu
ROBE CARPET
EXTENT OF EXPOSED SCISSOR TRUSSES
/ TT imimiwymm:100,
[DRY TILES
BATH TILES
W2
COMMS TILES
rrr 117,7
KITCHEN TILES
WO4
1
R CONCRETE WAFFLE SLAB - REFER TO ENGINEERS DRAWINGS FOR DETAILS 1
//,<<W7/AW//AW//AW//A\
EXTENT OF CONCELAED EXTERNAL SCISSOR TRUSSES
I I I I I I I I I I I I I I I I I I I I I I I PRE-FABRICATED SCISSOR TRI1SSFS TO BE CONSTRUCTED AND INSTALLED AS PER MANUFACTURERS DETAILS. ENSURE THAT TRUSS DESIGN AND COMPUTATIONS ARE SUBMITTED TO RELEVANT BUILDING SURVEYOR FOR APPROVAL PRIOR TO MANUFACTURE
KITCHEN TILES
Ii
El
25mm FOLIBOARD INSULATION & 12mm RECYCLED TIMBER LINING TO UNDERSIDE OF SCISSOR TRUSS.
WO4 1 1
1
1 1 1 1 1 14
11
MEALS TILES
[L
DO1
SITTING TILES
WO5
PROVIDE WATERPROOF MEMBRANE IN ACCORDANCE WITH BCA OVER COMPACTED QUARRY AS REQUIRED
REFER TO ENGINEERS DRAWINGS FOR DETAILS
COLORBOND CUSTOM ORB ROOF SHEETING . . . . . . . . . . . . . . . . . . . . . . - COLORBOND MONUMENT'
- 35 ROOF PITCH
TIMBER FASCIA
W1
W1
DO2
8 1
ALFRESCO CONCRETE
W1
- PAINT FINISH - COLORBOND MONUMENT
PREFABRICATED SCISSOR TRUSSES TO BE CONSTRUCTED AND INSTALLED AS PER MANUFACTURERS DETAILS. ENSURE THAT TRUSS DESIGN AND COMPUTATIONS ARE SUBMITTED TO RELEVANT BUILDING SURVEYOR FOR APPROVAL PRIOR TO MANUFACTURE
EXTERNAL CEILING SYSTEM: - 15mm PLYWOOD - 16mm WATER AND FIRE RATED PLASTERBOARD - 4.5mm CEMENT SHEET LINING - INSTALATION TO BE IN STRICT ACCORDANCE
WITH AS 3959:2018 I
w II 0 z
Lu I-0
.R CONCRETE WAFFLE SLAB - REFER TO ENGINEERS DRAWINGS FOR DETAILS
25mm FOUBOARD INSULATION & 12mm RECYCLED TIMBER LINING TO UNDERSIDE OF SCISSOR TRUSS.
SELECTED LARGE FORMAT PORCELIAN TILES. CONCRETE LOOK.
NOTE: -NATURAL GROUND LINE IS IDICATIVE ONLY.
NOTE' -ALL EXTERNAL PAVED SURFACES AROUND THE PERIMETER OF THE DWELLING ARE REQUIRED TO GRADE AWAY A MIN. 50mm FOR THE FIRST METRE TO PREVENT PONDING
-CERTIFICATION CON FIRMING ALL WATERPROOFING OF WET AREAS WHICH HAS BEEN CARRIED OUT IN ACCORDANCE WITH BCA PART 3.8.1 AND A53740 IS REQUIRED TO BE SUBMITTED PRIOR TO THE ISSUE OF THE CERTIFICATE OF OCCUPANCY
REVISION
• 16.09.20 ISSUE FOR INFORMATION
BRAME rchitects PO BOX 395 BRUNSVAO, VC 3055 m. 0403 425310 5/ r545355593Dramarch15435.039
PROJECT
NEW RESIDENCE 95 OLD BEECH FOREST ROAD GELLIBRAND VIC 3239 CUBIT
BAKOS RESIDENCE DROWNG TIlLE
SECTION A SCALE 308 60
1:50@A3 18-01 DATE
SEPTEMBER 2020 ISSUE
PRELIMINARY DRAWN
PROVIDE WATERPROOF MEMBRANE IN MB
ACCORDANCE WITH BCA OVER COMPACTED DRAWING No REVISION
QUARRY AS REQUIRED - REFER TO ENGINEERS DRAWINGS FOR DETAILS
WDA_04 SECTION A SCALE: 1:50 @ Al
D20/206566
25mm FOLIBOARD INSULATION & 12mm RECYCLED TIMBER LINING TO UNDERSIDE OF SCISSOR TRUSS.
COLORBOND CUSTOM ORB ROOF SHEETING - COLORBOND 'MONUMENT - 35 ROOF PITCH
TIMBER FASCIA - PAINT FINISH - COLORBOND 'MONUMENT - 16mm WATER AND FIRE RATED PLASTERBOARD &
15mm PLYWOOD BEHIND - INSTALATION TO BE IN STRICT ACCORDANCE
WITH AS 3959:2018
EAVES SYSTEM: - 15mm PLYWOOD - 16mm WATER AND FIRE RATED PLASTERBOARD - 4.5mm CEMENT SHEET LINING - INSTALATION TO BE IN STRICT ACCORDANCE
WITH AS 3959:2018
600mm WIDE CONCRETE LEDGE FEATURE - RECYCLED RED BRICKS UNDER (3 COURSES) - PROVIDE A 100mm DROP FACE - PROVIDE STEEL REINFORCEMENT
PROVIDE 28X28mm GALVANISED STEEL RIGHT ANGLE CHANNEL TO UNDERSIDE OF CLADDING AND FIX TO CONCRETE SLAB.
SELECTED LARGE FORMAT PORCELIAN TILES. CONCRETE LOOK.
COLORBOND CUSTOM ORB ROOF SHEETING - COLORBOND 'MONUMENT - 35° ROOF PITCH
TIMBER FASCIA - PAINT FINISH - COLORBOND 'MONUMENT - 16mm WATER AND FIRE RATED PLASTERBOARD &
15mm PLYWOOD BEHIND - INSTALATION TO BE IN STRICT ACCORDANCE
WITH AS 3959:2018
EAVES SYSTEM: - 15mm PLYWOOD - 16mm WATER AND FIRE RATED PLASTERBOARD - 4.5mm CEMENT SHEET LINING - INSTALATION TO BE IN STRICT ACCORDANCE
WITH AS 3959:2018
SELECTED LARGE FORMAT PORCELIAN TILES. CONCRETE LOOK.
PROVIDE 28X28mm GALVANISED STEEL RIGHT ANGLE CHANNEL TO UNDERSIDE OF CLADDING AND FIX TO CONCRETE SLAB.
BALFZ-FIRE ,SHUTTER
SECTION B SCALE: 1:50 @ A3
U_ 49
§ 10
PITCHING
HEIGHT
8 CEILING
HEIGHT
PRE-FABRICATED SCISSOR TRUSSES TO BE CONSTRUCTED AND INSTALLED AS PER MANUFACTURERS DETAILS. ENSURE THAT TRUSS DESIGN AND COMPUTATIONS ARE SUBMITTED TO RELEVANT BUILDING SURVEYOR FOR APPROVAL PRIOR TO MANUFACTURE
COLORBOND CUSTOM ORB ROOF SHEETING COLORBOND MONUMENT
- 35° ROOF PITCH
COLORBOND GUTTER - (INSTALLATION TO BE IN STRICT ACCORDANCE WITH
MANUFACTURERS SPECIFICATIONS) - COLORBOND 'MONUMENT - PROVIDE EMBER GUARD
BUSHFIRE BAL FZ WINDOW AND DOOR SHUTTERS SONNENSCHUTZ BALFZ RATED FIRE SHUTTERS
- PAINT FINISH - COLORBOND MONUMENT
R. CONCRETE WAFFLE SLAB - REFER TO ENGINEERS DRAWINGS FOR DETAILS
PROVIDE WATERPROOF MEMBRANE IN ACCORDANCE WITH BCA OVER COMPACTED QUARRY AS REQUIRED - REFER TO ENGINEERS DRAWINGS FOR DETAILS
PRE-FABRICATED SCISSOR TRUSSES TO BE CONSTRUCTED AND INSTALLED AS PER MANUFACTURERS DETAILS. ENSURE THAT TRUSS DESIGN AND COMPUTATIONS ARE SUBMITTED TO RELEVANT BUILDING SURVEYOR FOR APPROVAL PRIOR TO MANUFACTURE
COLORBOND GUTTER - (INSTALLATION TO BE IN STRICT ACCORDANCE WITH
MANUFACTURERS SPECIFICATIONS) - COLORBOND 'MONUMENT - PROVIDE EMBER GUARD
BUSHFIRE BAL FZ WINDOW AND DOOR SHUTTERS SONNENSCHUTZ BALFZ RATED FIRE SHUTTERS
- PAINT FINISH - COLORBOND MONUMENT
12mm RECYCLED TIMBER LINING TO UNDERSIDE OF SCISSOR TRUSS.
R. CONCRETE WAFFLE SLAB - REFER TO ENGINEERS DRAWINGS FOR DETAILS
PROVIDE WATERPROOF MEMBRANE IN ACCORDANCE WITH BCA OVER COMPACTED QUARRY AS REQUIRED - REFER TO ENGINEERS DRAWINGS FOR DETAILS
NOTE: -NATURAL GROUND LINE IS IDICATIVE ONLY.
NOTE' -ALL EXTERNAL PAVED SURFACES AROUND THE PERIMETER OF THE DWELLING ARE REQUIRED TO GRADE AWAY A MIN. 50mm FOR THE FIRST METRE TO PREVENT PONDING
-CERTIFICATION CON FIRMING ALL WATERPROOFING OF WET AREAS WHICH HAS BEEN CARRIED OUT IN ACCORDANCE WITH BCA PART 3.8.1 AND A53740 IS REQUIRED TO BE SUBMITTED PRIOR TO THE ISSUE OF THE CERTIFICATE OF OCCUPANCY
REVISION
• 113.09.20 ISSUE FOR INFORMATION
BRAME rchitects PO BOX 395 BRuN51,10, 040 3356 m. 0403 425 319 a. nwimelabramarclaacts.can
PROJECT
NEW RESIDENCE 95 OLD BEECH FOREST ROAD GELLIBRAND VIC 3239 CUBIT
BAKOS RESIDENCE (MANIAC TITLE
SECTION B & C SCALE 308 60
1:50@A3 18-01 DATE
SEPTEMBER 2020
PRELIMINARY DRAWN
MB
SECTION C SCALE: 1:50 4, A3
DRAWING No REVISION
WDA_05
D20/206566
1820 3400 MINERAL WOOL OVERSIZED AND COMPRESSED BETWEEN SHEETS AND RIDGE CAPPING
FLOOR LEVEL
FLOOR LE _
EQ EQ
DOI
- GLAZED SWING DOOR WITH FIXED GLAZED PANEL - DOUBLE GLAZING
....
I ULU' /
EQ EQ / /
0 o ,r (NI
0 0 up
, r r r I r r r
r
1 t 14
F F EL
0 8
,,
EQ EQ EQ
- 3 PANEL STACKING SLIDING DOOR - DOUBLE GLAZING
1820
0 8
900
- GLAZED SWING DOOR - DOUBLE GLAZING
850
LO
25mm FOILBOARD INSULATION
ANGLE 35x35x 0.55 BMT MIN
COLORBOND CUSTOM ORB ROOF SHEETING COLORBOND 'MONUMENT
- 35' ROOF PITCH
90x45mm TIMBER BATTENS
75 GLASSWOOL ROOFING BLANKET, LAMINATED WITH LIGHT DUTY REFLECTIVE FOIL CORRUGATED STEEL ROOF SHEETING
15mm PLYWOOD
MINERAL WOOL OVERSIZED AND COMPRESSED INTO ROOF CORRUGATIONS
Z FLASHING
FLEXIBLE FIRE RESISTANT SEALANT
12mm RECYCLED TIMBER LINING
PRE-FABRICATED SCISSOR TRUSSES TO BE CONSTRUCTED AND INSTALLED AS PER MANUFACTURERS DETAILS. ENSURE THAT TRUSS DESIGN AND COMPUTATIONS ARE SUBMITTED TO RELEVANT BUILDING SURVEYOR FOR APPROVAL PRIOR TO MANUFACTURE
16mm WATER AND FIRE RATED PLASTERBOARD
ANGLE 50x50x 0.70 BMT
FIRE CRUNCH K-WALL CLADDING
4.5mm FIBRE CEMENT SHEET EAVES LINING. EXTERNAL PAINT FINISH.
15mm PLYWOOD
ANGLE 35x35x 0.70 BMT
FLEXIBLE FIRE RESISTANT SEALANT
COLORBOND GUTTER - COLORBOND 'MONUMENT' - PROVIDE EMBER GUARD
REVISION
• 6.0909 ISSUE FOR INFORMATION
E I I = 1 Iyl BAL FZ EAVE / ROOF DETAIL IN STRICT ACCORDANCE WITH AS 3959:2018
SCALE: 1:10@AT - AWNING WINDOW WITH FIXED GLAZED PANELS - AWNING WINDOW - DOUBLE GLAZING - DOUBLE GLAZING
WINDOW & DOOR SCHEDULE SCALE: 1:50 @A3
- AWNING WINDOW - DOUBLE GLAZING
ENERGY RATING REQUIREMENTS to,BE READ IN CONJUNCTION WITH ENERGY REPORT PREPARED BY FRATER CONSULTING SERVICES BRAME rchitects ROOF ikCEIUNG INSULATION:
ALL WINDOWS AND EXTERNAL DOORS TO BE ALUMINIUM FRAMED, UNLESS OTHERWISE SPECIFIED. GLAZING TO BE CLEAR, UNLESS NOTED OTHERWISE & TO COMPLY WITH - R5.2 SOLAPB,PAN INSULATED ROOF PANELS. PO BOx 395 BRuNSwICK vC 3358 m. 0403 423310 5/ r5c955493DramarchNcts.con
REQUIREMENTS OF A.S-1288. FLOOR: PROJECT
- WAFFLE POD SLAB'ISQ0mm-85mm) ALL WINDOW HEADS TO BE SET AS NOTED PER SCHEDULE. NEW RESIDENCE SCHEDULE IS TO BE READ IN CONJUNCTION WITH ARCHITECTURAL PLANS. REFER TO
WALL INSULATION: - R3.7 - 140mm INSULWALL PANELS TO ALL EXTERNAL WALLS 95 OLD BEECH FOREST ROAD
PLANS FOR DIRECTION OF DOOR SWING AND SLIDING DOOR DIRECTION. - R2.5 BULK INSULATION IN THE INTERNAL BATH AND LAUNDRY WALLS. GELLIBRAND VIC 3239
REFER ELEVATIONS FOR DETAILS OF DECORATIVE GLAZING BARS, TRANSOM RAILS ETC. WINDOW PERFORMANCE: CUENT
HEIGHTS OF WINDOWS AND WINDOW HEAD LOCATIONS ARE GENERALLY MEASURED FROM AND TO STRUCTURE UNLESS NOTED OTHERWISE.
ALL IMNDOWS AND GLAZED DOORS TO BE ALUMINIUM FRAMED-efOUBLE GLAZED WITH A MINIMUM U VALE AND SHGC AS LISTED BELOW:
BAKOS RESIDENCE ORN/VNG 111LE
- AWNING & CASEMENT WINDOWS - MINIMUM 1,1v.pdx,e6:5-.
& SHGC 0.47 ENSURE THAT ALL WINDOWS AND WINDOW OPENINGS ARE CHECK MEASURED ON SITE PRIOR TO MANUFACTURE - FIXED & SLIDING WINDOWS- MINIMUM U * O E 3.5 & SHGC 0.64 WINDOW / DOOR SCHEDULE & DETAIL
AIR LEAKAGE SCALE JOB No.
ENSURE THAT WINDOWS WHICH EXTEND TO THE UNDERSIDE OF CEIUNGS HAVE THEIR HEIGHTS CHECKED PRIOR TO MANUFACTURE -3.12.3.1 - ALL CHIMNEYS AND FLUES TO BEFITTED WITH SELF CLQSING DAMPERS.
- 3.12.3.2 - ALL ROOF LIGHTS MUST BE SEALED OR CAPABLE TO BE SEALED. 1:50, 1:10 @ A3 18-01
- 312.3.3 - ALL EXTERNAL WINDOWS ArlD DOORS ARE TO BE FITTED WITI-INEATHER-STRIPS. DATE
L WINDOWS AND DOORS TO BE PROVIDED WITH BAL FZ FIRE SHUTTERS - 312.3.4 - SELF-CLOSING DAMPE„Rfo ALL THE EXHAUST FANS.
- 312.3.5 - SEAL ANY AVENUES OF AIR LEAKAGE THROUGH THE BUILDING,,ENVELOPE BY CAULKING, SEPTEMBER 2020 - SONNENSCHUTZ BALFZ RATED FIRE SHUTTERS - PAINT FINISH - COLORBOND 'MONUMENT SKIRTING, ARCHITRAVES :CORNICES OR THE UKE. ISSUE
WINDOW LEGEND F FIXED WINDOW PANEL
EQ EQUAL LENGTH
LIGHTING: - DOWNUGHTS HAVE BEEN INCLUDED IN THIS ASSESSMENT: NO - ALL UGHTIN,G'IN THE DWELLING WILL BE DESIGNED AT 5W/M2 OR BETTER. - ALL LIGKIING ON THE VERANDAH, BALCONY WILL BE DESIGNED AT 4W/M2 OR BETTER. - ALL LIGHTING IN THE GARAGE WILL BE DESIGNED AT 3W/M2 OR BETTER. -
AFIFICIAL UGHT1NG AROUND THE PERIMETER OF THE BUILDING MUST BE CONTROLLED BY A DAYLIG‘K, /SENSOR.
PRELIMINARY DRAINN
MB DRAWING No REVISION
WDA_06
D20/206566
PLAN LEGEND E 300x300 SOLAR SKYLIGHT. EZYUTE OR SIMILAR
SURFACE MOUNTED SOWNLIGHTS FIXED TO TRUSS BOTTOM CHORD. EXACT LOCATION CONFIRMED ON SITE
cn
s , ,_ , - LED STRIP UNDEI4,04HEAD
CUPBOARDS ___ ' E
_ _1-
- - - - - - - - - - - - - -.% - - - - -1 - - - - - - - - - - - - \ WE _ - — - - _ WE ,:._
- - - - - - - - - - - - - •
_ , - - - -_ -_-_ :_-_-_„ ,_ \ WE " ,d o
... 1. 0 ,
B ;
-.' / , POSITION 4 0 / TV / DATA • . IP - - t - r - i 1
-----____-- / . ' OUTLET AT 1569mm \./B I
' , I t ' - - ' - ' - - 4,
'','1?
,-, l
' \ 1 I I I
SK 1 / i /
I , /
(
-
Ii 4
, , !a •
0>
0 0
I I DC
J I /2E
/ I g
f t / AE
I
_ I I
I I
il 1 I
1
I /
7-Ail
i
. _
HiW
, 1
\ •
1 1 AE f
i W l \ .17
., ‘.'' t
I-
W--/ , _ -----
_ \ / %. / - - '
- I
I
_I 0_
POSITION GPO AT 100mm ABOVE LEDGE
1
Itt , ,i _ 1_
0 , \./ / •
LED STRIP UNDER CONCRETE LEDGE - A , _
„ ,.. - • -/ 1 - - ' _ (7-7 -,I...I. _ _ _ , _ 1 . .44i:.E ese57 .E
P, BATTERY
INVI7
ELECTRICAL LAYOUT PLAN SCALE 1:100 @ AS
INOFR TII E HEATING SHOWN SHADED PROVIDE UNDER TILE HEATING TO BOTH THE BATHROOM AND ENSUITE. THERMOSTAT LOCATED NEXT TO THE LIGHT SWITCH
ELECTRICAL METER BOX EXISTING ELECTRICAL METER BOX TO BE RETIANED
BCA PART 3.12.5.5: ARTIFICIAL LIGHTING ARTIFICIAL LIGHTING TO BE IN ACCORDANCE WITH BCA PART 3.12.5.5. a THE LAMP POWER DENSITY OR ILLUMINATION POWER DENSITY OF ARTIFICIAL LIGHTING, EXCLUDING HEATERS THAT EMIT LIGHT, MUST NOT EXCEED: • IN A CLASS 1 BUILDING, 5 W/m0; AND • ON A VERANDAH OR BALCONY ATTACHED TO A CLASS 1 BUILDING, 4W/V ; AND • IN A CLASS 10a BUILDING ASSOCIATED WITH A CLASS 1 BUILDING, 3 W/m2; AND WHERE ILLUMINATION POWER DENSITY IS USED, IT MAY BE INCREASED BY DIVIDING IT BY THE ILLUMINATION POWER DENSITY ADJUSTMENT FACTOR IN TABLE 3.12.5.3 WHERE APPLICABLE
WHEN DESIGNING THE LAMP POWER DENSITY OR ILLUMINATION POWER DENSITY, THE POWER OF THE PROPOSED INSTALLATION MUST BE USED RATHER THAN NOMINAL ALLOWANCES FOR EXPOSED BATTEN HOLDERS OR LUMINAIRES. a HALOGEN LAMPS MUST BE SEPARATELY SWITCHED FROM FLOURESCENT LAMPS. b. ARTIFICIAL LIGHTING AROUND THE PERIMETER OF A BUILDING MUST: • BE CONTROLLED BY A DAYLIGHT SENSOR; OR • HAVE AN AVERAGE LIGHT SOURCE EFFICACY OF NOT LESS THAN 40 LUMENS/W
'PROVIDE POWE9/10 WARM AIR 01,ICTWORK FAN MOTOR,"
-POSITION-01;0 / TV / DATA OUTLET ATbOrnm_ABOVEIEDGE
LED STRIP UNDER OVERHEAD CUPBOARDS
AC UNIT
LOCATION OF DIRECT WIRED SMOKE ALARM (ON CEILING) IN ACCORDANCE WITH PART 3.7.2 OF THE B.C.A.
- SMOKE ALARMS MUST BE CONNECTED TO THE CONSUMER MAINS POWER WHERE CONSUMER POWER IS SUPPLIED TO THE BUILDING AND INTERCONNECTED WHERE THERE IS MORE THAN ONE ALARM
EXHAUST FAN DUCTED THROUGH TO EXTERIOR
c f 10A LIGHTING SWITCH - CLIPSAL ICONIC RANGE - BLACK COVER PLATE
- 2W - DENOTES 2WAY LIGHT SWITCH - 3W - DENOTES 3WAY LIGHT SWITCH - F - WARM AIR DUCTWORK FAN SWITCH
LOW VOLTAGE DIRECTIONAL TRACK LIGHT - 2.4M LONG TRACK - BLACK COLOUR
4 - LED SURFACE MOUNTED/ADJUSTABLE DOWNUGHT A - BLACK COLOUR
AE - DENOTES EXTERNAL
c3 SELECTED WALL LIGHT - BLACK COLOUR • WE - DENOTES EXTERNAL
® FEATURE PENDANT LIGHT - CLIENT TO SELECT
LED UGHTSTRIP LIGHTING - UNDER FEATURE CONCRETE LEDGE - UNDER OVERHEAD CABINTERY
• DOUBLE 10A GPO - CUPSAL ICONIC RANGE AT NOMINAL 300 AFL - BLACK COVER PLATE
A - DENOTES OUTLET AT NOMINAL 1150 AFL B - DENOTES OUTLET AT NOMINAL 1500 AFL C - DENOTES OUTLET AT NOMINAL 750 AFL E - DENOTES EXTERNAL GPO 0 - POWER TO OVEN R - POWER TO RANGEHOOD DW - POWER TO DISHWASHER
SINGLE 10A GPO - SONOS SPEAKER - CLIPSAL ICONIC RANGE AT NOMINAL 300 AFL - BLACK COVER PLATE - CONFIRM HEIGHT ON SITE
( 9 TV OUTLET
V DATA OUTLET
UZI PV POWER INVERTER - CONFIRM LOCATION WITH MANUFACTURE / INSTALLER
I = 1 SWITCHBOARD
REVISION
- 6.0909 ISSUE FOR INFORMATION
BRAME rchitects PO 00%395 BRUNSMIO, 0103056 m. 0403 4253/0 0 //m990-9.1Jramarch.cts.can
PROJECT
NEW RESIDENCE 95 OLD BEECH FOREST ROAD GELLIBRAND VIC 3239 CUENT
BAKOS RESIDENCE DRAWI'JGTIILE
ELECTRICAL LAYOUT PLAN SCALE JOB No.
1:100 g A 3 18-01 DATE
SEPTEMBER 2020 ISSUE
PRELIMINARY DRAINN
MB DRAWING No REVISION
WDA_07
D20/206566