M7 Design Group Pty. Ltd.
cJob No:
Client:
At:F - 03 9317 8119
T - 03 9317 8111
building designers
registered building practitionercopyright 2019: these drawings are not to be copied
01A : 9,61 Wattle RdMaidstone, Vic
WAREHOUSE DEVELOPMENT
LOT 45 APEX DRIVE TRUGANINA
1816 19.09.19
KARANFILOVSKI INVESTMENTS
30.09.19 AS PER SURVEYORS REQUEST
09.10.19 AS PER SURVEYORS REQUEST
KARANFILOVSKI INVESTMENTSAt: 21 APEX DRIVE TRUGANINA, VIC 3029
A01 - COVER SHEETA02 - SITE PLANA03 - GROUND FLOOR PLANA04 - FIRST FLOOR PLANA05 - ROOF PLANA06 - ELEVATIONSA07 - ELEVATIONSA08 - SECTION/WINDOW & DOOR SCHEDULEA09 - DETAILS
FIRE:EMERGENCY LIGHTING EXIT SIGNSARE PORTABLE EXIT. DRY WATERFIRE BLANKETS FOR KITCHENS.
LOT 45 APEX DRIVE TRUGANINA
PROPOSED SIGN PROPOSED SIGN
the agreement and where applicable the Relevant Building Surveyor prior to implementing thesaid variation.
Refer to Civil Engineers design and details for all storm water, car parking and drivewayconstruction requirements.
Refer to fire services design for all hydrant, hose reels and extinguisher details.
Electrical switchboards located in the path of travel to exits to be enclosed in a metal or othernon combustible cabinet with smoke proof doors. Significant switchboards shall be provided witha 5kg carbon dioxide extinguisher or another type of extinguisher with a minimum classificationof 1A:E and fitted with a hose complete with extinguisher identification signage and shall belocated between 2m and 20m from the significant switchboard.
Fire hazard properties of materials and assemblies to comply with BCA Specification C1.10.
Mechanical ventilation or air-conditioning of rooms to be provided with a system complying withAS1668.2 and AS/NZS 3666.1 as amended. Exhaust outlets to be located no closer than 6.0mto fresh air inlets.
Sediment pollution control:-A site management plan is to be implemented during construction to control sediment run-off inaccordance with EPA Victoria publication #275 'construction techniques for sediment pollutioncontrol'.Provide 'propex' or written approved equivalent silt fences to the low side of the allotment andaround all soil stockpiles and storm water inlet pits / sumps and install 'silt stop' filter bags overall storm water entry pits during construction works.'Supergro' or written approved equivalent erosion control fabric to be placed over garden beds toprevent surface erosion during re vegetation period
Personal loading:-Based on sanitary facilities provided per BCA Table. F2.3
Male Employees:-Female Employees:-
Male Patrons:-Female Patrons:-
Male Participants:-Female Participants:-
Children:-
Authorities List:-Municipality-Sewerage authority-Drainage authority-Relevant Building Surveyor-Relevant Fire Authority-Relevant Electrical Supply Authority-
Planning Permit:-Planning Permit No.-Issue Date-Builder to allow for all works to comply and include all required conditions in accordance with thePlanning Permit and shall be responsible that all Planning Conditions are met at the completionof works.
Project Consultants List:-Consulting Structural Engineer-Consulting Civil Engineer-Consulting Fire Service Design-Consulting Land Surveyor-Consulting Geotechnical Engineer-Consulting Landscape Designer-Consulting Mechanical Services Engineer-Consulting Electrical Engineer -Consulting Hydraulic Engineer,Consulting Lighting Designer-
Site geotechnical investigation:-Refer to geotechnical investigation report no. :-By
General Notes for Commercial Works
Revised May 2019
GENERAL NOTES (NCC 2019, BCA Vol 2)
All materials and work practices shall comply with, but not limited to the Building Regulations2019, the National Construction Code series 2019 Building Code of Australia Volume 2 and allrelevant current Australian Standards (as amended) referred to therein.
Unless otherwise specified, the term BCA shall refer to National Construction Code Series 2019Building Code of Australia Volume 2.
All materials and construction practice shall meet the Performance Requirements of the BuildingCode of Australia. Where an alternative solution is proposed then prior to implementation orinstallation it first must be assessed and approved by the Relevant Building Surveyor as meetingthe Performance Requirements of the Building Code of Australia.
Step sizes (other than for spiral stairs) to be:-Risers (R) 190mm maximum and 115mm minimumGoing (G) 355mm maximum and 250mm minimum for Public stairways and 355mm maximumand 240mm minimum for Private stairways2R + 1G = 700mm maximum and 550mm minimumConstructed with a less than 125mm gap to open treads
All treads, landings and the like to have non slip finish or suitable non-skid strip near edge ofnosing.
Provide balustrades where change in level exceeds 1000mm above the surface beneathlandings, ramps and/or treads. Balustrades (other than tensioned wire balustrades) to be:-1000mm minimum above finished surface level of balconies, landings or the like, and1000mm minimum above finished surface level of stair nosing or ramp, andVertical with a less than 125mm gap between, andAny horizontal element within the balustrade between 150mm and 760mm above the floor mustnot facilitate climbing where changes in level exceeds 4000mm above the surface beneathlandings, ramps and/or reads. Top of hand rails to be minimum 865mm vertically above stair nosing and floor surface of ramps.
Window sizes nominated are nominal only. Actual size may vary according to manufacturer.Windows to be flashed all around.
Waterproofing of wet areas to comply with BCA Part F1.7. For buildings in marine or other exposure environments shall have masonry units, mortar and allbuilt in components and the like complying with the durability requirements of AS3700-2011Masonry structures All storm water to be taken to the legal point of discharge to the relevant authorities’ approval. These drawings shall be read in conjunction with all architectural specifications, relevantstructural and all other consultants’ drawings/details and specifications and with any other writteninstructions issued in the course of the contract.
All measurements and levels in millimeters U.N.O. Figured dimensions take precedence over scaled dimensions. The builder shall take all steps necessary to ensure the stability and general water tightness ofall new and/or existing structures and all essential services to be maintained during all works.
The builder and subcontractors shall check and verify all dimensions, setbacks, levels andspecifications and all other relevant documentation prior to the commencement of any works.Report all discrepancies to this office for clarification. Installation of all services shall comply with the respective Supply Authority requirements. The builder and subcontractor shall ensure that all storm water drains, sewer pipes and the likeare located at a sufficient distance from any buildings footing and/or slab edge beams so as toprevent general moisture penetration, dampness, weakening and undermining of any buildingand its footing system.
These plans have been prepared for the exclusive use by the client of [insert Building Designer](‘the Designer’) for the purpose expressly notified to the Designer. Any other person who usesor relies on these plans without the Designer's written consent does so at their own risk and noresponsibility is accepted by the Designer for such use and/or reliance. The approval by this office of a substitute material, work practice, variation or the like is not anauthorisation for its use or a contract variation. Any said variations must be accepted by allparties to
M : 0409 169 993
Proposed: amendmentsdate
concent of the author
in part or in whole with out the written
sheet no:Date:
M7 Design Group Pty. Ltd.
cJob No:
Client:
At:F - 03 9317 8119
T - 03 9317 8111
building designers
registered building practitionercopyright 2019: these drawings are not to be copied
02A : 9,61 Wattle RdMaidstone, Vic
WAREHOUSE DEVELOPMENT
LOT 45 APEX DRIVE TRUGANINA
1816 19.09.19
KARANFILOVSKI INVESTMENTS
30.09.19 AS PER SURVEYORS REQUEST
09.10.19 AS PER SURVEYORS REQUEST
SITE PLANSCALE 1:100
FIRE:EMERGENCY LIGHTING EXIT SIGNSARE PORTABLE EXIT. DRY WATERFIRE BLANKETS FOR KITCHENS.
SITE AREA: 2272m²BUILT UP AREA: 1639.81m²
SITE COVERAGE: 72.17%PERMIBILITY: 11.73%
LEGEND
R/BIN
NOTE:(LEGAL POINT OF DISCHARGE)STORM WATER TO BE CONNECTED
TO LEGAL POINT OF DISCHARGEAS PER LOCAL COUNCIL REQUIREMENTS
LB - LETTER BOX
HWS - HOT WATER SERVICEMB - METER BOX
BIN - RUBISH BINR/BIN - RECYCLE BINHW - HABITAL WINDOW
NHW - NON HABITAL WINDOWGM - GAS METER
RWT - RAIN WATER TANK
LB GM BINHWS RWTMB
NOTE:SOIL TEST(ACE DRILLING)
SITE LEVELS(Home and Industrial Soil Test Pty Ltd)
NOTE:MATERIALS, COLOURS AND TEXTURES ARESELECTED TO HIGHLIGHT THE ARCHITECTURALFORMS AND REFLECT THE ADJACENT DWELLINGS
NOTE:ADJACENT P.O.S TO BE PROTECTED FROMOVER VIEWING WITH A 1800h MIN.COLOURBOND FENCING.
NOTE:BREAK UP LARGE FORMS WITHARTICULATED DIMENTIONS IN PLAN ANDELEVATION, TO MAINTAIN A SCALE RELEVENT TOTHE ADJOINING BUILDING.
REFER TO: HOME AND INDUSTRIAL SOIL TESTINGPLAN OF SURVEY FOR LOCATION OFCONTOUR INTERVALS, BOUNDARIES, FENCES,SURFACE PITS, VALVE COVERS ECT.
NO DIRECT KNOWLEDGE IS CLAIMED OF THE LOCATIONOF UNDERGROUND SERVICES.
PRIOR TO ANY EXCAVATION OR CONSTRUCTION,THE RELEVANT AUTHORITY SHOULD BE CONTACTEDTO LOCATE POSSIBLE UNDERGROUND SERVICES.
GROUND MUST BE GRADED AWAY FROMEXTERNAL WALLS AND SURFACE WATER PROPERLYDRAINED BY MEANS OF SURFACE/CUT-OFF DRAINSCONNECTED INTO SWD VIA SILT PITS
BLOCK BEARINGS MUST BE CONFIRMED PRIOR TOCONSTRUCTION.
ENSURE THAT ALL PRECAUTIONS ARE TAKEN TO PROTECTADJOINING PROPERTY/PUBLIC DURINGEXCAVATION/CONSTRUCTION/DEMOLISHIONOWNERS OF ADJOINING PROPERTY MUST BE CONSULTEDPRIOR TO REMOVING/ALTERING SHARED FENCING
NO PART OF THE PROPOSED STRUCTURE OR FOOTING IS TOENCROACH THE TITLE BOUNDARIES
F.F.L. TO BE CONFIRMED ON SITE BY BUILDING SUPERVISORAFTER COMPLETION OF SITE WORKS.
CONNECT STORMWATER TO LEGAL POINT OFDISCHARGE AS DIRECTED BY LOCAL COUNCIL &AS PER APPROVED DRAINAGE PLAN
SITE TO BE DRAINED TO THE SATISFACTION OFTHE BUILDING SURVEYOR.
CONNECT PVC STORMWATER DRAIN AT1:100 MIN. FALL, WITH INSPECTION OPENINGS AT9M MAX. CTRS. AND AT CHANGE OF DIRECTIONUNLESS NOTED OTHERWISE.
DOWNPIPE LAYOUT MAY VARY ON SITE SHOULD THERELEVANT BUILDING SURVEYOR/COUNCIL REQUIRE IT.
DP: DOWN PIPEDPS: DOWN PIPE WITH SPREADER
DOWNPIPES TO BE PROVIDE AT MAX. 12M CENTRES
PROVIDE A.G. DRAINS WHERE REQUIRED &CONNECT TO S/WATER DRAIN VIA SILT PIT
CONNECT SEWERAGE AS PER RELEVANTAUTHORITY APPROVAL AND TO APPROVEDDISCHARGE POINT. FINAL SEWER PIPE LAYOUTMAY BE ALTERED IF REQUIRED BY RELEVANTSEWER AUTHORITY.
PROVIDE UPVC SEWER PIPE
LOCATION OF SECOND EXTERNAL TAP TO BE DETERMINEDBY POSITION OF OVERFLOW RELIEF GULLY.
CUT / FIL PROPOSALS & FINISHED FLOOR LEVELS ONTHIS SITE PLAN TO BE CHECKED & CONFIRMED PRIORTO CONSTRUCTION BY THE BUILDER / OR SUB-CONTRACTORS.
SITE NOTES:
AD
JO
ININ
G A
LLO
TM
EN
T
9.81
9.83
9.89
9.97
10.2
6
10.2
4
10.17
10.0
6
10
.00
10
.04
TE
LS
TR
AP
ITS
10.0
4
10.2
7
10.5
4
TA
9.80
10.2
0
10.0
8
SE
WE
R P
IT10
.01
(TO
P)
SID
E E
NT
RY
PIT
10
.04(T
OP
)
JU
NC
TIO
N P
IT1
0.1
4(T
OP
)
GR
AT
ED
PIT
9.8
9(T
OP
)
10.2
410
.20
10.3
5
10.3
8
10.4
2
10.2
5
10.1
1
10.4
0
10.4
7
10.6
9
10.5
8
10.5
310
.32
10.6
1
No.2/19
No.1/23
10.2
8
TA
BB
EL
EC
TR
ICIT
Y B
OX
10.0
5( T
OP
)
EL
EC
TR
ICIT
Y P
IT
T.B
.M.
RL 1
0.0
0
NA
IL IN
PA
TH
FO
OT
PA
TH
CO
NC
RE
TE
CO
NC
RE
TE
AP
EX
DR
IV
E
NA
TU
RE
SHIPPING CONTAINER
No.2
2(B
ON
VIE
W C
IRC
UIT
)
No.1
8(B
ON
VIE
W C
IRC
UIT
)
ADJ. FACTORY UNDER CONSTRUCTION
ADJ. SLAB ONLY UNDER CONSTRICTION
EX
IST
ING
CR
OS
SIN
G
EX
IST
IN
G C
RO
SS
OV
ER
TO
BE
RE
MO
VE
D A
ND
IN
FILLE
D
TO
MA
TC
H N
AT
UR
E S
TR
IP A
ND
FO
OT
PA
TH
TO
TH
ES
AT
IS
FA
CT
ION
OF R
ES
PO
NS
IB
LE
AU
TH
OR
ITY
TO
BE
RE
LO
CA
TE
D
TO
BE
RE
LO
CA
TE
D
AD
JO
ININ
G A
LLO
TM
EN
T
18.09.19
18.09.19
25,550
2,4002,4002,6001502,6002,6002,6002,6002,6001,000
4,450
10,1
00
2,400.2,4002,6001502,6002,6002,6002,6002,6461,000
25,550
10,1
00
800
800
1,000
1,000
500
4,450
8,1
00
6,700 6,700 6,700
6,700 6,700 6,700
4,9
00
7,3
00
7,3
00
500
1,2
00
17,2
00
1,2
00
8,1
00
4,9
00
9,49
5
2,500
2,0
00
8,6
00
8,6
00
2,0
00
6,4
30.
6,4
30.
2,500
1,000
1,0
00
3,302
R 4,000
R 4,000
ALLOTMENT BOURNDARY 74.00m 184°41'00"
ALLOTMENT BOURNDARY 71.00m 4°41'00"
ALLO
TM
EN
T B
OU
RN
DA
RY
3
2.0
0m
2
74
°4
1'0
0"
ALLO
TM
EN
T B
OU
RN
DA
RY
3
2.0
0m
9
4°4
1'0
0"
ADJOINING ALLOTMENT
AD
JO
ININ
G A
LLO
TM
EN
T
ADJOINING ALLOTMENT
NOT FENCED
NO
T F
EN
CE
D
NO
T F
EN
CE
D
7.6 x 3.6 min
LOADING BAY
7.6 x 3.6 min
LOADING BAY
5800W
X 6
000H
RO
LLER D
OO
R
OFFICE
LOT 45
LOT 45
SETBACK
DP
DP
PR
OP
OS
ED
CR
OS
S O
VE
R
MB
123456
SE
TB
AC
K
123456CAR
PARK
SIGN
SE
TB
AC
K
SHARED AREA
SH
AR
ED
AR
EA
55.24 m2
EXTEN
T O
F U
PPER F
LO
OR
WAREHOUSE 2
FLOOR AREA 671.97m2
EXTEN
T O
F U
PPER
FLO
OR
TOTAL AREAinc. offic/mezz. storage: 838.67m2
F.F.L 10.40
F.F.L 10.40
PROTECTIVE KERB WITH MIN 150MM HPR
OT
EC
TIV
E K
ER
B W
IT
H M
IN
15
0M
M H
SETBACK
7
7
OFFICE55.24m2
WAREHOUSE 1FLOOR AREA 671.97m2
TOTAL AREAinc. offic/mezz. storage: 838.67m2
PROTECTIVE KERB WITH MIN 150MM H
PR
OT
EC
TIV
E K
ER
B W
IT
H M
IN
15
0M
M H
9
10
9
10
CANOPY OVER
CAN
OPY O
VER
CANOPY OVER
CAN
OPY O
VER
SELECTED
CONCRETE DRIVEWAY
PR
OP
OS
ED
2.1
m M
ET
AL
PIC
KE
T F
EN
CE
WIT
H G
AT
EP
RO
PO
SE
D 2
.1m
ME
TA
LP
ICK
ET
FE
NC
E W
ITH
GA
TE
MEZZANINE FLOOR ABOVE
MEZZANINE FLOOR ABOVE
5800W
X 6
000H
RO
LLER D
OO
R
MB
50
00
L C
AP
AC
IT
YR
WT
50
00
L C
AP
AC
IT
YR
WT
RAINGARDEN
LB G
DP DP
DP DPDP
DPDP
DP
Comm
unal space
Com
mun
al spa
ce
32.26m2
32.2
6m2
27.36m2
27.36m2
6.7m x 2.3m space
6.7m x 2.3m space
6.7m x 2.3m space
1.0M SIDE PEDESTRIAN FACILITY
EXTENT OF UPPER FLOOR
1.0M SIDE PEDESTRIAN FACILITY
6.7m x 2.3m space
6.7m x 2.3m space
SELECTEDCONCRETE DRIVEWAY
8
CAR P
ARK
SIGN
FENCING, LANDSCAPING AND SITESERVICES ARE TO BE NO GREATER THAN
1.0M IN HEIGHT WITHIN 2.5M OF THE FRONBOUNDARY
FENCING, LANDSCAPING AND SITE
SERVICES ARE TO BE NO GREATER THAN1.0M IN HEIGHT WITHIN 2.5M OF THE FRON
BOUNDARY
6.7m x 2.3m space
4.9m
x 2.6
m sp
ace
4.9
m x 2
.6m
space
4.9
m x 2
.6m
space
4.9
m x 2
.6m
space
4.9
m x 2
.6m
space
4.9m
x 2.6
m sp
ace
4.9
m x 2
.6m sp
ace
4.9m
x 2.6m
space
4.9m
x 2.6m
space
4.9
m x 2
.6m sp
ace
4.9
m x 2
.6m sp
ace
4.9
m x 2
.6m sp
ace
8
PRIVATE BIN COLLECTION
BIN STORAGE LOCATION
PRIVATE BIN COLLECTION
BIN STORAGE LOCATION
LB G
parkingemployees only
parkingemployees only
parkingemployees only
parkingemployees only
parkingemployees only
parkingemployees only
POLLARD
POLLARD
kitchen
SHR
OHC
920
920
EXEX
820
Ambulanttoilet
920
TIL
ED
1100 x
1100
MIN
dis.wc
1800H WALL
kitchen
SHR
OHC
920
920
EX
EX
820
Ambulanttoilet
920
TIL
ED
1100 x
1100
dis.wc
1800H WALL
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
selected balustrade to be min. 1000h
above FFL, as per BCA requirements
staircase to manufacturers
specifications andcomputations
UP
1 2 3 4 5 6 7 8 9 10 11 12 13 14
selected balustrade to be min. 1000h
above FFL, as per BCA requirements
staircase to manufacturers
specifications andcomputations
UP
handrail to be continuous for full flight of stairs
handrail to be continuous for full flight of stairs
TACTIL
ETACTIL
E
6.00m²
RAINGARDEN6.00m²
NEW EXTERNAL HYDRANTWITH DUAL HEAD
BOLLARDS MIN 1.0mAWAY FROM HYDRANTS
BOLLARDS MIN 1.0mAWAY FROM HYDRANTS
RAISED KERB
M : 0409 169 993
Proposed: amendmentsdate
concent of the author
in part or in whole with out the written
sheet no:Date:
M7 Design Group Pty. Ltd.
cJob No:
Client:
At:F - 03 9317 8119
T - 03 9317 8111
building designers
registered building practitionercopyright 2019: these drawings are not to be copied
03A : 9,61 Wattle RdMaidstone, Vic
WAREHOUSE DEVELOPMENT
LOT 45 APEX DRIVE TRUGANINA
1816 19.09.19
KARANFILOVSKI INVESTMENTS
30.09.19 AS PER SURVEYORS REQUEST
09.10.19 AS PER SURVEYORS REQUEST
150 45,150 150
150
31,7
00
150
150
2,1
90
90
2,3
30
90
2,3
00
90
8,6
85
150
8,6
85
90
2,3
00
90
2,3
30
90
2,1
90
150
150 5,250 90 2,300 90 37,420 150
150 1,550 3,700 90 2,300 90 37,420 150
45,450
32,0
00
150 1
,200
90
5,7
10
90
8,6
85
150
8,6
85
90
5,7
10
90
1,2
00150
150
7,0
00
90
8,6
85
150
8,6
85
90
7,0
00
150
15,9
25
150
15,9
25
32,0
00
150 45,150 150
150 5,250 90 2,300 90 37,420 150
150 1,550 3,700 90 2,300 90 37,420 150
45,450
4,3
00
1,0
00
150 7,400
150 7,4001,0
00
4,3
00
8,300.
8,300.
150
2,550
600
600
600
600
250 800 MAX
460-4
808
00
50 500
450-500 200-250 300
800
300
600
500
50
400
700
450
250
700
100
800
800
700
700
1,0
01
1,0
00
2,400
2,400
1,000 250
1,000 550
1,4001,950.
1,400
1,950.
1,1
00
90
1,100
1,100
90
1,1
00
sd
sd
sd
45.00°
ZONE FOR
POSITION OF
TOILET PAPER
DISPENSER.
ZONE FOR POSITION
OF FLUSH CONTROL
STAINLESS STEEL GRAB-RAIL. 30mm
MIN. -40mm MAX. DIA.
RAIL TO CONTINUE THOUGH WALL
LENGTH AS INDICATED
STAINLESS STEEL GRAB-RAIL. 30mm
MIN. -40mm MAX. DIA.
RAIL TO CONTINUE THOUGH WALL
LENGTH AS INDICATED
5800W
X 5
500H
RO
LLER D
OO
R
OFFICE
DP
DP
MB
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
selected balustrade to be min. 1000h
above FFL, as per BCA requirements
staircase to manufacturers
specifications andcomputations
EXTEN
T O
F U
PPER
FLO
OR
WAREHOUSE 2
FLOOR AREA 671.97m2
EXTEN
T O
F U
PPER F
LO
OR
TOTAL AREAinc. offic/mezz. storage: 838.67m2
F.F.L 10.40
F.F.L 10.40
kitchen
UP
SHR
OFFICE
1 2 3 4 5 6 7 8 9 10 11 12 13 14
selected balustrade to be min. 1000h
above FFL, as per BCA requirements
staircase to manufacturers
specifications andcomputations
UP
WAREHOUSE 1FLOOR AREA 671.97m2
TOTAL AREAinc. offic/mezz. storage: 838.67m2
CANOPY OVER
CAN
OPY O
VER
CAN
OPY O
VER
MEZZANINE FLOOR ABOVE
MEZZANINE FLOOR ABOVE
5800W
X 5
500H
RO
LLER D
OO
R
MB
50
00
L C
AP
AC
IT
YR
WT
50
00
L C
AP
AC
IT
YR
WT
DP DP
DP DPDP
DPDP
DP
EXTENT OF UPPER FLOOR
D0
1
Feature posts
OHC
920
920
920
920
920
920
920
920
D0
2D
03
D0
1D
02
D0
3
ALLOTMENT BOUNDARY
ALLOTMENT BOUNDARY
ALLO
TM
EN
T B
OU
ND
AR
YALLO
TM
EN
T B
OU
ND
AR
Y
handrail to be continuous for full flight of stairs
handrail to be continuous for full flight of stairs
GROUND FLOOR PLANSCALE 1:100
PA
N C
TR.
LIN
E
DISABLED TOILET LAYOUTDISABLED TOILET LAYOUT
EX
1200 x 300 Recessed T bar 2x36W
Fluorescent light fitting
Clevertronics emergency exit light
Clevertronics emergency light class
Clevertronics emergency light class
Kasten 2023 wall mounted external
Mistral 250mm exhaust fan to be ducted to
1 x 10 w CO D16/C90 B16class 9430
8170 1 x 40w CO D80/C90 C80
1 x 10w CO C25/C90 C25
light fitting from Eagle lighting
1x400w high bay light
Low voltage light
Light switch
10 Amp double gpo 1200 above floor
60 watt bayonet light fitting
Switch and meterboard
Direct wiring to HWS
external wall or roof
3Phase power for automatic roller shutter
EM
EM
ELECTRICAL LEGEND
FIRE:EMERGENCY LIGHTING EXIT SIGNSARE PORTABLE EXIT. DRY WATERFIRE BLANKETS FOR KITCHENS.
GENERAL NOTES:
EXTERNAL PARKING BAYS ARE TO HAVE A
GRADIENT OF NO GREATER THAN 1:40.
INTERNAL DOORS TO HAVE A MINIMUM
OPENING WIDTH OF 850mm FOR DISABLED
ACCESS.
PROVIDE DISABLED SIGNAGE THROUGHOUT
THE SITE IN ACCORDANCE WITH B.C.A SPEC 3.6
AND AS1428.1 -2009DENOTES FLAT LANDING AREA FOR
WHEELCHAIR ACCESS
MANEUVERING (1330mm WIDE
MINIMUM.)
DENOTES MAIN ENTRANCE DOORS
WITH A MINIMUM CLEAR OPENING
OF 850mm
DENOTES DISABLED PARKING
SPACES. THESE SPACES SHALL BE
CONSTRUCTED IN ACCORDANCE
WITH AS1428.1, AS1428.2 AND
AS2890.1. PROVIDE VERTICAL
SIGNAGE TO THESE SPACES IN
ACCORDANCE WITH AS2890.1 &
AS1428.1 (CLAUSE 13)
1
2
LEGENDNOTES
DISABLED ACCESS
GENERAL NOTES:
o All levels and dimensions must be checked and verified before commencing any work or workshop drawings.
o DO NOT SCALE DRAWING. Written dimensions take precedence over scale.
o All works are to be in accordance with BCA, SAA Codes, Building Regulations and any relevant council by-laws.
o This drawing to be read in conjunction with structural drawings & computations
ROOFING NOTES:
o All downpipes noted (DP) to be 150mm dia. PVC. Gutters 600mm(W) X 200mm (D )zincalume finish sheet steel, flashed and
capped over.
o Roof decking to be Trimdeck 0.48mm thick or approved similar zinalume finish sheet steel. Slope 3 degrees UNO. Sarking to
underside.
o Natural acrylic rooflighting to match steel deck profile. To be kept a minimum of 1000mm clear of gutters side boundaries
and ridge.
o Provide 3.0mm thick wire under roofing 300X150 grid.
AMENITIES NOTES:
o Use 90X45 F5 Seasoned pine framing @ 450mm ctrs.
o Ceiling & Floor joists as noted.
o All framing to comply with AS1684
o All airlock and W.C doors to have self closers (REMOVABLE HINGES)
o Apply Ceramic tiles to:
im pervious floors over approved sub-base.
300mm above vanity basins
1800mm high in showers
o Disabled toilets to comply with AS1428.1
FIRE FIGHTING NOTES:
o The layout of all equipment fixed to be such that actual lengths of travel to exit are no greater than 40.0m
o All escape doors to be fitted with latches openable from inside without the use of a key by a single handed action.
GLAZING NOTES:
o All glazing to comply with AS1288. Window manufacturer to provide a specification for the Building surveyor, prior to
installation.
o All windows to be Aluminium framed "Commercial" type sections, powder coated to selected colour. Window fabricaztor to
provide all angles and cover-plates in the same powder-coated colour.
OFFICE
FLOOR AREA (m2)
REQUIRED LIGHT AREA (m2)
TRANSLUCENT ROOFING (m
NATURAL LIGHT
2)
WINDOWS (m2)
TOTAL (m2)
CHECK OK OK
WAREHOUSE 1
TO BE PROVIDED AT A RATE 0F 10% OF AREA
OFFICE
FLOOR AREA (m2)
REQUIRED VENTILATION AREA (m2)
OPENABLE WINDOWS/DOOR (m 2)
ROLLER DOORS (m2)
TOTAL (m2)
CHECK OK
NATURAL VENTILATIONTO BE PROVIDED AT A RATE 0F 5% OF AREA
WAREHOUSE
WAREHOUSE 1
WAREHOUSE
0
42.31
444.7 42.31
0
33.59 8.02
34.8
160.52671.97
443.5 16.05
444.7
160.52671.97
8.16
OFFICE
FLOOR AREA (m2)
REQUIRED LIGHT AREA (m2)
TRANSLUCENT ROOFING (m
NATURAL LIGHT
2)
WINDOWS (m2)
ROLLER DOORS (m2)
TOTAL (m2)
CHECK
WAREHOUSE 2
TO BE PROVIDED AT A RATE 0F 10% OF AREA
OFFICE
FLOOR AREA (m2)
REQUIRED VENTILATION AREA (m2)
OPENABLE WINDOWS (m2)
ROLLER DOORS (m2)
TOTAL (m2)
CHECK
NATURAL VENTILATIONTO BE PROVIDED AT A RATE 0F 5% OF AREA
WAREHOUSE
WAREHOUSE 2
WAREHOUSE
AREA: ANALYSIS
OK
0 0
34.8 8.16
OK OK
0
42.31
444.7 42.31
160.52671.97
443.5 16.05
444.7
0
OK
0
33.59 8.02
34.8
160.52671.97
8.16
OK
0
34.8 8.16
TOTAL SITE AREA: 2272.00m²
WAREHOUSE 1FLOOR AREA: 671.97m2
OFFICE FLOOR AREA: 55.24m2
MEZZANINE AREA: 111.46m² TOTAL FLOOR AREA = 838.67m2
LAND AREA: 1136m²
WAREHOUSE 2FLOOR AREA: 671.97m²
OFFICE FLOOR AREA: 55.24m²MEZZANINE AREA: 111.46m² TOTAL FLOOR AREA = 838.67m2
LAND AREA: 1136m²
REQUIRED CAR SPACES PERCLAUSE 52.06
Warehouse 1 : 14 SPACES(783.95M2 net floor area)
Warehouse 2 : 14 SPACES(783.95M2 net floor area)Provided 20 spaces, PLUS 2 for each warehouse
TOTAL CAR SPACES PROVIDED = 22
Feature posts
SHARED AREA
SHARED AREA
7.6 x 3.6 min
LOADING BAY
7.6 x 3.6 min
LOADING BAY
Comm
unal space
Com
mun
al spa
ce
EX EM
EX
EM
Ambulant signage mounted on the wall(complied AS1428.1 - 2009)
stair to be adjusted to allow for handrail extension at the
bottom and allow 1m clear egress width
F.F
. L 1
0.2
5F.F
. L 1
0.2
5
EX
EX
EXEX
NOTE: ALL EXIT DOORS AND DOORS FORMINGPART OF A REQUIRED EXIT IS TO BE PROVIDED
WITH A SINGLE ACTION PULL DOWN LEVERHANDLE WHICH CAN ALWAYS BE OPEN - ABLEFROM THE SIDE SEEKING EGRESS TO CLAUSE
D2.21 OF THE BCA VOLUME 1
POLLARD
POLLARD
150mm THICK REINFORCED CONCRETETILT-UP WALL PANELS WITH 2HR FIRE
RATED JOINTS.
150mm THICK REINFORCED CONCRETETILT-UP WALL PANELS WITH 2HR FIRE
RATED JOINTS.
150mm THICK REINFORCED CONCRETETILT-UP WALL PANELS WITH 2HR FIRE
RATED JOINTS.
TACTIL
ETACTIL
E
(unisex sinage)
EX PROVIDE JUMBO TYPE EXIT SIGNS TO WAREHOUSE AREAS
NOTE:ALL EXIT DOORS AND DOORS FORMING PART OF A REQUIRED EXIT IS TO BEPROVIDED WITH A PULL DOWN LEVER HANDLE WHICH CAN ALWAYS BE OPEN-ABLE FROMTHE SIDE SEEKING EGRESS TO CLAUSE D2.21 OF THE BCA VOLUME 1
STAIRCASE TO MANUFACTURES SPECIFICATIONSAND TO BE IN ACCORDANCE WITH AS.1428.1
HANDRAIL TERMINATIONAS PER AS 1428.1-2009
STAIRCASE TO MANUFACTURES SPECIFICATIONSAND TO BE IN ACCORDANCE WITH AS.1428.1
HANDRAIL TERMINATION
AS PER AS 1428.1-2009
UP
UP
UP
UP
1:8 RAMP
THRESHOLD TOAS1428.1-2009
1:8 RAMP
THRESHOLD TOAS1428.1-2009
stair overall handrail is
550m from last tread
820
Ambulanttoilet
920
TIL
ED
1100 x
1100
MIN
dis.wc
1800H WALL
uni sex disable signagemounted on the wall
(complied AS1428.1 - 2009)
kitchen
SHR
OHC
920
920
Ambulant signage mounted on the wall(complied AS1428.1 - 2009)
EX
EX
(unisex sinage)
820
Ambulanttoilet
920
TIL
ED
1100 x
1100
MIN
dis.wc
1800H WALL
uni sex disable signagemounted on the wall
(complied AS1428.1 - 2009)
2A 20B (E) DRY CHEMICAL 2.0m
FROM ELECTRICAL BOARD
NEW 36mm HOSE REEL
CONNECTED TO 38mm
COPPER PIPE TO BE TO BE
RUN TO SHUT OFF VALVE
AT HOSE REEL
NEW EXTERNAL HYDRANT
WITH DUAL HEAD
9.0kg WATER BASED
EXTINGUISHER
80 B (E) DRY CHEMICAL
FIRE FIGHTING EQUIPMENT:
WALL WETTING SPRINKLER
HEAD WITH SHUT OFF VALVE
EXISTING EXTERNAL HYDRANT
WITH DUAL HEAD
EXISTING 36mm HOSE REEL
EXISTING EXTERNAL HYDRANT
WITH SINGEL HEAD
NOTE: ALL FIRE SERVICES TO BE COPPER TYPE B 16 GUAGE, MIN COVER 600mm
M : 0409 169 993
Proposed: amendmentsdate
concent of the author
in part or in whole with out the written
sheet no:Date:
M7 Design Group Pty. Ltd.
cJob No:
Client:
At:F - 03 9317 8119
T - 03 9317 8111
building designers
registered building practitionercopyright 2019: these drawings are not to be copied
04A : 9,61 Wattle RdMaidstone, Vic
WAREHOUSE DEVELOPMENT
LOT 45 APEX DRIVE TRUGANINA
1816 19.09.19
KARANFILOVSKI INVESTMENTS
30.09.19 AS PER SURVEYORS REQUEST
09.10.19 AS PER SURVEYORS REQUEST
7,700. 150 45,150 150
150 13,700. 90 1,550 90 37,420 150
150 14,850.90
40090
37,420 150
150 9,250. 3,500 1,10090
1,400 90 37,420 150
53,150
150
31,7
00
150
32,0
00
150
2,1
00
90
2,3
30
90
2,3
90
90
8,6
85
150
8,6
85
90
2,3
90
90
2,3
30
90
2,1
00
150
150
1,1
50
500
5,3
50
90
8,6
85
150
8,6
85
90
5,3
50
500
1,1
50
150
150
7,0
00
150
7,3
00
17,4
00
7,3
00
32,0
00
7,700. 150 45,150 150
150 13,700. 90 1,550 90 37,420 150
150 14,850.90
40090
37,420 150
150 9,250. 3,500 1,10090
1,400 90 37,420 150
53,150
150
7,0
00
150
3,350
3,350
700
6,4
50
600
600 7,000. 700
600
6,4
50
700
600 7,000. 700
250 800 MAX
460-4
808
00
50 500
450-500 200-250 300
800
300
600
500
50
400
700
450
250
700
100
1,1
50
1,1
50
950
950
sd
sd
45.00°
ZONE FOR
POSITION OF
TOILET PAPER
DISPENSER.
ZONE FOR POSITION
OF FLUSH CONTROL
STAINLESS STEEL GRAB-RAIL. 30mm
MIN. -40mm MAX. DIA.
RAIL TO CONTINUE THOUGH WALL
LENGTH AS INDICATED
STAINLESS STEEL GRAB-RAIL. 30mm
MIN. -40mm MAX. DIA.
RAIL TO CONTINUE THOUGH WALL
LENGTH AS INDICATED
DP
DP DP DP
DP DPDP
DP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
selected balustrade to be min. 1000h
above FFL, as per BCA requirements
staircase to manufacturers
specifications andcomputations
MEZZANINE
CAN
OPY O
VER
CANOPY OVER
CAN
OPY O
VER
CANOPY OVER
CAN
OPY O
VER
CAN
OPY O
VER
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16
17
18
selected balustrade to be min. 1000h
above FFL, as per BCA requirements
staircase to manufacturers
specifications andcomputations
DN
MEZZANINE
wc
kit
ch
en
sto
re
17
18DN
wc
kit
ch
en
sto
re
WAREHOUSE 2
FLOOR AREA 671.97m2
TOTAL AREAinc. offic/mezz. storage: 838.67m2
F.F.L 10.40
F.F.L 10.40
WAREHOUSE 1FLOOR AREA 671.97m2
TOTAL AREAinc. offic/mezz. storage: 838.67m2
F.F.L 14.20
F.F.L 14.20
50
00
L C
AP
AC
IT
YR
WT
50
00
L C
AP
AC
IT
YR
WT
DP
DP
storage use only
storage use only
OH
CO
HC
720
720
820
820
720
720
820
820
W0
1-B
W01-A
W0
1-A
W01-B
ALLOTMENT BOUNDARY
ALLOTMENT BOUNDARY
ALLO
TM
EN
T B
OU
ND
AR
YALLO
TM
EN
T B
OU
ND
AR
Y
selected balustrade to be min. 1000h
above FFL, as per BCA requirements
selected balustrade to be min. 1000h
above FFL, as per BCA requirements
FIRST FLOOR PLANSCALE 1:100
PA
N C
TR.
LIN
E
DISABLED TOILET LAYOUTDISABLED TOILET LAYOUT
EX
1200 x 300 Recessed T bar 2x36W
Fluorescent light fitting
Clevertronics emergency exit light
Clevertronics emergency light class
Clevertronics emergency light class
Kasten 2023 wall mounted external
Mistral 250mm exhaust fan to be ducted to
1 x 10 w CO D16/C90 B16class 9430
8170 1 x 40w CO D80/C90 C80
1 x 10w CO C25/C90 C25
light fitting from Eagle lighting
1x400w high bay light
Low voltage light
Light switch
10 Amp double gpo 1200 above floor
60 watt bayonet light fitting
Switch and meterboard
Direct wiring to HWS
external wall or roof
3Phase power for automatic roller shutter
EM
EM
ELECTRICAL LEGEND
FIRE:EMERGENCY LIGHTING EXIT SIGNSARE PORTABLE EXIT. DRY WATERFIRE BLANKETS FOR KITCHENS.
DENOTES FLAT LANDING AREA FOR
WHEELCHAIR ACCESS
MANEUVERING (1330mm WIDE
MINIMUM.)
DENOTES MAIN ENTRANCE DOORS
WITH A MINIMUM CLEAR OPENING
OF 850mm
DENOTES DISABLED PARKING
SPACES. THESE SPACES SHALL BE
CONSTRUCTED IN ACCORDANCE
WITH AS1428.1, AS1428.2 AND
AS2890.1. PROVIDE VERTICAL
SIGNAGE TO THESE SPACES IN
ACCORDANCE WITH AS2890.1 &
AS1428.1 (CLAUSE 13)
1
2
LEGENDNOTES
DISABLED ACCESS
GENERAL NOTES:
o All levels and dimensions must be checked and verified before commencing any work or workshop drawings.
o DO NOT SCALE DRAWING. Written dimensions take precedence over scale.
o All works are to be in accordance with BCA, SAA Codes, Building Regulations and any relevant council by-laws.
o This drawing to be read in conjunction with structural drawings & computations
ROOFING NOTES:
o All downpipes noted (DP) to be 150mm dia. PVC. Gutters 600mm(W) X 200mm (D )zincalume finish sheet steel, flashed and
capped over.
o Roof decking to be Trimdeck 0.48mm thick or approved similar zinalume finish sheet steel. Slope 3 degrees UNO. Sarking to
underside.
o Natural acrylic rooflighting to match steel deck profile. To be kept a minimum of 1000mm clear of gutters side boundaries
and ridge.
o Provide 3.0mm thick wire under roofing 300X150 grid.
AMENITIES NOTES:
o Use 90X45 F5 Seasoned pine framing @ 450mm ctrs.
o Ceiling & Floor joists as noted.
o All framing to comply with AS1684
o All airlock and W.C doors to have self closers (REMOVABLE HINGES)
o Apply Ceramic tiles to:
im pervious floors over approved sub-base.
300mm above vanity basins
1800mm high in showers
o Disabled toilets to comply with AS1428.1
FIRE FIGHTING NOTES:
o The layout of all equipment fixed to be such that actual lengths of travel to exit are no greater than 40.0m
o All escape doors to be fitted with latches openable from inside without the use of a key by a single handed action.
GLAZING NOTES:
o All glazing to comply with AS1288. Window manufacturer to provide a specification for the Building surveyor, prior to
installation.
o All windows to be Aluminium framed "Commercial" type sections, powder coated to selected colour. Window fabricaztor to
provide all angles and cover-plates in the same powder-coated colour.
OFFICE
FLOOR AREA (m2)
REQUIRED LIGHT AREA (m2)
TRANSLUCENT ROOFING (m
NATURAL LIGHT
2)
WINDOWS (m2)
TOTAL (m2)
CHECK OK OK
WAREHOUSE 1
TO BE PROVIDED AT A RATE 0F 10% OF AREA
OFFICE
FLOOR AREA (m2)
REQUIRED VENTILATION AREA (m2)
OPENABLE WINDOWS/DOOR (m 2)
ROLLER DOORS (m2)
TOTAL (m2)
CHECK OK
NATURAL VENTILATIONTO BE PROVIDED AT A RATE 0F 5% OF AREA
WAREHOUSE
WAREHOUSE 1
WAREHOUSE
0
42.31
444.7 42.31
0
33.59 8.02
34.8
160.52671.97
443.5 16.05
444.7
160.52671.97
8.16
OFFICE
FLOOR AREA (m2)
REQUIRED LIGHT AREA (m2)
TRANSLUCENT ROOFING (m
NATURAL LIGHT
2)
WINDOWS (m2)
ROLLER DOORS (m2)
TOTAL (m2)
CHECK
WAREHOUSE 2
TO BE PROVIDED AT A RATE 0F 10% OF AREA
OFFICE
FLOOR AREA (m2)
REQUIRED VENTILATION AREA (m2)
OPENABLE WINDOWS (m2)
ROLLER DOORS (m2)
TOTAL (m2)
CHECK
NATURAL VENTILATIONTO BE PROVIDED AT A RATE 0F 5% OF AREA
WAREHOUSE
WAREHOUSE 2
WAREHOUSE
AREA: ANALYSIS
OK
0 0
34.8 8.16
OK OK
0
42.31
444.7 42.31
160.52671.97
443.5 16.05
444.7
0
OK
0
33.59 8.02
34.8
160.52671.97
8.16
OK
0
34.8 8.16
TOTAL SITE AREA: 2272.00m²
WAREHOUSE 1FLOOR AREA: 671.97m2
OFFICE FLOOR AREA: 55.24m2
MEZZANINE AREA: 111.46m² TOTAL FLOOR AREA = 838.67m2
LAND AREA: 1136m²
WAREHOUSE 2FLOOR AREA: 671.97m²
OFFICE FLOOR AREA: 55.24m²MEZZANINE AREA: 111.46m² TOTAL FLOOR AREA = 838.67m2
LAND AREA: 1136m²
REQUIRED CAR SPACES PERCLAUSE 52.06
Warehouse 1 : 14 SPACES(783.95M2 net floor area)
Warehouse 2 : 14 SPACES(783.95M2 net floor area)Provided 20 spaces, PLUS 2 for each warehouse
TOTAL CAR SPACES PROVIDED = 22
EM
ventilation cowlsventilation cowls
EM EM
EM
ventilation cowlsventilation cowls
EM EM
EX
EX
150mm THICK REINFORCED CONCRETETILT-UP WALL PANELS WITH 2HR FIRE
RATED JOINTS.
150mm THICK REINFORCED CONCRETETILT-UP WALL PANELS WITH 2HR FIRE
RATED JOINTS.
150mm THICK REINFORCED CONCRETETILT-UP WALL PANELS WITH 2HR FIRE
RATED JOINTS.
GENERAL NOTES:
EXTERNAL PARKING BAYS ARE TO HAVE A
GRADIENT OF NO GREATER THAN 1:40.
INTERNAL DOORS TO HAVE A MINIMUM
OPENING WIDTH OF 850mm FOR DISABLED
ACCESS.
PROVIDE DISABLED SIGNAGE THROUGHOUT
THE SITE IN ACCORDANCE WITH B.C.A SPEC 3.6
AND AS1428.1 -2009
TACTILE
TACTILE
EX PROVIDE JUMBO TYPE EXIT SIGNS TO WAREHOUSE AREAS
NOTE:ALL EXIT DOORS AND DOORS FORMING PART OF A REQUIRED EXIT IS TO BEPROVIDED WITH A PULL DOWN LEVER HANDLE WHICH CAN ALWAYS BE OPEN-ABLE FROMTHE SIDE SEEKING EGRESS TO CLAUSE D2.21 OF THE BCA VOLUME 1
16
2A 20B (E) DRY CHEMICAL 2.0m
FROM ELECTRICAL BOARD
NEW 36mm HOSE REEL
CONNECTED TO 38mm
COPPER PIPE TO BE TO BE
RUN TO SHUT OFF VALVE
AT HOSE REEL
NEW EXTERNAL HYDRANT
WITH DUAL HEAD
9.0kg WATER BASED
EXTINGUISHER
80 B (E) DRY CHEMICAL
FIRE FIGHTING EQUIPMENT:
WALL WETTING SPRINKLER
HEAD WITH SHUT OFF VALVE
EXISTING EXTERNAL HYDRANT
WITH DUAL HEAD
EXISTING 36mm HOSE REEL
EXISTING EXTERNAL HYDRANT
WITH SINGEL HEAD
NOTE: ALL FIRE SERVICES TO BE COPPER TYPE B 16 GUAGE, MIN COVER 600mm
ef
ef
ef
ef
M : 0409 169 993
Proposed: amendmentsdate
concent of the author
in part or in whole with out the written
sheet no:Date:
M7 Design Group Pty. Ltd.
cJob No:
Client:
At:F - 03 9317 8119
T - 03 9317 8111
building designers
registered building practitionercopyright 2019: these drawings are not to be copied
05A : 9,61 Wattle RdMaidstone, Vic
WAREHOUSE DEVELOPMENT
LOT 45 APEX DRIVE TRUGANINA
1816 19.09.19
KARANFILOVSKI INVESTMENTS
30.09.19 AS PER SURVEYORS REQUEST
09.10.19 AS PER SURVEYORS REQUEST
3,350
3,350
600
600
600
600
600
30
0
450
600
30
0
400
150mm DIA
DOWN PIPE
STEEL PIPE BRACKETS AT
1500mm CTRS. MAX.
GRADE SUMP
TO OUTLET.
SPAN-DEK
BIRD-PROOFING
300W X 75D
BOX GUTTER
OVERFLOW
FLASHBACK
TO PANEL
CAPPING
CONCRETE
PANEL
STEEL PIPE BRACKETS AT
1500mm CTRS. MAX.
WRAP PIPE WITH
ABLEFLEX OR SIMILAR.
SCREWED I/O CAP.
150mm THICK REINFORCED
CONCRETE TILT-UP WALL PANELS.
BIRD-PROOFING
CONCRETE
PANEL
CB
CAPPING
FLASHBACK
TO PANEL
GRADE SUMP
TO OUTLET.
SPAN-DEK
STEEL PIPE BRACKETS AT
1500mm CTRS. MAX.
90 DEGREE
ELBOW
sump
sump
sump
sump
sump
CA
NO
PY
CA
NO
PY
CA
NO
PY
CA
NO
PY
sump
sump
1000mm WIDE TRANSLUCENT ROOFSHEETING. PROVIDE SAFETY MESH
UNDER. TYPECAL EACH BAY
8300mm WIDE TRANSLUCENT ROOF
SHEETING. PROVIDE SAFETY MESHUNDER. TYPECAL EACH BAY
8800mm WIDE TRANSLUCENT ROOF
SHEETING. PROVIDE SAFETY MESHUNDER. TYPECAL EACH BAY
sump
sumpsump
se
lecte
d 3
° g
alv
. ro
of
sh
ee
tin
g
se
lecte
d 3
° g
alv
. ro
of
sh
ee
tin
g
se
lecte
d 3
° g
alv
. ro
of
sh
ee
tin
g
se
lecte
d 3
° g
alv
. ro
of
sh
ee
tin
g1000mm WIDE TRANSLUCENT ROOFSHEETING. PROVIDE SAFETY MESH
UNDER. TYPECAL EACH BAY
8300mm WIDE TRANSLUCENT ROOFSHEETING. PROVIDE SAFETY MESH
UNDER. TYPECAL EACH BAY
8800mm WIDE TRANSLUCENT ROOFSHEETING. PROVIDE SAFETY MESH
UNDER. TYPECAL EACH BAY
se
lecte
d 3
° g
alv
. ro
of
sh
ee
tin
g
se
lecte
d 3
° g
alv
. ro
of
sh
ee
tin
g
se
lecte
d 3
° g
alv
. ro
of
sh
ee
tin
g
se
lecte
d 3
° g
alv
. ro
of
sh
ee
tin
g
ALLOTMENT BOUNDARY
ALLOTMENT BOUNDARY
ALLO
TM
EN
T B
OU
ND
AR
YALLO
TM
EN
T B
OU
ND
AR
Y
ROOF PLANSCALE 1:100
OFFICE
FLOOR AREA (m2)
REQUIRED LIGHT AREA (m2)
TRANSLUCENT ROOFING (m
NATURAL LIGHT
2)
WINDOWS (m2)
TOTAL (m2)
CHECK OK OK
WAREHOUSE 1
TO BE PROVIDED AT A RATE 0F 10% OF AREA
OFFICE
FLOOR AREA (m2)
REQUIRED VENTILATION AREA (m2)
OPENABLE WINDOWS/DOOR (m 2)
ROLLER DOORS (m2)
TOTAL (m2)
CHECK OK
NATURAL VENTILATIONTO BE PROVIDED AT A RATE 0F 5% OF AREA
WAREHOUSE
WAREHOUSE 1
WAREHOUSE
0
42.31
444.7 42.31
0
33.59 8.02
34.8
160.52671.97
443.5 16.05
444.7
160.52671.97
8.16
OFFICE
FLOOR AREA (m2)
REQUIRED LIGHT AREA (m2)
TRANSLUCENT ROOFING (m
NATURAL LIGHT
2)
WINDOWS (m2)
ROLLER DOORS (m2)
TOTAL (m2)
CHECK
WAREHOUSE 2
TO BE PROVIDED AT A RATE 0F 10% OF AREA
OFFICE
FLOOR AREA (m2)
REQUIRED VENTILATION AREA (m2)
OPENABLE WINDOWS (m2)
ROLLER DOORS (m2)
TOTAL (m2)
CHECK
NATURAL VENTILATIONTO BE PROVIDED AT A RATE 0F 5% OF AREA
WAREHOUSE
WAREHOUSE 2
WAREHOUSE
AREA: ANALYSIS
OK
0 0
34.8 8.16
OK OK
0
42.31
444.7 42.31
160.52671.97
443.5 16.05
444.7
0
OK
0
33.59 8.02
34.8
160.52671.97
8.16
OK
0
34.8 8.16
TOTAL SITE AREA: 2272.00m²
WAREHOUSE 1FLOOR AREA: 671.97m2
OFFICE FLOOR AREA: 55.24m2
MEZZANINE AREA: 111.46m² TOTAL FLOOR AREA = 838.67m2
LAND AREA: 1136m²
WAREHOUSE 2FLOOR AREA: 671.97m²
OFFICE FLOOR AREA: 55.24m²MEZZANINE AREA: 111.46m² TOTAL FLOOR AREA = 838.67m2
LAND AREA: 1136m²
REQUIRED CAR SPACES PERCLAUSE 52.06
Warehouse 1 : 14 SPACES(783.95M2 net floor area)
Warehouse 2 : 14 SPACES(783.95M2 net floor area)Provided 20 spaces, PLUS 2 for each warehouse
TOTAL CAR SPACES PROVIDED = 22
ROOFING AS NOTED
DOWN PIPE DETAIL
ROOFING AS NOTED
SUSPENDED PIPE DETAILBOX GUTTER DETAIL
Warehouse 1
The rainwater from warehouse 1 roof area of339.71m2 is to be collected and discharged via
a gravity fed system into a 5000L capacityrainwater tank which is to be connected to3no. toilets for toilet flushing. The roof area of
426.43m2 is to be collected and dischargedinto a 6m2 raingarden set back min. 300mm
from the dwelling. Area not to be treated is308.93m2.
Warehouse 2The rainwater from warehouse 2 roof area of
339.71m2 is to be collected and discharged viaa gravity fed system into a 5000L capacity
rainwater tank which is to be connected to3no. toilets for toilet flushing.The roof area of
426.43m2 is to be collected and dischargedinto a 6m2 raingarden set back min. 300mm
from the dwelling. Area not to be treated is308.93m2.
STORM RATING NOTES
M : 0409 169 993
Proposed: amendmentsdate
concent of the author
in part or in whole with out the written
sheet no:Date:
M7 Design Group Pty. Ltd.
cJob No:
Client:
At:F - 03 9317 8119
T - 03 9317 8111
building designers
registered building practitionercopyright 2019: these drawings are not to be copied
06A : 9,61 Wattle RdMaidstone, Vic
WAREHOUSE DEVELOPMENT
LOT 45 APEX DRIVE TRUGANINA
1816 19.09.19
KARANFILOVSKI INVESTMENTS
30.09.19 AS PER SURVEYORS REQUEST
09.10.19 AS PER SURVEYORS REQUEST
3,5
00
3,5
00
1,2
00
3,5
00
3,5
00
9,5
50
10,0
00
2,5
50
8650.
3,5
00
3,5
00
3,5
00
3,5
00
8,6
50
9,8
00
10,0
00
10,0
00
10,0
00
8,0
00
CL
CL
F.F.L 10.40
F.F.L 14.20
F.F.L 10.40
F.F.L 14.20
CL
CL
A
A
A
A
SOUTH ELEVATIONSCALE: 1:100
N.G.L
N.G.L
selected galvanised roof
sheeting @ 3º pitch
WAREHOUSE 2 WAREHOUSE 1
selected galvanised roof
sheeting @ 3º pitch
selected render finish
(concrete tilt panel)
wall
heig
ht
DARK GREY TONE
(A) Timeless Grey (dulux)- or similar(B) Domino (dulux) - or similar(C) Bright Delight (dulux) - or similar(D) Black Aluminium (matrix) - or similar
ITEM
MATERIALS SCHEDULE
COLOURS
CONCRETE DRIVEWAY
RAIN WATER TANK
CAPPING
ROLLER DOOR
WINDOWS / DOORS
WALLSEXTERNAL SURFACE
ALUMINIUM COLOURBOND
GREY TONE COLOURBOND
GALVONISED POUDERCOAT (BLACK TONE)
POUDERCOAT ALUMINIUM (BLACK TONE)
site cut
build
ing h
eig
ht
D
NORTH ELEVATIONSCALE: 1:100
C
C
C C C
C
C
C
C C
D
A A
B BB B
CL
CL
F.F.L 10.40
F.F.L 14.20
F.F.L 10.40
F.F.L 14.20
CL
CL
selected aluminium windows
selected galvanised roof
sheeting @ 3º pitchselected matrix panel finish
selected aluminium windows
selected galvanised roof
sheeting @ 3º pitch
selected render finish
selected roller door
6000h x 6000w
provide step as indicated,to be confirmed on site
selected render finish
selected roller door
6000h x 6000w
provide step as indicated,to be confirmed on site
selected aluminium strips
WAREHOUSE 1 WAREHOUSE 2
N.G.LN.G.L
A
appro
x w
all
heig
ht
site cut
A A
A
build
ing h
eig
ht
PROPOSED SIGN PROPOSED SIGN
build
ing h
eig
ht
matrix cladding matrix cladding
selected render finish(concrete tilt panel)
AJOINING FACTORY HEIGHTNo.2/19ADJ. SLAB ONLY UNDER
CONSTRICTION
18.09.19
ADJ. FACTORY UNDER
CONSTRUCTION18.09.19
AJOINING FACTORY HEIGHT
M : 0409 169 993
Proposed: amendmentsdate
concent of the author
in part or in whole with out the written
sheet no:Date:
M7 Design Group Pty. Ltd.
cJob No:
Client:
At:F - 03 9317 8119
T - 03 9317 8111
building designers
registered building practitionercopyright 2019: these drawings are not to be copied
07A : 9,61 Wattle RdMaidstone, Vic
WAREHOUSE DEVELOPMENT
LOT 45 APEX DRIVE TRUGANINA
1816 19.09.19
KARANFILOVSKI INVESTMENTS
30.09.19 AS PER SURVEYORS REQUEST
09.10.19 AS PER SURVEYORS REQUEST
8650.
1,3
50.
3,5
00
3,5
00
3,5
00
7,3
00
10,0
00
10,0
00
9,8
00.
9,5
50
3,5
00
3,5
00
7,3
00
2,5
50
1,0
0010,0
00
3,5
00
3,5
00
1,0
00
7,3
00
2,5
50
10,0
00
10,0
00
8650.
1,3
50.
8650.
8650.
1,3
50.
8650.
8650.
8650.
3,5
00
DARK GREY TONE
(A) Timeless Grey (dulux)- or similar(B) Domino (dulux) - or similar(C) Bright Delight (dulux) - or similar(D) Black Aluminium (matrix) - or similar
ITEM
MATERIALS SCHEDULE
COLOURS
CONCRETE DRIVEWAY
RAIN WATER TANK
CAPPING
ROLLER DOOR
WINDOWS / DOORS
WALLSEXTERNAL SURFACE
ALUMINIUM COLOURBOND
GREY TONE COLOURBOND
GALVONISED POUDERCOAT (BLACK TONE)
POUDERCOAT ALUMINIUM (BLACK TONE)
A
A
A
A
A
A
A
A
A
A
CL
CL
F.F.L 10.40
F.F.L 14.20
F.F.L 10.40
selected galvanised roofsheeting @ 3º pitch
appro
x w
all
heig
ht
WAREHOUSE 1
N.G.LN.G.L
A
A
A
A
A
A
A
A
A
A
CL
F.F.L 10.40F.F.L 10.40
F.F.L 14.20
CL
CL
selected galvanised roof
sheeting @ 3º pitch
appro
x w
all
heig
ht
WEST ELEVATIONSCALE: 1:100
WAREHOUSE 2N.G.L
selected render finish
appro
x w
all
heig
ht
appro
x w
all
heig
ht
site cut
C
C
CC
A A
BB
A
F.F.L 10.40F.F.L 10.40
F.F.L 14.20
CL
CL
OFFICE
MEZZANINE
selected aluminium windows
selected galvanised roofsheeting @ 3º pitch
selected galvanised roofsheeting @ 3º pitch
selected aluminium strips
CL
appro
x f
act
ory
heig
ht
INTERNAL - WEST ELEVATIONSCALE: 1:100
WAREHOUSE 1
selected handrail at 1000mm above FFL
N.G.L N.G.L
C
C
C C
AA
B B
A
F.F.L 10.40 F.F.L 10.40
F.F.L 14.20
CL
CL
OFFICE
MEZZANINE
selected aluminium windows
selected galvanised roofsheeting @ 3º pitch
selected galvanised roofsheeting @ 3º pitch
selected aluminium strips
CL
appro
x f
act
ory
heig
ht
INTERNAL - EAST ELEVATIONSCALE: 1:100
WAREHOUSE 2
selected handrail at 1000mm above FFL
N.G.LN.G.L
appro
x w
all
heig
ht
CL
CL
EAST ELEVATIONSCALE: 1:100
selected render finish(concrete tilt panel)
selected render finish(concrete tilt panel)
selected render finish(concrete tilt panel)
selected render finish(concrete tilt panel)
M : 0409 169 993
Proposed: amendmentsdate
concent of the author
in part or in whole with out the written
sheet no:Date:
M7 Design Group Pty. Ltd.
cJob No:
Client:
At:F - 03 9317 8119
T - 03 9317 8111
building designers
registered building practitionercopyright 2019: these drawings are not to be copied
08A : 9,61 Wattle RdMaidstone, Vic
WAREHOUSE DEVELOPMENT
LOT 45 APEX DRIVE TRUGANINA
1816 19.09.19
KARANFILOVSKI INVESTMENTS
30.09.19 AS PER SURVEYORS REQUEST
09.10.19 AS PER SURVEYORS REQUEST
3,5
00
3,5
00
2,7
00
3,5
00
3,5
00
2,7
00
1,80090
920 92090
1,800
3,5
00
5,5
00
5,800
6,400 4,300
3,1
00
3,5
00
1,80090
920 92090
1,800
3,5
00
5,5
00
5,800
6,400 4,300
3,1
00
3,5
00
920
2,7
00
920
2,7
00
100100
50
1,1
00
1,5
00
8650
150mm THICK REINFORCEDCONCRETE TILT-UP WALL PANELS
WITH 2HR FIRE RATED JOINTS.
150mm THICK REINFORCEDCONCRETE TILT-UP WALL PANELS
WITH 2HR FIRE RATED JOINTS.
CL
CL
F.F.L 10.40
F.F.L 14.20
F.F.L 10.40
F.F.L 14.20
CL
CL
N.G.LN.G.L
WAREHOUSE 1WAREHOUSE 2
SECTION A-ASCALE 1:100
kitchendis.wc SHR W.C
WAREHOUSE 2
FLOOR AREA
MEZZANINEwc kitchen
kitchen dis.wcSHRW.C
WAREHOUSE 1
FLOOR AREA
MEZZANINE wckitchen
selected balustrade to be min. 1000habove FFL, as per BCA requirements
staircase to manufactures specifications
NOTE:
refer to engineers specificationsand computations for all footing detail'slintel and beam design
selected balustrade to be min. 1000h
above FFL, as per BCA requirements
staircase to manufactures specificationsland adjacent to perimeter footingsis to be graded away @ 1:50 over 1m
F F
F F F F F F F F
D01ENTRY DOOR
CONBINATION WITH WINDOWROLLER DOOR
D02SIDE DOOR
D03
W01ACORNER WINDOW
W01B
F F
F F F F F F F F
D01ENTRY DOOR
CONBINATION WITH WINDOWROLLER DOOR
D02SIDE DOOR
D03
W01ACORNER WINDOW
W01B
NOTE:WINDOWS SIZES AND STYLES ARE NOMINAL ONLY & AREMEASURED INTERNALLYBETWEEN REVEALS. ACTUAL WINDOW SIZES MAY VARYDEPENDING ON THEMANUFACTURERS STANDARDS. THE OWNER IS TO CONFIRM THESIZES WITH THEBUILDER'S WINDOW MANUFACTURER PRIOR TO COMMENCEMENT.WINDOWS TO BEFLASHED AS REQUIRED ALL WINDOWS ARE TO BE INACCORDANCE WITH A.S. 1288
WINDOW LEGEND
NOTE:
WINDOWS SIZES AND STYLES ARE NOMINAL ONLY & ARE MEASURED INTERNALLYBETWEEN REVEALS. ACTUAL WINDOW SIZES MAY VARY DEPENDING ON THE
MANUFACTURERS STANDARDS. THE OWNER IS TO CONFIRM THE SIZES WITH THE
BUILDER'S WINDOW MANUFACTURER PRIOR TO COMMENCEMENT. WINDOWS TO BE
FLASHED AS REQUIRED ALL WINDOWS ARE TO BE IN ACCORDANCE WITH A.S. 1288
F. DENOTES - Fixed Glazing
O. DENOTES - Openable GlazingSL. DENOTES - Sliding Door
OBS DENOTES - Obscured GlazingSG DENOTES - Safety Glass as per AS1288
CP DENOTES - All glazing to be pilkington comfort plus or similar
SUSEPENDED CEILING
SUSEPENDED CEILING
selected roof sheeting@ 3º pitch
refer to engineer's design andcomputations for first floor framing details
refer to engineer's design andcomputations for first floor framing details
WAREHOUSE 1 - FIRST FLOOR (WINDOW SCHEDULE)
WAREHOUSE 1 - GROUND FLOOR (DOOR SCHEDULE)
All window sizes to be confirmed by
manufacturer + Builder prior to and on site
All door sizes to be confirmed on site
Custom Measurement, all window
sizes to be confirmed on site
Custom Measurement, all window
sizes to be confirmed on site
WAREHOUSE 2 - FIRST FLOOR (WINDOW SCHEDULE)
WAREHOUSE 2 - GROUND FLOOR (DOOR SCHEDULE)
Custom Measurement, all window
sizes to be confirmed on site
Custom Measurement, all window
sizes to be confirmed on site
All window sizes to be confirmed by
manufacturer + Builder prior to and on site
All door sizes to be confirmed on site
12
00 M
AX
REFER
NO
TES B
ELO
W
20
00 M
IN.
NFL
100 MIN.FFL
MOUNT ON BRACKET
WITH A SECURE FIXING
TO MOUNTING POINT
SIGN TO BE LOCATED TO BE VISIBLE FROM 15m & ALL DIRECTIONS OF APPROACH.
PROVIDE ADDITIONAL SIGN OR SIGNS PERPENDICLAR TO THE WALL WHERE
LOCATION SIGN
EXTINGUISHER INSTALLATION DETAIL
LOCATE & MOUNT IN ACCORDANCE WITH AS 2444 CL. 3.3.3
FIXING POINT HEIGHT
INSTALLED IN CORRIDORS.
PREFERRED EXT. MOUNTING HEIGHT 2A 80B(E) = 900 AFFL
PREFERRED EXT. MOUNTING HEIGHT 20 & 40B(E) = 1200 AFFL
F.S.L
3. HOSE LENGTH 36m x 19mm Ø. FIT 6mm NOZZLE2. INSTALL HOSE REEL IN ACCORDANCE WITH AS 2441-1988
1. MANUFACTURE HOSE REEL IN ACCORDANCE WITH AS 1221-1991
INTERNAL HOSE REEL INSTALLATIONNOTE: 100mm min CLEARANCE REQUIRED ALL AROUND DRUM & VALVE
NOTE: REELS INSTALLED IN CUPBOARDS SHALL BE INSTALLED AS CLOSE
PRACTICAL TO THE BACK OF THE DOOR AND NOT MORE THAN 50mm FROM
THE BACK OF THE DOOR PROVIDE 50mm SIGN 'FIRE HOSE REEL'.
CONTROL VALVE
100mm min
CLEARANCE ALL
AROUND
CONNECT TO
FIRE MAIN
32mm COPPER
HOSE DRUM
100mm MIN CLEARANCE
ALL AROUND
HOSE DRUM GENERAL NOTES:
EXTERNAL PARKING BAYS ARE TO HAVE A
GRADIENT OF NO GREATER THAN 1:40.
INTERNAL DOORS TO HAVE A MINIMUM
OPENING WIDTH OF 850mm FOR DISABLED
ACCESS.
PROVIDE DISABLED SIGNAGE THROUGHOUT
THE SITE IN ACCORDANCE WITH B.C.A SPEC 3.6
AND AS1428.1DENOTES FLAT LANDING AREA FOR
WHEELCHAIR ACCESS
MANEUVERING (1330mm WIDE
MINIMUM.)
DENOTES MAIN ENTRANCE DOORS
WITH A MINIMUM CLEAR OPENING
OF 850mm
DENOTES DISABLED PARKING
SPACES. THESE SPACES SHALL BE
CONSTRUCTED IN ACCORDANCE
WITH AS1428.1, AS1428.2 AND
AS2890.1. PROVIDE VERTICAL
SIGNAGE TO THESE SPACES IN
ACCORDANCE WITH AS2890.1 &
AS1428.1 (CLAUSE 13)
1
2
LEGENDNOTES
DISABLED ACCESS
GENERAL NOTES:
o All levels and dimensions must be checked and verified before commencing any work or workshop drawings.
o DO NOT SCALE DRAWING. Written dimensions take precedence over scale.
o All works are to be in accordance with BCA, SAA Codes, Building Regulations and any relevant council by-laws.
o This drawing to be read in conjunction with structural drawings & computations
ROOFING NOTES:
o All downpipes noted (DP) to be 150mm dia. PVC. Gutters 600mm(W) X 200mm (D )zincalume finish sheet steel, flashed and
capped over.
o Roof decking to be Trimdeck 0.48mm thick or approved similar zinalume finish sheet steel. Slope 3 degrees UNO. Sarking to
underside.
o Natural acrylic rooflighting to match steel deck profile. To be kept a minimum of 1000mm clear of gutters side boundaries
and ridge.
o Provide 3.0mm thick wire under roofing 300X150 grid.
AMENITIES NOTES:
o Use 90X45 F5 Seasoned pine framing @ 450mm ctrs.
o Ceiling & Floor joists as noted.
o All framing to comply with AS1684
o All airlock and W.C doors to have self closers (REMOVABLE HINGES)
o Apply Ceramic tiles to:
im pervious floors over approved sub-base.
300mm above vanity basins
1800mm high in showers
o Disabled toilets to comply with AS1428.1
FIRE FIGHTING NOTES:
o The layout of all equipment fixed to be such that actual lengths of travel to exit are no greater than 40.0m
o All escape doors to be fitted with latches openable from inside without the use of a key by a single handed action.
GLAZING NOTES:
o All glazing to comply with AS1288. Window manufacturer to provide a specification for the Building surveyor, prior to
installation.
o All windows to be Aluminium framed "Commercial" type sections, powder coated to selected colour. Window fabricaztor to
provide all angles and cover-plates in the same powder-coated colour.
in a stairway, a min 2m height must be achieved
measured vertically above the nosing line at any pointand stairs to not exceed 18 risers
SUSEPENDED CEILING
M : 0409 169 993
Proposed: amendmentsdate
concent of the author
in part or in whole with out the written
sheet no:Date:
M7 Design Group Pty. Ltd.
cJob No:
Client:
At:F - 03 9317 8119
T - 03 9317 8111
building designers
registered building practitionercopyright 2019: these drawings are not to be copied
09A : 9,61 Wattle RdMaidstone, Vic
WAREHOUSE DEVELOPMENT
LOT 45 APEX DRIVE TRUGANINA
1816 19.09.19
KARANFILOVSKI INVESTMENTS
30.09.19 AS PER SURVEYORS REQUEST
09.10.19 AS PER SURVEYORS REQUEST
AMBULANT W.C DETAILSNOT TO SCALE
AS PER AS 1428 - 2009
DISABLE W.C DETAILSNOT TO SCALE
DISABLE W.C DETAILSNOT TO SCALE
WATER PROOFING DETAILS, TYP. WATER PROOFING DETAILS, TYP.
M : 0409 169 993
Proposed: amendmentsdate
concent of the author
in part or in whole with out the written
sheet no:Date:
M7 Design Group Pty. Ltd.
cJob No:
Client:
At:F - 03 9317 8119
T - 03 9317 8111
building designers
registered building practitionercopyright 2019: these drawings are not to be copied
10A : 9,61 Wattle RdMaidstone, Vic
WAREHOUSE DEVELOPMENT
LOT 45 APEX DRIVE TRUGANINA
1816 19.09.19
KARANFILOVSKI INVESTMENTS
30.09.19 AS PER SURVEYORS REQUEST
09.10.19 AS PER SURVEYORS REQUEST
STAIRS AS PER AS 1428.1-2009
M : 0409 169 993
Proposed: amendmentsdate
concent of the author
in part or in whole with out the written
sheet no:Date:
M7 Design Group Pty. Ltd.
cJob No:
Client:
At:F - 03 9317 8119
T - 03 9317 8111
building designers
registered building practitionercopyright 2019: these drawings are not to be copied
11A : 9,61 Wattle RdMaidstone, Vic
WAREHOUSE DEVELOPMENT
LOT 45 APEX DRIVE TRUGANINA
1816 19.09.19
KARANFILOVSKI INVESTMENTS
30.09.19 AS PER SURVEYORS REQUEST
09.10.19 AS PER SURVEYORS REQUEST