ADD2 - 1 Project No. FH186084 ADDENDUM TO SPECIFICATIONS ENTITLED “SPECIFICATIONS FOR WARDLAW COLLEGE ROOF REPLACEMENT STATE PROJECT NO. 50003317-2 WARDLAW COLLEGE COLLEGE OF EDUCATION 820 SOUTH MAIN STREET COLUMBIA, SOUTH CAROLINA” ADDENDUM NO. 2 JULY 24, 2019 The Specifications and Drawings contained in the project manual entitled “Specifications for Wardlaw College Roof Replacement, State Project No. 50003317-2, Wardlaw College, College of Education, 820 South Main Street, Columbia, South Carolina” are amended as follows: GENERAL 1. Results were returned as Negative for Asbestos at the exterior stucco wall along Roof Area F. Asbestos test results are attached. DRAWINGS 1. Delete Drawings G-101, A-101 and A-103 in their entirety and replace with attached Drawings G-101, A-101, A-103 (Addendum No. 2) Nothing herein is to be interpreted or construed as changing any provisions of the specifications except as specifically stated herein. Enclosure: Asbestos Test Results G-101, A-101 and A-103 (Addendum No. 2) END OF ADDENDUM

GENERAL DRAWINGS END OF ADDENDUM - Purchasing

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GENERAL DRAWINGS END OF ADDENDUM - Purchasing

ADD2 - 1

Project No. FH186084

ADDENDUM TOSPECIFICATIONS ENTITLED

“SPECIFICATIONS FORWARDLAW COLLEGE ROOF REPLACEMENT

STATE PROJECT NO. 50003317-2WARDLAW COLLEGE

COLLEGE OF EDUCATION820 SOUTH MAIN STREET

COLUMBIA, SOUTH CAROLINA””

ADDENDUM NO. 2 JULY 24, 2019

The Specifications and Drawings contained in the project manual entitled “Specifications forWardlaw College Roof Replacement, State Project No. 50003317-2, Wardlaw College, Collegeof Education, 820 South Main Street, Columbia, South Carolina” are amended as follows:

GENERAL

1. Results were returned as Negative for Asbestos at the exterior stucco wall along RoofArea F. Asbestos test results are attached.

DRAWINGS

1. Delete Drawings G-101, A-101 and A-103 in their entirety and replace with attachedDrawings G-101, A-101, A-103 (Addendum No. 2)

Nothing herein is to be interpreted or construed as changing any provisions of the specificationsexcept as specifically stated herein.

Enclosure: Asbestos Test ResultsG-101, A-101 and A-103 (Addendum No. 2)

END OF ADDENDUM

Page 2: GENERAL DRAWINGS END OF ADDENDUM - Purchasing

Page 1 of 3

SiteBuildingFloor Room: Equipment

COLUMBIA080ROOF

Request # Description FM00568662 HAZMAT SURVEY - 080

CP Number 50003317-2 WARDLAW COLLEGE ROOF REPLACEMENT

Project Manager Telephone

BRANHAM, DALE777-1288

Task List

23-JUL-19 HAZMAT SURVEY RESULTSSURVEY DATE: 7/23/2019

INSPECTOR #: ANTONIO THOMPSON (GR00052)

SCOPE: THE FOLLOWING SURVEY WAS PERFORMED IN PREPARATIONS TO REPAIR DAMAGE STUCCO ON THE EXTERIOR PORTION OF THE BUILDING.

ASBESTOS SECTION: STUCCO: NEGATIVE FOR ASBESTOS

INSPECTOR NOTES:1. IF A BUILDING MATERIAL IS NOT LISTED, DO NOT ASSUME THAT IT DOES NOT CONTAIN ASBESTOS. IT MAY NOT HAVE BEEN TESTED. FOR FURTHER INFORMATION, PLEASE CONTACT THE USC HAZMAT PROGRAM.

2. IF YOU ENCOUNTER ANY OTHER MATERIALS IN PLACE AND DEEM THEM SUSPECT FOR ASBESTOS AND/OR LEAD, PLEASE STOP WORK AND CONTACT THE ASBESTOS PROGRAM MANAGER FOR FURTHER TESTING OR ABATEMENT.

3. PLEASE NOTE THAT THE MATERIAL QUANTITY PROVIDED ON THE FIELD SHEET IS ONLY AN ESTIMATE FOR SAMPLING PURPOSES. THE QUANTITY

Note Date Title

WARDLAW COLLEGE

FM00568662Description HAZMAT SURVEY - 080

FIXED PRICE

Estimated Cost

Requestor Telephone Alternate Telephone

USC Work Order

Non-Available Time

Parent WO #

$ 2,958.50

CL013-57140 (FACILITIES PLANNING - CONSTR)Billing

Supervisor's Approval

EQUIPMENT

DATE WORK STARTED CAUSE

DATE WORK COMPLETED CONDITION

CLOSING REMARKS

BENCHSTOCK MATERIALSQty Description Price Per Unit

Assigned ToCrewStart DateDue dateRequest Date by

SSINCLAIRHAZMAT16-APR-18

22-FEB-18 CAMOORE

Priority 20

State/Internal Project Number H27-Z377

*FM00568662*

Page 3: GENERAL DRAWINGS END OF ADDENDUM - Purchasing

Page 2 of 3

02-MAY-18

30-JUN-18

HAZMAT SURVEY RESULTS

HAZMAT SURVEY RESULTS

SHOULD BE FIELD VERIFIED FOR ALL OTHER PURPOSES INCLUDING ABATEMENT. THIS SURVEY IS ONLY VALID FOR THE DESIGNATED AREA(S)/LOCATION(S) TESTED IE: (WARDLAW COLLEGE EXTERIOR WALLS).

SURVEY DATE:05/07/2018

INSPECTOR #: SIMONE WARREN (GR00052)

SCOPE: THE FOLLOWING SURVEY WAS PERFOMRED IN PREPARATION TO REMOVE/REPLACE EXISTING ROOF AT WARDLAW COLLEGE. THE FOLLOWING SECTIONS TO BE IMPACTED INCLUDE: SECTIONS A, B, C, D, E, AND F.PLEASE SEE ATTACHMENT FOR IMAGES, BIRDS EYE VIEW OF ROOF, AND SECTION DESIGNATIONS. PLEASE NOTE: IN-HOUSE ROOFERS CORE DRILLED ROOFING MATERIAL TO THE DECK. LAB RESULTS WILL REFLECT RESULTS FOR ALL LAYERS. CLIENT INDICATED THAT HVAC DUCT WORK AND HVAC DUCT MASTICS & ITS CORRESPONDING CAULK WILL NOT BE IMPACTED BY PLANNED WORK ACTIVITIES. CLIENT HAS ALSO INDICATED THAT ROOF LAYERS SHALL BE TREATED AS ONE UNIT AND OTHERWISE CANNOT BE ABATED SEPERATELY BY LAYER.

ASBESTOS SECTION :SECTIONS A,B,C,D, E AND F • ROOFING MATERIAL: POSITIVE FOR ASBESTOS• ALL EXISTING ROOF FELT:TREATED POSITIVE FOR ASBESTOS• ROOF FLASHING (TO INCLUDE ALL PATCHWORK): POSITIVE FOR ASBESTOS.• WHITE SEALANT AND ANY OTHER MATERIAL USED TO PATCH AND SEAL AREAS ON ROOF :TREATED POSITIVE FOR ASBESTOS • ALL EXISTING CAULK ENCOUNTERED: POSITIVE FOR ASBESTOS (PLEASE SEE LINE 1 INSPECTORS NOTES FOR EXCLUSIONS TO THIS LINE ITEM) • SILVER PAINTED DECORATIVE ORNAMENTS/ROOF FELT/CAULK: POSITIVE FOR ASBESTOS. PLEASE NOTE: ROOF FELT MATERIAL WAS PRESENT UNDER SILVER PAINT. RESULTS FOR ROOF FELT: 60% CHRYSOTILE. CORRESPONDING SILVER CAULK IS ALSO POSITIVE FOR ASBESTOS.• TEXTURED PLASTER (SECTION F: INTERIOR STAIRWELL): NEGATIVE FOR ASBESTOS•HVAC DUCT WORK (BLACK INTERIOR/WHITE EXTERIOR) : NEGATIVE FOR ASBESTOS

LEAD SECTION:SILVER PAINT OBSERVED ON DECORATIVE ORNAMENTS: POSITIVE FOR LEADYELLOW PAINTED WALL AT METAL COPING: POSITIVE FOR LEAD WHITE & RED PAINT ON BIRD HOUSE (METAL AND CONCRETE SUBSTRATE): POSITIVE FOR LEAD VENT PIPES: POSITIVE FOR LEADGREEN/BLACK PAINTED CAULK (SECTION C-ACCESS PANEL BOX): NEGATIVE FOR LEADELEVATOR MACHINE RM EXTERIOR WALLS: NEGATIVE FOR LEAD BEIGE PAINTED STAIR WELL (SECTION F):NEGATIVE FOR LEAD BEIGE PAINTED CEILINGS – (SECTION F- STAIRWELL): NEGATIVE FOR LEAD WHITE PAINTED HVAC BRACKET (SECTION A): NEGATIVE FOR LEAD

INSPECTORS NOTES: (PLEASE SEE ATTACHED IMAGES) DURING OBSERVATION, THERE WERE LOCATIONS WHERE EXISTING CAULK APPEARED TO BE CROSS CONTAMINATED WITH EXCESS ROOF FLASHING MATERIAL (WHICH TESTED POSITIVE FOR ASBESTOS). FOR THESE REASONS- ANY GRAY, WHITE, BEIGE, CLEAR, AND BROWN CAULK FOUND ON THE ROOF, ON PERIMETER OF DOORS, PERIMETER OF ELEVATOR MACHINE ROOM/STAIR WELL (EXTERIOR), AND/OR ON THE PERIMETER OF METAL FLASHING SHALL BE TREATED AS POSITIVE FOR ASBESTOS. SEE LIST BELOW FOR EXCLUSIONS: 1. (CAULK EXCLUSIONS)-***CAULK THAT WILL BE VIEWED AS NEGATIVE FOR ASBESTOS***: •BROWN CAULK ON PERIMETER OF EXTERIOR WINDOWS: NEGATIVE FOR ASEBSTOS

2. THERE ARE VARIOUS ITEMS ON THE ROOF, NOT LIMITED TO :SUPPORT ANCHORS FOR HVAC UNIT, EXHAUST FANS, PITCH POCKETS, VENT PIPES, HVAC UNIT BRACKETS, AND ANY OTHERS THAT HAVE CONTAMINATED ROOFING MATERIAL ON ITS SURFACE. IF THERE ANY PLANS MADE TO DISPOSE ANY OF THE PRESENT ITEMS, CONSIDERATIONS SHALL BE MADE TO DISPOSE OF ANY RESIDUAL ROOFING MATERIAL LEFT ON THESE SURFACES AS ACM.

3. THERE APPEARED TO BE A RUBBER SHEET BELOW ROOF COPINGS THAT LOOKED TO BE MECHANICALLY FASTENENED IN PLACE. THE RUBBER SHEET IS NON SUSPECT FOR ASBESTOS. IF ANY ADDITONAL MATERIAL IS ENCOUNTERED DURING REMOVAL OF ROOF COPING, AND ANYWHERE ELSE ON ROOF, PLEASE STOP WORK AND CONTACT USC HAZMAT TO REASSESS.

4. IF A BUILDING MATERIAL IS NOT LISTED, DO NOT ASSUME THAT IT DOES NOT CONTAIN ASBESTOS. IT MAY NOT HAVE BEEN TESTED. FOR FURTHER INFORMATION, PLEASE CONTACT THE USC HAZMAT PROGRAM.

5. IF YOU ENCOUNTER ANY OTHER MATERIALS IN PLACE AND DEEM THEM SUSPECT FOR ASBESTOS AND/OR LEAD, PLEASE STOP WORK AND CONTACT THE ASBESTOS PROGRAM MANAGER FOR FURTHER TESTING OR ABATEMENT.

6. PLEASE NOTE THAT THE MATERIAL QUANTITY PROVIDED ON THE FIELD SHEET IS ONLY AN ESTIMATE FOR SAMPLING PURPOSES. THE QUANTITY

FM00568662 USC Work Order*FM00568662*

Page 4: GENERAL DRAWINGS END OF ADDENDUM - Purchasing

Page 3 of 3

08-SEP-16

08-SEP-16

ASBESTOS SUMMARY FOR WARDLAW COLLEGE (080) – SEPTEMBER 2016

CRAWL SPACE MAY BE CONTAMINATED WITH ASBESTOS

ASBESTOS HAS BEEN FOUND IN THIS BUILDING. IF DISTURBED, ASBESTOS MAY BE HARMFUL TO YOUR HEALTH.

PLEASE DO NOT DISTURB THE FOLLOWING MATERIALS IN THIS BUILDING AS THEY HAVE BEEN FOUND TO CONTAIN ASBESTOS.

- JOINT COMPOUND / SHEETROCK (3RD FLOOR ONLY)- 9X9 FLOOR TILE- BLACK MASTIC UNDER FLOOR TILE- RESIDUAL BLACK MASTIC ON FLOORING- BLACK DUCT MASTIC- PIPE INSULATION- BLACK MASTIC ON PIPE INSULATION- RED FIRE CAULKING

IF A BUILDING MATERIAL IS NOT LISTED, DO NOT ASSUME THAT IT DOES NOT CONTAIN ASBESTOS. IT MAY NOT HAVE BEEN TESTED.

FOR FURTHER INFORMATION, PLEASE CONTACT THE USC HAZMAT PROGRAM.

THE SOIL IN CRAWL SPACES MAY BE CONTAMINATED WITH ASBESTOS FROM OLD PIPE INSULATION AND OTHER MATERIALS. PLEASE CONTACT THE USC HAZMAT PROGRAM BEFORE ENTERING THESE CRAWL SPACES.

SHOULD BE FIELD VERIFIED FOR ALL OTHER PURPOSES INCLUDING ABATEMENT. THIS SURVEY IS ONLY VALID FOR THE DESIGNATED AREA(S)/LOCATION(S) TESTED IE: SECTIONS A, B, C, D, E, F ; WARDLAW COLLEGE (ROOF).

FM00568662 USC Work Order*FM00568662*

Page 5: GENERAL DRAWINGS END OF ADDENDUM - Purchasing

OrderID: 021904909

Page 1 Of 2

Page 6: GENERAL DRAWINGS END OF ADDENDUM - Purchasing

OrderID: 021904909

Page 2 Of 2

Page 7: GENERAL DRAWINGS END OF ADDENDUM - Purchasing

EMSL Analytical, Inc.706 Gralin Street Kernersville, NC 27284

Tel/Fax: (336) 992-1025 / (336) 992-4175

http://www.EMSL.com / [email protected]

021904909EMSL Order:

Customer ID: UNSC62

Customer PO: 2000041931

Project ID:

Attention: Phone:USC Hazmat (803) 777-7000

Fax:University of South Carolina (803) 777-3990

Received Date:743 Greene Street 07/22/2019 10:15 AM

Analysis Date:Columbia, SC 29208 07/22/2019

Collected Date: 07/19/2019

Project: 080 Wardlaw College

Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized

Light Microscopy

Sample Description Appearance % Fibrous % Non-Fibrous

Non-Asbestos Asbestos

% Type

1

021904909-0001

None DetectedQuartz

Ca Carbonate

Non-fibrous (Other)

25%

20%

55%

Cellulose<1%Gray/White

Non-Fibrous

Homogeneous

Stucco

2

021904909-0002

None DetectedQuartz

Ca Carbonate

Non-fibrous (Other)

30%

20%

50%

Cellulose<1%Gray

Non-Fibrous

Homogeneous

Stucco

3

021904909-0003

None DetectedCa Carbonate

Non-fibrous (Other)

30%

70%

Cellulose<1%Gray/White

Non-Fibrous

Homogeneous

Stucco

4

021904909-0004

None DetectedQuartz

Ca Carbonate

Non-fibrous (Other)

30%

20%

50%

Cellulose<1%Gray

Non-Fibrous

Homogeneous

Stucco

5

021904909-0005

None DetectedQuartz

Ca Carbonate

Non-fibrous (Other)

30%

20%

50%

Cellulose<1%Gray

Non-Fibrous

Homogeneous

Stucco

6

021904909-0006

None DetectedCa Carbonate

Non-fibrous (Other)

30%

70%

Cellulose<1%Gray/White

Non-Fibrous

Homogeneous

Stucco

7

021904909-0007

None DetectedQuartz

Ca Carbonate

Non-fibrous (Other)

30%

20%

50%

Cellulose<1%Gray

Non-Fibrous

Homogeneous

Stucco

Analyst(s)

Cameron Evans (5)

Ryan Rains (2)

Stephen Bennett, Laboratory Manager

or Other Approved Signatory

EMSL maintains liability limited to cost of analysis . The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 "Interim

Method"), but augmented with procedures outlined in the 1993 ("final") version of the method. This report relates only to the samples reported above, and may not be reproduced, except in full, without

written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . Interpretation and use of test results are the responsibility of the client. All

samples received in acceptable condition unless otherwise noted. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of

the federal government. EMSL recommends gravimetric reduction for all non -friable organically bound materials prior to analysis. Estimation of uncertainty is available on request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC NVLAP Lab Code 102104-0, CA ELAP 2689, Virginia 3333-000228, West Virginia LT000321

Initial report from: 07/22/2019 17:16:39

Page 1 of 1ASB_PLM_0008_0001 - 1.78 Printed: 7/22/2019 5:16 PM

Page 8: GENERAL DRAWINGS END OF ADDENDUM - Purchasing

Project Location

University of South CarolinaWARDLAW COLLEGE ROOFREPLACEMENT PROJECTSTATE PROJECT No.: 50003317-2Project Address820 SUMTER STREETCOLUMBIA, SOUTH CAROLINA 29208

VICINITY MAP

SITE LOCATION

Abbreviations

Details / Elevations / Sections Identifier

MAX.

MIN.

N.I.C

NTS

O.C.

O.H

TYP.

SIM.

MAXIMUM

MINIMUM

NOT IN CONTRACT

NOT TO SCALE

ON CENTER

OPPOSITE HAND

TYPICAL

SIMILAR

XXXX

ELEVATION / DETAIL / SECTION LABEL

SHEET SHOWN ON

GeneralG-101 COVER SHEET

ArchitecturalA-101 ROOF PLANA-102 ROOF PLAN: WIND ZONESA-103 ROOF PLAN: WALKPAD LAYOUTA-502 ROOF DETAILSA-503 ROOF DETAILSA-504 ROOF DETAILSA-505 ROOF DETAILSA-506 ROOF DETAILSA-507 ROOF DETAILSA-508 ROOF DETAILSA-509 ROOF DETAILS AND

SMACNA DETAILS

Structural (Alternate No.2)S-100 STRUCTURAL GENERAL NOTESS-101 ENLARGED ROOF PLAN AREA FS-200 ELEVATIONS AND DETAILSS-201 SECTIONS AND DETAILS

Index of Drawings

SHADING IDENTIFIES EXISTING

CONDITIONS AND NOT IN SCOPE OF WORK

PROJECT SITE

LOCATION

Consulting Engineers and Scientists

CLIENT

UNIVERSITY of SOUTH CAROLINA743 Greene StreetColumbia, South Carolina

Mr. Dale Branhame: [email protected]: 803.777.1288

ENGINEERING CONSULTANT

TERRACON CONSULTANTS, INC.2701 Westport RoadCharlotte, North Carolina

Mr. Stewart S. Swing, RRO, E.I.Senior Staff Engineer I Facilitiese: [email protected]: 704.594.8905

PROJECT NAME AND ADDRESS:

ISSUE DATE:

DESIGNED BY:

TERRACON'S PROJECT NUMBER:

PROJECT TEAM:

APR REVIEWER:

DRAWN BY:

SSS

LTH

FH186084

ISSUE FOR:

ADDENDUM:No.: DATE: DESCRIPTION:

SHEET NUMBER:

07.03.2019

TITLE SHEET:

Unive

rsity o

f Sou

th Ca

rolina

WARD

LAW

COLL

EGE

ROOF

REPL

ACEM

ENT P

ROJE

CTST

ATE P

ROJE

CT No

.: 500

0331

7-2Pro

ject A

ddres

s:82

0 Sou

th Ma

in Stre

etCo

lumbia

, Sou

th Ca

rolina

2920

8

EGM II

ENGINEER STATE LICENSE SEAL

ISSUED FOR BIDDING

Consulting Engineers and Scientists

2701 Westport Road

Charlotte, North Carolina

p: 704.509.1777

terracon.com

Project No. FH186084

Terracon SC License No. 2220

G-101

COVER SHEET

2 7/23/19 ADDED WALKPADREQUIREMENTS

2

Page 9: GENERAL DRAWINGS END OF ADDENDUM - Purchasing

26'-0"

61'-0"

74

'-6

"2

3'-8

"

98'-9" 64'-6"

4'-3

"

101'-0" 25'-0"

77

'-1

0"

26'-0"

20'-11

1

2

"14'-3"

30

'-8

"

45

'-6

"

SV

SV

SV

SCP

ELEVATED HVAC

SCP

ON STEEL PLATFORMDP

SLT

SLT

EB

SLT SLTEB EB

SCP

SCP

SLT

EB

SL

SV

RD

SV

SV

ELEVATED HVACON STEEL PLATFORM

RD RD

RD RD

RD

RD

NOSNOS

NOS NOS

NOSNOSNOS

RD

RD

RD

RD

NOS NOS

NOS

NOS

NOS

NOS

NOS

NOS NOS

NOSNOS

RD

RD

RIDGE LINE

RIDG

E LIN

E

RD

RD

RD

NOS

NOS

NOS

NOS

RDRD

RDRD

NOS

NOS NOS

NOS

RIDGE LINE

ROOF AREA BMETAL DECK

101'-1"

ROOF AREA C3CONCRETE DECK

METAL STAIRS

CONDENSATELINE (TYP.)

CORNICE

ELECTRICALCONDUIT

ELECTRICALCONDUIT

CORNICE

CORNICE

ELECTRICALCONDUIT

STAIRS

ELEVATEDDUCT (TYP.)

ELECTRICALCONDUIT (TYP.)

CORNICE

CORNICE

DS

DS

SV SV

CCCC

CCSV

CORNICE

CONDENSATELINE (TYP.)

25A-506

24A-506

26A-507

23A-506

10A-503

TYP.

7A-502

SIM.

26A-507

9A-503

27A-507

28A-507

TYP.

2A-501

1A-501

4A-501

4aA-501

TYP.

8A-502

3A-501

5A-502

6A-502

7A-502

9A-503

16A-504

22A-506

18A-505

37A-509

17A-505

19A-505

11A-503

12A-503

ROOF AREA C4CONCRETE DECK

15A-504

15A-504SIM.

33A-508

TYP.SIM.

TYP.

30A-508

TYP.

32A-508

34A-508

TYP.

34A-508

TYP.

32A-508

31A-508

31A-508

TYP.SIM.

ROOF AREA ELIGHTWEIGHT

CONCRETE DECK

30A-508

TYP. TYP.

TYP.

TYP.

TYP.

SIM.

TYP.

33A-508

31A-508

TYP.SIM.

31A-508TYP.SIM.

34A-508

TYP.

35A-508

TYP.

35A-508

30A-508

TYP.

ROOF AREA ACONCRETE DECK

ROOF AREA C1CONCRETE DECK

ROOF AREA C2CONCRETE DECK

ROOF AREA FCONCRETE DECK

ROOF AREA DCONCRETE DECK

20A-505

6 WINDOWLOCATIONS

37A-509

6 WINDOWLOCATIONS

(OPP.)

34A-508

13A-504

9A-503

SIM.

ROOF AREA GNOT IN CONTRACT

14A-504

13A-504

SIM.

13A-504

35A-508

23A-506

DS

A-101

PROJECT NAME AND ADDRESS:

ISSUE DATE:

DESIGNED BY:

TERRACON'S PROJECT NUMBER:

PROJECT TEAM:

APR REVIEWER:

DRAWN BY:

SSS

LTH

FH186084

ISSUE FOR:

ADDENDUM:No.: DATE: DESCRIPTION:

SHEET NUMBER:

07.03.2019

TITLE SHEET:

Unive

rsity o

f Sou

th Ca

rolina

WARD

LAW

COLL

EGE

ROOF

REPL

ACEM

ENT P

ROJE

CTST

ATE P

ROJE

CT No

.: 500

0331

7-2Pro

ject A

ddres

s:82

0 Sou

th Ma

in Stre

etCo

lumbia

, Sou

th Ca

rolina

2920

8

EGM II

ENGINEER STATE LICENSE SEAL

ISSUED FOR BIDDING

Consulting Engineers and Scientists

2701 Westport Road

Charlotte, North Carolina

p: 704.509.1777

terracon.com

Project No. FH186084

Terracon SC License No. 2220

ROOF PLAN

1

WARDLAW COLLEGE ROOF PLAN

SCALE: 1/16" = 1'-0"

LEGEND

RD

CONSTRUCTION NOTES

SV

1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS ANDDIMENSIONS.

2. ELECTRICAL CONDUITS, BOXES ,OUTLET AND CABLES MAY REQUIREPOWER TO BE DISCONNECTED PRIOR TO PERFORMING THE WORK.CONTRACTOR TO COORDINATE WITH OWNER PRIOR TO REMOVAL.

3. ABANDONED EQUIPMENT TRUSSES AND POURABLE SEALER SHOULDBE REMOVED AND DISCARDED.

4. RAISE ALL CURBS TO ACHIEVE AN 8" MINIMUM FLASHING HEIGHT.

5. CLEAN, PRIME AND PAINT BIRD HOUSES AT ROOF AREAS A, C AND D.

6. STAIRS AT ROOF AREA C3 WILL NEED TO BE REMOVED ANDREINSTALLED ONCE NEW ROOF INSTALLATION IS COMPLETED.

7. ALL EQUIPMENT SUPPORTS AND PIPE PENETRATIONS ARE TO BELIQUID FLASHED.

8. EXISTING DRAIN INSERTS WILL NEED TO BE REMOVED AT ALLDRAINS TO ALLOW FOR NEW RETRO-FIT INSERT.

9. MECHANICAL UNIT STRUTS THAT ARE ATTACHED TO PARAPET WALLWILL NEED TO BE REMOVED, STORED AND REINSTALLED ONCE NEWROOFING IS COMPLETED. STRUTS TO BE FLASHED WITH NEW LIQUIDAPPLIED FLASHING.

10. NEW CONCRETE PAD AND DOORS TO BE INSTALLED AT ROOF AREASA AND D.

11. BASE FLASHING HEIGHTS WILL VARY AT SECTIONS WHERE WALLMETAL PANELS ARE TO HAVE CONSISTENT HEIGHT.

12. ROOF AREA C2 WILL NEED CONCRETE REPAIR WORK AT WALLS TOCOMPLETE NEW ROOFING INSTALLATION.

13. PULL TEST AT LIGHTWEIGHT CONCRETE DECK SHOULD BECONDUCTED PRIOR TO NEW ROOFING INSTALLATION.

14. CRICKETS SHOULD BE INSTALLED AT ALL CURBS THAT EXCEED 24"INCHES IN WIDTH.

15. CONTRACTOR TO REMOVE AND INSTALL NEW COPING CAP AT ROOFAREA G TO ACCOMMODATE NEW PARAPET WALL HEIGHT AT ROOFAREA B.

16. PROVIDE SUPPORTS FOR ALL CONDUIT, PIPES, AND CONDENSATIONLINES. ALL SUPPORTS SHOULD BE SET ON WALKPADS.

17. ON ANY ROOF AREA THAT A DOWNSPOUT IS TO BE INSTALLED, THEDOWNSPOUT SHOULD EXTEND TO THE NEAREST ROOF DRAIN ANDBE SUPPORTED. SUPPORTS SHOULD BE INSTALLED OVER WALKPADS.

TAPERED INSULATION

TAPERED SLOPE DIRECTION

STRUCTURAL SLOPE

ROOF DRAIN

SANITARY VENT

EQUIPMENT UNIT

PARAPET WALL/CORNICE

ELEVATED DUCT

SCUPPER

SKYLIGHT

EQUIPMENT SUPPORT

VENTILATOR

COVERED CURB

SECURITY LIGHT

ELECTRICAL BOX

NEW OVERFLOW SCUPPER

GUTTER/DOWNSPOUT

DUCT SUPPORT PEDESTAL

DETAIL FLAG No. #

NOT IN CONTRACT

SCP

LS

CC

SLT

EB

NOSDS

ALTERNATE No.1:(TYPICAL ON ALL SHEETS)1. INSTALL ROOFING SYSTEM UTILIZING ADHESIVE, AND

COLD APPLIED - ADHESIVE IN LIEU OF HOT-APPLIEDASPHALT.

1. RE-ROOFING OF ROOF AREAS A, B, C1, C2, C3, C4, D, E AND Fa. LOW SLOPE ROOF AREAS TO RECEIVE NEW TWO-PLY MODIFIED

BITUMEN ROOFING SYSTEM.b. ROOF AREA C2 TO RECEIVE LIQUID PMMA ROOFING SYSTEM.

2. COATING OF VENTS (BIRDHOUSES) AT ROOF AREAS A, C, AND D.

3. WALL PANEL INSTALLATION AT AREAS A, C, D, AND E.

4. SEALANT INSTALLATION AT WINDOW PERIMETER.

5. MISCELLANEOUS WORK INCLUDES, BUT IS NOT LIMITED TO, THE INSTALLATIONOF EDGE METAL, COPING, NEW OVERFLOW SCUPPERS, RETROFIT ROOF DRAINS,GUTTERS, DOORS, DOWNSPOUTS, AND FLASHING.

6. REMOVE AND REPLACE STUCCO (TO MATCH EXISTING) AT ROOF AREA F.

BASE BID:

N

SCOPE OF WORKNOT IN SCOPE OF WORK

KEY PLAN

ROOF AREA B

ROOF AREA A

ROOF AREA C2

ROOF AREA C3

ROOF AREA C4

ROOF AREA C

ROOF AREA D

ROOF AREA F

ROOF AREA E

2 7/23/19 ADDED WALKPADREQUIREMENTS

2

Page 10: GENERAL DRAWINGS END OF ADDENDUM - Purchasing

26'-0"

61'-0"

74

'-6

"2

3'-8

"

98'-9" 64'-6"

4'-3

"

101'-0" 25'-0"

77

'-1

0"

26'-0"

20'-11

1

2

"14'-3"

30

'-8

"

45

'-6

"

SV

SV

SV

SCP

ELEVATED HVAC

SCP

ON STEEL PLATFORMDP

SLT

SLT

EB

SLT SLTEB EB

SCP

SCP

SLT

EB

SL

SV

RD

SV

SV

ELEVATED HVACON STEEL PLATFORM

RD RD

RD RD

RD

RD

NOSNOS

RD

RD

RD

RD

NOS

NOS

NOS

NOS

NOS NOS

RD

RD

RD

RD

RD

RDRD

RDRD

ROOF AREA BMETAL DECK

101'-1"

ROOF AREA C3CONCRETE DECK

SV SV

CCCC

CCSV

ROOF AREA C4CONCRETE DECK

ROOF AREA ELIGHTWEIGHT

CONCRETE DECK

ROOF AREA ACONCRETE DECK

ROOF AREA C1CONCRETE DECK

ROOF AREA C2CONCRETE DECK

ROOF AREA FCONCRETE DECK

ROOF AREA DCONCRETE DECK

ROOF AREA GNOT IN CONTRACT

A-103

PROJECT NAME AND ADDRESS:

ISSUE DATE:

DESIGNED BY:

TERRACON'S PROJECT NUMBER:

PROJECT TEAM:

APR REVIEWER:

DRAWN BY:

SSS

LTH

FH186084

ISSUE FOR:

ADDENDUM:No.: DATE: DESCRIPTION:

SHEET NUMBER:

07.03.2019

TITLE SHEET:

Unive

rsity o

f Sou

th Ca

rolina

WARD

LAW

COLL

EGE

ROOF

REPL

ACEM

ENT P

ROJE

CTST

ATE P

ROJE

CT No

.: 500

0331

7-2Pro

ject A

ddres

s:82

0 Sou

th Ma

in Stre

etCo

lumbia

, Sou

th Ca

rolina

2920

8

EGM II

ENGINEER STATE LICENSE SEAL

ISSUED FOR BIDDING

Consulting Engineers and Scientists

2701 Westport Road

Charlotte, North Carolina

p: 704.509.1777

terracon.com

Project No. FH186084

Terracon SC License No. 2220

1

WARDLAW COLLEGE WALKPAD LAYOUT PLAN

SCALE: 1/16" = 1'-0"

LEGEND

RD

CONSTRUCTION NOTES

SV

1. PROVIDE SUPPORTS FOR ALL CONDUIT, PIPES, AND CONDENSATIONLINES. ALL SUPPORTS SHOULD BE SET ON WALKPADS.

2. ON ANY ROOF AREA THAT A DOWNSPOUT IS TO BE INSTALLED, THEDOWNSPOUT SHOULD EXTEND TO THE NEAREST ROOF DRAIN ANDBE SUPPORTED. SUPPORTS SHOULD BE INSTALLED OVER WALKPADS.

NEW WALKPADS

ROOF DRAIN

SANITARY VENT

EQUIPMENT UNIT

PARAPET WALL/CORNICE

ELEVATED DUCT

SCUPPER

SKYLIGHT

EQUIPMENT SUPPORT

VENTILATOR

COVERED CURB

SECURITY LIGHT

ELECTRICAL BOX

NEW OVERFLOW SCUPPER

GUTTER/DOWNSPOUT

DUCT SUPPORT PEDESTAL

NOT IN CONTRACT

SCP

LS

CC

SLT

EB

NOSDS

1. RE-ROOFING OF ROOF AREAS A, B, C1, C2, C3, C4, D, E AND Fa. LOW SLOPE ROOF AREAS TO RECEIVE NEW TWO-PLY MODIFIED

BITUMEN ROOFING SYSTEM.b. ROOF AREA C2 TO RECEIVE LIQUID PMMA ROOFING SYSTEM.

2. COATING OF VENTS (BIRDHOUSES) AT ROOF AREAS A, C, AND D.

3. WALL PANEL INSTALLATION AT AREAS A, C, D, AND E.

4. SEALANT INSTALLATION AT WINDOW PERIMETER.

5. MISCELLANEOUS WORK INCLUDES, BUT IS NOT LIMITED TO, THE INSTALLATIONOF EDGE METAL, COPING, NEW OVERFLOW SCUPPERS, RETROFIT ROOF DRAINS,GUTTERS, DOORS, DOWNSPOUTS, AND FLASHING.

6. REMOVE AND REPLACE STUCCO (TO MATCH EXISTING) AT ROOF AREA F.

BASE BID:

N

SCOPE OF WORKNOT IN SCOPE OF WORK

KEY PLAN

ROOF AREA B

ROOF AREA A

ROOF AREA C2

ROOF AREA C3

ROOF AREA C4

ROOF AREA C

ROOF AREA D

ROOF AREA F

ROOF AREA E

2 7/23/19 ADDED WALKPADREQUIREMENTS

ROOF PLAN:

WALKPAD LAYOUT PLAN