Upload
others
View
20
Download
2
Embed Size (px)
Citation preview
Tormax iMotion ® TN 110 In-Floor Swing Door Operator
Installation/Facilitation Guidelines
Center Pivot Application – Right Hand Operator w/ Flush Mounted Box
General Contractors
Table of Contents
Door Fabrication Details 1-2
Electrical Details 3-5
Masonry/Pit Details 6-7
REV - (09/12)
TORMAX TECHNOLOGIES INC.
DOOR FABRICATION DETAILSNOTE: " * * " - INDICATES COMPONENT IS JOB SPECIFIC OR OPTIONAL
REV - 09/12
CENTER PIVOTDOOR SHOE
TN OPERATOR ASSY
BOX
WEEP DRAIN
TN OPERATOR ARM
DOOR
PIT
JAMB
(TERRAZZO) COVERFLUSH MOUNT
CONTROL BOX
ACCESSIBLE HOLE FOR WIRING
NOT ACCESSIBLE
*SEE ELECTRICAL DETAILS FOR INTERNAL CLEARANCE
*FUNCTIONCONTROL
PANEL*
*JB**JB*
15 AMPS MIN110 VAC
50-60 HZ
RIGHT HAND CENTER PIVOT
TORMAX TECHNOLOGIES INC.REV - 09/12
TYP
DO
OR
CE
NTE
R P
IVO
TD
OO
R S
HO
E
TN O
PE
RA
TOR
AR
M
JAM
B
AA
C LO
F D
OO
R
Dril
l & T
ap M
8x1.
25, x
1" (
5 P
lace
s)
OR
Inst
all 5
x Th
read
ed In
sert
with
M
8x1.
25 T
hrea
ds in
Doo
r Onl
y
C LPI
VOT
*TBD
2 3/
4 R
EF5
1/8
3 15
/16
TYP
4 P
lace
s
PIVO
TLC
SE
CTI
ON
A-A
JAM
BD
OO
RTN
OP
ER
ATO
RA
RM
DO
OR
(RE
F O
NLY
)
(REF
ON
LY)
1 3/
8
(TN
OPE
RA
TOR
AR
M N
OT
SH
OW
N F
OR
CLA
RIT
Y)
JAM
B(R
EF O
NLY
)
DO
OR
FA
BR
ICA
TIO
N D
ETA
ILS
B B
1 13
/16
MIN
SE
CTI
ON
B-B
SCA
LE: 2
/1
1 3/
81
1/2
25 1
/8 C
hann
el L
engt
h
2 5/
8 R
EF
PIV
OT
PIV
OT
PIV
OT
1 25
/32
RE
F
TORMAX TECHNOLOGIES INC.
ELECTRICAL DETAILSNOTE: " * * " - INDICATES COMPONENT IS JOB SPECIFIC OR OPTIONAL
REV - 09/12
RIGHT HAND CENTER PIVOT
JAMB
CONTROL BOX
PIT
ACCESSIBLE HOLE FOR WIRING
NOT ACCESSIBLE
*SEE ELECTRICAL DETAILS FOR INTERNAL CLEARANCE
DOOR
TN OPERATOR ARM
WEEP DRAIN
BOX
TN OPERATOR ASSY
DOOR SHOECENTER PIVOT
(TERRAZZO) COVERFLUSH MOUNT
110 VAC
*JB**JB*
*FUNCTIONCONTROL
PANEL*
50-60 HZ15 AMPS MIN
TORMAX TECHNOLOGIES INC.
ELECTRICAL DETAILS
REV - 09/12
110V AC (IN)
24V DCTO ACT.
SWITCHES
*JB**JB*
*FUNCTIONCONTROL
PANEL*
*TN110CONTROL
BOX*
TO TN110OPERATOR
ACCESSIBLE HOLE FOR WIRING
NOT ACCESSIBLE
ENCODER CABLE
MOTORCABLE
NOTES:(1) " * *" INDICATES JOB SPECIFIC LOCATION. CONSULT GC FOR FURTHER DETAILS.(2) REF NEXT PAGE (ELECTRICAL DETAILS, SHT 3) FOR WIRING DETAILS.(3) REF TN110 OPERATION MANUAL (P/N: US801461) FOR ADDITIONAL INFORMATION.(4) INSTALLATION AND WIRING PRACTICES MUST COMPLY WITH LOCAL CODES.
Ø MAX. 1-5/16"
Ø MIN. 15/16"
10 AMPSLINBUS CABLE 75'-0" SUPPLIED BY TORMAX
TORMAX TECHNOLOGIES INC.REV - 09/12
pwmOUT40V
out1OUT24V SW2
RS232
LIN-BUS
out2OUT24V
n1GND24V N
n2GND24V N
n3GND24V N
n4GND24V N
GN
DN
24
V
OU
T
GN
DN
24V
OU
T
sf1sf2
GN
DN
24V
LN
GN
DN
24
V
OU
T
sf3sf4
123456
123456
123456
12345678
12345678
LIN-BUS
CANBUS GN
DLH
24
V
CANBUS GN
DLH
24V
Mo
tor
Enc
oder
OU
T
GN
D24
VA
BC
LIN
VTM
PG
ND
BR
UW
+
EncoderMotor
PowerSupply
Bra
keSe
lect
Le n
code
rM
mot
or
HW
Eti k
ette
HW
Etk
ette
CA
RD
24V
5VB
rake
Jum
per
max
none
mn
1
234
1 1
Enc
oder
Mot
or
12
34
56
12
34
56
7
24 VABCGNDLIN
TMPGNDBRUVWGND
12
34
56
12
34
56
7
24 VABCGNDLIN
TMPGNDBRUVWGND
Do
not g
roun
d sh
ield
of
enco
der c
able
at t
he o
pera
tor
Gro
und
scre
en o
fm
otor
cab
le in
scre
w c
onne
ctio
n
Enco
der c
able
Mot
or c
able
PN
: US
8013
7820
aw
g, s
hiel
ded,
6 co
nduc
tor,
stra
nded
wire
.M
ax 8
2’
PN: U
S801
379
14 a
wg,
shi
elde
d,7
cond
ucto
r, st
rand
ed w
ireM
ax 8
2’
cabl
eØ
5/16
”22
/24
mm
cabl
eØ
11/3
2”24
/27
mm
cabl
e Ø
15/3
2”27
/30
mm
ca
ble
Ø1
- 5/1
6”
enco
der a
nd m
otor
grou
ndin
g br
acke
ts
(see
cab
le p
lan
for c
ondu
it sp
ecifi
catio
ns)
Leng
th =
82'
Max
Botto
m V
iew
Of C
ontro
l Box11
0 V
AC
4 3 2m
eo
xam
Jum
per
ekra
BV5
V42D
CAR
eetk
EH
W
eek
Eti
HW
oto
mM
ode
ce
L
Brak
eSe
lect
y pl up Sr e wo P
r o ot Mr e od nc E
+
WU
RBD
GN
PTM
VN
LIC
BA
V42
DGN
TUO
edoEn
ctooM
V42
H L DN
GSUB CAN
V42
H L DNGSUB CAN
SUB N- L
8 7 6 5 4 3 2
8 7 6 5 4 3 2
6 5 4 3 2
6 5 4 3 2
6 5 4 3 2
4 s 3 s
TUO
V42
N DN
G
NL
V42
N DN
G
2 s s
TU
O
V42
N DNG
TU
O
V42
N DNG
NV 42 DNG4
NV 42 DNG3
NV 42 DNG2
NV 42 DNG
V 42 T UO2 o
SUB N- L
2 RS23
2 SWV 42 T UOo
V04 T UOmwp
TN11
0 C
ON
TRO
L BO
X
115V
AC
(108
-125
V)
AC
230V
(198
-264
V)
50/6
0 H
z
N 1
NL23
0
115
15 A
MIN
Che
ck C
orre
ct P
ositi
onO
f Vol
tage
Sel
ecto
r
1 15/16
ELEC
TRIC
AL D
ETAI
LS
TORMAX TECHNOLOGIES INC.
PIT PREP DETAILSNOTE: " * * " - INDICATES COMPONENT IS JOB SPECIFIC OR OPTIONAL
REV - 09/12
RIGHT HAND CENTER PIVOT
JAMB
CONTROL BOX
PIT
ACCESSIBLE HOLE FOR WIRING
NOT ACCESSIBLE
*SEE ELECTRICAL DETAILS FOR INTERNAL CLEARANCE
DOOR
TN OPERATOR ARM
(TERRAZZO) COVERFLUSH MOUNT
WEEP DRAIN
BOX
TN OPERATOR ASSY
DOOR SHOECENTER PIVOT
110 VAC
*JB* *JB*
*FUNCTIONCONTROL
PANEL*
50-60 HZ15 AMPS MIN
TORMAX TECHNOLOGIES INC.REV - 09/12
WE
EP D
RA
IN
17 3
/4
19 3
/4
6 7/
8
CO
VE
R A
NY
UN
USE
D H
OLE
S A
RO
UN
D B
OX
AN
D F
ILL
OU
TER
PE
RIM
ETE
R W
ITH
MO
RTA
R.
!W
EEP
DR
AIN
MU
ST
BE IN
STA
LLE
DO
R M
AN
UFA
CTU
RE
R'S
WA
RR
AN
TYW
ILL
BE V
OID
.
NO
TES
:
2 7/
8
1 3/
16
WEE
P D
RA
IN
2 7/
8
(1) E
nsur
e pr
ovis
ions
for w
eep
drai
n an
d el
ectri
cal w
iring
hav
e be
en m
ade
prio
r to
fillin
g th
e pi
t with
mor
tar.
(2) W
eep
drai
n m
ust b
e in
stal
led
or m
anuf
actu
rer's
war
rant
y w
ill b
e vo
id.
(3) W
eep
drai
n ha
rdw
are
to b
e pr
ovid
ed b
y G
C. W
eep
drai
n in
stal
latio
n &
loca
tion
of te
rmin
atio
n m
ust c
ompl
y w
ith c
ity a
nd(o
r) s
tate
cod
es.
(4) *
* =
Job
spec
ific.
PIT
DIM
ENSI
ON
S:19
-3/4
" L x
17-
3/4"
W x
6-7
/8" D
FLU
SH
MO
UN
T B
OX
SH
OW
N F
OR
RE
FER
EN
CE
C LPI
VOT
C LPI
VOT
JAM
B
**P
IVO
T O
FFS
ET
BO
X LO
CA
TIO
N T
OLE
RA
NC
ES
ø1 5
/16
2 P
LAC
ES
INS
TALL
WE
EP
DR
AIN
IN E
ITH
ER
HO
LE
3 7/
8±1/
2
PIT
PR
EP
DET
AIL
S
OF
PIT
0±1/
4
LC
C LO
F PI
T
C LO
F B
OX
0±1/
2
PIVO
T