Upload
imediach
View
226
Download
0
Tags:
Embed Size (px)
DESCRIPTION
precision liquid handling
Citation preview
y o u r q u a l i t y p a r t n e r w o r l d w i d e
precision� volumetryElectronic micropipettes
Positive displacement pipettes
Digital setting micropipettes
Repeater pipette
Microdispenser pipettes
Low profile dispensers
Bottle-top dispensers
Laboratory syringes
Pipette controllers
Pipette tips / consumables
Work stations
Service center
Digital reading micropipettes
SOCOREX ISBA SAChamp-Colomb 7, P.O. Box 3781024 Ecublens/[email protected]. +41 (0)21 651 6000Fax +41 (0)21 651 6001
C.G
EN.E
�–�F
415
Your local distributor
Important information
Refer to package inserts for safety precautions, operating instructions and warranty terms.
User must pay special attentionto possible hand fatigue during serial pipetting and its medical consequences such as repetitive strain injuries (RSI).
Mind risks involved in handling hazardous liquids with respect to personal, third party andenvironmental protection and safety.
Products and specifications are subject to change without prior notice.
Copyright�©�2015�by�Socorex�Isba�SA,�Switzerland
20
15
-20
16
PR
EC
ISIO
N L
IQU
ID H
AN
DL
ING
liquid
Dear Partner in science,
This new Socorex 2015-2016 edition features a number of innovations you will enjoy discovering and using in your liquid dosing applications.
Made of sturdy materials, well thought out in terms of functions and metrological performance, the Calibrex™ organo and solutae bottle-top dispensers have rapidly and successfully proven themselves in the hands of demanding scientists.
Overcoming even tricky liquids, the new positive displacement micropipettes Acura® capillar 846 is a high performance instrument enabling trouble-free handling of viscous liquids, foaming solutions and volatile solvents.
Significant progress has been made with our long established international partner network, adding new forces where needed. Their details are listed in the Distributor section of our web site. Highly qualified, well documented and equipped to provide the best advice and technical support, they work hand in hand with the thousands of end-users trusting Socorex throughout the world.
I seize the opportunity to pay a special tribute to both communities for their loyalty and contribution to our successful growth over so many years.
Sincerely
Sylvain Christen, CEO
Products & services
Today’s manufacturing programme includes a wide variety of high precision instruments used for reliablymeasuring, dosing, transferring, dispensing and injecting liquids in a large number of applications.
Manual and electronic micropipettes, single and multichannel pipettors, repeater pipettes, dispensers, pipette controllers and re-usable syringes, together with their accessories, constitute the heart of the programme.
Each precision instrument bears its own serial number and passes a strict performance control attested by an individual QC certificate.
The Socorex Service Center offers a global repair and calibration programme. The choices range from basic maintenance to accredited calibrations of all micropipettes and dispensers according to ISO 17025 – whatever their brand.
Welcome to Socorex – a world of expertise in prec
Sylvain Christen, CEO
Laurence Louy-Drevici, Business Development
Jean-Pierre Uldry, Director of Engineering
Aurelie Stangoni, Customer Service
Beatriz Grasset, Sales Administration Manager
Tatjana Van Bogaert, CEO Assistant
Pascal Durand, Admin. and Finance Manager
Thérèse Valenziano, Customer Service
Cat. No. Page
521.623 24
521.705 24
521.706 24
525.025 22
525.025FC 22
525.050 22
525.050FC 22
525.100 22
525.100FC 22
525.350 24
525.706 24
530.025 22
530.025FC 22
530.050 22
530.050FC 22
530.100 22
530.100FC 22
800.0002 6
800.0002XS 6
800.0010 6
800.0010XS 6
800.0010Y 6
800.0010YXS 6
800.0020 6
800.0020XS 6
800.0050 6
800.0050XS 6
800.0100 6
800.0100XS 6
800.0200 6
800.0200XS 6
800.08.010 6
800.08.050 6
Socorex® Instruments US Patents
Acura® models 810, 815, 825, 826 XS, 835, 835F, 855, 865 7,204,163 B2
Acura® models 810, 815, 825, 826 XS, 835, 835F, 855, 926 XS, 936, 956 6,833,114 B1
Acura® models 826XS.0200, 826XS.1000 8,900,526 B2
Acura® models 926XS.0200, 926XS.1000
Calibrex ™ models 525, 530 Pending
Socorex® Calibra® ABF ™ Calibrex ™ Jet-Pen ™ Stepper ™
Isba® Qualitips® Acurex ™ Dosys ™ Justip ™
Acura® Socorex Stepper® bioproof ™ Ecostep ™ Profiller ™
Other brand names contained in this catalogue belong to their respective owners.
Cat. No. Page
800.08.200 6
800.08.350 6
800.1000 6
800.10000 6
800.1000XS 6
800.12.010 6
800.12.050 6
800.12.200 6
800.12.350 6
800.2000 6
800.5000 6
810.1100 13
815.0001 11
815.0005 11
815.0010 11
815.0010Y 11
815.0015 11
815.0020 11
815.0025 11
815.0030 11
815.0032 11
815.0040 11
815.0050 11
815.0060 11
815.0070 11
815.0075 11
815.0080 11
815.0090 11
815.0100 11
815.0120 11
815.0150 11
815.0200 11
815.0250 11
Cat. No. Page
815.0300 11
815.0400 11
815.0500 11
815.0600 11
815.0700 11
815.0750 11
815.0800 11
815.0900 11
815.1000 11
822.0002 14
822.0010 14
822.0010Y 14
822.0020 14
822.0100 14
822.0200 14
822.1000 14
825.0002 8
825.0010 8
825.0010Y 8
825.0020 8
825.0050 8
825.0100 8
825.0200 8
825.1000 8
825.TRIO.C 9
825.TRIO.J 9
825.TRIO.M 9
825.TRIO.O 9
825.TRIO.P 9
825.TRIO.S 9
825.TRIO.T 9
825.TRIO.V 9
826.0002 8
Cat. No. Page
826.0010 8
826.0010Y 8
826.0020 8
826.0050 8
826.0100 8
826.0200 8
826.1000 8
826.TWX.E 9
826.TWX.G 9
826.TWX.H 9
826.TWX.K 9
826.TWX.N 9
826.TWX.Q 9
832.02 14
832.10 14
835.02 10
835.05 10
835.02PP 10
835.05PP 10
835.10 10
835.F02 11
835.F02.5 11
835.F05 11
835.F10 11
835.TRIO.Y 9
841.005 16
841.025 16
841.050 16
841.100 16
841.200 16
852.08.010 15
852.08.100 15
852.08.200 15
Cat. No. Page
852.12.100 15
852.12.200 15
855.08.010 12
855.08.050 12
855.08.200 12
855.08.350 12
855.12.010 12
855.12.050 12
855.12.200 12
855.12.350 12
865.0050 18
865.0200 18
865.1000 18
900.901.48A 6
900.901.48E 6
900.901.48G 6
900.901.48U 6
900.916 30
900.920.48 6
900.922.48 6
900.946E 30
900.946G 30
900.946U 30
926.0002 6
926.0002E 6
926.0010 6
926.0010E 6
926.0010Y 6
926.0010YE 6
926.0020 6
926.0020E 6
926.0050 6
926.0050E 6
Cat. No. Page
926.0100 6
926.0100E 6
926.0200 6
926.0200E 6
926.1000 6
926.1000E 6
936.02 6
936.02E 6
936.05 6
936.05E 6
936.10 6
936.10E 6
956.08.010 6
956.08.010E 6
956.08.050 6
956.08.050E 6
956.08.200 6
956.08.200E 6
956.08.350 6
956.08.350E 6
956.12.010 6
956.12.010E 6
956.12.050 6
956.12.050E 6
956.12.200 6
956.12.200E 6
956.12.350 6
956.12.350E 6
GLP + Ø 24
GLT + Ø 24
NSP + Ø 24
NST + Ø 24
Patents and Trade marks
www.socorex.com
Brief history
Socorex Isba SA, often referred to as just Socorex per its original name, was first founded in the late 1940s. Two young watchmakers had identified the need for new types of quality syringes for medical applications. The products rapidly met international success. In search of synergies, the company subsequently merged with another firm, moved to the city of Lausanne on Lake Geneva, changed name to become Socorex Isba SA and finally, under a new family ownership, built up-to-date premises in Ecublens – we are in 1963. Fifty years later, still with the same shareholders, Socorex has grown its two distinct laboratory and animal health divisions, reflecting a long time strategic reconversion. An important 50 th anniversary year, 2013 marked the inauguration of a major facility improvement programme. This included the construction of a new administration building and production plant expansion. Enlarged, the modern site will support the company’s capacity to handle many more success stories in the future.
Our customers
We are proud to include virtuallyall private, industrial, academicand government laboratories asour customers.
Those are involved in routine research and educational activities in fields as diverse as lifesciences – such as biotechnology and molecular biology – medicine, chemistry, pharmacology, environment, agriculture, etc.
Scientists are served efficiently by the dedicated network of Socorex distributors. Selected amongst the best suppliers, they carry an inventory of our products and provide technical support, repair and calibration services.
Find your closest Socorex partners listed on www.socorex.com
Quality achievements
Socorex’s dedication to precision and quality has been an all-time tradition. Our commitment to manufacturing the most reliable instruments and offering the best services was formalised with the completion of the ISO 9001 and ISO 13485 Quality Management System certifications.
Product lines used in the In Vitro Diagnostics fields conform tothe IVD 98/79 EEC directive for medical devices and are CEcertified accordingly.
Instruments are designed to operate under national and international standards such as ISO 8655, GLP, GMP and NCCLS.
Warranty coverage is three years on all manual pipettors, two years on electronic pipettes, dispensers and repeaters.
Product range
Electronic micropipettes
Acura® electro
Digital reading micropipettes
Acura® manual and Acura® manual XS
Digital setting micropipettes
Calibra® digital
Positive displacement pipettes
Acura® positive
Repeater pipette
StepperTM / EcostepTM
Microdispenser pipettes
Acura® manual
Bottle-top dispensers
CalibrexTM digital
Low-profile dispensers
AcurexTMcompact
Laboratory syringes
DosysTM
Pipette tips / consumables
Qualitips®
Pipette controllers
ProfillerTM / ProfilletteTM
Work stations
Service center
3
7
14
16
17
18
19
20
26
31
30
37
39Jean-Marc Ammann, Qualityand Regulatory Affairs Manager
Yves Liechti,Logistics Manager
Stephanie Boegli,Service Center
Christele Donze,Customer Service
Pascal Forestier, Technical Support Manager
Susanne Henry, Communication Project Manager
Yves Lachavanne, Marketing and Sales Support Manager
AN
DE
FR
IT
ESPT
AN
DE
FR
IT
ESPT
ision liquid handling
The Acura® electro models926XS micro, 936 macro, 956 multi
Product advantages nOptimal ergonomics, light weightnEasy, intuitive, self-teaching programmenLarge display, reversible for right or left readingnSwift-interchange battery packnFast charge, long working autonomynAdjustable tip ejector* fitting most tipsnPipetting cycle countern27 interchangeable volumetric modules all fitting same control unit * Socorex patented
Natural ergonomicsThe Acura® electro offers shape, balance and working ergonomics resembling those of a manual instrument. But comfort is so greatly improved that pipetting and result consistency are just outstanding.
Unique “right or left”display readingDisplay converts instantly to right or left side reading. All information clearly presented and visible at a glance during programming, pipetting and calibration steps.
Variable working speedLocated on the front side, speed selector allows swift change even during the pipetting process. In addition, slow speed access at any time by gentle touch of start button.
Pipetting cycle counter A simple double click gives access to the number of pipetting cycles performed since last zeroing.
Tip ejection – easier than everMaximal efficiency obtained with a large surface, ergonomically located ejector button. The shaft height adjustment system called JustipTM (4 mm span) - controlled by efficient click-stops - allows a wide selection of tips to tightly fit the nozzle.
The multichannel bowed shape ejector head permits effortless, sequential tip ejection.
Latest up-grade of a successful line making electronic pipetting simpler and safer than ever. The microprocessor-controlled instrument includes intuitive software avoiding any complicated programming steps. No particular skills are required to get quick access to six working modes and many volumes to select from. Two-year warranty.
3
2 3 4 51
1
2
3 5
4
AN
DE
FR
IT
ESPT
electronic micropipettesAcura®electro
Long working autonomy NiMH battery pack exchangeable instantly. Fast battery charging (< 1.5 hours) and extended working autonomy (> 3000 consecutive pipetting cycles). Battery charge level clearly visible on display. Automatic energy saving stand-by when unused.
Interchangeable volumetric modules One control unit fits a choice of 27 volumetric assemblies available separately. This greatly extends working possibilities and makes electronic pipetting affordable to all budgets. Disassembling and re-assembling without any tool contributes towards maximal flexibility.Calibration specificities of extra modules - as set by factory QC or by pipette owner - are retained in instrument memory.
Great built-in working flexibilitySurf through mode selection by pressing a single button.
Forward modeAspiration and pipetting of set volume. Suitable for all applications.
Reverse modeAspiration in excess, followed by dosing of set volume. Enhances reproducibility below 20 µL. Especially recommended for viscous and foaming liquids.
Stepper modeTip filling and step-by-step distribution. Best suited to aliquot samples.
Dilution modeAspiration of 2 or 3 different volumes for restitution in one shot. An easy way to dilute samples.
Tactile mode“Start and stop” liquid measurement, titration and gel loading by simple touch of activation button.
Mixing“Up and down” liquid flow in the tip / vial.
Pipette charging stand Stand allows charging and storing up to three electronic pipettes or battery packs simultaneously. Each position is fitted with a red/green charging LED. One stand supplied with every initial package.
Battery charging rack Space saving stand holds up to three battery packs simultaneously. The ideal charging and storage accessory for spare batteries, available at any time.
CalibrationControl software gives immediate access to calibration menu. Performance check possible over two or three independent volumes (Vmin, Vmid and Vmax). New settings entered directly from the keyboard.Error message warns of any inaccurate plunger movement.
4
www.socorex.com
4
4
3
3
5
5
ENERGY STAR®
qualified powersupply for a betterenvironment
2
1
1 2
5
Nozzle protection filter Macro models accommodate a filter protecting instrument against liquid overflow and contamination. Located in the nozzle, it can be removed and changed easily.
Pasteur pipette - straw tip adapters Optional accessories fit 2 mL glass Pasteur pipettes or 5 mL straw tip instead of Polypropylene tips.
Optimal working position 360° rotation of multichannel volumetric modules allows selection of the best working position.
Time efficient maintenancePipette construction limits maintenance to a minimum - no tool required to remove volumetric module. The pipetting cycle counter facilitates maintenance monitoring.
Whenever sterilisation is needed, volumetric modules can be autoclaved at 121°C / 250°F.
Initial package Recommended when purchasing an Acura® electro for the first time, each initial package contains one electronic pipette, QC certificate and operating instructions, charging stand, power supply, additional battery pack, Qualitips® pipette tips samples. Thereafter, additional pipettes can be purchased alone and charged on existing stand.
2 3 41
1
2
3 5
4
5
926XSmicro
0.1 - 2 µL0.5 – 10 µL
1 - 20 µL2.5 - 50 µL5 - 100 µL
10 - 200 µL50 - 1000 µL
936macro
0.1 - 2 mL0.25 - 5 mL0.5 - 10 mL
956multi
0.5 - 10 µL2.5 - 50 µL10 - 200 µL20 - 350 µL
The Acura® electro product advantages
MicropipettesnReduced shaft length and conical end improve driveabilitynEasy access to microtubes and microplatesnOptional longer volumetric modulesnSimple conversion by user at any timenUnsurpassed metrological performance and stability
MacropipettesnInterchangeable nozzle protection filternAdapters for Pasteur pipette and straw tipsnOutstanding accuracy and precision
MultichannelnLarge selection of 8- and 12-channel modelsnLight weight and perfect hand fittingnSequential tip ejectionnAlso fit any single channel volumetric module
electronic micro- macro and multichannel pipettesAcura®electro
www.socorex.com
0.1 – 2 µL0.5 - 10 µL0.5 - 10 µL1 - 20 µL2.5 - 50 µL5 - 100 µL10 - 200 µL50 - 1000 µL
0.1 - 2 mL0.25 - 5 mL0.5 - 10 mL
0.5 - 10 µL2.5 - 50 µL10 - 200 µL20 - 350 µL
0.5 - 10 µL2.5 - 50 µL10 - 200 µL20 - 350 µL
0.01 µL0.05 µL0.05 µL0.1 µL0.25 µL0.5 µL1.0 µL5.0 µL
0.01 mL0.05 mL0.05 mL
0.05 µL0.25µL1.0 µL5.0 µL
0.05 µL0.25 µL1.0 µL5.0 µL
<+/- 2.5 % 1)
<+/- 1.2 % 2)
<+/- 1.2 % 2)
<+/- 1.2 % 2)
<+/- 1.0 % 2)
<+/- 1.0 % 2)
<+/- 1.0 % 2)
<+/- 0.8 % 2)
<+/- 1.5 % 2)
<+/- 1.2 % 2)
<+/- 1.0 % 2)
<+/- 3.5 % 2)
<+/- 1.0 % 2)
<+/- 0.9 % 2)
<+/- 1.0 % 2)
<+/- 3.5 % 2)
<+/- 1.0 % 2)
<+/- 0.9 % 2)
<+/- 1.0 % 2)
<+/- 0.9 %<+/- 0.6 %<+/- 0.6 %<+/- 0.5 %<+/- 0.5 %<+/- 0.5 %<+/- 0.4 %<+/- 0.4 %
<+/- 0.5 %<+/- 0.5 %<+/- 0.5 %
<+/- 1.0 %<+/- 0.8 %<+/- 0.6 %<+/- 0.6 %
<+/- 1.0 %<+/- 0.8 %<+/- 0.6 %<+/- 0.6 %
<+/- 1.2 %<+/- 0.8 %<+/- 0.8 %<+/- 0.6 %<+/- 0.6 %<+/- 0.6 %<+/- 0.6 %<+/- 0.5 %
<+/- 1.0 %<+/- 0.8 %<+/- 0.7 %
<+/- 1.5 %<+/- 0.9 %<+/- 0.7 %<+/- 0.8 %
<+/- 1.5 %<+/- 0.9 %<+/- 0.7 %<+/- 0.8 %
Performance values obtained in Forward mode with bi-dist. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655. Performance measured at: 1) 0.5 µL, 2) 10% of nominal volume
* Replace E by country code if other plug type than Europe style needed: G = UK, U = USA-Japan, A = Australia-NZ
< 2.5 % 1)
< 1.5 % 2)
< 1.7 % 2)
< 1.2 % 2)
< 0.7 % 2)
< 0.7 % 2)
< 0.6 % 2)
< 0.4 % 2)
< 0.6 % 2)
< 0.6 % 2)
< 0.5 % 2)
< 3.0 % 2)
< 1.0 % 2)
< 0.6 % 2)
< 0.6 % 2)
< 3.0 % 2)
< 1.0 % 2)
< 0.6 % 2)
< 0.6 % 2)
Ultra 10 µLUltra 10 µL
200 µL200 µL200 µL200 µL200 µL1000 µL
2 mL5 mL10 mL
Ultra 10 µL200 µL200 µL350 µL
Ultra 10 µL200 µL200 µL350 µL
926.0002E926.0010E926.0010YE926.0020E926.0050E926.0100E926.0200E926.1000E
936.02E936.05E936.10E
956.08.010E956.08.050E956.08.200E956.08.350E
956.12.010E956.12.050E956.12.200E956.12.350E
926.0002926.0010926.0010Y926.0020926.0050926.0100926.0200926.1000
936.02936.05936.10
956.08.010956.08.050956.08.200956.08.350
956.12.010956.12.050956.12.200956.12.350
< 0.8 %< 0.35 %< 0.4 %< 0.3 %< 0.25 %< 0.2 %< 0.15 %< 0.1 %
< 0.15 %< 0.15 %< 0.15 %
< 0.7 %< 0.4 %< 0.25 %< 0.25 %
< 0.7 %< 0.4 %< 0.25 %< 0.25 %
< 1.5 %< 0.7 %< 0.8 %< 0.4 %< 0.3 %< 0.3 %< 0.2 %< 0.15 %
< 0.3 %< 0.3 %< 0.2 %
< 0.9 %< 0.6 %< 0.4 %< 0.4 %
< 0.9 %< 0.6 %< 0.4 %< 0.4 %
Volume Division Tip style Cat. No.Initial
package*
Cat. No. Pipette alone
Mid. vol. Max. volMin. vol.Inaccuracy (E%)
Mid. vol.Min. vol.Imprecision (CV%)
Max. vol
Micropipettes Acura® electro 926XS
12-channel pipettes Acura® electro 956
8-channel pipettes Acura® electro 956
Macropipettes Acura® electro 936
6
Ordering information - Volumetric modules and accessories
Performance and ordering information – InstrumentsInitial package includes pipette, charging stand and accessories. Additional pipettes (alone) supplied with individual QC certificate, Qualitips® pipette tips samples and operating instructions.
1.835.6311.835.633
1.831.707
Adapter - 5 mL straw tip
800.12.010800.12.050800.12.200800.12.350
800.0002800.0010800.0010Y800.0020800.0050800.0100800.0200800.1000
Volume range Tip style Cat. No.
0.1 - 2 µL0.5 - 10 µL0.5 - 10 µL1 - 20 µL2.5 - 50 µL5 - 100 µL10 - 200 µL50 - 1000 µL
Ultra 10 µLUltra 10 µL
200 µL200 µL200 µL200 µL200 µL1000 µL
800.0002XS800.0010XS800.0010YXS800.0020XS800.0050XS800.0100XS800.0200XS800.1000XS
Single channel microvolumesReduced shaft length
0.1 - 2 µL0.5 - 10 µL0.5 - 10 µL1 - 20 µL2.5 - 50 µL5 - 100 µL10 - 200 µL50 - 1000 µL
Ultra 10 µLUltra 10 µL
200 µL200 µL200 µL200 µL200 µL1000 µL
Regular shaft length
800.08.010800.08.050800.08.200800.08.350
Volume range Tip style Cat. No.
0.1 - 2 mL0.25 - 5 mL0.5 - 10 mL
2 mL5 mL10 mL
800.2000800.5000800.10000
Single channel macrovolumes
Description Pack Cat. No.
Stand for pipettes or battery packsStand for power handles only
1 / pk1 / pk
320.903.48320.913.48
NiMH, 4.8VNiMH, 4.8V
1 / pk2 / pk
900.920.48900.922.48
Spare battery, blue colour
For 2 and 5 mL modelsFor 10 mL model
250/pk100/pk
322.05322.10
Nozzle protection filters
Europe style plugUK style plugUSA-Japan style plugAustralia - NZ style plug
1 / pk1 / pk1 / pk1 / pk
900.901.48E900.901.48G900.901.48U900.901.48A
Power supply, 100-240V0.5 - 10 µL2.5 - 50 µL10 - 200 µL20 - 350 µL
Ultra 10 µL200 µL200 µL350 µL
8-channel microvolumes
0.5 - 10 µL2.5 - 50 µL10 - 200 µL20 - 350 µL
Ultra 10 µL200 µL200 µL350 µL
12-channel microvolumes
Charging units, 3 positions
For 2 mL modelFor 5 mL model
1 / pk1 / pk
Adapter-nozzle - Pasteur pipette
For 2 and 5 mL models 1 / pkSee Qualitips® page 32 - 34
3
3
3
4
45
52
2
1
1
electronic pipettes & accessoriesAcura®electro
Mid. vol.Volume
Mid. vol. Max. vol. Min. vol.Tip style
Min. vol. Max. vol.Division
< 1.5%< 0.5%< 0.7%< 0.5%< 0.4%< 0.2%< 0.2%< 0.2%
< 3.3%< 1.2%< 1.6%< 1.1%< 0.7%< 0.6%< 0.4%< 0.4%
< 5.0%1)
< 1.8%2)
< 2.5%< 1.7%< 1.0%< 1.0%< 0.6%< 0.5%
< 2.0%< 1.0%< 1.0%< 1.0%< 1.0%< 0.8%< 0.6%< 0.5%
< ± 6.0%1)
< ± 2.5%2)
< ± 2.5%< ± 2.5%< ± 1.5%< ± 1.5%< ± 1.5%< ± 1.5%
< ± 4.0%< ± 1.8%< ± 1.8%< ± 1.8%< ± 1.3%< ± 1.2%< ± 1.1%< ± 1.0%
0.1 – 2 µL 0.5 – 10 µL1 – 10 µL 2 – 20 µL5 – 50 µL10 – 100 µL20 – 200 µL100 – 1000 µL
Ultra 10 µLUltra 10 µL
200 µL200 µL200 µL200 µL200 µL1000 µL
0.002 µL0.01 µL0.01 µL0.02 µL0.1 µL0.1 µL0.2 µL1 µL
Inaccuracy (E%) Imprecision (CV%)
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655. 1) measured at 0.5 µL 2) measured at 1 µL
The Acura® manual 825 / 826 XS
Product advantagesnSmart and reliable volume adjustmentnSingle-handed volume settingnPrecision digital display visible at all timenJustipTM adjustable tip ejector* fitting most tipsnSwift-set user calibration system*nShock, UV-light and autoclaving resistance * Socorex patented
Most comfortable pipettingThe Acura® manual fits everybody’s hand with or without glove. Ergonomic shape, light weight and soft plunger travel care for better comfort.
Ejector button Ergonomically positioned, the large surface, soft padded ejector provides for low-pressure activation.
Adjustable tip ejection Ejector shaft height adjustment system called JustipTM allows a wide selection of tips to tightly fit the nozzle.
Minimum maintenance / sterilisation Easy disassembling for thorough cleaning. Sterilisation achieved by autoclaving instrument fully assembled (121°C / 250°F).
The Acura® manual are precision pipettes combining high-tech materials with exceptional, user friendly ergonomics. There is a choice between 825 model, the classic one for all applications and 826 XS micropipette specially dedicated to research. Both lines bring much more than superior performance and makepipetting safe and agreeable. Three-year warranty.
7
Performance and tip style - Acura® manual 825 and 826 XS micropipettes
5
5
2
2
3
3 4
41
1
825micro
0.1 – 2 µL0.5 – 10 µL1 – 10 µL2 – 20 µL5 – 50 µL10 – 100 µL20 – 200 µL100 – 1000 µL
AN
DE
FR
IT
ESPT
digital reading micropipettesAcura®manual and Acura®manual XS
8
www.socorex.com
Instant calibrationSwift-set user calibration system - with integrated key and locking mechanism - makes tedious procedures a thing of the past. Easy and precise, it is in full compliance with international standards and recommendations.
Safety seal Though easily removed when needed, the switch protection seal is autoclaving resistant. Extra smooth activation
Unique tightness lip seal and new springs provide for ultra-soft pipetting, reducing hand fatigue while working.Above forces, measured on a 20 - 200 µL model, are indicative of very limited finger efforts. Yet, the overshoot stop offers a clear tactile indicator.
* 1 Newton (N) ~ 0.1 kilogramme force (kgf)0.1 - 2 µL0.5 - 10 µL1 - 10 µL2 - 20 µL5 - 50 µL10 - 100 µL20 - 200 µL100 - 1000 µL
Volume weight Cat. No.
88 gr88 gr88 gr88 gr90 gr92 gr90 gr95 gr
84 gr84 gr85 gr85 gr86 gr87 gr86 gr88 gr
825.0002825.0010825.0010Y825.0020825.0050825.0100825.0200825.1000
826.0002826.0010826.0010Y826.0020826.0050826.0100826.0200826.1000
825 826 XS 825 826 XS
Calibration seal stickers
25 / pk100 / pk
1.825.0251.825.100
Replacement sealsReplacement seals
Weights and ordering information - Acura® manual 825 and 826 XS
1 2
1 2 3
3
AN
DE
FR
IT
ESPT
826 XSextra sharp
0.1 – 2 µL0.5 – 10 µL
1 – 10 µL2 – 20 µL5 – 50 µL
10 – 100 µL20 – 200 µL
100 – 1000 µL
extrasharp
The Acura® manual 826 XS
Added advantages, distinct from 825 linenExcellent ergonomic shape and size rationNew springs and tightness seal for extra-smooth activationnReduced weight - lighter than leading brands (see weight chart below)nIncreased driveability with short, narrow shaftnConical shaft end for easy reach in smaller microtubes
Derived from the Acura® manual 825, the 826 XS line was designed with the research scientists in mind. Shorter, smoother, lighter in weight, the eight models offer key features aiming at excellence in pipetting.
Short shaft enhances precision of hand movement and guarantees superior driveability. A great help in fine applications such as pipetting in microtubes or microplates.
See Qualitips® page 32 - 34
9
The Acura® manual 825 / 835 Triopack
nThree adjustable micropipettesnLarge choice of volume combinations up to 10 mLnNine different packs
Pack Cat. No.Contents (Micro /macropipette models)
Pack Cat. No.Contents (Micro /macropipette models)
Pack Cat. No.Contents (Micro /macropipette models)
825.TRIO.C
825.TRIO.J
825.TRIO.M
C
J
M
2 µL(0.1 – 2)
2 µL (0.1 – 2)10Y µL(1 – 10)
10 µL(0.5 – 10)
20 µL(2 – 20)50 µL
(5 – 50)
50 µL(5 – 50)200 µL
(20 – 200)200 µL
(20 – 200)
825.TRIO.O
825.TRIO.P
825.TRIO.S
O
P
S
10 µL(0.5 – 10)10Y µL (1 – 10)20 µL
(2 – 20)
100 µL(10 – 100)
100 µL(10 – 100)200 µL
(20 – 200)
1000 µL(100 – 1000)
1000 µL(100 – 1000)
1000 µL(100 – 1000)
825.TRIO.T
825.TRIO.V
835.TRIO.Y
T
V
Y
50 µL(5 – 50)100 µL (10 – 100)1000 µL(100 – 1000)
200 µL(20 – 200)1000 µL
(100 – 1000)5 mL
(0.5 – 5)
1000 µL(100 – 1000)
5 mL(0.5– 5)10 mL(1 – 10)
Ordering information - TriopackIncluding: sampling of Qualitips®, silicone grease, Q.C. certificates and operating instructions
The Acura® manual 826 TwiXS pack
nTwo adjustable volume pipettesnFree shelf pipette holder (see page 37)nVolume combinations up to 1000 µLnSix different packs
All Acura® pipettes have colour-coded button caps for individual, lab or department identifications. Pick among 14 colours or choose the smartie mix for other colour combinations.
Pack
EGHKNQ
2 µL (0.1 - 2)10 µL (0.5 - 10)20 µL (2 - 20)50 µL (5 - 50)
100 µL (10 - 100)200 µL (20 - 200)
20 µL (2 - 20)100 µL (10 - 100)200 µL (20 - 200)200 µL (20 - 200)
1000 µL (100 - 1000)1000 µL (100 - 1000)
Cat. No.Contents (micropipettes)
826.TWX.E826.TWX.G826.TWX.H826.TWX.K826.TWX.N826.TWX.Q
Cat. No.ColourCat. No.Colour
WhiteGreyVanillaLemonYellowOrangeRed
1.825.7101.825.7151.825.7161.825.7121.825.7171.825.7181.825.714
Assorted colours (14 / pk)
Alternative colour selection (6 / pk)
RosePinkPurpleIce blueBlueMintGreen
1.825.7191.825.7201.825.7211.825.7221.825.7131.825.7231.825.711
1.825.700
Ordering information - TwiXS packIncluding: shelf pipette holder, sampling of Qualitips®, silicone grease, Q.C. certificates and operating instructions
Smartie capsColour coding at will
Pipette packs offer an extended choice of volume combinations, covering all individual requirements in any research or routine application. Available at attractive saver prices, they match with today’s budget constraints.
micropipette saver packs and smartiesAcura®manual
Display always visible Located on the front of the instrument, the display window allows set volume to be visible at all times during pipetting. A comforting reassurance for the user.
10
www.socorex.com
Smart and reliable volume adjustment State-of-the-art micrometric volume setting is performed smoothly and precisely by turning push button. Finely machined click-stops and free rotating cap prevent any unwanted volume alteration.
Mid. vol.Volume
Mid. vol. Max. vol. Min. vol.Tip style Cat. No.
Min. vol. Max. vol.Division
< 0.2%
< 0.3%
< 0.2%
< 0.3%
< 0.5%
< 0.3%
< 0.5%
< 0.6%
< 0.5%
< ± 0.5%
< ± 0.6%
< ± 0.5%
< ± 1.5%
< ± 1.5%
< ± 1.5%
< ± 1.0%
< ± 1.1%
< ± 0.7%
0.2 – 2 mL
0.5 – 5 mL
1 – 10 mL
835.02835.02PP 1)
835.05835.05PP 1)
835.10
2 mL2 mL + Pasteur
5 mL5 mL + Pasteur
10 mL
0.002 mL
0.01 mL
0.01 mL
Inaccuracy (E%) Imprecision (CV%)
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655. 1) Model includes Pasteur adapter nozzle.
Patented tip ejection system Ergonomically positioned, the large surface, soft padded ejector provides for low-pressure activation. In addition, the shaft height adjustment system called JustipTM allows optimal distance setting between ejector and tip.
Pasteur pipette adapter Adapter nozzles allow fitting of Pasteur pipette on Acura® manual 2 and 5 mL models in addition to polypropylene tips. The adapters have two O-rings guaranteeing proper holding and tightness of standard 2 mL Pasteur pipettes (Ø 7 mm).
Nozzle protection filter Protection against liquid overflow and contamination.
Performance and ordering information
The Acura® manual 835
Product advantagesnSmart and reliable volume adjustmentnSingle-handed volume settingnInterchangeable nozzle protection filternJustipTM adjustable tip ejector* fitting most tipsnSwift-set user calibration system*nShock, UV-light and autoclaving resistancenPasteur pipette fitting 2 and 5 mL models * Socorex patented
835macro
0.2 – 2 mL0.5 – 5 mL1 – 10 mL
See consumables page 35 - 36
5 6
6
1
2
Instruments combining high-tech materials with user-friendly ergonomics. Optimal for in- and outdoor environmental analysis, clinical chemistry and cell culture applications, they offer superior performance and make pipetting safer than ever. Three-year warranty.
AN
DE
FR
IT
ESPT
3
3 54
41 2
2 ml5 ml
digital reading macropipettesAcura®manual
The Acura® manual 815 / 835F
Product advantagesnSlim ergonomic design and light weightnSoft plunger activationnJustipTM adjustable tip ejector* fitting most tipsnUser calibration with integrated keynColour coded smartie capnSelection includes macropipette volumes * Socorex patented
Cat. No.Inaccuracy (E%)
Imprecision (CV%)
Tip styleVolume
1 µL5 µL10 µL10Y µL15 µL20 µL25 µL30 µL32 µL40 µL50 µL60 µL70 µL75 µL80 µL90 µL100 µL120 µL
Acura® manual 815 < ± 2.0%< ± 1.4%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.75%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%
< 1.0%< 1.0%< 0.7%< 0.8%< 0.5%< 0.5%< 0.6%< 0.6%< 0.6%< 0.5%< 0.4%< 0.5%< 0.4%< 0.4%< 0.35%< 0.3%< 0.3%< 0.4%
Ultra 10 µLUltra 10 µLUltra 10 µL
200 µL200 µL200 µL200 µL200 µL200 µL200 µL200 µL200 µL200 µL200 µL200 µL200 µL200 µL200 µL
815.0001815.0005815.0010815.0010Y815.0015815.0020815.0025815.0030815.0032815.0040815.0050815.0060815.0070815.0075815.0080815.0090815.0100815.0120
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.
Cat. No.Inaccuracy (E%)
Imprecision (CV%)
Tip styleVolume
150 µL200 µL250 µL300 µL400 µL500 µL600 µL700 µL750 µL800 µL900 µL1000 µL
2 mL2.5 mL5 mL10 mL
Acura® manual 835F
Acura® manual 815 (Continued)
< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.7%< ± 0.6%
< ± 0.8%< ± 0.8%< ± 0.7%< ± 0.5%
< 0.3%< 0.3%< 0.4%< 0.4%< 0.3%< 0.3%< 0.3%< 0.2%< 0.2%< 0.2%< 0.2%< 0.2%
< 0.5%< 0.5%< 0.3%< 0.2%
200 µL200 µL1000 µL1000 µL1000 µL1000 µL1000 µL1000 µL1000 µL1000 µL1000 µL1000 µL
2 mL5 mL5 mL10 mL
815.0150815.0200815.0250815.0300815.0400815.0500815.0600815.0700815.0750815.0800815.0900815.1000
835.F02835.F02.5835.F05835.F10
Performance and ordering information
Tip ejection – easier than everMost ergonomically positioned, the large surface, soft padded ejector button provides for low-pressure activation. In addition to ease of tip ejection, the shaft height adjustment system called JustipTM – controlled by efficient click-stops – allows a wide selection of tips to tightly fit the nozzle.
815 / 835Ffixed
1 µL to 10 mL
11
See Qualitips® page 32 - 34
1 2 3
21
AN
DE
FR
IT
ESPT
Fixed volume micro and macropipettes show the most stable performance. They provide consistent results for any analytical or routine diagnostic tests by eliminating the risk of erroneous volume setting. Three-year warranty.
3
fixed volume pipettesAcura®manual
www.socorex.com
12
Built with the users in mind, these pipettes combine high-tech materials with exceptional, user-friendly ergonomics. They extend pipetting possibilities in 96-well microplates and guarantee outstanding performance and results. Three-year warranty.
The Acura® manual 855
Product advantagesn8- and 12-channel models up to 350 µLnLight weight and perfect hand fittingnPrecision digital display visible at all timenJustipTM adjustable tip ejector* fitting most tipsnSwift-set user calibration system*n360° rotation of volumetric module * Socorex patented
855 models Weight8x 0.5 - 10 µL8x 5 - 50 µL8x 20 - 200 µL8x 40 - 350 µL12x 0.5 - 10 µL12x 5 - 50 µL12x 20 - 200 µL12x 40 - 350 µL
155 gr165 gr165 gr168 gr184 gr199 gr201 gr203 gr 2 31
AN
DE
FR
IT
ESPT
855multi
0.5 – 10 µL5 – 50 µL20 – 200 µL40 – 350 µL
Most comfortable pipetting Ergonomic shape, lightweight and ultra-soft plunger travel are key elements of the Acura® manual pipettes.
Optimal working position Revolving over 360°, the volumetric module (lower assembly) helps reaching the appropriate hand position.
Adjustable tip ejector Position of tip ejector can be adjusted in no time within a 4 mm span to perfectly match with tips used. Bowed shape of ejector head guarantees effort-less, easy sequential tip removal.
Multichannel reservoirs Well adapted for multichannel pipettes, the reagent reservoirs offer various shapes and volumes.
1 2 3
See consumables page 35 - 36
Mid. vol.Volume
Mid. vol. Max. vol. Min. vol.Tip style Cat. No.
Min. vol.
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.1) measured at 1 µL
Max. vol.Division
0.5 – 10 µL5 – 50 µL20 – 200 µL40 – 350 µL
0.5 – 10 µL5 – 50 µL20 – 200 µL40 – 350 µL
0.01 µL0.1 µL0.2 µL0.4 µL
0.01 µL0.1 µL0.2 µL0.4 µL
< ± 3.5%1)
< ± 1.0%< ± 0.9%< ± 1.0%
< ± 3.5%1)
< ± 1.0%< ± 0.9%< ± 1.0%
< ± 2.5%< ± 0.9%< ± 0.8%< ± 0.9%
< ± 2.5%< ± 0.9%< ± 0.8%< ± 0.9%
< ± 1.5% < ± 0.8%< ± 0.7%< ± 0.8%
< ± 1.5%< ± 0.8%< ± 0.7%< ± 0.8%
< 3.0%1)
< 1.0%< 0.6%< 0.6%
< 3.0%1)
< 1.0%< 0.6%< 0.6%
< 1.0%< 0.4%< 0.3%< 0.3%
< 1.0%< 0.4%< 0.3%< 0.3%
< 2.0%< 0.7%< 0.5%< 0.5%
< 2.0%< 0.7%< 0.5%< 0.5%
Ultra 10 µL200 µL200 µL350 µL
Ultra 10 µL200 µL200 µL350 µL
855.08.010855.08.050855.08.200855.08.350
855.12.010855.12.050855.12.200855.12.350
Inaccuracy (E%) Imprecision (CV%)
8-channel
12-channel
Performance and ordering information
multichannel micropipettesAcura®manual
The Acura® manual 810
Product advantagesnTwo pre-calibrated fixed volumes – no setting requirednSmooth activation, excellent ergonomics nInterchangeable PE nozzle protection filter nJustipTM system for height adjustment of tip ejectornIndependent calibration for each volumenEasy maintenance, cleaning and disinfectionnFully autoclavable 121°C / 250°F
Air displacement pipette with two pre-calibrated steps allowssubsequent pipetting of 1 and 0.1 mL of the same liquid. Metal nozzle fits long straw tips to aspirate from narrow or deep reservoirs (i.e. Stomacher® bags). Ideal alternative to the graduated glass pipettes when performing serial 1:10 dilutions in bacteriology. Three-year warranty.
Simple operation Depress plunger button in full, then release slowly to aspirate 1.1 mL Depress plunger button to first stop, thus dispensing 1 mL in Petri dish Depress plunger button to second stop, thus dispensing residual 0.1 mL in next Petri dish
No setting requiredTwo fixed volumes within one plunger travel.
Innovative dual calibrationBoth volumes of 1 mL and 0.1 mL can be calibrated independentlyfrom each other. Calibration switch protected by seal sticker.
Volume Inaccuracy(E%)
Imprecision(CV%)
Cat. No.
810.1100< ± 0.5%< ± 2.0%
< 0.4%< 2.5%
1 mL0.1 mL
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.
Performance and ordering information – Instrument
Description
Straw tips, polypropylene, sterilized (L: 190 mm, Ø:4 mm)
Packaging
40x 25 / pk
Cat. No.
313.1119.40Nozzle protection filter, PE materialWork station 340 for 3 pipettesShelf pipette holder 332 for 2 pipettesShelf pipette holder 332 for 2 pipettes
100 / pk 322.8101 / pk 320.3401 / pk4 / pk
320.332320.332.4
Ordering information – Accessories
JustipTM ejectorTurn left or right to adjust ejector to straw tip position on the nozzle.
Straw tipsFirst class polypropylene. Size 190 mm. Specially designed for narrow vials and Stomacher® bags. Large diameter (4mm) prevents blocking by particles in suspension.
8101 + 0.1 mL
1
2
3
1.1 mL 1.0 mL 0.1 mL
1 2 3
13
2 3 41
1
2
3
4
AN
DE
FR
IT
ESPT
1:10 dilution pipetteAcura®manual
14
The Calibra® digital 822 / 832
Product advantages nWinding-free, instant volume adjustmentnLong term performance and calibration stabilitynRobust, long lasting constructionnShock, UV-light and autoclaving resistancenReliable user calibrationnMinimal maintenance requirementsnInterchangeable nozzle filter in all macro modelsnPasteur pipette adapter (Cat. No. 1.835.631) included with 2 mL model
Mid. vol.Volume
Mid. vol. Max. vol. Min. vol.Tip style Cat. No.
Min. vol.Inaccuracy (E%) Imprecision (CV%)
Max. vol.Division
< 1.5%< 0.5%< 0.7%< 0.5%< 0.2%< 0.2%< 0.2%
< 0.2%< 0.15%
< 3.3%< 1.3%< 1.6%< 1.1%< 0.6%< 0.4%< 0.4%
< 0.3%< 0.3%
< 5.0%1)
< 2.0%< 2.5%< 1.7%< 1.0%< 0.6%< 0.5%
< 0.5%< 0.3%
< ± 2.0%< ± 1.0%< ± 1.0%< ± 1.0%< ± 0.8%< ± 0.6%< ± 0.5%
< ± 0.5%< ± 0.5%
< ± 6.0%1)
< ± 2.5%< ± 2.5%< ± 2.5%< ± 1.5%< ± 1.5%< ± 1.5%
< ± 1.5%< ± 1.5%
< ± 4.0%< ± 1.5%< ± 1.5%< ± 1.5%< ± 0.9%< ± 0.9%< ± 0.6%
< ± 1.0%< ± 1.0%
0.2 – 2 µL1 – 10 µL1 – 10 µL2 – 20 µL10 – 100 µL20 – 200 µL100 – 1000 µL
0.2 – 2 mL 1 – 10 mL
822.0002822.0010822.0010Y822.0020822.0100822.0200822.1000
832.02832.10
Ultra 10 µLUltra 10 µL
200 µL200 µL200 µL200 µL1000 µL
2 mL10 mL
0.1 µL0.05 µL0.05 µL0.1 µL0.5 µL1.0 µL5.0 µL
0.01 mL0.1 mL
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.1) measured at 0.5 µL
Calibra® digital 822
Calibra® digital 832
Performance and ordering information
Instant volume settingTwin cam system fitted with pre-calibrated steps providing for true digital volume entry and numerical display. The dual incrementation allows fast volume setting without tedious winding.
822micro
0.2 – 2 µL1 – 10 µL2 – 20 µL
10 – 100 µL20 – 200 µL
100 – 1000 µL
Key volume adjustmentExample: from 10 to 50 µL in half a revolution of the setting wheel placed in its normal position.
1
1
Fine-tuning adjustmentExample: from 50 to 55.5 µL in half a revolution of the setting wheel in its “pulled” position.
2
2
AN
DE
FR
IT
ESPT
832macro
0.2 – 2 mL1 – 10 mL
The combination of instant volume adjustment, mechanical precision and ease of use makes the Calibra® digital a most reliable and robustmicropipette line in the market. Three-year warranty.
Thin shaft shape helps reach contents from microtubes and/or narrow containers. The Calibra® provides convenient access into those hard to reach places.
digital setting micro and macropipettes
Calibra®digital
www.socorex.com
15
The Calibra® digital 852
Product advantages nWinding-free, instant volume adjustmentnLong term performance and calibration stabilitynLower assembly rotates 360° for optimal working comfortnEasy sequential tip ejectionnCalibration simple to perform by usernShock, UV-light and autoclaving resistance
Easy in-lab calibrationThe calibration screw is located under the rubber pad. Engraved graduations help calibrate instrument quickly and precisely. Calibration key supplied with the instrument.
Multichannel reservoirsWell adapted for multichannel pipettes, the reagent reservoirs come in various shapes and volumes. See page 36.
360° rotationIn addition to ergonomic hand fitting, the pipette lower assembly revolvesfor added user comfort.
Sequential tip ejectionSpecial shape of ejector head guarantees effortless, sequential easy tip ejection.
VolumeMax. vol. Min. vol.
Cat. No.Min. vol. Max. vol.
Division
0.05 µL0.5 µL1.0 µL
0.5 µL1.0 µL
1 – 10 µL10 – 100 µL20 – 200 µL
10 – 100 µL20 – 200 µL
< ± 3.5%< ± 1.0%< ± 0.9%
< ± 1.0%< ± 0.9%
< ± 2.5%< ± 0.9%< ± 0.9%
< ± 0.9%< ± 0.9%
< ± 1.5%< ± 0.7%< ± 0.7%
< ± 0.7%< ± 0.7%
< 3.0%< 1.0%< 0.6%
< 1.0%< 0.6%
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.
< 1.0%< 0.4%< 0.3%
< 0.4%< 0.3%
< 2.0%< 0.7%< 0.4%
< 0.7%< 0.4%
852.08.010852.08.100852.08.200
852.12.100852.12.200
Mid. vol.Mid. vol.Inaccuracy (E%) Imprecision (CV%)
8-channel
12-channel
Performance and ordering information
852multi
1 – 10 µL10 – 100 µL20 – 200 µL
See pipette stands page 37 - 38
3
3 5
4
41 2 5 6
1 2
AN
DE
FR
IT
ESPT
8- and 12-channel micropipettes with winding-free, instant volume adjustment extend pipetting possibilities in microplates. Three-year warranty.
See Qualitips® page 32 - 34 6
digital setting multichannel pipettesCalibra®digital
www.socorex.com
High performance positive displacement micropipettes with interchangeable glass capillary tube and ETFE tipped plunger. The soft shaped handle and smooth plunger activation provides for enhanced hand comfort while handling viscous liquids, foaming solutions or volatile solvents. Five models cover a range from 1 to 200 µL. Three-year warranty.
The Acura® capillar 846
Product advantages nSlim body shape, comfortable finger restnSmooth plunger activationnReliable, step-wise volume adjustmentnColour codes matching on pipettes, plungers and capillariesnStainless steel, ETFE tipped plunger
Pre-set volumes Each pipette has five, easy to adjust pre-set volumes. Clear volume reading on pipette barrel.
Colour coding Pipette, plunger tip and glass capillary bear colour coding for easy volume identification.
ETFE tipped plunger Chemically inert ETFE material offers excellent resistance when coming in direct contact with liquids.
Workstation 340 For up to three pipettes, any Socorex models. (Cat. No. 320.340).
Enhanced pipetting comfort Instrument slim shape fits any hand. Comfortable hook enables pipette to rest naturally on finger. Well engineered spring system reduces plunger force requirement.
Min. vol.Volumes
Min. vol. Mid. vol. Max. vol. Max. vol.Cat. No.
< 2.5%< 1.0%< 0.8%< 0.6%< 0.3%
< 2.0%< 0.9%< 0.7%< 0.5%< 0.3%
< ± 2.0%< ± 0.8%< ± 0.7%< ± 0.7%< ± 0.7%
< ± 3.0%< ± 1.5%< ± 1.2%< ± 0.7%< ± 0.7%
< ± 2.3%< ± 1.2%< ± 1.0%< ± 0.7%< ± 0.7%
1-2-3-4-5 µL5-10-15-20-25 µL10-20-30-40-50 µL60-75-80-90-100 µL100-120-150-175-200 µL
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655. Model 846 not autoclavable.
Mid. vol.
846.005846.025846.050846.100846.200
< 1.2%< 0.6%< 0.4%< 0.3%< 0.3%
Inaccuracy (E%) Imprecision (CV%)
Colour code
White2x whiteGreenBlueRed
Packaging
200 / pk200 / pk200 / pk200 / pk100 / pk
Cat. No.
341.005341.025341.050341.100341.200
Spare glass capillaries
Colour code
SteelWhiteGreenBlueRed
Packaging
5 / pk5 / pk5 / pk5 / pk5 / pk
Cat. No.
342.005342.025342.050342.100342.200
Spare plungers
Performance and ordering information - Instruments
Ordering information – Accessories
8461 – 5 µL
5 – 25 µL10 – 50 µL
60 – 100 µL100 – 200 µL
1
2
1
3
4
5
2 3 4 5
AN
DE
FR
IT
ESPT
positive displacementmicropipettes
Acura®capillar
16
repeater pipetteStepper™
17
The StepperTM 411
Product advantages n4-finger activationnSetting knobs bear clear indication of volumes and number of aliquots nThree positive displacement syringes, colour coded nSelf-locking mechanism nEcostepTM sterilized syringes in bioproof version
Clear setting indicationAfter inserting disposable syringe, select appropriate volume. Markings on interchangeable selector buttonsallow direct reading of set volume and corresponding number of aliquots.
Ecostep bioproof TM
Single wrapped sterilized high purity grade syringes. Each batch is tested by independent laboratories for sterility, and certified free of detectable DNase, RNase, human DNA and Pyrogen.
Highly comfortable pipette intended for reliable repeat dispensing within 10 to 5000 µL. Unique trigger action mechanism eliminates thumb fatigue. Selected materials offer outstanding shock resistance. Compact shape greatly limits internal instrument contamination. Large selection among53 different volumes; up to 73 doses per filling. Two-year warranty.
41110 – 5000 µL
7349362924201815141211109887776
No. ofaliquots
VolumeµL
VolumeµL
VolumeµL
101520253035404550556065707580859095100
5075100125150175200225250275300325350375400425450475500
50075010001250150017502000225025002750300032503500375040004250450047505000
Fingertip activationUser friendly 4-finger trigger action eliminates thumb fatigue during repeat dosing. Self-locking mechanism prevents false delivery if liquid for the desired dose is insufficient.
Description
StepperTM 411 incl. 3 colour coded selector buttons, adapter, EcostepTM syringe samplesReplacement adapter for red EcostepTM syringeStand for one Stepper
Packaging
1 / pk
5 / pk
1 / pk
411.5000
1.411.7
320.411
Cat. No.
Ordering information
Volume Syringecapacity
Performanceat
Inaccuracy(E%)
Imprecision(CV%)
Sterilized & bioproof
Packaging Cat. No.
20 µL100 µL100 µL500 µL1000 µL5000 µL
< ± 1.5%< ± 1.0%< ± 1.0%< ± 0.5%< ± 0.8%< ± 0.5%
< 1.5%< 0.8%< 1.0%< 0.5%< 1.2%< 0.4%
noyesnoyesnoyes
100 / box100 x 1 / box
100 / box100 x 1 / box
100 / box100 x 1 / box
316.010316.010.9316.050
316.050.9316.500
316.500.9
0.75 mL
3.75 mL
37.5 mL
10 – 100 µL
50 – 500 µL
500 – 5000 µL
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°Cin accordance with method described in EN ISO 8655.
Performance and ordering information – EcostepTM syringesNon sterile syringes are supplied in bulk. Sterilized, single wrapped bioproof version with high biological purity grade, each batch is human DNA, DNase, RNase and Pyrogen (endotoxin) free certified.
STOP
1
1 2
2 3 4
4
3
AN
DE
FR
IT
ESPT
www.socorex.com
The Acura® manual 865
Product advantages nExcellent ergonomics, soft plunger activationnLarge volume displaynEasy in-lab calibrationnNo need for consumablesnAutoclavable fully assembled at 121°C / 250°FnVersatile feeding through bottle, tubing or syringe
Description Packaging Cat. No.
1 / pk1 / pk1 / pk1 / pk
1 / pk1 / pk1 / pk
1 / pk
1 / pk
1.861.6311.861.21T1.861.9251.861.720
1.861.5691.861.E321.170.054
1.170.058
320.340
Reservoir*, 30 mL, PP, LuerReservoir*, 30 mL, PTFE, LuerVial holder*, LuerInlet valve cap*, female Luer(for syringe)Outlet valve cap*, Luer LockPTFE delivery cannula*Manifold*, 4-channel, Luer Lock,stainless steel (9mm spacing)Manifold*, 8-channel, Luer Lock,stainless steel (20mm spacing)Work station 340 for 3 pipettes*Autoclavable
Ordering information – Accessories
Hand-held, self-refilling microdispenser intended for repeat distribution of microliter volumes. Carefully selected materials ensure durability and resistance to aggressive media. Instrument combines easy handling of a regular micropipettewith flexibility of a repeater pipette. There is no need for plastic tips or consumables, which may represent substantial savings.Three-year warranty.
Convenient dispensingReliable valve system ensures highperformance dispensing, dose after dose. It revolves to allow selection of the best working position.
Min. vol.Volume
Min. vol. Mid. vol. Max. vol.Division
Max. vol.Cat. No.
< 2.0%< 1.5%< 0.6%
< 1.4%< 1.0%< 0.4%
< ± 1.5%< ± 1.0%< ± 0.6%
< ± 5.0%< ± 2.5%< ± 1.5%
< ± 3.5%< ± 1.8%< ± 1.1%
5-50 µL20-200 µL100-1000 µL
0.1 µL0.2 µL1.0 µL
Mid. vol.
865.0050865.0200865.1000
< 0.4%< 0.3%< 0.2%
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655. Values altered using manifold.
Inaccuracy (E%) Imprecision (CV%)
Performance and ordering information – InstrumentsIncluding: 90 cm silicone tubing, SS blunt end cannula, female Luer inlet valve cap,Q.C. certificate and operating instructions.
Swift-set calibration system* Easy and precise system with integrated key and locking mechanism, making tedious procedures a thing of the past.
* Socorex patented
Protective calibration seal sticker
Choice of feeding sourcesSupplied with 90 cm silicone tubing, the instrument also fits optional feeding sources: bottle, vial, syringe.
Great distribution flexibilityOutlet nozzle fits any Luer Lock needles and cannulas. Optional PTFE cannula provides enhanced chemical resistance. Use 4- or 8-channel manifold whendispensing into microplates.
18655 – 50 µL
20 – 200 µL100 – 1000 µL
2
3
1 2 3
Chemical compatibility see page 25Needles and cannulas see page 28
Excellent ergonomics Instrument shape and lightweight offer most convenient pipetting comfort. Smooth plunger activation drastically reduces hand fatigue.
1
1
2 3 4
2 3 4
Socorexcalibration
seal
AN
DE
FR
IT
ESPT
self-refillingmicrodispenser pipette
Acura®manual
18
The AcurexTM compact 501
Product advantages nIntegrated dosing mechanismnSimple, robust construction nRetractable graduated column reduces instrument height nFluid path materials excluding any metalnChoice of four reservoir sizesnFully autoclavable at 121°C / 250°F
Autoclavable extension tubingPTFE Jet-PenTM and tubing help dispense into vessels with maximum comfort within a 60 cm distance. For 1 and 2 L reservoirs (Cat. No. 1.523).
Compact dispensers for safe reagent handling, adapted to refrigerator storage as well as water bath heating. Dosing mechanism entirely protected inside reservoir. Manufactured and tested to fully comply with the latest regulations on instrument safety and precision. Volumes range from 0.2 to 30 mL. Two-year warranty.
Valve
BarrelPlungerReservoirDelivery jet and union
Pyrex glass and synthetic rubyNeutral glassPTFE-coated glassAmber glassPVDF / FEP / PFA
MaterialsParts
Volume Division
Min. vol. Mid. vol.
Imprecision (CV%)
Max. vol.
< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%< 0.1%
< 0.5%< 0.5%< 0.5%
< 0.5%1)
< 0.5%1)
< 0.5%1)
< 0.5%< 0.5%
< 0.5%2)
< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%< 0.35%
0.1 mL0.1 mL0.1 mL0.2 mL0.2 mL0.2 mL0.2 mL0.2 mL1.0 mL
Reservoircapacity
250 mL1000 mL2000 mL500 mL1000 mL2000 mL1000 mL2000 mL2000 mL
Cat. No.
501.02025501.021501.022501.0505501.051501.052501.101501.102501.302
0.2 – 2 mL0.2 – 2 mL0.2 – 2 mL0.4 – 5 mL0.4 – 5 mL0.4 – 5 mL1 – 10 mL1 – 10 mL1 – 30 mL
Performance values obtained with bidest. water at constant temperature (± 0.5°C) comprised between20 and 25°C in accordance with ISO 8655. 1) measured at 0.5 mL 2) measured at 3 mL
Performance and ordering information
Space saving low profileThe graduated column is retractable for height reduction, making the dispenser ideal for storage in refrigerators.
Chemically inert materialsAll parts in contact with the liquid are made from chemically inert materials:
Glass reservoirAmber glass offers optimal light protection.
5010.2 – 2 mL0.4 – 5 mL1 – 10 mL1 – 30 mL
Chemical compatibilitysee page 25
1
1 2 3 4
2 3 4
AN
DE
FR
IT
ESPT
low-profile dispensersAcurex™compact
19
www.socorex.com
20
The CalibrexTM 520
Product advantagesnSuperior chemical resistancenLong-lasting performance stability nSimple construction – no tool for disassembling nInstant volume settingnIn-lab calibrationnAutoclavable at 121°C / 250°F fully assembled
Designed for performance handling of liquids from a large variety of bottles and flasks, the Calibrex™ dispenser combine the latest in dosing technology, high-tech materials and ergonomic design. They are manufactured and tested to fully comply with current safety regulations. Fixed versions also available in any volume within these ranges. Two-year warranty.
Large display is easy to read; the window adjusts to desired side of instrument body. Each step on the cylindrical cam is pre-calibrated and corresponds to one division on the volume adjustment scale.
Friendly digital volume settingFast and precise volume adjustment. Efficient click-stop mechanism prevents unwanted alteration.
Air filter Air inlet can be enlarged to receive a membrane filter, if airborne contamination is a concern.
Easy maintenance Disassembling / reassembling is facilitated by the limited number of well-connected parts - no tool needed.
Superior material selection Special attention is paid to component materials, providing for long instrument life. Parts coming in contact with the liquid flow are chemically inert.
5200.25 – 2 mL
1 – 5 mL1 – 10 mL
1
1 3
4
5
6
2
2
3 4 5 6
AN
DE
FR
IT
ESPT
bottle-top dispensersCalibrex™digital
Min vol.Volume Division
Min. vol. Mid. vol. Max. vol.
< 0.5%< 0.5%< 0.5%
Mid. vol. Max. vol.
< 0.1%< 0.1%< 0.1%
< ± 0.6%< ± 0.6%< ± 0.6%
< ± 3.0%< ± 2.0%< ± 1.5%
< ± 1.8%< ± 1.3%< ± 1.1%
< 0.35%< 0.35%< 0.35%
0.05 mL0.1 mL0.25 mL
0.25 – 2 mL1 – 5 mL1 – 10 mL
Cat. No.Adj.
volume520.002520.005520.010
Cat. No.Fixed
volume*520.F02520.F05520.F10
Inaccuracy (E%) Imprecision (CV%)
* Specify desired fixed volume within instrument range when ordering. Performance values obtained with bidist. water at constant temperature (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.
Performance and ordering informationCalibrex™ have a 32 mm base thread. They come with three adapters: 28, 40, 45 mm and feed tube 300 mm.
Parts Materials
Feed tubeIntake valveValve ballsValve springBarrelBarrel plate / basePlungerOutlet valveBodyDelivery jet assembly
PTFECeramicPyrex glassPlatinum-iridiumBorosilicate glassPTFEGlass with PFA coatingCeramicETFEPTFE/ETFE
Large selection of bottlessee page 24
In-lab calibration CalibrexTM dispensers are factory cali-brated and can be easily recalibrated by means of a dedicated adjustment screw.
Optimised working position The instrument rotates 360° for adequate positioning on top of the bottle.
21
bottle-top dispensersCalibrex™
a
c
b
1 3 52 4 6
The CalibrexTM 525 / 530
Product advantagesnSelection between two different modelsnPermanent fluid path visibilitynIntegrated calibration systemnChoice of adjustment button with each unitnFlow control system with stopcock (optional)nQR code accessing compatibility chartnAutoclavable at 121°C / 250°F fully assembled
The new generation of robust instruments with excellentchemical resistance, high performance and easy maintenance. Fitting most reagent bottles, it enables safe and reproducible dispensing within volumes up to 25, 50 and 100 mL. Choose between the organo and the solutae models foradequate resistance to liquid dispensed. Two-year warranty
525 / 5302.5 – 25 mL
5 – 50 mL10 – 100 mL
AN
DE
FR
IT
ESPT
Ease of useSmooth aspiration and distribution for trouble-free routine dispensing. Dual scale enables volume reading from a wide angle.
Choice of setting buttons Sliding cursor softly moves up and down scale and precisely stops at desired graduation. Installed on each unit. Alternative classical screwbutton supplied with each dispenser as an accessory. Easy to exchange by user.
Permanent visibility Safety transparent thick sleeve around barrel and delivery jet window allow liquid flow monitoring.
Optimal working position The instrument rotates 360° for adequate positioning on the bottle. Free rotating dispenser body makes volume clearly visible from any position.
Flow control stopcockNext to its dispensing position (b), device enables liquid priming and recycling (a) without reagent loss or contamination. Locking position (c) for safe dispenser transportation.
1
3
4
5
62
www.socorex.com
22
bottle-top dispensersCalibrex™
1
1
3
5
42
2
3 5
Chemical compatibility see page 25
Easy In-lab calibration Access to mechanism protected by safety seal sticker. Integrated key located under plunger cap. Engraved +/- arrows for easy and precise setting.
Performance and ordering information - CalibrexTM 525 and 530 Supplied with 45 mm base thread, 120 mm delivery jet and stopper, 350 mm feed tube, alternative screw-type volume setting button, three bottle neck adapters (32, 38 and 40 mm), QC certificate and operating instructions. All models available with and without stopcock.
MaintenanceDisassembling/reassembling facilitated by limited number of parts – no tool needed. Key elements such as valves, plunger, barrel and delivery jet removable in seconds for cleaning. Fully autoclavable at 121°C / 250°F.
Model differentiation
Material selectionParts in contact with liquid flow are chemically inert, providing for stability and long instrument life.
Chemical resistance Printed QR code for instant access to chemical resistance chart.
Air filter Air inlet can be enlarged to receive a membrane filter, if airborne contamination is a concern.
Parts 525 organo 530 solutae
FEPCeramicCeramic
Platinum-iridiumPTFE
Borosilicate glass Ground glass PFA coated glass
ETFEFEP / PCTFE
ETFE
Feed tubingValve bodyValve ballsValve springValve plateBarrelPlungerConnecting bodyDelivery jetStopper
* Except hydrofluoric acids (HF)
organo solutaeOrganics Non-crystallizing sol. Inert reagents Salt solutions Strong acids* & bases
FEP feed tubing
Air inlet for filter connection
Calibration safety seal sticker Colour coding by model
Screw-type volume adjustment button (interchangeable, as alternative supplied with all models)
PFA coated plunger
Transparent safety sleeve
Flow control stopcock
Integrated calibration key under cap
Dual graduation
Volume adjustment sliding cursor (pre-mounted)
Ground glass plunger
Disassemblingnut, no toolneeded
Screw-lockingstopper Liquid viewing window
360° rotation on bottle 4
2.5–255–5010–100
0.51.01.0
< ± 1.5%< ± 1.5%< ± 1.5%
< ± 1.1%< ± 1.1%< ± 1.1%
RangemL
DivisionmL Min.vol Mid.vol Max.vol Min.vol Mid.vol Max.vol Regular (no stopcock) With stopcock Regular (no stopcock) With stopcock
Imprecision (CV%) Calibrex™ organo 525 Calibrex™ solutae 530Inaccuracy (E%)
< ± 0.6%< ± 0.6%< ± 0.6%
< 0.5%< 0.5%< 0.5%
< 0.35%< 0.35%< 0.35%
< 0.1%< 0.1%< 0.1%
525.025525.050525.100
525.025FC525.050FC525.100FC
530.025530.050530.100
530.025FC530.050FC530.100FC
2.5–255–5010–100
0.51.01.0
< ± 1.5%< ± 1.5%< ± 1.5%
< ± 1.1%< ± 1.1%< ± 1.1%
< ± 0.6%< ± 0.6%< ± 0.6%
< 0.5%< 0.5%< 0.5%
< 0.35%< 0.35%< 0.35%
< 0.1%< 0.1%< 0.1%
525.F025525.F050525.F100
525.F025FC525.F050FC525.F100FC
530.F025530.F050530.F100
530.F025FC530.F050FC530.F100FC
Performance values obtained by a smooth and steady pace movement, with bidest. water at constant temperature (± 0.5°C) comprised between 20 and 25°C, according to EN ISO 8655.Warning: omission to untighten connecting body ring before autoclaving, and / or over-tightening ring when dispensing, may reduce performance.
Adjustable volume models
Fixed volume models (specify desired fixed volume within dispenser range)
Flow control stopcockDevice compatible with any CalibrexTM 525 / 530. Enables liquid priming and recycling without reagent loss or contamination. No tool needed to assemble or to remove for cleaning. Fully autoclavable.
Extension tubing kit(workstation not included)
Workstation for small bottle Workstation and feed tubingfor remote aspiration
Delivery jetStandard (120 mm) and extended (150 mm) assemblies are exchangeable without any tool. Fully autoclavable.
Extension tubingTubing and delivery Jet-PenTM, helpdispense into vessels with maximum comfort within a 60 cm distance. No tool needed to assemble or to remove for cleaning. Fully autoclavable.
Description Pack Cat. No.
320.SB050320.SB100
320.BC050320.BC1001.525.581
1 / pk1 / pk
1 / pk1 / pk1 / pk
* Dispenser and feed tubing / connector to be ordered separately
Work station for dispenser stabilityFits Calibrex™ 520 dispenserFits Calibrex™ 525/530 dispensersRemote aspiration work station and feed tubingWork station for Calibrex™ 520 disp.*Work station for Calibrex™ 525/530 disp.*Feed tubing with connectorfor Calibrex™ 525/530
Description Pack Cat. No.
1.525.546
1.525.1201.525.121
1.525.1501.525.151
1 / pk
1 / pk1 / pk
1 / pk1 / pk
Flow control stopcock, fits Calibrex™ 525 / 530
For 25, 50 and 100 mL modelsDelivery jet assembly, 120 mm, fits Calibrex™ 525/530
For 25 mL dispenserFor 50, 100 mL dispensersDelivery jet assembly, extended, 150 mm, fits Calibrex™ 525/530
For 25 mL dispenserFor 50, 100 mL dispensers
Description L./Mat. Cat. No.
1.524
1.525.625
1.525.650
int. Ø
2.2 mm
4 mm
4 mm
600 mmPTFE
600 mmFEP/PCTFE600 mm
FEP/PCTFE
Extension tubing and Jet-Pen™
Fits Calibrex™ 520/521up to 20 mLFits Calibrex™ 525/530up to 25 mLFits Calibrex™ 525/53050 and 100 mL
Dispenser stability Stand holds dispenser when screwed on small-size bottle.Remote aspiration Work station facilitates liquid intake from drum or other remote container (< 10 m distance, < 2 m elevation).
accessoriesCalibrex™digital
23
4
5
543
1
1 2
2
3
3
60 cm
1
CalibrexTM 520 have a 32 mm base thread. They come along with threePP material bottle neck adapters in 28, 40 and 45 mm diameters. For other bottle neck diameters, simply orderthe appropriate adapter size.
Bottle-neck adapters CalibrexTM 525/530 have a 45 mm base thread. They come along with three PP material bottle neck adapters in 32, 38 and 40 mm diameters. For other bottle neck diameters, use 32 mm adapter (cat. No. 1.525.GL32) nested with any CalibrexTM 520 adapters.
Calibration seal stickers Autoclavable seal sticker protects access to the calibration mechanismof CalibrexTM 525/530 models.
Replacement tubing Feed tubing available either cutto the standard size, or uncutby the meter.
Description Length Cat. No.
525.350525.706
511.707521.621521.622521.623511.709
521.705
521.706
int. Ø
7 mm7 mm
5 mm
7.5 mm10 mm10 mm 5 mm
7.5 mm
10 mm
350 mmspecify
300 mm300 mm300 mm375 mmspecify
specify
specify
Feed tubing, FEP, for Calibrex™ 525/530For all sizes, cutFor all sizes, by themeter, uncutFeed tubing, PTFE, for Calibrex™ 520/521For 520 all sizes, cutFor 521, 20 mL, cutFor 521, 50 mL, cutFor 521, 100 mL, cutFor 520 all sizes, by the meter, uncutFor 521, 20 mL, by the meter, uncutFor 521, 50 and 100 mL,by the meter, uncut
Type Ext. Ø of bottle neck Cat. No.
1.525.GL321.525.GL381.525.GL40
GLP + ØGLT + ØNSP + ØNST + Ø
32 mm38 mm40 mm
22, 25, 28, 30, 34, 36, 38, 40, 45 mm
36, 38, 40, 45 mm18.8, 24, 29.2, 45 mm
18.8, 24, 29.2 mm
Adapters for Calibrex™ 525/ 530
Threaded, PPThreaded, PPThreaded, PPAdapters for Calibrex™ 520 / 521
Threaded, PPThreaded, PTFETapered, PPTapered, PTFE
Description Pack Cat. No.
1.525.5251.525.526
25 / pk100 / pk
Safety seal stickerSafety seal sticker
www.socorex.com
24
Neck,ext. ø
Cat. No.
32 mm32 mm32 mm45 mm45 mm
45 mm
32 mm45 mm45 mm
Volume
100 mL250 mL500 mL1000 mL2500 mL
2500 mL
500 mL1000 mL2500 mL
SquareSquareSquareSquareRound
Round
SquareSquareRound
314.0100314.0250314.0500314.1000314.2500
314.2500H
314.0500PE314.1000PE314.2500PE
Shape
Amber glass1)
Amber glass, with handle1)
PE-coated Amber glass2)
Neck,ext. ø
Cat. No.
45 mm45 mm45 mm45 mm
32 mm
25 mm25 mm32 mm45 mm
Volume
250 mL500 mL1000 mL2000 mL
500 mL
250 mL500 mL1000 mL2500 mL
RoundRoundRoundRound
Round
SquareSquareSquareSquare
314.0250C314.0500C314.1000C314.2000C
314.0500P
315.0250315.0500315.1000315.2500
Shape
Clear Borosilicate glass1)
Clear Pyrex glass, with connection neck1)
Polyethylene2)
45 mm45 mm45 mm45 mm
32 mm
25 mm25 mm32 mm45 mm
250 mL500 mL1000 mL2000 mL
500 mL
250 mL500 mL1000 mL2500 mL
RoundRoundRoundRound
Round
SquareSquareSquareSquare
314.0250C314.0500C314.1000C314.2000C
314.0500P
315.0250315.0500315.1000315.2500
Clear Borosilicate glass1)
Clear Pyrex glass, with connection neck1)
Polyethylene2)
1) autoclavable, 2) not autoclavable
Reagent bottlesLarge selection of glass and polyethylene reagent bottles, each supplied with one PP screw cap. Perfectly adapted with all bottle top dispensers. Corresponding neck adapters supplied with the dispensers.
1
42
2 3
3
4
5
5
25
chemical resistance chartMicrodispenser and dispenser
Technical risks1 = Possible crystallisation, valve or plunger blockage. Scratches on plunger coating if plunger/barrel dried and stick together.2 = Swell of plunger coating, possible peeling. Acura® 865: chemical degradation of O-ring.3 = Release of acid vapours (risk increases with concentration). Do not leave dispenser on bottle. Acura® 865: limited dosing cycles, possible plunger blockage and/or corrosion.4 = Damage, softening or discoloration of external parts through vapours. Do not leave dispenser on bottle. Acura® 865: vapours may damage internal and external parts of upper assembly.5 = Chemical degradation of glass parts (plunger/barrel).
Compatibility statementA = Good resistance B = Acceptable with limitations C = Not recommended
Acura865
Acurex501
AB/2
B/2/4B/4B/4A
B/4AAAA
B/4A
C/2/4A
B/4B/4B/4A
B/1B/4B/4
B/2/4B/4B/4B/4B/4
B/3/4B/3/4
AC/1B/4B/4B/4AAAA
B/4B/4B/4A
B/4B/4AAAAAA
B/4AAAA
B/3C/5B/2
Acetaldehyde (Ethanal)Acetic acid 96%Acetic acid 100% (Glacial)Acetone (Propanone)Acetonitrile (MECN)Amino acidsAmmonium hydroxide (amonia)Amyl alcohol (Pentanol)AnilineAscorbic acidBenzaldehydeBenzeneBoric acid 10%BromineButanolButanone (MEK)Butyl acetateN-ButylamineCalcium chlorideCalcium hydroxideCarbon disulfideCarbon tetrachlorideChlorine dioxideChlorobenzeneChlorobutaneChloroethanolChloroformChlorosulfuric acid 100%Chromic acid 100%Citric acidCyanoacrylateCyclohexaneCyclohexanone1,4-Dioxane (Diethylene dioxide)DichlorobenzeneDichloroethane (DCE)Diesel oil (Heating oil)Diethylene glycolDiethyletherDimethyl sulfoxide (DMSO)Dimethylformamide (DMF)EthanolEtherEthyl acetateEthylenediamineEthylene glycolFormaldehyde (Formalin)FormamideFormic acidGamma-butyrolactoneGasolineGlycerin <40%HeptaneHexaneHydrochloric acid 20%Hydrochloric acid 37% (HCI)Hydrofluoric acid (HF)Hydrogen peroxide
Chemicals A - H Calibrex520 525 530
AA
B/4B/4B/4C/1B/4AA
C/1A
B/4B/1C/4A
B/4B/4B/4C/1C/1B/4B/4B/4B/4B/4B/4B/4
B/3/4B/3/4B/1C/1B/4B/4B/4AAAA
B/4B/1/4B/4A
B/4B/4AAAAAA
B/4AAAA
B/3C/5A
AAA
B/4AAAAAAA
B/4A
B/2A
B/4A
B/4A
B/1AA
B/2/4AAA
B/4B/3B/3A
C/1AAAA
B/4AAAA
B/4A
B/4AAAAAAAAAAAAA
C/5A
AAAAAAAAAAAAA
B/2AAA
B/4B/1B/1AA
B/2/4AAAA
B/2/3B/2/3
AC/1AAAA
B/4AAAAAAAAAAAAAAAAAA
B/2/3B/2/3C/5A
C/2B/2
B/2/3C/2/3B/2
B/1/4C/2A
B/2B/1C/2C/3
B/1/4B/2/3B/2/3C/2C/2
C/2/4B/1/4B/1/4
B/2/3/4C/3
C/2/4B/2B/4B/2
C/2/4C/4B/4A/1
C/1/2/4B/2/3C/2C/2B/4B/4B/3B/4C/2
B/1/2/4C/2/4B/2/4C/2/3
C/2/3/4C/2B/4A
B/2/4C/2/4C/2/4C/3A
B/3B/3C/4C/4
C/2/4B/3/4
Acura865
Acurex501
Chemicals I - Z Calibrex520 525 530
B/1C/2/4
AA
B/4AAA
B/4B/4A
B/2/4C/2/3/4
B/4B/2/4
AAAA
B/4B/4A
B/4B/4A
B/4B/4A
B/4AA
B/1AA
B/1AA
B/4B/4AAAAA
B/4A
B/2/3/4B/2/4B/4
B/2/4B/4B/4B/4B/4B/4A
B/4B/2/4
C/1C/4AA
B/4C/1AA
B/4B/4A
B/4C/3/4B/4B/4AAAA
B/4B/4C/1B/4B/4A
B/4B/4A
B/1/4A
C/1C/1C/1C/1C/1AA
B/4B/4A
C/1C/1C/1C/1C/1C/1
B/3/4B/4B/4B/4B/4B/4
B/1/4B/4B/4A
B/4B/4
AC/2/4
AAAAAAAA
B/4B/2/4B/3A
B/3AAAAAAA
B/4B/3AAAAAAAA
B/1AAAAA
B/4A
B/1AA
B/1AA
B/2/3B/2B/4
B/2/4B/4B/4A
B/4B/4A
B/3B/4
AC/2/4
AAAAAAAA
B/4A
B/2/3A
B/2/3AAAAAAA
B/4B/2/3
AAAAAA
B/1A
B/1AAAAA
B/4AAA
B/1B/1AA
B/2/3B/2/3B/4
B/2/4A
B/4A
B/4AA
B/3A
B/1/2/3/4C/2/4B/3A
B/2/4C/1/4B/2/4C/2/4C/3/4C/2/4
C/2/3/4C/3/4B/2/4B/2/4C/4B/4B/3AA
B/2B/2
B/1/4B/3/4B/4B/4B/3C/3
B/2/3/4B/1/4B/3/4C/1/4B/1/2B/1/2B/1/4
C/1/2/4B/4A
B/2/4C/2/4
---C/1
C/1/2B/1/4C/1/2
C/1/2/4B/1/4B/2/4B/3/4B/2/4C/2/4
C/2/3/4C/3
C/1/2/4C/3
B/2/4B/2/4B/2/4
C/2/3/4
IodineIodine bromide / chlorideIsooctaneIsopropanolIsopropylamineLactic acid2-MethoxyethanolMethanolMethyl chloride (Chloromethane)Methyl methacrylate (MMA)Methyl propyl ketone (2-Pentanone)Methylene chloride (Dichloromethane) (DCM)Nitric acid 100%Nitric acid dil. <30%Nitro-hydrochloric acid (Aqua regia)N-methyl-2-pyrrolidone (NMP)OctaneOctanolOil, mineral (engine oil)Oil, vegetable, animalOil of turpentineOxalic acidPentanePerchloric acid 100%Perchloric acid dilutedPetroleumPetroleum ether / spiritPhenolPhenylhydrazinePhosphoric acid 85%Potassium chloridePotassium dichromatePotassium hydroxidePotassium iodidePotassium permanganatePropionic acid (Propanoic acid)Propylene glycol (Propane-1,2-diol)Picric acid (Trinitrophenol)PyridineScintilation fluidSilver nitrateSodium acetateSodium chloride (Kitchen salt)Sodium hydroxide 30%Sodium hypochlorite (Javel water)Sodium thiosulfateSulfonitric acid 100%Sulfuric acid 98%TetrachloroethyleneTetrahydrofuran (THF)TolueneTrichlorethyleneTrichloroacetic acidTrichloroethaneTrichloromethane (Chloroform)Triethylene glycolTrifluoroacetic acid (TFA)Xylene
Acura® 865
CalibrexTM 520/521AcurexTM 501
CalibrexTM 525/530
Extended chemical lists
www.socorex.com
The DosysTM syringes
Product advantagesnOptimal hand balance and ergonomicsnFast and reliable volume setting nExcellent reproducibilitynPlunger tightness without O-ringnHigh chemical resistancenFully autoclavable at 121°C / 250°F
Simple, natural movementsBoth pistol-grip and two-ring handles fit any hand in a comfortable way. Activation performed with limited effort for efficient work even during long dispensing series.
Syringe standStand holds syringe in ready-to-fetch position. Easy-to-clean material. Autoclavable (Cat. No. 320.170).
Volume selection – Reliable reproducibilityVolume is set within seconds. It will not vary while activating the syringe, thanks to the safety-locking nut on the micrometric screw. Dose-by-dose reproducibility (CV) is excellent, as witnessed by performance figures.
Plunger tightness without O-ringSmooth plunger travel and tightness achieved through high-precision stainless steel plunger and ground glass barrel. No O-ring to mess with or replace.
Glass protectionInterchangeable glass barrel is protected by a PVC sleeve (not autoclavable) to prevent breakage.
Few parts assembly – Low maintenanceThe automatic syringes are made of only six main parts, easy to disassemble. Fast access to all elements allows rapid and efficient cleaning. Spares are available at reasonable cost.
From the basic unit to the corrosion-resistant model, the laboratory dedicated syringe line offers precision instruments you can trust. Intended for safe and reliable liquid distribution, the selection of pistol-grip and two-ring instruments comes in a wide volume range. One-year warranty.
162 163 164
Two-ring handle
172 173 174Pistol-grip handle
1
1 2 5
3
4
6
3 4 5 62
laboratory syringesDosys™
26
Division Dosys 164Cat. No.
Dosys 174Cat. No.
174.0501174.0502174.0505174.0510
164.0501164.0502164.0505164.0510
0.05 mL0.1 mL0.5 mL1.0 mL
0.1 – 1 mL0.3 – 2 mL0.5 – 5 mL1 – 10 mL
VolumeVolume Division Dosys 162Cat. No.
Dosys 172Cat. No.
172.0501172.0502172.0505172.0510
162.0501162.0502162.0505
0.05 mL0.1 mL0.5 mL1.0 mL
0.1 – 1 mL0.3 – 2 mL0.5 – 5 mL1 – 10 mL
Division Dosys 163Cat. No.
Dosys 173Cat. No.
173.05003173.05005173.0501173.0502173.0505173.0510173.0520
163.05003163.05005163.0501163.0502163.0505163.0510
0.025 mL0.1 mL0.05 mL0.1 mL0.5 mL1 mL1 mL
0.025 – 0.3 mL0.1 – 0.5 mL0.1 – 1 mL0.3 – 2 mL0.5 – 5 mL1 – 10 mL5 – 2 0 mL
Volume
DosysTM basic syringes 162 / 172Fill-by-fill (automatic) through needle or cannulaSupplied without valve systemLuer Lock nozzle
Package includes syringe, PVC protection sleeve and operating instructions.
Dose-by-dose distribution
Dispensing distribution Sterile work Filtration at yournozzle tip
Aspiration with reverse modus valve
Animal injection
DosysTM classic syringes 163 / 173Self-refilling automaticIntegrated valve systemLuer Lock nozzle
Package includes syringe, one meter silicone feed tube, sinker, PVC protection sleeve, aspiration and vent cannulas, set of spares for valve, operating instructions.
DosysTM premium syringes 164 / 174Self-refilling automaticDetachable valve systemEnhanced corrosion resistanceLuer Lock nozzle
Package includes syringe, one meter silicone feed tube, sinker, PVC protection sleeve, aspiration, vent and dosing cannulas, set of spares for valve, operating instructions.
Parts
Feed tubingBarrelWasher, barrelPlungerValve systemWasher, valveSpring and balls, valveSinker, feed cannula
Basic / classic models
SiliconeBorosilicate glass
FPMStainless steel DIN 304
Ni-Cr BrassPTFE
Stainless steel, DIN 304Ni-Cr Brass
Premium models
SiliconeBorosilicate glass
FPMStainless steel DIN 316LStainless steel DIN 316L
PTFEStainless steel, DIN 304
Ni-Cr Brass
Liquid path materials (for chemical resistance)Performance all modelsVolume
Min. vol. Max. vol.< 0.5%< 0.4%< 0.4%< 0.4%< 0.2%< 0.2%< 0.4%
< 1.2%< 0.9%< 0.6%< 0.5%< 0.4%< 0.4%< 0.4%
< 1.8%1)
< 1.2%< 0.7%< 0.6%< 0.5%< 0.5%< 0.5%
0.025 – 0.3 mL0.1 – 0.5 mL0.1 – 1 mL0.3 – 2 mL0.5 – 5 mL1 – 10 mL5 – 20 mLTests performed with bidest. water, using stainless steel cannula (1.2x50 mm), at constant working speed. 1) Measured at 0.075 mL
Imprecision (CV%)Mid. vol.
DosysTM laboratory syringes – Unlimited applications
Instrument descriptions and ordering informationCorrosionresistantCorrosionresistant
27
Description
Set includes one each plunger, X-ring,5 mL barrel and greaseSpare barrel for tightness set, 5 mL
Packaging
1 / pk
6 / pk
Cat. No.
1.170.205
0187.05T
Description Packaging Cat. No.
Lubricant spray, 70 mL
1 / pk6 / pk12 / pk
1.170.7051.170.9061.170.912
Description Packaging Cat. No.
Lubricant spray, refill bottle, 500 mL
1 / pk6 / pk12 / pk
1.170.7551.170.9561.170.962
Size Ø x L, mm Packaging Cat. No.
3.0 x 180 mm3.0 x 500 mm
1 / pk1 / pk
370.30180370.30500
28
www.socorex.com
Multiple dispensing manifoldsFor convenient distribution in 24- and 96-well plates. Tight-fitting Luer and Luer Lock syringe nozzles. Stainless steel with PTFE stoppers, autoclavable.
Injection needlesBeveled, high-quality needles, stainless steel, autoclavable. 12 / pack.
Cannula with sprayer nozzleLuer Lock, stainless steel, autoclavable.
Dispensing needles & cannulasLuer Lock, stainless steel, autoclavable.
Cleaning brushesHeavy-duty nylon brushes with tufted end and plastic handle for barrel cleaning.
DrenchersFor safe animal mouth- and nose- feeding. Stainless steel, autoclavable.
Accessories for self-refilling syringes
Description
4-channel manifold,20 mm spacing8-channel manifold,9 mm spacing
Packaging
1 / pk
1 / pk
Cat. No.
1.170.054
1.170.058
ø x L, mm Cat. No.
371.0713371.0810371.0825371.0830371.0840371.1010371.1020371.1030371.1040371.1210371.1220371.1235371.1250
Additional sizes available
0.7 x 130.8 x 100.8 x 250.8 x 300.8 x 401.0 x 101.0 x 201.0 x 301.0 x 401.2 x 101.2 x 201.2 x 351.2 x 50
ø x L, mm Cat. No.
371.1420371.1435371.15150371.1620371.1625371.1630371.16100371.1810371.1820371.1830371.2030371.2040371.2050
1.4 x 201.4 x 351.5 x 1501.6 x 201.6 x 251.6 x 301.6 x 1001.8 x 101.8 x 201.8 x 302.0 x 302.0 x 402.0 x 50
Size (ø x L) Packaging
12 / pk1 / pk1 / pk1 / pk
1 / pk1 / pk1 / pk
Cat. No.
370.0840370.1250370.22100370.22150
371.1210UN371.1620UN371.2030UN
0.8 x 40 mm1.2 x 50 mm2.2 x 100 mm2.2 x 150 mm
1.2 x 10 mm1.6 x 20 mm2.0 x 30 mm
Lab cannulas, blunt end
Superior quality needles, bevelled
Size (ø x L) Packaging
3 / pk3 / pk2 / pk2 / pk
3 / pk3 / pk2 / pk2 / pk
Cat. No.
376.0925S376.1251S376.16102S376.30203S
376.0925B376.1251B376.16102B376.30203B
0.9 x 25 mm1.2 x 51 mm1.6 x 102 mm3.0 x 203 mm
0.9 x 25 mm1.2 x 51 mm1.6 x 102 mm3.0 x 203 mm
Drenchers, straight
Drenchers, bent
Alternative feed sourcesOptional vial holder conversion set and reagent reservoirs for additional liquid feeding possibilities.
Description
Vial holder conversion set for 163 and 173 models (except 20 mL), without vialPP bottle, 60 mLPP bottle, 125 mLPP bottle, 250 mL
Packaging
1 / pk
1 / pk1 / pk1 / pk
Cat. No.
1.187.1C
1.187.060*1.187.150*1.187.250*
*Use with Rotlauf inlet valve (Cat. No. 187.613) only, to be ordered separately.
Enhanced tightness setThe special clear glass barrel / X-ring fitted plunger enhance tightness when demanded by application (ex. filtration, aspiration, etc.).
Anti-Blocking Factor (ABF™) premium anti-corrosive lubricant Reduces instrument wear, provides efficient metal protection
Aspiration valveReverse modus valve set for liquid aspira-tion (ex. waste collection in separate con-tainer). Vented waste collector cap and enhanced tightness set recommended.
Description
Reverse modus aspiration valve unit for 164 / 174 modelsScrew cap ø 45 mm, with tubing connection and filtered air outlet
Packaging
1 / pk
1 / pk
Cat. No.
1.170.952
1.170.945
Description
For 0.3, 0.5, 1 mL barrelsFor 1, 2, 5 mL barrelsFor 5, 10, 20 mL barrelsSet of 6 nylon brushes, 2 each
Packaging
6 / pk6 / pk3 / pk6 / pk
Cat. No.
1.170.3011.170.3051.170.3201.170.300
1
1 2 3 5 6
7 8
2 3 4
9
5 6
7
8
4
9
10
10 11
11
accessoriesDosys™
155.0301
155.0305155.0310155.0320155.0330
155.03100
3 / pk3 / pk3 / pk3 / pk2 / pk2 / pk1 / pk1 / pk1 / pk1 / pk1 / pk
0.05 mL0.1 mL0.2 mL0.2 mL1 mL2 mL2 mL10 mL10 mL10 mL10 mL
0.1 - 1 mL0.5 - 2 mL0.2 - 5 mL1 - 10 mL1 - 20 mL1 - 30 mL1 - 50 mL10 - 100 mL10 - 150 mL10 - 200 mL10 - 250 mL
155.0501155.0502155.0505155.0510155.0520155.0530155.0550155.05100155.05150155.05200155.05250
Glass LuernozzleCat. No.
Volume Division Packaging Metal LuerLock nozzle
Cat. No.
Other spare partsRefer to separate list for exhaustive selection.
Includes springs, balls, washer for valve and barrel washer.
Description Packaging Cat. No.
6 / pk6 / pk6 / pk6 / pk6 / pk6 / pk3 / pk
0187.0030187.0050187.010187.020187.050187.100187.20
Barrel, syringe 0.3 mLBarrel, syringe 0.5 mLBarrel, syringe 1 mLBarrel, syringe 2 mLBarrel, syringe 5 mLBarrel, syringe 10 mLBarrel, syringe 20 mL
Description Packaging Cat. No.
1 bag1 bag1 bag1 bag1 bag1 bag1 bag
1.187.720031.187.720051.187.72011.187.72021.187.72051.187.72101.187.7220
Kit for valve, syringe 0.3 mLKit for valve, syringe 0.5 mLKit for valve, syringe 1 mLKit for valve, syringe 2 mLKit for valve, syringe 5 mLKit for valve, syringe 10 mLKit for valve, syringe 20 mL
Description Packaging Cat. No.
6 / pk6 / pk6 / pk6 / pk6 / pk3 / pk
1.170.40051.170.4011.170.4021.170.4051.170.4101.170.420
Sleeve, 0.3, 0.5 mL barrelsSleeve, 1 mL barrelsSleeve, 2 mL barrelsSleeve, 5 mL barrelsSleeve, 10 mL barrelsSleeve, 20 mL barrels
Description Packaging Cat. No.
1 / pk
1 / pk
1 / pk
1 / pk
1 / pk
Short vent cannulas
Long feed cannulas
187.933
187.591
187.593
187.592
187.594
Plastic / SS, syringes 0.3 to 5mLChrome plated, syringe 10 mLChrome plated, syringe 20 mL
Chrome plated, syringes 0.3 to10 mLChrome plated, syringe 20 mL
Description Packaging Cat. No.
1 m / pk3x 1 m / pk10 m / pk
by the meter1 m / pk
187.705187.905187.910187.710187.707
Tube, syringes 0.3 to 10 mL, cutTube, syringes 0.3 to 10 mL, cutTube, syringes 0.3 to 10 mL, uncutTube, syringes 0.3 to 10 mL, cutTube, syringe 20 mL, cut
The DosysTM all-glass syringes
The reusable borosilicate glass syringes offer superiorchemical and heat-shock resistance. A precious, low-cost alternative to disposable plastic syringes, complementing the self-refilling models in many applications.
Product advantagesnPrecision-machined plunger and barrelnExcellent fitting and liquid tightness (not gas tight) nPermanent, high-visibility graduationsnAutoclavable at 121°C / 250°F
Ground glass barrels
Spare parts for self-refilling syringes
Spare bags Vent and feed cannulas
1551 to 250 mL
PVC protection sleeves Feed tubing (medical quality silicone)
Ordering information
1
1
2 4
3 5
2 3 4 5
spare parts and all-glass syringesDosys™
29
www.socorex.com
The ProfillerTM electro 446
Product advantages nPowerful pump – fills 25 mL in 3 secondsnSimple, fast operation nComfortable finger triggersnLow battery lightnNiMH battery rechargeable during usenInterchangeable protection membrane filternStand suitable for bench or wall mounting
Battery chargeInstrument plug enables charging battery either in storage positionor during use.
Variable speedSwitch enables selection of fastor slow aspiration and dispensing(with blow-out). Fast speed filling upto 25 mL in under 3 seconds. Gravitydispense mode is designed for use with‘To Deliver’ (TD) pipettes.
Ordering information – InstrumentSupplied with power supply, two sparehydrophobic filters (0.45 µm and 0.2 µm), bench / wall stand and instruction manual.
Ordering information – Accessories
Finger triggersSuction and dispensing are controlled through two ergonomically positioned finger triggers. They provide a comfortable grip with minimum activation effort.
Convenient standSuitable for bench or wall mounting, stand houses ProfillerTM electro withor without a pipette in place.
Pipette controller fitting any hand in a very comfortable way. Shape is ideal for working with glass or plastic pipettes within laminar flow or microbiological safety cabinet. A powerful, yet quiet motor and a switch to set both aspiration and dispensing speeds enable maximal working efficiency even with large pipetting volumes.One-year warranty.
Description Packaging Cat. No.
1 / pk2 / pk
1 / pk
1 / pk
1 / pk
320.446900.916
900.946E
900.946G
900.946U
Spare standSpare 1.2V NiMH batteryPower supply, Europe style plugPower supply, UK style plugPower supply, USA-Japan style plug
Description Packaging Cat. No.
5 / pk5 / pk1 / pk3 / pk3 / pk
322.435322.4001.435.011.435.021.435.03
Membrane filter, 0.45µmMembrane filter, 0.2µmSilicone pipette holderNose cone – whiteAlternative nose conespink, violet, green (1 each)
ProfillerTM electro 446 Packaging Cat. No.
1 / pk1 / pk1 / pk
446.100E446.100G446.100U
With Europe style plugWith UK style plugWith USA/Japan style plug
446Pipettes
up to 100 mL
1
1
2 3
2 3
electronic pipette controllerProfiller™electro
30
Squeezable bulbSimply squeeze large capacity silicone bulb for efficient aspiration. If additional aspiration is needed, it can be squeezed even during pipetting.
Precise control Thumb lever button for left and right-handed users to easily control both aspiration and dispensing speeds.
Colour coding cones Nose cone can be changed for individ-ual, laboratory or department identifica-tion. Choose among regular white or a bunch of three colours.
Ordering information Accessories
Liquid blow-out Press large button to expel residual liq-uid when using blow-out type pipettes.
Pipette holder Conical shape of silicone pipette holder tightly fits graduated glass or plastic pipettes. Autoclavable.
Protection filter Interchangeable hydrophobic membrane filter guarantees effective protection against airborne contamination during aspiration and dispensing.
ProfillerTMmanual 435
Product advantages nLarge capacity bulbnSoft action lever buttonnEfficient blow-out systemnPTFE protection membrane filternMaintenance freenAlternative colour-coded nose cones
The ProfilletteTM 406
Product advantages nOne-hand operationnEasy filling and dispensingnAir inlet valve for fast distributionnColour coding per sizenMaintenance free
Robust and easy to use, this model offers ergonomic shape and light weight. It provides smooth control in both, aspirating and dispensing, using glass or plastic pipettes of volume up to 100 mL.One-year warranty.
435Pipettes
up to 100 mL
Ordering informationProfillette™ 406
Ordering informationProfiller™ 435
Description Packaging Cat. No.
1 / pk1 / pk
5 / pk5 / pk1 / pk3 / pk3 / pk
1.406.011.406.02
322.435322.4001.435.011.435.021.435.03
Profillette™ 406
Spare silicone pipette holderReplacement nose screwProfiller™ 435
Membrane filter, 0.45µmMembrane filter, 0.2µmSilicone pipette holderNose cone - whiteAlternative nose cones - pink, violet, green (1 each)
Description Packaging Cat. No.
1 / pk 435.100ProfillerTM 435,egg style grey bulb
manual
1
41
2
3
2 5
3
4 5
manual pipette controllerProfiller™manual
31
4062 mL
10 mL25 mL
Volumes Colours Packaging Cat. No.
1 / pk1 / pk1 / pk
3 / pack
bluegreenred
assorted
406.002406.010406.025406.300
2 mL10 mL25 mL2 / 10 / 25 mL
Ordering information - pipette tip selection
32
www.socorex.com
A perfect match between micropipettes and tips guaranteestrouble-free pipetting and reliable results. The Socorex Qualitips® are designed to fulfil above preconditions. The line is exclusively made from high grade, virgin, metal-free polypropylene. Precision injection moulding care for air-tight fit. Stringent quality procedures ensure lot by lot consistency.Various shapes in a range from 10 µL to 10 mL.
SizeCat. No.
70.9 mm
42.3 mm
31.0 mm
31.0 mm
302.0010GR
302.0020R
302.0020B
309.0010FR
309.0010R
309.0010B
45.6 mm302.0010FR302.0010AFB
Qualitips 10 µL
Qualitips 20 µL
Qualitips 100 µL
54.1 mm308.0100FR
69.0 mm308.0100GFR
SizeCat. No.Description
51.0 mm 308.0020FR
69.0 mm308.0020GFR
308.0020FS
SizeCat. No.Description
DescriptionFilterCapacityTip also fits Colour Style Unit Quantity
10 µL
10 µL
10 µL
10 µL
10 µL
10 µLBT, EP, GL
BT, EP, GL
Natural
Natural
Natural
Natural
Natural
Natural
No
No
No
Yes
No
No
No
No
No
Yes
No
No
Rack
Rack
Bag
Rack
Rack
Bag
4 x 204
10 x 96
1000
10 x 96
10 x 96
1000
Gel loading
Micro
10 µL10 µL
BR, EP, TF
BR, BT, EP
BR, BT, EP
BR, BT, EP,TF, GL
BR, EP, TFBR, EP, TF
NaturalNatural
YesYes
YesNo
RackBag
10 x 1001000
MicroMicro
Micro
Ultra-micro
Ultra-micro
Ultra-micro
SterilizedPackaging
100 µL Natural Yes Yes Rack 10 x 96Regular
100 µL Natural Yes Yes Rack 4 x 204Gel loading
FilterCapacityTip also fits Colour Style Unit QuantitySterilizedPackaging
20 µL Natural Yes Yes Rack 10 x 96Regular
20 µL Natural Yes Yes Rack 4 x 204Gel loading
20 µLBR, BT, EP, TF, GL
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
Natural Yes YesBag, single wrapped
5 x 100Regular
FilterCapacityTip also fits Colour Style Unit QuantitySterilizedPackaging
The Qualitips® pipette tipsfrom 10 µL to 10 mL
Product advantages nWide selection, superior qualitynLot-by-lot consistencynBulk or rack availabilitynCompatibility with various pipette brandsnHigh-density filter prevents aerosol contaminationnDNAse and RNAse-free filter tipsnPyrogen-free sterilized filter tips
Ask for free samples
pipette tipsQualitips®
33
Size QuantityCat. No.
308.0200R
308.0200B
307.0200B
327.0200R
327.0200B
328.0200R
328.0200B
309.0200R
309.0200B
308.0200GR
308.0200LFS
308.0200LFR
329.0200R
329.0200B
BR, BT, EP, TF
Qualitips 200 µL
SizeCat. No.
BR, BT, EP, GL
BR, BT, EP, GL
308.0350R
308.0350B
BR, BT, EP, GL
BR, BT, EP, GL
308.0300AFB
308.0300FR
Qualitips 300 / 350 µL
Size UnitCat. No.
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
307.1000R
307.1000B
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
309.1000R
309.1000B
Qualitips 1000 µL
BR, BT, EP, TF
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
319.1000R
319.1000B
BR, BT, EP, TF
51.1 mm
49.4 mm
49.4 mm
49.0 mm
49.7 mm
69.0 mm
90.9 mm
49.7 mm
88.6 mm
58.8 mm
58.8 mm
79.0mm
72.0 mm
72.0 mm
69.5 mm
BR, BT, EP, TF
318.1000R
318.1000B
FilterCapacityTip also fits Colour Style Unit
200 µL
200 µL
200 µL
Natural
Natural
Natural
No
No
No
No
No
No
Rack
Bag
Bag
10 x 96
1000
2 x 500
Regular
Regular
Graduated
200 µL
200 µL
Yellow
Yellow
No
No
No
No
Rack1)
Bag
10 x 96
2 x 500
Graduated
Graduated
200 µL
200 µL
200 µL
200 µL
Yellow
Yellow
Natural
Natural
No
No
No
No
No
No
No
No
Rack
Bag
Rack
Bag
10 x 96
2 x 500
10 x 96
2 x 500
Regular
200 µL Natural No No Rack 4 x 204Gel loading
200 µL
200 µL
Natural
Natural
Yes
Yes
Yes
Yes
Bag, single wrapped
Rack
5 x 100
8 x 204
Extended
Extended
Regular
Regular
Regular
200 µL
200 µL
Yellow
Yellow
No
No
No
No
Rack
Bag
10 x 96
2 x 500
Regular
Regular
Sterilized
Natural
Natural
Natural
Yes
Yes
Yes
Yes
Yes
No
Rack
Bag
Regular
Regular
Regular
Packaging
FilterCapacity Colour Style Unit Quantity
350 µL
350 µL
Natural
Natural
No
No
No
No
Rack
Bag
10 x 96
1000
Regular
Regular
300 µL
300 µL
Natural
Natural
Yes
Yes
No
Yes
Bag
Rack
1000
10 x 96
Regular
Regular
SterilizedPackaging
FilterCapacity
Tip also fits
Tip also fits Colour Style Quantity
1000 µL
1000 µL
Natural
Natural
No
No
No
No
Rack1)
Bag
10 x 60
4 x 250
Graduated
Graduated
1000 µL
1000 µL
Natural
Natural
No
No
No
No
Rack
Bag
8 x 60
4 x 250
Regular
Regular
SterilizedPackaging
1000 µL
1000 µL
Blue
Blue
No
No
No
No
Rack
Bag
8 x 60
4 x 250
Regular
Regular
1000 µL
1000 µL
Blue
Blue
No
No
No
No
Rack
Bag
8 x 60
4 x 250
Regular
Regular
Description
Description
Description
Tip also fitsCat. No.
Description Cat. No.PackagingLid typeFitting
F
E
312.10
312.02
G
150.0 mm
115.5 mm
123.2 mm
G
312.05R
312.05B
Qualitips 2 / 5 / 10 mLFilterCapacity Colour Style Unit Quantity
10 mL
2 mL
Natural
Natural
No
No
No
No
Bag
Bag
3 x 100
2 x 250
Regular
Regular
5 mL
5 mL
Natural
Natural
No
No
No
No
Rack
Bag
2 x 50
2 x 250
Graduated
Graduated
SterilizedPackagingDescription
Size
Empty autoclaving boxes
Tip fitting: BR = Brand®, BT = Biohit®, EP = Eppendorf®, FP = Finnpipette®, GL = Gilson®. Brand names belong to their respective owners.
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
BR, EP
BR, EP
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
BR, BT, EP, TF, GL
BR, BT, EP, TF 309.1000FS
309.1000FR
309.1000AFB
1000 µL
1000 µL
1000 µL
5x 100
10 x 100
1000
Bag, singlewrapped
Empty boxEmpty boxEmpty boxEmpty boxEmpty boxEmpty box
10 µL tips #309.0010B10 µL tips #302.0020B
200 µL tips #328.0200B350 µL tips #308.0350B1000 µL tips #319.1000B
10 mL tips #312.10
hingedcovercovercovercover
hinged
10 / pk10 / pk10 / pk10 / pk8 / pk4 / pk
309.0010ER302.0020ER328.0200ER308.0350ER319.1000ER312.10ER
pipette tipsQualitips®
www.socorex.com
34
309.0010B + R
309.0010FR
302.0020B + R
302.0010FR + AFB
302.0010GR
307.1000B + R
309.1000B + R
319.1000B + R
318.1000B + R
309.1000FR + FS + AFB
308.0020FS + FR
308.0020GFR
up to 1
0 µ
L
10 Y
/ 15 /
20 µ
L
25 to 1
00 µ
L
120 to 2
00 µ
L
250 to 1
000 µ
L
0.1
– 2
µL
0.5
– 1
0 µ
L
1 –
10 µ
L (Y
)
2 –
20 µ
L
5 –
50 µ
L
10 –
100 µ
L
20 –
200 µ
L
100 –
1000 µ
L
0.2
– 2
mL
0.5
– 5
mL
1 –
10 m
L
0.5
– 1
0 µ
L
5 –
50 µ
L
20 –
200 µ
L
40 –
350 µ
L
0.2
– 2
µL
1 –
10 µ
L
1 –
10 µ
L (Y
)
2 –
20 µ
L
10 –
100 µ
L
20 –
200 µ
L
100 –
1000 µ
L
0.2
– 2
mL
1 –
10 m
L
1 –
10 µ
L
10 –
100 µ
L
20 –
200 µ
L
Acura® manual and Acura® electro Calibra® digital
815 825/826/925/926 835/935/936 832 852855/955/956 822
Microtips, 20 µL
Microtips, 100 µL
308.0100FR
308.0100GFR
307.0200B
327.0200B + R
308.0200B + R
309.0200B + R
329.0200B + R
328.0200B + R
308.0200GR
308.0200LFS + LFR
308.0350B + R
308.0300FR + AFB
312.02 (2 mL)
312.05B + R (5 mL)
312.10 (10 mL)1) Only to max. volume of the tip 2) As of serial number 09091001 3) > 2 µL only
Microtips, 200 µL
Microtips, 300 / 350 µL
Microtips, 1000 µL
Microtips, 10 µL
Macrotips
x x x
x
x
xx
x
x
x
x x x x
x x
x x
x
x
x
x
x
x xx x x x xx x xx
x xx
x x xx
x x xx
x x xx
x x xx
xx
xx
xx
xx
x x x
x
x
xx
xx
xx
xx
xx
x x x xx
x x x xx
x x x x
x
x
x x x
x x
x
xx
x x xx
x xx
x xx
x x
x
x
x
xx
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
xx
x
x
xx
x
x
x
x
x x x
x
x x
x
x
x
x x
x
x
x
x x x
x
x
x
x
x
x
x3)
x3)
x1)
x1)
x1) x x1)
x1)
x1) x1)x1)
x1)
x1) x x1)
x1)x1)
x2)
x2)
x2)
x2)
x3)
Qualitips® compatibility chartChart below indicates optimal combination of Qualitips® and Socorex® pipette. Detailed compatibility with other pipette brands available on request. Please contact your local distributor or Socorex.
35
consumablesQualitips®
Straw tipsFitting the Acura® 810 dilution pipette, the long and thin shape straw tips allow pick-up of particle containing liquids in Stomacher® bags and deep, narrow reservoirs without blocking. Supplied sterilized in re-sealable bag.
Pasteur pipette adaptersDedicated PVDF adapters with two internal O-rings tightly fitting glass Pasteur pipette (ext Ø 6.5 – 7.2 mm), without excluding the use of regular PP tips.
Material
Glass
Glass with cotton plug
Fits macropipette
Acura® manual 835, 2 mLAcura® electro 936, 2 mL Calibra® digital 832, 2 mLAcura® manual 835, 5 mLAcura® electro 936, 5 mL
2 mL
2 mL
Volume
150 x 7230 x 7150 x 7230 x 7
Dimension (lxØ mm)
250/ pk250/ pk250/ pk250/ pk
Packaging
313.02.150313.02.230313.02.150C313.02.230C
Cat. No.
1.835.631
1.835.633
Cat. No.
1/ pk
1/ pk
Packaging
Description
Straw tips, 1.1 mL
Nozzle filterNozzle filterNozzle filter
Nozzle filter
Fits
Acura® manual 810
Acura® manual 810Calibra® digital 832, 2 mL
Acura® manual 835, 2 and 5 mLAcura® electro 935, 5 mL
Calibra® digital 832, 10 mLAcura® electro 935, 10 mL
Material
PP, sterilized
PECellulosePP fibre
PP fibre
Size (lxØ mm)
190 x 4
6.3 x 2.522 x 7
20 x 7.5
30 x 10.5
Packaging
40x 25/ pk
100/ pack250/ bag250/ bag
100/ bag
Cat. No.
313.1119.40
322.810322.02322.05
322.10
Glass Pasteur pipetteStandard 2 mL models fitting Acura® and Calibra® 2 and 5 mL macropipettes with their respective adapters. Useful alternative to macrotips, for instance when handling PP affecting reagents. Model and size selection fit most lab requirements.
5
5
6
6
2 3
3
Nozzle filters for pipettesProtection against liquid overflow or aerosol contamination. Filters are interchangeable, non-sterile, non autoclavable.
4
4
1
1 2
Ordering information - Pasteur pipettes Pasteur adapter
Ordering information - Straw tips and nozzle filters
www.socorex.com
36
Multichannel reagent reservoirs8 and 12 channel reservoirs provide ideal solutions for many applications. Sterilized PS material, single wrapped.
Description
ReservoirReservoirReservoirReservoir
58x132x25 mm83x121x34 mm83x126x13 mm83x126x13 mm
Dimensions
70 mL125 mL48 mL48 mL
Volume
NaturalNaturalWhiteWhite
Colour
V-shapedV-shaped8-channel12-channel
Style
NoYes, hinged
NoNo
Lid
PPPPPSPS
Materials
NoNoYesYes
Sterilized
20/ pack20/ pack
10x 1/ pack10x 1/ pack
Packaging
330.01330.01L330.08.9330.12.9
Cat. No.
All-purpose reagent reservoirsParticularly well suited for single and multichannel pipetting. V-shape bottom enables aspiration until last reagent drops. Made of PP, autoclavable, re-usable.
2
2
3
3
1
1
Ordering information - Reagent reservoirsPasteur adapter
37
Holder for two instrumentsThe attractive design accommodates all Calibra® and Acura® instruments, including microdispenser pipettes Acura® 865. A self-adhesive strip supplied ensures lasting attachment on any clean surface. Made of polycarbonate material.
Extended compatibility Work station 340 also accommodates the dilution pipette Acura® 810 andthe microdispenser pipettes Acura® 865. Heavy bottom plate and anti-slip pads guarantee high stability. Madeof polyamide material.
Colour Packaging Cat. No.
1 / pk4 / pk
320.332320.332.4
Transparent blueTransparent blue
Shelf pipette holder 332
1 / pk 320.340Light grey3 pipette work station 340
Ordering information
340
1 32 4
work stationspipette
Shelf pipette holder 332n2-positionnFitting micro, macro and multichannel pipettes
Static work station 340n3-positionnFitting micro, macro and/or multichannel Socorex pipettesnEasy reach of each instrument
Properly storing micropipettes prevents damages and extends their life span. Socorex® offers a choice of stands adapted to any laboratory configuration.
332
1 32 4
www.socorex.com
38
Universal storage solutionNo more micropipettes laying on the bench thanks to universal stands.They accommodate Socorex® andother brand micropipettes. Simpledisassembling and cleaning.
Smooth rotationStand includes mechanism enabling soft rotation with the fingertip.For quick selection and pickingof the desired micropipette.
Colour Packaging Cat. No.
1 / pk1 / pk1 / pk1 / pk1 / pk1 / pk1 / pk
320.336R320.336O320.336Y320.336G320.336B320.336Q320.336W
Rubin redTopaz orangeCitrine yellowEmerald greenSapphire blueQuartz greyDiamond white
1 / pk1 / pk1 / pk1 / pk1 / pk
320.337G320.337R320.337B320.337M320.337Y
Light greyPastel roseIce blueMint greenVanilla yellow
TwisterTM universal 336
In-line universal 337
Ordering information In-line universalityOne fits all; the stand holds newand old generations of Socorex®and other brand micropipettes.
337
1
1
2
2 3
3
4
4
TwisterTM universal 336n6-positionn360° soft rotationnInstruments easy to fetchnConcept fits pipettes of most brandsnInterchangeable discsnSeven translucent colours
In-lineTM universal 337n7-positionnHolds single channel pipettes of most brandsnSpace saving pipette standnSturdy polyamide materialnFive attractive pastel colours
The two universal micropipette stands fit all brands, ensuringtheir proper storage at any time. Anti-slip pads guarantee bench stability. Easy to clean.
336
39
Broad calibration programmeWhatever the maintenance level needed for micropipettes and dispensers, Socorex has the appropriate answer, including customised service plans when required.
Efficient handlingThe lead time for instruments received at Socorex is three to five working day, or 48 hours using our “Express service”.
Service Center on the webFor more details about our service pro-gramme, check: www.socorex.com
Personalised technical supportHighly qualified personnel with a broad product knowledge is at disposal for all technical matters. The team also provides professional answers and solutions about handling, maintenance and control procedures.
SCS accredited laboratory Accredited by SAS (Swiss Accreditation Services), the Socorex QC laboratory performs calibrations in full compliance with ISO 17025 and delivers control certificates recognized internationally by ILAC members.
Examples of ILAC members from signatory countries
AdvantagesnKnow-how and high competencenAll brand service for pipettes and dispensersnBroad programmenControls according to ISO 8655 and ISO 17025 standardsnSAS accredited QC laboratory
Socorex instruments are built to last. In order to guarantee trouble free usage over time, a minimum maintenance and regular calibration are strongly recommended. From rapid check-up or basic repair to GLP requirements, the Socorex Service Center - in its ultra-modern facilities - provides fast and reliable service and calibration, based on a long term experience in manufacturing precision liquid handling instruments.
OrganisationCountry
AustraliaAustriaBelgiumBrazil
CanadaChina
China HKCroatia
Czech RepublicDenmarkFinlandFrance
GermanyHungary
IndiaIndonesia
IrelandItaly
JapanNetherlands
NorwayPoland
PortugalSouth Africa
SloveniaSpain
SwedenSwitzerland
TurkeyUnited Kingdom
USA
NATABMWABELAC
CGCRE / INMETROSCC-CLAS
CNASHKASHAACAI
DANAKFINAS
COFRACDAkkSNATNABLKANINABSIT
IA-JAPANRvANAPCAIPAC
SANASSA
ENACSWEDAC
SASTURKAK
UKASNVLAP
Complete list and details under www.ILAC.org
service programmeSocorex Service Center
www.socorex.com
40
Procedures
Service levels Maintenance and control per ISO 8655
StandardCheck-up
•• • • • • • • •
•• • • •
10 x5 x
5 x
5 x
10 x
10 x 3)
10 x 10 x
10 x 10 x
10 x 3)
10 x 10 x
10 x
10 x 3)
10 x
10 x
10 x 3)
10 x
ISO 17025
10 x
10 x 3)
10 x
10 x
10 x
10 x 10 x
10 x 3)
10 x
4 x 2)
4 x 2) 10 x
10 x
10 x 3)
10 x
• • • •
• • • •
-
-
--
• • • •
• • • • • • • •
• • • • • • • •
•• • • • • • • •
••
•
• • • •
• •
• • •
•
•
• • • • •
• • • •
Classic Premium Advanced UltraUltraSCS
Newinstruments
2) Five measurements, multichannel below 50µL 3) When applicable1) On request
Instrument registration
Gravimetric test beforemaintenance (“as found”)
Decontamination 1), disinfection,disassembling, cleaning
Instrument check-up
X-ring replacement as needed
Other faulty parts replacement as needed
Function and tightness check
Gravimetric test aftermaintenance per ISO 8655
Gravimetric test after maintenance per ISO 17025
Final check and visa
QC certificate before maintenance (“as found”)
QC certificate after calibration (“as left”)
Accredited certificate per ISO 17025
Min. vol.
Min. vol.
Mid. vol.
Mid. vol.
Max. vol.
Mid. vol.
Max. vol.
Min. vol.
Max. vol.
Classic SCS
Premium SCS
Accredited calibration per ISO 17025
Accreditedcertificate
to beordered
withinstrument
Service programme
Standard serviceRepair, maintenance, control and calibration, 2x4 measurements, with QC certificate.
The cost-effective solutionfor any liquid handling instrument.
Check-upControl, 3x 5 measurements,
with detailed certificate before main-tenance («as found»).
Adequate for rapid instrument evaluation.
Classic serviceCleaning and maintenance,
control and calibration, 2x 10 measurements,
with detailed QC certificate.
Recommended as routine check.
Classic SCS serviceSame as above, but withISO 17025 calibration and SCS accredited certificate.
Alternative routine check when dealing with ISO 17025 pro-
cedures, or when mastering uncertainties
is required.Ultra SCS service
Same as above with ISO 17025 calibration and SCS accredited certificate.
Ultimate service when dealing with ISO 17025 for GLP environ-ment demanding analytical results.
Premium SCS service
Same as above, but with ISO 17025 calibration andSCS accredited certificate.
A must for laboratories dealing with ISO 17025 procedures, or
when mastering uncertainties is required. Available for new
instruments as well.
Premium service
Cleaning and maintenance, control and calibration, 3x10 mea-
surements, with detailed QC certificate.
An in-depth check, also including mid-range measurements.
A choice of service levels
Advanced serviceControl, 2x10 measurements, with
detailed certificate before maintenance (“as found”). Then cleaning, maintenance and calibration,
2x10 measurements, with detailed QC certificate.
Perfect for instruments used in GLP environments or for validation of critical analytical results.
Ultra serviceControl, 3x 10 measurements, with detailed certificate
before maintenance (“as found”). Then cleaning, mainte-nance and calibration, 3x10 measurements,
with detailed QC certificate.
Ultimate service for GLP environment when analytical results are demanded.
Cat. No. Page
0187.003 29
0187.005 29
0187.01 29
0187.02 29
0187.05 29
0187.05T 28
0187.10 29
0187.20 29
1.170.054 18/28
1.170.058 18/28
1.170.205 28
1.170.300 28
1.170.301 28
1.170.305 28
1.170.320 28
1.170.4005 29
1.170.401 29
1.170.402 29
1.170.405 29
1.170.410 29
1.170.420 29
1.170.705 28
1.170.755 28
1.170.906 28
1.170.912 28
1.170.945 28
1.170.952 28
1.170.956 28
1.170.962 28
1.187.060 28
1.187.150 28
1.187.1C 28
1.187.250 28
1.187.72003 29
1.187.72005 29
1.187.7201 29
1.187.7202 29
1.187.7205 29
1.187.7210 29
1.187.7220 29
1.406.01 31
1.406.02 31
1.411.7 17
1.435.01 30/31
1.435.02 30/31
1.435.03 30/31
1.524 23
1.525.120 23
1.525.121 23
1.525.150 23
1.525.151 23
1.525.525 24
1.525.526 24
1.525.546 23
1.525.581 23
1.525.625 23
Cat. No. Page
1.525.650 23
1.525.GL32 24
1.525.GL38 24
1.525.GL40 24
1.825.025 8
1.825.100 8
1.825.700 9
1.825.710 9
1.825.711 9
1.825.712 9
1.825.713 9
1.825.714 9
1.825.715 9
1.825.716 9
1.825.717 9
1.825.718 9
1.825.719 9
1.825.720 9
1.825.721 9
1.825.722 9
1.825.723 9
1.831.707 6
1.835.631 6/35
1.835.633 6/35
1.861.21T 18
1.861.631 18
1.861.720 18
1.861.925 18
1.861.E32 18
155.0301 29
155.0305 29
155.0310 29
155.03100 29
155.0320 29
155.0330 29
155.0501 29
155.0502 29
155.0505 29
155.0510 29
155.05100 29
155.05150 29
155.0520 29
155.05200 29
155.05250 29
155.0530 29
155.0550 29
162.0501 27
162.0502 27
162.0505 27
163.05003 27
163.05005 27
163.0501 27
163.0502 27
163.0505 27
163.0510 27
164.0501 27
Cat. No. Page
164.0502 27
164.0505 27
164.0510 27
172.0501 27
172.0502 27
172.0505 27
172.0510 27
173.05003 27
173.05005 27
173.0501 27
173.0502 27
173.0505 27
173.0510 27
173.0520 27
174.0501 27
174.0502 27
174.0505 27
174.0510 27
187.591 29
187.592 29
187.593 29
187.594 29
187.705 29
187.707 29
187.710 29
187.905 29
187.910 29
187.933 29
302.0010AFB 32
302.0010FR 32
302.0010GR 32
302.0020B 32
302.0020ER 33
302.0020R 32
307.0200B 33
307.1000B 33
307.1000R 33
308.0020FR 32
308.0020FS 32
308.0020GFR 32
308.0100FR 32
308.0100GFR 32
308.0200B 33
308.0200GR 33
308.0200LFR 33
308.0200LFS 33
308.0200R 33
308.0300AFB 33
308.0300FR 33
308.0350B 33
308.0350ER 33
308.0350R 33
309.0010B 32
309.0010ER 33
309.0010FR 32
309.0010R 32
Cat. No. Page
309.0200B 33
309.0200R 33
309.1000AFB 33
309.1000B 33
309.1000FR 33
309.1000R 33
309.100FS 33
312.02 33
312.05B 33
312.05R 33
312.10 33
312.10ER 33
313.02.150 35
313.02.150C 35
313.02.230 35
313.02.230C 35
313.1119.40 13/35
314.0100 24
314.0250 24
314.0250C 24
314.0500 24
314.0500C 24
314.0500P 24
314.0500PE 24
314.1000 24
314.1000C 24
314.1000PE 24
314.2000C 24
314.2500 24
314.2500H 24
314.2500PE 24
315.0250 24
315.0500 24
315.1000 24
315.2500 24
316.010 17
316.010.9 17
316.050 17
316.050.9 17
316.500 17
316.500.9 17
318. 1000B 33
318. 1000R 33
319. 1000B 33
319. 1000R 33
319.1000ER 33
320.332 13/37
320.332.4 13/37
320.333 16
320.336B 38
320.336G 38
320.336O 38
320.336Q 38
320.336R 38
320.336W 38
320.336Y 38
Cat. No. Page
320.337B 38
320.337G 38
320.337M 38
320.337R 38
320.337Y 38
320.340 13/18/37
320.411 17
320.446 30
320.903.48 6
320.913.48 6
320.BC050 23
320.BC100 23
320.SB050 23
320.SB100 23
322.02 35
322.05 6/35
322.10 6/35
322.400 30/31
322.435 30/31
322.810 13/35
327.0200B 33
327.0200R 33
328.0200B 33
328.0200ER 33
328.0200R 33
329.0200B 33
329.0200R 33
330.01 36
330.01L 36
330.08.9 36
330.12.9 36
341.005 16
341.025 16
341.050 16
341.100 16
341.200 16
342.005 16
342.025 16
342.050 16
342.100 16
342.200 16
370.0840 28
370.1250 28
370.22100 28
370.22150 28
370.30180 28
370.30500 28
371.0713 28
371.0810 28
371.0825 28
371.0830 28
371.0840 28
371.1010 28
371.1020 28
371.1030 28
371.1040 28
Cat. No. Page
371.1210 28
371.1210UN 28
371.1220 28
371.1235 28
371.1250 28
371.1420 28
371.1435 28
371.15150 28
371.16100 28
371.1620 28
371.1620UN 28
371.1625 28
371.1630 28
371.1810 28
371.1820 28
371.1830 28
371.2030 28
371.2030UN 28
371.2040 28
371.2050 28
376.0925B 28
376.0925S 28
376.1251B 28
376.1251S 28
376.16102B 28
376.16102S 28
376.30203B 28
376.30203S 28
406.002 31
406.025 31
406.010 31
406.300 31
411.5000 17
435.100 31
446.100E 30
446.100G 30
446.100U 30
501.02025 19
501.021 19
501.022 19
501.0505 19
501.051 19
501.052 19
501.101 19
501.102 19
501.302 19
511.707 24
511.709 24
520.002 20
520.005 20
520.010 20
520.F02 20
520.F05 20
520.F10 20
521.621 24
521.622 24
catalogue number indexProduct references
Dear Partner in science,
This new Socorex 2015-2016 edition features a number of innovations you will enjoy discovering and using in your liquid dosing applications.
Made of sturdy materials, well thought out in terms of functions and metrological performance, the Calibrex™ organo and solutae bottle-top dispensers have rapidly and successfully proven themselves in the hands of demanding scientists.
Overcoming even tricky liquids, the new positive displacement micropipettes Acura® capillar 846 is a high performance instrument enabling trouble-free handling of viscous liquids, foaming solutions and volatile solvents.
Significant progress has been made with our long established international partner network, adding new forces where needed. Their details are listed in the Distributor section of our web site. Highly qualified, well documented and equipped to provide the best advice and technical support, they work hand in hand with the thousands of end-users trusting Socorex throughout the world.
I seize the opportunity to pay a special tribute to both communities for their loyalty and contribution to our successful growth over so many years.
Sincerely
Sylvain Christen, CEO
Products & services
Today’s manufacturing programme includes a wide variety of high precision instruments used for reliablymeasuring, dosing, transferring, dispensing and injecting liquids in a large number of applications.
Manual and electronic micropipettes, single and multichannel pipettors, repeater pipettes, dispensers, pipette controllers and re-usable syringes, together with their accessories, constitute the heart of the programme.
Each precision instrument bears its own serial number and passes a strict performance control attested by an individual QC certificate.
The Socorex Service Center offers a global repair and calibration programme. The choices range from basic maintenance to accredited calibrations of all micropipettes and dispensers according to ISO 17025 – whatever their brand.
Welcome to Socorex – a world of expertise in prec
Sylvain Christen, CEO
Laurence Louy-Drevici, Business Development
Jean-Pierre Uldry, Director of Engineering
Aurelie Stangoni, Customer Service
Beatriz Grasset, Sales Administration Manager
Tatjana Van Bogaert, CEO Assistant
Pascal Durand, Admin. and Finance Manager
Thérèse Valenziano, Customer Service
Cat. No. Page
521.623 24
521.705 24
521.706 24
525.025 22
525.025FC 22
525.050 22
525.050FC 22
525.100 22
525.100FC 22
525.350 24
525.706 24
530.025 22
530.025FC 22
530.050 22
530.050FC 22
530.100 22
530.100FC 22
800.0002 6
800.0002XS 6
800.0010 6
800.0010XS 6
800.0010Y 6
800.0010YXS 6
800.0020 6
800.0020XS 6
800.0050 6
800.0050XS 6
800.0100 6
800.0100XS 6
800.0200 6
800.0200XS 6
800.08.010 6
800.08.050 6
Socorex® Instruments US Patents
Acura® models 810, 815, 825, 826 XS, 835, 835F, 855, 865 7,204,163 B2
Acura® models 810, 815, 825, 826 XS, 835, 835F, 855, 926 XS, 936, 956 6,833,114 B1
Acura® models 826XS.0200, 826XS.1000 8,900,526 B2
Acura® models 926XS.0200, 926XS.1000
Calibrex ™ models 525, 530 Pending
Socorex® Calibra® ABF ™ Calibrex ™ Jet-Pen ™ Stepper ™
Isba® Qualitips® Acurex ™ Dosys ™ Justip ™
Acura® Socorex Stepper® bioproof ™ Ecostep ™ Profiller ™
Other brand names contained in this catalogue belong to their respective owners.
Cat. No. Page
800.08.200 6
800.08.350 6
800.1000 6
800.10000 6
800.1000XS 6
800.12.010 6
800.12.050 6
800.12.200 6
800.12.350 6
800.2000 6
800.5000 6
810.1100 13
815.0001 11
815.0005 11
815.0010 11
815.0010Y 11
815.0015 11
815.0020 11
815.0025 11
815.0030 11
815.0032 11
815.0040 11
815.0050 11
815.0060 11
815.0070 11
815.0075 11
815.0080 11
815.0090 11
815.0100 11
815.0120 11
815.0150 11
815.0200 11
815.0250 11
Cat. No. Page
815.0300 11
815.0400 11
815.0500 11
815.0600 11
815.0700 11
815.0750 11
815.0800 11
815.0900 11
815.1000 11
822.0002 14
822.0010 14
822.0010Y 14
822.0020 14
822.0100 14
822.0200 14
822.1000 14
825.0002 8
825.0010 8
825.0010Y 8
825.0020 8
825.0050 8
825.0100 8
825.0200 8
825.1000 8
825.TRIO.C 9
825.TRIO.J 9
825.TRIO.M 9
825.TRIO.O 9
825.TRIO.P 9
825.TRIO.S 9
825.TRIO.T 9
825.TRIO.V 9
826.0002 8
Cat. No. Page
826.0010 8
826.0010Y 8
826.0020 8
826.0050 8
826.0100 8
826.0200 8
826.1000 8
826.TWX.E 9
826.TWX.G 9
826.TWX.H 9
826.TWX.K 9
826.TWX.N 9
826.TWX.Q 9
832.02 14
832.10 14
835.02 10
835.05 10
835.02PP 10
835.05PP 10
835.10 10
835.F02 11
835.F02.5 11
835.F05 11
835.F10 11
835.TRIO.Y 9
841.005 16
841.025 16
841.050 16
841.100 16
841.200 16
852.08.010 15
852.08.100 15
852.08.200 15
Cat. No. Page
852.12.100 15
852.12.200 15
855.08.010 12
855.08.050 12
855.08.200 12
855.08.350 12
855.12.010 12
855.12.050 12
855.12.200 12
855.12.350 12
865.0050 18
865.0200 18
865.1000 18
900.901.48A 6
900.901.48E 6
900.901.48G 6
900.901.48U 6
900.916 30
900.920.48 6
900.922.48 6
900.946E 30
900.946G 30
900.946U 30
926.0002 6
926.0002E 6
926.0010 6
926.0010E 6
926.0010Y 6
926.0010YE 6
926.0020 6
926.0020E 6
926.0050 6
926.0050E 6
Cat. No. Page
926.0100 6
926.0100E 6
926.0200 6
926.0200E 6
926.1000 6
926.1000E 6
936.02 6
936.02E 6
936.05 6
936.05E 6
936.10 6
936.10E 6
956.08.010 6
956.08.010E 6
956.08.050 6
956.08.050E 6
956.08.200 6
956.08.200E 6
956.08.350 6
956.08.350E 6
956.12.010 6
956.12.010E 6
956.12.050 6
956.12.050E 6
956.12.200 6
956.12.200E 6
956.12.350 6
956.12.350E 6
GLP + Ø 24
GLT + Ø 24
NSP + Ø 24
NST + Ø 24
Patents and Trade marks
www.socorex.com
Brief history
Socorex Isba SA, often referred to as just Socorex per its original name, was first founded in the late 1940s. Two young watchmakers had identified the need for new types of quality syringes for medical applications. The products rapidly met international success. In search of synergies, the company subsequently merged with another firm, moved to the city of Lausanne on Lake Geneva, changed name to become Socorex Isba SA and finally, under a new family ownership, built up-to-date premises in Ecublens – we are in 1963. Fifty years later, still with the same shareholders, Socorex has grown its two distinct laboratory and animal health divisions, reflecting a long time strategic reconversion. An important 50 th anniversary year, 2013 marked the inauguration of a major facility improvement programme. This included the construction of a new administration building and production plant expansion. Enlarged, the modern site will support the company’s capacity to handle many more success stories in the future.
y o u r q u a l i t y p a r t n e r w o r l d w i d e
precision� volumetryElectronic micropipettes
Positive displacement pipettes
Digital setting micropipettes
Repeater pipette
Microdispenser pipettes
Low profile dispensers
Bottle-top dispensers
Laboratory syringes
Pipette controllers
Pipette tips / consumables
Work stations
Service center
Digital reading micropipettes
SOCOREX ISBA SAChamp-Colomb 7, P.O. Box 3781024 Ecublens/[email protected]. +41 (0)21 651 6000Fax +41 (0)21 651 6001
C.G
EN.E
�–�F
415
Your local distributor
Important information
Refer to package inserts for safety precautions, operating instructions and warranty terms.
User must pay special attentionto possible hand fatigue during serial pipetting and its medical consequences such as repetitive strain injuries (RSI).
Mind risks involved in handling hazardous liquids with respect to personal, third party andenvironmental protection and safety.
Products and specifications are subject to change without prior notice.
Copyright�©�2015�by�Socorex�Isba�SA,�Switzerland
20
15
-20
16
PR
EC
ISIO
N L
IQU
ID H
AN
DL
ING
liquid