2
GEL VRLA Deep Cycle Batteries * Specially designed for military tanks, panzers and other military vehicles. Deep Discharge means a discharge situation which decrease to %20 of battery’s nominal capacity. More deep discharge causes Electrolite Type: Gel - 1,75 VDC @ (A) <=0,2 C–Storage Time: 6 months @ 25 0 C Self Discharge: Less Than %2 per month @ 25 0 C- Float Cell Voltage (VDC @25 0 C): 2,25 – Cycle Cell Voltage(VDC @25 0 C): 2,30-2,35 Equalization Cell Voltage(VDC @25 0 C): 2,40-2,45 Gel energy, used in the solar energy systems / Marine battery in yacht, sea transports / Wind energy systems / Defense industry like military tanks, panzers, sea boats / Wheel chairs / Heavy Construction Machines / Intercity autobus / Charged transpallet / Uninterruptable Power Supplies / Generators / Cleaning vehicle / Golf cars / Greenhouses / Deep cycling applications/ Briefly, every moment in life… Gel Energy is full maintenance free and has no maintenance cost. It provides absolute solution for acid evacuation from the battery. It can work in spite of partially broken situation and also works excellently in the vibration working areas. It can be fully returned from deep discharge even if the battery isn’t charged immediately. It has low inner resistance. It can be used to store the energy which is gained from alternative energy (sun, wind, etc...) for the later usage. YGE12-40 25402021E 12 40 L1 15,6 40,0 38,1 35,2 32,5 A-S 207/175/167-190 Gel VRLA Deep Cycle Batteries 6V - 12V Series Code Design Number Voltage (V) Capacity (Ah) Weight (Kg) (+-%3) Dimensions L/W/H (mm) Terminal Type Box Type Capacities (Ah) C20 C10 C5 C3 YGE12-50 25502106E 12 50 L2 18,1 50,0 46,4 41,8 39,3 A-S 242/175/167-190 YGE12-60 25602160E 12 60 L3 21,7 60,0 56,8 52,3 48,9 A-S 276/175/167-190 YGE12-80 25802034E 12 80 L5 27,8 80,0 73,9 67,8 64,7 A-S 352/175/167-190 YGE12-95 25952015E 12 95 L6 30,5 95,0 87,1 78,4 74,2 A-S 393/175/167-190 YGE12-100 26002108E 12 100 D2 32,7 100,0 88,9 79,6 75,8 A-S 350/173/210-232 YGE12-120 26202054E 12 120 A 41,7 120,0 110,3 101,2 96,3 A-S 509/189/193-216 YGE12-100T* 26202074E 12 100 (C5) D7 40,1 120,0 112,5 100 94,3 A-S 284/265/205-224 YGE12-120T* 26202072E 12 120 (C20) D7 40,1 120,0 112,5 100 94,3 A-S 284/265/205-224 YGE12-130 26302008E 12 130 D2H 42,0 130,0 121,7 111,8 102,1 A-S 345/173/262-284 YGE12-150 26502061E 12 150 B 48,6 150,0 138,8 127 117,4 A-S 509/224/195-218 YGE12-200 27002042E 12 200 C 73,6 200,0 185,8 169,3 155,2 A-S 518/273/213-236 YGE12-235 27352001E 12 235 C 76,1 235,0 218,6 200,3 182,8 A-S 518/273/213-236 YGE8-145 29452001E 8 145 GU 32,7 145,0 134,2 125,2 113,5 A-S 265/183/252-274 YGE6-200 27002064E 6 200 GU 35,1 200,0 190,2 162,8 155 A-S 265/183/252-274

GEL VRLA Deep Cycle Batteries...Organize Sanayi Bölgesi Oğuz Caddesi No: 2 Sincan / Ankara - TURKEY Tel : +90 312 267 02 80 - Fax: +90 312 267 08 61 - 267 40 00 [email protected]

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GEL VRLA Deep Cycle Batteries...Organize Sanayi Bölgesi Oğuz Caddesi No: 2 Sincan / Ankara - TURKEY Tel : +90 312 267 02 80 - Fax: +90 312 267 08 61 - 267 40 00 endustriyel@yigitaku.com

GEL VRLA Deep Cycle Batteries

* Specially designed for military tanks, panzers and other military vehicles.

Deep Discharge means a discharge situation which decrease to %20 of battery’s nominal capacity. More deep discharge causes

Electrolite Type: Gel - 1,75 VDC @ (A) <=0,2 C–Storage Time: 6 months @ 250C Self Discharge: Less Than %2 per month @ 250C- Float Cell Voltage (VDC @250C): 2,25 – Cycle Cell Voltage(VDC @250C): 2,30-2,35 Equalization Cell Voltage(VDC @250C): 2,40-2,45

Gel energy, used in the solar energy systems / Marine battery in yacht, sea transports / Wind energy systems / Defenseindustry like military tanks, panzers, sea boats / Wheel chairs / Heavy Construction Machines / Intercity autobus / Chargedtranspallet / Uninterruptable Power Supplies / Generators / Cleaning vehicle / Golf cars / Greenhouses / Deep cycling applications/ Briefly, every moment in life…

Gel Energy is full maintenance free and has no maintenance cost. It provides absolute solution for acid evacuation from the battery. It can work in spite of partially broken situation and also works excellently in the vibration working areas. It can be fully returned from deep discharge even if the battery isn’t charged immediately. It has low inner resistance. It can be used to store the energy which is gained from alternative energy (sun, wind, etc...) for the later usage.

YGE12-40 25402021E 12 40 L1 15,6 40,0 38,1 35,2 32,5 A-S207/175/167-190

Gel VRLA Deep Cycle Batteries 6V - 12V Series

CodeDesignNumber

Voltage(V)

Capacity(Ah)

Weight(Kg) (+-%3)

DimensionsL/W/H (mm)

TerminalType

BoxType

Capacities (Ah)

C20 C10 C5 C3

YGE12-50 25502106E 12 50 L2 18,1 50,0 46,4 41,8 39,3 A-S242/175/167-190

YGE12-60 25602160E 12 60 L3 21,7 60,0 56,8 52,3 48,9 A-S276/175/167-190

YGE12-80 25802034E 12 80 L5 27,8 80,0 73,9 67,8 64,7 A-S352/175/167-190

YGE12-95 25952015E 12 95 L6 30,5 95,0 87,1 78,4 74,2 A-S393/175/167-190

YGE12-100 26002108E 12 100 D2 32,7 100,0 88,9 79,6 75,8 A-S350/173/210-232

YGE12-120 26202054E 12 120 A 41,7 120,0 110,3 101,2 96,3 A-S509/189/193-216

YGE12-100T* 26202074E 12 100 (C5) D7 40,1 120,0 112,5 100 94,3 A-S284/265/205-224

YGE12-120T* 26202072E 12 120 (C20) D7 40,1 120,0 112,5 100 94,3 A-S284/265/205-224

YGE12-130 26302008E 12 130 D2H 42,0 130,0 121,7 111,8 102,1 A-S345/173/262-284

YGE12-150 26502061E 12 150 B 48,6 150,0 138,8 127 117,4 A-S509/224/195-218

YGE12-200 27002042E 12 200 C 73,6 200,0 185,8 169,3 155,2 A-S518/273/213-236

YGE12-235 27352001E 12 235 C 76,1 235,0 218,6 200,3 182,8 A-S518/273/213-236

YGE8-145 29452001E 8 145 GU 32,7 145,0 134,2 125,2 113,5 A-S265/183/252-274

YGE6-200 27002064E 6 200 GU 35,1 200,0 190,2 162,8 155 A-S265/183/252-274

Page 2: GEL VRLA Deep Cycle Batteries...Organize Sanayi Bölgesi Oğuz Caddesi No: 2 Sincan / Ankara - TURKEY Tel : +90 312 267 02 80 - Fax: +90 312 267 08 61 - 267 40 00 endustriyel@yigitaku.com

Yiğit Akü A.Ş.

Organize Sanayi Bölgesi Oğuz Caddesi No: 2 Sincan / Ankara - TURKEY Tel : +90 312 267 02 80 - Fax: +90 312 267 08 61 - 267 40 [email protected]

Terminal Type ADIN 72311-4 Round Type

Terminal Type S(M-8 Optional)

Temperature - BatteryUsing Life Relation

15

10

5

2

1

0.5 20 30 40 50 0C

Environment temperature

Batt

ery

Usi

ng L

ife (Y

ear)

3500

3000

2500

2000

1500

1000

500

020

% Depth of Discharge

Cycl

es

Cycle Life vs Depth ofDischarge +250C

50 80

3200

1500

650

-40 -30 -20 -10 0 10 20 30 40 50 60

%120

%100

%80

%60

%40

%20

%0

Ambient Temperature (0C)

Perc

enta

ge o

f Ava

ilabl

e Ca

paci

ty

Capacity vs. Operating Temperature

Special gel formula protects plates against overheat caused by overcharging compare to standard batteries. In Gel Energy there is no any kind of energy loss during the operational life. Self-discharge of Gel Energy is very low rate and could be kept in the shelf for a long time. It also could be protected %80 of nominal capacity during 6 months shelf-life. It is clean, natural energy and environ-mental friendly compared with the environmental harm by the fossil fuels.

400C

100

Capa

city

(%)

Storage Time (months)

80

60

40

20

02 4 6 8 10 12 14 16 18 20 22 24

300C

200C

100C

00CSupplementary charge required (Carryout supplementary charge before us e if 100% capacity is required)

Supplementary charge required before use. This supplementary charge will help to recover the capacity and should be made as early as possible.

Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this state is reached