Engine Make & Model:
Circuit Breaker Type:
Fuel Tank Capacity: litres (US gal)
Frequency: zH 06zH 05
Fuel Consumption, Prime: l/hr (US gal/hr)
Engine Speed: RPM
Base Frame Type:
Fuel Consumption, Standby : l/hr (US gal/hr)
Heavy Duty Fabricated Steel
Alternator Model:
Control Panel:
Output Ratings
Generating Set Model - 3 Phase Standby*Prime*
* Refer to ratings definitions on page 4. Ratings at power factor.
Technical Data
Diesel Generator SetExclusively from your Cat® dealer
Image shown may not reflect actual package
Perkins 1606A-E93TAG4™
3 Pole MCCB
617 (163.0)
)0.81(1.86)7.41(5.55
00810051
)6.91(1.47)9.51(1.06
LL5014J
300.0 kVA
240.0 kW
275.0 kW
343.8 kVA
275.0 kVA
220.0 kW
250.0 kW
312.5 kVA480V, 60 Hz
380-415V,50Hz
0.8
GEH300-1
PowerWizard 1.1+
Air Filter Type:
Combustion Air Flow:
m³/min (cfm) -Standby:
-Prime:
Max. Combustion Air Intake
Restriction: kPa (in H2O)
Radiator Cooling Air Flow:
m³/min (cfm)
External Restriction to
Cooling Air Flow: Pa (in H2O)
zH 06metsyS riA 50 Hz
Moment of Inertia: kg m² (lb. in²)
Governing Type:
Governing Class:
Compression Ratio:Displacement: l (cu.in)
Engine Electrical System:
-Voltage/Ground:
-Battery Charger Amps:
Weight: kg (lb) - Dry:
- Wet:
Cooling Method:
Bore/Stroke: mm (in)
Induction:
Manufacturer:
Model:
No. of Cylinders/Alignment:
Cycle:
-Prime:
-Standby:BMEP: kPa (psi)
-Prime:
-Standby:Gross Engine Power: kW (hp)Engine Speed: RPM
Oil Pan l (US gal):
Total Oil Capacity l (US gal):
Oil Filter Type:
Oil Type:
Cooling Method:
Prime
50 Hz
60 Hz
(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)
Recommended Fuel:
Fuel Consumption: l/hr (US gal/hr)
110%Load
75%Load
50%Load
100%Load
Fuel Filter Type:
Standby
50 Hz
60 Hz
Level: dB
Silencer System: kPa (in Hg)
Pressure Drop Across
Silencer Noise Reduction
Silencer Type:
Pressure: kPa (in. Hg)
Max. Allowable Back
-Prime:
m³/min (cfm) -Standby:
Exhaust Gas Flow:
-Prime:
-Standby:
Exhaust Gas Temperature: °C (°F)
Silencer Model & Quantity:
Cooling System Capacity:
l (US gal)
Water Pump Type:
Heat Rejected to Water &
Lube Oil: kW (Btu/min)
-Standby:
-Prime:
-Prime:
kW (Btu/min) -Standby:Heat Radiation to Room: Heat radiated from engine and alternator
Radiator Fan Load: kW (hp)
Cooling system designed to operate in ambient conditions up to 50°C (122°F). Contact your local OlympianTM dealer for power ratings at specific site conditions.
zH 06metsyS gnilooC 50 Hz
zH 06ecnamrofreP 50 Hz
Fuel System
Exhaust System
Lubrication systemPhysical Data
Engine Technical Data
60 Hz50 Hz
4.0 (16.1)
609.0 (21507)
Paper Element
23.4 (826)18.3 (648)
22.0 (778)17.9 (632)
4.0 (16.1)
125 (0.5)125 (0.5)
679.0 (23979)
1.95 (6657)
Water
Electronic
ISO 8528 G2
17.2:1
9.3 (567.5)
116.6 (4.6)/146.0 (5.7)
24/Negative
70827 (1823)
860 (1896)
Perkins
1606A-E93TAG46 / In Line
4 Stroke
Turbocharged Air To AirCharge Cooled
2130.0 (308.9) 2046.0 (296.7)
2238.0 (324.6)2318.0 (336.2)
287.0 (385.0)249.0 (334.0)271.0 (363.0) 314.0 (421.0)
18001500
Spin-On, Full Flow
36.0 (9.5)33.0 (8.7)
API CI-4
Water
31.2 (8.2)38.9 (10.3)53.3 (14.1)68.1 (18.0)74.1 (19.6)
43.3 (11.4)55.5 (14.7)60.1 (15.9)
Class A1/A2 Diesel or BSEN590Replaceable Element
33.4 (8.8)46.6 (12.3)60.1 (15.9)41.7 (11.0)57.7 (15.2)74.1 (19.6)
SD100 (1)
6.34 (1.872)4.22 (1.246)
11.616.1
10.0 (3.0)10.0 (3.0)
52.9 (1868)43.0 (1517)
50.6 (1789)39.1 (1379)
389 (732)436 (817)
354 (669)396 (745)
Industrial
123.0 (6995)
15.0 (20.1)
30.9 (8.2)30.9 (8.2)Centrifugal
145.0 (8246)
137.0 (7791)116.0 (6597)
43.1 (2451)30.5 (1735)
39.6 (2252)28.3 (1609)
10.0 (13.4)
Data ItemzH 06zH 05
Motor Starting Capability* kVA
Reactances: Per Unit
Xd
X'd
X''d
Reactances shown are applicable to prime ratings. *Based on 30% voltage dip at 0.6 power factor and SHUNT excitation system. ** With optional Permanent Magnet generator or AREP excitation.
Short Circuit Capacity** %
Manufactured for Olympian by:
Model:
No. of Bearings:
Insulation Class:
Winding Pitch - Code:
Wires:
Ingress Protection Rating:
Excitation System:
AVR Model:
OLYMPIAN Overspeed: RPM
Voltage Regulation: (steady state)
Wave Form NEMA = TIF:
Wave Form IEC = THF:
Total Harmonic Content LL/LN:
Radio Interference:
Radiant Heat: kW (Btu/min)
-50 Hz:
-60 Hz:
Supression is in line with European Standard EN61000-6
Physical Data Operating Data
Alternator Performance Data
Alternator Technical Data
623 585 536 - 682 458 - - 590
2.691 2.896 3.209 - 2.743 4.201 - - 3.264
0.123 0.133 0.147 - 0.125 0.192 - - 0.149
0.073 0.079 0.088 - 0.075 0.115 - - 0.089
415/240V 400/230V 380/220V 480/277V240/139V
V452/044V022/083220/127V
LL5014J
1
H
2/3 - 6
12
IP23
SHUNT
R250 20.1 (1143)
18.5 (1052)
4.0%
2.0%
50
+/- 0.5%
2250
300 300 300 300 300 300- --
kWkVAkWkVA
Technical Data
Voltage50 Hz Prime Standby
Standby RatingThese ratings are applicable for supplying continuous electricalpower (at variable load) in the event of a utility power failure. Nooverload is permitted on these ratings. The alternator on this modelis peak continuous rated (as defined in ISO 8528-3).
Prime RatingThese ratings are applicable for supplying continuous electricalpower (at variable load) in lieu of commercially purchased power.There is no limitation to the annual hours of operation and thismodel can supply 10% overload power for 1 hour in 12 hours.
Standard Reference ConditionsNote: Standard reference conditions 25°C (77°F) air inlet temp,100m (328ft) A.S.L. 30% relative humidity. Fuel consumption dataat full load with diesel fuel with specific gravity of 0.85 andconforming to BS2869: 1998, Class A2.
Definitions
kWkVAkWkVA
Voltage60 Hz Prime Standby
Weights & Dimensions
Weights: kg (lb)
Net (+ lube oil)
Wet (+ lube oil & coolant)
Fuel, lube oil & coolant
Dimensions: mm (in)
Height
Width
Length
DocumentsA full set of operation and maintenance manuals and circuit wiring diagrams.
Quality StandardsThe equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22.
WarrantyAll prime equipment carries a one year manufacturer's warranty.Standby equipment, limited to 500 running hours per year, has a two year manufacturer's warranty. For details on warranty cover please contact your local Dealer, or visit our website: www.OlympianPower.com.
General Data
Market: International
Information contained in this publication may be considered confidential.Discretion is recommended when distributing.
Materials and specifications are subject to change without notice.CAT, CATERPILLAR, their respective logos OLYMPIAN, "Caterpillar Yellow," the "Power Edge" trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
www.OlympianPower.com
© 2012 Caterpillar All rights reserved.
Note: General configuration not to be usedfor installation. See general dimensiondrawings for detail.
240.0300.0
240.0300.0
240.0300.0
220.0275.0
275.0 220.0
380/220V
415/240V
400/230V
220.0275.0
264.0330.0240.0300.0380/220V
275.0
275.0343.8250.0312.5480/277V
343.8250.0312.5220/127V
3008 (6631)
2483 (5474)
2452 (5406)
1848 (72.8)
1100 (43.3)
3300 (129.9)
240/139V
440/254V
275.0343.8250.0312.5
275.0343.8250.0312.5