Geant4 Medical Applications and Ion Physics

Toshiyuki Toshito (KEK/JST)

Feb. 12 2008@University of Tokyo 5th Geant4 Space User’s Workshop

Page 2: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Medical application

• Radiology– Diagnosis

• PET• Gamma camera

– Treatment for cancer• Radiotherapy

for example, GATE

Page 3: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Radiotherapy

• How to focus the dose?– IMRT :intensity modulated radiation therapy

• X-ray– Brachytherapy

• Encapsulated radio isotope (β-ray,γ-ray)– Particle therapy

• Proton, Ion

Page 4: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Cancer

• Cancer is the most common cause of death since 1981 in Japan. 31% in 2004

• About 40% of patients have a surgical operation. (National cancer center 2004)– Less than 10% of patients have a radiotherapy.

• New treatment techniques which improve treatment results and quality of life are desired.– radiotherapy, chemotherapy

Page 5: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Particle therapy100 Ref. http://www.nirs.go.jp/tiryo/himac/himac2.htm

protoncarbon

X-ray

γ-rayneutron

Rel

ativ

e D

ose

(%)

50

5.0 10.0 15.00.0Depth - Human Body (cm) 15

Amaldi and Kraft Rep.Prog.Phys.68 1861 (2005)

a few 100MeV/n 12C beam

BEVALAC (Berklay-US) 1975 - 1992 Ne, Si ~400 NIRS (Chiba-Japan) 1994 - 12C more than 3000GSI (German) 1997- 12CHIBMC (Hyogo-Japan) 2002 - 12C

carbon vs. X-ray

proton vs. Carbon

Bragg-peak

Page 6: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Particle therapy facilities in Japan

The Energy Research Center Wakasa Bay (Tsuruga: 200 MeV)

Hyogo Ion Beam Medical Center (HIBMC)

(Hyogo: 320 MeV/n)

Shizuoka Cancer Center(Mishima: 230 MeV)

NIRS(Chiba: 400MeV/n)

NCC East Hospital (Kashiwa: 235 MeV)

U. of Tsukuba PMRC (Tsukuba: 250 MeV)

Ion beamProton beam

Page 7: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Experiment Areas

Linac800 KeV/u

Linac6 MeV/u

Synchrotron800 MeV/u

Treatment Rooms

Ion Source

~65 m

HIMAC at NIRS (National Institute of Radiological Sciences)

Page 8: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

HIBMC in Hyogo

AcceleratorSynchrotron

proton(70-230MeV)Carbon-ions(70-320MeV/n)

Beam lines4 fixed-angle beam lines (proton & carbon)2 gantries for proton

Page 9: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

The Project

• “The Development of Software Framework for Simulation in Radiotherapy”– funded by the Core Research for Evolutional

Science and Technology (CREST) program organized by Japan Science and Technology Agency (JST) from 2003 to 2008

• Joint project among medical physicists, astro-physicists and Geant4 developers in Japan

Page 10: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Member Institutes• High Energy Accelerator Research Organization (KEK)• Ritsumeikan University (RITS)• Kobe University• Naruto University of Education • Toyama National College of Maritime Technology• Japan Aerospace Exploration Agency (JAXA)• National Institute of Radiological Science (NIRS)• National Cancer Center, Kashiwa• Gunma University Faculty of Medicine • Hyogo Ion Beam Medical Center (HIBMC)• Kitasato University

Page 11: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Goal of The Project

• Provide the software suit for simulation in radiotherapy, especially, particle therapy– Software framework and tools

• Implementation of geometry of facilities • DICOM interface• Visualization • GRID

– Tuned physics models• Validation of simulation results

– Collaboration with facilities

Page 12: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

EGS4JQMD

modeler

framework for medical application

others...

Scoring/Tally Package

Physics Listfor Radiotherapy

Knowledge DB

visualization/interactivity

DICOM interface

The system architecture

Geant4

Dose Calculation Engines

GRID Deployment

PTSsim

Page 13: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Use case and requirement sampling

• All of 6 facilities for particle therapy in Japan and one in Italy have been interviewed – NIRS– NCC-EAST– HIBMC– WERC– SCC– University of Tsukuba– INFN LNS at Catania, Italy

• Information on components in beam line and also treatment room have been gathered also

NCC-EAST (KashiwaHIBMC (Hyogo)

SCC (Shizuoka)

NIRS,HIMAC (Chiba)

PMRC (Tsukuba)WERC(Wakasa)

proton/heavy ionproton

Page 14: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Software framework for facility implementation

Page 15: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Basic design of Beam irradiation system

patient

Wobblermagnets

scatterer Dose monitors flatness monitor

Ridge filterRange shifter

MLC

RangeCompensator

beam

Purpose:Widen the beam size to fit the tumor size with keeping lateral flatness of beam fluxAdjust the depth of Bragg peak in a patient volume with the tumor position

Other technology:Double scattering, Spiral wobbling system for shortening the irradiation systemBeam scanning in three dimensions using small beam spot and variable beam energy

T.Aso IEEE NSS 2007 N60‐1

Page 16: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Directory structure of PTS simulator

PTSgeom/

sources/

G4Mmodules/

G4Mscoring/

HIBMCgantry/

NCCgantry/

IHIport/

demo/

data/ macros/

common/

material/

HIBMC/ NCC/

beam/

dicom/

monitor/

ridge/

scatter/

materials.macphys.mac

vis.mac

G4Mdicom/

UCSFETF/

common/ HIBMC/ NCC/

range.mac

bragg.mac

UCSF/ UCSF/

include/src/

PhysicsListetc.

• Applicable for multiple facilities• Geometrical information of

equipments can be given by text-file

• able to select physics models• easy to use, does not require C++

programming

Page 17: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Implemented irradiation systems using PTSsimFacility Accelerator Beam Energy

(MeV)Lateral Spreading System Range Modulator

HIBMCGantry

Synchrotron Proton150,190,230

Wobbler magnetsand scatter

Ridge filter

NCCGantry

Cyclotron Proton150,190,235

Scatter and double scatter Ridge filter

UCSF Cyclotron Proton67.5

N/A Propeller blades

HIMAC Synchrotron Carbon400 MeV/u

Wobbler magnets and scatter Ridge filter

HIBMC Synchrotron Carbon320 MeV/u

Wobbler magnets and scatter Ridge filter

GSI Synchrotron Carbon~400 MeV/u

Beam scanning Fine Ridge filter

T.Aso IEEE NSS 2007 N60‐1

Page 18: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Example of irradiation systemsScatter

Ridge filter Propeller blade

Ionization Chamber

Wire Chamber

Wobbler Magnets

Collimator

Multi-leaf collimator

Bolus

Water phantom

DICOM data

Double Scatter

/G4M/ChangeSystem NCCGantry

/G4M/System HIBMCGantry

/G4M/ChangeSystem UCSFSetup

T.Aso IEEE NSS 2007 N60

Page 19: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Others• Primary generator

– G4MBeamGun - HIBMC• Parallel beam with respect to

z-axis– Spot size

– G4MFocusGun - NCC• Cone beam with focusing

points– focusing points and

emittances of x and y direction

– G4GeneralParticleSource (GEANT4) - IHIport at NIRS

Focusing Point

GeneratingPoint

FocusGun

T.Aso IEEE NSS 2007 N60

Page 20: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

DICOM handling, visualization and UI

Page 21: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

DICOM (Digital Imaging and COmmunication in Medicine) interface

• DICOM handler had been developed independently – TOSHIBA, SIEMENS, and GE DICOM data had been

tested.– Filter modules are plugged in for converting original

CT data into a suitable format for making a geometry.• Extraction of patient geometry• Reformation of voxels• Density conversion

– DICOM-RT (Radiation Therapy)• HIBMC-Mitsubishi is tested

Load DICOM data

Compensation of lack slices

Select window of interest

Outline extraction

Reformation of voxles

Material creation

Geometry construction

Page 22: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

http://geant4.kek.jp/gMocren/

Calculated dose distributionCalculated dose distribution

color mapping

contour plot

Particle trajectoriesParticle trajectories

Opacity curve and color map editorOpacity curve and color map editor

free hand or templates with WW&WL editing

Supported system :- Windows 2k/XP or PC Linux OS- Pentium 4 or faster- more than 1 GB (recommend)

• no special hardware is necessary

Supported system :- Windows 2k/XP or PC Linux OS- Pentium 4 or faster- more than 1 GB (recommend)

• no special hardware is necessary

3D (ray casting) 2D (MPR)

Opacity curve and color map editor

gMocren and utility softwares are freely available.gMocren and utility softwares are

freely available.

Functionality Requirements Functionality Requirements ::

• To visualize- the modality image used by the simulation,- the calculated dose distribution and- the particle trajectories- in an agreeable speed

• Transfer function editor• Multi-platform (Windows, Linux)

• To visualize- the modality image used by the simulation,- the calculated dose distribution and- the particle trajectories- in an agreeable speed

• Transfer function editor• Multi-platform (Windows, Linux)

Trajectory information in the simulation is available.

gMocren : DICOM visualizergMocrengMocren : DICOM : DICOM visualizervisualizer

2/Nov/2007 22

IEEE NSS/MIC (San Diego, Nov/2006)

Page 23: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Physics validation

Page 24: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Lead Scatterer

0 0.5 1 1.5 2 2.5 30102030405060708090

散乱体厚 (mm)

陽子

線の

広が

り (m

m)

□ 150MeV 測定値■ 150MeV シミュレーション値△ 190MeV 測定値▲ 190MeV シミュレーション値○ 230MeV 測定値● 230MeV シミュレーション値

Nuclear Interaction Effect

MLC Water phantom

beam

50mm depth 250mm depth● : Measurements- : TPS calculations□ : G4 (histograms)

by T.Akagi (HIBMC)Bragg Peak

Spread Out Bragg Peak (SOBP)

( with Wobbler and Scatter )

(with Wobbler, Scatter, and Ridge filter)

Depth‐Dose distribution

Proton range

ーNIST PSTAR●Simulation

Material Properties

Wobbler Magnet

Uniform Irradiation Field

Edges of Multi-Leaf Collimator

Beam Delivery system validation

Wobbler demonstration:Spiral Wobbling

Stopping Power/Range , checked with NIST data 

― Simulation■ Measurement

Validation ActivitiesValidation ActivitiesValidation Activities for Protonsfor Protons

2/Nov/2007 24IEEE TNS V52,Issue4, (2005) 896pp

Page 25: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Fragmentation reactions• In the case of 400MeV/n (~30cm in water), only 30% of beams

can reach the region of bragg-peak; about 70% of beams are lost by fragmentation.

• Fragments having lower Z than carbon contribute to tail and lateral dose.

• Fragmentation reaction largely modulate dose distribution.• Knowledge of fragmentation reaction is important to calculate

dose distribution.

12C16O

B, Be, Li, He, H, nV~V(12C)

Validation ActivitiesValidation ActivitiesValidation Activities for  Carbonsfor  Carbons

Page 26: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

NIRS /IHI experimental beam lineNIRS /IHI experimental beam line

2/Nov/2007 26IEEE NSS/MIC (San Diego, Nov/2006)

Page 27: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Depth-dose in waterR

elat

ive

dose

Depth (mm)

Bragg peak

tail dose

320MeV/n 12CGeant4 Binary cascade

Rel

ativ

e do

se

Depth (mm)

Bragg peak

tail dose

320MeV/n 12CGeant4 Binary cascade

Dose by fragments

Page 28: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Dose by fragments

Bragg peak

Rel

ativ

e do

se

Depth (mm)

320MeV/n 12CGeant4 Binary cascade

C

BBe

Li

HeH

Bragg peak

Rel

ativ

e do

se

Depth (mm)

320MeV/n 12CGeant4 Binary cascade

Page 29: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Models for fragmentations in Geant4

• Binary cascade (G4BinaryLightIonReaction)• Wilson’s abrasion (G4WilsonAbrasionModel)• JQMD (JQMD2G4InelasticModel)

K. Niita et al., Phys. Rev. C 52 2620 (1995)T. Koi et al., CHEP03 ECONF C0303241 THMT005 (2003)

Cross section: Shen fomula(G4IonsShenCrossSection)-Nuclear Physics. A 49 1130 (1989)

Version 4.9.0

T.Toshito IEEE NSS/MIC 2007

Page 30: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Carbon-Watertotal charge-changing cross sections

BC

Wilson

JQMD

BC

Wilson

JQMD

Data (P152)GolovchenkoPRC66 014609 (2002)

SchallNIM B 117 221 (1996)

T.Toshito IEEE NSS/MIC 2007

Page 31: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Carbon-Waterpartial charge-changing cross sections

C->B C->Be

C->Li

BC

JQMD

WilsonBC

JQMDWilson

BCJQMD

Wilson

DataData

Data

C->B C->Be

C->Li

BC

JQMD

WilsonBC

JQMDWilson

BCJQMD

Wilson

T.Toshito IEEE NSS/MIC 2007

Page 32: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Angular distributions of H and He fragments in Carbon-Water int.

200-400MeV/n

H production He production

BC

JQMD

Wilson

BC

JQMD

WilsonData Data

BC

JQMD

Wilson

BC

JQMD

Wilson

H production He production

Preliminary

Preliminary

Important for lateral dose

T.Toshito IEEE NSS/MIC 2007

Page 33: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Carbon-Water8Be and 9B production cross sections

BC

JQMDWilson

BCJQMD

Wilson

C->8Be C->9BBC

JQMDWilson

BCJQMD

Wilson

C->8Be C->9B

Data

Data

Preliminary Preliminary

T.Toshito IEEE NSS/MIC 2007

Page 34: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Application at HIBMC

Page 35: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Beam profile• Comparison of beam profile

– Geant4.8.2.p01 and pencil beam algorithm used in therapy planning system at HIBMC

– 150 MeV proton, 2 cm range shifter, 0.16 cm scatterer, bolus, ridge filter designed for 10 cm SOBP and collimator

Page 36: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Comparison of dose profiles in water

• Geant4.8.2.p01• Pencil beam algorithm• Measurements in water

Page 37: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Beam profiles in the patient

• G4 in the patient (left)

• Pencil beam algorithm (right)

Page 38: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Functionality under development

Page 39: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

WNWNWN WNWNWN

WNWNWN WNWNWN WNWNWN

WNWNWN WNWNWN WNWNWN

WNWNWN WNWNWN WNWNWN

WNWNWN WNWNWN WNWNWN

WNWNWN WNWNWN WNWNWN

WNWNWN

WMSWMSWMS WMSWMSWMS WMSWMSWMS

GlobusGlobus I/FI/F GlobusGlobus I/FI/FGlobusGlobus I/FI/F

Job SubmissionJob Submission

MatchMakerMatchMatchMakerMaker

InformationSupermarketInformationInformationSupermarketSupermarket

Task QueueTask QueueTask Queue

Network ServerNetwork ServerNetwork Server

Resource BrokerResource BrokerResource Broker

Grid Web UIGrid Web UIGrid Web UI

SESESE SESESE SESESE

Grid access via HTTPJob submission, management, monitoringGet and browse results 

Grid access via HTTPGrid access via HTTPJob submission, management, monitoringJob submission, management, monitoringGet and browse results Get and browse results 

Resource BrokerInquiry resource informationJob queuing and logging 

Resource BrokerResource BrokerInquiry resource informationInquiry resource informationJob queuing and logging Job queuing and logging 

File CatalogueIndependent of physical location of filesReplication and transfer automatically

File CatalogueFile CatalogueIndependent of physical location of filesIndependent of physical location of filesReplication and transfer automaticallyReplication and transfer automatically

Virtual OrganizationBased on GSIAcross the institutes 

Virtual OrganizationVirtual OrganizationBased on GSIBased on GSIAcross the institutes Across the institutes 

Site‐ASiteSite‐‐AA Site‐BSiteSite‐‐BB Site‐CSiteSite‐‐CC

GRID: distributed computig over the InternetGRID: distributed GRID: distributed computigcomputig over the Internetover the Internet

2/Nov/2007 39外部評価委員会

IEEE NSS/MIC (Puerto Rico, Oct/2005)

Page 40: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Application to educationApplication to education

40

• 1.198 MeV gammas entering 3.004 cm of water• 40 events are displayed to “measure” the probability of the through gammas

Examples of Virtual Laboratory

Virtual Lab on WebWeb Textbook

2/Nov/2007

Page 41: Geant4 Medical Applications and Ion Physics€¦ · Geant4 Dose Calculation Engines GRID Deployment PTSsim. Use case and requirement sampling • All of 6 facilities for particle

Summary

• Geant4 is extensively applied to radiology because of its capability to handle all particles including ions, complex geometry and electromagnetic fields and flexibility.

• The software suit for simulating radiotherapy has been developed in the CREST project “The Development of Software Framework for Simulation in Radiotherapy”.