ENCLOSURE 3 MFN 06-089 GE Report, GE-NE-0000-0041-0403-R1-NP, Revision 1, First Energy Corp, Perry Nuclear Power Plant, 12/23/04 Instability Event, OPRMPerformance Evaluation, March 2006 Non-Proprietary Version IMPORTANT NOTICE This is a non-proprietary version of GE-NE-0000-0041-0403-R1-P, which has the proprietary information removed. Portions of the enclosure that have been removed are indicated by an open and closed bracket as shown here [[ ]]

GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

ENCLOSURE 3

MFN 06-089

GE Report, GE-NE-0000-0041-0403-R1-NP, Revision 1, FirstEnergy Corp, Perry Nuclear Power Plant, 12/23/04 Instability

Event, OPRMPerformance Evaluation, March 2006

Non-Proprietary Version

IMPORTANT NOTICE

This is a non-proprietary version of GE-NE-0000-0041-0403-R1-P, which has the proprietaryinformation removed. Portions of the enclosure that have been removed are indicated by an openand closed bracket as shown here [[ ]]

Page 2: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE Energy, Nuclear1989 Little Orchard Road

San Jose, CA 95125

GE-NE-0000-004 1-0403-RI-NPRevision 1

Class IDRF 0000-0051-4286

March 2006

NON-PROPRIETARY VERSION

FIRSTENERGY CORP

PERRY NUCLEAR POWER PLANT

12/23/04 INSTABILITY EVENT

OPRM PERFORMANCE EVALUATIONIC=

1-JI JjN . -I

Page 3: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-41-0403-Ri -NPNon-Proprietary Version

NON-PROPRIETARY INFORMATION NOTICE

This is a non-proprietary version of the document GE-NE-0000-0041-0403-R1-P, whichhas the proprietary information removed. Portions of the document that have beenremoved are indicated by an open and closed double brackets as shown here [[ ]].

IMPORTANT NOTICE REGARDINGCONTENTS OF THIS REPORT

Please Read Carefully

The only undertakings of the General Electric Company (GE) respecting information inthis document are contained in the contract between the customer and GE. Nothingcontained in this document shall be construed as changing the contract. The use of thisinformation by anyone other than the customer, or for any purpose other than that forwhich it is intended, is not authorized. With respect to any unauthorized use, GE makesno representation or warranty, express or implied, and assumes no liability as to thecompleteness, accuracy, or usefulness of the information contained in this document, orthat its use may infringe privately owned rights.

ii

Page 4: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-00004 1-0403-RI -NPNon-Proprietary Version

Table of Contents1. BACKGROUND ............................................... 12. ASSESSMENT OBJECTIVES ................................................ 23. SYSTEM DESIGN AND KEY INPUTS ................................................ 34. EVALUATION AND RESULTS ............................................... 4

4.1 Oscillation Mode Determination ................................................ 44.2 PBDA Cutoff and Averaging Filter ................................................ 44.3 Pre-Trip Alarms ............................................... 54.4 Leading OPRM Cells and Detection Algorithm Performance ..................................... 54.5 Oscillation Period and Period Tolerance ................................................ 6

5. CONCLUSIONS ............................................... 76. REFERENCES ............................................... 8

Hii

Page 5: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-000041 -0403-RI -NPNon-Proprietary Version

1. BACKGROUND

Perry has implemented Boiling Water Reactor Owners Group (BWROG) Long TermStability Solution Option III, which is described in Reference 1. Reload evaluation of theOPRM system setpoints has been performed in accordance with Reference 3 and the Perry-specific OPRM system setpoints are established.

The OPRM system monitors core thermal-hydraulic instabilities by real-time interrogationof OPRM cells, which are composed of closely packed LPRM detectors. The OPRM cellsignals are analyzed by three separate detection algorithms that test for neutron fluxoscillations. These algorithms are the Period Based Detection Algorithm (PBDA), theAmplitude Based Algorithm (ABA), and the Growth Rate Algorithm (GRA). Automaticprotection is actuated if any one of the three algorithms meets its trip conditions.However, only the PBDA is required to provide protection of the Safety Limit MinimumCritical Power Ratio (SLMCPR) for anticipated reactor instabilities. The other twoalgorithms are included as defense-in-depth.

A December 23rd 2004 plant transient included unplanned recirculation pump transfer fromfast to slow speed resulting in a power decrease from about 100% to 44% rated and a flowdecrease from about 99% to 33% rated. As the feedwater temperature was reduced toequilibrium conditions, the power increased from about 44% to about 55% with littlechange in flow. The state condition just prior to the instability was in the upper left cornerof the power/flow map, which may be susceptible to coupled thermal-hydraulic neutronicoscillations. Subsequently, an OPRM initiated scram occurred after the thermal-hydraulicinstability (THI) event developed (see Figure 1).

The Perry core loading consists of 584 bundles of GE14 and 164 bundles of GE12, bothbundles with a 10x10 fuel design. Perry is licensed to operate within the MaximumExtended Load Line Limit Analysis (MELLLA) domain.

1

Page 6: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-41 -0403-RI -NPNon-Proprietary Version

2. ASSESSMENT OBJECTIVES

The objectives of the Perry 12/23/04 THI event evaluation are to:

* Assess the functionality of the second-order Butterworth averaging and filteringalgorithms

* Analyze selected OPRM cells

* Determine the characteristics of the reactor instability event (e.g., oscillation mode,oscillation frequency, period counts, oscillation amplitude)

* Determine the algorithm that initiated the trip --- PBDA, ABA or GRA

* Assess the adequacy of the as-designed OPRM functions - alarm history, trip timing,PBDA Successive Confirmation Count (SCC) setpoint, OPRM cell signal amplitudesetpoint

* Provide selected plots of OPRM cells SCC, Relative Signal (RS), and OscillationPeriod (OP).

2

Page 7: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-41-0403-RI -NPNon-Proprietary Version

3. SYSTEM DESIGN AND KEY INPUTS

The Perry OPRM system uses a 4BL configuration with 4 LPRMs assigned to each OPRMcell. Figures 2a through 2d illustrate the LPRM to OPRM assignment for the fourchannels, with 32 OPRM cells per channel for Channels 1 and 2, and 29 OPRM cells perchannel for Channels 3 and 4. In this report, OPRM cells are designated as xyy,corresponding to OPRM cell yy of Channel x. Table 1 lists key parameters used by theOPRM system prior to the reactor trip and its assigned values.

The amplitude trip setpoint is the relative power level, or peak over average (P/A), atwhich the OPRM cell generates a trip signal, provided the required number of SCC hasbeen reached. Two conditions must be met for the same OPRM cell in an OPRM channelto result in a PBDA-based channel trip:

1. The SCC reaches or exceeds the SCC setpoint (10 for Perry).

2. The cell signal P/A reaches or exceeds the OPRM trip amplitude setpoint (1.07 forPerry).

The OPRM performance evaluation consists of post-event analysis of the OPRM data fromthe plant computer. About 910 seconds of LPRM and OPRM data was collected. TheOPRM data includes the following information, available for all OPRM cells:

* Relative signal

* SCC

* Time-averaged base period.

Both the LPRM and OPRM data was available during the period, which provided usefuldata for thermal-hydraulic instability (THI) event off-line evaluation.

3

Page 8: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-4 1-0403-RI -NPNon-Proprietary Version

4. EVALUATION AND RESULTS

The OPRM performance evaluation includes identification of:

* Oscillation mode - core-wide or regional

* PBDA cutoff and averaging filter

* Pre-trip alarms

* Leading OPRM Cells and detection algorithm performance

* Period Tolerance and Oscillation period

4.1 Oscillation Mode Determination

The relative signals for four selected OPRM cells from each core quadrant from Channel 1are shown in Figure 3. For these nearly symmetric four OPRM cells (Cells 106, 109, 124and 127), the oscillations are all in phase, indicating that the oscillations are in thefundamental core-wide mode.

4.2 PBDA Cutoff and Averaging Filter

Based on the LPRM data provided, the LPRM signals for a few selected OPRM cells wereexamined.

Both the averaging filter and cutoff frequency employ the same second-order Butterworthfilter with different frequency (]Q) values. The cutoff frequency is set at 1Hz. The averaging

4

Page 9: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-00004 1-0403-RI-NPNon-Proprietary Version

filter is implemented with a frequency corresponding to an average time constant of 5seconds.

[[

The use of a 5 second averaging time constant resulted in a relatively flat OPRM cellaverage signal and was adequate for this event since the growth rate was relatively low(growth rate < 1.10).

1]]

]]

The second-order Butterworth filter with a setting of 1Hz cutoff frequency is found to bevery effective in removing residual high-frequency noise from the oscillation signal.

4.3 Pre-Trip Alarms

Based on individual SCC plots, there were a few alarms during the event. There wereseveral occasions when the SCC exceeded the alarm count of 20 while the P/A signalremained below 1.07. Figures 6a through 6c show a few cells that might have generatedpre-trip alarms, which are consistent with the several alarms observed at the plant.

4.4 Leading OPRM Cells and Detection Algorithm Performance

Table 2 lists the maximum SCC from the recorded data for all OPRM cells in Channels 1and 3. Many cells were found to have exceeded the SCC threshold of 10 when the OPRMsystem tripped. The OPRM P/A signal was at about 1.070 for the leading OPRM cellswhen the RPS trip was actuated. (One leading OPRM cell in Channel 1 is Cell 120.)Hence, the system worked as designed.

Figures 7a through 7c show three typical leading OPRM cells. These cells reached theSCC setpoint prior to reaching the OPRM trip amplitude setpoint. This is the expectedsequence of instability detection and suppression for Option III.

5

Page 10: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-4 1-0403-RI -NPNon-Proprietary Version

The general observation is that most of the OPRM cells were participating in the instabilityand approaching the OPRM trip setpoint around the same time. As the oscillationmagnitude grew it overcame the interference from the noise and allowed fewer resets. Infact, there were very few resets in the counts once the oscillations were coherent in nature.

The other two defense-in-depth algorithms (ABA and GRA) did not generate a trip signalsince the relative amplitude did not reach the 1.1 threshold. It is concluded therefore, thatthe OPRM system trip was generated by the PBDA algorithm and that the OPRM systemprovided its intended protection.

4.5 Oscillation Period and Period Tolerance

]]Based on the this THI event data, the use of a 100 msec period tolerance did not result inspurious resets and the setting is appropriate for the THI protection.

The core-wide mode reactor oscillations were initiated approximately 200 seconds prior tothe reactor trip. At the instability threshold, the oscillation period tended to be lesscoherent. [[

]]

6

Page 11: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-00004 1-0403-Ri -NPNon-Proprietary Version

5. CONCLUSIONS

The following conclusions can be drawn from the Perry OPRM instability event dataanalysis:

1. The oscillation mode is core-wide.

2. The reactor was tripped by the PBDA. The OPRM P/A was exactly at the cycle-specific amplitude setpoint of 1.07 when the trip occurred and the PBDA tripped asexpected.

3. The Tmin and Tmax settings of 1.2 and 3.5 seconds, respectively, were appropriatefor the specific Perry configuration.

4. The use of a 5 second time constant averaging filter was adequate for this event.

5. Selection of 1 Hz frequency for the condition filter cutoff is sufficient to removehigh frequency noise from the OPRM cell signal to minimize SCC resets for acoherent oscillation.

6. Based on the MCPR assessment in the previous ODYSY report, the OPRM systemSCC and amplitude setpoints were adequate for safety limit MCPR protection.

7. The design of 4 LPRMs per OPRM cell was adequate for this application since theOPRM cell signals did not exhibit any abnormal behavior.

8. Selection of the period tolerance at 100 msec or larger was sufficient to avoid SCCresets due to normal signal period variations, filtering residual effects that maydistort the signal characteristic at peaks/valleys, and software digital processinginaccuracies.

The PBDA performed as expected since the OPRM P/A was at the amplitude trip setpointwhen the reactor scram was initiated. Most of the OPRM cells performed as expected,exhibiting very few SCC resets. The Perry THI event did not produce any safety hazardand the SLMCPR was protected by the Option III OPRM system.

The lessons learned from the NMP2 THI event provided effective settings in this THIevent and the OPRM system functioned and generated a trip signal as designed.

7

Page 12: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-41-0403-Ri-NPNon-Proprietary Version

6. REFERENCES

1. NEDO-3 1960-A, "BWR Owner's Group Long-Term Stability Solutions LicensingMethodology," November 1995.

2. Not Used.

3. NEDO-32465-A, "Reactor Stability Detect and Suppress Solutions Licensing BasisMethodology for Reload Application," August 1996.

4. Not Used.

5. Not Used.

6. Not Used.

8

Page 13: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-4 1-0403-Ri -NPNon-Proprietary Version

Table 1. OPRM System Settings

Parameter Setting

Corner or cutoff 1 Hzfrequency

Period tolerance 100 msec

OPRM P/A setpoint 1.07

OPRM CC alarm setpoint 20

OPRM CC trip setpoint 10

Tmin (Minimum 1.2oscillation period check)

Tmax (Maximum 3.5oscillation period check)

OPRM trip enabled > 23.8% rated power,region size < 60% rated flow

Min LPRMs per 1Operable OPRM cell

Averaging filter time 5 secondsconstant

Reactor Protection One of two, taken twiceSystem (RPS) trip logic

9

Page 14: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-41-0403-RI -NP

Non-Proprietary Version

Table 2. Maximum SCC for Selected OPRM channels

OPRM Cell Channel 1 Channel 3

1 32 272 36 333 43 3**4 33 305 22 446 36 337 36 428 33 409 _ _34 33

10 33 4311 38 5312 35 4213 32 3314 38 3315 33 4116 48 4317 28 3118 35 3119 56 2820 49 3321 45 3322 26 3323 35 3524 36 3525 51 2926 40 2427 24 3728 29 3029 30 4030 26 N/A31 32 N/A32 28 N/A

** Might be defective. The base period was nevstays as 5.5 seconds throughout the THI event.

er reset after the runback. It

10

Page 15: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-4 1-0403-RI -NPNon-Proprietary Version

Figure 1. Event Power/Flow Path

Two Loop Power- Flow Map

U.

i

III10

70-

45 - - - -

Q ,...,.. -.--- ----- ~ ------

35

LK

Is _- - - -

IO-A"ci 5 10 15 Z3 ZS 30 4046 SO ID E 65

COREFLOW%rotd

70l 75 Ea 85 SO 1130 1135 Ila.

11

Page 16: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-41-0403-RI -NPNon-Proprietary Version

Figure 2a. Perry OPRM Channel 1 Assignment

12

Page 17: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-41 -0403-RI -NPNon-Proprietary Version

Figure 2b. Perry OPRM Channel 2 Assignment

13

Page 18: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

Al - - -

GE-NE-0000-41-0403-RI -NPNon-Proprietary Version

Figure 2c. Perry OPRM Channel 3 Assignment

14

Page 19: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-41 -0403-RI -NPNon-Proprietary Version

Figure 2d. Perry OPRM Channel 4 Assignment

15

Page 20: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-41-0403-RI -NPNon-Proprietary Version

Figure 3. Core-Wide Mode Demonstration

Core-Wide Oscillation

2.3 -

2.2 -. *

2.1 . . ii *I t ; II I i ioil :Cell 109

2 - II~~ lX 2 . i , -Cell 124

1.9 - ! I , , .8 i-iCell 106

1.8- , h v v . I Iv. 'v T

a 1.7-0

1.6 , ,860 870 880 890 900

Time (seconds)

16

Page 21: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-000041 -0403-RI -NP

Non-Proprietary Version

Figure 4 Cell 105 LPRM and OPRM Signals (1 Hz Cutoff)

11

1]

17

Page 22: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-4 1-0403-RI -NPNon-Proprietary Version

Figure 5a. Cell 105 OPRM Signals (4 Cutoff Frequencies)

[I

]]

18

Page 23: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-000041-0403-R1 -NPNon-Proprietary Version

Figure 5b. Cell 105 OPRM Signal (1.0 and 1.5 Hz Cutoff frequency)

1[

]]

19

Page 24: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-4 1-0403-Ri -NPNon-Proprietary Version

Figure 6a. Pre-Trip Alarm (Cell 119)

OPRM Cell 119_ RS

A OP(seconds)0 Counts

I-, 60

IL00

a)tw

2.00000 -&-1.80000-

1.60000 M

1.40000-_

1.20000 -

1.00000 -

0.80000 E

0.60000 -

0.40000 -

0.20000 -

0.00000 X

600

50

40

30=010

20

10

0700 800 900

Time (s)

20

Page 25: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-41-0403-RI -NP

Non-Proprietary Version

Figure 6b. Pre-Trip Alarm (Cell 115)

OPRM Cell 115

2.00000 40

1.80000 36

1.60000W 32

1.40000 - - 28

n 1.20000 24 RS0o 1.00000 Wwfi~W' P 20 a Period

i 0.80000 i I 0 Counts

0.60000 - 12

0.40000 - 8

0.20000 4

0.00000 0700 750 800 850 900

Time (s)

21

Page 26: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-41-0403-RI -NPNon-Proprietary Version

Figure 6c. Pre-Trip Alarm (Cell 128)

22

Page 27: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-4 1 -0403-RI -NPNon-Proprietary Version

Figure 7a. One Leading Cell Performance (Cell 120)

OPRM Cell 120

0L00a,wo

2.00000 -

1.80000 '

1.60000 - - Al

1.40000 -

1.20000 -

1.00000 ;_ :--

0.80000 -

0.60000 - i

0.40000

0.20000 - -

0.00000 *850 860 870 880

' 40

- -36

-32

-28

24

/ 2016

- I 12

-4

0890 900 910

c -RS3 A Period0

o) Counts

Time (s)

23

Page 28: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-0000-41-0403-RI -NPNon-Proprietary Version

Figure 7b. One Leading Cell Performance (Cell 131)

OPRM Cell 131

2.80000C

1.2000C

1.6000C

m .2000C

0.6000C

2 . 0_ = 0 0 C -. 40

DN--- _- 32

D. -0eC--28

D ~f - 24 ., R

DAA 1.0A 20 n Period

D < _12

D -_ 8

850 860 870 880 890 900 910

Time (s)

24

Page 29: GE Report, GE-NE-0000-0041-0403-RI-NP, Revision 1, 'First ... · Class I DRF 0000-0051-4286 March 2006 NON-PROPRIETARY VERSION FIRSTENERGY CORP ... that its use may infringe privately

GE-NE-00004 1-0403-Ri-NPNon-Proprietary Version

Figure 7c. Leading Cell Performance (Cell 102)

OPRM Cell 102

2.00000 - 40

1.80000 -- ~ %_ - 36

1.60000 -A 32

1.40000 - 28

eL 1.20000 24 -RS

0 1.00000 _ .V ; 20 0 E Period0 0

W. 0.80000 - 16 U Counts

0.60000 - 12

0.40000 - 8

0.20000 4

0.00000 0850 860 870 880 890 900 910

Timre (s)

25