39
The LOGIQ 200 PRO Series

GE Logiq 200 Pro Training

Embed Size (px)

Citation preview

  • The LOGIQ 200 PRO Series

  • LOGIQ 200 PRO SeriesThe PRO Series represents outstanding value for the most discerning professional, delivering increased productivity and superior diagnostic outcomes for you and your patients.ProgressProfessionalProductivityProductivityInvestment ProtectionImage Quality

  • RELAYSCANNERINTERFACE CON 1USC BUS-SHV+SHVSCAN Board CON 2

  • TX DRVP GUN ASSYWATCH DOGINTERFACEPRE AMP\

    CROSSPOINTUSC BUSNOVA BUS+THV-THVTBFPGC

  • ACC GENAAFTGCADCCOSMODDSIICUSC BUSNOVA BUSTO MVPPGCRBF

  • Digital Beamformer Catch Axial, Lateral, and TemporalResolution.

  • Digital BeamformerAuto Wave ShapingAxial ResolutionLateral ResolutionContrast ResolutionTemporal ResolutionBest B-Mode IQ!Wide Aperture Technology40MHz Converter3CB(2-5MHz Probe)Flicker-freeMonitorHigh Precision Digital Beamformer

    ATO

  • ATOAcoustic DataLOGIQ200MD PROImage ProcessorImageAnalysisImageOptimization based on Digital Adaptive ProcessingATO gives you the bestcontrast resolutionusing One-Touch on keyboard

  • ATOATOIn secondsLess Operator Dependent Faster... Better Image QualityConventional Manual Image Optimization2-5 MinutesROI

  • SAPIMAGE SOFTENERFRAME AVERAGEB/M FRONTEND CONTROLPEAKHOLDALMITPXYMEMORYCRDTFZOOMERXY ADDRGENNON-INTCONVERTCINECONTROLCINE MEMORYFIFOXYMEMORYDSPPROGRAMMEMORYUSC BUSI/FIMAGESTORAGERAMIMAGEDISPLAYCONTROLVIDEOLUTVideoDAC

    INTERLACECONVERTVIDDACVIDEODECODERSYNCGENERATOR

    NOVA BUSUSC BUSMVP Board

  • ROMRAMRESETCPURTCSUPERI/OIDECTLVRAMAGDCFROM NOVA BUSMSTE

  • HV +/-100V+/- 65 V

  • LV Voltages From System

  • Password : Antony

  • COMPARISION OF LOGIC 200 WITH 200 PRO

    Logic 200 AlphaLogic 200 ProMSTMSTDSCMVPESPRBFRTCTBFCONNSCANHV unitBPHV UNITMONITORNon Interlace Monitor

  • Follow these steps to enter the Service Menu.NoteProbes should be installed in the port and Blue Shift key should be off before take these steps.1. Pressing Shift + Ctrl keys and then press the Shift +s keys, and then Shift + 1 keys.2. Input the PASSWORD and press Return key.The Service Top Menu will appear on the monitor as shown in ILLUSTRATION 2--5.Service Utility MENU : Top Menu 99/03/12 09:16:37Current Software Version is 3.0*System DiagnosisBoard/Program VersionSystem ResetKey Operation HistoryOption SetInitialize :1 (1:America 2:Europe 3:Asia 4:Japan)System Clock AdjustExit

  • TEST Conditions

  • Follow these steps to exit the Service Menu.1. Press Shift + R keys. If this step will be performed again, the Service Menu will be entered again.OR2. Select Exit on the Top Menu, and press Set or Return keys.The Service Menu will be exited.

    Follow these steps to operate the Service Menu.1. Using Arrow Up/down keys, select one of seven items.2. Press Set or Return keys.The Service Sub Menu will be appeared or Service Menu will be operated.NoteResetting the system using the System Reset, to reboot System, does not affect on the systempresets.

  • Follow these steps to enter the System Diagnosis menu.1. Using the Arrow up/down keys, select the System Diagnosismenu in the Top Menu. Refer to the ILLUSTRATION 2--5. The left side of selected menu, here will be appeared the cursor (*).2. Press Set or Return keys.The System Diagnosis menu will appear on the monitor as shown in the ILLUSTRATION 2--6.Service Utility MENU : System Diagnosis 99/03/12 09:16:37Current Software Version is 3.0NAME Time Status*System test 21 MScan Test 0 MTBF Test 0 MLinear/Convex Path 0 MSector Probe Path 0 MBPHV test 1 MMVP Hardware Test 1 MB mode Function 1 MB mode Cine 8 MM mode Function 2 MMSTE test 4 MKeyboard 0 MPIOP 1 MMonitor 0 MPower Supply 1 MExitPress ctrl+Xto

  • Failure Codes

  • CAE Convex Probe

    -Frequency:5Mhz -Bandwidth: 3.7- 7.4 Mhz -FOV:72deg -Convex ROC:72mmR -Biopsy guide: AvailableCBF Convex Probe

    - Frequency:3.5Mhz - Bandwidth: 2.5 - 5.0 Mhz -FOV:72deg -Convex ROC:50mmR -Biopsy guide: AvailableLB Linear Probe

    -Frequency:3.5Mhz -Bandwidth: 2.5 - 5.0 Mhz -FOV:94mm

    LE Linear Probe

    -Frequency:5.0Mhz -Bandwidth: 3.7 -7.4 Mhz -FOV:83mm

    LD Linear Probe

    -Frequency:3.5Mhz -Banswidth: 2.5 -5.0 Mhz -FOV:94mm

    MTZ Micro-Convex Probe

    -Frequency:6.5Mhz -Bandwidth: 4.3 -8.6 Mhz -FOV:124deg -Convex ROC:10mmR -Biopsy guide:Available

    Wide Range of Probes

  • Wide Range of Probes

  • ERB Micro convex/Linear Array probe-Frequency : 7.0Mh-Bandwidth : 5.2-11.3Mhz-FOV : 12 deg10L Linear probe-Frequency : 9.0Mhz-Bandwidth : 5.2-11.3Mhz-FOV : 40mmS317 Phased Array Sector probe-Frequency : 3.5Mhz-Bandwidth : 2.5-5.0Mhz-FOV : 90 deg3Cb Convex Array Probe-Frequency : 3.5Mhz-Bandwidth : 2.5-5.0Mhz-FOV : 59 degCS Microconvex Array probe-Frequency : 3.5Mhz-Bandwidth : 2.7-4.2Mhz-FOV : 81 degWide Range of Probes