2
FEATURES Double-wound helical coil design Minimizes cooling water needs Wide variety of exotic alloys for corrosion resistance Retained shellside gasket reduces reassembly time Formed shell eliminates top shell flange weld interfaces Mounting bracket can be installed without removing flange bolts SENTRY TLR SINGLE HELICAL TUBE Sample Coolers SAMPLE CONDITIONING Gas Liquid & Slurry Solid & Powder Steam & Water The Sentry® TLR sample cooler/heat exchanger cools a sample from a process stream. It may seem simple, but it is a uniquely designed small tube and shell heat exchanger. The sample to be cooled flows through the tube side of the cooler, and the cooling fluid flows through the shell side. The cooled sample then is taken to a laboratory for analysis or piped to in-line process instrumentation for continuous monitoring of properties such as conductivity, pH or other chemical constituents. MODELS TLR-4225 | TLR-4225U | TLR-42B5 | TLR-42B5U | TLR-4BB5 BENEFITS The Sentry TLR sample cooler is the most efficient and cost-effective sample cooler available. Offers optimal service for flows below 1800 cc per minute for single phase and below 1000 cc per minute for condensing heat transfer. The Sentry TLR sample cooler is optimized for steam condensing service. 5 10 15 20 25 Approach Temperature ( o C) 60 50 40 30 20 10 0 Pressure Drop (PSI) 1 PSI = 0.069 Bar 0 10 20 30 40 50 Approach Temperature ( o F) 400 600 800 1000 1200 1400 1600 1800 2000 CCM 0.1 0.2 0.3 0.4 0.5 GPM 60 80 100 120 140 160 180 200 220 240 260 280 Lbm/Hr Model TL -4225 Surface Area 2.4 Ft. 2 [0.22 m 2 ] 5 GPM [18.9 L/min] Cooling Water at 95 o F [35 o C] 5 PSI [0.35 Bar] Pressure Drop Sample Pressure Drop (PSI) Flow Rate 600 o F (316 o C) 500 o F (260 o C) 400 o F (204 o C) 300 o F (149 o C) 200 o F (93 o C) Inlet Temp. 150 o F (66 o C) 700 o F (371 o C) R PERFORMANCE CURVE - WATER 5 10 15 Approach Temperature ( o C) 0 10 20 30 Approach Temperature ( o F) 400 600 800 1000 1200 CCM 0.1 0.2 0.3 GPM 40 50 60 70 80 90 100 110 120 130 140 150 160 170 Lbm/Hr Model TL -4225 Surface Area 2.4 Ft. 2 [0.22 m 2 ] 7 GPM [26.5 L/min] Cooling Water at 95 o F [35 o C] 9.5 PSI [0.66 Bar] Pressure Drop Flow Rate 500 PSIA [34.5 bar(a)] 1000 PSIA [68.9 bar(a)] 1500 PSIA [103.4 bar(a)] 2000 PSIA [137.9 bar(a)] 2500 PSIA [172.4 bar(a)] 3100 PSIA [213.7 bar(a)] Saturated Steam Inlet Pressure R PERFORMANCE CURVE - STEAM

Gas SENTRY TLR SINGLE HELICAL TUBE Liquid & Slurry …

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Gas SENTRY TLR SINGLE HELICAL TUBE Liquid & Slurry …

FEATURES�� Double-wound helical coil design

�� Minimizes cooling water needs

�� Wide variety of exotic alloys forcorrosion resistance

�� Retained shellside gasket reducesreassembly time

�� Formed shell eliminates top shellflange weld interfaces

�� Mounting bracket can be installedwithout removing flange bolts

SENTRY TLR SINGLE HELICAL TUBE Sample Coolers

S A M P L E CO N D I T I O N I N G

Gas

Liquid & Slurry

Solid & Powder

Steam & Water

The Sentry® TLR sample cooler/heat exchanger cools a sample from a process stream. It may seem simple, but it is a uniquely designed small tube and shell heat exchanger. The sample to be cooled flows through the tube side of the cooler, and the cooling fluid flows through the shell side. The cooled sample then is taken to a laboratory for analysis or piped to in-line process instrumentation for continuous monitoring of properties such as conductivity, pH or other chemical constituents.

MODELS

TLR-4225 | TLR-4225U | TLR-42B5 | TLR-42B5U | TLR-4BB5

BENEFITS

The Sentry TLR sample cooler is the most efficient and cost-effective sample cooler available. Offers optimal service for flows below 1800 cc per minute for single phase and below 1000 cc per minute for condensing heat transfer. The Sentry TLR sample cooler is optimized for steam condensing service.

5

10

15

20

25

App

roac

h Te

mpe

ratu

re (o

C)

60

50

40

30

20

10

0

Pres

sure

Dro

p (P

SI)

1 PS

I = 0

.069

Bar

0

10

20

30

40

50

App

roac

h Te

mpe

ratu

re (o

F)

400 600 800 1000 1200 1400 1600 1800 2000CCM

0.1 0.2 0.3 0.4 0.5GPM

60 80 100 120 140 160 180 200 220 240 260 280Lbm/Hr

Model TL -4225 Surface Area 2.4 Ft.2 [0.22 m2]

5 GPM [18.9 L/min] Cooling Water at 95oF [35oC]5 PSI [0.35 Bar] Pressure Drop

Sample Pressure Drop (PSI)

Flow Rate

600o F (3

16o C)

500o F (260o C)

400o F (204o C)

300o F (149o C)

200oF (93oC)

Inlet Temp. 150oF (66oC)

700

o F (3

71o C)

R

PERFORMANCE CURVE - WATER

5

10

15

App

roac

h Te

mpe

ratu

re (o

C)

0

10

20

30

App

roac

h Te

mpe

ratu

re (o

F)

400 600 800 1000 1200CCM

0.1 0.2 0.3GPM

40 50 60 70 80 90 100 110 120 130 140 150 160 170Lbm/Hr

Model TL -4225 Surface Area 2.4 Ft.2 [0.22 m2]

7 GPM [26.5 L/min] Cooling Water at 95oF [35oC]9.5 PSI [0.66 Bar] Pressure Drop

Flow Rate

500

PSIA

[34.

5 ba

r(a)

]

1000

PSI

A [6

8.9

bar(a

)]

1500

PSI

A [103

.4 ba

r(a)]

2000

PSIA

[137

.9 ba

r(a)]

2500

PSIA [1

72.4

bar(a)]

3100 PSIA [213.7 bar(a

)]

Satu

rate

d St

eam

Inle

t Pre

ssur

e

R

PERFORMANCE CURVE - STEAM

Page 2: Gas SENTRY TLR SINGLE HELICAL TUBE Liquid & Slurry …

SPECIFICATIONSmodels shell design tube design tube material shell material area shipping weight part number

TLR-4225

450 psi at 650°F (31 bar at 343°C)

5000 psi at 1000°F (345 bar at 538°C) 316/316L SS

1/4 in. O.D. x 0.049 in. AW304 SS 2.4 ft.2

(0.22 m.2)17 lb. (8 kg.)

7-03951A

TLR-4225U 4400 psi at 1000°F (303 bar at 538°C) 7-03951B

TLR-42B55000 psi at 1100°F (345 bar at 593°C)

Alloy 625 1/4 in. O.D. x 0.035 in. AW

7-03951C

TLR-42B5U 7-03951D

TLR-4BB5 Alloy 625 7-03951E

sentry-equip.com 966 Blue Ribbon Circle North, Oconomowoc, WI 53066 U.S.A. | +1-262-567-7256 | [email protected]

© 2015 Sentry Equipment Corp. All rights reserved. All product and company names are property of their respective owners. It is solely the responsibility of end users, through their own testing and analysis, to select products and materials suitable for their specific application requirements, ensure they are properly installed, safely applied and properly maintained, and to limit their use to their intended purpose. Improper selection, installation or use may result in personal injury or property damage.

S-SC&HE-SPS-00135-11 4-16

S E N T R Y T L R S I N G L E H E L I C A L T U B E > S A M P L E CO O L E R S > S A M P L E CO N D I T I O N I N G

4 7/8 [124 mm]

4 7/8 in. [124 mm]

11 3/16 in. [283 mm]

4 3/8 in. [111 mm]

3/4 in. [19 mm]

1/4 in. [6 mm]

13/16 in. [21 mm]1 1/4 in. [32 mm]

4 1/4 in. [108 mm]

2 1/4 in. [57 mm]

2 7/16 in. [61 mm]3 5/16 in. [84 mm]

1/8 in. [3 mm]

MOUNTING BRACKET(SUPPLIED WITH EACH COOLER)

3/4 in. FNPTcooling water inlet

1/4˝ O.D. SAMPLE INLET

1/4˝ O.D. SAMPLE OUTLET

1/2 in. FNPTcooling water outlet

NOTES:• U in model number denotes ASME stamped model.• Canadian Registration Number available for ASME stamped models only. Consult factory for CRN and other options and information.• Vessels are exempt from CE marking per PED 97/23/EC, TÜV. Vessels are below or equal to the limits set forth in Article 3, Sections 1.1, 1.2, 1.3 and Section 2 as applicable, and are designed and manufactured in

accordance with sound engineering practice (meets the general requirements of the ASME Section VIII, Division 1, Boiler And Pressure Vessel Code). Nameplate will bear the Sentry and safety instructions will be included per Article 3, Section 2.