2
PROFIRE S1 PROFIRE H PROFIRE K PROFIRE D FORCED DRAFT Dual Fuel Burners Model Sizes 1,000 - 63,000 MBH GAS, OIL AND GAS/OIL COMBINATIONS PACKAGED BURNER SYSTEM PROFIRE M

GAS, OIL AND GAS/OIL COMBINATIONS - Cleaver-Brooks Boiler ...china.cleaverbrooks.com/PDFs/CB_ProfireBurner.pdf · GAS, OIL AND GAS/OIL COMBINATIONS PACKAGED BURNER SYSTEM PROFiRE

Embed Size (px)

Citation preview

Page 1: GAS, OIL AND GAS/OIL COMBINATIONS - Cleaver-Brooks Boiler ...china.cleaverbrooks.com/PDFs/CB_ProfireBurner.pdf · GAS, OIL AND GAS/OIL COMBINATIONS PACKAGED BURNER SYSTEM PROFiRE

PROFiRE S1

PROFiRE H PROFiRE K

PROFiRE D

FORCED DRAFTDual Fuel BurnersModel Sizes 1,000 - 63,000 MBH

GAS, OIL AND GAS/OIL COMBINATIONS PACKAGED BURNER SYSTEM

PROFiRE M

Page 2: GAS, OIL AND GAS/OIL COMBINATIONS - Cleaver-Brooks Boiler ...china.cleaverbrooks.com/PDFs/CB_ProfireBurner.pdf · GAS, OIL AND GAS/OIL COMBINATIONS PACKAGED BURNER SYSTEM PROFiRE

COMMERCIAL, INDUSTRIAL, AND INSTITUTIONAL APPLICATIONS

Versatile in ApplicationSuitable for all types of boilers. The ProFire line features forced draft design, air atomizing, or pressure atomizing models.

UL and cUL ListedCSD-1, I.R.I., FM, or other regulatory control options available. Every ProFire burner is assembled and fire tested at the factory.

Forced Draft Design Advanced design aluminum impeller with backwards-inclined vanes supplies combustion air. This highly efficient impeller maintains its original balance by not collecting dirt on the blades as will ordinary forward-curved blowers.

Reverse Curve Fan Offers:• Low Fan Motor hp Requirements • Self-Cleaning for Lower Maintenance Costs • High Resistance to Stack Draft Fluctuations • Quiet Operation

Dual Fuel CapabilityUse either gas or oil alternately depending on the low-est cost fuel by just the flip of a switch. No mechanical or other adjustments are necessary.

The gas manifold is standard on all oil burners for future gas conversion.

Air Atomizing SystemThe air atomizing system features a positive displace-ment piston type oil metering unit and a rotary vane type air compressor. Accurate and reliable at all firing rates.

Optional EquipmentA full line of accessories are available for the burners, such as:

• Parallel positioning systems • Remote oil pumps • Inverted housing arrangement • NEMA 4 or 12 components • Steam atomizing

CAPACITIES AND SPECIfICATIONS ProFire S1: 46,200,000 Btu to 63,000,000 Btu/h 330 to 450 USGPH 1,100 to 1,500 Boiler HP Air atomizing system

ProFire D: 4,200,000 to 42,000,000 Btu/h 30 to 300 USGPH 100 to 1,000 Boiler HP Air atomizing system

ProFire M: 1,400,000 to 10,500,000 Btu/h 10 to 75 USGPH 30 to 250 Boiler HP Air atomizing system

ProFire H: 1,000,000 to 12,500,000 Btu/h 7 to 90 USGPH 24 to 297 Boiler HP Pressure atomizing system Air atomizing optional for PFH50 to 125

ProFire K: 1,250,000 to 14,650,000 9 to 105 USGPH 30 to 350 Boiler HP Pressure atomizing system Air atomizing optional for PFK54 to 145

C-B Profire Series

221 Law Street · Thomasville, GA 31792 414-359-0600 · 800-250-5883

[email protected] · cleaverbrooks.com

Printed in the USA©2009 Cleaver-Brooks, Inc

CB-797605/10