  • With its special design, the GCU combines all advantages of economic, operationally reliable and environmentally friendly combustion on sea.

    Technical data sheetGas Combustion Unit GCU-Series

    Gas Combustion Unit GCU-Series

    Technical data: GCUCapacity 0.15-6.5 t/h methane

    LNG carriers

    FSRU

    Product information

    Rain-proof design to avoid corrosion and wearing of the GCU components, especially the burner and the combustion chamber bottom

    The inner lining in the combustion chamber provides a cold and therefore strong structure of the GCU

    High air excess provides low flame temperature for low heat radiation and low NOX emissions

    No flame touching of the combustion chamber wall if the ship is rolling in heavy sea and therefore no wear-ing or damaging of the combustion chamber

    No belt driven fans for low maintenance cost

    Oil pilot burner for unlimited continuous operation if required during special circumstances

    Controlled fuel air ratio for safe combustion and low emissions

    For maintenance it is possible to remove or replace inner parts like combustion chamber and burner via funnel

    Gap between combustion chamber and outer shell is accessible

    100 % free flow possible All gases are completely burned

  • 0-07

    50-0

    057-

    02

    Burner dimensions* and weight

    Model A

    mm

    B

    mm

    C

    mm

    D

    mm

    E

    mm

    F

    mm

    G

    mm

    H

    mm

    I

    mm

    K

    mm

    Burner weight**

    kg (ca,)

    GCU 300 6,100 2,900 2,600 5,230 800 1,650 1,200 2,200 2,600 1,300 36,000

    GCU 450 6,900 4,880 3,620 5,310 1,530 2,800 1,800 3,150 4,000 1,400 40,000

    GCU 550 7,400 5,400 4,010 6,310 1,790 2,800 1,800 3,800 5,000 1,500 46,000

    GCU 650 7,850 5,900 4,410 6,580 2,000 3,100 1,800 3,800 5,000 1,500 50,000

    Burner data

    Model Boil-off-Gas (100% CH4)

    t/h

    P

    MW

    Flue gas temperature

    C

    Flue gas fl ow

    m3N/s

    GCU 300 3.0 41.5 450 77.75

    GCU 450 4.5 62.3 450 116.61

    GCU 550 5.5 76.1 450 142.53

    GCU 650 6.5 89.9 450 168.44

    Dimensions GCU-Series

    SAACKE GmbHSdweststrae 1328237 Bremen, Germany

    Tel. +49 421 6495-0Fax +49 421 6495-5363

    [email protected] www.saacke.com

    * details and other sizes on demand ** including insulation

    G

    F

    F

    E

    Plan view

    I

    H

    K

    A

    D

    C

    B

    Front view