1 •Outer fan casing manufactured from powder coated Aluminium providing a lightweight construction. •Supplied diffuser fitted with a discrete aesthetic front facia manufactured from a robust ABS plastic in white RAL 9010. •An ultra-quiet EC motor/fan assembly for energy saving, mounted on ball bearings that guarantee a longer product life and is suitable for cold climates. •G4 filter fitted as standard with large surface area to provide long filter life (4,5-10 years) and efficient filtration of incoming air. •Supplied with quality flexible duct to connect fan and diffuser. •Single duct connection to supply fresh clean air without the need to create holes in external brick walls. •All fans are individually tested before leaving the factory and are designed and manufactured to procedures defined in BS EN Installation manual SANO PIV LOFT Positive input ventilation unit G TECHNICAL SPECIFICATIONS PRECAUTIONS FOR INSTALLATION, USE AND MAINTENANCE Fig. 1 Please read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance with regulations relating to electrical equipment and must be installed by technically qualified personnel in accordance with all regulatory requirements. The manufacturer assumes no responsibility for damage to persons or property resulting from failure to observe the instructions contained in this booklet. •The device should not be used for applications other than those specified in this manual. •After removing the product from its packaging, verify its condition. In case of doubt, contact a qualified technician. Do not leave packaging within the reach of small children or people with disabilities. •Do not touch the appliance with wet or damp hands/feet. •This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. •Children should be supervised to ensure that they do not play with the device. •WARNING: Never use the unit without the provided flexible ducting. •WARNING: In order to avoid overheating, do not cover/close the air exit. •Do not use the product in the presence of flammable vapours, such as alcohol, insecticides, gasoline, etc. •If any abnormalities in operation are detected, disconnect the device from the mains supply and contact a qualified technician immediately. Use original spare parts only for repairs. •The electrical system to which the device is connected must comply with applicable regulations. •Before connecting the product to the power supply or the power outlet, ensure that: •The data plate (voltage and frequency) correspond to those of the electrical mains •The electrical power supply/socket is adequate for maximum device power. If not, contact a qualified technician. •Operating temperature: 0°C up to +40°C. •Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.). •Do not immerse the device or its parts in water or other liquids. •Turn off the main switch whenever a malfunction is detected or in case of cleaning/maintenance. •For installation an omnipolar switch should be incorporated in the fixed wiring, in accordance with the wiring regulations, to provide a full disconnection under overvoltage category III conditions (contact opening distance equal to or greater than 3mm). •Do not obstruct the fan or exhaust grille to ensure optimum air passage. •Ensure adequate air supply into the room in compliance with existing regulations in order to ensure proper device operation •If the environment in which the product is installed also houses a fuel-operating device (water heater, methane stove etc., that is not a “sealed chamber” type), it is essential to ensure adequate air intake, to ensure good combustion and proper equipment operation. •Install the product so that the impeller is not accessible from the air outlet side as verified by contact with the Test Finger (test probe “B” of the norm EN61032) in compliance with the current safety regulations. INTRODUCTION The Elta SANO PIV LOFT is a positive input ventilation unit suitable for installation in a loft. It continuously supplies fresh air through a single discharge diffuser, situated on the ceiling of the top floor in a central hallway or landing. The unit is suitable for hanging or roof joist mounting.

G Installation manual SANO PIV LOFT Positive input ......The SANO PIV LOFT unit runs continuously in your loft at a low level supplying fresh clean air into your home. This fresh air

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: G Installation manual SANO PIV LOFT Positive input ......The SANO PIV LOFT unit runs continuously in your loft at a low level supplying fresh clean air into your home. This fresh air

1

•OuterfancasingmanufacturedfrompowdercoatedAluminiumprovidingalightweightconstruction.•SupplieddiffuserfittedwithadiscreteaestheticfrontfaciamanufacturedfromarobustABSplasticinwhiteRAL9010.•Anultra-quietECmotor/fanassemblyforenergysaving,mountedonballbearingsthatguaranteealongerproductlifeandissuitableforcoldclimates.

•G4filterfittedasstandardwithlargesurfaceareatoprovidelongfilterlife(4,5-10years)andefficientfiltrationofincomingair.•Suppliedwithqualityflexibleducttoconnectfananddiffuser.•Singleductconnectiontosupplyfreshcleanairwithouttheneedtocreateholesinexternalbrickwalls.•AllfansareindividuallytestedbeforeleavingthefactoryandaredesignedandmanufacturedtoproceduresdefinedinBSEN

Installation manualSANO PIV LOFT Positive input ventilation unit

G

TECHNICAL SPECIFICATIONS

PRECAUTIONS FOR INSTALLATION, USE AND MAINTENANCE

Fig. 1

Questo documento è protetto dalle leggi vigenti in materia di privacy e copyright. Nè è vietata la copia, la diffusione senza autorizzazione di Aerauliqa srlThis document is protected by privacy and copyright laws. No part of this document may be reproduced, adapted, trasmitted or disclosed without the specific written consent of Aerauliqa srl. All right are reserved.

aera aqilu

AERAULIQA SRLSede legale / Registered office: via Corsica 10, 25125 BresciaSede operativa / Warehouse-offices: via E. Lorandi 4, 25080 Nuvolera (Bs)Tel: +39 030 674681 Fax: +39 030 6872149C.F. e P.IVA 03369930981 - REA BS-528635www.aerauliqa.it

Descrizione/Description:

Materiale/Material: Data/Date: Firma/Signature:NELSON JAMES K.08/11/2016-

DIMENSIONALPIV150 - REV1 - NEW ELECTRONIC BOARD

Rev. Descrizione/Description Data/Date Firma/Sign.

02 Variata l'altezza da 410 a 400. 13/01/16 F.M.

\PIV

\150

-REV

1\2D

\AQ

D.0

0514

.04-

Dim

ens-

PIV1

50-R

EV1

ARC

HIV

IO C

AD: AQD.00514.05 - 1:7

No. Dis/No. Drawing: Codice/Code: Scala/Scale:-

Peso/Weight:

T:\A

rchi

vio

Pro

getti

Indu

stria

le\In

-Lin

e_Bo

x\

03 Variate le dimensioni e cambiato posizionamento filtro. 09/06/16 F.M.

Ø15

0

210

482,6

454

530

605

Ø904 Inserita scatola morsettiera più grande per nuovo circuito. 04/07/16 F.M.

05

407

260

380

236,

514

3,5

395

05 Modifica della dimensione del PIV Loft 08/11/16 N.J.K

Pleasereadthismanualcarefullybeforeusingtheproductandkeepitinasafeplaceforreference.Thisproductwasconstructeduptostandardandincompliancewithregulationsrelatingtoelectricalequipmentandmustbeinstalledbytechnicallyqualifiedpersonnelinaccordancewithallregulatoryrequirements.Themanufacturerassumesnoresponsibilityfordamagetopersonsorpropertyresultingfromfailuretoobservetheinstructionscontainedinthisbooklet.

•Thedeviceshouldnotbeusedforapplicationsotherthanthosespecifiedinthismanual.•Afterremovingtheproductfromitspackaging,verifyitscondition.Incaseofdoubt,contactaqualifiedtechnician.Donotleavepackagingwithinthereachofsmallchildrenorpeoplewithdisabilities.

•Donottouchtheappliancewithwetordamphands/feet.•Thisappliancecanbeusedbychildrenagedfrom8yearsandaboveandpersonswithreducedphysical,sensoryormentalcapabilitiesor lackofexperienceandknowledge if theyhavebeengivensupervisionor instructionconcerninguseof theapplianceinasafewayandunderstandthehazardsinvolved.Childrenshallnotplaywiththeappliance.Cleaningandusermaintenanceshallnotbemadebychildrenwithoutsupervision.

•Childrenshouldbesupervisedtoensurethattheydonotplaywiththedevice.•WARNING:Neverusetheunitwithouttheprovidedflexibleducting.•WARNING:Inordertoavoidoverheating,donotcover/closetheairexit.•Donotusetheproductinthepresenceofflammablevapours,suchasalcohol,insecticides,gasoline,etc.•Ifanyabnormalitiesinoperationaredetected,disconnectthedevicefromthemainssupplyandcontactaqualifiedtechnicianimmediately.Useoriginalsparepartsonlyforrepairs.

•Theelectricalsystemtowhichthedeviceisconnectedmustcomplywithapplicableregulations.•Beforeconnectingtheproducttothepowersupplyorthepoweroutlet,ensurethat:•Thedataplate(voltageandfrequency)correspondtothoseoftheelectricalmains•Theelectricalpowersupply/socketisadequateformaximumdevicepower.Ifnot,contactaqualifiedtechnician.•Operatingtemperature:0°Cupto+40°C.•Donotleavethedeviceexposedtoatmosphericagents(rain,sun,snow,etc.).•Donotimmersethedeviceoritspartsinwaterorotherliquids.•Turnoffthemainswitchwheneveramalfunctionisdetectedorincaseofcleaning/maintenance.•Forinstallationanomnipolarswitchshouldbeincorporatedinthefixedwiring,inaccordancewiththewiringregulations,toprovideafulldisconnectionunderovervoltagecategoryIIIconditions(contactopeningdistanceequaltoorgreaterthan3mm).

•Donotobstructthefanorexhaustgrilletoensureoptimumairpassage.•Ensureadequateairsupplyintotheroomincompliancewithexistingregulationsinordertoensureproperdeviceoperation•Iftheenvironmentinwhichtheproductisinstalledalsohousesafuel-operatingdevice(waterheater,methanestoveetc.,thatisnota“sealedchamber”type),itisessentialtoensureadequateairintake,toensuregoodcombustionandproperequipmentoperation.

•InstalltheproductsothattheimpellerisnotaccessiblefromtheairoutletsideasverifiedbycontactwiththeTestFinger(testprobe“B”ofthenormEN61032)incompliancewiththecurrentsafetyregulations.

INTRODUCTIONTheEltaSANOPIVLOFTisapositiveinputventilationunitsuitableforinstallationinaloft.Itcontinuouslysuppliesfreshairthroughasingledischargediffuser,situatedontheceilingofthetopfloorinacentralhallwayorlanding.Theunitissuitableforhangingorroofjoistmounting.

Page 2: G Installation manual SANO PIV LOFT Positive input ......The SANO PIV LOFT unit runs continuously in your loft at a low level supplying fresh clean air into your home. This fresh air

2

UnitSettingTheSANOPIVLOFTunitrunscontinuouslyinyourloftatalowlevelsupplyingfreshcleanairintoyourhome.Thisfreshairdilutesthestaleandhumidairinyourhouseandisagreatwaytopreventandevencurecondensationdampnessandmouldproblems.Theunitsettingisselectedbytheinstallertosuitthesize,layout,thermalpropertiesandmoistureproductioninthehome.Gettingthissettingrightisveryimportantandisoftenbasedontheexperienceoftheinstaller.Itisasimportantnottooverventilateasitistounderventilateahome.EltaFansResidentialteamhasmuchexperienceinsettingPIVunitsandcanbecontactedanytimeforadvice.Theunithasnumerousautomaticspeedadjustmentstooptimiseventilationandenergyuse.

NormalModeTheunitwill run inthismodeforthevastmajorityof itstimesupplyinguntil theunit’s integral temperaturesensorswitchesitto“HeatRecovery”or“Standby”mode,orthe“OverrideBoost”mode(ifconnectedviaasuitableswitch)isactivatedbytheoccupants.Thisrateissetvia3dipswitchesshowninthewiringdiagram,whenleavingthefactorythisissetto29l/s.

HeatRecoveryModeWhentheairintheloftisaboveatriggertemperaturetheunitwillautomaticallyswitchtoanincreasedspeed.Thisincreaseinspeedtakesadvantageofotherwiseunusedenergyintheroofspaceandbringsitinsidethehousepotentiallyreducingheatingbills.

This trigger temperature is adjustablebetween15-25°C, via trimmnerV1 (shown in thewiringdiagram).Thedefaultwhenleavingthefactoryis19°C.Itisusuallyadjustedto1°Cabovethetemperaturethehomeisheatedto.

TheamountthefanboostsisadjustableviatheHYtrimmer(shownindiagram)theincreaseisadjustablebetween-50%and50%ofthetricklespeed.FOR EXAMPLE:The trickle is set at 29l/s, HY trimmer is in the default position (+20%).When triggered the boostwill be29+5.8=34.8l/s.

SummerStandbyModeThesummershutdownfunctionlimitsthechanceofthehouseoverheatingwhentemperaturesintheloftreachalevelthatisuncomfortable.Theunitwillessentiallyswitchoffwhenthelofttemperaturereachesa“Standby”triggertemperaturetosaveenergyandpreventundesirablewarmairbeingintroducedunnecessarilyintothehome.Somecustomerswishtohavetheirunitoperatingallyearrounde.g.forRadonGascontrolorpollenfiltrationduringsummer.That’swhyanadjustabletriggertemperaturehasbeenincorporated.ThistemperaturesetpointisadjustableviatrimmerV2(showninthewiringdiagram)between20°and40°C,thedefaultwhenleavingthefactoryis26°C.

OverrideBoostModeTheunit’sautomaticcontrolscanbeoverriddentooperatetheunitatitsmaximumairflowbymeansofauserswitch.The override boost can be triggered via a dedicated external volt free switch connectingGND and S3 terminals (shown indiagram).Purgeoperationoverridesanyotherspeedsettings.Thisfunctioncanbeincorporatedatinstallationstageorlater.Theunitwillfunctionautomaticallywithorwithoutit.Topreventexcessivelywarmairbeingsuppliedtothehomeandtoprotectthecomponentsoftheunit,thepurgewillnotoperateabove40°C.

OPERATION

Model Airflow l/s

PowerW max

Sound pressuredB(A) @3m

SANOPIVLOFT 80 29 27

Unit setting “Normal Mode”Airflow l/s

Max FilterChange Interval

Years

SANO PIV LOFT

“Heat Recovery”Airflow l/s

“Normal” ModePower Consumption

Watts

1 17 10 9-26(default20,4) 2,0

2 21 10 11-32(default25,2) 2,5

3 25 9 13-38(default30) 3,3

4 29(default) 7,5 15-44(default34,8) 3,8

5 33 6,5 17-50(default39,6) 4,1

6 37 6 19-56(default44,4) 4,6

7 41 5,5 21-62(default49,2) 5,6

8 45 5 23-68(default54) 6,5

ISO9001:2008.•PowerSupply230V-50/60Hz.

Page 3: G Installation manual SANO PIV LOFT Positive input ......The SANO PIV LOFT unit runs continuously in your loft at a low level supplying fresh clean air into your home. This fresh air

3

2

MAINTENANCEMakesurethemainssupplyoftheunitisdisconnectedbeforeperforminganymaintenance.Themaintenancemustbecarriedoutbyaqualifiedtechnicianandinaccordancewithlocalrulesandregulations.FiltersofthePIVunitrequirechangingaccordingtothefilterchangeperiod.WhenthefiltersaredirtylessairwillbesuppliedbythePIVunitandimpacttheeffectivenessoftheunit.Inareasofhighpollutione.g.besidemainroadsmoreregularreplacementmayberequired.FilterscanbesuppliedbyEltaFans,partcode-021-PIV-FILT.Filtersshouldbecheckedannuallyandcleanedwithavacuumcleanerifrequired.Ifadropinventilationratesarenoticedthiscouldalsobeanindicationthefiltersneedinspecting.Theexhaustdiffusershouldrequirelittlecleaning,ifrequiredthefrontfaciaiseasilyremovedandwashedundercoldwater.

1

3

Year Required Maintenance1 Inspect,cleandiffuserifrequired.

2 Inspect,cleandiffuserifrequired.

3 Inspect,cleandiffuserifrequired,replacefilterifrequired.

4 Inspect,cleandiffuserifrequired,replacefilterifrequired.

5 Inspect,cleandiffuserifrequired,replacefilterifrequired.

STANDARD CONFORMITY2014/35/EULowVoltageDirective(LVD)2014/30/EUElectromagneticCompatibility(EMC),inconformitywiththefollowingstandards:ElectricalSafety:EN60335-1(2012)+A11+A13;EN60335-2-80(2003)+A1+A2.ElectromagneticCompatibility:EN55014-1(2017);EN55014-2(2015);EN61000-3-2(2014);EN61000-3-3(2013).

Page 4: G Installation manual SANO PIV LOFT Positive input ......The SANO PIV LOFT unit runs continuously in your loft at a low level supplying fresh clean air into your home. This fresh air

4

DIMENSIONS (mm)

Priortoinstallationtheloftshouldbeinspectedtoensurethereisadequateventilationoftheloft.Thepresenceofdaylightisagoodindicationofaloftthatissuitablyventilated.Adviceshouldbeobtainediftheloftistightlysealed.Thereshouldbenoleaksfromthehouseintotheloft.Extractorfansshouldnotdischargestraightintotheloft,lofthatchesandholesforceilinglightsshouldbeadequatelysealed.

INSTALLATION

WHAT IS IN THE BOX

Whenfittingthediffusernearasmokealarmtheblankingplatesprovidedmustbefittedtoavoidblowingairoverthesmokealarmandaffectingitsoperation.Iftheunitisinstalledinadwelling3storeysorabove,itshouldbelinkedtoasmokealarminsuchawaythatpowerisremovedfromthePIVifthesmokealarmisactivated.Ourstandarddiffuserisnotsuitableforinstallationin3storeyorabovehomesorfireprotectedareas.Ifyourequireguidanceonanyoftheabove,pleasecontactEltaFans.

DIFFUSER

5 6

1.Ventilationunit

2.Filter

3.Pipe

4.O&MManual

5.Diffuser

6.4xScrew+wallplug

7.4xWoodscrew

8.Installerlabel

9.2xMetalclamp

10.2xMylarflap

11.Hangingkit

12.Fusedspur

Weight:5.1kg

Questo documento è protetto dalle leggi vigenti in materia di privacy e copyright. Nè è vietata la copia, la diffusione senza autorizzazione di Aerauliqa srlThis document is protected by privacy and copyright laws. No part of this document may be reproduced, adapted, trasmitted or disclosed without the specific written consent of Aerauliqa srl. All right are reserved.

aera aqilu

AERAULIQA SRLSede legale / Registered office: via Corsica 10, 25125 BresciaSede operativa / Warehouse-offices: via E. Lorandi 4, 25080 Nuvolera (Bs)Tel: +39 030 674681 Fax: +39 030 6872149C.F. e P.IVA 03369930981 - REA BS-528635www.aerauliqa.it

Descrizione/Description:

Materiale/Material: Data/Date: Firma/Signature:NELSON JAMES K.08/11/2016-

DIMENSIONALPIV150 - REV1 - NEW ELECTRONIC BOARD

Rev. Descrizione/Description Data/Date Firma/Sign.

02 Variata l'altezza da 410 a 400. 13/01/16 F.M.

\PIV

\150

-REV

1\2D

\AQ

D.0

0514

.04-

Dim

ens-

PIV1

50-R

EV1

ARC

HIV

IO C

AD: AQD.00514.05 - 1:7

No. Dis/No. Drawing: Codice/Code: Scala/Scale:-

Peso/Weight:

T:\A

rchi

vio

Pro

getti

Indu

stria

le\In

-Lin

e_Bo

x\

03 Variate le dimensioni e cambiato posizionamento filtro. 09/06/16 F.M.

Ø15

0

210

482,6

454

530

605

Ø904 Inserita scatola morsettiera più grande per nuovo circuito. 04/07/16 F.M.

05

407

260

380

236,

514

3,5

395

05 Modifica della dimensione del PIV Loft 08/11/16 N.J.K

Questo documento è protetto dalle leggi vigenti in materia di privacy e copyright. Nè è vietata la copia, la diffusione senza autorizzazione di Aerauliqa srlThis document is protected by privacy and copyright laws. No part of this document may be reproduced, adapted, trasmitted or disclosed without the specific written consent of Aerauliqa srl. All right are reserved.

aera aqilu

AERAULIQA SRLSede legale / Registered office: via Corsica 10, 25125 BresciaSede operativa / Warehouse-offices: via E. Lorandi 4, 25080 Nuvolera (Bs)Tel: +39 030 674681 Fax: +39 030 6872149C.F. e P.IVA 03369930981 - REA BS-528635www.aerauliqa.it

Descrizione/Description:

Materiale/Material: Data/Date: Firma/Signature:NELSON JAMES K.08/11/2016-

DIMENSIONALPIV150 - REV1 - NEW ELECTRONIC BOARD

Rev. Descrizione/Description Data/Date Firma/Sign.

02 Variata l'altezza da 410 a 400. 13/01/16 F.M.

\PIV

\150

-REV

1\2D

\AQ

D.0

0514

.04-

Dim

ens-

PIV1

50-R

EV1

ARC

HIV

IO C

AD: AQD.00514.05 - 1:7

No. Dis/No. Drawing: Codice/Code: Scala/Scale:-

Peso/Weight:

T:\A

rchi

vio

Pro

getti

Indu

stria

le\In

-Lin

e_Bo

x\

03 Variate le dimensioni e cambiato posizionamento filtro. 09/06/16 F.M.

Ø15

0

210

482,6

454

530

605

Ø904 Inserita scatola morsettiera più grande per nuovo circuito. 04/07/16 F.M.

05

407

260

380

236,

514

3,5

395

05 Modifica della dimensione del PIV Loft 08/11/16 N.J.K

Questo documento è protetto dalle leggi vigenti in materia di privacy e copyright. Nè è vietata la copia, la diffusione senza autorizzazione di Aerauliqa srlThis document is protected by privacy and copyright laws. No part of this document may be reproduced, adapted, trasmitted or disclosed without the specific written consent of Aerauliqa srl. All right are reserved.

aera aqilu

AERAULIQA SRLSede legale / Registered office: via Corsica 10, 25125 BresciaSede operativa / Warehouse-offices: via E. Lorandi 4, 25080 Nuvolera (Bs)Tel: +39 030 674681 Fax: +39 030 6872149C.F. e P.IVA 03369930981 - REA BS-528635www.aerauliqa.it

Descrizione/Description:

Materiale/Material: Data/Date: Firma/Signature:NELSON JAMES K.08/11/2016-

DIMENSIONALPIV150 - REV1 - NEW ELECTRONIC BOARD

Rev. Descrizione/Description Data/Date Firma/Sign.

02 Variata l'altezza da 410 a 400. 13/01/16 F.M.

\PIV

\150

-REV

1\2D

\AQ

D.0

0514

.04-

Dim

ens-

PIV1

50-R

EV1

ARC

HIV

IO C

AD: AQD.00514.05 - 1:7

No. Dis/No. Drawing: Codice/Code: Scala/Scale:-

Peso/Weight:

T:\A

rchi

vio

Pro

getti

Indu

stria

le\In

-Lin

e_Bo

x\

03 Variate le dimensioni e cambiato posizionamento filtro. 09/06/16 F.M.

Ø15

0

210

482,6

454

530

605

Ø904 Inserita scatola morsettiera più grande per nuovo circuito. 04/07/16 F.M.

05

407

260

380

236,

514

3,5

395

05 Modifica della dimensione del PIV Loft 08/11/16 N.J.K

285

Page 5: G Installation manual SANO PIV LOFT Positive input ......The SANO PIV LOFT unit runs continuously in your loft at a low level supplying fresh clean air into your home. This fresh air

5

Ensurethatflexibleductingispulledtightandisnotkinkedorcrushed.Thiswillimpacttheperformanceoftheunitandmaycausenoise.

PIV UNIT

9 10

7 8

Ø 150/160

JOIST MOUNTINGRemovethefittedbracketsfromthetopandfixthematthebottom(pre-setholes).Pleaseensureanyunusedscrewholesarefilledwiththescrewsprovided.Pleaseensurethatthereisatleast150mmclearallaroundtheunit,includingthebottom,toallowairtoentertheunitviathefilters.Pleasepayparticularattentiontomakesurenomineralwoolorother loft insulationmaterialisatleast150mmawayfromanypartoftheunit.Timberspacersonjoistsmayberequiredtoachievethis.

1211

Page 6: G Installation manual SANO PIV LOFT Positive input ......The SANO PIV LOFT unit runs continuously in your loft at a low level supplying fresh clean air into your home. This fresh air

6

ELECTRICAL WIRINGThe unit must be earthed

13Controlbox

FAN SPEED SETTING

DIP1 DIP2 DIP3 DIP4 Trickle Volume (l/s)

0 0 0 x 17

0 0 1 x 21

0 1 0 x 25

0 1 1 x 29(default)

1 0 0 x 33

1 0 1 x 37

1 1 0 x 41

1 1 1 x 45

1 2 3 4

1

0

Trimmer label Operation Range Default

V1 Heatrecoverytriggertemperature 15to25°C 19°C

V2 Summerstandbytriggertemperature 20to40°C 26°C

HY %increaseofHeatRecoverymode -50%oftrickleto50%oftrickle 0

Toadjustthetrickleflowrateusethedipswitchesshowninthediagramoffigure13.

14

Pre-cabled

TheSANOPIVpowercablehasbeenprewired toaid installation. Ifusingadditionalcontrol cables theseshouldbepassedthroughthesparecablegland.

PrewiredACmainscable

Brown-LiveBlue-NeutralGreen/Yellow-Earth

15

Page 7: G Installation manual SANO PIV LOFT Positive input ......The SANO PIV LOFT unit runs continuously in your loft at a low level supplying fresh clean air into your home. This fresh air

7

TRIMMER SETTING

15°C

16,5°C

18,5°C20°C

21,5°C

23,5°C

25°C

V1

20°C

23°C

27°C30°C

33°C

37°C

40°C

V2

0

-50% TRICKLE +50% TRICKLE

HY

-40% +40%

-20% +20%

Page 8: G Installation manual SANO PIV LOFT Positive input ......The SANO PIV LOFT unit runs continuously in your loft at a low level supplying fresh clean air into your home. This fresh air

8

a) Mark - ELTA FANS

b) Model - SANO PIV LOFT

c) SEC class - C

c1) SEC warm climates kWh/m2.a -10,7

c2) SEC average climates kWh/m2.a -25,1

c3) SEC cold climates kWh/m2.a -50,2

Energy label - No

d) Unit typology - Residential - unidirectional

e) Type of drive - Multi-speed drive

f) Type of Heat Recovery System - Absent

g) Thermal efficiency of heat recovery % N/A

h) Maximum flow rate m3/h 288

i) Electric power input at maximum flow rate W 29

j) Sound power level (LWA) dBA 43

k) Reference flow rate m3/h 202

l) Reference pressure difference Pa 10

m) Specific power input (SPI) W/m3/h 0,054

n1) Control factor - 0,65

n2) Control typology - Local demand control

o1) Maximum internal leakage rate % N/A

o2) Maximum external leakage rate % N/A

p1) Internal mixing rate % N/A

p2) External mixing rate % N/A

q) Visual filter warning - N/A

r) Instructions to install regulated grilles - check the instruction booklet

s) Internet address for pre/disassembly instructions - www.eltafans.com

t) Airflow sensitivity to pressure variations % 10

u) Indoor/outdoor air tightness m3/h 101

v1) AEC - Annual electricity consumption - warm climates kWh 0,4

v2) AEC - Annual electricity consumption - average climates kWh 0,4

v3) AEC - Annual electricity consumption - cold climates kWh 0,4

w1)AHS - Annual heating saved - warm climates kWh 11,9

w2)AHS - Annual heating saved - average climates kWh 26,2

w3)AHS - Annual heating saved - cold climates kWh 51,3

ErP Directive - Regulations 1253/2014 - 1254/2014

Page 9: G Installation manual SANO PIV LOFT Positive input ......The SANO PIV LOFT unit runs continuously in your loft at a low level supplying fresh clean air into your home. This fresh air

9

GUARANTEETheproductisofferedwithafiveyearwarranty.

First year of warranty covers parts and labour, following this period the warranty covers replacement parts only based onmaintenancehavingbeingcarriedoutinaccordancewithourliteratureandtermsandconditionsofsale.ProofofPurchase,Periodicinspectionandmaintenancewillberequiredintheeventofanywarrantyclaim.

Page 10: G Installation manual SANO PIV LOFT Positive input ......The SANO PIV LOFT unit runs continuously in your loft at a low level supplying fresh clean air into your home. This fresh air

10

NOTES

Page 11: G Installation manual SANO PIV LOFT Positive input ......The SANO PIV LOFT unit runs continuously in your loft at a low level supplying fresh clean air into your home. This fresh air

11

NOTES

Page 12: G Installation manual SANO PIV LOFT Positive input ......The SANO PIV LOFT unit runs continuously in your loft at a low level supplying fresh clean air into your home. This fresh air

001220-06-1018

EltaFansLimitedBuildingServices46ThirdAvenuePensnettTradingEstateKingswinfordWestMidlandsDY67USUnitedKingdomT:+44(0)1384275800F:+44(0)1384275810E:[email protected]