4
Side A Side B JAPANESE ENGLISH Side B RS-232C COMMUNICATION BOARD FX1N-232-BD USER’S GUIDE JY992D84401D This manual only describes the specifications for RS-232C Communication Board FX 1N -232-BD. For complete operation, wiring, mounting and programming instructions please refer to the FX 1S , FX 1N HARDWARE MANUAL and PROGRAMMING MANUAL. These manuals should be read and understood before attempting to install or use the unit. Associated Manuals 1. Outline of Product The RS-232C communication board FX 1N -232-BD (hereafter referred to as "232BD") is connected to the FX 1S /FX 1N Series PLC basic unit, and available for the applications described below. 1.1 Features 1) Port to transfer the data using the non-procedure method between diversified RS-232C equipment such as personal computer, bar code reader and printer 2) Port to transfer the data using a dedicated protocol between an RS-232C equipment 3) Port to connect a programming tool 1.2 Outside dimensions and name of each part Manual name Manual No. Description FX 1S Series Hardware Manual JY992D83901 Describes contents related to hardware of FX 1S Series PLC such as specifications, wiring and installation. FX 1N Series Hardware Manual JY992D88201 Describes contents related to hardware of FX 1N Series PLC such as specifications, wiring and installation. FX Programming Manual II JY992D88101 Describes instructions in FX 1S /FX 1N /FX 2N /FX 2NC Series. FX Series User's Manual - Data Communication Edition JY997D16901 Describes contents related to communication available in FX Series PLC such as wiring, communication setting and program examples. (Make sure to read this manual.) TXD RXD 38.5(1.52) 43(1.69) Unit: mm (inches) Mounting hole (2- φ 3.5) Connector for PLC RXD LED: Lit during receive. TXD LED: Lit during send. Connector for RS-232C equipment The top face of this connector is higher than the top face of the PLC panel cover by approximately 7 mm. Hole for connector fixing screw (#4-40UNC) Accessories:Top cover for board 1 M3 screw to mount board 2 M3 screw to fix top cover 1 Connector for display module FX 1N -5DM or memory cassette FX 1N -EEPROM-8L

FX1N-232-BD - User's Guide JY992D84401-D (10.10)

Embed Size (px)

Citation preview

Page 1: FX1N-232-BD - User's Guide JY992D84401-D (10.10)

manual confers no industrial property rights or any rights of any other kind, nor does it confer any t licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving trial property rights which may occur as a result of using the contents noted in this manual.

HEAD OFFICEHIMEJI WORKS

: TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN : 840, CHIYODA CHO, HIMEJI, JAPAN

TION B

ER’S

Y992D8

ication Botions plea

install or

cription

hardwarestallation

hardwarenstallation

/FX1N/FX

Edition

communimmunication setting and program this manual.)

The communication connector of the 232BD is the D-sub, 9-pin socket type. The table below shows the

guration

guration, refer to the FX Series User's Ma unication Edition offered

rocedure

the power before installing the 232BD.

oard 232BD (function expansion board)

onal equipment

ard (2 pieces) (offered as accessories of board)

d (offered as an accessory of board)

p cover (offered as an accessory of board)

Note: Do not remove this screw of FX1S.

Pin No. Signal Name Function

1 CDReceive carrier detection

Turns ON when carrier for data receive is detected.

2 RD(RXD)Receive data input

Receive data (RS-232C equipment → 232BD)

3 SD(TXD) Send data input-232C equipment)

4 ER(DTR) Send requestn RS-232C equipment y for receive.

5 SG(GND) Signal ground

6 DR(DSR) Send enabled send request is given uipment

7,8,9 Not used

��

��

�����

��

��

ormance specifications

ission standard In conformance to RS-232C

m transmission e

15 m (49ft) maximum

l equipment tion method

D-sub, 9-pin type (pin socket: manufactured by JST Mfg.) with JES-9P-2A3A (#4-40UNC, inch screw thread type)

-pin layout1: CD 2: RD(RXD) 3: SD(TXD) 4: ER(DTR) 5: SG(GND) 6: DR(DSR) 7, 8, 9: NC (not used)

on (LED) RXD, TXD

Communication method Half duplex, bi-directional

Communication procedure

Non-procedure, dedicated protocol 1 procedure, dedicated protocol 4 procedure, protocol for programming tool

Insulation Not insulated

Guidelines for the safety of the user and protection of the RS-232C Communica-on Board FX1N-232-BD

This manual has been written to be used by trained and competent personnel. This is definedby the European directives for machinery, low voltage and EMC.

If in doubt at any stage during the installation of the RS-232C Communication Board FX1N-232-BD always consult a professional electrical engineer who is qualified and trained to the local andnational standards. If in doubt about the operation or use of the RS-232C Communication BoardFX1N-232-BD please consult the nearest Mitsubishi Electric distributor.

Under no circumstances will Mitsubishi Electric be liable or responsible for any consequentialage that may arise as a result of the installation or use of this equipment.

examples and diagrams shown in this manual are intended only as an aid to understanding text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual of the product based on these illustrative examples.

ing to the very great variety in possible application of this equipment, you must satisfyrself as to its suitability for your specific application.

Manual number : JY992D84401

Manual revision : D

Date : October 2010

401DEffective Oct. 2010Specifications are subject to change without notice

on

s product is designed for use in industrial applications.

nufactured by: Mitsubishi Electric Corporation2-7-3 Marunouchi, Chiyoda-ku, Tokyo, 100-8310 Japan

nufactured at: Mitsubishi Electric Corporation Himeji Works840 Chiyoda-machi, Himeji, Hyogo, 670-8677 Japan

horized Representative in the European Community:Mitsubishi Electric Europe B.V.Gothaer Str. 8, 40880 Ratingen, Germany

JY992D84

This patenindus

1. Outline of Product

The RS-232C communication board FX1N-232-BD (hereafter referred to as "232BD") is connected to theFX1S/FX1N Series PLC basic unit, and available for the applications described below.

1.1 Features

1) Port to transfer the data using the non-procedure method between diversified RS-232C equipmentsuch as personal computer, bar code reader and printer

2) Port to transfer the data using a dedicated protocol between an RS-232C equipment

3) Port to connect a programming tool

1.2 Outside dimensions and name of each part

��� ���

��������

�����

➁ ➆

Unit: mm (inches)

➀ Mounting hole (2-φ3.5)

➁ Connector for PLC

➂ RXD LED: Lit during receive.

➃ TXD LED: Lit during send.

➄ Connector for RS-232C equipment The top face of this connector is higher than the top face of thePLC panel cover by approximately 7 mm.

➅ Hole for connector fixing screw (#4-40UNC)Accessories:Top cover for board 1

M3 screw to mount board 2M3 screw to fix top cover 1

➆ Connector for display module FX1N-5DM or memory cassetteFX1N-EEPROM-8L

• Plug the communication board A) in to the connector B).

• Fix the board to the basic unit with two M3 screws C). (Tightening torque: 0.3 to 0.6 N m)

• Remove the top cover of the basic unit, and attach the top cover for board D) instead.During attachment, remove D)’ with a nipper, etc. so that the connector of the board is exposed.

• Fix the top cover with an M3 screw E). (Tightening torque: 0.3 to 0.6 N m)

• When the FX1N-5DM is used also, refer to the Hardware manual offered with the FX1S/FX1N Series PLC main unit.

• Only one function expansion board is available for one FX1S/FX1N Series PLC basic unit. Never stack up two or more function expansion boards. (Even if they are stacked up, they do not function at all.)

• The 485BD can be used with the FX1N-EEPROM-8L only for program transfer.(The FX1N-EEPROM-8L cannnot be connected continuously.)

3. Specifications

3.1 Environmental specifications

The environmental specifications are equivalent to those of the PLC main unit. (Refer to the manual of thePLC main unit.)

3.2 Power supply specifications

5V DC, 20 mA is supplied as the power from the PLC.

�� �����

dam

• All theuse

• Owyou

Attenti

• Thi

Note

• Ma

• Ma

• Aut

Side

A

Side

B JAPANESE ENGLISHSide

B

RS-232C COMMUNICA

US

J

This manual only describes the specifications for RS-232C CommunFor complete operation, wiring, mounting and programming instrucHARDWARE MANUAL and PROGRAMMING MANUAL.These manuals should be read and understood before attempting to

Associated Manuals

Manual name Manual No. Des

FX1S Series Hardware Manual

JY992D83901Describes contents related to as specifications, wiring and in

FX1N Series Hardware Manual

JY992D88201Describes contents related to as specifications, wiring and i

FX Programming Manual II

JY992D88101 Describes instructions in FX1S

FX Series User's Manual - Data Communication

JY997D16901Describes contents related toSeries PLC such as wiring, coexamples. (Make sure to read

OARD FX1N-232-BD

GUIDE

4401D

ard FX1N-232-BD.se refer to the FX1S, FX1N

use the unit.

of FX1S Series PLC such .

of FX1N Series PLC such .

2N/FX2NC Series.

cation available in FX

pin arrangement.

1.3 System confi

For the system confiseparately.

2. Installation

2.1 Installation p

Make sure to turn off

A) Communication b

B) Connector for opti

C) M3 screw to fix bo

D) Top cover for boar

E) M3 screw to fix to

1

2

3

4

5

6

7

8

9

nual - Data Comm

Send data (232BD → RS

Turns ON whebecomes read

Signal ground

Turns ON whento RS-232C eq

ti

3.3 Perf

Transm

Maximudistanc

Externaconnec

D-sub 9

Indicati

Page 2: FX1N-232-BD - User's Guide JY992D84401-D (10.10)

This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.

HEAD OFFICEHIMEJI WORKS

: TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN : 840, CHIYODA CHO, HIMEJI, JAPAN

Side

A

Side

B JAPANESE ENGLISHSide

B

RS-232C COMMUNICATION BOARD FX1N-232-BD

USER’S GUIDE

JY992D84401D

This manual only describes the specifications for RS-232C Communication Board FX1N-232-BD.For complete operation, wiring, mounting and programming instructions please refer to the FX1S, FX1N

HARDWARE MANUAL and PROGRAMMING MANUAL.These manuals should be read and understood before attempting to install or use the unit.

Associated Manuals

1. Outline of Product

The RS-232C communication board FX1N-232-BD (hereafter referred to as "232BD") is connected to theFX1S/FX1N Series PLC basic unit, and available for the applications described below.

1.1 Features

1) Port to transfer the data using the non-procedure method between diversified RS-232C equipmentsuch as personal computer, bar code reader and printer

2) Port to transfer the data using a dedicated protocol between an RS-232C equipment

3) Port to connect a programming tool

1.2 Outside dimensions and name of each part

Manual name Manual No. Description

FX1S Series Hardware Manual

JY992D83901Describes contents related to hardware of FX1S Series PLC such as specifications, wiring and installation.

FX1N Series Hardware Manual

JY992D88201Describes contents related to hardware of FX1N Series PLC such as specifications, wiring and installation.

FX Programming Manual II

JY992D88101 Describes instructions in FX1S/FX1N/FX2N/FX2NC Series.

FX Series User's Manual - Data Communication Edition

JY997D16901Describes contents related to communication available in FX Series PLC such as wiring, communication setting and program examples. (Make sure to read this manual.)

��� ���

��������

�����

➁ ➆

Unit: mm (inches)

➀ Mounting hole (2-φ3.5)

➁ Connector for PLC

➂ RXD LED: Lit during receive.

➃ TXD LED: Lit during send.

➄ Connector for RS-232C equipment The top face of this connector is higher than the top face of thePLC panel cover by approximately 7 mm.

➅ Hole for connector fixing screw (#4-40UNC)Accessories:Top cover for board 1

M3 screw to mount board 2M3 screw to fix top cover 1

➆ Connector for display module FX1N-5DM or memory cassetteFX1N-EEPROM-8L

The communication connector of the 232BD is the D-sub, 9-pin socket type. The table below shows thepin arrangement.

1.3 System configuration

For the system configuration, refer to the FX Series User's Manual - Data Communication Edition offeredseparately.

2. Installation

2.1 Installation procedure

Make sure to turn off the power before installing the 232BD.

A) Communication board 232BD (function expansion board)

B) Connector for optional equipment

C) M3 screw to fix board (2 pieces) (offered as accessories of board)

D) Top cover for board (offered as an accessory of board)

E) M3 screw to fix top cover (offered as an accessory of board)

Note: Do not remove this screw of FX1S.

• Plug the communication board A) in to the connector B).

• Fix the board to the basic unit with two M3 screws C). (Tightening torque: 0.3 to 0.6 N m)

• Remove the top cover of the basic unit, and attach the top cover for board D) instead.During attachment, remove D)’ with a nipper, etc. so that the connector of the board is exposed.

• Fix the top cover with an M3 screw E). (Tightening torque: 0.3 to 0.6 N m)

• When the FX1N-5DM is used also, refer to the Hardware manual offered with the FX1S/FX1N Series PLC main unit.

• Only one function expansion board is available for one FX1S/FX1N Series PLC basic unit. Never stack up two or more function expansion boards. (Even if they are stacked up, they do not function at all.)

• The 485BD can be used with the FX1N-EEPROM-8L only for program transfer.(The FX1N-EEPROM-8L cannnot be connected continuously.)

3. Specifications

3.1 Environmental specifications

The environmental specifications are equivalent to those of the PLC main unit. (Refer to the manual of thePLC main unit.)

3.2 Power supply specifications

5V DC, 20 mA is supplied as the power from the PLC.

Pin No. Signal Name Function

1 CDReceive carrier detection

Turns ON when carrier for data receive is detected.

2 RD(RXD)Receive data input

Receive data (RS-232C equipment → 232BD)

3 SD(TXD) Send data inputSend data (232BD → RS-232C equipment)

4 ER(DTR) Send requestTurns ON when RS-232C equipment becomes ready for receive.

5 SG(GND) Signal ground Signal ground

6 DR(DSR) Send enabledTurns ON when send request is given to RS-232C equipment

7,8,9 Not used

1

2

3

4

5

6

7

8

9

��

��

��

�����

��

��

�����

3.3 Performance specifications

Transmission standard In conformance to RS-232C

Maximum transmission distance

15 m (49ft) maximum

External equipment connection method

D-sub, 9-pin type (pin socket: manufactured by JST Mfg.) with JES-9P-2A3A (#4-40UNC, inch screw thread type)

D-sub 9-pin layout1: CD 2: RD(RXD) 3: SD(TXD) 4: ER(DTR) 5: SG(GND) 6: DR(DSR) 7, 8, 9: NC (not used)

Indication (LED) RXD, TXD

Communication method Half duplex, bi-directional

Communication procedure

Non-procedure, dedicated protocol 1 procedure, dedicated protocol 4 procedure, protocol for programming tool

Insulation Not insulated

Guidelines for the safety of the user and protection of the RS-232C Communica-tion Board FX1N-232-BD

• This manual has been written to be used by trained and competent personnel. This is definedby the European directives for machinery, low voltage and EMC.

• If in doubt at any stage during the installation of the RS-232C Communication Board FX1N-232-BD always consult a professional electrical engineer who is qualified and trained to the local andnational standards. If in doubt about the operation or use of the RS-232C Communication BoardFX1N-232-BD please consult the nearest Mitsubishi Electric distributor.

• Under no circumstances will Mitsubishi Electric be liable or responsible for any consequentialdamage that may arise as a result of the installation or use of this equipment.

• All examples and diagrams shown in this manual are intended only as an aid to understandingthe text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actualuse of the product based on these illustrative examples.

• Owing to the very great variety in possible application of this equipment, you must satisfyyourself as to its suitability for your specific application.

Manual number : JY992D84401

Manual revision : D

Date : October 2010

JY992D84401DEffective Oct. 2010Specifications are subject to change without notice

Attention

• This product is designed for use in industrial applications.

Note

• Manufactured by: Mitsubishi Electric Corporation2-7-3 Marunouchi, Chiyoda-ku, Tokyo, 100-8310 Japan

• Manufactured at: Mitsubishi Electric Corporation Himeji Works840 Chiyoda-machi, Himeji, Hyogo, 670-8677 Japan

• Authorized Representative in the European Community:Mitsubishi Electric Europe B.V.Gothaer Str. 8, 40880 Ratingen, Germany

Page 3: FX1N-232-BD - User's Guide JY992D84401-D (10.10)

This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.

HEAD OFFICEHIMEJI WORKS

: TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN : 840, CHIYODA CHO, HIMEJI, JAPAN

Side

A

Side

B JAPANESE ENGLISHSide

B

RS-232C COMMUNICATION BOARD FX1N-232-BD

USER’S GUIDE

JY992D84401D

This manual only describes the specifications for RS-232C Communication Board FX1N-232-BD.For complete operation, wiring, mounting and programming instructions please refer to the FX1S, FX1N

HARDWARE MANUAL and PROGRAMMING MANUAL.These manuals should be read and understood before attempting to install or use the unit.

Associated Manuals

1. Outline of Product

The RS-232C communication board FX1N-232-BD (hereafter referred to as "232BD") is connected to theFX1S/FX1N Series PLC basic unit, and available for the applications described below.

1.1 Features

1) Port to transfer the data using the non-procedure method between diversified RS-232C equipmentsuch as personal computer, bar code reader and printer

2) Port to transfer the data using a dedicated protocol between an RS-232C equipment

3) Port to connect a programming tool

1.2 Outside dimensions and name of each part

Manual name Manual No. Description

FX1S Series Hardware Manual

JY992D83901Describes contents related to hardware of FX1S Series PLC such as specifications, wiring and installation.

FX1N Series Hardware Manual

JY992D88201Describes contents related to hardware of FX1N Series PLC such as specifications, wiring and installation.

FX Programming Manual II

JY992D88101 Describes instructions in FX1S/FX1N/FX2N/FX2NC Series.

FX Series User's Manual - Data Communication Edition

JY997D16901Describes contents related to communication available in FX Series PLC such as wiring, communication setting and program examples. (Make sure to read this manual.)

��� ���

��������

�����

➁ ➆

Unit: mm (inches)

➀ Mounting hole (2-φ3.5)

➁ Connector for PLC

➂ RXD LED: Lit during receive.

➃ TXD LED: Lit during send.

➄ Connector for RS-232C equipment The top face of this connector is higher than the top face of thePLC panel cover by approximately 7 mm.

➅ Hole for connector fixing screw (#4-40UNC)Accessories:Top cover for board 1

M3 screw to mount board 2M3 screw to fix top cover 1

➆ Connector for display module FX1N-5DM or memory cassetteFX1N-EEPROM-8L

The communication connector of the 232BD is the D-sub, 9-pin socket type. The table below shows thepin arrangement.

1.3 System configuration

For the system configuration, refer to the FX Series User's Manual - Data Communication Edition offeredseparately.

2. Installation

2.1 Installation procedure

Make sure to turn off the power before installing the 232BD.

A) Communication board 232BD (function expansion board)

B) Connector for optional equipment

C) M3 screw to fix board (2 pieces) (offered as accessories of board)

D) Top cover for board (offered as an accessory of board)

E) M3 screw to fix top cover (offered as an accessory of board)

Note: Do not remove this screw of FX1S.

• Plug the communication board A) in to the connector B).

• Fix the board to the basic unit with two M3 screws C). (Tightening torque: 0.3 to 0.6 N m)

• Remove the top cover of the basic unit, and attach the top cover for board D) instead.During attachment, remove D)’ with a nipper, etc. so that the connector of the board is exposed.

• Fix the top cover with an M3 screw E). (Tightening torque: 0.3 to 0.6 N m)

• When the FX1N-5DM is used also, refer to the Hardware manual offered with the FX1S/FX1N Series PLC main unit.

• Only one function expansion board is available for one FX1S/FX1N Series PLC basic unit. Never stack up two or more function expansion boards. (Even if they are stacked up, they do not function at all.)

• The 485BD can be used with the FX1N-EEPROM-8L only for program transfer.(The FX1N-EEPROM-8L cannnot be connected continuously.)

3. Specifications

3.1 Environmental specifications

The environmental specifications are equivalent to those of the PLC main unit. (Refer to the manual of thePLC main unit.)

3.2 Power supply specifications

5V DC, 20 mA is supplied as the power from the PLC.

Pin No. Signal Name Function

1 CDReceive carrier detection

Turns ON when carrier for data receive is detected.

2 RD(RXD)Receive data input

Receive data (RS-232C equipment → 232BD)

3 SD(TXD) Send data inputSend data (232BD → RS-232C equipment)

4 ER(DTR) Send requestTurns ON when RS-232C equipment becomes ready for receive.

5 SG(GND) Signal ground Signal ground

6 DR(DSR) Send enabledTurns ON when send request is given to RS-232C equipment

7,8,9 Not used

1

2

3

4

5

6

7

8

9

��

��

��

�����

��

��

�����

3.3 Performance specifications

Transmission standard In conformance to RS-232C

Maximum transmission distance

15 m (49ft) maximum

External equipment connection method

D-sub, 9-pin type (pin socket: manufactured by JST Mfg.) with JES-9P-2A3A (#4-40UNC, inch screw thread type)

D-sub 9-pin layout1: CD 2: RD(RXD) 3: SD(TXD) 4: ER(DTR) 5: SG(GND) 6: DR(DSR) 7, 8, 9: NC (not used)

Indication (LED) RXD, TXD

Communication method Half duplex, bi-directional

Communication procedure

Non-procedure, dedicated protocol 1 procedure, dedicated protocol 4 procedure, protocol for programming tool

Insulation Not insulated

Guidelines for the safety of the user and protection of the RS-232C Communica-tion Board FX1N-232-BD

• This manual has been written to be used by trained and competent personnel. This is definedby the European directives for machinery, low voltage and EMC.

• If in doubt at any stage during the installation of the RS-232C Communication Board FX1N-232-BD always consult a professional electrical engineer who is qualified and trained to the local andnational standards. If in doubt about the operation or use of the RS-232C Communication BoardFX1N-232-BD please consult the nearest Mitsubishi Electric distributor.

• Under no circumstances will Mitsubishi Electric be liable or responsible for any consequentialdamage that may arise as a result of the installation or use of this equipment.

• All examples and diagrams shown in this manual are intended only as an aid to understandingthe text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actualuse of the product based on these illustrative examples.

• Owing to the very great variety in possible application of this equipment, you must satisfyyourself as to its suitability for your specific application.

Manual number : JY992D84401

Manual revision : D

Date : October 2010

JY992D84401DEffective Oct. 2010Specifications are subject to change without notice

Attention

• This product is designed for use in industrial applications.

Note

• Manufactured by: Mitsubishi Electric Corporation2-7-3 Marunouchi, Chiyoda-ku, Tokyo, 100-8310 Japan

• Manufactured at: Mitsubishi Electric Corporation Himeji Works840 Chiyoda-machi, Himeji, Hyogo, 670-8677 Japan

• Authorized Representative in the European Community:Mitsubishi Electric Europe B.V.Gothaer Str. 8, 40880 Ratingen, Germany

Page 4: FX1N-232-BD - User's Guide JY992D84401-D (10.10)

This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.

HEAD OFFICEHIMEJI WORKS

: TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN : 840, CHIYODA CHO, HIMEJI, JAPAN

Side

A

Side

B JAPANESE ENGLISHSide

B

RS-232C COMMUNICATION BOARD FX1N-232-BD

USER’S GUIDE

JY992D84401D

This manual only describes the specifications for RS-232C Communication Board FX1N-232-BD.For complete operation, wiring, mounting and programming instructions please refer to the FX1S, FX1N

HARDWARE MANUAL and PROGRAMMING MANUAL.These manuals should be read and understood before attempting to install or use the unit.

Associated Manuals

1. Outline of Product

The RS-232C communication board FX1N-232-BD (hereafter referred to as "232BD") is connected to theFX1S/FX1N Series PLC basic unit, and available for the applications described below.

1.1 Features

1) Port to transfer the data using the non-procedure method between diversified RS-232C equipmentsuch as personal computer, bar code reader and printer

2) Port to transfer the data using a dedicated protocol between an RS-232C equipment

3) Port to connect a programming tool

1.2 Outside dimensions and name of each part

Manual name Manual No. Description

FX1S Series Hardware Manual

JY992D83901Describes contents related to hardware of FX1S Series PLC such as specifications, wiring and installation.

FX1N Series Hardware Manual

JY992D88201Describes contents related to hardware of FX1N Series PLC such as specifications, wiring and installation.

FX Programming Manual II

JY992D88101 Describes instructions in FX1S/FX1N/FX2N/FX2NC Series.

FX Series User's Manual - Data Communication Edition

JY997D16901Describes contents related to communication available in FX Series PLC such as wiring, communication setting and program examples. (Make sure to read this manual.)

��� ���

��������

�����

➁ ➆

Unit: mm (inches)

➀ Mounting hole (2-φ3.5)

➁ Connector for PLC

➂ RXD LED: Lit during receive.

➃ TXD LED: Lit during send.

➄ Connector for RS-232C equipment The top face of this connector is higher than the top face of thePLC panel cover by approximately 7 mm.

➅ Hole for connector fixing screw (#4-40UNC)Accessories:Top cover for board 1

M3 screw to mount board 2M3 screw to fix top cover 1

➆ Connector for display module FX1N-5DM or memory cassetteFX1N-EEPROM-8L

The communication connector of the 232BD is the D-sub, 9-pin socket type. The table below shows thepin arrangement.

1.3 System configuration

For the system configuration, refer to the FX Series User's Manual - Data Communication Edition offeredseparately.

2. Installation

2.1 Installation procedure

Make sure to turn off the power before installing the 232BD.

A) Communication board 232BD (function expansion board)

B) Connector for optional equipment

C) M3 screw to fix board (2 pieces) (offered as accessories of board)

D) Top cover for board (offered as an accessory of board)

E) M3 screw to fix top cover (offered as an accessory of board)

Note: Do not remove this screw of FX1S.

• Plug the communication board A) in to the connector B).

• Fix the board to the basic unit with two M3 screws C). (Tightening torque: 0.3 to 0.6 N m)

• Remove the top cover of the basic unit, and attach the top cover for board D) instead.During attachment, remove D)’ with a nipper, etc. so that the connector of the board is exposed.

• Fix the top cover with an M3 screw E). (Tightening torque: 0.3 to 0.6 N m)

• When the FX1N-5DM is used also, refer to the Hardware manual offered with the FX1S/FX1N Series PLC main unit.

• Only one function expansion board is available for one FX1S/FX1N Series PLC basic unit. Never stack up two or more function expansion boards. (Even if they are stacked up, they do not function at all.)

• The 485BD can be used with the FX1N-EEPROM-8L only for program transfer.(The FX1N-EEPROM-8L cannnot be connected continuously.)

3. Specifications

3.1 Environmental specifications

The environmental specifications are equivalent to those of the PLC main unit. (Refer to the manual of thePLC main unit.)

3.2 Power supply specifications

5V DC, 20 mA is supplied as the power from the PLC.

Pin No. Signal Name Function

1 CDReceive carrier detection

Turns ON when carrier for data receive is detected.

2 RD(RXD)Receive data input

Receive data (RS-232C equipment → 232BD)

3 SD(TXD) Send data inputSend data (232BD → RS-232C equipment)

4 ER(DTR) Send requestTurns ON when RS-232C equipment becomes ready for receive.

5 SG(GND) Signal ground Signal ground

6 DR(DSR) Send enabledTurns ON when send request is given to RS-232C equipment

7,8,9 Not used

1

2

3

4

5

6

7

8

9

��

��

��

�����

��

��

�����

3.3 Performance specifications

Transmission standard In conformance to RS-232C

Maximum transmission distance

15 m (49ft) maximum

External equipment connection method

D-sub, 9-pin type (pin socket: manufactured by JST Mfg.) with JES-9P-2A3A (#4-40UNC, inch screw thread type)

D-sub 9-pin layout1: CD 2: RD(RXD) 3: SD(TXD) 4: ER(DTR) 5: SG(GND) 6: DR(DSR) 7, 8, 9: NC (not used)

Indication (LED) RXD, TXD

Communication method Half duplex, bi-directional

Communication procedure

Non-procedure, dedicated protocol 1 procedure, dedicated protocol 4 procedure, protocol for programming tool

Insulation Not insulated

Guidelines for the safety of the user and protection of the RS-232C Communica-tion Board FX1N-232-BD

• This manual has been written to be used by trained and competent personnel. This is definedby the European directives for machinery, low voltage and EMC.

• If in doubt at any stage during the installation of the RS-232C Communication Board FX1N-232-BD always consult a professional electrical engineer who is qualified and trained to the local andnational standards. If in doubt about the operation or use of the RS-232C Communication BoardFX1N-232-BD please consult the nearest Mitsubishi Electric distributor.

• Under no circumstances will Mitsubishi Electric be liable or responsible for any consequentialdamage that may arise as a result of the installation or use of this equipment.

• All examples and diagrams shown in this manual are intended only as an aid to understandingthe text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actualuse of the product based on these illustrative examples.

• Owing to the very great variety in possible application of this equipment, you must satisfyyourself as to its suitability for your specific application.

Manual number : JY992D84401

Manual revision : D

Date : October 2010

JY992D84401DEffective Oct. 2010Specifications are subject to change without notice

Attention

• This product is designed for use in industrial applications.

Note

• Manufactured by: Mitsubishi Electric Corporation2-7-3 Marunouchi, Chiyoda-ku, Tokyo, 100-8310 Japan

• Manufactured at: Mitsubishi Electric Corporation Himeji Works840 Chiyoda-machi, Himeji, Hyogo, 670-8677 Japan

• Authorized Representative in the European Community:Mitsubishi Electric Europe B.V.Gothaer Str. 8, 40880 Ratingen, Germany