InstallationMake sure that the work surface is firm, steady and free from vibrationand draughts.

To avoid the risk of RSI (Repetitive Strain Injury) it is important toensure that the machine is placed on a surface which is ergonomicallysatisfactory to the user. In cases where usage is prolonged werecommend frequent breaks for the user.

Warnings

Cleaning the scale

For your protection, all mains (110V or 230V) equipment used wheredamp or wet conditions may occur, must be supplied from a correctlyfused source and protected by an approved RCD to BS7071 or BS7288or IEC1008-2-2 BS EN 61008:1995. IF IN DOUBT SEEK ADVICEFROM A QUALIFIED ELECTRICIAN.

To avoid the possibility of electric shock or damage to the machine,always isolate from the mains power supply before carrying out anyroutine maintenance.

Harsh abrasives, solvents, scouring cleaners and alkaline cleaningsolutions, such as washing soda, should not be used especially on thedisplay windows. Under no circumstances should you attempt to wipethe inside of the machine.

The outside of the machine may be wiped down with a clean clothmoistened with water containing a small amount of washing up liquid.

Product variations

Note: Depending on country, some functions may not be available; thelegend on some of the keys may also be different. For example:

Short press Short pressShort press Short press

Or Or

Page 3: FX 220 User Instructions - Armagh POS · FX 220 User Instructions Retail Price Computing Scale Brisch number 76102-649 Issue 2 07/06/01 ... by Avery Berkel in writing in each case

Error messagesIf a persistent error message appears, disconnect thenreconnect the scale to the power supply. If the scale remainsinoperative, contact your authorised service agent.

E 5 Disconnect then reconnect the scale to the power supply.E 10 Battery failure.E 11 Power supply voltage is too high.E 15 Contact your authorised service agent.E 20 Weight error.E 30 Invalid product configuration.E 35E 100 Invalid PLU contents (try re-programming the PLU).E 101 Transaction failed.E 102 PLU write failed.E 103 Tare failed.E 151 Product configuration memory failed.

Error codes:

Contact your authorised service agent.

E 152 User does not have access to this item (in management mode).

E 30

Temporaryerror

Weightunsteady

Balancefailed

Underrange

Overrange

Installing the head-up display optionUsing a flat-bladed screwdriver, remove the blanking plate from theback of the scale.

Carefully insert the plug from the display into the socket at theback of the scale. Replace the blanking plate.

Do not lift the scale by the head-up display or the weighplate.

Attach the display to the scale using the two slottedscrews.

Caution:

Page 4: FX 220 User Instructions - Armagh POS · FX 220 User Instructions Retail Price Computing Scale Brisch number 76102-649 Issue 2 07/06/01 ... by Avery Berkel in writing in each case

Switching on the scale

Connecting to the mains

Warning:

- Plug in the mains cable, replace thecover and weighplate then switch on using the mains ON/OFF switch.

Do not use the mains adaptor if it is damaged.

NiCad

Using batteries

Caution:

- Plug the battery pack into the scale and place thepack into the recess. Replace the cover and weighplate.

To avoid damage to the scale caused by leaking batteries,remove flat or damaged batteries immediately.

When you see the symbol flashing on the display, then you musteither replace the batteries (or recharge the rechargeable batteries).

Using a rechargeable battery pack

Recharging the battery pack

Note:

- Plug the rechargeablebattery pack into the scale and place the pack into the recess. Replacethe cover and weighplate.

- Plug in the mains cable to thebottom of the scale, then switch on using the mains ON/OFF switch.

You can still use the scale while the battery is being charged.

Page 5: FX 220 User Instructions - Armagh POS · FX 220 User Instructions Retail Price Computing Scale Brisch number 76102-649 Issue 2 07/06/01 ... by Avery Berkel in writing in each case

Bleeps

Short press (Press once) Long press (Press and hold)

Using the Clear keyTo clear the last number entered: To clear the entire entry:

Short press Long press

1,5720,260,40

1,5720,000,40

Selecting an alternate price base/Alternative units

00,0000,000,00

Short press

Testing the display/Selecting sleep mode

Short press

1101d0-6-0

Short press

X2Serviceinformation =

Wake up:

Long press Short press

SLEEP

Using the scale

Zeroing the scale - Make sure that the scale is at zero beforeweighing any goods.

Short press

00,0000,000,00

Weighing goods - Place the goods onto the scale and enter the unitprice.

Unit priceShort press

1,5720,260,40

Short press

Page 6: FX 220 User Instructions - Armagh POS · FX 220 User Instructions Retail Price Computing Scale Brisch number 76102-649 Issue 2 07/06/01 ... by Avery Berkel in writing in each case

Multiplying a unit price

Unit priceShort press

1,5720,260,40

1,5720,260,80

Short press Short press

Or

Retaining a unit price

To cancel aunit price:

Unit priceShort press

Repeat until all the goods have been weighed

Short press

Short pressLong press

1,5720,260,40

Item priceShort press

No of itemsShort press

Short press

Multiplying non-weighed items

Repeat until all the goods have been weighed

5

0,36Short press

Long press

Viewing the total Cancelng the total

5

1,80Short press Short press

Item priceShort press

Unit priceShort press

Repeat until all the goods have been weighed

Using the add key

6

1,36Short pressOr

Page 7: FX 220 User Instructions - Armagh POS · FX 220 User Instructions Retail Price Computing Scale Brisch number 76102-649 Issue 2 07/06/01 ... by Avery Berkel in writing in each case

Using tares

Semi-automatic tares

Retaining a tare

Cumulative tare

Keyboard entered tare

Proportional tare

For example, 33 = 3.3%, 205 = 20.5%

Short pressUnit priceShort press

1,5720,260,40

Short pressUnit priceShort press

Repeat until all the goods have been weighed

1,5720,260,40

Short pressUnit priceShort press

% tare X10Short press

1,5720,260,40

Short pressUnit priceShort press

Tare valueShort press

1,5720,260,40

To cancela retained tare:

Short press

Unit priceShort press

1,5720,260,40

Short press

Long press

Repeat until all the goods have been weighed

Short press

Page 8: FX 220 User Instructions - Armagh POS · FX 220 User Instructions Retail Price Computing Scale Brisch number 76102-649 Issue 2 07/06/01 ... by Avery Berkel in writing in each case

Programming a non-weighed PLU hot-keyAssign a unit price to the PLU

You will not be able to programme a PLU hot key if it has alreadybeen changed in management mode.Note:

Item priceShort press Long press

Programming a weighed goods PLU hot-keyAssign a tare to the PLU (if required)

Assign a unit price to the the PLU (if required) Select the PLU key:

Note: For some countries, the tare value canot be saved.

Short press

Or Or

% of tareShort press

Short press Short pressTare valueShort press

Unit priceShort press

Long press

Note: To programmePLUs 10 - 20 refer tomanagement mode.

Short press

Using PLUs

Using the PLU hot keys - For example, PLU .2

0,0000,260,00

Short press

1,5720,260,40

Short pressShort press Short press

1,5720,260,40

Using PLUs 1 - 9 - For example, PLU 7.

Short press Short pressShort press

1,5720,260,40

Using PLUs 10 - 20 - For example, PLU 12.

Page 9: FX 220 User Instructions - Armagh POS · FX 220 User Instructions Retail Price Computing Scale Brisch number 76102-649 Issue 2 07/06/01 ... by Avery Berkel in writing in each case

Navigating management mode

For example, turn the keyboard bleeper off and change the backlighttime to 5 seconds.

Note: Depending on country, some functions may not be available.

Branch Sub-branch

Value

19 .001

Branch ( )19

For Example:

Branch ( )20Sub-branch ( )00Sub-branch ( )01

Sub-branch ( )00

0 .000

19 .011

19 .001

19 .010

20 .004

20 .000

20 .001

Short pressLong press

Short pressShort press

Short pressShort press

Short press

Long press

Long press

Management mode

Entering management mode

Short press

Make a note of thisnumber, cut out andkeep in a safe place.

6 2 3 1Short press

Go to the next branch (long press)Go to next sub-branch (short press)

Go to the previous branch (long press)Go to previous sub-branch (short press)

CSelect value to be changed (short press)Return to Branch 00 (Long press)

Increment the value (short press)Increment the value X10 (long press)

Change the value (short press)After changing a value, you must

go to the next branch to accept the value.Note:

C Exit management mode

Page 10: FX 220 User Instructions - Armagh POS · FX 220 User Instructions Retail Price Computing Scale Brisch number 76102-649 Issue 2 07/06/01 ... by Avery Berkel in writing in each case

Switching the keyboard bleeper on/offGo to branch 19, sub-branch 01

0 = Off1 = On

19 .011

Error bleeperGo to branch 19, sub-branch 03

0 = Off1 = On

19 .031

Target bleepBranch 19, sub-branch 02 - Not applicable for this machine.

Changing the bleeper volumeGo to branch 19, sub-branch 04

0 = Quiet1 = Loud

19 .041

0 = always off1 = 5 seconds2 = 1 minute3 = 5 minutes4 = always on

20 .001

Changing the backlight timeGo to branch 20, sub-branch 00

0 = none1 = 1 minute2 = 5 minutes3 = 30 minutes

20 .011

Changing the sleep timeGo to branch 20, sub-branch 01

0 = Off1 = On

19 .001

Switching the bleeper alarm on/offGo to branch 19, Sub-branch 00

Page 11: FX 220 User Instructions - Armagh POS · FX 220 User Instructions Retail Price Computing Scale Brisch number 76102-649 Issue 2 07/06/01 ... by Avery Berkel in writing in each case

Changing the duration of a 'Long' pressGo to branch 29, sub-branch 00

29 .00200

Enter a value in units of 10 milliseconds (50 -255).For example :200 = 2 seconds150 = 1½ seconds100 = 1 second

Changing the default price baseGo to branch 61, sub-branch 00

0 = 100g1 = kg (lb)

61 .001

Changing a PLU unit priceGo to branch 100 + PLU number, sub-branch 00

You must now select the PLU price base.Note:

For example, PLU 05 Branch, 100 + 5 = 105

Unit price = 2.350 = No unit price

105 .00235

Short press

Changing a PLU tareGo to branch 100 + PLU number, sub-branch 01

Weighed tare: Keyboard entered tare:

For example, PLU 05 Branch, 100 + 5 = 105105 .0150

Short press

Or

Short press Short pressShort press

X2

Changing a PLU price baseGo to branch 100 + PLU number, sub-branch 03

For example, PLU 05 Branch, 100 + 5 = 105

4 = 100g5 = kg (lb)

105 .035

Page 12: FX 220 User Instructions - Armagh POS · FX 220 User Instructions Retail Price Computing Scale Brisch number 76102-649 Issue 2 07/06/01 ... by Avery Berkel in writing in each case

This document contains a general guide only of the product and shall not form any contract unless specifically agreedby Avery Berkel in writing in each case on the Order Acknowledgment. The specification of the products described

herein may vary from time to time and may be altered without notice.

Email: [email protected]@averyberkel.com

Internet: http://www.averyberkel.com

Changing a PLU proportional tareGo to branch 100 + PLU number, sub-branch 02

For example, PLU 05 Branch, 100 + 5 = 105

% tare X10, for example:33 = 3.3%205 = 20.5%

105 .0233