A complete line of packaged boilers (15 models) for efficient, quiet and safe operation for any commercial/industrial process application. Packaging - Processing Bid on Equipment 1-847-683-7720 www.bid-on-equipment.com Fulton Fulton Electric Steam Boilers From 12 to 1000 kW (1.2 to 100 BHP) Built/certified in accordance to ASME Boiler and Pressure Vessel Code. All Fulton Electric Steam Boilers are UL Approved. 1.2-15 BHP are CSA Approved.

Fulton - Bid on Equipmentbidonequipment.info/s/FULTON Electric Steam... · Unit 2 - 36 kW (3.6 BHP) 15 PSIG electric steam boiler with 3 kW electric steam superheater skid mounted

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

A complete line of packaged boilers (15 models) for efficient, quiet and safe operation for any commercial/industrial process application.

Packaging - Processing Bid on Equipment

1-847-683-7720 www.bid-on-equipment.com

Fulton Fulton Electric Steam Boilers From 12 to 1000 kW

(1.2 to 100 BHP)

•Built/certified in accordance to ASME Boiler and Pressure Vessel Code.

All Fulton Electric Steam Boilers are UL Approved.

1.2-15 BHP are CSA Approved.

Packaging - Processing

Bid on Equipment 1-847-683-7720

www.bid-on-equipment.com

4110

Fulton Electric Steam Boilers Are Efficient, Quiet, And Safe For Your Process Needs Fulton manufactures a complete line of electric steam boilers from 12 kW to 1000 kW (1.2 to 100 BHP) up to 300 PSI for heating and process applications.

are totally immersed in water and the pressure vessel is fully insulated. Radiation losses are minimal.With a carefully calculated heat to steam ratio, operating pressures are achieved quickly with maximum efficiency. Electric boilers have no wasted fuel going out the stack as

Stainless steel heating elements Fulton uses low watt density ele-ments* made of stainless steel. Stainless will not melt or anneal as easily as copper elements. The small 12 to 36 kW boilers use horizontally mounted elements at the bottom.

Packaging - Processing

Bid on Equipment 1-847-683-7720

www.bid-on-equipment.com

Fulton can custom build completely piped and wired skid mounted units.

50 to 1000 kW elements mount vertically Can be serviced and periodically maintained simply by unbolting the element(s) from the flanges in the top of the boiler's "head". Expansion and contraction of the top mounted elements cause scale to flake off and drop to the bottom of the boiler. Strategically located 3" x 4" handholes allow easy inspection and periodic clean-out maintenance.

Save valuable time and expenses in the field by ordering complete skid mounted units ready for power and water hook up at the sight Unit 1- 50 kW (5 BHP) 600 PSIG steam boiler with dual level controls, skid-mounted, pre-piped with feed system and tandem feed-water preheaters. This unit is used for steam injection for pharmaceutical crystallization process.

Unit 2 - 36 kW (3.6 BHP) 15 PSIG electric steam boiler with 3 kW electric steam superheater skid mounted and pre-piped with return system and chemical feed system. Explosion proof, Class 1, Group C, D DN 1. All controls, instrumentation by Fulton including single source power connection. This unit is used for manufacturing/steril-ization of surgical equipment.

The element(s) are easily accessible-permit quick removal for service or inspection. Heating element ther-mostats are optional.

Features and advantages n Nearly 100% efficient n Quiet, clean n No NOx emissions n Ideal choice where fossil fuels are not

available or where electricity rates are favorable

n Built to ASME Code and UL Approved n Vertical design requires minimal floor

space n Completely wired control panel box

located in front of the boiler. n Safe. Solid state relays. All wiring meets

NEC specifications. n Second (auxiliary) low water

water cut-off probe standard

Component Locations of the Fulton 12 to 1000 kW (1.2 to 100 BHP) Steam Boilers

50 to 200 kW (5 to 20 BHP) Elements are vertically mounted. All probes are mounted in the top of the boiler.

1. Pressure Vessel Is Built To ASME Code 5 Year Warranty

2 Electrical Control Panel Box Electric Heating Elements Low Water Cut Off Probe Second (Auxiliary) Low Water Cut Off Probe Pump "On" Probe Pump "Off" Probe Sight Glass Assembly

9 Operating Pressure Control High Limit Pressure Control w/ manual reset Steam Outlet Safety Valve

1? Steam Gauge Assembly Steam Pressure Gauge

i.. High Temperature Insulation Surrounds The Pressure Vessel Large (3" x 4") Easily Access Handholes Feedwater Shut Off Valve Blowdown Valve

1 o Water Bottle Assembly For 300 to 1000 kW only

Note: Al l Fulton Electric Steam Boilers have a second (auxiliary) low water cut-off probe.

to 36 I 2 to

Element(s) are horizontally mounted at the bottom of the pressure vessel. All probes are located in the top of the boiler.

Packaging - Proce g

Bid on Equipment 1-847-68131aNC1 Fulton Electric Steam Boilers Have a second (auxiliary) low water cut-off probe.

www.bid-on-equipment.com

• 300 to 1000 kW (30 to 1 r" BHP: Elements are vertically mounted. These boilers have an externally mounted water bottle assembly housing the low water cut-off probe, pump on probe and pump off probe.The second (auxiliary) low water cut off probe is mounted in the top of the boiler.

Packaging - Processing

Bid on Equipment 1-847-683-7720

www.bid-on-equipment.com

DimensionsModel FB-L 012 015 018 024 030 036 050 075 100 150 200 300 500 750 1000 Unit Size: kW

HP12 15 18 24 30 36 50 75 100 150 200 300 500 750 1000 1.2 1.5 1.8 2.4 3.0 3.5 5.0 7.5 10 15 20 30 50 75 100

Height (A) Boiler Overall IN

MM24 24 24 24 24 24 55 55 55 55 55 75 75 75 75

610 610 610 610 610 610 1397 1397 1397 1397 1397 1905 1905 1905 1905 (B) Boiler w/Piping IN

MM30 30 30 30 30 30 65 65 65 65 71 80 80 80 80 762 762 762 762 762 762 1651 1651 1651 1651 1803 2032 2032 2032 2032

(C) Feedwater Inlet IN MM

8 8 8 8 8 8 16 16 16 16 16 24 24 24 24 203 203 203 203 203 203 406 406 406 406 406 610 610 610 610

(D) Slowdown Outlet IN MM

4 4 4 4 4 4 6 6 6 6 6 6.5 6.5 6.5 6.5 102 102 102 102 102 102 152 152 152 152 152 165 165 165 165

(E) Electric Control Box IN MM

20.5 20.5 20.5 20.5 20.5 20.5 50 50 50 50 48 64 64 64 64 521 521 521 521 521 521 1270 1270 1270 1270 1219 1626 1626 1626 1626

(F) Hand Hole IN MM

11 11 11 11 11 11 38 38 38 38 38 55 55 55 55 279 279 279 279 279 279 965 965 965 965 965 1397 1397 1397 1397

Width & Depth (G) Boiler Only IN

MM20 20 20 20 20 20 17 24 24 28 32 36 44 50 63

508 508 508 508 508 508 432 610 610 711 813 914 1118 1270 1600 (H) Overall Depth Electric IN

Panel to Blowdown MM30 30 30 30 30 30 35 35 35 39 46 46 56 62 83 762 762 762 762 762 762 899 899 899 991 1168 1168 1442 1575 2108

(I) Electric Panel Width IN MM

14 14 14 14 14 14 17 17 32 32 40 52 64 64 64 356 356 356 356 356 356 432 432 813 813 1016 1321 1626 1626 1626

(J) Boiler Width Overall IN MM

33 33 33 33 33 33 35 42 42 46 52 56 64 72 91 838 838 838 838 838 838 889 1067 1067 1168 1321 1422 1625 1829 2311

Minimum Clearances (K) Horizontal IN

to remove elements MM14 14 14 14 14 14 - - - - - - - - -

356 356 356 356 356 356 - - - - - - - - -(L) Floor to Ceiling IN

to remove elements MM- - - - - - 95 95 95 95 95 139 139 139 139 - - - - - - 2413 2413 2413 2413 2413 3531 3531 3531 3531

(M) Front of Boiler IN MM

24 24 24 24 24 24 24 32 32 32 34 34 36 36 36 610 610 610 610 610 610 610 813 813 813 864 864 914 914 914

(N) Sides & Rear of Boiler IN

MM

12 12 12 12 12 12 12 12 12 12 24 24 24 24 24

305 305 305 305 305 305 305 305 305 305 610 610 610 610 610

Models Pb-L. 050-11 50 kW to 1000 kW (5-100 BHP)

Models L 01 16 12 to 36 kW (1 .2 to 3.6 BHP)

Packaging - Processing

Bid on Equipment 1-847-683-7720

www.bid-on-equipment.com

Dimensions are approximate. We reserve the right to change specifications. -Indicates not available. Panel Box size may change depending on voltage.

Packaging - Processing

Bid on Equipment 1-847-683-7720

www.bid-on-equipment.com 411,

Specifications Model FB-L 012 015 018 024 030 036 050 075 100 150 200 300 500 750 1000

Number of Elements 1 1 1 2 2 2 2 3 4 6 4 4 7 10 14 Output 1000 BTU/HR 41 51 61 82 102 123 171 256 341 512 683 1025 1708 2561 3416

1000 KCAL/HR 10 13 15 21 26 31 43 64 86 129 172 258 430 645 860 Steam Output** LB/HR 40 50 60 81 101 121 169 252 336 505 674 1011 1684 2526 3368

KG/HR 18 23 27 37 46 55 77 115 153 230 306 460 765 1148 1530 Approx. Shipping Weight LB 400 400 400 440 440 460 580 850 970 1223 1425 1440 1825 2150 2300

KG 182 182 182 200 200 209 263 386 440 556 648 655 830 977 1043 Water Capacity GALLONS 7 7 7 7 7 7 13 39 39 50 79 115 195 270 360

LITERS 26 26 26 26 26 26 49 148 148 189 299 435 738 1022 1362 Boiler Connection Sizes Steam Outlet 15 PSI IN .75 .75 .75 .75 .75 .75 1 1.5 1.5 2 3 3 4 4 6

MM 19 19 19 19 19 19 25 38 38 51 76 76 100 100 150 Steam Outlet 16-300 PSI IN 75 .75 .75 .75 .75 .75 .75 1 1 1.25 1.5 2 3 3 3

MM 19 19 19 19 19 19 19 25 25 32 38 51 76 76 76 Feedwater Inlet IN .75 .75 .75 .75 .75 .75 .75 .75 1 1 1 1 1 1 1.25

MM 19 19 19 19 19 19 19 19 25 25 25 25 25 25 32 Blowdown Outlet IN 1 1 1 1 1 1 1 1 1 1 1.25 1.25 1.5 1.5 2

MM 25 25 25 25 25 25 25 25 25 25 32 32 38 38 51 Water Col. Slowdown Outlet IN NA NA NA NA NA NA NA NA NA NA NA .75 .75 .75 75

MM - - - - - - - - - - - 19 19 19 19 Sight Glass Blowdown Outlet IN .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25 .25

MM 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Safety Valve 15 PSI IN .75 .75 .75 .75 .75 .75 1 1 1 1.25 1.50 1.5 1.5 2 2.5

MM 19 19 19 19 19 19 25 25 25 32 38 38 38 51 64 Safety Valve 16-300 PSI IN .50 .50 .50 .50 .50 .50 .75 .75 .75 .75 1 1 1.25 1.5 2

MM 13 13 13 13 13 13 19 19 19 19 25 25 32 38 51 Electrical Power Requirements (In Amps) 208V 3 Phase 34 42 50 67 84 100 139 208 278 416 556 832 * * *

230V 1 Phase 52 65 78 - - - - - - - - - - - -240V 3 Phase 29 36 43 58 73 87 120 180 241 361 482 724 * 480V 3Phase 15 18 21 29 36 44 60 90 120 180 241 363 607 906 1204 575V 3 Phase 13 16 18 24 30 36 50 76 101 150 201 301 502 756 1004

Dimensions are approximate. We reserve the right to change specifications. Probe liquid level control is standard on all units. Optional Water Level Controls Watts 142-5 McDonnell Miller 53-2 McDonnell Miller 47-2 McDonnell Miller 157 - 157M

Notes: -Indicates not available. * Indicates voltages available at special request. **Steam output ratings, at 180°F (82°C) feedwater temperature,(0 PSIG).

Standard Electrical Control Panel Components n Low Water Relay n Water Level Relay n High Limit Pressure Control Switch w/manual reset n Operating Pressure Control Element Contactor(s) Switch n Pump Starter (1 phase) n Power Switch n Power Lamp n Element Energized Lamp n CSD-1 Low Water Relay With Manual Reset (75 kW-1000kW)

Models FB-L 100 to FB-L 1000 include a step sequencer.