FUJI Low Voltage Distributionand Control Equipment

Page 2: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

Fuji Electric FA meets customer needs with a wide range of products and

Page number

2P 2P 6P

14P

10P 10P

13P

6P

10P

Combinationstarters

Power receiving

Motor load 1 Motor load 2 Motor load 3 Heaters

Vacuum circuitbreakers

Voltage transformers

Multi display lights

Voltmeters

Current transformers

Cast-resintransformers

Power monitoringequipment

10P

Semiconductorfuses

InvertersServo system

Solid statecontactors

Pushbuttons Selectors

Pilot lights

Air circuitbreakers

MCCBsELCBs

MCCBsELCBs

MCCBsELCBs

MCCBsELCBs

Manual motorstarters

Magnetic contactorsand starters

Magnetic contactorsand starters

Magneticcontactors

VCB

CT

T

VT

Page 3: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

solid reliability

CONTENTS

17P 18P

20P

Fuji Electric FA Components & Systems Co., Ltd. provides a wide range of component equipment and system products, such as power distribution, control, and drive control equipment, to support the operation and safety of factory FA lines, intelligent buildings, and other applications.

Capacitors

Surge protectivedevices

Panel switches

Protective relaysAmmeters

Terminal blocks

Current-limitingfuses

10P

Voltagetransformers

Magneticcontactors

for capacitorbank

Currenttransformers

2Magnetic Contactors and Starters

6Manual Motor Starters and Contactors

10Molded Case Circuit Breakers

13Air Circuit Breakers

Pushbuttons, Selectors, Pilot Lights14

Command Switches

17Time Delay Relays

18Industrial Control Relays

20Power Monitoring Unit

Industrialcontrol relays

Time delayrelays

MCCBsELCBs

Powermonitoring

unit

Page 4: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

2

Type ContactorStarter

Max. motor 200-240Vcapacity (kW) 380-440VAC-3 500-550VIEC 60947-4-1 600-660VOperational 200-240Vcurrent (A) 380-440V

500-550V600-660V

Thermal current (A)Auxiliary contact arrangement

Durability Electrical 200V( x 106 operations) 400V MechanicalSwitching cycle per hourThermal overload Standard typerelay

Phase-loss protectionSetting range (A)

Dimensions (mm) ContactorsW x H x D Starters Standard

SC-03SW-03/3H 2.5 4 4 411 9 7 5201NO1NC21.75101800TR-0N/3

TK-0N0.1-0.150.13-0.20.15-0.240.2-0.30.24-0.360.3-0.450.36-0.540.48-0.720.64-0.960.8-1.20.95-1.451.4-2.21.7-2.62.2-3.42.8-4.24-65-86-97-11

43 x 81 x 8044 x 122 x 80IEC 60947-4-1, EN60947-4-1, VDE0660, TÜV, CE mark, CSA C22.2, UL508, CCC, NK, LR, BV, KR

SC-0SW-0/3H 3.5 5.5 5.5 5.51312 9 7201NO1NC21.5101800TR-0N/3

TK-0N0.1-0.150.13-0.20.15-0.240.2-0.30.24-0.360.3-0.450.36-0.540.48-0.720.64-0.960.8-1.20.95-1.451.4-2.21.7-2.62.2-3.42.8-4.24-65-86-97-119-13

43 x 81 x 8044 x 122 x 80

SC-05SW-05/3H 3.5 5.5 5.5 5.51312 9 7201NO+1NC2NO, 2NC21.5101800TR-0N/3

TK-0N0.1-0.150.13-0.20.15-0.240.2-0.30.24-0.360.3-0.450.36-0.540.48-0.720.64-0.960.8-1.20.95-1.451.4-2.21.7-2.62.2-3.42.8-4.24-65-86-97-119-13

53 x 81 x 8053 x 122 x 80

SC-4-0SW-4-0/3H 4.5 7.5 7.5 7.5181613 9251NO1NC1.51101800TR-5-1N/3

TK-5-1N0.1-0.150.13-0.20.15-0.240.2-0.30.24-0.360.3-0.450.36-0.540.48-0.720.64-0.960.8-1.20.95-1.451.4-2.21.7-2.62.2-3.42.8-4.24-65-86-97-119-1312-18

53 x 81 x 8153 x 127 x 81

SC-4-1SW-4-1/3H 5.51111 7.5222217 9321NO1NC1.51101800TR-5-1N/3

TK-5-1N0.1-0.150.13-0.20.15-0.240.2-0.30.24-0.360.3-0.450.36-0.540.48-0.720.64-0.960.8-1.20.95-1.451.4-2.21.7-2.62.2-3.42.8-4.24-65-86-97-119-1312-1816-2253 x 81 x 8153 x 127 x 81

SC-5-1SW-5-1/3H 5.51111 7.5222217 9321NO+1NC, 2NO2NC, 2NO+2NC1.51101800TR-5-1N/3

TK-5-1N0.1-0.150.13-0.20.15-0.240.2-0.30.24-0.360.3-0.450.36-0.540.48-0.720.64-0.960.8-1.20.95-1.451.4-2.21.7-2.62.2-3.42.8-4.24-65-86-97-119-1312-1816-2264 x 81 x 8164 x 127 x 81

SC-N1SW-N1/3H 7.515151132322415502NO+2NC4NO+4NC1.51101200TR-N2/3

TK-N24-65-86-97-119-1312-1818-2624-36

74 x 87 x 9674 x 146 x 96

Standard type non-reversing, open 03 to N1

Controlling energy to manage motorsand machinery

SW-0SW-N5

Page 5: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

3

Type ContactorStarter

Max. motor 200-240Vcapacity (kW) 380-440VAC-3 500-550VIEC 60947-4-1 600-660VOperational 200-240Vcurrent (A) 380-440V

500-550V600-660V

Thermal current (A)Auxiliary contact arrangement

Durability Electrical 200V( x 106 operations) 400V MechanicalSwitching cycle per hourThermal overload Standard typerelay

Phase-loss protectionSetting range (A)

Dimensions (mm) ContactorsW x H x D Starters Standard

SC-N2SW-N2/3H1118.518.51540402919602NO+2NC4NO+4NC1.51101200TR-N2/3

TK-N24-65-86-97-119-1312-1818-2624-3632-42

74 x 87 x 9674 x 146 x 96IEC 60947-4-1, EN60947-4-1, VDE0660, TÜV, CE mark, CSA C22.2, UL508, CCC, NK, LR, BV, KR

SC-N2SSW-N2S/3H1522252250503826802NO+2NC4NO+4NC21.551200TR-N3/3

TK-N37-119-1312-1818-2624-3628-4034-5045-65

88 x 110 x 11188 x 177 x 111

SC-N3SW-N3/3H18.5303730656560381002NO+2NC4NO+4NC21.551200TR-N3/3

TK-N37-11 9-1312-1818-2624-3628-4034-5045-6548-6853-80 *65-95 *85-105 *88 x 110 x 11188 x 177 x 111

SC-N4SW-N4/3H22403737808060441352NO+2NC4NO+4NC10.851200TR-N5/3

TK-N518-2624-3628-4034-5045-6553-80

88 x 127 x 11788 x 189 x 117

SC-N5SW-N5/3H 30 55 55 55105105 85 641502NO+2NC4NO+4NC0.80.751200TR-N5/3

TK-N518-2624-3628-4034-5045-6553-8065-9585-105

88 x 127 x 13288 x 189 x 132

SC-N6SW-N6/3H 37 60 60 60125125 90 721502NO+2NC4NO+4NC0.60.551200TR-N6/3

TK-N645-6553-8065-9585-125110-160 *

100 x 144 x 138100 x 225 x 138

SC-N7SW-N7/3H 45 75 75 901501501201032002NO+2NC4NO+4NC10.851200TR-N7/3

TK-N745-6553-8065-9585-125110-160

115 x 156 x 140155 x 237 x 140

Note: * Separate mounting only

Type ContactorStarter

Max. motor 200-240Vcapacity (kW) 380-440VAC-3 500-550VIEC 60947-4-1 600-660VOperational 200-240Vcurrent (A) 380-440V

500-550V600-660V

Thermal current (A)Auxiliary contact arrangement

Durability Electrical 200V( x 106 operations) 400V MechanicalSwitching cycle per hourThermal overload Standard typerelay

Phase-loss protectionSetting range (A)

Dimensions (mm) ContactorsW x H x D Starters Standard

SC-N8SW-N8/3H 55 901301321801801801502602NO+2NC4NO+4NC10.851200TR-N8/3

TK-N865-9585-125110-160125-185

138 x 209 x 174138 x 305 x 174IEC 60947-4-1, EN60947-4-1, VDE0660, TÜV, CE mark, CSA C22.2, UL508, CCC, NK, LR, BV, KR

SC-N10SW-N10/3H 651101321322202202001502602NO+2NC4NO+4NC10.851200TR-N10/3

TK-N1085-125110-160125-185160-240

138 x 209 x 174138 x 287 x 174

SC-N11SW-N11/3H 901601602003003002302303502NO+2NC4NO+4NC10.851200TR-N12/3

TK-N12110-160125-185160-240200-300

148 x 240 x 195148 x 360 x 195

SC-N12SW-N12/3H1202202503004004003603604502NO+2NC4NO+4NC0.70.651200TR-N12/3

TK-N12110-160125-185160-240200-300240-360300-450148 x 240 x 195148 x 360 x 195

SC-N14SW-N14/3H1803154004806006006006006602NO+2NC4NO+4NC0.60.551200TR-N14/3

TK-N14240-360300-450400-600

290 x 332 x 327290 x 463 x 327

SC-N16–2204405005008008007206308002NO+2NC4NO+4NC0.30.252.51200–

––

290 x 332 x 327–

Standard type non-reversing, open N2 to N7

Standard type non-reversing, open N8 to N16

Page 6: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

4

Optional unit

Type

Used with

Auxiliary contact block

All contacts are bifurcated contacts so that the minimum voltage current is 5V DC, 3mA.

4-poleSZ-AFront mounting

SC-03 to N3

Operation counter

This unit indicates the number of contactor on-off operations to ensure easy maintenance and inspection.

Coil surge suppression unitThis unit absorbs coil surge voltage due to contactor on-off operation.

Main circuit surge suppression unitThis unit prevents misoperation of electronic equipment due to surge voltage generated from motor when contactor is open or closed.

SZ-J

SC-03 to N3

SZ-Z

SC-03 to N4SC-03/G to SC-N3/G

SZ-ZMFront mounting

SC-03 to N3SC-03 to N3

2-poleSZ-A

Single-poleSZ-ASSide mounting

Side mounting

SC-03 to N16

Optional unit

Type

Used with

Mechanical interlock unit and power connection kit for reversing

This unit is used to interlock two contactors for reversing.

SZ-RM

SC-03 to N3

Coil drive unit for IC output

This unit controls on-off operation for contactor by the DC output of electronic equipment.

3-pole parallel connection kit

This kit modifies a 3-pole contactors to a single-pole contactor for resistive load.

SZ-CDTop mounting

SC-03 to N3

SZ-CDSide mounting

SC-N1 to N12

SZ-SP

SC-03 to N16

Base unit for separate mounting

This unit is used when thermal relay is required to mount independently.

SZ-H

TR-0N to N3

Dial cover

For protection against the current setting being changed in error.SZ-DA

TR-0N to N14

SZ-RW

SC-03 to N3

Optional unit

Type

Used with

Trip indicator

This unit indicates thermal relay tripping status.

SZ-L

TR-0N to N14

Terminal cover

This covers conform to DIN 57106 and VDE 0106 Teil 100.

Insulation barrier

This unit prevents accidental short-circuits caused by metallic objects falling onto the terminals.

SZ-T , T,SZ-W T

SC-03 to N12SW-03 to N12

TR-0N to N3TR-N2H, N3H, N6H

SZ-B

SC-N4 to N12SW-N4 to N12TR-N6H, N10H, N12H

Live-section cover

This cover prevents exposure of the live section for increasing safety.

SZ- J, W J SZ-J , JW

SC-03 to N12SW-03 to N12

Off-delay release unit

This unit prevents circuit opening due to instantaneous voltage drop.

SZ-DE SZ- DE

SC-03/G to N14

Optional accessories

Page 7: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

5

Max. motor capacity (kW)Single-phase110V0.40.50.50.60.80.8

1.21.7–––––––Coil voltage *• SW-03P to 5-1P, N1PB to N4PB24V 50Hz / 24-26V 60Hz48V 50Hz / 48-52V 60Hz100V 50Hz / 100-110V 60Hz100-110V 50Hz / 110-120V 60Hz110-120V 50Hz / 120-130V 60Hz200V 50Hz / 200-220V 60Hz200-220V 50Hz / 220-240V 60Hz220-240V 50Hz / 240-260V 60Hz346-380V 50Hz / 380-420V 60Hz380-400V 50Hz / 400-440V 60Hz415-440V 50Hz / 440-480V 60Hz480-500V 50Hz / 500-550V 60Hz

Auxiliary contact

Standard1NO1NO1NO+1NC1NO1NO1NO+1NC

2NO+2NC2NO+2NC2NO+2NC2NO+2NC2NO+2NC2NO+2NC2NO+2NC2NO+2NC2NO+2NC

• SW-N5PB to N10PBAC24-25V 50/60Hz48-50V 50/60Hz100-127V 50/60Hz200-250V 50/60Hz265-347V 50/60Hz380-450V 50/60Hz460-575V 50/60Hz

With on-off/reset pushbuttonTypeSW-03P/3HSW-0P/3HSW-05P/3HSW-4-0P/3HSW-4-1P/3HSW-5-1P/3H

SW-N1PB/3HSW-N2PB/3HSW-N2SPB/3HSW-N3PB/3HSW-N4PB/3HSW-N5PB/3HSW-N6PB/3HSW-N8PB/3HSW-N10PB/3H

3-phase200/240V

2.53.53.54.55.55.5

7.5111518.52230375565

380/440V45.55.57.5

1111

1518.5223040556090

110

• Compact and simple operation – Provided with ON-OFF and reset pushbuttons, hence best suited for direct-on-line starting.

• Superior motor protection – Built-in highly reliable thermal overload relay is designed to give motor complete protection against overcurrent.

• Long service life – Hyperfine silver alloy contacts performance and a long electrical life.

Starters with on-off and RESET pushbuttons

* Other coil voltages between 24V and 600V AC are available.

DC24V48V100-120V200-240V

Motor capacity (kW)AC-3 3-phase200/240V

33.55.57.5

111518.51.53.03.53.03.53.03.51.5

Coil voltage *• FC-0/UL to 4UL24V 50Hz / 24-26V 60Hz48V 50Hz / 48-52V 60Hz100V 50Hz / 100-110V 60Hz100-110V 50Hz / 110-120V 60Hz110-120V 50Hz / 120-130V 60Hz200V 50Hz / 200-220V 60Hz200-220V 50Hz / 220-240V 60Hz220-240V 50Hz / 240-260V 60Hz346-380V 50Hz / 380-420V 60Hz380-400V 50Hz / 400-440V 60Hz415-440V 50Hz / 440-480V 60Hz

Operationalcurrent (A)AC-1202030304060808

2020202020208

Auxiliary contact

Standard1NO, 1NC1NO, 1NC1NO+1NC *1

1NO+1NC *1

1NO+1NC *1

1NO+1NC *1

1NO+1NC *1

1NO, 1NC1NO, 1NC1NO, 1NC1NO, 1NC1NO, 1NC1NO, 1NC1NO, 1NC1NO, 1NC

• FC-0/GUL to 0A/G24V DC48V DC60V DC100V DC110V DC200V DC220V DC

Non-reversing Open TypeFC-0ULFC-0SULFC-1ULFC-1SULFC-2SULFC-3ULFC-4ULFC-0AFC-0TULFC-0STULFC-0/GULFC-0S/GULFC-0/TGULFC-0S/TGULFC-0A/G

380/440V2.54.55.57.5

1118.530

–2.54.52.54.52.54.5

• Small size, light weight • Budget priced• Long service life – The contacts are self-cleaning by

a scrubbing section during operation and are made of silver alloy.

• Highly reliable operating coil – Pick up voltage 75% of rated voltage • Self-lifting terminals make it easy to wire.

Definite purpose contactors and starters

*1 : Auxiliary contact arrangement 2NO or 2NC is available.* Other coil voltages between 24V and 440V AC are available.

Type

ContactRated thermal current (A)

Make and break 110V ACcapacity (A) 220V AC

440V AC550V AC

Rated operationalcurrent (A) 110V AC

220V AC440V AC550V AC 24V DC 48V DC110V DC220V DC

Coil voltage *

Contact arrangement

SH-44-pole, 8-poleBifurcated10

60301512Ind.631.51.231.50.550.2724V 50Hz / 24-26V / 60Hz,48V 50Hz / 48-52V / 60Hz,100V 50Hz / 100-110V / 60Hz,110-120V 50Hz / 120-130V / 60Hz,200V 50Hz / 200-220V / 60Hz4-pole : 4NO, 3NO+1NC, 2NO+2NC8-pole : 8NO, 7NO+1NC, 6NO+2NC, 5NO+3NC, 4NO+4NC5-pole : 5NO, 4NO+1NC, 3NO+2NC, 2NO+3NC, 1NO+4NC, 5NC

SH-55-pole

Res.10 8 5 5 5 3 2.5 1

SH-5H5-pole

Res.1010101010 5 4 1

SH-4H4-pole, 8-poleSingle10

60604040Ind.664451.50.70.27220-240V 50Hz / 240-260V / 60Hz,346-380V 50Hz / 380-420V / 60Hz,380-400V 50Hz / 400-440V / 60Hz,415-440V 50Hz / 440-480V / 60Hz,480-500V 50Hz / 500-550V / 60Hz

• Employing of bifurcated contact assures an increase of high contact reliability in low-level circuit use (5V, 3mA)

• Variety of optional function units: Auxiliary contact block, off-delay release unit, coil surge suppression unit and operation counter

• Snap-on 35mm rail mounting available • UL, CSA, TÜV, BV and Lloyd approved

Standard type industrial relay

* Other coil voltages between 24V and 600V AC are available.

Versions

See page 01/1 of D & C catalog 19th Edition.Further Information

Page 8: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

6

Standard breaking capacityBM3RSB- BM3RSBK-

P16P25P40P630011P62P50046P3010013016020025032040050063

0.1-0.160.16-0.250.25-0.4 0.4-0.630.63-1 1-1.61.6-2.52.5-4 4-6.3 6.3-10 9-1311-1614-2019-2524-3228-4035-5045-63

3Rocker0.16 to 32200 to 69050/606906Category AAC-31013 x le maximum7W: In=0.16 to 25A 8.5W: In=32AMechanical 100,000: In=0.16 to 25A 70,000: In=32A Electrical 100,000: In=0.16 to 25A 70,000: In=32A25ProvidedProvided

45 x 90 x 66 45 x 90 x 79IEC 60947-1, 60947-2, 60947-4-1, UL 508, CSA C22.2 No.14, TÜV, CCC

Dimensions (mm) W x H x DStandard

Number of polesHandle typeRated current Ie (A)Rated operational voltage Ue (V)Rated frequency (Hz)Rated insulation voltage Ui (V)Rated impulse withstand voltage Uimp (kV)Utilization IEC 60947-2 Circuit breakercategory IEC 60947-4-1 Motor starterTrip class IEC 60947-4-1 *Instantaneous trip characteristicPower loss (total of 3-pole)Durability (operations)Max. operations per hour (motor start-up)Phase-loss protectionTrip indicator / Test trip functionRated breakingcapacity (kA)

IEC 60947-2

Replace the mark in the type number by current range codes.

Adjustable thermal-magnetic trip type Instantaneous trip type

3Rotary

High breaking capacityBM3RHB- BM3RHBK-

240V/230VIcu Ics100 100100 100100 100100 100100 100100 100100 100100 100100 100100 100100 100100 100 50 38 50 38 50 38–––

415V/400VIcu Ics100 100100 100100 100100 100100 100100 100100 100100 100100 100100 100 50 38 25 19 25 19 25 19 25 19–––

460V/440VIcu Ics100 100100 100100 100100 100100 100100 100100 100100 100 50 38 15 11 10 8 10 8 10 8 10 8 10 8–––

500V

Icu Ics100 100100 100100 100100 100100 100100 100100 100100 100 50 38 10 8 6 5 6 5 6 5 6 5 6 5–––

690V/600VIcu Ics100 100100 100100 100100 100100 100100 100 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2–––

240V/230VIcu Ics100 100100 100100 100100 100100 100100 100100 100100 100100 100100 100100 100100 100100 100100 100100 100–––

415V/400VIcu Ics100 100100 100100 100100 100100 100100 100100 100100 100100 100100 100100 100 50 38 50 38 50 38 50 38–––

460V/440VIcu Ics100 100100 100100 100100 100100 100100 100100 100100 100100 100 50 38 50 37 35 27 35 27 35 27 35 27–––

500V

Icu Ics100 100100 100100 100100 100100 100100 100100 100100 100100 100 50 38 42 32 10 8 10 8 10 8 10 8–––

690V/600VIcu Ics100 100100 100100 100100 100100 100100 100 8 6 8 6 6 5 6 5 6 5 4 3 4 3 4 3 4 3–––

Note: * Adjustable thermal-magnetic tirp type only

Adjustable current rangeCode Ie: Min.–Max. (A)

MMSs / 32AF

Molded case circuit breaker and thermaloverload relay functions integrated intohighly compact unit

DUO series

Page 9: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

7

MMSs / 63AF

Standard breaking capacityBM3VSB- BM3VSBK-

P16P25P40P630011P62P50046P3010013016020025032040050063

0.1-0.160.16-0.250.25-0.4 0.4-0.630.63-1 1-1.61.6-2.52.5-4 4-6.3 6.3-10 9-1311-1614-2019-2524-3228-4035-5045-63

3Rotary10 to 63200 to 69050/6010008Category AAC-31013 x le maximum11W: In=10 to 32A 15W: In=40 to 50A 17W: In=63AMechanical 50,000 Electrical 25,00025ProvidedProvided

55 x 110 x 96IEC 60947-1, 60947-2, 60947-4-1, UL 508, CSA C22.2 No.14, TÜV, CCC

Dimensions (mm) W x H x DStandard

Number of polesHandle typeRated current Ie (A)Rated operational voltage Ue (V)Rated frequency (Hz)Rated insulation voltage Ui (V)Rated impulse withstand voltage Uimp (kV)Utilization IEC 60947-2 Circuit breakercategory IEC 60947-4-1 Motor starterTrip class IEC 60947-4-1 *Instantaneous trip characteristicPower loss (total of 3-pole)Durability (operations)Max. operations per hour (motor start-up)Phase-loss protectionTrip indicator / Test trip functionRated breakingcapacity (kA)

IEC 60947-2

Replace the mark in the type number by current range codes.

Adjustable thermal-magnetic trip type Instantaneous trip type

3Rotary

High breaking capacityBM3VHB- BM3VHBK-

240V/230VIcu Ics– – – – – – – – – 100 100100 100100 100 50 38 50 38 50 38 50 38 50 38 50 38

415V/400VIcu Ics– – – – – – – – – 100 100 50 38 25 19 25 19 25 19 25 19 25 19 25 19 25 19

460V/440VIcu Ics– – – – – – – – – 15 1210 810 810 810 810 810 810 810 8

500V

Icu–––––––––10 6 6 6 6 6 6 6 6

690V/600VIcu–––––––––444444444

240V/230VIcu–––––––––100100100100100100100100100

415V/400VIcu–––––––––100100 50 50 50 50 50 50 50

460V/440VIcu–––––––––505050503535353535

500V

Icu–––––––––504212121210101010

690V/600VIcu–––––––––665555555

Note: * Adjustable thermal-magnetic tirp type only

Adjustable current rangeCode Ie: Min.–Max. (A)

Ics

855555555

Ics

333333333

Ics

100100100100100100100100100

Ics

100100 38 38 38 38 38 38 38

Ics

383838382727272727

Ics

3832 9 9 9 8 8 8 8

Ics

554444444

Page 10: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

8

Contactor Non-reversingReversing

Motor capacity 3-phase AC-3 (kW) 200-240V380-440V

Rated operational current AC-3 (A)200-240V380-440V

Rated thermal current AC-1 (A)Auxiliary contact Non-reversingDimensions (mm) W x H x D AC operatedNon-reversing DC operatedStandardThermal overload relay(standard type) Ampere setting range (A)

Dimensions W x H x D (mm)Standard

Contactor Non-reversing ReversingMotor capacity 3-phase AC-3 (kW)

200-240V380-440V

Rated operational current AC-3 (A)200-240V380-440V

Rated thermal current AC-1 (A)Auxiliary contact Non-reversingDimensions (mm) W x H x D AC operatedNon-reversing DC operatedStandardThermal overload relay(standard type) Ampere setting range (A)

Dimensions W x H x D (mm)Standard

SC-M01SC-M01RM

1.52.2

66

201NO, 1NC45 x 48 x 5645 x 48 x 68IEC 60947-4-1, EN 60947-4-1, VDE 0660, UL 508, CSA C22.2TK-M0

0.11-0.170.17-0.260.26-0.430.43-0.650.65-1.00.85-1.31.1-1.61.35-2.01.7-2.42.2-3.22.5-4.03.0-4.74.0-6.3

45 x 68.5 x 53IEC 60947-1, EN 60947-4-1, VDE 0660, UL 508, CSA C22.2

SC-E2SC-E2RM

1118.5

404060–54 x 90 x 9654 x 90 x 121.5IEC 60947-4-1, EN 60947-4-1, VDE 0660, UL 508, CSA C22.2TK-E2

4-65-86-97-119-1312-1818-2624-3632-42

54 x 78.5 x 97IEC 60947-1, EN 60947-4-1, VDE 0660, UL 508, CSA C22.2

SC-E2SSC-E2SRM

1522

505065–

TK-E2

4-65-86-97-119-1312-1818-2624-3632-4240-5044-54

SC-E3SC-E3RM

18.530

6865100–67 x 112 x 11167 x 112 x 130

TK-E3

7-119-1312-1818-2624-3628-4034-5045-6548-68

68 x 89.5 x 107.5

SC-E4SC-E4RM

2240

8080105–

TK-E3

7-119-1312-1818-2624-3628-4034-5045-6548-6864-80

76.5 x 105 x 106

SC-E5SC-E5RM

3055

1051051502NO+2NC88 x 155 x 132

TK-E5

18-2624-3628-4034-5045-6565-9585-105

100 x 122 x 123

SC-E6SC-E6RM

3760

1251251502NO+2NC100 x 169 x 138

TK-E6

45-6553-8065-9585-125

SC-E7SC-E7RM

4575

1501502002NO+2NC115 x 175 x 140

TK-E6

45-6553-8065-9585-125110-160

SC-E02SC-E02RM

2.24

99

20–43 x 81 x 8143 x 81 x 108

TK-E02

0.1-0.150.13-0.20.15-0.240.2-0.30.24-0.360.3-0.450.36-0.540.48-0.720.64-0.960.8-1.20.95-1.451.4-2.21.7-2.62.2-3.42.8-4.24-65-86-97-11

53 x 60.5 x 80.5

SC-E03SC-E03RM

35.5

121220–

TK-E02

0.1-0.150.13-0.20.15-0.240.2-0.30.24-0.360.3-0.450.36-0.540.48-0.720.64-0.960.8-1.20.95-1.451.4-2.21.7-2.62.2-3.42.8-4.24-65-86-97-119-13

SC-E04SC-E04RM

47.5

181825–

TK-E02

0.1-0.150.13-0.20.15-0.240.2-0.30.24-0.360.3-0.450.36-0.540.48-0.720.64-0.960.8-1.20.95-1.451.4-2.21.7-2.62.2-3.42.8-4.24-65-86-97-119-1312-18

SC-E05SC-E05RM

5.511

252532–

TK-E02

0.1-0.150.13-0.20.15-0.240.2-0.30.24-0.360.3-0.450.36-0.540.48-0.720.64-0.960.8-1.20.95-1.451.4-2.21.7-2.62.2-3.42.8-4.24-65-86-97-119-1312-1816-2220-25

SC-E1SC-E1RM

7.515

323250–54 x 90 x 9654 x 90 x 121.5

TK-E2

4-65-86-97-119-1312-1818-2624-36

54 x 78.5 x 97

SC-M02SC-M02RM

34

99

201NO, 1NC

TK-M0

0.11-0.170.17-0.260.26-0.430.43-0.650.65-1.00.85-1.31.1-1.61.35-2.01.7-2.42.2-3.22.5-4.03.0-4.74.0-6.35.5-8.07.5-10.5

Contactors / SC-M, SC-E

Page 11: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

9

Protective coordination between MMSs and contactors (Individuation)IEC 60947-4-1 Type 1 The rated conditional short-circuit current Iq=50kA/240V AC, 415V AC

Note: • The full-load current of each three-phase motor is a reference value. Check the actual full-load current of the motor before use.

Motor capacity and full load current3-phase200-240V ACCapacity(kW)0.030.06–0.12–0.25–0.37–0.75–1.52.2345.57.5

1115

Manual motor starterType

BM3RSB-P25BM3RSB-P40BM3RSB-P63BM3RSB-001BM3RSB-001BM3RSB-1P6BM3RSB-1P6BM3RSB-2P5BM3RSB-004BM3RSB-004BM3RSB-6P3BM3RSB-010BM3RSB-010BM3RSB-013BM3RHB-020BM3RHB-025BM3RHB-032BM3VHB-032BM3VHB-040BM3VHB-050

Magnetic contactorType

M seriesSC-M01SC-M01SC-M01SC-M01SC-M01SC-M01SC-M01SC-M01SC-M01SC-M01SC-M01SC-M02SC-M02

M series6666666666699

E series 9 9 9 9 9 9 9 9 9 9 9 9 912182532

4050

E seriesSC-E02SC-E02SC-E02SC-E02SC-E02SC-E02SC-E02SC-E02SC-E02SC-E02SC-E02SC-E02SC-E02SC-E03SC-E04SC-E05SC-E1

SC-E2SC-E2S

SC seriesSC-03SC-03SC-03SC-03SC-03SC-03SC-03SC-03SC-03SC-03SC-03SC-03SC-03SC-0 or SC-05SC-4-0SC-4-1 or SC-5-1SC-N1

SC-N2SC-N2S

SC series 9 9 9 9 9 9 9 9 9 9 9 9 912162232

4050

Rated operational currentAC-3 (A)

Adjustablecurrent range (A)

0.16 to 0.250.25 to 0.40.4 to 0.630.63 to 1.00.63 to 1.01.0 to 1.61.0 to 1.61.6 to 2.52.5 to 4.02.5 to 4.04.0 to 6.36.3 to 106.3 to 109 to 1314 to 2019 to 2524 to 32

28 to 4035 to 50

Current(A)0.240.37–0.72–1.4–2–3.6–6.19.212162229

3850

380-415V ACCapacity(kW)0.060.090.180.180.250.370.550.751.11.52.2345.57.51115

18.522

Current(A)0.210.310.630.630.81.11.51.92.53.44.56.5811142128

3545

Protective coordination between MMSs and contactors (Combination starters)IEC 60947-4-1 Type 1 The rated conditional short-circuit current Iq=50kA/240V AC, 415V AC

Notes: • The full-load current of each three-phase motor is a reference value. Check the actual full-load current of the motor before use.• The above table shows combinations with AC operated type magnetic contactors. The link module will differ if the magnetic contactor is a DC operated type.*1 Use the base plate type in ( ) when you use the base plate.

Motor capacity and full load current3-phase200-240V ACCapacity(kW)0.03

0.06

0.12

0.25

0.37

0.75

1.5

2.2

345.57.5

1115

Manual motor starterType

BM3RSB-P25

BM3RSB-P40

BM3RSB-P63

BM3RSB-001

BM3RSB-001

BM3RSB-1P6

BM3RSB-1P6

BM3RSB-2P5

BM3RSB-004

BM3RSB-004

BM3RSB-6P3

BM3RSB-010

BM3RSB-010

BM3RSB-013BM3RHB-020BM3RHB-025BM3RHB-032BM3VHB-032BM3VHB-040BM3VHB-050

Magnetic contactor Type

SC-M01SC-E02SC-M01SC-E02 SC-M01SC-E02 SC-M01SC-E02 SC-M01SC-E02 SC-M01SC-E02 SC-M01SC-E02 SC-M01SC-E02 SC-M01SC-E02 SC-M01SC-E02 SC-M01SC-E02 SC-M02SC-E02 SC-M02SC-E02 SC-E03SC-E04SC-E05SC-E1

SC-E2SC-E2S

Link module

BZ0LRC09AA BZ0LRE22AA BZ0LRC09AA BZ0LRE22AA BZ0LRC09AA BZ0LRE22AA BZ0LRC09AA BZ0LRE22AA BZ0LRC09AA BZ0LRE22AA BZ0LRC09AA BZ0LRE22AA BZ0LRC09AA BZ0LRE22AA BZ0LRC09AA BZ0LRE22AA BZ0LRC09AA BZ0LRE22AA BZ0LRC09AA BZ0LRE22AA BZ0LRC09AA BZ0LRE22AA BZ0LRC09AA BZ0LRE22AA BZ0LRC09AA BZ0LRE22AA BZ0LRE22AA BZ0LRE22AA BZ0LRE22AA BZ0LRE32AA BZ0LVE51AA BZ0LVE51AA BZ0LVE51AA

Base plate

*1

(BZ0BPRE22A) BZ0BPRE22A (BZ0BPRE22A) BZ0BPRE22A (BZ0BPRE22A) BZ0BPRE22A (BZ0BPRE22A) BZ0BPRE22A (BZ0BPRE22A) BZ0BPRE22A (BZ0BPRE22A) BZ0BPRE22A (BZ0BPRE22A) BZ0BPRE22A (BZ0BPRE22A) BZ0BPRE22A (BZ0BPRE22A) BZ0BPRE22A (BZ0BPRE22A) BZ0BPRE22A (BZ0BPRE22A) BZ0BPRE22A (BZ0BPRE22A) BZ0BPRE22A (BZ0BPRE22A) BZ0BPRE22A BZ0BPRE22A BZ0BPRE22A BZ0BPRE22A BZ0BPRE32A BZ0BPV51A BZ0BPV51A BZ0BPV51A

Rated operational current (AC-3) (A)

6 9 6 9 6 9 6 9 6 9 6 9 6 9 6 9 6 9 6 9 6 9 9 9 9 912182532

4050

Adjustablecurrent range(A)

0.16 to 0.25

0.25 to 0.4

0.4 to 0.63

0.63 to 1.0

0.63 to 1.0

1.0 to 1.6

1.0 to 1.6

1.6 to 2.5

2.5 to 4.0

2.5 to 4.0

4.0 to 6.3

6.3 to 10

6.3 to 10

9 to 1314 to 2019 to 2524 to 32

28 to 4035 to 50

Current(A)0.24

0.37

0.72

1.4

2

3.6

6.1

9.2

12162229

3850

380-415V ACCapacity(kW)0.06

0.09

0.18

0.18

0.25

0.37

0.55

0.75

1.1

1.5

2.2

3

4

5.57.51115

18.522

Current(A)0.21

0.31

0.63

0.63

0.8

1.1

1.5

1.9

2.5

3.4

4.5

6.5

8

11142128

3545

See page 02/1 of D & C catalog 19th Edition.Further Information

Page 12: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

10

BW series/2, 3-pole

E series/2, 3-pole

FramePoleTypeRated current (A)

Rated interrupting 415V ACcapacity (kA) 380V ACIEC 60947-2 (Icu/Ics) 230V AC

100A3BW103E015, 20, 25, 30 40, 50, 60, 75 80,10015/818/925/13

160A2BW162E0100, 125, 150, 160

18/918/925/13

3BW163E0

250A2BW252E0175, 200, 225, 250

18/918/925/13

3BW253E0

100A2BW102S015, 20, 25, 30, 40, 50, 60, 75 80, 100

30/830/1550/25

3BW103S0

30/830/15100/50

FramePoleTypeRated current (A)Rated interrupting 415V ACcapacity (kA) 380V ACIEC 60947-2 (Icu/Ics) 230V AC

160A2BW162J0100, 125, 150, 16025/1325/1350/25

3BW163J0

2BW162S0100, 125, 150, 16036/1836/1885/43

3BW163S0

3BW253J0

2BW252S0175, 200, 225, 25036/1836/1885/43

3BW253S0

250A2BW252J0175, 200, 225, 25025/1325/1350/25

FramePoleTypeRated current (A)Rated interrupting 415V ACcapacity (kA) 380V ACIEC 60947-2 (Icu/Ics) 230V AC

30A2EA32AC -CE3, 5, 10, 15, 20, 301.5/11.5/12.5/2

3EA33AC -CE

50A2EA52C -CE5, 10, 15, 20, 30, 40, 502.5/22.5/25/3

3EA53C -CE

60A2EA62C -CE602.5/22.5/25/3

3EA63C -CE

FramePoleTypeRated current (A)Rated interrupting 415V ACcapacity (kA) 380V ACIEC 60947-2 (Icu/Ics) 230V AC

100A2EA102C -CE50, 60, 75, 10010/510/525/13

225A2EA202C -CE125, 150, 175, 200, 22518/518/535/18

3EA203C -CE

400A2EA402C -CE250, 300, 350, 40025/1325/1335/18

3EA403C -CE

3EA103C -CE3EA103C -CE

Compact, modular units help to reduce paneldesign and manufacturing costs

EA103C-CE SA203C-CEBW253S0

Page 13: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

11

FramePoleTypeRated current (A)Rated interrupting 415V ACcapacity (kA) 380V ACIEC 60947-2 (Icu/Ics) 230V AC

600A3EA603C -CE500, 60035/1835/1850/25

800A3EA803 -CE700, 80035/1835/1850/25

FramePoleTypeRated current (A)Rated interrupting 415V ACcapacity (kA) 380V ACIEC 60947-2 (Icu/Ics) 230V AC

30A2SA32C -CE3, 5, 10, 15, 20, 302.5/22.5/25/3

3SA33C -CE

50A2SA52C -CE5, 10, 15, 20, 30, 40, 507.5/47.5/410/5

3SA53C -CE

2SA52RC -CE10, 15, 20, 30, 40, 5010/510/525/13

3SA53RC -CE

FramePoleTypeRated current (A)Rated interrupting 415V ACcapacity (kA) 380V ACIEC 60947-2 (Icu/Ics) 230V AC

100A2SA102C -CE15, 20, 30, 40, 50, 60, 75, 10030/830/850/25

3SA103C -CE

2SA102RC -CE15, 20, 30, 40, 50, 60, 75, 10050/1350/13100/50

3SA103RC -CE

FramePoleTypeRated current (A)Rated interrupting 415V ACcapacity (kA) 380V ACIEC 60947-2 (Icu/Ics) 230V AC

2SA202RC -CE125, 150, 175, 200, 22550/1350/13100/50

3SA203RC -CE

225A2SA202C -CE125, 150, 175, 200, 22530/830/850/25

3SA203C -CE

FramePoleTypeRated current (A)Rated interrupting 415V ACcapacity (kA) 380V ACIEC 60947-2 (Icu/Ics) 230V AC

800A3SA803RC -CE700, 80050/2550/2585/43

1000A3SA1003E -CE500-100065/4985/64100/75

1250A3SA1253E -CE500-1000, 630-125065/4985/64100/75

1600A3SA1603E -CE800-160085/64100/75125/94

FramePoleTypeRated current (A)Rated interrupting 415V ACcapacity (kA) 380V ACIEC 60947-2 (Icu/Ics) 230V AC

2SA402RC -CE250, 300, 350, 40050/2550/2585/43

3SA403RC -CE

600A3SA603RC -CE500, 60050/2550/2585/43

400A2SA402C -CE250, 300, 350, 40035/1835/1850/25

3SA403C -CE

FramePoleTypeRated current (A)Rated interrupting 415V ACcapacity (kA) 380V ACIEC 60947-2 (Icu/Ics) 230V AC

60A2SA62C -CE607.5/47.5/410/5

3SA63C -CE

2SA62RC -CE6010/510/525/13

3SA63RC -CE

S series/2, 3-pole

Page 14: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

12

H and L series/2, 3-pole

S and E series/4-pole

FramePoleTypeRated current (A)

Rated interrupting 440V ACcapacity (kA) 400V ACIEC 60947-2 (Icu/Ics) 230V AC

50A2H52BA15, 20, 30, 40, 50

65/1765/17125/32

50A3LA53B5, 10

50/2560/30100/50

100A2H102BA15, 20, 30, 40, 50, 60, 75, 100

65/1765/17125/32

3H103R40, 50, 60, 7510085 (*415V AC)100 (*380V AC)125 (*240V AC)

3H103BA

3H53BA

FramePoleTypeRated current (A)

Rated interrupting 440V ACcapacity (kA) 400V ACIEC 60947-2 (Icu/Ics) 230V AC

400A2H402B250, 300, 350, 400

65/3365/33125/63

3H403R250, 300, 350400125/63125/63125/63

3H403B

600A3H603B500, 600

65/3365/33125/63

3H603R500, 600

125/63125/63125/63

800A3H803B700, 800

65/3365/33125/63

3H803R700, 800

125/63125/63125/63

FramePoleTypeRated current (A)

Rated interrupting 440V ACcapacity (kA) 400V ACIEC 60947-2 (Icu/Ics) 230V AC

225A2H202BA125, 150, 175, 200, 225

65/1765/17125/32

3H203R125, 150, 175200, 22585 (*415V AC)100 (*380V AC)125 (*240V AC)

3H203BA

FramePoleTypeRated current (A)

Rated interrupting 415V ACcapacity (kA) 380V ACIEC 157-1 240V AC

50A4SA54B5, 10, 15, 20, 30, 40507.5 7.5 10

100A4EA104B50, 60, 75, 100

10 15 25

100A4SA104R15, 20, 30, 40, 5060, 75, 10045 50 80

225A4SA204R125, 150, 175, 20022550 50 85

400A4SA404HA250, 300, 350, 400

45 45 85

FramePoleTypeRated current (A)

Rated interrupting 415V ACcapacity (kA) 380V ACIEC 157-1 240V AC

600A4SA604H500, 600

45 4585

800A4SA804H700, 800

45 4585

1000A4SA1004E -CE500-1000

65/49*85/64*100/75 (* 230V AC)

1250A4SA1254E -CE500-1000, 630-1250

65/49*85/64*100/75 (* 230V AC)

1600A4SA1604E -CE800-1600

85/64*100/75*125/94 (* 230V AC)

Note: * Interrupting capacity are conforming to IEC 60947-2 (Icu/Ics)

Note: * Interrupting capacity are conforming to IEC 157-1

See page 06/1 of D & C catalog 19th Edition.Further Information

Page 15: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

13

SeriesFramePoleInstallation

Closing mechanismTripping mechanismOvercurrentprotectiondevice

FixedDraw-out

Characteristic

Protection function

L-characteristicsR-characteristicsS-characteristicsLong time delayShort time delayInstantaneousPre-alarmGround faultEarth leakagePreverse powerN-phase protectionContact temp.monitoring

DH series800, 1250, 1600, 2000, 2500, 3200, 4000A3, 4Available (except 4000AF)AvailableManual spring, motor springShunt trip, undervoltage tripAvailableAvailableAvailableAvailable

AvailableAvailableAvailableAvailableAvailableAvailable

DA series5000, 6000A2, 3, 4Not availableAvailable

AvailableNot availableAvailableAvailable

AvailableAvailableNot availableNot availableAvailableNot available

Selection guide

Comparison of interrupting capacity

Rated current (A)Rated interruptingcapacity (kA sym.)/Rated making current(kA peak)

800A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6000ARated voltage690V AC

Rated voltage440V AC

DHDH HDH PDADHDH HDH PDA

50/105 65/143 75/16555/121

85/18785/187

65/143 85/187 100/22080/176

100/220120/264

StandardsIEC60947-2EN60947-2AS3947-2NEMA PUB No. SG3ANSI C37.13BS EN60947-2VDE 0660 part 101JIS C 8372 (JIS C8201-2)JEC 160

Provides positive protection for electricpower systems

Further Information See page 08/47 of D & C catalog 19th Edition.

DH series

ASTALRABGLBVNK

Page 16: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

14

Illuminated pushbutton switchesOperator

Momentary typeAlternate typeContact arrangementLamp voltage

LampColor of lens

Flush round head

AR22F0LAR22F5L1NO, 1NC, 1NO+1NC, 2NO, 2NC, 2NO+2NC, 3NO, 3NC, 4NO, 4NC, 5NO, 5NC5.5V AC/DC, 6V AC, 6V DC, 12V AC/DC, 15V AC/DC, 20V AC/DC, 24V AC/DC100-110V AC, 115-127V AC, 200-220V AC, 230-254V AC, 350-380V AC, 400-440V AC, 480V AC, 500-550V ACLED lamp, Incandescent lamp Green, Red, White, Yellow, Orange, Blue

Extended round head

AR22E0LAR22E5L

Extended with transparent full guard

AR22G4LAR22G9L

Flush square head

AR22F0MAR22F5M

Extended square head

AR22E0MAR22E5M

Operator

Momentary typeAlternate typeContact arrangementColor of button

Flush round head

AR22F0RAR22F5R1NO, 1NC, 1NO+1NC, 2NO, 2NC, 2NO+2NC, 3NO, 3NC, 3NO+3NC, 4NO, 4NC, 5NO, 5NC Green, Red, Black White, Yellow, Orange, Blue

Extended round head

AR22E0RAR22E5R

Mushroom head

AR22M0RAR22M5R

Flush round head with square bezel

AR22F0YAR22F5Y

Flush square head

AR22F0SAR22F5S

Operator

TypeContact arrangementColor of button

Push-lock, turn-reset(40mm dia.)

AR22V0R1NC, 1NO+1NC, 2NC, 2NO+2NC, 3NC, 4NC Red

Push-lock, turn-reset(29mm dia.)

AR22V4R

Key release push-lock,turn-reset

AR22V7R

Push-lock, pull-reset

AR22Q2R

Unibody push-lock, turn-reset

AR22VGE

Pushbutton switches

Emergency stop pushbutton switches

Ergonomically designed andperfectly suited for control panels

Command SwitchesAR22, DR22 series (22mm dia.)

The manufacturing range varies depending on the model.

AR22, DR22 series

AR30, DR30 series

Page 17: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

15

Lens

TypeLamp voltage

LampColor of lens

Dome

DR22D0L5.5V AC/DC, 6V AC, 6V DC, 12V AC/DC, 15V AC/DC, 20V AC/DC, 24V AC/DC, 110V DC100-110V AC, 115-127V AC, 200-220V AC, 230-254V AC, 350-380V AC, 400-440V AC, 480V AC, 500-550V ACLED lamp, incandescent lamp Green, Red, White, Yellow, Orange, Blue

Extended round

DR22E3L

Flush square(transparent lens)

DR22F4M

Flush square

DR22F3M

Extended square

DR22E3M

Pilot lights

Operator

Type Konb/key operated controlContact arrangementColor of knob

Knob

AR22PRAR22PCR1NO, 1NC, 1NO+1NC, 2NO, 2NC, 2NO+2NC, 3NO, 3NC, 3NO+3NC, 4NO, 4NC, 5NO, 5NC Black, Green, Red

Lever

AR22WRAR22WCR

Key

AR22JRAR22JCR

Key (Long durability)

AR22JAR–

Selector switches

AR30, DR30 series (30mm dia.)

Illuminated pushbutton switchesOperator

Momentary typeAlternate typeContact arrangementLamp voltage

LampColor of lens

Extended round head

AR30E0LAR30E5L1NO, 1NC, 1NO+1NC, 2NO, 2NC, 2NO+2NC, 3NO, 3NC, 4NO, 4NC, 5NO, 5NC5.5V AC/DC, 6V DC, 6V AC, 12V AC/DC, 15V AC/DC, 20V AC/DC, 24V AC/DC100-110V AC, 115-127V AC, 200-220V AC, 230-254V AC, 350-380V AC, 400-440V AC, 480V AC, 500-550V ACLED lamp, incandescent lamp Green, Red, White, Yellow, Orange, Blue

Extended with transparent full guard

AR30G4LAR30G9L

Extended with full guard

AR30G3LAR30G8L

Extended with full guard(with openings)

AR30G2LAR30G7L

Push-lock, turn-reset

–AR30V5L

Operator

Momentary typeAlternate typeContact arrangementColor of button

Flush round head

AR30F0RAR30F5R1NO, 1NC, 1NO+1NC, 2NO, 2NC, 2NO+2NC, 3NO, 3NC, 3NO+3NC, 4NO, 4NC, 4NO+4NC, 5NO, 5NC Green, Red, Black White, Yellow, Orange, Blue

Extended round head

AR30E0RAR30E5R

Mushroom head

AR30M0RAR30M5R

Extended with full guard

AR30G1RAR30G6R

Giant head with full guard

AR30B2R–

Pushbutton switches

The manufacturing range varies depending on the model.

Page 18: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

16

Further Information

See page 04/2 of D & C catalog 19th Edition.

Lens

TypeLamp voltage

LampColor of lens

Dome

DR30D0L5.5V AC/DC, 6V AC, 6V DC, 12V AC/DC, 15V AC/DC, 20V AC/DC, 24V AC/DC, 50V DC, 110V DC, 100-110V AC 115-127V AC, 220V DC, 200-220V AC, 230-254V AC, 350-380V AC, 400-440V AC, 480V AC, 500-550V ACLED lamp, incandescent lamp Green, Red, White, Yellow, Orange, Blue

Extended round

DR30E3L

Faceted

DR30K0L

Flush square

DR30F4M

Pilot lights

Operator

Type Knob/key operated controlContact arrangementColor of knob

Knob

AR30PRAR30PCR1NO, 1NC, 1NO+1NC, 2NO, 2NC, 2NO+2NC, 3NO, 3NC, 3NO+3NC, 4NO, 4NC, 4NO+4NC, 5NO, 5NC Black, Green, Red

Lever

AR30WRAR30WCR

Key

AR30JRAR30JCR

Key (Long durability)

AR30JAR–

Selector switches

Operator

TypeContact arrangementColor of button

Push-lock, turn-reset(40mm dia. with white arrow)

AR30V0R1NC, 1NO+1NC, 2NC, 2NO+2NC, 3NC, 4NC Red

Push-lock, turn-reset(65mm dia. )

AR30V1R

Push-lock, turn-reset(40mm dia. )

AR30V2R

Push-lock, pull-reset

AR30Q2R

Emergency stop pushbutton switches

The manufacturing range varies depending on the model.

Page 19: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

17

Super timersDescription Operation Contact arrangement Timer Required socket

Surface mounting Flush mounting Rail mountingTimed Instant. Type Type Type Type

Super Timer Multi-mode 2PDT – MS4SM TP411X TP411SBA+TX4 TP411XMulti-range, • On-delay 11GB (Adaptor)compact body • Flicker + ATX2NS+TX4

• One-shot FX3 (Adaptor)• Signal off-delay (Hold-down spring)

On-delay 2PDT – MS4SA TP48X TP48SB+TX4 TP48XSPDT SPDT MS4SC 8GB (Adaptor)

Off-delay 2PDT – MS4SF + ATX1NS+TX4SPDT MS4SF-R FX3 (Adaptor)

Star-delta 2NO 1NO MS4SY

On-delay 2PDT – MS4SEwith electrical resetOn-off repetitive 2PDT – MS4SRoperationOn-off SPDT – MS4SB

Description Contact arrangement Input voltage (V) Timer Required socketTimed Instant. Surface mounting Surface mounting Flush mounting

Type Type Type

Digital timer SPDT – 100–110V AC SD4 TP28X-ULSPDT – 200–220V AC SD4D

24V DC

SPDT – 100–240V AC MD4E-AP TP48X24V AC/DC MD4E-CE 8GB

TP48SBATX1NS

TP48SBATX1NS

On-delay 2PDT – ST7P-2 TP88 – TP88X2Off-delay SPDT – ST7PF TP88R2 TP88X1

TP88B

On-delay 4PDT – ST7P-4 TP814 – TP814X2TP814R2 TP814X1TP814B

Super TimerMiniaturesize

(Hold-down spring)

Direct reading time-scaleand compact body

See page 03/49 of D & C catalog 19th Edition.

MS4S

Digital timers

Further Information

Page 20: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

18

Miniature control relays HH52, 53, 54

TypeContact arrangementContact formRated thermal currentResistive load

Inductive loadL/R=15ms (DC)Cosø=0.3 to 0.4 (AC)Contact resistanceCoil Rated voltage

Power consumption

HH522PDTSingle5A5A5A5A0.3A1.5A2A0.2A50mΩ max. 6 to 240V AC, 6 to 110V DC (50/60Hz)AC: 1.0/1.2VA max. (60Hz), 1.2/1.4VA max. (50Hz) DC: 0.9W

HH533PDTSingle5A5A5A5A0.3A1.5A2A0.2A

HH544PDTSingle3A3A3A3A0.3A1A2A0.2A

HH52 U2PDTSingle7A7A7A7A0.3A1.5A2A0.2A

HH54 U4PDTSingle5A5A5A5A0.3A1A2A0.2A

HH52 W2PDTBifurcated5A5A5A5A0.3A1.5A2A0.2A

HH54 W2PDTBifurcated3A3A3A3A0.3A1A 2A0.2A

• SocketsDescriptionSoldering

PC board

Wire wrap

Rail mounting Screw terminal M3.5

Rail mounting Screw terminal M3.0

TypeTP58TP511TP514TP58BTP511BTP514BTP58R2TP511R2TP514R2TP58X2TP511X2TP514X2TP58X1–TP514X1

Used withHH52PHH53PHH54PHH52PHH53PHH54PHH52PHH53PHH54PHH52PHH53PHH54PHH52P–HH54P

120V AC240V AC 30V DC120V DC

120V AC 30V DC120V DC

Solder PC board

Rail mounting

Wire wrap

Reliable operation and long life

HH54

StandardsUL, CSA, TÜV

Page 21: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

19

Miniature power relays HH62, 63, 64

TypeContact arrangementContact formRated thermal currentResistive load

Inductive loadL/R=15ms (DC)Cosø=0.3 to 0.4 (AC)Contact resistanceCoil Rated voltage

Power consumption

HH622PDTSingle10A10A10A8A0.3A1.5A2A0.2A50mΩ max. 6 to 240V AC, 6 to 110V DC (50/60Hz)AC: 2VA max. (60Hz), 2.5VA max. (50Hz) DC: 1.5W max.

HH633PDTSingle10A10A10A8A0.3A1.5A2A0.2A

HH644PDTSingle10A10A10A8A0.3A1.5A2A0.2A

HH62 W2PDTBifurcated7A5A5A5A0.3A1.5A2A0.2A

• SocketsDescription

SolderingPC boardWire wrapRail mounting screw terminal

Finger protection cover

Type

TP68TP68BTP68RTP68X2TP611X2TP614X2RZ62X2RZ64X2

Used with

HH62

HH62HH63HH64TP68X2TP614X2

120V AC240V AC 30V DC120V DC120V AC 30V DC120V DC

Further Information

See page 03/25 of D & C catalog 19th Edition.

StandardsUL, CSA, TÜV

Page 22: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

20

UM02

UM03

Performs precise energy control at low cost

F-MPC04UM01-A A4EIntegrated power monitoring unit

F-MPC04PUM02-AR2Multi-circuit power monitoring unit

UM02-AR3 UM02-AR4F-MPC04UM03-ARA3GSingle-circuit power monitoring unit

UM03-ARA3

Measuring function

Protection

Communications interfaceDisplay and settingDevices to be connected

Type

No. of phases and wires

No. of voltage circuitsMeasuring item

Maintenance item

Harmonic currentCurrent prealarm (OCA)Leakage current prealarm (OCGA)Leakage current trip (OCG)

Current sensor (Current Transformer:CT)

Single-phase 2-wireSingle-phase 3-wire 3-phase 3-wire3-phase 4-wire

VoltageCurrentPowerActive powerReactive powerReactive energyPower-factorLeakage currentBasic component of leakage currentDemand

Max. voltage valueMin. voltage value

[V][A][W][Wh][var][varh]

[Io]

[Iob]CurrentPowerMax. currentMax. power

10 circuits10 circuits

6 circuits2

RS-485, T-link

*

12 circuits—

—1

––

–––

––––RS-485Display and setting unit UM02SCT: 5, 50, 200, 400A

—8 circuits

——

4 circuits

1 circuit

—1

–– (Demand only)

RS-485

1 circuit

—1

––

––

––RS-485

ZCT (separately installed)MCCB with ZCT

––

––

Note: * F-MPC 04 (UM01) is connected to CT via CT-BOX. Available

F-MPC04

UM01

Further Information See page 09/119 of D & C catalog 19th Edition.

Page 23: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

Sales area: China

Fuji Electric (Shanghai) Co., Ltd.Suite A.B.C, 17 FI., East Bldg.Shanghai New Hualian MansionNo. 755 Huai Hai Rd. (Middle)200020 ShanghaiTHE PEOPLE’S REPUBLIC OF CHINATel: +86-21-6466-2810Fax: +86-21-6473-3292URL http://www.fesh.com.cn

Sales area: Hong Kong

Fuji Electric (ASIA) Co., Ltd.Rm. 1001,10 FI., West Wing, TsimshatsuiCenter, 66 Mody Rd., Tsimshatsui East KowloonHONG KONGTel: +852-2311-8282Fax: +852-2312-0566

Sales area: Taiwan

Fuji Electric FA Taiwan Co., Ltd.12 Fl., No. 70, Cheng Teh Rd., Sec. 1Taipei 103, TAIWAN ROCTel: +886-2-2556-0716Fax: +886-2-2556-0717URL http://www.fcs.fujielectric.com.tw

Sales area: Korea

Fuji Electric FA KOREA Co., Ltd.16 Fl, Shinsong Bldg. 25-4Youido-dong, Youngdungpo-guSeoul, 150-010, KOREATel: +82-2-780-5011Fax: +82-2-783-1707

Sales area: South East Asia, Oceania

Fuji Electric FA Singapore Private Ltd.171, Chin Swee Rd.12-01/04 San CentreSingapore 169877, SINGAPORETel: +65-6533-0010Fax: +65-6533-0021URL http://www.fujielectric.com.sg

Sales area: Thailand

Fuji Electric Technology Co., Ltd.889 Thai CC Tower, 12th Fl., Rm. 124South Sathorn Rd., Yannawa, SathornBangkok 10120, THAILANDTel: +66-2-210-0615Fax: +66-2-675-6641

Sales area: North America

Fuji Electric Corp. of AmericaPark 80 West Plaza II, Saddle BrookNJ 07663, U.S.A.Tel: +1-201-712-0555Fax: +1-201-368-8258URL http://www.fujielectric.com

Sales area: Europe

Fuji Electric GmbHGoethering 5863067 Offenbach am MainF.R. GERMANYTel: +49-69-6690290Fax: +49-69-6661020URL http://www.fujielectric.de

Distribution and Control ProductsSales Centers

Page 24: FUJI Low Voltage Distribution and Control Equipment Fuji...Manual motor starters Magnetic contactors and starters Magnetic contactors and starters Magnetic contactors VCB CT T VT solid

Printed in Japan 2005-2 sh100 FISInformation in this catalog is subject to change without notice.

5-7, Nihonbashi Odemma-cho, Chuo-ku, Tokyo, 103-0011, Japan

URL http://www.fujielectric.co.jp/fcs/eng

Safety Considerations• For safe operation, before using the product read the instruction manual or user manual that comes with the product carefully or consult the

Fuji sales representative from which you purchased the product.• Products introduced in this catalog have not been designed or manufactured for such applications in a system or equipment that will affect

human bodies or lives.• Customers, who want to use the products introduced in this catalog for special systems or devices such as for atomic-energy control,

aerospace use, medical use, passenger vehicle, and traffic control, are requested to consult the Fuji sales division.• Customers are requested to prepare safety measures when they apply the products introduced in this catalog to such systems or facilities

that will affect human lives or cause severe damage to property if the products become faulty.• For safe operation, wiring should be conducted only by qualified engineers who have sufficient technical knowledge about electrical work or

wiring.