222
First Edition INSTALLATION / SERVICE MANUAL / PARTS LIST < Optional Software > DIGITAL MINILAB FRONTIER 350/370 355/375/570 Frontier Manager Printer Controller PP3-A1060E (FRONTIER 355/375 System Disk Ver.1.7) (FRONTIER 570 System Disk Ver.1.7) (FRONTIER 350/370 System Disk Ver.7.7) Frontier Manager Printer Controller Ver.2.0 distributed by www.minilablaser.com

Fuji FRONTIER 350 370 SERVICE MANUAL

Embed Size (px)

DESCRIPTION

Fuji FRONTIER 350 370INSTALLATIONSERVICE MANUALPARTS LIST

Citation preview

Page 1: Fuji FRONTIER 350 370 SERVICE MANUAL

First Edition

INSTALLATION / SERVICE MANUAL / PARTS LIST

< Optional Software >

DIGITAL MINILAB

FRONTIER

350/370 355/375/570

Frontier Manager Printer Controller

PP3-A1060E

(FRONTIER 355/375 System Disk Ver.1.7)(FRONTIER 570 System Disk Ver.1.7)

(FRONTIER 350/370 System Disk Ver.7.7)Frontier Manager Printer Controller Ver.2.0

distributed by www.minilablaser.com

Page 2: Fuji FRONTIER 350 370 SERVICE MANUAL

INTRODUCTION

This manual outlines the maintenance and servicing procedures, electrical diagram and parts list for the Frontier Manager Printer Controller (referred to as FMPC) for Fujifilm Digital Minilab FRONTIER 350/370/355/375/570.

This manual is a professional publication provided for qualified service personnel or other persons fully trained in equipment service procedures. All other personnel and operators are restricted from servicing the FMPC. When maintenance service is needed, be sure to contact qualified service personnel.

When servicing internal machine parts, make sure the power switch and the main power supply on the power distribution board are both set to the OFF position.If the main power is left ON, electricity will flow as far as the power switch and power supply section, and this can cause electric shocks and/or short-circuiting.If the power is left on, there is also the possibility for the machine to be accidentally activated causing damage to the machine and/or bodily injury.

The light source section and dryer will be hot to the touch. Wait 15 minutes after turning off the power before commencing with servicing procedures.

IMPORTANTIMPORTANT describes improper handling procedures that may adversely affect performance or damage the equipment.

NOTE:NOTE designates those items, provisions, and supplementary explanations for which it is important to maintain methodical concern and consideration relative to operational procedures.

: describes additional or useful information.

1. All rights are reserved by the Fuji Photo Film Co., Ltd. (FUJIFILM).

2. Manual usage is restricted to FUJIFILM equipment-related technical and service personnel.

3. This manual contains exclusive information relating to FUJIFILM equipment and is therefore proprietary. Unauthorized disclosure is prohibited.

4.FUJIFILM’s prior consent is required in regard to the following.

KManual copying in whole or in part.KDisclosure of manual contents to unauthorized personnel.KManual uses for purposes other than technical service.

Precautions Generally Applying to All Servicing Operations

Service Manual Appropriations

distributed by www.minilablaser.com

Page 3: Fuji FRONTIER 350 370 SERVICE MANUAL

CONTENTSdistributed by www.minilablaser.com

1 Preparations .......................................................................................................................... 10

1.1 Recommended PC, Monitor Switcher, and Extension Cable for Keyboard ....................... 10

1.1.1 Recommended PC................................................................................................. 10

1.1.2 Recommended Monitor Switcher ........................................................................... 10

1.1.3 Extension Cable for Keyboard................................................................................ 10

1.1.4 SP-3000 Monitor's Power Cable ............................................................................ 10

1.1.5 Ethernet Cable ....................................................................................................... 10

1.2 Checking the Kit Contents ................................................................................................. 11

1.3 Required Tools and CDs ................................................................................................... 13

1.4 Power Souce Specification ................................................................................................ 13

2 Installation for FRONTIER 570 ....................................................................................... 14

2.1 Installation Procedure List ................................................................................................. 14

2.2 PC Preparations ................................................................................................................ 15

2.2.1 IEEE1394 Board Installation .................................................................................. 15

2.2.2 Bios Setup .............................................................................................................. 16

2.2.3 Windows XP Installation and Partitioning............................................................... 16

2.2.4 Setup of Remaining Space in Hard Disk ................................................................ 18

2.2.5 Installing Other Driver Software ............................................................................. 21

2.2.6 User Registration.................................................................................................... 21

2.2.7 Windows Settings................................................................................................... 22

2.2.8 NetBEUI Setup ....................................................................................................... 28

2.3 IEEE1394 Driver Pre-installation ....................................................................................... 29

2.4 Copying Print Size Table from SP to FD ........................................................................... 30

2.5 Creating Backup FD for SP-3000 and LP5700 .................................................................. 30

2.6 Changing Mode from SP-3000 to FMPC ........................................................................... 31

2.7 Connecting FMPC, FRONTIER, LAN Cable and Monitor Switcher ................................... 31

2.8 Turning on LP5700 ............................................................................................................ 35

2.9 Turning on FMPC and Installing LP5700 Driver ................................................................ 36

2.10 Installing SP-3000 Driver ................................................................................................... 37

2.11 Disabling Network Connection on SP Side ....................................................................... 38

2.12 Installing FMPC Software [D20] ........................................................................................ 39

2.13 Copying SP-3000 Print Size Table to FMPC ..................................................................... 40

2.14 Installing DI Print/Data Writing Software [C4/C5] Client in FMPC ..................................... 40

2.15 Turning on Imaging Controller ........................................................................................... 41

2.16 Input/Output Device Setup for FMPC ................................................................................ 41

2.17 Timer Setup in FMPC ........................................................................................................ 42

2.18 Installation Information Setup in FMPC ............................................................................. 43

2.19 Paper Condition Setup ...................................................................................................... 43

2.20 FMPC Output Device Setting in Imaging Controller .......................................................... 44

2.21 Operational Check ............................................................................................................. 45

2.22 Creating Backup FD for FMPC/SP-3000 ........................................................................... 50

2.23 System Shutdown .............................................................................................................. 50

3

Page 4: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

3 Installation for FRONTIER 355/375 ............................................................................... 51

3.1 Installation Procedure List ................................................................................................. 51

3.2 PC Preparations ................................................................................................................ 53

3.3 Disabling of “Rack Auto Cleaning” ..................................................................................... 53

3.4 Creating Backup FD for SP-3000 and LP1500/2000 ......................................................... 54

3.5 Replacing the ROM for Printer .......................................................................................... 55

3.6 Connecting FMPC, FRONTIER, LAN Cable and Monitor Switcher ................................... 56

3.7 Turning on FMPC .............................................................................................................. 60

3.8 Disabling Network Connection on SP Side ....................................................................... 60

3.9 IEEE1394 Driver Installation in SP .................................................................................... 60

3.10 [A1] Stand-alone Version-up and DI Print/Data Writing Software Installation in SP .......... 61

3.11 IEEE1394 Driver Pre-installation ....................................................................................... 63

3.12 Installing IEEE1394 Driver for SP in FMPC ....................................................................... 64

3.13 Starting-up LP in ROM Mode and Checking ROM Version (2.0-0x-000) .......................... 65

3.14 Installing IEEE1394 Driver for LP in FMPC ....................................................................... 65

3.15 FMPC [D20] Installation (Reinstall) with Printer’s Backup FD ........................................... 66

3.16 DI Print/Data Writing Software [C4/C5] Client Installation in FMPC .................................. 69

3.17 Installation Information Setup for FMPC ............................................................................ 70

3.18 Output Device Setup for SP and Restarting SP ................................................................ 70

3.19 Copying Print Size Table to FD then Copying SP-3000 Print Size Table to FMPC .......... 71

3.20 FMPC Output Device Setting in Imaging Controller .......................................................... 72

3.21 Enabling of “Rack Auto Cleaning” ..................................................................................... 73

3.22 Paper Condition Setup ...................................................................................................... 73

3.23 Creating Backup FD for FMPC, SP-3000 and LP1500/2000 ............................................ 74

3.24 Operational Check ............................................................................................................. 75

3.25 System Shutdown .............................................................................................................. 75

4 Installation for FRONTIER 350/370 ............................................................................... 76

4.1 Installation Procedure List ................................................................................................. 76

4.2 PC Preparations ................................................................................................................ 78

4.3 Disabling of “Rack Auto Cleaning” ..................................................................................... 78

4.4 Creating Backup FD for SP1500/2000, LP1500/2000 ....................................................... 79

4.5 Replacing the ROM for Printer .......................................................................................... 80

4.6 Connecting FMPC, FRONTIER, LAN Cable and Monitor Switcher ................................... 81

4.7 Turning on FMPC .............................................................................................................. 85

4.8 Disabling Network Connection on SP Side ....................................................................... 86

4.9 [A1] Stand-alone Upgrade in SP [Ver.1.5 -> Ver.1.7] and

DI Print/Data Writing Software [C4/C5] Client Installation in SP ....................................... 87

4.10 IEEE1394 Driver Pre-installation ....................................................................................... 89

4.11 Installing IEEE1394 Driver for SP in FMPC ....................................................................... 90

4.12 Starting-up LP in ROM Mode and Checking ROM Version (2.0-0x-000) .......................... 90

4.13 Installing IEEE1394 Driver for LP in FMPC ....................................................................... 91

4.14 FMPC [D20] Software Installation (Reinstall) with Printer's Backup FD ............................ 92

4.15 DI Print/Data Writing Software [C4/C5] Client Installation in FMPC .................................. 95

4

Page 5: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

4.16 Installation Information Setup for FMPC ............................................................................ 96

4.17 Output Device Setup for SP and Restarting SP ................................................................ 97

4.18 Copying Print Size Table to FD then Copying LP1500/2000 Print Size Table to FMPC ... 98

4.19 FMPC Output Device Setting in Imaging Controller .......................................................... 99

4.20 Enabling of “Rack Auto Cleaning” ..................................................................................... 99

4.21 Paper Condition Setup ...................................................................................................... 99

4.22 Creating Backup FD for FMPC, SP1500/2000 and LP1500/2000 ..................................... 100

4.23 Operational Check ............................................................................................................. 101

4.24 System Shutdown .............................................................................................................. 101

5 Maintenance Menu (FRONTIER 350/370/355/375) .................................................. 102

5.1 Operational Procedure ...................................................................................................... 102

5.2 System Operation Setup and Check (41) .......................................................................... 103

5.2.1 Production Information 1 (411)............................................................................... 103

5.2.2 Production Information 2 (412)............................................................................... 104

5.2.3 Accumulated Production Information (413) ............................................................ 105

5.2.4 Timer Setup (414) ................................................................................................. 106

5.2.5 Error Information Check (415)............................................................................... 107

5.2.6 Installation Information Confirmation (416) ............................................................ 108

5.2.7 Data Backup (417) ................................................................................................. 108

5.2.8 Clear Error Log (41E) ............................................................................................. 109

5.2.9 Installation Information Setup (41F) ....................................................................... 110

5.2.10 DI Manager Administrative Setting (41l)................................................................. 110

5.3 Print Condition Setup and Check (42) ............................................................................... 111

5.3.1 Paper Condition Setup ........................................................................................... 111

5.3.2 Processing Solution Temperature Check............................................................... 113

5.3.3 Control Strip Processing......................................................................................... 113

5.3.4 Print Size Setup (424) ............................................................................................ 116

5.3.5 Paper Condition Method Setup (42J) ..................................................................... 117

5.3.6 Back Print Setup (42O) .......................................................................................... 117

5.4 Printer Adjustment/Maintenance (45) ................................................................................ 118

5.4.1 Paper Magazine Registration (451)........................................................................ 118

5.4.2 Paper Feed Length Adjustment (452) .................................................................... 120

5.4.3 Test Pattern Printing (453) ..................................................................................... 121

5.4.4 G, B Laser (SHG) Optimal Temperature Setup (454) ............................................ 122

5.4.5 Paper Feed (455) ................................................................................................... 123

5.4.6 Printer Temperature Display (456) ......................................................................... 123

5.4.7 Printer Input Check (457) ....................................................................................... 124

5.4.8 Image Position Fine Adjustment (458) ................................................................... 124

5.4.9 Printer I/O Check (45A) .......................................................................................... 125

5.4.10 Printer Function Select (45B) ................................................................................. 126

5.4.11 Laser Exposure Check (45C) ................................................................................. 127

5.4.12 R Laser (R-LD) Data (45D) .................................................................................... 127

5.4.13 G Laser (G-SHG) Data (45E) ................................................................................. 128

5.4.14 B Laser (B-SHG) Data (45F) .................................................................................. 128

5

Page 6: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

5.4.15 Scanning Position/Scanning Home Position Parameter Setup (45G).................... 129

5.4.16 Main Scanning Position Adjustment/Laser Beam Sync. Rough

Adjustment (45H) ................................................................................................... 129

5.4.17 Laser Beam Sync. Fine Adjustment Print (45J) ..................................................... 131

5.4.18 Laser History Display (45K).................................................................................... 132

5.4.19 Paper Condition Setup Table (LUT) Copy (45L) .................................................... 132

5.4.20 Printer Mechanism Fine Adjustment (45M) ............................................................ 133

5.4.21 Back Printer Test (45N).......................................................................................... 134

5.4.22 Printer Operation Data Display (45P)..................................................................... 134

5.4.23 Data Saving (45T) .................................................................................................. 135

5.4.24 Data Download (45U)............................................................................................. 135

5.4.25 Precut Length Setting (45V) ................................................................................... 136

5.5 Processor Adjustment/Maintenance (46) .......................................................................... 137

5.5.1 Replenisher Pump Output Measurement ............................................................... 137

5.5.2 Auto-cleaning Pump Output Measurement ............................................................ 138

5.5.3 Processing Temperature Setting (463) .................................................................. 141

5.5.4 Replenisher Rate Setup (464)................................................................................ 141

5.5.5 Evaporation Correction Rate Setting (465) ............................................................ 142

5.5.6 Low Volume Setting (466) ...................................................................................... 142

5.5.7 Processor Temperature Calibration (467) .............................................................. 143

5.5.8 Processor Input Check (468).................................................................................. 144

5.5.9 Processor I/O Check (46A) .................................................................................... 145

5.5.10 Processor Operating Condition Setup (46B) .......................................................... 146

5.5.11 Processor Operation Data Display (46C) ............................................................... 146

5.5.12 Processor Operation Data Display 2 (46E) ............................................................ 147

5.6 Special Operations (48) ..................................................................................................... 148

5.6.1 Paint (48A) ............................................................................................................. 148

5.6.2 Explorer (48B) ........................................................................................................ 148

5.6.3 Command (48C)..................................................................................................... 149

6 Maintenance Menu (FRONTIER 570) ........................................................................... 150

6.1 Operational Procedure ...................................................................................................... 150

6.2 System Operation Setup and Check (1) ............................................................................ 151

6.2.1 Production Information 1 (411)............................................................................... 151

6.2.2 Production Information 2 (412)............................................................................... 152

6.2.3 Accumulated Production Information (413) ............................................................ 154

6.2.4 Timer Setup (414) .................................................................................................. 155

6.2.5 Error Information Check (415)................................................................................ 156

6.2.6 Installation Information Reference (416) ................................................................ 157

6.2.7 Data Backup (417) ................................................................................................. 157

6.2.8 Clear Error Log (41E) ............................................................................................. 158

6.2.9 Installation Information Setup (41F) ....................................................................... 159

6.2.10 DI Manager Administrative Setting (41I) ................................................................ 159

6.3 Print Condition Setup and Check (2) ................................................................................. 160

6.3.1 Paper Condition Setup (421).................................................................................. 160

6

Page 7: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

6.3.2 Print Size Setup (424) ............................................................................................ 162

6.3.3 Paper Condition Method Setup (42J) ..................................................................... 163

6.3.4 Back Printing Setup (42O)...................................................................................... 164

6.3.5 Paper Surfaces Display Setup (42R) ..................................................................... 165

6.4 Printer Adjustment/Maintenance (5) .................................................................................. 166

6.4.1 Paper Magazine Registration (451)........................................................................ 166

6.4.2 Paper Magazine Feeding Fine Adjustment (452)................................................... 168

6.4.3 Test Pattern Printing (453) ..................................................................................... 169

6.4.4 G Laser (SHG) Optimal Temperature Setup (454)................................................. 171

6.4.5 Paper Feed (455) ................................................................................................... 172

6.4.6 Printer Temperature Display (456) ......................................................................... 172

6.4.7 Printer Input Check (457) ....................................................................................... 173

6.4.8 Image Position and Tilt Fine Adjustment (458) ...................................................... 173

6.4.9 Printer I/O Check (45A) .......................................................................................... 174

6.4.10 Printer Function Select (45B) ................................................................................. 175

6.4.11 Laser Exposure Check (45C) ................................................................................. 176

6.4.12 R Laser (R-LD) Data (45D) .................................................................................... 177

6.4.13 G Laser (G-SHG) Data (45E) ................................................................................. 177

6.4.14 B Laser (B-LD) Data (45F) ..................................................................................... 178

6.4.15 Scan/Scan Home Position Parameter (45G).......................................................... 178

6.4.16 Main Scan/Laser Beam Sync. Rough Adjustment (45H) ....................................... 179

6.4.17 Laser Beam Sync. Fine Adjustment Print (45J) ..................................................... 180

6.4.18 Laser History Display (45K).................................................................................... 181

6.4.19 Paper Condition Setup Table (LUT) Copy (45L) .................................................... 182

6.4.20 Printer Mechanical Fine Adjustment (45M) ............................................................ 182

6.4.21 Printer Operation Data Display (45P)..................................................................... 183

6.4.22 Data Saving (45T) .................................................................................................. 183

6.4.23 Data Download (45U)............................................................................................. 184

6.4.24 Filter Replacement History (45a)............................................................................ 184

6.4.25 Feeding Position Sensor Fine Adjustment (45b).................................................... 185

6.4.26 Image Position Initial Setting (45c)......................................................................... 186

6.4.27 Sub-scan Feeding Speed Adjustment (45d) .......................................................... 187

6.4.28 Sub-scanning Soft Nip Fine Adjustment (45e) ....................................................... 187

6.4.29 Sensor Calibration (Initial) (45f).............................................................................. 188

6.4.30 Sensor Calibration (Daily) (45g) ............................................................................. 189

6.5 Processor Adjustment/Maintenance (6) ............................................................................ 190

6.5.1 Replenisher Pump Output Measurement/Setting (461) ......................................... 190

6.5.2 Auto Cleaning Output Measurement/Setting (462) ................................................ 192

6.5.3 Processing Temperature Setting (463) .................................................................. 194

6.5.4 Low Volume Processing Setup (466) ..................................................................... 195

6.5.5 Processor Temperature Calibration (467) .............................................................. 195

6.5.6 Processor Input Check (468).................................................................................. 197

6.5.7 Processor I/O Check (46A) .................................................................................... 197

6.5.8 Processor Operating Condition Setup (46B) .......................................................... 198

6.5.9 Processor Operation Data Display (46C) ............................................................... 199

7

Page 8: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

6.5.10 PS Liquid Concentration Management (46G) ........................................................ 199

6.6 Option Adjustment / Maintenance (7) ................................................................................ 200

6.6.1 COM Port Setting (47A) ......................................................................................... 200

6.7 Special Operations (9) ....................................................................................................... 201

6.7.1 Paint (49A) ............................................................................................................. 201

6.7.2 Explorer (49B) ........................................................................................................ 201

6.7.3 Command (49C)..................................................................................................... 202

7 Error Messages and Countermeasures ..................................................................... 203

7.1 Error Indication Rule .......................................................................................................... 203

7.1.1 Message Number ................................................................................................... 203

7.1.2 Message Icons ....................................................................................................... 203

7.1.3 X-#### Actions ....................................................................................................... 203

7.2 Messages .......................................................................................................................... 204

8 Measures against FMPC Failures ................................................................................. 212

8.1 To Return to Direct-connecting Type in FRONTIER 350/370 ........................................... 212

8.2 To Return to Direct-connecting Type in FRONTIER 355/375 ........................................... 215

9 Index ......................................................................................................................................... 218

8

Page 9: Fuji FRONTIER 350 370 SERVICE MANUAL

9

■ How to Read This Manual

(1) Chapter Contents This manual consists of the following chapters.

Chapter1 PreparationsDescribes the devices, tools and power source required for installation.

Chapter2 Installation for FRONTIER 570Describes the installing procedures for the FMPC for FRONTIER 570.

Chapter3 Installation for FRONTIER 355/375Describes the installing procedures for the FMPC for FRONTIER 355/375.

Chapter4 Installation for FRONTIER 350/370Describes the installing procedures for the FMPC for FRONTIER 350/370.

Chapter5 Maintenance Menu (FRONTIER 350/370/355/375)Describes the maintenance menu (“Setup and Maintenance”) for the FMPC for FRONTIER 350/370/355/375.

Chapter6 Maintenance Menu (FRONTIER570)Describes the maintenance menu (“Setup and Maintenance”) for the FMPC for FRONTIER 570.

Chapter7 Error Messages and CountermeasuresLists up the FMPC error messages and their countermeasures.

Chapter8 Measures against FMPC failuresDescribes how to connect SP to LP directly when the FMPC malfunctions.

Chapter9 Index

(2) Abbreviation for DevicesThe abbreviation of devices at the upper right-hand of the page (in the Chapter Title bar) shows where the current installing operation is done. The following abbreviations are used.

• Frontier Manager Printer Controller: FMPC • Imaging Controller: IC • FRONTIER Scanner: SP • FRONTIER Printer: LP • FRONTIER 350/370: F350/370 • FRONTIER 355/375: F355/375 • FRONTIER 570: F570 • FRONTIER 350/370/355/375/570: F350/370/355/375/570

(3) Notation for Screen/Button Name • Screen name is enclosed within “ ”. • Button name is enclosed within [ ] parentheses. • Items on the screen is enclosed within [ ] parentheses.

Abbriviation

distributed by www.minilablaser.com

Page 10: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

1 Preparations

1.1.1 Recommended PC

• Model : Dell Optiplex GX280 (No monitor)

• Main Body : Small Mini Tower

• CPU : Pentium-4 2.8GHz/800FSB (FSB800MHz)

• Chip Set : IntelR 915G Express

IntelR Hyper-Threading Function disabled

• Memory : 1GB/DDR2 SDRAM 400MHz

• HDD : Serial ATA 80GB/7200rpm

• Network : IntelR Pro/1000MT(10/100/1000) for interface

• I/O Devices : 3.5˝ FDD, CD-ROM, Built-in Audio-speaker

• OS : WindowsR XP Professional SP1/SP2

• PCI Bus : More than 3 (for IEEE1394 x 2 and 2nd Serial Adapter Card)

• Dimension : (Width x Height x Depth) : 181 x 447 x 426 mm

IMPORTANT:• To supply the power source to the FMP, make sure to use the power source cable, sharing the grounding with the

printer as much as possible, so that the voltage deviation between the FMPC and printer does not occur.• Install the FMPC so shat their cables are not tightened. For example, if the 1394 board is loosened by pulling the cable,

the communication error may occur.

1.1.2 Recommended Monitor Switcher

• CPU Auto-Switcher

• PC: IBM PC/AT

• Keyboard : PS/2 Keyboard

• Mouse : PS/2 Mouse

• Monitor : HD(3WAY)/Multi-scan display with 15pin connector

• OS : WindowsR XP, WindowsR 2000, WindowsR NT

• Method : Electric Control by pressing the select switches or pressing [Ctrl] key twice quickly (hot-key

switching)/ Auto-scanning

1.1.3 Extension Cable for Keyboard

• Extension cable for keyboard : KB-KYE2 (2m)

• Supported keyboard : General keyboard (Mini-DIN 6pin-type)

1.1.4 SP-3000 Monitor's Power Cable

1.1.5 Ethernet Cable

1.1 Recommended PC, Monitor Switcher, and Extension Cable for Keyboard

10

Page 11: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

Check the kit contents.

[FMPC Kit]

1.2 Checking the Kit Contents

Part Name Part No. Shape and Identification

1 FMP Controller Kit 899C21583A2

2 FMPC Software 899C21583A4

IEEE1394 Board x 2 ROM (for CTL CB)

FMP Controller [D20] CD Ver.2.0-0E-101

IEEE1394 Cable (4.5m) x 1

Instruction Manual

Installation/Service Manual/

Parts List

F350/370 System Software [A1]

Ver.7.7-0E-201

F355/375/570 System Software [A1] CD Ver.1.7-0E-105

F355/375/570 Driver Disk

Custom ButtonSetting Tools CD

Blank FD forBackup (3)

FMP Controller Driver Disk

Operator Quick Reference Guide

FMP Controller [D20] CD Ver.2.0-0E-101

F350/370 System Software [A1]

Ver.7.7-0E-201

F355/375/570 System Software [A1] CD Ver.1.7-0E-105

F355/375/570 Driver Disk

Custom ButtonSetting Tools CD

FMP Controller Driver Disk

11

Page 12: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

[Each Part]

Part Name Part No. Shape and Identification

1 IEEE 1394 Board 113C898440

2 ROM(for CTL CB) 114C898435

3 IEEE 1394 Cable (4.5m)

136C898441

4 FMP Controller [D20] CD Ver.2.0-0E-101

114C6006886E00

5 F355/375/570 System Software [A1] CD Ver.1.7-0E-105

114C2159701E03

6 FRONTIER 350/370 System Software [A1] CD Ver.7.7-E

114C6006883E01

7 F350/370 System Software [A1] CD Ver.7.7-0E-201

8 Installation/Service Manual/Parts List

12

Page 13: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

• ROM remover or screw driver (-)

• Windows XP Professional SP1/SP2 CD

• DI Print/Data Writing Service Software [C4/C5] CD

• Insulating tape

• Print Size Set Tool Software (FD)

• “3KPrintsizeCopyTool” Software (FD)

(used only in case of FRONTIER 355/375)

Make sure that the AC power at the installation location is correct by checking the rated label of the PC.

Part Name Part No. Shape and Identification

9 Operator Quick Reference Guide

10 Custom Button Setting Tools CD

114C2159702E00

11 1394 Driver Disk for SP-3000

114C2159703X00

12 1394 Driver Disk for FMPC

114C6006884X00

13 Blank FD for Backup CD

114C1062675(FMPC)114C1062676(SP)114C1058873(LP)

1.3 Required Tools and CDs

1.4 Power Souce Specification

13

Page 14: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

2 Installation for FRONTIER 570 FMPC

Install the FMPC devices and software, and set them up for use.

Install the FMPC using the following procedure.

FMPC = Frontier Manager Printer Controller

SP = Scanner

LP = Printer

IC = Imaging Controller

2.1 Installation Procedure List

No. Procedures Location Refer to

1 IEEE1394 Board Installation FMPC See Section 2.2.1 on page 15

2 PC Preparations FMPC See Section 2.2 on page 15

3 IEEE1394 Driver Pre-installation FMPC See Section 2.3 on page 29

4 Copying Print Size Table from SP to FD SP See Section 2.4 on page 30

5 Creating Backup FD for SP-3000 and LP5700 SP See Section 2.5 on page 30

6 Changing Mode from SP-3000 to FMPC SP See Section 2.6 on page 31

7 Connecting FMPC, FRONTIER, LAN cable and Monitor Switcher

SP, FMPC, LP, Monitor Switcher See Section 2.7 on page 31

8 Turning on LP5700 LP See Section 2.8 on page 35

9 Turning on FMPC and Installing LP5700 Driver

FMPC See Section 2.9 on page 36

10 Installing SP-3000 Driver FMPC See Section 2.10 on page 37

11 Disabling Network Connection on SP Side FMPC See Section 2.11 on page 38

12 Installing FMPC Software [D20] FMPC See Section 2.12 on page 39

13 Copying SP-3000 Print Size Table to FMPC FMPC See Section 2.13 on page 40

14 Installing DI Print/Data Writing Software [C4/C5] Client in FMPC

FMPC See Section 2.14 on page 40

15 Turning on Imaging Controller IC See Section 2.15 on page 41

16 Input/Output Device Setup for FMPC FMPC See Section 2.16 on page 41

17 Timer Setup in FMPC FMPC See Section 2.17 on page 42

18 Installation Information Setup in FMPC FMPC See Section 2.18 on page 43

19 Paper Condition Setup FMPC/LP See Section 2.19 on page 43

20 FMPC Output Device Setting in Imaging Controller

IC See Section 2.20 on page 44

21 Operational Check FMPC,SP, LP, IC, Monitor Switcher

See Section 2.21 on page 45

22 Creating Backup FD for FMPC/SP-3000 FMPC, SP See Section 2.22 on page 50

23 System Shutdown SP, FMPC, IC See Section 2.23 on page 50

14

Page 15: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

2.2.1 IEEE1394 Board Installation

Install the two 1394 boards in the FMPC.

1 While pressing the two buttons on each side, open the upper cover slowly.

2 Lift up the board stopper while pressing the hook.

3 Remove the second and third dummy covers from the left in the board section.

4 Insert the 1394 board into the slot that is the third from the left, then pressing it on slowly, and then confirm that it is securely installed in the slot.

5 In the same way, install another 1394 board in the slot that is the second from the left.

2.2 PC Preparations

Upper Cover

Buttons (2)NMP001

Board Stopper

HookNMP002

Dummy Covers (2)

NMP003

1394 Board

NMP004

1394 Board

NMP005

15

Page 16: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

6 Lower the stopper until the click sounds to secure the boards.

7 Close the upper cover.

2.2.2 Bios Setup

Start up the FMPC, then press the [F2] key just

when “Strike F1 to retry boot, F2 for setup utility”.

Make sure that “Hyper - threading” is set to

“Disabled”.

If [Hyper-Threading] is changed to “Enabled”, the Windows must be installed again.

2.2.3 Windows XP Installation and Partitioning

Install the Windows XP Professional in the FMPC

PC, then set up the partition.

It is not necessary to install it when using a PC with Windows XP Professional already installed.

[Procedures]

1 Insert the Windows XP Professional installer CD into the CD drive.

Board Stopper

NMP006

Upper Cover

NMP007

NMP012

16

Page 17: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

2 Set up the PC again.

3 When the message “Press any key to boot from CD” appears, press the [Enter] key.

4 When the message “Windows XP Licensing Agreement” appears, press the [F8] key if you agree to the terms of the license.

5 When the message “The following list shows the existing partitions and unpartitioned space on this computer” appears, press the [D] key to delete all existing partition(s).

6 When the message “The partition you tried to delete is a system partition” appears, press the [Enter] key, then the [L] key.

7 After all partitions are deleted, select [Unpartitioned space], then press the [C] key.

8 Set “10000MB” for the partition size, and press the [Enter] key.

9 Select the above “10000MB” partition, and press the [Enter] key.

10 Format this partition with NTFS.

NMP010

Press any key to boot from CD.

Windows XP Licensing Agreement

Microsoft Windows XP Professional.Microsoft (r) Windows (r) XP Tablet PC Edition andMicrosoft (r) Windows (r) XP Media Center EditonEND-USER LICENSE AGREEMENT

IMPORTANT-READ CAREFULLY : This End-UserLicense Agreement (“EULA”) is a legal agreement between you (either an individual or a single legal entity) and the manufacturer (“Manufacturer”) of the computer system or computer system component (“HARDWARE”) with which you acquired the Microsoft software product (s) identified on the Certificate of Authenticity (“COA”) affixed to the HARDWARE or on the associated product documentation (“SOFTWARE”). The SOFTWARE includes Microsoft computer software, and may include associated media, printed materials, “online” or electronic documentation, and Internet based services. Note, however, that any software, documentation, or web services that are included in the SOFTWARE, or accessible via the SOFTWARE, and are accompanied by their own license agreements or terms of use are governed by such agreements rather than this EULA.The terms of printed paper EULA, which may accompany the

Windows XP Professional Setup

The following list shows the existing partitions andunpartitioned space on this computer.

Use the UP and DOWN ARROW key to select an item in the list.

• To set up Windows XP on the selected item, press ENTER.

• To create a partition in the unpartitioned space, press C.

• To delete the selected partition, press D.

76294 MB Disk 0 at Id 0 on bus 0 on atapi [MBR]

C: Partition 1 [New (Raw)] 10001 MB ( 10001 MB free)Unpartitioned space 66292 MB

Windows XP Professional Setup

The following list shows the existing partitions and unpartitioned space on this computer.

Use the UP and DOWN ARROW keys to select an item in the list.

• To set up Windows XP on the selected item, press ENTER.

• To create a partition in the unpartitioned space, press C.

• To delete the selected partition, press D.

76294 MB Disk 0 at Id 0 on bus 0 on atapi [MBR]

Unpartitioned space 76293 MB

Windows XP Professional Setup

You asked Setup to create a new partition on76294 MB Disk 0 at Id 0 on bus 0 on atapi [MBR].

• To create the new partition, enter a size below and press ENTER.

• To go back to the previous screen without creating the partition, press ESC.

The minimum size for the new partition is 8 megabytes (MB).The maximum size for the new partition is 76285 megabytes (MB).Create partition of size (in MB): 100000

Windows XP Professional Setup

The following list shows the existing partitions and unpartitioned space on this computer.

Use the UP and DOWN ARROW keys to select an item in the list.

• To set up Windows XP on the selected item, press ENTER.

• To create a partition in the unpartitioned space, press C.

• To delete the selected partition, press D.

76294 MB Disk 0 at Id 0 on bus 0 on atapi [MBR]

C: Partition1 [New (Raw)] 1001 MB (10001 MB free) Unpartitioned space 66292 MB

Windows XP Professional Setup

The partition you selected is not formatted. Setup will now format the partition.

Use the UP and DOWN ARROW key to select the file system you want, and then press ENTER.

If you want to select a different partition for Windows XP, press ESC.

Format the partition using the NIFS file system (quick)Format the partition using the FAT file system (quick)Format the partition using the NIFS file systemFormat the partition using the FAT file system

17

Page 18: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

11 After the format is completed, the PC is automatically restarted.

12 After the restart, DO NOT press any key until the wizard screen appears even if “Press any key to boot from CD” is displayed.

13 While following the Wizard instructions, complete [Regional and Language Options], [Personalize Your Software], [Computer Name and Administrator Password] and [Date and Settings].

14 After the system is restarted, Windows XP Desktop screen appears.

15 Restart the PC, and change the drive reading order at the start-up to [1. Diskette Drive] -[2. Hard-disk Drive C:] - [3. IDE CD-ROM Device] (For procedures, See “2.2.2 Bios Setup” on page 16.).

2.2.4 Setup of Remaining Space in Hard Disk

Set up the remaining space in the hard disk.

1 On the Desktop, select [Start] - [Control Panel] - [Administrative Tool] - [Computer Management] to display the “Computer Management” screen.

2 Right-click on the unallocated area, then select [New Partition].

3 On the “Welcome to New...” screen, click the [Next] button.

Windows XP Professional Setup

This portion of Setup has completed successfully.

If there is a floppy disk in drive A:, remove it.

To restart your computer, press ENTER.When your computer restarts. Setup will continue.

Your computer will reboot in 2 secons....

18

Page 19: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

4 On the “New Partition Wizard” screen, select [Extended partition], then click the [Next] button.

5 Click the [Next] button.

6 Click the [Finish] button.

7 In the same area on the “Computer Management” screen, right-click, then select [New Logical Drive].

8 On the “Welcome to New...” screen, click the [Next] button.

9 On the “Select Partition Type” screen, select [Logical drive], then click the [Next] button.

19

Page 20: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

10 Click the [Next] button.

11 Specify “D” for [Assign the following...], then click the [Next] button.

12 Select [NTFS] for “File system”, then click the [Next] button.

13 Formatting is started.

14 After formatting is completed, check if “New Volume” is “Healthy”.

15 Right-click on the CD drive, then select [Change Drive Letter and Paths].

20

Page 21: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

16 Select “N”, and then click the [OK] button.

17 Click the [X] button to close the opened screens.

2.2.5 Installing Other Driver Software

Install other driver software provided in the DELL

setup CD. (For details, see “Instruction Manual” for

DELL PC.)

2.2.6 User Registration

Register the following user name and password.

The following procedures are an example when

using the Wizard.

1 On the Desktop, select [Start] - [Control Panel] - [User Accounts], then on the “User Accounts” screen, click [Create a new account], then [Apply Options] button, then enter “FRONTIER” and then click the [Next] button.

2 Select “Computer administrator”, then click the [Create Account] button.

USER NAME: FRONTIER

PASSWORD: FRONTIER

GROUP: Administrator

21

Page 22: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

3 On the “User Accounts” screen, click [Change the way users log on or off], then enter “FRONTIER” both in the “Type a new password” and “Type a new password again...”, then click the [Create Password] button.

4 Open the “Control Panel” screen, then click [Switch to Classic View].

5 Click the [User Account] button, then click [Change the way users log on or off], and then on the “Select logon and logoff options” screen, remove the checkmark [✓] from “Use the Welcome screen”, then click the [Apply options] button.

2.2.7 Windows Settings

Set up the Windows functions.

Log on with the user name “FRONTIER”, then start settings.

(1) Disabling of Windows XP Style

1 After the system is restarted, right-click on any part of the Desktop, then open the [Display Properties] screen, and then select [Windows Classic] for [Theme].

2 On the Desktop, select [Start] - [Run], then on the “Run” screen, enter “Services.msc”, then click the [OK] button.

3 On the “Service” screen, double-click [Themes].

22

Page 23: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

4 On the “Themes Properties (Local Computer)” screen, select “Disabled” for [Startup type], then click the [Stop], then [OK] button.

(2) Password History Setting

1 On the Desktop, select [Start] - [Control Panel] - [Administrative Tools] - [Local Security Policy] to open the “Local Security Settings” screen.

2 Select [Password Policy] - [Enforce password history], then in the “Enforce password history Properties” dialog, select “0” for [Password remembered], then click the [Apply], then [OK] button.

(3) Long Date Format Setting

1 Double-click the [Regional and Language Options] on the “Control Panel” screen, then on the “Regional Options” tab screen, click the [Customize] button to set a long date format, then click the [Apply] - [OK] buttons.

(4) System Error Setting

1 On the Desktop, select [Start] - [Control Panel] - [System], then on the “System Properties” screen, click [Advanced] tab, then click the [Settings] button for [Startup and Recovery], then set up as shown below.

23

Page 24: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

2 After the above items are set, click the [OK] button.

(5) Disabling of User Assistant Function

1 On the Desktop, select [Start] - [Control Panel] - [Accessibility Options], then in the “Settings for StickyKeys” dialog, click the [Settings] for [StickyKeys], then remove all checkmarks [✓], then click the [OK] button.

2 In the “Settings for StickyKeys” dialog, click the [Settings] for [FilterKeys], then remove all check marks [✓], then click the [OK] button.

3 In the “Settings for StickyKeys” dialog, click the [Settings] for [ToggleKeys], then remove the checkmark [✓] in the “Use shortcut”, then click the [OK] button.

[✔] : Write an event to the system log[✔] : Send an administrative alert[ ] : Automatically restart“Complete memory dump” for [Write debugging information]“D:\MEMORY.DMP” for [Dump file][✔] : Overwrite any existing file

24

Page 25: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

4 Click the [OK] button to close the “Settings for StickyKeys” dialog.

(6) Non-display Setting of Screen Keyboard Dialog Box

1 On the Desktop, select [Start] - [All Programs] - [Accessories] - [Accessibility] - [On-screen Keyboard].

2 Add the checkmark [✓] to “On-Screen Keyboard” dialog, then click the [OK] button.

(7) Disabling of Error Reporting

1 On the Desktop, select [Start] - [Control Panel] - [System], then on the “System Properties” screen, click [Advanced] tab, then click the [Error Reporting] button.

25

Page 26: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

2 Select “Disable error reporting”, then remove the checkmark [✓] from “But notify me....”, then click the [OK] button.

(8) Non-display Setting for Taskbar

3 On the Desktop, select [Start] - [Control Panel] - [Taskbar and Start Menu], add the checkmark [✓] to “Auto-hide the taskbar”, then click the [OK] button.

(9) Screen Resolution

1 Right-click on any part of the Desktop, then on the “Settings” tab screen of the “Display Properties” screen, select more than “800 by 600 pixels” for “Screen area”, then more than 24 bit (True Color) for “Colors”, then click the [Apply] - [OK] buttons.

(10) Non-display Setting of Screen Saver

1 Right-click on any part of the Desktop, then on the “Screen Saver” tab screen of the “Display Properties” screen, set “None” for “Screen saver”, then click the [Apply] - [OK] buttons.

26

Page 27: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

(11) Disabling of Power Standby

1 Double-click the [Power Options] on the “Control Panel” screen, then on the “Power Options Properties” tab screen, select “Never” for “Turn off monitor”, “Turn off hard disks” and “System standby”, then click the [Apply] - [OK] buttons.

(12) Disabling of Auto Update

1 On the Desktop, select “Control Panel” - “System” - “Automatic Updates”, then remove the checkmark [✓] from “Keep my computer up to date. ........”, then click the [Apply] - [OK] buttons.

(13) Disabling of Desktop Cleanup

1 Right-click on any part of the Desktop, then select “Desktop” tab - “Customize desktop”, then remove the checkmark [✓] from "Desktop cleanup", then click the [OK] button.

(14) “Visual Notification” to ON in Dr. Watson Dialog Box

1 On the Desktop, select [Start] - [Run], then enter “Drwtsn32” and then click the [OK] button. In the “Dr. Watson for Windows” dialog box, add the checkmark [✓] to “Visual Notification” in “Options”.

27

Page 28: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

(15) Non-display Setting of Internet Explorer Dialog Box

1 Select [Control Panel] - [Internet Options] - [Security] tab, then click the [Custom Level...], then select [Miscellaneous] - [Submit nonencrypted form data], then select “Enable”.

When using the Service Pack2 (SP2), also set up

the following two items.

(16) Disabling the Windows Fire Wall

1 Open the [Control Panel].

2 Double-click the [Windows Fire Wall].

3 Select [Off], then click the [OK] button.

(17) Disabling the Security Center

1 On the Desktop screen, select [Start] -> [Run], then enter “service.msc”, and then click the [OK] button.

2 Double-click the [Security Center] to open the properties screen, then select [Disabled] for [Startup type], and then click the [Stop] button.

3 Click the [Apply], then [OK] button.

2.2.8 NetBEUI Setup

Set up the NetBEUI protocol in the FMPC.

[Required Files]To set up the NetBEUI, the following files stored in

the Windows XP installer CD are required.

CD Drive\Valueadd\Msft\Net\Netbeui

They are to be copied in the following folders in the

HD of the FMPC.

NOTE:Make all files and their extensions visible by using [Tools]/[FolderOptions] before hand.

[Procedures]

1 Right-click on the [My Network] icon to open the “My Network Properties” screen.

2 Copy “Netnbf.inf” and “nbf.sys” in the CD to any folder in the hard disk.

3 Open the “Local Area Connection Properties”.

4 Click the [Install] button.

File Name Target Folder

1 Netnbf.inf C:\windows\inf

2 nbf.sys C:\windows\system32\drivers

28

Page 29: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

5 Select [Protocol], then click the [Add] button. 6 Select [NetBEUI Protocol], then click the [OK] button.

7 Make sure that the [NetBEUI Protocol] is added in the list.

8 This completes the NetBEUI seup.

1 Insert the FMPC driver CD into the CD-ROM, then in the “Device Drivers Disk [D-01]” dialog box, click the [OK] button. This completes the FMPC driver disk setup.

2 When the FMPC driver disk setup is completed normally, the “Device Drivers Disk [D-02]” dialog box appears. Remove the driver disk from the CD-ROM drive, then click the [OK] button to shut down the system. After shutdown, turn on the FMPC.

2.3 IEEE1394 Driver Pre-installation

29

Page 30: Fuji FRONTIER 350 370 SERVICE MANUAL

SP

distributed by www.minilablaser.com

Copy the print size table from SP to FD by using the

dedicated print size copy tool.

1 Insert the print size copy tool FD into the FD drive of SP-3000, open the Explorer, then execute “PrintSizeTool.exe” in FD.

2 When the FRONTIER model and System [A1] is proper, the following message appears. Click the [OK] button to start copying it to the system.

3 After copying, the following message appears.

Create a backup FD for SP-3000 and LP5700 in

SP.

[Selection]“4 Setup and Maintenance” - ”1 System Operation

and Check” - ”7 Data Backup”

1 Prepare a new floppy disk for data backup when backing up data.

NOTE:A floppy disk is unnecessary for pricing unit data backup because data is backed up to the hard disk of the main control unit.

2 Insert the floppy disk into the floppy drive of the main control unit.

3 Move the cursor to the “Destination” box and select “Film Scanner”, “Printer Processor” or “Pricing Unit”.

NOTE:Perform the data backup for the pricing unit when pricing unit data is changed. Data is backed up from the pricing unit to the hard disk of the main control unit. If the data backup is not performed, changed pricing unit data is canceled when starting up the system next time.

4 Click the [OK] button.

• The “Making the backup of the data” message

appears.

5 Upon completion of the backup, click the [Cancel] button.

• Operation returns to the menu screen.

6 Remove the floppy disk from the drive.

2.4 Copying Print Size Table from SP to FD

2.5 Creating Backup FD for SP-3000 and LP5700

30

Page 31: Fuji FRONTIER 350 370 SERVICE MANUAL

SP LPFMPCSP /

distributed by www.minilablaser.com

In SP, change the mode from SP-3000 to FMP

Controller, then shut down the SP through the post-

operational checks.

[Selection]

“4 Setup and Maintenance” - ”1 System Operation

Setup and Check” - ”F Installation Information

Setup”

1 Change the output device from “LP-5700” to “FMP Controller”.

2 Click the [OK] button.

• Operation returns to the menu screen.

3 Perform the post-operational checks to shut down the system and then restart the system.

• The new settings are activated.

Connect the SP-3000, FMPC, LP5700, LAN cable

and the monitor switcher.

(1) IEEE1394 Cable Preparation

Bind the bared part of the existing IEEE1394 cable

connected between the printer (LP) and scanner

(SP).

1 Disconnect the IEEE1394 cable from the scanner(SP).

2 Remove the clamp from the cable.

3 Bind the bared part of the cable with insulating tape.

2.6 Changing Mode from SP-3000 to FMPC

2.7 Connecting FMPC, FRONTIER, LAN Cable and Monitor Switcher

MP047

Clamp

Insulating Tape

IEEE1394 Cable

MP006

31

Page 32: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPCSP LP

distributed by www.minilablaser.com

(2) IEEE1394 Cable Connection Preparations

Connect the IEEE1394 cable from the LP to the connector in right-hand board, then connect the cable from

the SP to the one in the left-hand board.

IMPORTANTDo not connect the two cables to the same board in the FMPC.

IMPORTANTMake sure that the IEEE1394 cable from scanner (SP) is connected to the lower board, and the cable from printer (LP) to the upper board.

Printer (LP)

Existing IEEE1394 Cable (10m)

IEEE1394 Cable (4.5m)

Scanner (SP)

32

Page 33: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPCSP LP

distributed by www.minilablaser.com

(3) Monitor Switcher Connections

Connect the FMPC, monitor switcher, and FRONTIER as follows.

It is recommended that the monitor switcher be installed on the main control unit.

By placing the full keyboard as shown above, you can press the [Ctrl] key easily to switch the display.

MP046

33

Page 34: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPCSP LP

distributed by www.minilablaser.com

(4) Other Connections

Connect the FMPC, FRONTIER and the monitor switcher and then connect the LAN cable from the HUB to

which the Imaging Controller is connected as shown in the following connection diagram.

To Imaging Controller

5

3

1

4

2

1

3

4

HUB

FRONTIER (SP)

Monitor Switcher

(Front)

(Back)

Main Control Unit (SP)FMPC

Power Supply

Keyboard

Mouse

IMPORTANTConnect the monitor’s power cable to the power supply directly. Do not connect the scanner’s power connector.

34

Page 35: Fuji FRONTIER 350 370 SERVICE MANUAL

LP

distributed by www.minilablaser.com

Turn on the LP5700.

2.8 Turning on LP5700

L2987

35

Page 36: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

Set the driver CD in the CD drive, then turn on the

FMPC. Then log on with following user name and

password.

After the start-up, the “Found New Hardware

Wizard” screen appears. Follow the screen

instructions to complete the driver installation.

1 On the “Found New Hardware Wizard” screen, click the [Next] button.

2 On the “Completing the Found...” screen, click the [Finish] button. This completes the installation of the driver for LP5700 normally.

2.9 Turning on FMPC and Installing LP5700 Driver

NMP010

User Name: FRONTIERPassword: FRONTIER

36

Page 37: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

In FMPC, run and complete “VDEntry” to install the

SP-3000 driver.

1 On the Desktop, select [Start] - [Run], then enter “VDEntry” and then click the [OK] button.

2 In the “VirtualDriverEntry” dialog box, click the [Regist.] button.

3 After the registration, the following dialog box appears. Click the [OK] button to complete the VDEntry.

4 On the “Welcome to the Found...” screen, click the [Next] button.

5 When the “Completing the Found New...” screen appears, click the [Finish] button. This completes the SP-3000 driver installation.

2.10 Installing SP-3000 Driver

37

Page 38: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

Disable the 1394 network connection on SP side.

1 Disconnect the IEEE1394 cable (for connecting to LP5700) from the FMPC.

2 Select [Start] - [Control Panel], then click the [Network Connections].

IMPORTANTCheck the settings are done as follows: 1394 Connection on SP: Disabled1394 Connection on LP: Enabled

3 Right-click on the 1394 Connection whose status is “Enabled”, then set it to “Disabled”.

4 Connect the IEEE1394 cable (for connecting to the LP5700) to the FMPC again.

5 Shut down the FMPC from [Start] - [Shut Down...]

2.11 Disabling Network Connection on SP Side

38

Page 39: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

1 Start up the FMPC, the log on to the FMPC PC with the user “FRONTIER” and with the password “FRONTIER”, then insert the installer CD into the CD drive. The installer is automatically started up. If the installer is not stared up, select the executable file “N:\Setup.exe” in the CD drive directly.

2 Procedure Selection [A-001]On the “Procedure Selection [A-001]” screen, select “New Installation”, then click the [Next] button to start installation.

3 Starting New Installation [A-010]

[Yes]: Starts the new installation.[No]: Returns to the “Procedure Selection [A-

001]” screen.

4 Copying of files in CD to HDD is started up.

5 In the “New Installation Completion [A-020]” dialog box, click the [OK] button.

6 In the “Setup Completion [A-030]” dialog box, remove the FMPC installer CD from the CD drive, then click the [OK] button to complete the installation.

IMPORTANTThe “Setup Completion (A-030)” dialog box prompts you to install the DI Print/Data Writing Service [C4/C5] successively, but here click the [OK] button to close the installation, because the print size table must be copied first.

2.12 Installing FMPC Software [D20]

39

Page 40: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

Copy the SP-3000 print size table that was copied

to the FD in “2.4 Copying Print Size Table from SP

to FD”, to the FMPC.

1 Insert the print size copy tool FD in which the sizes are stored in “2.4”, and then open the “Explorer”, then double-click “PrintSizeSetTool.exe” in FD drive.When the connections are properly done, the following message appears. To start copying, click the [OK] button.

2 Another confirmation message appears. Click the [OK] button to start copying.

3 Data is copied from the FD to FMPC.

4 When copying is completed, the following message appears.

5 Remove the FD from the FD drive.

1 Insert the DI Print/Data Writing Software [C4/C5] installer CD into the CD drive of the FMPC, then start the installation.

2 Remove the [C4/C5] installer CD from the CD drive, then restart the FMPC PC.

2.13 Copying SP-3000 Print Size Table to FMPC

2.14 Installing DI Print/Data Writing Software [C4/C5] Client in FMPC

40

Page 41: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPCIC

distributed by www.minilablaser.com

Turn on the Imaging Controller.

On the “[41F] Installation Information Setup” screen in “Setup and Maintenance”, set “SP-3000 (V1.7-)” to

[Input Device], then “LP5700” to [Output Device], then shut down the FMPC PC through the “Post-operational

Check”, then start it up again.

2.15 Turning on Imaging Controller

2.16 Input/Output Device Setup for FMPC

C4C509

41

Page 42: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

Perform the “[414] Timer Setup” in “Setup and

Maintenance” in the FMPC.

NOTE:The timer ON date/time of the scanner cannot be set.

1 To update “Present time setup”, change the date and time, and click [OK] button.

NOTE:To cancel the update, press the [Cancel] button.

2 To change the timer On date and time, check the day of the week and enter the time in the “Timer ON Date/Time Setting” box.

3 Set the preheat timer by follow the steps below, if necessary.

IMPORTANTThe ON time for a night-time preheating operation mist not overlap with the ON time of the weekly timer since night-time preheating takes priority and shuts down all power when it is set OFF.If, for instance, the calendar time is set to 5:00 AM and night-time preheating is turned ON at 3:30 AM, all the power will be shut down two hours later at 5:30 AM.

NOTE:Night-time preheating is usually conducted when the room temperature drops below 10°C (50°F) at night and the temperature is not controlled for 8 or more hours.

1) Select “YES” for “Preheat setting”.

• The 1st and 2nd preheat setting boxes

appear.

2) Move the cursor to “1st Preheat” and enter the

time.

3) Move the cursor to “2nd Preheat” and enter

the time.

NOTE:For preheating only once, set the same time for both the first and second times.

• Select “NO” when no preheat timer is used.

• The second preheating timer is ignored if

the first and second time overlap.

<Example>1st. preheat time: 2:00 AM2nd. Preheat time: 3:00 AMWith the above settings, nighttime preheating will occur from 2:00 AM to 4:00 AM (2 hours).

4 Click the [OK] button.

• Operation returns to the menu screen.

2.17 Timer Setup in FMPC

42

Page 43: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC SP

distributed by www.minilablaser.com

Perform “[41F] Installation Information Setup” in

“Setup and Maintenance” in the FMPC.

1 Enter the same Delivery Date and Startup Date as the dates set in “[0140] Installation Information Setup” in the SP-3000.

2 Click the [OK] button.

3 On the confirmation dialog box, click the [OK} button.

4 After the setup, shut down the FMPC PC through the “Post-operational Check”, then start it up again.

NOTE:Make sure to restart the FMPC.

Perform “[421] Paper Condition Setup” in “Setup and Maintenance” in the FMPC.

IMPORTANTMake sure to perform the paper condition setup for all paper to be used.

2.18 Installation Information Setup in FMPC

2.19 Paper Condition Setup

43

Page 44: Fuji FRONTIER 350 370 SERVICE MANUAL

IC

distributed by www.minilablaser.com

Register the FMPC output device in the Imaging Controller.

■ Setup Example is DI Print/Data Writing [C4/C5]

[Selection]“Print Service - Administration” - ”Output Device” Set up “sRGBFMPC” and “PDFMPC” for [Device].

IMPORTANTInstalling of DI Import/Export Driver Software [C2} must be required.

The default device names for “FMPC” are “sRGBFMPC” and “PDFMPC”.

2.20 FMPC Output Device Setting in Imaging Controller

44

Page 45: Fuji FRONTIER 350 370 SERVICE MANUAL

IC FMPC

distributed by www.minilablaser.com

Perform the film printing in the FRONTIER, then the

DSC printing from Imaging Controller to check the

operation.

(1) Printing from Imaging Controller

[Imaging Controller Operation]

1 Set the media in the drive.

2 In the [OUTPUT] field, select the FRONTIER device.

3 In the [INPUT] field, click the icon of the media you inserted.

4 On the DSC Print Service screen, select the folder in which the images are stored.

5 Select the images to be printed.

6 Click the [Set] button. The image files are listed

2.21 Operational Check

FD121

Click the [Set] button.

Click the icon of the media you inserted.

Select the folder.

Select the images.

45

Page 46: Fuji FRONTIER 350 370 SERVICE MANUAL

IC FMPC

distributed by www.minilablaser.com

up in the [Order Specification Column].

7 The ”Confirmation” dialog appears.

8 Remove the media from the drive.

9 Click the [OK] button.

10 Registering of order is completed.

[FMPC Operation]

11 On the Main Menu screen, select [2 Print], then click the [OK] button.

12 In the [Next Print] list on the “Print Status Notice” screen, the DI order with the status “Printing” is displayed, and then it is printed.

13 After the printing is completed, the order is

Click the [Set] button.

FD124

Click.

46

Page 47: Fuji FRONTIER 350 370 SERVICE MANUAL

SP FMPC

distributed by www.minilablaser.com

moved to the [Done] list.

[Sheets being processed] on the lower right-hand side of the screen shows where the current order is being processed.

14 After the printing is completed, click the [Next Order Stop] button.

15 Click the [Main Menu] button.

16 Control returns to the “Main Menu” screen.

(2) Printing from FRONTIER

If the [Resume] button appears at the bottom of the screen, click it to switch to the [Next Order Stop] button. Then printing is started.

• The images of the first 6 frames appear on the

screen.

47

Page 48: Fuji FRONTIER 350 370 SERVICE MANUAL

SP

distributed by www.minilablaser.com

To skip the frames (not to be printed), select the frames, then press the [PASS] key.

1 Press the [START/ENTER] key if the film feed mode is “Semi”.

• One-way scanning mode:

The film is ejected from the right-hand side of

the film carrier.

• Two-way scanning mode:

The film is ejected from the left-hand side of

the film carrier.

2 Proceed with scanning of the images.

IMPORTANTDo not touch the film while it is being fed through the carriage. Pulling out the film at this time will cause abnormal printing results.

• When the last frame is scanned, the “Order

Data Display” dialog box appears

automatically.

If the [Scan Cancel] key is pressed during pre-scanning, the order is not fixed automatically. To fix such orders, press the [Sort/Order] button.

• The message shown below appears.

• The green indicator lamp blinks when the fine-

scanning is completed.

Z2569

Z2065 Indicator LampZII062

48

Page 49: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

IMPORTANTThe orders that are registered in the FMPC cannot be deleted with the [Print Stop] key. To delete them, select orders one by one, then click the [Cancel] button on the printing status screen.

[FMPC Operation]

3 Press the button of the switcher to display the FMPC main menu screen.

Also by pressing the [Ctrl] key twice quickly, the display can be switched between FRONTIER and FMPC.

4 On the Main Menu screen, select [2 Print], then click the [OK] button.

5 In the [Next Print] list on the “Print Status Notice” screen, the film order with the status “Printing” is displayed, and then it is printed.

6 After the printing is completed, the order is moved to the [Done] list.

[Sheets being processed] on the lower right-hand side of the screen shows where the current order is being processed.

MP019

49

Page 50: Fuji FRONTIER 350 370 SERVICE MANUAL

IC SP FMPC

distributed by www.minilablaser.com

7 After the printing is completed, click the [Next Order Stop] button.

8 Click the [Main Menu] button.

9 Control returns to the “Main Menu” screen.

Create a backup FD for FMPC/SP-3000. (See “2.3.3 Creating Backup FD for SP-3000 and LP5700”)

Shut down the SP-3000, FMPC, then Imaging Controller in this order.

This completes the FMPC installation and setup.

2.22 Creating Backup FD for FMPC/SP-3000

2.23 System Shutdown

50

Page 51: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

3 Installation for FRONTIER 355/375 FMPC

Install the FMPC devices and software, and set them up for use.

Install the FMPC using the following procedure.

[New Installation]

FMPC = Frontier Manager Printer ControllerSP = ScannerLP = PrinterIC = Imaging Controller

3.1 Installation Procedure List

No. Procedures Location Refer to1 IEEE1394 Board Installation FMPC See Section 2.2.1 on page 152 PC Preparations FMPC See Section 3.2 on page 533 Disabling of “Rack Auto Cleaning” SP See Section 3.3 on page 534 Creating Backup FD for SP-3000 and

LP1500/2000SP See Section 3.4 on page 54

5 Replacing the ROM for Printer LP See Section 3.5 on page 556 Connecting FMPC, FRONTIER, LAN Cable

and Monitor SwitcherSP,LP,FMPC, Monitor Switcher See Section 3.6 on page 56

7 Turning on FMPC (PW: FRONTIER) FMPC See Section 3.7 on page 608 Disabling Network Connection on SP Side FMPC See Section 3.8 on page 609 IEEE1394 Driver Installation in SP(Ver.1.5

only)When the scanner (SP) has the System [A1] Ver.1.7, installing or updating of driver in SP is not required.

SP See Section 3.9 on page 60

10 [A1] Stand-alone Version-Up [Ver.1.5 -> Ver.1.7] and DI Print/Data Writing Software [C4/C5] Client Installation in SP

SP See Section 3.10 on page 61

11 IEEE1394 Driver Pre-installation FMPC See Section 3.11 on page 6312 Installing IEEE1394 Driver for SP in FMPC FMPC See Section 3.12 on page 6413 Starting-up LP in ROM Mode and Checking

ROM Version (2.0-0X-000)LP See Section 3.13 on page 65

14 Installing IEEE1394 Driver for LP in FMPC FMPC See Section 3.14 on page 6515 FMPC [D20] Installation (Reinstall) with

Printer’s Backup FDFMPC See Section 3.15 on page 66

16 DI Print/Data Writing Software [C4/C5] Client Installation in FMPC

FMPC See Section 3.16 on page 69

17 Installation Information Setup for FMPC FMPC See Section 3.17 on page 7018 Output Device Setup for SP and Restarting

SPSP See Section 3.18 on page 70

19 Copying Print Size Table to FD then Copping SP-3000 Print Size Table to FMPC(In use of 3KPrintsizeCopyTool)

SP/FMPC See Section 3.19 on page 71

20 FMPC Output Device Setting in Imaging Controller

IC See Section 3.20 on page 72

21 Enabling of “Rack Auto Cleaning” SP See Section 3.21 on page 7322 Paper Condition Setup FMPC See Section 3.22 on page 7323 Creating Backup FD for FMPC, SP-3000 and

LP1500/2000FMPC/SP/LP See Section 3.23 on page 74

24 Operational Check FMPC/SP/LP/IC See Section 3.24 on page 7525 System Shutdown SP/FMPC/IC See Section 3.25 on page 75

51

Page 52: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

[Updating]

FMPC = Frontier Manager Printer ControllerSP = ScannerLP = PrinterIC = Imaging Controller

No. Procedures Location Refer to

1 PC PreparationsPerform “(14) “Visual Notification” to ON in Dr. Watson Dialog Box” and (15) Non-display setting of Internet Explorer Dialog Box” in “2.2.7 Windows Settings”.

FMPC See Section 3.2 on page 53

2 Disabling of “Rack Auto Cleaning” SP See Section 3.3 on page 53

3 Creating Backup FD for SP-3000, LP1500/2000 and FMPC

SP/LP See Section 3.4 on page 54

4 Turning on FMPC (PW: FRONTIER) FMPC See Section 3.7 on page 60

5 IEEE1394 Driver Pre-installation in SP(Ver.1.5 only)

When the scanner (SP) has the System [A1] Ver.1.7, installing or updating of driver in SP is not required.

SP See Section 3.9 on page 60

6 [A1] Stand-alone Version-Up [Ver.1.5 -> Ver.1.7] and DI Print/Data Writing Software [C4/C5] Client Installation in SP

SP See Section 3.10 on page 61

7 Inserting the IEEE1394 Driver Disk then Restarting FMPC

FMPC See Section 3.11 on page 63

8 IEEE1394 Driver for SP Installation in FMPC FMPC See Section 3.12 on page 64

9 Starting-up LP in ROM Mode and Checking ROM Version (2.0-0X-000)

LP See Section 3.13 on page 65

10 IEEE1394 Driver for LP Installation in FMPC FMPC See Section 3.14 on page 65

11 FMPC [D20] Installation (User Version-up) FMPC See Section 3.15 on page 66

12 Enabling of “Rack Auto Cleaning” SP See Section 3.21 on page 73

13 Paper Condition Setup FMPC See Section 3.22 on page 73

14 Creating Backup FD for FMPC, SP-3000 and LP1500/2000

FMPC/SP/LP See Section 3.23 on page 74

15 Operational Check FMPC/SP/LP/IC See Section 3.24 on page 75

16 System Shutdown SP/FMPC/IC See Section 3.25 on page 75

52

Page 53: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC SP

distributed by www.minilablaser.com

(See “2.2 PC Preparations”)

For the installing procedures for 1394 board, See “2.2.1 IEEE1394 Board Installation”.

To minimize the waiting time for installation, select “No” for “Rack Auto Cleaning” in “[46B] Processor

Operating Condition Setup”.

NOTE:After the settings are completed, set to “Yes” again.

3.2 PC Preparations

3.3 Disabling of “Rack Auto Cleaning”

Select “No”.

53

Page 54: Fuji FRONTIER 350 370 SERVICE MANUAL

SP FMPC

distributed by www.minilablaser.com

The data backup FD should be kept in a fixed place

near the machine because it is used after

recovering from trouble or when installing FMPC.

1 Select [Setup and Maintenance] - [01 System Operation Setup and Check] - [0122 Data Backup]

2 Prepare a floppy disk for data backup when backing up film scanner or printer processor data.

3 Move the cursor to the "Destination" box and select “Film Scanner” or “Printer processor”.

4 Click the [OK] button.

• “Making the backup of the data” message

appears.

5 Insert the floppy disk into the drive of the main control unit.

6 Click the [OK] button.

7 Upon completion of the backup, click the [Cancel] button.

• Operation returns to the menu screen.

8 Remove the floppy disk from the disk drive.

IMPORTANTIf FRONTIER has the system [A1] Ver.1.5 or Ver.1.6, insert the 1394 Driver Disk for SP-3000 (See “1.2 Checking the Kit Contents”), then perform the post-operational check.

9 Perform the post-operational checks.

10 In case of updating, use the same procedures as the above to perform creating backup FD for FMPC.

3.4 Creating Backup FD for SP-3000 and LP1500/2000

54

Page 55: Fuji FRONTIER 350 370 SERVICE MANUAL

LP

distributed by www.minilablaser.com

[ROM Replacement]Replace the ROM on the CTL 20 circuit board with

adaptable ROM for FMPC.

1 Turn the power switch to STANDBY, and turn OFF the built-in circuit breaker and the main supply.

2 Remove the 14 screws and then take off the printer control section cover.

3 Remove the five screws and open the control CB bracket.

4 Replace the ROM U16 (40 pins) on the CTL 20 circuit board with the adaptable ROM for FMPC.

3.5 Replacing the ROM for Printer

Printer Control Section Cover

Screws (14)

EZ783

Control CircuitBoard Bracket Screws (5) EZ177

FMPC Adaptable ROM4D005+*

55

Page 56: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPCLPSP

distributed by www.minilablaser.com

(1) IEEE1394 Cable Preparation

Bind the bared part of the existing IEEE1394 cable

connected between the printer (LP) and scanner

(SP).

1 Disconnect the IEEE1394 cable from the scanner (SP).

2 Remove the clamp from the cable.

3 Bind the bared part of the cable with insulating tape.

3.6 Connecting FMPC, FRONTIER, LAN Cable and Monitor Switcher

MP047

Clamp

Insulating Tape

IEEE1394 Cable

MP006

56

Page 57: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPCLPSP

distributed by www.minilablaser.com

(2) IEEE 1394 Cable Connection Preparations

The connection from LP (printer) and SP (scanner) is as shown below. But in this step, do not connect them

to the FMPC.

IMPORTANTDo not connect the two cables to the same board in the FMPC..

IMPORTANTMake sure that the IEEE1394 cable from scanner (SP) is connected to the lower board, and the cable from printer (LP) to the upper board.

Printer (LP)

Existing IEEE1394 Cable (10m)

IEEE1394 Cable (4.5m)

Scanner (SP)

57

Page 58: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPCLPSP

distributed by www.minilablaser.com

(3) Monitor Switcher Connections

Connect the FMPC, monitor switcher, and FRONTIER as follows.

It is recommended that the monitor switcher be installed on the main control unit.

By placing the full keyboard as shown above, you can press the [Ctrl] key easily to switch the display.

MP046

58

Page 59: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPCLPSP

distributed by www.minilablaser.com

(4) Other Connections

Connect the FMPC, FRONTIER and the monitor switcher and then connect the LAN cable from the HUB to

which the Imaging Controller is connected. as shown in the following connection diagram.

To Imaging Controller

5

3

1

4

2

1

3

4

HUB

FRONTIER (SP)

Monitor Switcher

(Front)

(Back)

Main Control Unit (SP)FMPC

Power Supply

Keyboard

Mouse

IMPORTANTConnect the monitor’s power cable to the power supply directly. Do not connect the scanner’s power connector.

59

Page 60: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

Turn on the FMPC, with the password “FRONTIER”.

NOTE:If the scanner's system disk version is 1.7, the above procedure is not necessary.

Select [Start] - [Control Panel] - [Network

Connections], then disable the 1394 network

connection on SP side.

1 Select [Start] - [Control Panel], then click the [Network Connections].

IMPORTANTCheck the setting as follows: 1394 Connection on SP: Disabled1394 Connection on LP: Enabled

2 Right-click on the 1394 Connection whose status is “Enabled”, then set it to “Disabled”.

Perform the pre-installation of the IEEE1394 driver

in the scanner (SP). if the version of system disk

[A1] in scanner is Ver.1.7, this procedures are not

necessary.

1 Connect the FMPC to scanner (SP) with the 1394 cable.

2 Restart the SP.

3 After the SP is restarted, perform the pre-installation following the screen instructions.

4 Replace the CD with the FRONTIER 355/375 System Software [A1] CD, then restart the SP.

3.7 Turning on FMPC

3.8 Disabling Network Connection on SP Side

3.9 IEEE1394 Driver Installation in SP

60

Page 61: Fuji FRONTIER 350 370 SERVICE MANUAL

SP

distributed by www.minilablaser.com

5 Perform the driver installation following the Wizard. (See “3.10 A1 Stand-alone Version-up in SP”)

The following drivers are installed.• EZ2 1394 Device (for Scanner)• 1394 Client Device (for Printer)

If the scanner’s system disk version is 1.7, the

following procedures are not necessary.

1 When the following "(L-001) Simple Upgrade" screen appears after the SP(A1) is started up, click the [OK] button.

2 Select "SE maintenance", then click the [Next >] button.

3 Select "Update stand-alone scanner", then click the [Next >] button.

4 Click the [Yes] button.

5 Click the [Next >] button.

3.10 [A1] Stand-alone Version-up and DI Print/Data Writing Software Installation in SP

61

Page 62: Fuji FRONTIER 350 370 SERVICE MANUAL

SP

distributed by www.minilablaser.com

6 Select "Inherit data from HD", then click the [Next >] button.

7 Click the [OK] button.

8 Click the [OK] button.

After upgrading of A1 is completed, the SP(A1) is

restarted.

NOTE:The connection error message may appear after

restarting, but this causes no problems.

9 Insert the DI Print/Data Writing Software [C4/C5] installer CD into the CD drive of the FMPC, then start the installation.

62

Page 63: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

1 Insert the FMPC driver CD into the CD-ROM, then in the “Device Drivers Disk [D-01]” dialog box, click the [OK] button. This completes the FMPC driver disk setup.

If the driver disk is not started up automatically, run “N:\EZ171\Setup.exe.” (“N:\” varies depending on your system.)

2 When the FMPC driver disk setup is completed normally, the “Device Drivers Disk [D-02]” dialog box appears. Remove the driver disk from the CD-ROM drive, then click the [OK] button to shut down the system. After shutdown, turn on the FMPC.

NOTE:If the FMPC Ver.1.0 is already installed, start up the FMPC while pressing the [Shift] key.(Start pressing the [Shift] key just when the Windows XP logo appears.)

3.11 IEEE1394 Driver Pre-installation

63

Page 64: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

In FMPC, run and complete “VDEntry” to install the

SP-3000 driver.

1 On the Desktop, select [Start] - [Run], then enter “VDEntry” and then click the [OK] button.

2 In the “VirtualDriverEntry” dialog box, click the [Regist.] button.

3 After the registration, the following dialog box appears. Click the [OK] button to complete the VDEntry.

4 On the “Welcome to the Found...” screen, click the [Next] button.

5 When the “Completing the Found New...” screen appears, click the [Finish] button. This completes the SP-3000 driver installation.

3.12 Installing IEEE1394 Driver for SP in FMPC

64

Page 65: Fuji FRONTIER 350 370 SERVICE MANUAL

LP FMPC

distributed by www.minilablaser.com

1 Start up the Printer (LP) in the ROM mode. While counting-down is in progress, press [MENU] - [<-] - [->] - [Enter] in this order, then check that the ROM version is displayed on the panel, and then check if the ROM Version is “(2.0-0x-000)”.

1 Connect the IEEE1394 cable from the printer (LP) to the connector of the upper board in FMPC.

2 On the “Found New Hardware Wizard” screen, click the [Next] button.

3 Remove the all checkmarks, then click the [Next] button.

4 New driver is installed.

5 On the “Completing the Found...” screen, click the [Finish] button. This completes the installation of the driver for LP5700 normally.

6 Check if the device name “1394 Client Device (for printer)” is displayed on the “Device Manager” screen.

7 This completes the FMPC driver installation.

3.13 Starting-up LP in ROM Mode and Checking ROM Version (2.0-0x-000)

3.14 Installing IEEE1394 Driver for LP in FMPC

[ ROM Version ]2.0-0X-000 >

65

Page 66: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

NOTE:Make sure that the ROM version is displayed on the

operation panel in the printer (LP).

1 Insert the FMPC installer CD into the CD drive, then restart the FMPC.

2 The FMPC installer program is automatically started up.If the installer program is not started up, perform the following procedures.(1) Move to [EZ171] folder in the CD drive.

(2) Double-click [setup.exe].

3 Select [Re-Installation], then click the [Next >] button.

In case of updating from Ver.1.0 to Ver.2.0, select "User Version up".

4 Click the [Yes] button.

5 Click the [OK] button.

3.15 FMPC [D20] Installation (Reinstall) with Printer’s Backup FD

NMP012

66

Page 67: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

6 On the “Printers Selection (A-113)” screen, select [LP1500/LP2000], then click the [Next] button.

7 Installation is started.

8 Click the [Yes] button.

9 Click the [No] button.

NOTE:In this case, select [No] because the FMPC backup FD is not prepared yet.

10 Click the [Yes] button.

11 “Information” dialog box appears.

12 Insert the LP backup FD into the FD drive.

13 Click the [OK] button.

14 On the “Input Source Selection [A-135]” screen, select [SP3000 (V1.7-)], then click the [Next] button.

NMP014

67

Page 68: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

15 Click the [OK] button.

16 Click the [OK] button.

17 Remove the FD from the FD drive.

18 Remove the CD from the CD drive.

IMPORTANTDo not start up the LP. If is is started, the LP parameters are initialized.

19 Proceed to “3.16 DI Print/Data Writing Software Installation in FMPC”.

NMP015

NMP013

68

Page 69: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

1 Insert the DI Print/Data Writing [C4/C5] installer CD into the CD drive, then restart the FMPC.

2 The C4/C5 installer program is automatically started up.If the installer is not started up, double-click [setup.exe].

3 Enter the Imaging Controller name, then click the [Next >] button.

4 Click the [Next >] button.

5 After the installation is completed, the “InstallShield Wizard Complete” screen appears.

6 Remove the installer CD from the CD drive.

7 On the “InstallShield Wizard Complete” screen, select “Yes, I will restart ...”, then click the [Finish] button.

3.16 DI Print/Data Writing Software [C4/C5] Client Installation in FMPC

69

Page 70: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC SP

distributed by www.minilablaser.com

1 Select “1) System Condition Setup and Check” - “2) Installation Information Setup”,then set up the “Delivery Date” and “Setup Date”, and then click the [OK] button.

You can check the delivery and startup dates for printer in the "41F Installation Information Setup" on the SP.

1 Restart the SP(Scanner), then open "Setup and Maintenance" - "System Condition Setup and Check" - "Installation Information Setup", and select "FMP Controller" as Output Device, then click the [OK] button.

2 Restart the SP.

IMPORTANTTo activate the settings, the SP must be restarted.

3.17 Installation Information Setup for FMPC

3.18 Output Device Setup for SP and Restarting SP

70

Page 71: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPCSP

distributed by www.minilablaser.com

Copy the print size table from the SP to the FD by

using the dedicated print size copy tool. Then,

copying it to the FMPC

(1) Running of “3KPrintsizeCopyTool”

1 Insert the print size setting tool FD into the FD drive of SP, then select [Setup and Maintenance] -> [Special Operation] -> [Explorer], and then double-click “3KPrintsizeCopyTool.exe” in the [F355_375] folder in the FD drive.

2 On the copy starting screen, click the [Yes] button.

3 After the copy is done, click the [Yes] button in the confirmation dialog box.

4 In the completion dialog box, click the [OK] button.

NOTE:“3KPrintSizeCopyTool” changes the size settings for LP1500/2000 to those for LP5700. Although SP-3000 ver.1.7 has both the tables for LP1500/2000 and LP5700, the FMPC system use the latter only. So the settings for LP1500/2000 must be changed to those for LP5700 using this tool.

(2) Copy Table to FD

1 Insert the print size setting tool FD into the FD drive of SP, then select [Setup and Maintenance] -> [Special Operation] -> [Explorer], and then execute "PrintSizeTool.exe" in the FD.

2 When the FRONTIER model and System [A1] is proper, the following message appears. Click the [OK] button to start copying it to the system.

3 After copying, remove the FD from the FD drive, then click the [OK] button.

3.19 Copying Print Size Table to FD then Copying SP-3000 Print Size Table to FMPC

71

Page 72: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC IC

distributed by www.minilablaser.com

(3) Copy Table from FD to FMPC

1 Copy the print size table to FMPC.On the FMPC, open [Setup and Maintenance] -> [Special Operation] -> [Explorer], then double-click “PrintSizeSetTool.exe” in FD drive.When the connections are properly done, the following message appears. To start copying, click the [OK] button.

2 Another confirmation message appears. Click the [OK] button to start copying.

3 Data is copied from the FD to the FMPC.

4 When copying is completed, the following message appears.

Register the FMPC output device in the Imaging

Controller. (For details of setting, see each

manual.)

■ Setup Example is DI Print/Data Writ-ing [C4/C5]

[Selection][Print Service - Administration] - [Output Device]

Set up “sRGBFMPC” and “PDFMPC” for [Device].

The default device names for “FMPC” are

“sRGBFMPC” and “PDFMPC”.

CAUTIONInstalling of DI Import/Export driver software must be installed.

The output device name is automatically transferred

to the Imaging Controller when opening the "Print

Status Notice" screen in FMPC.

3.20 FMPC Output Device Setting in Imaging Controller

72

Page 73: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

Since the installation process is completed, return “Rack Auto Cleaning” to “Yes” in “[46B] Processor

Operating Condition Setup”.

Set up the paper condition in the FMPC.

NOTE:After the installation is completed, perform the condition setup for all magazines.

3.21 Enabling of “Rack Auto Cleaning”

3.22 Paper Condition Setup

73

Page 74: Fuji FRONTIER 350 370 SERVICE MANUAL

SP

distributed by www.minilablaser.com

Back up the data both in the FMPC and

FRONTIER.

The following procedures are those used for the

FMPC. Also, perform the same procedures for the

FRONTIER.

[Selection]“4 Setup and Maintenance” - “1 System Operation

Setup and Check” - “7 Data Backup”

[Procedure]Make a backup of unit data stored in the hard disk

of the main control unit after changing the “Setup

and Maintenance” data in case unit data is

damaged.

1 Prepare the data backup floppy disk “FMP Controller” or “LP1500/LP2000”

2 Insert the disk into the floppy drive of the main control unit.

3 Move the cursor to the “Destination” box and select “MP Controller” or “Printer”

4 Click [OK]

• “Making the backup of the data” message

appears.

5 Upon completion of the backup, press the [Cancel] button.

• Operation returns to the “4 Setup and

Maintenance” screen.

6 Remove the FD from the drive.

3.23 Creating Backup FD for FMPC, SP-3000 and LP1500/2000

NMP014

NMP015

74

Page 75: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPCSPIC

distributed by www.minilablaser.com

Perform the operational check.

(See “2.21 Operational Check”.)

Shut down the SP-3000, FMPC, then Imaging Controller in this order.

This completes the FMPC installation and setup.

3.24 Operational Check

3.25 System Shutdown

75

Page 76: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

4 Installation for FRONTIER 350/370 FMPC

Install the FMPC devices and software, and set them up for use.

Install the FMPC using the following procedure.

[New Installation]

FMPC = Frontier Manager Printer Controller

SP = Scanner

LP = Printer

IC = Imaging Controller

4.1 Installation Procedure List

No. Procedures Location Refer to

1 IEEE1394 Board Installation FMPC See Section 2.2.1 on page 15

2 PC Preparations FMPC See Section 4.2 on page 78

3 Disabling of “Rack Auto Cleaning” SP See Section 4.3 on page 78

4 Creating Backup FD for SP-3000, LP1500/2000

SP/LP See Section 4.4 on page 79

5 Replacing the ROM for Printer LP See Section 4.5 on page 80

6 Connecting FMPC, FRONTIER, LAN Cable and Monitor Switcher

SP,LP,FMPC, Monitor Switcher See Section 4.6 on page 81

7 Turning on FMPC (PW: FRONTIER) FMPC See Section 4.7 on page 85

8 Disabling Network Connection on SP Side FMPC See Section 4.8 on page 86

9 [A1] Stand-alone Version-Up in SP and DI Print/Data Writing Software [C4/C5] Client Installation in SP

SP See Section 4.9 on page 87

10 IEEE1394 Driver Preinstallation FMPC See Section 4.10 on page 89

11 Installing IEEE1394 Driver for SP in FMPC FMPC See Section 4.11 on page 90

12 Starting-up LP in ROM Mode and Checking ROM Version (2.0-0X-000)

LP See Section 4.12 on page 90

13 Installing IEEE1394 Driver for LP in FMPC FMPC See Section 4.13 on page 91

14 FMPC [D20] Installation (Reinstall) with Printer’s Backup FD

FMPC See Section 4.14 on page 92

15 DI Print/Data Writing Software [C4/C5] Client Installation in FMPC

FMPC See Section 4.15 on page 95

16 Installation Information Setup for FMPC FMPC See Section 4.16 on page 96

17 Output Device Setup for SP and Restarting SP

SP See Section 4.17 on page 97

18 Copying Print Size Table to FD then Copping LP1500/2000 Print Size Table to FMPC

SP/FMPC See Section 4.18 on page 98

19 FMPC Output Device Setting in Imaging Controller

IC See Section 4.19 on page 99

20 Enabling of “Rack Auto Cleaning” SP See Section 4.20 on page 99

21 Paper Condition Setup FMPC See Section 4.21 on page 99

22 Creating Backup FD for FMPC, SP1500/2000 and LP1500/2000

FMPC/SP See Section 4.22 on page 100

23 Operational Check FMPC/SP/LP/IC See Section 4.23 on page 101

24 System Shutdown SP/FMPC/IC See Section 4.24 on page 101

76

Page 77: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

[Updating]

FMPC = Frontier Manager Printer Controller

SP = Scanner

LP = Printer

IC = Imaging Controller

No. Procedures Location Refer to

1 PC PreparationsPerform “(14) “Visual Notification” to ON in Dr.Watson Dialog Box” and “(15) Non-display setting of Internet Explorer Dialog Box” in “2.2.7 Windows Settings”.

FMPC See Section 4.2 on page 78

2 Disabling of “Rack Auto Cleaning” SP See Section 4.3 on page 78

3 Creating Backup FD for SP1500/2000, LP1500/2000 and FMPC

SP/LP See Section 4.4 on page 79

4 Turning on FMPC(PW: FRONTIER) FMPC See Section 4.7 on page 85

5 [A1] Stand-alone Version-Up in SP with DI Print/Data Writing Software [C4/C5] Client Installation

SP See Section 4.9 on page 87

6 Restarting SP(Connection error message may appear after restarting, but this causes no problems )

SP

7 IEEE1394 Driver Pre-installation FMPC See Section 4.10 on page 89

8 Installing IEEE1394 Driver for SP in FMPC FMPC See Section 4.11 on page 90

9 Starting-up LP in ROM Mode and Checking ROM Version (2.0-0X-000)

LP See Section 4.12 on page 90

10 Installing IEEE1394 Driver for LP in FMPC FMPC See Section 4.13 on page 91

11 FMPC [D20] Installation (User Version-up) FMPC See Section 4.14 on page 92

12 Restarting FMPC FMPC

13 Enabling of “Rack Auto Cleaning” SP See Section 4.20 on page 99

14 Paper Condition Setup FMPC See Section 4.21 on page 99

15 Creating Backup FD for FMPC, SP1500/2000 and LP1500/2000

FMPC/SP/LP/IC See Section 4.22 on page 100

16 Operational Check FMPC/SP/LP/IC See Section 4.23 on page 101

17 System Shutdown SP/FMPC/IC See Section 4.24 on page 101

77

Page 78: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC SP

distributed by www.minilablaser.com

(See “2.2 PC Preparations”)

For the installing procedures for 1394 board, See 2.2.1 IEEE1394 Board Installation .

To minimize the waiting time for installation, select “No” for “Rack Auto cleaning” in “[46B] Rack Auto

Cleaning”. (In case of updating from FMPC Ver.1.0, perform this setting in FMPC.)

After the installation, set to No again.

4.2 PC Preparations

4.3 Disabling of “Rack Auto Cleaning”

78

Page 79: Fuji FRONTIER 350 370 SERVICE MANUAL

SP FMPC

distributed by www.minilablaser.com

1 Set to “No” for “Rack Auto Cleaning.

2 Select “4 Setup and Maintenance” - “1 System Operation Setup and Check ” - “7 Data Backup ”

3 Prepare a data backup floppy disk “SP1500/SP2000” or “LP1500/LP2000”.

4 Insert a disk into the floppy drive of the main control unit.

5 Move the cursor to the “Destination” box and select “Scanner”, “Printer” or “Pricing Unit”.

NOTE:Perform pricing data backup into the hard disk when pricing unit data is changed.

6 Click [OK].

• “Making the backup of the data” message

appears.

7 Upon completion of the backup, press the [Cancel] button.

8 Insert the FRONTIER 350/370 System (A1) Disk into the CD-ROM drive.

9 Perform the post-operational checks, then shut down the FRONTIER.

10 In case of updating, use the same procedures as the above to perform creating backup FD for FMPC.

4.4 Creating Backup FD for SP1500/2000, LP1500/2000

FRONTIER 350/370 System Disk (A1)

GD1621

79

Page 80: Fuji FRONTIER 350 370 SERVICE MANUAL

LP

distributed by www.minilablaser.com

[ROM Replacement]Replace the ROM on the CTL 20 circuit board with

an adaptable ROM for FMPC.

1 Set the power switch to STANDBY, and turn OFF the built-in circuit breaker and the main supply.

2 Remove the fourteen screws and then take off the printer control section cover.

3 Remove the five screws and open the control CB bracket.

4 Replace the ROM U16 (40 pins) on the CTL 20 circuit board with the adaptable ROM for FMPC.

5 Close the control CB bracket, and then reinstall the printer control section cover.

4.5 Replacing the ROM for Printer

Printer Control Section Cover

Screws (14)

EZ783

Control CircuitBoard Bracket Screws (5)

EZ177

FMPC Adaptable ROM4D005+*

80

Page 81: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC SP LP

distributed by www.minilablaser.com

(1) IEEE1394 Cable Preparation

Bind the bared part of the existing IEEE1394 cable

connected between the printer (LP) and scanner

(SP).

1 Remove the scanner rear cover by loosening the four screws and removing the fifteen screws.

2 Remove the clamp screw and then disconnect the IEEE1394 cable from the scanner (SP).

3 Remove the clamp from the cable.

4 Bind the bared part of the cable with insulating tape.

4.6 Connecting FMPC, FRONTIER, LAN Cable and Monitor Switcher

Screws(4)(Loosen)

Screws(15)(Remove)

Scanner Rear Cover

EZ900

Clamp Screw

IEEE1394 Cable

MP004

Clamp

Insulating Tape

IEEE1394 Cable

MP006

81

Page 82: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC SP LP

distributed by www.minilablaser.com

(2) IEEE 1394 Cable Connection Preparations

1 Connect the Printer (LP) to the FMPC with the existing IEEE1394 cable (10m) that connected the Printer (LP) to the Scanner (SP).

2 Connect the Scanner (SP) to the FMPC with the IEEE1394 cable (4.5m).

IMPORTANTDo not connect the two cables to the same board in the FMPC.

IMPORTANTMake sure that the IEEE 1394 cable from scanner (SP) is connected to the lower board, and the cable from printer (LP) to the upper board.

FMPC

Printer (LP)

Existing IEEE1394 Cable (10m)

IEEE1394 Cable (4.5m)

Scanner (SP)

IEEE1394 Connectors

82

Page 83: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC SP LP

distributed by www.minilablaser.com

(3) Monitor Switcher Connections

Connect the FMPC, monitor switcher, and FRONTIER as follows.

It is recommended that the monitor switcher be installed under the monitor.

Scanner (SP)

Monitor Switcher

Monitor

MP007

83

Page 84: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC SP LP

distributed by www.minilablaser.com

(4) Other Connections

Connect the FMPC, FRONTIER and the monitor switcher and then connect the LAN cable from the HUB to

which the Imaging Controller is connected. as shown in the following connection diagram.

FRONTIER (SP)

Monitor Switcher

(Front)

(Back)

Main Control Unit (SP)

5

3

1

2

5

3

1

2

4

4

FMPC

Power Supply

Keyboard

Mouse

Keyboard Cable from the SPExtension Cable for Keyboard

To Imaging Controller

HUB

IMPORTANTConnect the monitor’s power cable to the power supply directly. Do not connect the scanner’s power connector.

84

Page 85: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC SP LP

distributed by www.minilablaser.com

(5) Cable Routing

After the connections are completed, route the cables from FRONTIER as shown below.

Turn on the FMPC, then log on with the password “FRONTIER”.

IMPORTANTIf the FMPC Ver.1.0 is already installed, start up the FMPC while pressing the [Shift] key.(Start pressing the [Shift] key just when the Windows XP logo appears.)

4.7 Turning on FMPC

Mouse Cable

Serial Cable for Monitor Switcher

LAN Cable

Cable Bracket

Keyboard/Mouse Cable from the front Keyboard Extention Cable

Keyboard Cable

MP016

NMP010

85

Page 86: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

Disable the 1394 network connection on SP side.

1 Select [Start] - [Control Panel], then click the [Network Connections].

2 Right-click on the 1394 Connection whose status is “Enabled”, then set it to “Disabled”.

IMPORTANTCheck the setting as follows: 1394 Connection on SP: Disabled1394 Connection on LP: Enabled

3 Set to "Disabled" for another connection using the same procedure.

The number of connection varies depending on your system.

4.8 Disabling Network Connection on SP Side

86

Page 87: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

1 Press the scanner’s START switch to start up the FRONTIER.

• The installer starts and the “[L-001] Simple

Upgrade” screen appears.

2 Click the [OK] button.

• The “Procedure Selection 1 [C-001]” screen

appears.

3 Select “SE maintenance” and click the [Next] button.

• The “Procedure Selection 2 [C-002]” screen

appears.

4 Select “Update stand-alone scanner”, and click the [Next] button.

5 In the confirmation dialog, click the [Yes] button.

6 Click the [Next] button.

4.9[A1] Stand-alone Upgrade in SP [Ver.1.5 -> Ver.1.7] and

DI Print/Data Writing Software [C4/C5] Client Installation in SP

87

Page 88: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

• Copying starts.

7 Select “Inherit data from former version on HD”, and click the [Next] button.

8 In the confirmation dialog, click the [OK] button.

9 In the complete dialog, click the [OK] button.

10 Remove the CD from the CD drive, then restart the scanner (SP).

NOTE:The connection error message may appear after restarting, but this causes no problems.

11 Insert the DI Print/Data Writing Software[C4/C5] installer CD into the CD drive of the FMPC, then start the installation.

After restarting, the connection error message may appear, but this causes no problems.

88

Page 89: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

1 Insert the FMPC driver CD into the CD-ROM, then in the “Device Drivers Disk [D-01]” dialog box, click the [OK] button. This completes the FMPC driver disk setup.

If the driver disk is not started up automatically, run “N:\EZ171\Setup.exe.” (“N:\” varies depending on your system.)

2 When the FMPC driver disk setup is completed normally, the “Device Drivers Disk [D-02]” dialog box appears. Remove the driver disk from the CD-ROM drive, then click the [OK] button to shut down the system. After shutdown, turn on the FMPC.

NOTE:If the FMPC Ver.1.0 is already installed, start up the FMPC while pressing the [Shift] key.(Start pressing the [Shift] key just when the Windows XP logo appears.)

4.10 IEEE1394 Driver Pre-installation

89

Page 90: Fuji FRONTIER 350 370 SERVICE MANUAL

LPFMPC

distributed by www.minilablaser.com

1 On the “Found New Hardware Wizard” screen, click the [Next] button.

2 On the “Completing the Found...” screen, click the [Finish] button. This completes the installation of the driver for LP-5700 normally.

3 On the Desktop, select [Start] - [Control Panel] - [System] - [Hardware] tab - [Device Manager], and then check if “1394 Client Device (For Scanner)” exists under “1394 Client Device”.

1 Start up the printer (LP) in the ROM mode. During the countdown press [MENU - [<-] - [->] - [Enter] in this order, then check that the ROM Version is displayed on the panel, then check if the ROM Version is “(2.0-0x-000)”.

4.11 Installing IEEE1394 Driver for SP in FMPC

4.12 Starting-up LP in ROM Mode and Checking ROM Version (2.0-0x-000)

[ ROM Version ]2.0-0X-000 >

90

Page 91: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

1 On the “Found New Hardware Wizard” screen, click the [Next] button.

2 On the “Completing the Found...” screen, click the [Finish] button. This completes the installation of the driver for LP-5700 normally.

3 On the Desktop, select [Start] - [Control Panel] - [System] - [Hardware] tab - [Device Manager], and then check if “1394 Client Device (For Printer)” exists under “1394 Client Device”.

4.13 Installing IEEE1394 Driver for LP in FMPC

91

Page 92: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

Install the FMPC software in the dedicated PC.

NOTE:Before the installation, check if the ROM version is displayed in the operation panel in LP.

1 Insert the FMPC installer CD into the CD drive.

2 The FMPC installer program is automatically started up.If the installer program is not started up, perform the following procedures.(1) Move to [EZ171] folder in the CD drive.

(2) Double-click [setup.exe].

3 In the “Procedure Selection (A-001)” screen, select “Re-installation”, then click the [Next] button.

In case of updating from Ver.1.0 to Ver.2.0, select "User Versionup".

4 In the “Starting Re-installation (A-100)” dialog, click the [Yes] button.

5 In the “Information (A-110)” dialog, click the [OK] button.

4.14 FMPC [D20] Software Installation (Reinstall) with Printer's Backup FD

NMP012

92

Page 93: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

6 On the “Printer Selection” screen, select “LP1500/LP2000”, then click the [Next] button.

7 Installation is started.

8 In the “FD Confirmation (A-117)” dialog, click the [Yes] button.

NOTE:In this case, select [NO] because the FMPC backup FD is not prepared yet.

9 In the “Inserting Backup FD (A-120)” dialog, click the [No] button.

NOTE:In this case, select [NO] because the FMPC backup FD is not prepared yet.

10 In the “Inserting Printer’s Backup FD (A-130)” dialog, click the [Yes] button.

11 The “Information” dialog appears.

12 Insert the Printer’s Backup FD for LP into the FD drive of the FMPC PC.

13 Click the [OK] button.

Click.

NMP014

93

Page 94: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

14 On the “Input Source Selection [A-135]” screen, select [SP1500/SP2000], then click the [Next] button.

15 Remove the FD from the FD drive.

16 In the “Re-installation Completion(A-140)” dialog, click the [OK] button.

17 In the “Setup Completion (A-150)” dialog, click the [OK] button.

IMPORTANTDo not restart the printer (LP). If it is restarted, all parameters are initialized.

18 Proceed to “4.15 DI Print/Data Writing Software Installation in FMPC”.

NMP015

94

Page 95: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

Install the DI Print/Data Writing [C4/C5] Client.

1 Replace the FMPC installer CD with the C4/C5 installer CD.

2 Browse [Start] - [Shut Down], then select [Restart] to restart the PC.

3 After the PC is restarted, the C4/C5 installer screen appears. Click the [Next] button.

4 On the “Start Copying Files” screen, click the [Next] button.

5 Installation is started.

6 On the “...Wizard Complete” screen, select “Yes, I want to...”, then click the [Finish] button.

4.15 DI Print/Data Writing Software [C4/C5] Client Installation in FMPC

NMP012

95

Page 96: Fuji FRONTIER 350 370 SERVICE MANUAL

FMPC

distributed by www.minilablaser.com

7 Remove the C4/C5 installer CD from the CD drive.

8 On the “Install Shield Wizard Complete” screen, select “Yes, I will restart...”, then click the [Finish] button.

After the FMPC is restarted, the LP parameter downloading message I-2305 appears.

1 Open the "4 Setup and Maintenance" screen with “SE2” (Password : 7777).

2 Select “1) System Condition Setup and Check” - “2) Installation Information Setup”, then set up the “Delivery Date” and “Setup Date”, and then click the [OK] button.

NOTE:If the settings are changed, restarting of SP is required to activate the new settings.

For the delivery and setup dates of printer, check “41F Installation Information Setup” in the scanner (SP).

NMP013

4.16 Installation Information Setup for FMPC

96

Page 97: Fuji FRONTIER 350 370 SERVICE MANUAL

SP

distributed by www.minilablaser.com

1 Restart the SP(Scanner), then open "Setup and Maintenance" - "System Condition Setup and Check" - "Installation Information Setup", and select "FMP Controller" as Output Device, then click the [OK] button.

2 Select [350] or [370] for "System Name".(This selection is not required in case of SP-3000.)

Default: 370

3 Restart the SP.

NOTE:If the settings are changed, restarting of SP is required to activate the new settings.

To check the delivery and setup dates of printer, select “ON” in “Output Device”.

4.17 Output Device Setup for SP and Restarting SP

97

Page 98: Fuji FRONTIER 350 370 SERVICE MANUAL

SP FMPC

distributed by www.minilablaser.com

Copy the print size table from the SP to the FD by

using the dedicated print size setting tool. Then,

copying it to the FMPC.

(1) Copy Table to FD

1 Insert the print size setting tool FD into the FD drive of SP1500/2000, open the Explorer, then execute “PrintsizeSetTool.exe” in FD.

2 When the FRONTIER model and System [A1] is proper, the following message appears. Click the [OK] button to start copying it to the system.

3 Copying the data from SP to FD is started.

4 After copying, the following message appears.

(2) Copy Table from FD to FMPC

1 Insert the print size setting tool FD into the FD drive of FMPC, open the “Explorer”, then double-click “PrintSizeSetTool.exe” in FD drive.When the connections are properly done, the following message appears. To start copying, click the [OK] button.

2 Another confirmation message appears. Click the [OK] button to start copying.

3 Data is copied from the FD to the FMPC.

4 When copying is completed, the following message appears.

4.18 Copying Print Size Table to FD then Copying LP1500/2000 Print Size Table to FMPC

98

Page 99: Fuji FRONTIER 350 370 SERVICE MANUAL

IC FMPC

distributed by www.minilablaser.com

See “3.20 FMPC Output Device Setting in Imaging Controller”.

When the installation process is completed, return “Rack Auto Cleaning” to “Yes” in “[46B] Processor

Operating Condition Setup” in FMPC.

Set up the paper condition in the FMPC.

4.19 FMPC Output Device Setting in Imaging Controller

4.20 Enabling of “Rack Auto Cleaning”

4.21 Paper Condition Setup

99

Page 100: Fuji FRONTIER 350 370 SERVICE MANUAL

SP FMPC

distributed by www.minilablaser.com

Back up the data both in the FMPC and

FRONTIER.

The following procedures are those used for the FMPC. Also, perform the same procedures for the FRONTIER.

[Selection]“4 Setup and Maintenance” - “1 System Operation

Setup and Check” - “7 Data Backup”

[Procedure]Make a backup of unit data stored in the hard disk

of the main control unit after changing the “Setup

and Maintenance” data in case unit data is

damaged.

1 Prepare the data backup floppy disk “FMPC” or “LP1500/LP2000”

2 Insert the disk into the floppy drive of the main control unit.

3 Move the cursor to the “Destination” box and select “MP Controller” or “Printer”

4 Click [OK]

• “Making the backup of the data” message

appears.

5 Upon completion of the backup, press the [Cancel] button.

• Operation returns to the “4 Setup and

Maintenance” screen.

6 Remove the FD from the drive.

4.22 Creating Backup FD for FMPC, SP1500/2000 and LP1500/2000

NMP014

NMP015

100

Page 101: Fuji FRONTIER 350 370 SERVICE MANUAL

SP FMPCIC

distributed by www.minilablaser.com

Perform the operational check. (See 2.21 Operational Check .)

For the procedures of film scanning in FRONTIER 350/370, see “5.1.2 Printing from FRONTIER (135-size film example)” in the Instruction Manual.

Shut down the SP1500/2000, FMPC, then Imaging Controller in this order.

This completes the FMPC installation and setup.

4.23 Operational Check

4.24 System Shutdown

101

Page 102: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

5 Maintenance Menu (FRONTIER 350/370/355/375)

1 Select “4 Setup and Maintenance” from the main menu.

2 Select “SE2” for the user name and enter “7777” for the password, and click the [OK] button.

• “SE1” user name is prepared for the user who manages printing quality. The password is “6666”.

• “SE2” user name is prepared for the service engineer.

• The “Setup and Maintenance” screen appears.

3 Select the desired item from the item list and press its [+] button.

• The sub-item list appears.

4 Move the cursor to the desired item and press the [START] button.

• Each screen appears.

5 Perform operations by following the instructions on the screen.

6 Upon completion of the setup and maintenance operations, press the [OK] button to perform processing or [Cancel] to quit the screen.

• Operation returns to the “Setup and Maintenance” screen.

7 Click the [END] .

8 Operation returns to the main menu.

5.1 Operational Procedure

102

Page 103: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.2.1 Production Information 1 (411)

[Selection]“4 Setup and Maintenance” - “1 System Operation

Setup and Check”. - “1 Production Information 1”.

[Procedure]The information can be changed by selecting

“Negative”, “Reversal”, “Digital Image” or “All” from

the “Input Type” box.

1 To clear the data, follow the steps below.

(1) Click [Clear].

• The “Clear production information?” dialog box appears.

(2) Click [OK].

• The production data is erased.

2 To save the data in FD, click [FD Save].

3 Insert the blank FD into the drive.

4 In the confirmation dialog box, click [OK].

5 After the data is saved, remove the FD from the drive.

6 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen.

7 Select the “END [1]” on the menu bar.

• Operation returns to the “Main Menu” screen.

This menu is convenient for saving the data in the FD periodically.

5.2 System Operation Setup and Check (41)

103

Page 104: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.2.2 Production Information 2 (412)

[Selection]“4 Setup and Maintenance” - “1 System Operation

Setup and Check” - “2 Production Information 2”

[Procedure]This menu is to view acumulative amount number

of production.

Confirm the production information for each input

type. The data can be cleared on this menu.

Input Type : Color Negative

Reversal

Black & White Negative

1 Record the production information.

2 To clear the data, follow the steps below.

(1) Use “Input Type” to choose which data you wish to clear.

(2) Then press click [Clear].

• The “Clear production information?” dialog box appears.

(3) Click [OK].

• The data is cleared and date of clearance appears.

3 To save the data in FD, click [FD Save].

4 Insert the blank FD into the drive.

5 In the confirmation dialog box, click [OK].

6 After the data is saved, remove the FD from the drive.

7 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen.

104

Page 105: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.2.3 Accumulated Production Information (413)

This procedure displays the production information.

The data can be cleared on this menu.

[Selection]“4 Setup and Maintenance” − “1 System Operation

Setup and Check” − “3 Accumulated Production

Information”

1 Select Negative, Reversal, Digital Image or All from the Input Type box.

• The information of the input type is displayed.

2 Record the accumulated production information.

3 To save the data to a floppy disk, perform the following steps.

(1) Click the [FD Save] button.

(2) Insert the formatted floppy disk into the floppy disk drive of the main control unit.

(3) Click the [OK] button.

• The data is saved into the floppy disk.

(4) Remove the floppy disk from the floppy disk drive.

5) Click the [OK] button.

• The dialog box disappears.

4 Click the [OK] button.

• Operation returns to the menu screen.

NMP014

NMP015

105

Page 106: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.2.4 Timer Setup (414)

[Selection]“4 Setup and Maintenance” - “1 System Operation

Setup and Check” - “4 Timer Setup”

[Procedure]The present date/time, timer ON date/time and

preheat setup times are setup.

1 To update “Present Date/Time”, change the date and time, and click [OK].

To cancel the update, press the [Cancel] button.

2 To change the timer date and time, check the day of the week and enter the time in the “Timer ON Date/Time Setting” box.

3 Setup the preheat timer by following steps in the next column, if necessary.

IMPORTANTThe ON time for a night-time preheating operation must not overlap with the ON time of the weekly timer since night-time preheating takes priority and shuts down all power when it is set OFF.If, for instance, the calendar timer is set to 5:00 and night-time preheating is turned ON at 3:30, all the power will be shut down two hours later at 5:30.

Night-time preheating is usually conducted when the room temperature drops below 10?C (50?F) at night and the temprature is not controlled for 8 or more hours.

(1) Select “YES” for “Preheat Setting”.

• The 1st and 2nd preheat setting boxes appear.

(2) Move the cursor to “1st Preheat” and enter the time.

(3) Move the cursor to “2nd Preheat” and enter the time.

• For preheating once only, set the same time for both the first and second times.

• Select “NO” when no the preheat timer is used.

• The second preheating timer is ignored if the first and second times overlap.

<Example>

1st. preheat time: 2:00

2nd. preheat time: 3:00

With the above settings, night-time preheating

will occur from 2:00 to 4:00 (2 hours).

4 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen.

106

Page 107: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.2.5 Error Information Check (415)

[Selection]“4 Setup and Maintenance” - “1 System Operation

Setup and Check” - “5 Error Information Check”

[Procedure]The system error log is listed up in order of date

and time.

1 Click [Log Info].

• The “Log File Re-reading Check” dialog box appears.

2 Click [OK].

• The log file is relorded.

3 Click [Accum. Info].

• Accumulated error information is displayed in order of code and frequency.

4 Click [Log Information].

• Operation returns to the “Error log information” screen.

5 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen.

107

Page 108: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.2.6 Installation Information Confirmation (416)

[Selection]“4 Setup and Maintenance” - “1 System Operation

Setup and Check” - “6 Installation Information

Confirmation”

[Procedure]Check the scanner and printer installation

information.

1 Check the installation information.

2 Click [Option].

3 Check the version of Frontier Manager, then click [OK].

4 Click [OK]

• Operation returns to the “4 Setup and Maintenance” screen.

5.2.7 Data Backup (417)

[Selection]“4 Setup and Maintenance” - “1 System Operation

Setup and Check” - “7 Data Backup”

[Procedure]Make a backup of the unit data stored in the hard

disk of the main control unit after changing the

“Setup and Maintenance” mode data in case unit

data is damaged.

1 Prepare the data backup floppy disk “FMPC” or “LP1500/LP2000”.

2 Insert the disk into the floppy drive of the main control unit.

3 Move the cursor to the “Destination” box and select “FMP Controller” or “Printer”.

4 Click [OK].

NMP014

108

Page 109: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

• “Making the backup of the data” message appears.

5 Upon completion of the backup, press the [Cancel] button.

• Operation returns to the “4 Setup and Maintenance” screen.

6 Remove the FD from the drive.

5.2.8 Clear Error Log (41E)

[Selection]Select “4 Setup and Maintenance” - “1 System

Operation Setup and Check” - “E Clear Error Log”. .

[Procedure]Clear unwanted system and printer error

information.

1 Select the item to be cleared and press the [Clear] button.

2 In the confirmation dialog, click the [OK] button.

• The selected information is cleared.

3 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

NMP015

109

Page 110: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.2.9 Installation Information Setup (41F)

[Selection]Select “4 Setup and Maintenance”-“1 System

Operation Setup and Check”-“F Installation

Information Setup”.

[Procedure]Set the installation information for printer.

5.2.10 DI Manager Administrative Setting (41l)

Set the time to delete the order that is completed on

the DI Controller.

[Selection]“4 Setup and Maintenance” - “1 System Operation

Setup and Check” - “I DI Manager Administrative

Setting”.

[Procedure]

1 Select the time to delete the order that is to be done on the DI Controller.

2 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen.

110

Page 111: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.3.1 Paper Condition Setup

When new paper is to be loaded, follow the

procedure described below to set up the new paper

condition.

[Selection]“4 Setup and Maintenance” - “2 Print Condition

Setup and Check” - “1 Paper Condition Setup”.

[Procedure]

1 Select the [Magazine Upper] or [Magazine Lower] to be set up.

2 Click [Print].

• After about 5 minutes, an upkeep print is delivered to the large-size tray.

Densitometer AD100:

Densitometer AD200:

3 After the condition setup print has come out, press the [Dens Measure] button.

4 Adjust the guide of the densitometer according to the width of the condition setup print.

Densitometer Operation Panel:

When an error occurs, press the orange [RESET] switch.

5.3 Print Condition Setup and Check (42)

Indicator Light Ready Measuring Error

Power (Green) On On On

Ready (Green) On Blinks Off

Error (Red) Off Off On

111

Page 112: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5 Insert the condition setup print into the densitometer.

6 Press the [START] button on the densitometer.

If the message below appears, click [OK] and repeat the density measurement from Step 6 .

• The measurement is automatically started and the density measurement result is displayed.

7 Click [OK].

• The density measurement result disappears.

If the “Density Measurement Result” is NG, the message below appears. Perform Steps 5 to 10 again until the result becomes OK.

8 Click [Cancel].

• The “4 Setup and Maintenance” screen appears.

9 Select the “END [1]” on the menu bar.

• Control returns to the “Main Menu”.

Densitometer

Upkeep PrintEZ635

[START] Button

EZ636

112

Page 113: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.3.2 Processing Solution Temperature Check

[Selection]“4 Setup and Maintenance” - “2 Print Condition

Setup and Check” - “2 Processor Temperature”.

[Procedure]

1 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen.

2 Select the “END [1]” on the menu bar.

• Control returns to the “Main Menu” screen.

5.3.3 Control Strip Processing

The processing solution performance is evaluated

by processing a control strip, measuring the

processed strip densities, and comparing them with

the reference strip densities.

■ Control Strip Preparation

1 Take the control strip package out of the freezer, and leave it for about one hour to bring it to room temperature.

2 Take the inner bag out of the control strip package and place it on the control strip holder, with its seamed surface up, and put them both in the dark box. Close the dark box cover.

EZ1841

Seamed Surface

Control Strip Holder

Control Strip Inner Bag

EZ740

113

Page 114: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

3 Pass your hands through the sleeves of the dark box, take one control strip out of the inner bag, and insert it into the control strip holder, as shown in the figure. Push it in until it reaches the far end.

4 Fold over the open end of the inner bag to prevent fogging of the unused control strips.

5 Take the control strip holder out of the dark box.

6 Return the control strip package to the freezer.

■ Control Strip Processing

[Selection]“4 Setup and Maintenance” - “2 Print Condition

Setup and Check” - “3 Control Strip Processing”.

[Procedure]

1 Click [OK] to start the control strip processing.

• The message “Processing the control strip.” appears.

• The message “Set Holder” appears on the operating panel on the printer.

2 Open the cover of the control strip holder port in the processor cover, and position the holder so that its “EMULSION SURFACE” mark faces the processor side.

3 Press the [ENTER] key on the operating panel of the printer.

Emulsion Surface Upward

Control StripEZ741

Control Strip Holder Port Cover

Control Strip Holder

Processor Cover

“EMULSION SURFACE” MarkEZ742

7.7

EZ625

114

Page 115: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

• The processor starts and control strip processing begins.

• After about 4 minutes, the control strip is fed out to the large size tray.

• The message “Control strip processing is completed.” appears on the screen.

4 Remove the control strip holder from the port in the processor cover.

5 Click [OK].

• The message is cleared.

6 Click [Cancel].

• Control returns to the “4 Setup and Maintenance” screen.

For the daily morning pre-operational checks, operation returns to the “Printing Condition Upkeep”.

7 Select the “END [1]” on the menu bar.

• Control returns to the “Main Menu” screen.

■ Control Strip Storage and Handling Precautions

REFRENCE:A control strip is used for checking the performance of the processing solutions. The package contents are composed of exposed but unprocessed paper strips, one reference strip (processed and used as the density reference), and the correction factor chart for the reference strip. Process a control strip once a day, measure the reflection densities (R,G,B) using a densitometer and check for processing solution performance.

IMPORTANT• Place the control strips inside a plastic bag and

store them in a freezer (-10°C/14°F or below). Storage at room temperatures leads to deterioration in performance.

• Moisture condensation occurs if the control strips are processed immediately after they have been taken out of freezer. This may give rise to uneven development.

• Do not open the folded end of the inner bag under any light, or the control strips may become fogged and rendered useless.

115

Page 116: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.3.4 Print Size Setup (424)

[Selection]“4 Setup and Maintenance” - “2 Print Condition

Setup and Check” - “4 Print Size Setup”

[Procedure]Set the print size to be used.

• Normally, the size is registered as shown in the table.

1 Select the print size to be modified or registered from the list.

• ID [No.], Name, Width, Length, Border, four BD values and [Display(ON/OFF)] are displayed.

2 Move the cursor to the print size to be used, select “ON” or “OFF” shown in the “Display”.

Print Sizes Registered in FMPC

• If you select “ON”, the description appears on the list. If you select “OFF”, nothing appears on the list.

IMPORTANTMake sure to register the sizes for index printing.

NOTE:Make sure that the size names in the FMPC are the same as in the FRONTIER.

NOTE:When registering the new size, make sure to restart the FMPC.

3 Click [OK]

• Operation returns to the “4 Setup and Maintenance” screen.

No. Name Width [0.1mm] Length [0.1mm] Display Border1 89C 890 1270 ON BL2 89P 890 2540 ON BL3 89H 890 1580 ON BL4 102C 1020 1520 ON BL5 102P 1020 2540 ON BL6 102H 1020 1780 ON BL7 3R 1270 890 ON BL8 3RBD 1270 890 OFF BD9 5R 1270 1780 OFF BL10 5RBD 1270 1780 OFF BD11 4R 1520 1020 OM BL12 4RBD 1520 1020 OFF BD13 6R 1520 2030 OFF BL14 6RW 1520 2160 OFF BL15 8R 2030 2540 ON BL16 8RW 2030 3050 OFF BL17 A5 2100 1480 OFF BL18 A4 2100 2970 OFF BL19 8R1 2540 2030 OFF BL

20 10R 2540 3050 OFF BL21 10RW 2540 3810 OFF BL22 3DSC 890 1190 OFF BL23 3DSCf 890 1270 OFF BD24 4DSC 1020 1360 OFF BL25 4DSCf 1020 1520 OFF BD26 5DSC 1270 1690 OFF BL27 5DSCf 1270 1780 OFF BD28 89Ix 890 1200 OFF BL29 CDIDX 1020 1200 OFF BL30 127Ix 1270 1200 OFF BL31 3.5x7 890 1780 OFF BL32 4x5 1020 1270 OFF BL33 4x8.5 1020 2160 OFF BL34 4x8 1020 2030 OFF BL

No. Name Width [0.1mm] Length [0.1mm] Display Border

116

Page 117: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.3.5 Paper Condition Method Setup (42J)

[Selection]Select “4 Setup and Maintenance”- “2 Print

Condition Setup and Check ”- “J Paper Condition

Method Setup”.

[Procedure]Set the paper condition setup type.

1 Select “YES” or “NO” for the “Ambient variable” correction .

2 Select “YES” or “NO” for the “Master magazine” registration .

3 If “YES” is selected for Step “2”, set the ID, width, paper and type for the master magazine.

4 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

5.3.6 Back Print Setup (42O)

IMPORTANTThis setting is available only for the DSC printing. For the film printing, perform the “Back Print Setup (42O)” in the scanner (SP).

[Selection]Select “4 Setup and Maintenance”-“2 Print

Condition Setup and Check”-“O Back Print Setup”.

[Procedure]

1 Select “NO” or “YES” for “Back Print”.

2 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

117

Page 118: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.4.1 Paper Magazine Registration (451)

[Selection]“4 Setup and Maintenance” - “5 Printer Adjustment/

Maintenance” - “1 Paper Magazine Registration”

[Procedure]Register the Paper Magazine to be used.

1 Open the paper magazine by releasing the latch.

2 Remove the two screws and adjust the paper guide width in accordance with the paper width.

Do not loosen the red-painted screws.

3 Remove the two screws and adjust the flange width in accordance with the paper width.

5.4 Printer Adjustment/Maintenance (45)

LatchEZ643

Paper GuideScrews (2)

EZ854

Paper Shaft

Screws (2)

FlangeEZ855

118

Page 119: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

4 Select a paper ID referring to the table below, and enter the data.

To register paper not listed in the table, use an unused magazine ID.

5 Click [Set].

6 Install the ID chip on the paper magazine with the two screws.

7 Click [OK]

• Operation returns to the “4 Setup and Maintenance” screen.

1 89 Glossy A 180 180 55.0 62.02 102 Glossy A 180 180 55.0 62.03 117 Glossy A 180 180 55.0 62.04 127 Glossy A 180 180 55.0 62.05 152 Glossy A 180 180 55.0 62.06 89 Glossy A 180 180 55.0 62.07 102 Glossy A 180 180 55.0 62.08 117 Glossy A 180 180 55.0 62.09 127 Glossy A 180 180 55.0 62.010 152 Glossy A 180 180 55.0 62.011 203 Glossy A 90 90 55.0 67.012 210 Glossy A 90 90 55.0 67.013 254 Glossy A 90 90 55.0 67.014 203 Glossy A 90 90 55.0 67.015 152 Glossy A 180 180 55.0 62.016 254 Glossy A 90 90 55.0 67.018 254 Glossy A 90 90 55.0 67.0

MagazineID

PaperPaperWidth(mm)

Paper Length

(m)

LeftLength

(m)

Type DryingTemp.(°C)

LP1500SC LP2000SC

Screws (2)EZ1218

119

Page 120: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.4.2 Paper Feed Length Adjustment (452)

[Selection]Select “4 Setup and Maintenance”-“5 Printer

Adjustment/Maintenance”-“2 Paper Feed Length

Adjustment”.

[Procedure]Adjust the paper feed length.

1 Select the ID number of the magazine to be adjusted from the list on the screen and click it.

2 Make sure the value in the “Set value (feed length)” is “254.0”.

3 Enter the fine adjustment feed length value indicated on the label attached to the magazine in the “Fine adjust value” box.

4 On Menu “453 Test Pattern Printing”, make two prints with 127mm and 381mm feed lengths.

5 Measure the feed lengths of the prints fed out and calculate the increment using the formula below.

Increment = 254 – (Measured Value of

381mm – Measured Value of 127mm)

<Example>

Measured Value of 381mm = 380.0mm

Measured Value of 127mm = 126.4mm

Increment = 254 – (380 – 126.4) = 0.4

6 Add the increment to the value in “Fine adjust value” and enter it in the “Fine adjust value” box.

<Example>

Fine adjust value = 1.0mm

Increment = 0.4mm

New Fine Adjust Value = 1.0 + 0.4 = 1.4

7 With Menu “453 Test Pattern Printing”, make a print with a 127.0mm feed length.

8 Measure the feed length of the print fed out and calculate the offset increment using the formula below.

Offset Increment = 127–Measured Value of

127mm

<Example>

Measured Value of 127mm =126.6mm

Offset Increment Value = 127–126.6 = 0.4mm

9 Add the offset increment to the value in “Offset value” and enter it in the “Offset value” box.

10 Repeat Steps 1 to 9 for all paper magazines.

11 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen

120

Page 121: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.4.3 Test Pattern Printing (453)

[Selection]Select “4 Setup and Maintenance” - “5 Printer

Adjustment/Maintenance”- “3 Test Pattern Printing”.

[Procedure]Create the test pattern prints.

1 Move the cursor to the “Test pattern selection”, and select “Grid”, “Borderless contact”, “Bordered contact”, “Gradation” or “Step wedge”.

Grid

Borderless contact

Bordered contact

Gradation Step wedge

121

Page 122: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

2 Move the cursor to the “Feed length” and enter “254” (mm).

3 Click the [Print] button.

• The message “Printing the test pattern print” appears.

• After about 5 minutes, the print is output to the large size tray.

4 Move the cursor to the “Magazine”, select another magazine and press the [Print] button.

Perform test pattern prints for all the magazines to be used.

5 Use the magnifying lens (X25) to check that the vertical lines for judging the color skew are within 1/8 pixel width, and the horizontal lines within 1/4 pixel width.

REFERENCE:

1 pixel width = 0.08mm

6 Click the [End] button.

• Operation returns to the “Setup and Maintenance” screen.

5.4.4 G, B Laser (SHG) Optimal Temperature Setup (454)

[Selection]“4 Setup and Maintenance” - “5 Printer Adjustment/

Maintenance” - “4 G, B Laser (SHG) Optimal

Temperature Setup”

[Procedure]Setup the G, B laser (SHG) optimal temperature.

NOTE:Perform this menu two hours after the LD has been ON. This provides sufficient time for the laser to warm up.

1 Click [Enter].

• The optimal temperature setup is started, and the result is displayed after 5 minutes.

2 Click [End].

• Operation returns to the “4 Setup and Maintenance” screen.

122

Page 123: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.4.5 Paper Feed (455)

[Selection]“4 Setup and Maintenance” - “5 Printer Adjustment/

Maintenance” - “5 Paper Feed”

[Procedure]Paper is fed without printing.

1 Set the number of prints, feed length and select magazine.

Quantity : 1 to 999Feed Lengh : 82.5 to 381.0

2 Click [OK].

• Paper is fed.

3 Click [End].

• Operation returns to the “4 Setup and Maintenance” screen.

5.4.6 Printer Temperature Display (456)

[Selection]“4 Setup and Maintenance” - “5 Printer Adjustment/

Maintenance” - “6 Printer Temperature Display”

[Procedure]Printer temperature and its status are displayed.

NOTE:The temperatures are updated every 5 seconds.Keep the “Abnormal temp. detection” to “ON”.

1 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen.

123

Page 124: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.4.7 Printer Input Check (457)

[Selection]“4 Setup and Maintenance” - “5 Printer Adjustment/

Maintenance” - “7 Printer Input Check”

[Procedure]Check the status of the sensors.

1 Click [End].

• Operation returns to the “4 Setup and Maintenance” screen.

5.4.8 Image Position Fine Adjustment (458)

[Selection]“4 Setup and Maintenance” - “5 Printer Adjustment/

Maintenance” - “8 Image Position Fine Adjustment”

[Procedure]Adjustment of the image position for each paper

magazine.

1 Make a bordered print to be adjusted.

2 Select the paper magazine for print to be adjusted.

3 Check that the image is in the center of paper.

4 If necessary, adjust by following the steps below.

(1) On Menu 424 “Print Size Setup”, enter initial bordered width (4.0mm or 5.0mm) in “Upper BD”, “Lower BD”, “Left BD” and “Right BD” columns (see Subsection 9.3.4).

(2) To move the image in the feed direction, decrease the value in the “Sub-scanning”.

(3) To move the image in the reverse direction, increase the value in the “Sub-scanning”.

(4) To move the image in the rear direction, decrease the value in the “Main scanning”.

(5) To move the image in the front direction, increase the value in the “Main scanning”.

124

Page 125: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

Adjusting Range: -30mm to 30mm

5 Click [Set].

6 Click [End].

• Operation returns to the “4 Setup and Maintenance” screen.

5.4.9 Printer I/O Check (45A)

[Selection]Select “4 Setup and Maintenance”- “5 Printer

Adjustment/Maintenance”- “A Printer I/O Check”.

[Procedure]Check the operation of the motors and solenoids,

and status of the sensors.

The distribution section moves to the following position by choosing the button.[Waiting] : Waiting position[Rise] : Distribution position[Decent] : Absorption position

125

Page 126: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

1 Click any buttons of the operation commands.

• The selected operation is driven.

2 Click the [Cancel] button.

• Operation returns to the “Setup and Maintenance” screen.

5.4.10 Printer Function Select (45B)

[Selection]Select “4 Setup and Maintenance” -“5 Printer

Adjustment/Maintenance ”- “B Printer Function

Select”.

[Procedure]Set the distribution function.

1 Select “YES” or “NO” for “Distribution”.

2 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen.

126

Page 127: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.4.11 Laser Exposure Check (45C)

[Selection]Select “4 Setup and Maintenance” - “5 Printer

Adjustment/Maintenance”- “C Laser Exposure

Check”.

[Procedure]Perform the RGB test exposure and check the

operation.

1 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

5.4.12 R Laser (R-LD) Data (45D)

[Selection]Select “4 Setup and Maintenance” - “5 Printer

Adjustment/Maintenance” - “D R Laser(R-LD)

Data”.

[Procedure]Display the R laser (R-LD) data on the EEPROM.

1 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

127

Page 128: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.4.13 G Laser (G-SHG) Data (45E)

[Selection]Select “4 Setup and Maintenance” - “5 Printer

Adjustment/Maintenance” - “E G Laser (G-SHG)

Data”.

[Procedure]Display the G laser (G-SHG) data on the EEPROM.

1 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

5.4.14 B Laser (B-SHG) Data (45F)

[Selection]Select “4 Setup and Maintenance” - “5 Printer

Adjustment/Maintenance” - “F B Laser (B-SHG)

Data”.

[Procedure]Display the B laser (B-SHG) data on the EEPROM.

1 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

128

Page 129: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.4.15 Scanning Position/Scanning Home Position Parameter Setup (45G)

[Selection]Select “4 Setup and Maintenance” - “5 Printer

Adjustment/Maintenance” - “G Scanning Position/

Scanning Home Position Parameter Setup”.

[Procedure]Display the parameters for exposure positions.

1 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

5.4.16 Main Scanning Position Adjustment/Laser Beam Sync. Rough Adjustment (45H)

[Selection]Select “4 Setup and Maintenance” - “5 Printer

Adjustment/Maintenance” - “H Main Scanning

Position Adjustment/Laser Beam Sync. Rough

Adjustment”.

[Procedure]Perform the scanning adjustment and laser beam

synchronization rough adjustment.

1 Click the [OK] button.

129

Page 130: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

• After about 5 minutes, the print is output to the large size tray.

2 Measure A, B and C shown on the screen and record each value.

Accuracy: 0.5mm

3 Move the cursor to the “A: Left measured value” and enter “A” value.

4 Move the cursor to the “B: Right measured value” and enter “B” value.

5 Press the [Enter] button.

6 Move the cursor to the “C: Top measured value” and enter “C” value.

7 Click the [Enter] button.

8 Find the best X coordinate which has the least color skew on the output print for the vertical lines using the magnifier (x20-40), and enter the coordinate value and the drifted color (CMY) order from the left-hand side.

9 Find the best Y coordinate which has the least color skew on the output print for the horizontal lines using the magnifier (x20-40), and enter the coordinate value and drifted color (CMY) order from the top.

10 Move the cursor to the “X(Width)” and enter the measured “X” value

11 Move the cursor to the “Y(Width)” and enter the measured “Y” value.

12 Press the [Enter] button of the “Coordinate” with least amount of color drift .

13 Click the [End] button.

• Operation returns to the “Setup and Maintenance” screen.

A B

C

Sub-scanning (Horizontal) Line

Main Scanning (Vertical) Line

Laser Beam Synchronizing Adjustment Block

130

Page 131: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.4.17 Laser Beam Sync. Fine Adjustment Print (45J)

[Selection]Select “4 Setup and Maintence”-“5 Printer

Adjustment/Maintenance”-“J Laser Beam Sync.

Fine Adjustment Print”.

[Procedure]Perform the fine adjustment of the laser beam

synchronization.

1 Move the cursor to the “Order of drifted colors for main scanning” and enter the measured X value measured in “Main Scanning Position Adjustment/Laser Beam Sync. Rough Adjustment (Menu 45H)”.

2 Move the cursor to the “Order of drifted colors for sub-scanning” and enter the measured Y value measured in “Main Scanning Position Adjustment/Laser Beam Sync. Rough Adjustment (Menu 45H)”.

3 Click the [Print] button.

• The print is output to the large-size tray.

4 Find the best XY coordinate which has the least color skew on the output print for the horizontal lines using the magnifier (x20-40), and enter its number.

5 Move the cursor to the “Best main scanning position” and enter its number.

6 Move the cursor to the “Best sub-scanning position” and enter its number.

7 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

131

Page 132: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.4.18 Laser History Display (45K)

[Selection]Select “4 Setup and Maintence”-“5 Printer

Adjustment/Maintenance”-“K Laser History

Display”.

[Procedure]Display the exposure time and current value of R-

LD, G-SHG and B-SHG.

1 Click the [Switch display] to switch between the graph and numeric displays.

2 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

5.4.19 Paper Condition Setup Table (LUT) Copy (45L)

[Selection]Select “4 Setup and Maintence”-“5 Printer

Adjustment/Maintenance”-“L Paper Condition

Setup Table (LUT) Copy”.

[Procedure]Copy the LUT (Look-up Table) between magazines.

1 Specify the ID of the source magazine.

2 Specify the ID of the destination magazine.

3 Click the [OK] button.

• The copy is performed and operation returns to the “Setup and Maintenance” screen.

132

Page 133: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.4.20 Printer Mechanism Fine Adjustment (45M)

[Selection]Select “4 Setup and Maintence”-“5 Printer

Adjustment/Maintenance”-“M Printer Mechanism

Fine Adjustment”.

[Procedure]Perform fine adjustment of the width guide,

distribution section and the sub-scanning motor

speed.

<Input Unit>

Width guide : mm

Bottom : pulse

2-line rear : pulse

2-line front : pulse

Top : pulse

3-line rear : pulse

3-line front : pulse

Subscan motor speed: 0.1%

1 Refer to the “Paper Width Guide Adjustment” for Width guide.

2 Enter the adjustment values indicated on the labels attached to the distribution unit for the Distribution section boxes.

Enter the “Front Up/Down Section Adjustment” value in the “Top” box.

3 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

3-line Front

2-line Front

3-line Rear 2-line Rear

BottomEZ1599

133

Page 134: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.4.21 Back Printer Test (45N)

[Selection]Select “4 Setup and Maintence”-“5 Printer

Adjustment/Maintenance”-“N Back Printer Test”.

[Procedure]Perform the test print of the back printer.

1 Set the “Q’ty” and “Feed length”.

2 Select the magazine to be used.

• The test print is output to the large-size tray.

3 Click the [Cancel] button.

• Operation returns to the “Setup and Maintenance” screen.

5.4.22 Printer Operation Data Display (45P)

[Selection]Select “4 Setup and Maintenance”- “5 Printer

Adjustment/Maintenance” - “P Printer Operation

Data Display”.

[Procedure]Check printer operation data.

1 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

134

Page 135: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.4.23 Data Saving (45T)

[Selection]Select “4 Setup and Maintence”-“5 Printer

Adjustment/Maintenance”-“T Data Saving”.

[Procedure]Store the printer data into the hard disk of the main

control unit.

1 Select item to be saved.

2 Click the [OK] button.

• Data is saved.

• Operation returns to the “Setup and Maintenance” screen.

5.4.24 Data Download (45U)

[Selection]Select “4 Setup and Maintence”-“5 Printer

Adjustment/Maintenance”-“U Data Download”.

[Procedure]Download the printer data into the printer.

1 Select item to be downloaded.

2 Click the [OK] button.

• Data is downloaded.

3 Click Press the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

135

Page 136: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.4.25 Precut Length Setting (45V)

[Selection]Select “4 Setup and Maintence”-“5 Printer

Adjustment/Maintenance”-“V Precut Length

Setting”.

[Procedure]Set the precut length.

1 Enter the numeric value of the precut length.

2 Click the [End] button.

• Value is registered.

• Operation returns to the “Setup and Maintenance” screen.

136

Page 137: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.5.1 Replenisher Pump Output Measurement

If the replenisher pump output is reduced, improper

processing and drop in level of solution in the

processing tank may result.

Processing solutions may irritate the eyes and skin. When handling processing solutions, wear protective goggles, a rubber apron, rubber gloves, rubber boots and other protective gear as appropriate to prevent any solution from coming in contact with the body. Always wash hands well after handling processing solutions.

[Selection]“4 Setup and Maintenance” - “6 Processor

Adjustment/Maintenance” - “1 Pump Output

Measurement/Setting”.

[Procedure]

1 Prepare a measuring cylinder.

2 Remove the sub-tank cover.

3 Click [Start] of the “PS-R” box.

• The alarm beeps intermittently for 10 seconds.

Click [Cancel] to stop the operation.

4 Before the pump starts discharging, disconnect the PS-R replenisher nozzle and insert it into the measuring cylinder.

5.5 Processor Adjustment/Maintenance (46)

Sub-tank CoverEZ679

PS-R Replenisher Nozzle

Measuring CylinderEZ747

137

Page 138: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

• The replenisher pump starts discharging after the alarm beeps for 10 seconds.

• The alarm beeps when discharging is completed.

5 Insert the PS-R replenisher nozzle into the PS sub-tank.

6 Place the measuring cylinder on a level surface, then read and record the output.

7 Pour the replenisher solution from the measuring cylinder into the waste recovery tank.

8 Select the “Measured value” box for “PS-R” using the mouse or field key, and enter the recorded output value using numeric keys or the [ ↑ ] and [ ↓ ] keys.

The machine automatically measures and adjusts the pump outputs for P1-R, P2-RA and P2-RB.

9 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen.

10 Select the “END [1]” on the menu bar.

• Control returns to the “Main Menu” screen.

11 Reinstall the sub-tank cover.

12 Clean the measuring cylinder.

5.5.2 Auto-cleaning Pump Output Measurement

If the auto-cleaning pump output is reduced,

improper processing and drop in processing tank

solution may result.

Processing solutions may irritate the eyes and skin. When handling processing solutions, wear protective goggles, a rubber apron, rubber gloves, rubber boots and other protective gear, as appropriate, to prevent any solution from coming in contact with the body. Always wash hands well after handling the processing solutions.

[Selection]“4 Setup and Maintenance” - “6 Processor

Adjustment/Maintenance” - “2 Auto-cleaning Output

Measurement/Setting”

[Procedure]

1 Prepare two measuring vessels to measure the auto-cleaning pump output.

2 Remove the processor cover.

Processor CoverEZ685

138

Page 139: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

3 Remove the dryer entrance rack cover.

4 Release the lock and remove the No.1 crossover rack.

5 Release the locking hook and remove the two auto-cleaning nozzles from the No.1 crossover rack.

6 Drain the auto-cleaning nozzles.

7 Install each auto-cleaning nozzle into a measuring vessel.

8 Install the measuring vessels on the processing rack by aligning their rubber joints with the washing solution tank holes.

If the rubber joints are not installed properly, the replenisher solution will splash.

Push in each measuring cup until its locking hook engages the rack. If it is installed improperly, the replenisher solution will splash.

Dryer Entrance Rack Cover

EZ690

Lock Release Lever

No.1 Crossover Rack

EZ686

No.1 Crossover Rack

Auto-cleaning Nozzles (2)

Locking hook

EZ687

Auto-cleaning Nozzle

EZ1071

Measuring Vessel

Auto-cleaning Nozzle

EZ1067

Measuring Vessel

Rubber JointEZ1068

139

Page 140: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

9 Click [Start] for “P1”.

• The alarm beeps intermittently for 10 seconds.

Click [Cancel] to stop the operation.

• The alarm beeps once when the discharging is completed.

10 Remove the measuring vessels by releasing the locks.

11 Hold the measuring vessels upright, read both vessels, add up the total volume and record it.

12 Discard the solution.

13 Reinstall the washing nozzles into the No.1 crossover rack, and reinstall the crossover rack on the P1 processing rack.

14 Select “Measured value” for “P1”, and enter the recorded output value using numeric keys or the [ ↑ ] and [ ↓ ] keys.

15 Select “P2”, “PS1”, and “PS3”, and perform Steps 11 through 16 for them successively.

16 Click [OK].

• Control returns to the “4 Setup and Maintenance” screen.

17 Select the “END [1]” on the menu bar.

• Control returns to the “Main Menu” screen.

18 Reinstall the dryer entrance rack cover and the processor cover.

Lock Release Lever

Measuring Vessel

EZ1069

Measuring Vessels

EZ1070

140

Page 141: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.5.3 Processing Temperature Setting (463)

[Selection]“4 Setup and Maintenance” - “6 Processor

Adjustment/Maintenance” - “3 Processing

Temperature Setting”

[Procedure]Set the processing temperatures.

1 Enter the numerical values of the “P1”, “P2” and “PS” processing temperatures.

2 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen.

5.5.4 Replenisher Rate Setup (464)

[Selection]“4 Setup and Maintenance” - “6 Processor

Adjustment/Maintenance” - “4 Replenisher Rate

Setting”

[Procedure]Set the replenishment amount.

1 Enter the numerical values of the “P1-R”, “P2-R” and “PS-R” replenishment amount.

2 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen.

Range Default Value

P1 30.0 to 40.0 38.5

P2 30.0 to 40.0 38.0

PS 30.0 to 40.0 38.0

Range Default Value

P1-R 30.0 to 200.0 45.0

P2-R 20.0 to 300.0 35.0

PS-R 100.0 to 300.0 150.0

141

Page 142: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.5.5 Evaporation Correction Rate Setting (465)

[Selection]“4 Setup and Maintenance” - “6 Processor

Adjustment/Maintenance” - “5 Evaporation

Correction Rate Setting”

[Procedure]Set the evaporation correction rate.

1 Select “YES” to “Evaporation Correction”, and “Standard” to “Humidity”.

2 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen.

5.5.6 Low Volume Setting (466)

[Selection]“4 Setup and Maintenance” - “6 Processor

Adjustment/Maintenance” - “6 Low volume Setting”

[Procedure]Set the low volume processing data.

1 Select “YES” to “Low volume”.

2 Enter value in the “Min. processing amount” box.

Range : 0.0 to 15.0

3 Enter value in the “Min. processing amount (last 8 days)” box.

Range : 0.0 to 99.9

4 To clear the data, press the [Clear] button.

5 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen.

142

Page 143: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.5.7 Processor Temperature Calibration (467)

[Selection]“4 Setup and Maintenance” - “6 Processor

Adjustment/Maintenance” - “7 Processor

Temperature Calibration”

[Procedure]Perform the processor section temperature

calibrations.

1 Check that the display values reach the “Setting” temperatures.

2 Turn the P1 filter holder 90° counterclockwise, remove the P1 circulation filter and place it on the tray.

Do not let the solution drip or run.

3 Measure the temperature of the processing solution and record it.

4 Reinstall the filter by aligning the fastening tab with the notch, and turn it 90° clockwise.

5 If the “Setting” temperatures differ from the values displayed, move the cursor to the “Measured value” and enter the values recorded in Step 3.

Range : 0.0 to 99.9

6 Click [Enter].

7 For P2, PS2 and PS4, perform Steps 1 through 6.

P1 Filter Holder

EZ680

EZ749

Filter Holder notch

Fastening Tab

EZ682

143

Page 144: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

8 Click [OK].

• Operation returns to the “4 Setup and Maintenance” screen.

5.5.8 Processor Input Check (468)

[Selection]“4 Setup and Maintenance” - “6 Processor

Adjustment/Maintenance” - “8 Processor Input

Check”

[Procedure]Check the status of the sensors.

1 Click [End].

• Operation returns to the “4 Setup and Maintenance” screen.

144

Page 145: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.5.9 Processor I/O Check (46A)

[Selection]Select “4 Setup and Maintence”-“6 Processor

Adjustment/Maintenence“-“A Processor I/O Check”.

[Procedure]Check the operation of the motors and solenoids,

and status of the sensors.

• The status of each part is displayed in realtime.

1 Press any of the operation command buttons.

• The selected operation is driven.

2 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

145

Page 146: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.5.10 Processor Operating Condition Setup (46B)

[Selection]Select “4 Setup and Maintence”-“6 Processor

Adjustment/Maintenence”-“B Processor Operating

Condition Setup”.

[Procedure]Set the processor’s operating condition.

1 Select “YES” or “NO” for the dryer section preheat driving.

2 Select “YES” or “NO” for the rack auto cleaning.

3 Select “YES” or “NO” for the auto intermittent driving.

4 Select “YES” or “NO” for the paper feed-out switch.

5 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

5.5.11 Processor Operation Data Display (46C)

[Selection]Select “4 Setup and Maintenance” - “6 Processor

Adjustment/Maintenance” - “C Processor Operation

Data Display”.

[Procedure]The processor operation data is displayed. This

data can be cleared on Menu 46D.

1 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

146

Page 147: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.5.12 Processor Operation Data Display 2 (46E)

[Selection]Select “4 Setup and Maintenance” - “6 Processor

Adjustment/Maintenance” - “E Processor Operation

Data Display 2”.

[Procedure]The processor operation data is displayed. This

data can be cleared on Menu 46D.

1 Click the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

147

Page 148: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.6.1 Paint (48A)

[Selection]Select “4 Setup and Maintence”-“8 Special

Operations”-“A Paint”.

[Procedure]Use the “Paint”.

For operations of the “Paint”, see the WindowsR XP manual.

1 Click the [X] button in the upper right-hand corner of the screen.

NOTE:Be sure not to press the emergency button.

• Operation returns to the “Setup and Maintenance” screen.

5.6.2 Explorer (48B)

[Selection]Select “4 Setup and Maintence”-“8 Special

Operations”-“B Explorer”.

[Procedure]Use the “Explorer”.

For operations of the Explorer , see the WindowsR XP manual.

1 Click the [X] button in the upper right-hand corner of the screen.

Be sure not to press the emergency button.

• Operation returns to the “Setup and Maintenance” screen.

5.6 Special Operations (48)

148

Page 149: Fuji FRONTIER 350 370 SERVICE MANUAL

F350/370/355/375

distributed by www.minilablaser.com

5.6.3 Command (48C)

[Selection]Select “4 Setup and Maintence”-“8 Special

Operations”-“C Command”.

[Procedure]Perform the MS-DOS command operations.

For operation of the “Command”, see the MS-DOS(TM) manual.

1 Click the [X] button in the upper right-hand corner of the screen.

• Operation returns to the “Setup and Maintenance” screen.

149

Page 150: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

6 Maintenance Menu (FRONTIER 570) F570

1 Select “4 Setup and Maintenance” from the main menu.

2 Select “SE2” for the user name and enter “7777” for the password, and click the [OK] button.

• “SE1” user name is prepared for the user who manages printing quality. The password is “6666”.

• “SE2” user name is prepared for the service engineer.

• The “Setup and Maintenance” screen appears.

3 Select the desired item from the item list and press its [+] button.

• The sub-item list appears

4 Move the cursor to the desired item and press the [START] button.

• Each screen appears.

5 Perform the operation by following the instructions on the screen.

6 Upon completion of the setup and maintenance operations, press the [OK] button to perform processing or [Cancel] to quit the screen.

• Operation returns to the “Setup and Maintenance” screen.

7 Click the [END] .

8 Operation returns to the main menu.

6.1 Operational Procedure

150

Page 151: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.2.1 Production Information 1 (411)

This procedure displays the production information.

The data can be cleared on this menu.

[Selection]“4 Setup and Maintenance” - “1 System Operation

Setup and Check” − “1 Production Information 1”

1 Select Negative, Reversal, Digital Image or All from the Input Type box.

• The information of the input type is displayed.

2 Record the production information.

3 To save the data to a floppy disk, perform the following steps.

1) Click the [FD Save] button.

2) Insert the formatted floppy disk into the floppy disk drive of the main control unit.

3) Click the [OK] button.

• The data is saved into the floppy disk.

4) Remove the floppy disk from the floppy disk drive.

5) Click the [OK] button.

• The dialog box disappears.

6.2 System Operation Setup and Check (1)

NMP014

NMP015

151

Page 152: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

4 To clear the data, perform the following steps.

1) Click the [Clear] button.

• The “Clear production information?” dialog box appears.

2) Click the [OK] button.

• The data is cleared and clearing date appears.

5 Click the [OK] button.

• Operation returns to the menu screen.

6.2.2 Production Information 2 (412)

This procedure displays the production information.

The data can be cleared on this menu.

[Selection]“4 Setup and Maintenance” − “1 System Operation

Setup and Check” − “2 Production Information 2”

1 Select Negative, Reversal, Digital Image or All from the Input Type box.

• The information of the input type is displayed.

2 Record the production information.

3 To save the data to a floppy disk, perform the following steps.

1) Click the [FD Save] button.

152

Page 153: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

2) Insert the formatted floppy disk into the floppy disk drive of the main control unit.

3) Click the [OK] button.

• The data is saved into the floppy disk.

4) Remove the floppy disk from the floppy disk drive.

5) Click the [OK] button.

• The dialog box disappears.

4 To clear the data, perform the following steps.

1) Click the [Clear] button.

• The “Clear production information?” dialog box appears.

2) Click the [OK] button.

• The data is cleared and clearing date appears.

5 Click the [OK] button.

• Operation returns to the menu screen.

NMP014

NMP015

153

Page 154: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.2.3 Accumulated Production Information (413)

This procedure displays the production information.

The data can be cleared on this menu.

[Selection]“4 Setup and Maintenance” − “1 System Operation

Setup and Check” − “3 Accumulated Production

Information”

1 Select Negative, Reversal, Digital Image or All from the Input Type box.

• The information of the input type is displayed.

2 Record the accumulated production information.

3 To save the data to a floppy disk, perform the following steps.

1) Click the [FD Save] button.

2) Insert the formatted floppy disk into the floppy disk drive of the main control unit.

3) Click the [OK] button.

• The data is saved into the floppy disk.

4) Remove the floppy disk from the floppy disk drive.

5) Click the [OK] button.

• The dialog box disappears.

4 Click the [OK] button.

• Operation returns to the menu screen.

NMP014

NMP015

154

Page 155: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.2.4 Timer Setup (414)

This procedure sets the present date/time, timer

ON date/time and preheat setup times.

[Selection]“4 Setup and Maintenance” − “1 System Operation

Setup and Check” − “4 Timer Setup”

1 To update “Present Date/Time”, change the date and time, and click the [OK] button.

• To cancel the update, click the [Cancel] button.

• If the OS uses the 24-hour system, “04 to 09” and “14 to 19” cannot be entered directly. Use the spin buttons to enter these hours.

2 To change the timer date and time, enter a checkmark, [✔] in the day of the week boxes and enter the time in the “Timer ON Date/Time Setting” box.

3 Set the preheat timer by performing the following steps, if necessary.

IMPORTANTThe ON time for a night-time preheating operation must not overlap with the ON time of the weekly timer since night-time preheating takes priority and shuts down all power when it is set OFF.If, for instance, the calendar timer is set to 5:00AM and night-time preheating is turned ON at 3:30AM, all the power will be shut down two hours later at 5:30AM.

Night-time preheating is usually conducted when the room temperature drops below 10°C (50°F) at night and the temperature is not controlled for 8 or more hours.

1) Select “YES” for “Preheat Setting”.

• The 1st and 2nd preheat setting boxes appear.

2) Move the cursor to “1st Preheat” and enter the time.

3) Move the cursor to “2nd Preheat” and enter the time.

NOTE:• For preheating once only, set the same time

for both the first and second times.• Select “NO” when the preheat timer is not

used.• The second preheating timer is ignored if the

first preheat time and second preheat time overlap.

<Example>

1st. pre-heat time: 2:00AM

2nd. pre-heat time: 3:00AMWith the above settings, night-time preheating will occur from 2:00AM to 4:00AM (2 hours).

4 Click the [OK] button.

• Operation returns to the menu screen.

155

Page 156: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.2.5 Error Information Check (415)

The system error log is listed up in order of date

and time.

[Selection]“4 Setup and Maintenance” − “1 System Operation

Setup and Check” − “5 Error Information Check”

1 Click the [Log Info.] button.

• The “Log File Re-reading Check” dialog box appears.

2 Click the [OK] button.

• The log file is read out and the latest information is displayed on the screen.

3 Click the [Accum. Info.] button.

• Accumulated error information is displayed in order of code.

4 Click the [OK] button.

• Operation returns to the menu screen.

156

Page 157: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.2.6 Installation Information Reference (416)

This procedure displays the scanner and printer

installation information.

[Selection]“4 Setup and Maintenance” − “1 System Operation

Setup and Check” − “6 Installation Information

Reference”

1 Check the installation information.

2 Click the [Option] button.

• The “Optional Device Reference” dialog box appears.

3 Click the [OK] button.

• The dialog box disappears.

4 Click the [OK] button.

• Operation returns to the menu screen.

6.2.7 Data Backup (417)

This procedure makes a backup of the data stored

on the hard disk of the main control unit when data,

indicated on the data sheet located inside the front

upper cover, is changed.

The backup floppy disks are used when reinstalling

or reverting to earlier system software.

[Selection]“4 Setup and Maintenance” − “1 System Operation

Setup and Check” − “7 Data Backup”

1 Prepare a new floppy disk for data backup when backing up data.

NOTE:A floppy disk is unnecessary for pricing unit data backup because data is backed up to the hard disk of the main control unit.

2 Insert the floppy disk into the floppy drive of the main control unit.

3 Move the cursor to the “Destination” box and select “FMP Controller” or “Printer”.

157

Page 158: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

4 Click the [OK] button.

• The “Making the backup of the data” message appears.

5 Upon completion of the backup, click the [Cancel] button.

• Operation returns to the menu screen.

6.2.8 Clear Error Log (41E)

This procedure clears the system error and printer

error information.

[Selection]“4 Setup and Maintenance” − “1 System Operation

Setup and Check” − “E Clear Error Log”

1 Select the item to be cleared and click the [Clear] button.

• The selected information is cleared.

2 Click the [OK] button.

• Operation returns to the menu screen.

158

Page 159: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.2.9 Installation Information Setup (41F)

This procedure sets the installation information.

After setting up, restart the system to activate the

new settings.

[Selection]“4 Setup and Maintenance” − “1 System Operation

Setup and Check” − “F Installation Information

Setup”

1 Set the delivery date, startup date and lab ID.

2 Make sure that Input Device and Output Device are set as follows.Intput Device: SP-3000 (V1.7-)Output Device: LP-5700

3 Click the [OK] button.

• Operation returns to the menu screen.

4 Perform the post-operational checks to shut down the system and then restart the system.

• The new settings are activated.

6.2.10 DI Manager Administrative Setting (41I)

This menu is used when connecting the optional

Imaging Controller.

[Selection]“4 Setup and Maintenance” − “1 System Operation

Setup and Check” − “I DI Manager Administrative

Setting”

“Delete Waiting Time”: Sets up the time until the

order processed on the Imaging Controller is

deleted.

1 Set up the logical device name as follows.

<Example>

2 Click the [OK] button.

Logical Device Name

Device Name

Printer (sRGB) sRGBFMPC LP-5700

Printer (F-COLOR/PD) PDFMPC LP-5700

159

Page 160: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.3.1 Paper Condition Setup (421)

When new paper is to be loaded, follow this

procedure to set up the new paper condition.

[Selection]“4 Setup and Maintenance” − “2 Print Condition

Setup and Check” − “1 Paper Condition Setup”

1 Install the paper magazine to be set up and select “Magazine (upper)” or “Magazine (lower)”.

Click the [Initialize] button to initialize condition setup data.

2 Click the [Print] button.

• After about three minutes, a condition setup print is fed out.

Condition Setup Print

3 Adjust the guide of the densitometer according to the width of the condition setup print.

If an error occurs, press the orange [RESET] switch.

4 Insert the condition setup print into the densitometer.

6.3 Print Condition Setup and Check (2)

Densitometer Guide

EZ634

Densitometer

[START] Button

L2997

160

Page 161: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

5 Click the [Dens. Measure] button.

• The measurement is started and the density measurement result is displayed.

6 Click the [OK] button.

• The density measurement result dialog box disappears.

NOTE:If the “Density Measurement Result” is not acceptable, the message shown below appears. Repeat Steps 2 to 6 until the result becomes OK.

7 Click the [Close] button.

• Operation returns to the menu screen.

161

Page 162: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.3.2 Print Size Setup (424)

This procedure sets the print size to be used.

[Selection]“4 Setup and Maintenance” − “2 Print Condition

Setup and Check” − “4 Print Size Setup”

Normally, sizes are registered as shown in the table below.

No. Print Size Width [0.1mm] Length [0.1mm] Display Border1 89C 89.0 127.0 ON BL2 89P 89.0 254.0 ON BL3 89H 89.0 158.0 ON BL4 102C 102.0 152.0 ON BL5 102P 102.0 254.0 ON BL6 102H 102.0 178.0 ON BL7 3R 127.0 89.0 ON BL8 3RBD 127.0 89.0 OFF BD9 5R 127.0 178.0 OFF BL

10 5RBD 127.0 178.0 OFF BD11 4R 152.0 102.0 ON BL12 4RBD 152.0 102.0 OFF BD13 6R 152.0 203.0 OFF BL14 6RW 152.0 216.0 OFF BL15 8R 203.0 254.0 ON BL16 8RW 203.0 305.0 OFF BL17 A5 210.0 148.0 OFF BL18 A4 210.0 297.0 OFF BL19 8R1 254.0 203.0 OFF BL20 10R 254.0 305.0 OFF BL21 10RW 254.0 381.0 OFF BL22 11 X 14 279.0 356.0 OFF BL23 11 X 17 279.0 432.0 OFF BL24 12 X 10 305.0 254.0 OFF BL25 12 X 15 305.0 381.0 ON BL26 12 X 18 305.0 457.0 OFF BL27 3DSC 89.0 119.0 OFF BL28 3DSCf 89.0 127.0 OFF BD29 4DSC 102.0 136.0 OFF BL30 4DSCf 102.0 152.0 OFF BD31 5DSC 127.0 169.0 OFF BL32 5DSCf 127.0 178.0 OFF BD33 89lx 89.0 120.0 OFF BL34 CDIDX 102.0 120.0 OFF BL35 127lx 127.0 120.0 OFF BL

162

Page 163: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

1 Select the print size to be modified or registered from the list.

• ID [No.], Name, Width, Length, Border, four BD values and [Display (ON/OFF)] are displayed.

2 Move the cursor to the print size to be used, select “ON” or “OFF” shown in the “Display”.

• If you select “ON”, the description appears in the list. If you select “OFF”, nothing appears in the list.

3 Click the [OK] button.

• Operation returns to the menu screen.

6.3.3 Paper Condition Method Setup (42J)

This procedure sets the paper condition setup

method.

[Selection]“4 Setup and Maintenance” − “2 Print Condition

Setup and Check” − “J Paper Condition Method

Setup”.

↓ [Next page] [Prev. page] ↑

↓ [Next page] [Prev. page] ↑

163

Page 164: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

1 Select “YES” or “NO” for the ambient variable correction.

2 Select “YES” or “NO” for the master magazine registration.

3 If “YES” is selected in Step 2, set the ID, width, paper and type for the master magazine.

NOTE:• Ambient variable correction: When there is a

sudden change in temperature during the day, it influences the color formation stability of color papers. To maintain constant printing quality in that condition, select “YES”.

• Master magazine registration: Paper condition setup must be performed for all papers if NO is selected.

4 Click the [Next Page] button, then enter the password “1234”, and then click the [OK] button.

5 Enter “Density correction value” for “Patch No.” and “Temperature correction value” of the AD300 densitometer, if necessary.

6 Click the [Set] button.

7 Click the [OK] button.

• Operation returns to the menu screen.

6.3.4 Back Printing Setup (42O)

IMPORTANTThis setting is available only for the DSC printing. For the film printing, perform the “Back Print Setup (42O)” in the scanner (SP).

[Selection]Select “4 Setup and Maintenance” − “2 Print

Condition Setup and Check” − “O Back Print

Setup”.

[Procedure]

1 Select “NO” or “YES” for “Back Print”.

2 Choose the [OK] button.

• Operation returns to the “Setup and Maintenance” screen.

164

Page 165: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.3.5 Paper Surfaces Display Setup (42R)

Set the surface name display.

[Selection]“4 Setup and Maintenance” − “2 Print Condition

Setup and Check” − “R Print Surfaces Display

Setup”

165

Page 166: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.1 Paper Magazine Registration (451)

This procedure registers the paper magazine to be

used.

Change the dryer temperature if necessary.

[Selection]“4 Setup and Maintenance” − “5 Print Condition

Setup and Check” − “1 Paper Magazine

Registration”

↓ [Next page] [Prev. page] ↑

ID : Enter the magazine ID.

Width : Enter the paper width (mm).

Paper : Select the paper surface type.

Length : Enter the roll paper length (m).

Remain : Enter remaining paper length (m).

BP : Select “YES” or “NO” for back

printing.

Line speed : Selected automatically according to

the “Type”.

Type : Select the paper type correctly. The

paper type is indicated on the paper

package.

[Set] button : Click this button to register the

entered items.

ID : Enter the magazine ID.

P1R : Enter the P1R replenishment rate.

P2R : Enter the P2R replenishment rate.

PSR : Enter the PSR replenishment rate.

Correct value:Enter the correction value of the

dryer temperature.

[Set] button : Click this button to register the

entered items.

Do not change the “P1R“, “P2R”, “PSR” and “Correct value” values.

1 Release the latches and open the paper magazine.

6.4 Printer Adjustment/Maintenance (5)

Paper Magazine

Latches (2)

L2360

166

Page 167: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

2 Remove the two screws and adjust the width of the paper guides. Tighten the two screws.

Use the appropriate guides for paper width. Guide C is available as an optional accessory.

3 Loosen the four screws securing the paper flanges to the paper shaft.

4 Align the holes in the paper flange bosses with the paper width marks visible from the hole and tighten the four screws.

NOTE:Be careful not to overtighten the screws.

5 Find the appropriate paper from the table on the screen and install its ID chip to the magazine using the screw.

6 Click the [Close] button.

• Operation returns to the menu screen.

Guide Paper Width

A Except B and C

B 95/120/130/210

C 114/216

Screws (2)Paper Guides

L2361

L2367

Screws (4)

Paper Flanges

Hole/Width Mark

L2368

ID Chip

ScrewL2366

167

Page 168: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.2 Paper Magazine Feeding Fine Adjustment (452)

This menu should be executed for all paper

magazines when installing the machine, or when a

new magazine is registered.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “2 Paper Magazine Feeding Fine

Adjustment”

<Auto Adjustment>

1 Set a new magazine on the upper magazine deck.

2 Select “Upper” for “Magazine”.

3 Click the [Print] button.

• After about three minutes, Prints 1 and 2 are output to the sorter.

4 Enter new magazine ID in the “Magazine ID” box.

5 Measure the feed lengths of Prints 1 and 2 at the center and record them.

6 Enter the feed lengths recorded in the “Print 1” and “Print 2” boxes.

7 Click the [Set] button.

• Feed length is adjusted automatically.

8 Install the magazine in the upper deck to the lower deck.

9 Repeat Steps 3 through 7 for the lower magazine.

10 Click the [Close] button.

• Operation returns to the menu screen.

Print 1

Print 2

168

Page 169: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

<Manual Adjustment>

1 Enter the magazine ID to be adjusted in the “Magazine ID” box.

2 Select “Upper deck” or “Lower deck”.

3 Enter the value (mm) in the “New value” box.

4 Click the [Set] button.

• The feed length is changed.

5 Click the [Close] button.

• Operation returns to the menu screen.

6.4.3 Test Pattern Printing (453)

This procedure creates test pattern prints.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “3 Test Pattern Printing”

1 Move the cursor to “Test pattern selection”, and select “Grid”, “Borderless contact”, “Bordered contact”, “Gradation”, “Back print 1 (wedge)”, “Back print 2 (line)”, “Back print 3 (character)” or “Frame print”.

2 Move the cursor to “Length” and enter the feed length (mm).

3 Move the cursor to “Q’ty” and enter the number of prints.

4 Click the [Print] button.

• After about three minutes, the print is output to the sorter.

■ Color Drift Inspection

1) Make a grid test print.2) Use a magnifying lens (X25) to check that the

vertical line for the color drift is 1/8 pixel or less in width, and the horizontal line is 1/4 pixel or less in width.Reference: 1 pixel width = 0.08mm

5 Click the [Close] button.

• Operation returns to the menu screen.

169

Page 170: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

Grid: For color drift and feed length inspection

Borderless contact: For exposure and processing unevenness inspection

Bordered contact: For exposure and processing unevenness, or white border inspection

Gradation: For gradation inspection

Back print 1 (wedge) Back print 2 (line) Back print 3 (character)

Frame print

170

Page 171: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.4 G Laser (SHG) Optimal Temperature Setup (454)

The G laser optimal temperature setting message

appears every three months. Set up the optimal

temperatures on this screen.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “4 G Laser (SHG) Optimal

Temperature Setup”

1 Click the [Enter] button.

• The result is displayed.

2 Click the [Close] button.

• Operation returns to the menu screen.

171

Page 172: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.5 Paper Feed (455)

This procedure feeds and processes unexposed

sheets of paper.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “5 Paper Feed”

1 Enter the number of sheets in “Q’ty” box and the feed length in “Length” box.

Number of sheets: 1 to 999

Feed length: 82.5 to 381.0

2 Click the [Enter] button.

• The sheets of paper are fed and processed.

3 Click the [Close] button.

• Operation returns to the menu screen.

6.4.6 Printer Temperature Display (456)

This procedure displays the printer temperature

and printer status.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “6 Printer Temperature Display”

NOTE:The temperatures are updated every five seconds.

Always keep “ON” for “Working” of “Abnormal

temp. detection”.

1 Click the [Close] button.

• Operation returns to the menu screen.

172

Page 173: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.7 Printer Input Check (457)

This procedure displays the status of the sensors.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “7 Printer Input Check”

↓ [Next page] [Prev. page] ↑

1 Click the [Close] button.

• Operation returns to the menu screen.

6.4.8 Image Position and Tilt Fine Adjustment (458)

This procedure adjusts the white border and image

position in a template for each magazine ID.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “8 Image Position and Tilt Fine

Adjustment”

1 Install the paper magazine to be adjusted on the upper paper deck.

2 Select “Upper” or Lower for “Magazine”.

3 Enter the feed length to be adjusted in the “Feed length” box.

4 Click the [Print] button.

• After about three minutes, the adjustment print is output.

5 Select the magazine ID to be adjusted.

173

Page 174: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6 Measure the “X”, “Y”, “d” and “f” dimensions of the adjustment print and record them.

7 Enter the recorded “X” and “Y” values (mm) in the appropriate “Main (X)” and “Sub (Y)” boxes.

8 Calculate “d - f” and enter the value in the “Tilt (d - f)” box.

9 Click the [Set] button.

10 Install the magazine to be adjusted on the lower magazine deck.

11 Select “Lower” for “Magazine”.

12 Repeat Steps 3 through 9.

13 Click the [Close] button.

• Operation returns to the menu screen.

6.4.9 Printer I/O Check (45A)

This procedure displays the status of the motors,

solenoids and sensors.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “A Printer I/O Check”

↓ [Next page] [Prev. page] ↑

↓ [Next page] [Prev. page] ↑

d

y

x

f

FeedingDirection

174

Page 175: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

↓ [Next page] [Prev. page] ↑

1 Click the required operation button.

• The respective motor or solenoid operates if it is normal.

2 Click the [Close] button.

• Operation returns to the menu screen.

6.4.10 Printer Function Select (45B)

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “B Printer Function Select”

1 Select “Both” for “Magazine” normally.

2 Select “YES” for “Registration”.

NOTE:Select “No” for “Registration” to use temporarily when the error “W-2414” or “W-2450” occurred.

3 Select “YES” for “Distribution”.

NOTE:Select “No” for “Distribution” to use temporarily when the error “W-2419” or “W-2455” occurred and adjust the pipe slider position of the distribution unit as described below. Large size prints cannot be printed.

1) Open the magazine door.2) Open the distribution section inner cover.3) Align the “ ”marks on the pipe slider and

the distribution unit.4) Close the distribution section inner cover.5) Close the magazine door.

175

Page 176: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

4 Select “No change” for “Cut interval”.

NOTE:When paper overlap feed has occurred, select “Change” for “Cut interval”. If the higher level is selected (from Level 1 to 3), the cut interval is increased and the processing ability is decreased.

5 Click the [OK] button.

• Operation returns to the menu screen.

6.4.11 Laser Exposure Check (45C)

This procedure performs an RGB test exposure

and displays the results.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “C Laser Exposure Check”

1 Click the [Close] button.

• Operation returns to the menu screen.

“ ” Marks

Pipe Slider

L21157

176

Page 177: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.12 R Laser (R-LD) Data (45D)

This procedure displays the R laser (R-LD) data in

the EEPROM.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “D R Laser (R-LD) Data”

1 Click the [Close] button.

• Operation returns to the menu screen.

6.4.13 G Laser (G-SHG) Data (45E)

This procedure displays the G laser (G-SHG) data

in the EEPROM.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “E G Laser (G-SHG) Data”

1 Click the [Close] button.

• Operation returns to the menu screen.

177

Page 178: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.14 B Laser (B-LD) Data (45F)

This procedure displays the B laser (B-LD) data in

the EEPROM.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “F B Laser (B-LD) Data”

1 Click the [Close] button.

• Operation returns to the menu screen.

6.4.15 Scan/Scan Home Position Parameter (45G)

This procedure displays the parameters for

exposure positions.

Normally parameter changing is unnecessary.

When the result of Menu 0547 “Main Scanning

Position Adjustment/Laser Beam Synchronous

Rough Adjustment” should be altered purposely,

change the parameters.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “G Scan/Scan Home Position

Parameter”

1 Enter the scanning position/scanning home position parameters by clicking the [ ] and [ ] buttons.

UnitMain scanning: PixelSub-scanning : Raster

2 Click the [Set] button to set the parameters.

3 Click the [OK] button.

• Operation returns to the menu screen.

178

Page 179: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.16 Main Scan/Laser Beam Sync. Rough Adjustment (45H)

This procedure performs the scanning adjustment

and laser beam synchronization rough adjustment.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “H Main Scan/Laser Beam Sync.

Rough Adjust”

Perform this adjustment after processing three or more sheets of paper because the feed length may not stabilize immediately after setting paper.

1 Install the paper magazine for the narrowest paper width being used.

2 Click the [Print] button.

• The print is output in about three minutes.

3 Measure the dimensions of A, B and C, then record them.

Tolerance of measurement: Within 0.5mm

4 Move the cursor to “A: Left measured value” and enter the measured A value.

5 Move the cursor to “B: Right measured value” and enter the measured B value.

6 Click the [Set] button of “Width direction (main scanning position)”.

7 Click the [OK] button.

8 Move the cursor to “C: Top measured value“ and enter the measured C value.

9 Click the [Set] button of “Feeding direction (sub-scanning position)”.

C

A → ← → ← B

←→

Sub-Scanning Line

Rough AdjustmentBlock

179

Page 180: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

10 Click the [OK] button.

11 Find the X coordinate which has the minimum color drift on the print for the vertical lines using an inverted magnifier (x20-40), and record the coordinate value and the drifted color (CMY) order from the left.

12 Check and record the drifted color (CMY) order of the sub-scanning line from the top using an inverted magnifier (x20-40).

13 Move the cursor to “X(Width)” and enter the measured X value.

14 Move the cursor to “Y(Feed)” and enter the measured Y value.

15 Click the [Set] button of “Coordinate with least amount of color drift”.

16 Click the [OK] button.

17 Click the [Close] button.

• Operation returns to the menu screen.

6.4.17 Laser Beam Sync. Fine Adjustment Print (45J)

This procedure performs the fine adjustment of the

laser beam synchronization.

[Selection]“4 Setup and Maintenance” − ”5 Printer Adjustment/

Maintenance” − “J Laser Beam Sync. Fine

Adjustment Print”

1 Move the cursor to “Order of drifted colors for main scanning” and enter the drifted color order from the left recorded in “Main Scanning Position Adjustment/Laser Beam Sync. Rough Adjustment (Menu 0547)”.

2 Move the cursor to “Order of drifted colors for sub-scanning” and enter the drifted color order from the top recorded in “Main Scanning Position Adjustment/Laser Beam Sync. Rough Adjustment (Menu 0547)”.

3 Click the [Print] button.

• The print is output in about three minutes.

180

Page 181: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

NOTE:The adjustment print has twenty or twenty-five vertical and horizontal lines.

4 Find numbers that have the minimum color drift on the output print for the vertical and horizontal lines using the magnifier (x20-40).

5 Move the cursor to the “Best main scanning position” and enter the number of the vertical lines found.

6 Move the cursor to the “Best sub-scanning position” and enter the number of the horizontal lines found.

7 Click the [Set] button.

8 Click the [OK] button.

9 Click the [Close] button.

• Operation returns to the menu screen.

6.4.18 Laser History Display (45K)

Display the exposure time and current value of R-

LD, G-SHG and B-SHG.

[Selection]“4 Setup and Maintence” − “5 Printer Adjustment/

Maintenance” − “K Laser History Display”

1 Click the [Switch display] button to switch between the graph and numeric displays.

2 Click the [Close] button.

• Operation returns to the menu screen.

181

Page 182: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.19 Paper Condition Setup Table (LUT) Copy (45L)

This procedure copies the LUT (Look-up Table)

from one magazine to another.

[Selection]“4 Setup and Maintence” − “5 Printer Adjustment/

Maintenance” − “L Paper Condition Setup

Table(LUT) Copy”

1 Specify the ID of the source magazine.

2 Specify the ID of the destination magazine.

3 Click the [Enter] button.

• Copying is performed.

4 Click the [OK] button.

5 Click the [Close] button.

• Operation returns to the menu screen.

6.4.20 Printer Mechanical Fine Adjustment (45M)

This procedure adjusts the printer mechanism.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “M Printer Mechanical Fine

Adjustment”

1 “Cutter: Feed motor stop timing”:Sets up the feed motor stop timing when supplying paper. Click the [Set] button.

2 “Eject: Right/left speed control start timing”:Sets up the speed control start timing of the M665 motor when feeding sheet paper with single lane. Click the [Set] button.

3 “Setup of precut length”:Sets up the leading end cut-off length of paper for each magazine when the new roll paper is set, or printing is performed after eight hours have elapsed from the last printing (rewinding paper). Click the [Set] button.

4 “Adjustment for distributing position”:Adjusts distribution position and nip timing for each magazine. Click the [Set] button.

5 Click the [Close] button.

• Operation returns to the menu screen.

182

Page 183: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.21 Printer Operation Data Display (45P)

This procedure displays the printer operation data.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “P Printer Operation Data Display”

↓ [Next page] [Prev. page] ↑

↓ [Next page] [Prev. page] ↑

1 Click the [Close] button.

• Operation returns to the menu screen.

6.4.22 Data Saving (45T)

The parameters displayed can be written from the

memory on the printer’s circuit board to the HD in

the main control unit.

[Selection]“4 Setup and Maintence” − “5 Printer Adjustment/

Maintenance” − “T Data Saving”

1 Select the item to be saved.

2 Click the [OK] button.

• The data is saved.

• Operation returns to the menu screen.

183

Page 184: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.23 Data Download (45U)

The parameters displayed can be written from the

HD in the main control unit to the memory on the

printer’s circuit board.

[Selection]“4 Setup and Maintence” − “5 Printer Adjustment/

Maintenance” − “U Data Download”

1 Select the item to be downloaded.

2 Click [OK].

• The data is downloaded.

3 Click the [OK] button.

• Operation returns to the menu screen.

4 Shut down and restart the system.

6.4.24 Filter Replacement History (45a)

The laser optical unit air filter replacement history is

displayed.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “a Filter Replacement History”

[Replace] button : Click this button when the filter

has been replaced.

[Initialize] button : Click this button to initialize the

replacement history.

1 Click the [Close] button.

• Operation returns to the menu screen.

184

Page 185: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.25 Feeding Position Sensor Fine Adjustment (45b)

This procedure adjusts paper leading end position

for supply process on the basis of the sensors.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “b Feeding Position Sensor Fine

Adjustment”

NOTE:Perform this procedure for both upper and lower magazine decks.

1 Select “Upper” or “Lower” for “Magazine”.

2 Click the [Print] button.

• After about three minutes, adjustment Prints 1 and 2 are output.

3 Measure the feed length of Prints 1 and 2 and record them.

4 Enter the recorded values in the “Measured” boxes for “Print 1” and “Print 2”.

5 Click the [Calculate] button.

• New adjustment values appear in the “Calculated” box.

6 Select “All IDs” or “Selected ID only”.

7 Enter ID in the “ID” box if “Selected ID only” is selected.

8 Enter new adjustment value in the “New” box.

9 Click the [Set] button.

10 Click the [Close] button.

• Operation returns to the menu screen.

185

Page 186: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.26 Image Position Initial Setting (45c)

This procedure sets up the initial image position for

all magazines.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “c Image Position Initial Setting”

1 Install the narrowest paper magazine on the upper deck and the widest paper magazine on the lower deck.

2 Click the [Print] button.

• After about three minutes, adjustment Prints 1 and 2 for the upper magazine and Print 3 for the lower magazine are output.

3 Print 1 : Measure the A to F dimensions and enter them in the appropriate boxes.

Print 2 : Measure the C and E dimensions and enter them in the appropriate boxes.

Print 3 : Measure the B to F dimensions and enter them in appropriate boxes.

4 Click the [Set] button.

5 Click the [Close] button.

• Operation returns to the menu screen.

BF

D

C C

D

E

A

EPrint 1

Print 2

B

C

D F

EPrint 3

186

Page 187: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.27 Sub-scan Feeding Speed Adjustment (45d)

This procedure adjusts the feeding speed of the

sub-scanning unit.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “d Sub-scan Feeding Speed

Adjustment”

1 Select “Upper” or “Lower” for “Magazine”.

2 Click the [Print] button.

• After about three minutes, the adjustment print is output.

3 Measure the “A” dimension of the adjustment print and record it.

4 Enter the recorded value in the “Measured” box.

5 Click the [Calculate] button.

• New adjustment value is displayed in the “Calculated (%)” box.

6 Enter the magazine ID in the “ID” box.

7 Enter the calculated value in the “New” box.

8 Click the [Set] button.

9 Click the [Close] button.

• Operation returns to the menu screen.

6.4.28 Sub-scanning Soft Nip Fine Adjustment (45e)

This procedure adjusts the soft nip timing, nip

position and motor current value of the sub-

scanning unit.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “e Sub-scanning Soft Nip Fine

Adjustment”

1 Enter the feed length in the “Feed length” box.

2 Select “Upper” or “Lower” for “Magazine”.

3 Click the [Print] button.

• After about three minutes, adjustment Prints 1 to 9 are output.

4 Select optimum prints for unevenness level at the leading and trailing ends from nine adjustment prints.

5 Enter the optimum print numbers in the “Tip No. 1 to 9” and “End No. 1 to 9” boxes.

6 Click the [Convert] button.

• Timing, new pulse adjustment and motor current values are displayed.

7 Select “Selected ID only” or “All IDs”.

187

Page 188: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

8 Enter the ID in the “Magazine ID” box if “Selected ID only” is selected.

9 Click the [Set] button for “Adjustment value”.

10 Click the [Set] button for “Motor current value”.

11 Click the [Close] button.

• Operation returns to the menu screen.

6.4.29 Sensor Calibration (Initial) (45f)

This procedure calibrates the paper sensors.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “f Sensor Calibration (Initial)”

D619 : Upper magazine splice sensor

D629 : Lower magazine splice sensor

D650 : Exposure section entrance paper sensor.

D653 : Exposure position paper sensor

1 Click the [ ] button to select the sensor to be calibrated.

2 Click the [Start] button.

• Date and result are displayed.

If the result is “NG”, the sensor should be replaced.

3 Click the [Close] button.

• Operation returns to the menu screen.

188

Page 189: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.4.30 Sensor Calibration (Daily) (45g)

This procedure sets up daily calibration of the

sensors.

[Selection]“4 Setup and Maintenance” − “5 Printer Adjustment/

Maintenance” − “g Sensor Calibration (Daily)”

• The calibration history is displayed in the lower box of the screen.

D619 : Upper magazine splice sensor

D629 : Lower magazine splice sensor

D650 : Exposure section entrance paper sensor

D653 : Exposure position paper sensor

1 Select “Yes” for “Daily Calibration” normally.

NOTE:Manual calibration can be used if “No” is selected.

2 Click the [Set] button.

3 Click the [Close] button.

• Operation returns to the menu screen.

<Electric Current Calibration for Sensors not to be

Calibrated Daily>

1 Select a sensor in the “Sensor No.” box.

2 Click the [Set] button.

3 Click the [Close] button.

• Operation returns to the menu screen.

189

Page 190: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.5.1 Replenisher Pump Output Measurement/Setting (461)

This procedure measures and corrects the

replenisher pump output.

Normally measure only PSR.

NOTE:The machine automatically measures and adjusts

the pump output for P1R, P2RA and P2RB.

When executing this menu to confirm pump

operation for the P1R, P2RA or P2RB, return the

discharged replenisher into the replenisher tank.

[Selection]“4 Setup and Maintenance” − “6 Processor

Adjustment/Maintenance” − “1 Pump Output

Measurement/Setting”

1 Prepare a measuring cylinder.

2 Perform the following steps for PSR.

1) Open the water supply port door.

2) Loosen the screw and remove the water supply port inner cover.

3 Perform the following steps for P1R, P2RA or P2RB.

1) Open the replenisher box door.

2) Remove the circulation filter tray.

6.5 Processor Adjustment/Maintenance (6)

Screw

Water Supply Port Inner Cover

LII1055

Circulation Filter TrayLII232

190

Page 191: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

3) Remove the screw and then the splash-prevention cover.

4 Click the [Start] button for the pump to be measured.

• The message below appears on the printer operation panel.

5 Press the [Enter] key on the printer operation panel.

• The alarm beeps intermittently for ten seconds.

NOTE:Click the [Cancel] button to stop the operation.

6 Before the pump starts discharging, disconnect the replenisher nozzle, insert it into the measuring cylinder and hold it at the same height as its setting position.

• The replenisher pump starts discharging after the countdown.

• The alarm beeps when discharging is completed.

7 Insert the replenisher nozzle into the sub-tank.

8 Place the measuring cylinder on a level surface, and then read and record the output.

9 PSR : Dispose of the liquid in the measuring cylinder.

P1R, P2RA or P2RB : Return the discharged replenisher into the replenisher tank through the cartridge box opening.

Screw

Splash-prevention CoverL21051

#PSR MEASURE

#START [YES] ?

PSR Replenisher Nozzle

Measuring Cylinder

L21050

P1R Replenisher Nozzle

Measuring Cylinder

P2RB Replenisher Nozzle

P2RA Replenisher Nozzle

P1W Replenisher Nozzle

L21052

191

Page 192: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

10 Select the “Measured value” box, and enter the recorded output value.

11 Clean the measuring cylinder.

12 Click the [OK] button.

• Operation returns to the menu screen.

13 Reinstall the removed parts.

6.5.2 Auto Cleaning Output Measurement/Setting (462)

This procedure measures and corrects auto-

cleaning pump output.

[Selection]“4 Setup and Maintenance” − “6 Processor

Adjustment/Maintenance” − “2 Auto Cleaning

Output Measurement/Setting”

1 Prepare the two measuring cups for auto-cleaning output measurement.

2 Open the dryer unit and support it with Stopper 2 (yellow).

3 Remove the No.2 crossover rack.

NOTE:Do not remove the other crossover racks to prevent splashing of washing water.

No.2 Crossover Rack

No.3 Crossover RackL21121

192

Page 193: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

4 Install the measuring cups instead of the No.2 crossover rack as shown.

5 Click the [Start] button for “No.2”.

• The message bellow appears on the printer operation panel.

6 Press the [Enter] key on the printer operation panel.

• The pump discharges washing water after the ten second countdown.

NOTE:To stop discharging, press the [Enter] key.

• The alarm beeps once when the discharging is completed.

7 Remove the measuring cups.

8 Place the measuring cups on a horizontal surface, read the liquid amount and record it.

9 Dispose of the water from the measuring cups.

10 Enter the recorded value in the “Measured value” box for the “No.2”.

11 Reinstall the No.2 crossover rack and remove the No.3 crossover rack.

12 Install the measuring cups instead of the No.3 crossover rack.

13 Repeat Steps 5 through 10 for No.3.

14 Reinstall the No.3 crossover rack.

15 Repeat Steps 5 and 6 for “Dryer entrance rack”.

Measuring Cups

L21116

#No.2 MEASURE

#START [YES] ?

Measuring Cups

L21117

Dryer Entrance Rack

L2236

193

Page 194: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

16 Remove the dryer entrance rack and check that it is wet completely with washing water.

17 Reinstall the dryer entrance rack and close the dryer unit.

18 Click the [OK] button.

• Operation returns to the menu screen.

6.5.3 Processing Temperature Setting (463)

This procedure sets the processing temperatures.

[Selection]“4 Setup and Maintenance” − “6 Processor

Adjustment/Maintenance” − “3 Processing

Temperature Setting”

1 Enter the numerical values of the “P1”, “P2” and “PS” processing temperatures.

2 Click the [OK] button.

• Operation returns to the menu screen.

Range Initial Value

P1 40.0 to 45.0 43.0

P2 35.0 to 45.0 43.0

PS 42.0 to 47.0 45.0

194

Page 195: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.5.4 Low Volume Processing Setup (466)

This procedure sets up low volume processing.

[Selection]“4 Setup and Maintenance” − “6 Processor

Adjustment/Maintenance” − “6 Low Volume

Processing Setup”

1 Select “YES” for “Low volume”.

2 Enter minimum processing amount in the box.

Range: 0.0 to 25.0

3 Enter minimum processing amount for the last eight days in the box.

Range: 0.0 to150.0

NOTE:Click the [Clear] button to clear all data.

4 Click the [OK] button.

• Operation returns to the menu screen.

6.5.5 Processor Temperature Calibration (467)

This procedure calibrates the processor section

temperatures.

[Selection]“4 Setup and Maintenance” − “6 Processor

Adjustment/Maintenance” − “7 Processor

Temperature Calibration”

1 Check that the display values have reached the “Setting” temperatures.

2 Open the dryer unit and support it with Stopper 2 (yellow).

3 Open the replenisher box door.

4 Remove the circulation filter tray.

P1 Circulation Filter

Circulation Filter TrayL2233

195

Page 196: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

5 Remove the P1 circulation filter and put it on the circulation filter tray.

6 Measure the temperature of the P1 processing solution and record it.

7 Reinstall the filter by aligning the fastening tab with the notch, and then turn it 90° clockwise.

8 If the “Setting” temperatures differ from the values displayed, move the cursor to the “Measured value” and enter the values recorded in Step 6.

Range: 0.0 to 99.9

9 Click the [Enter] button.

10 Repeat Steps 4 through 9 for the P2 solution temperature.

11 Measure the PS1/2/3 solution temperature at the PS2 processing tank and record it.

12 Repeat Steps 8 and 9 for the PS1/2/3 solution temperature.

13 Remove the water supply port inner cover and rubber plug from the PS4 sub-tank.

14 Measure the PS4 solution temperature and record it.

15 Repeat Steps 8 and 9 for the PS4 solution temperature.

16 Reinstall the rubber plug, water supply port inner cover and circulation filter tray.

17 Click the [Close] button.

• Operation returns to the menu screen.

ThermometerP1 Sub-tank

P2 Sub-tankL21047

Thermometer

PS2 Sub-tankL21048

PS4 Sub-tank

Thermometer

L21049

196

Page 197: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.5.6 Processor Input Check (468)

This procedure displays the status of the sensors.

[Selection]“4 Setup and Maintenance” − “6 Processor

Adjustment/Maintenance” − “8 Processor Input

Check”

↓ [Next page] [Prev. page] ↑

↓ [Next page] [Prev. page] ↑

1 Click the [Close] button.

• Operation returns to the menu screen.

6.5.7 Processor I/O Check (46A)

This procedure displays the status of the motors,

solenoids and sensors.

[Selection]“4 Setup and Maintenance” − “6 Processor

Adjustment/Maintenance” − “A Processor I/O

Check”

↓ [Next page] [Prev. page] ↑

↓ [Next page] [Prev. page] ↑

197

Page 198: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

1 Click the required operation button.

• The respective motor or solenoid operates, if it is normal.

2 Click the [Close] button.

• Operation returns to the menu screen.

6.5.8 Processor Operating Condition Setup (46B)

This procedure sets up the processor operating

condition.

[Selection]“4 Setup and Maintenance” − “6 Processor

Adjustment/Maintenance” − “B Processor

Operating Condition Setup”

1 Normally, the processor operating conditions are set up as shown in the table below.

2 Click the [OK] button.

• Operation returns to the menu screen.

Rack auto cleaning ON

Dryer entrance rack auto clean ON

No. of prints for dryer entrance rack auto clean 1 to 9999

1000

Auto intermittent driving ON

Forcible output to large size tray OFF

Energy saving mode ON

Ambient temperature correction ON

PS solution concentration monitor ON

Evaporation correction ON

Humidity Auto

PS rack cleaning OFF

Sorter Max. No. of sheets 50

Line speed for control strip High

198

Page 199: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.5.9 Processor Operation Data Display (46C)

This procedure displays the processor operation

data.

[Selection]“4 Setup and Maintenance” − “6 Processor

Adjustment/Maintenance” − “C Processor

Operation Data Display”

1 Click the [Close] button.

• Operation returns to the menu screen.

6.5.10 PS Liquid Concentration Management (46G)

[Selection]“4 Setup and Maintenance” − “6 Processor

Adjustment/Maintenance” − “G PS Liquid

Concentration Management”

1 Enter level in the “Measurement level” box.

Standard Level : 6

NOTE:The level may not be “6” according to the factory adjustment.

2 Click the [Set] button.

3 Click the [Start] button for “Manual measurement” .

• The required setting level is displayed in the “OK level” box.

4 Click the [Close] button.

• Operation returns to the menu screen.

199

Page 200: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.6.1 COM Port Setting (47A)

Set the serial communication port for the PU800BA.

[Selection]“4 Setup and Maintenance” − “7 Option Ajustment / Maintenance” − “A COM Port Setting”

6.6 Option Adjustment / Maintenance (7)

200

Page 201: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.7.1 Paint (49A)

Follow this procedure to use “Paint”.

[Selection]“4 Setup and Maintenance” − “9 Special

Operations” − “A Paint”

NOTE:For information on “Paint” operations, see the

Windows 2000 manual.

1 Click “File” and “Exit” in the upper left-hand corner of the screen.

NOTE:Be sure not to click the emergency button.

• Operation returns to the menu screen.

6.7.2 Explorer (49B)

Follow this procedure to use Explorer .

[Selection]“4 Setup and Maintenance” − “9 Special

Operations” − “B Explorer”

NOTE:For information on “Explorer” operations, see the

WindowsR 2000 manual.

1 Click “File” and “Exit” in the upper left-hand corner of the screen.

NOTE:Be sure not to click the emergency button.

• Operation returns to the menu screen.

6.7 Special Operations (9)

201

Page 202: Fuji FRONTIER 350 370 SERVICE MANUAL

F570

distributed by www.minilablaser.com

6.7.3 Command (49C)

Follow this procedure to perform MS-DOS

command operations.

[Selection]“4 Setup and Maintenance” − “9 Special

Operations” − ”C Command”

NOTE:For information on “Command” operations, see the

MS-DOSR manual.

1 Click the [X] button in the upper right-hand corner of the screen.

• Operation returns to the menu screen.

202

Page 203: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

7 Error Messages and Countermeasures

7.1.1 Message Number

The messages are identified by the following four

codes.

The first two digits indicate the location or operation

of the error occurred.

7.1.2 Message Icons

7.1.3 X-#### Actions

X-#### errors (software error)

Take the following actions.

1. Write down the error No.

2. Restart the system.

3. Reinstall the software if the problem persists.

4. Create the report in the specified format.

7.1 Error Indication Rule

Symbol Error

E Trouble (Error requires action of the service representative.)

W Mismatching of condition (Error can be corrected by the operator.)

I Information

X Software trouble

No. Error Location

11XX Scanner

12XX CTB20 circuit board

13XX Scanner image processing

14XX Film carrier

15XX Operation

21XX Scanner to printer interface

22XX Printer operation

23XX Printer control

24XX Paper feed

25XX Laser printer

26XX Processor

Icon Error

Errors with code “E” (Take measures after turning OFF the power supply.)

Errors with code “E” , “W” or “X” (Error can be recovered.)

For code “I” (Information)

203

Page 204: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

7.2 Messages

No Message Factor Actions

W-1402 Printer temperature adjustment not stabilized. perform pre-scan.

The printer laser temperature adjustment has not reached the specified value. (Not printed due to specification change)

W-1403 Processor temperature adjustment not stabilized. perform Pre-scan.

The temperature adjustments of the processing tanks have not attained the specified values. (Not printed due to specification change)

W-1406 "%MAGAZINE% not installed or paper end processing in progress. After green LED lights on magazine section door, install magazine and restart printing.

"Printing was performed without magazine installed.

W-1408 Back print cannot be performed with specified paper. Press [Continue] to perform printing without back print.

Back printing command was issued for the medium weight paper. During the normal printing, the magazine with the postcard ID was detected. 1. Wrong magazine was used, or

wrong print mode was selected.

2. Magazine ID sensor failure

3. Magazine malfunctions

1. Install the correct magazine or select the postcard printing mode.

2. Replace the magazine ID sensor.

3. Replace the magazine.

W-1418 %MAGAZINE% not installed or currently in paper end process. Install magazine and restart printing.

A magazine is not installed when the index format inconsistency ckeck is started.

I-1420 Post-operational check cannot be started because printer is still processing another job.

Printing was in progress when starting the post-operational check. —

I-1421 Printer processor is busy.Please wait a moment, and then perform "Post-operational check“.

NG received from the printer during the post-operational check. —

W-1422 Connection with printer failed. No response from the printer during the post-operational check. 1. 1394(interface cable)

malfunction, disconnection or connection error of grounding wire.

2. 1394 CB failure

1. Connect the cable correctly, or replace the cable.

2. Replace the 1394 CB.

E-1425 Printer initialization failed. Call technical representative.Press [Shutdown] to shutdown the system.Press [S-alone] to perform FMP Controller stand-alone operation at next start-up.

Initializing of printer failed at the system start-up. 1. 1394(interface cable)

malfunction, disconnection or connection error of grounding wire.

2. 1394 CB failure 3. System software failure

1. Connect the cable correctly, or replace the cable.

2. Replace the 1394 CB. 3. Restart the system software. If

problems persist, reinstall it.

W-1426 Remote printer operation failed. and perss [Retry].

The printer's remote power ON failed at system start-up.

204

Page 205: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

W-1427 Connection with printer failed. After connection is established, click [Retry].

Error returned when the printer status registering command was issued at the system start-up. 1. 1394(interface cable)

malfunction, disconnection or connection error of grounding wire.

2. System software failure

1. Connect the cable correctly, or replace the cable.

2. Restart the system software. If problems persist, reinstall it.

W-1428 Connection with printer failed. Confirm connection with printer, click [Retry].

Error returned when magazine reading command was issued at the system start-up. 1. 1394(interface cable)

malfunction, disconnection or connection error of grounding wire.

2. System software failure

1. Connect the cable correctly, or replace the cable.

2. Restart the system software. If problems persist, reinstall it.

W-1441 Software error occurred. Restart the FMPC and printer.

NG returned when reading the parameter set from the resource manager. 1. System software failure

2. PC failure

1. Restart the system software. If problems persist, reinstall it.

2. Replace the PC.

W-1442 Software error occurred. Restart the FMPC and printer.

Error returned when JOB list was started. 1. System software failure

2. PC failure

1. Restart the system software. If problems persist, reinstall it.

2. Replace the PC.

E-1443 Communication error occurred while sending images from FMPC to printer. Inspect it referring to manual.

Error occurred when the images were transferred from FMPC to printer. 1. 1394(interface cable)

malfunction, disconnection or connection error of grounding wire.

2. 1394 CB failure 3. System software failure

4. PC failure

1. Connect the cable correctly, or replace the cable.

2. Replace the 1394 CB. 3. Restart the system software. If

problems persist, reinstall it. 4. Replace the PC.

W-1448 Back printer not installed. Install back printer properly.

Back printer not installed. 1. Installing of back printer failed. 2. Connection error or harness

disconnection between the back printer sensor and PDC CB connector.

3. Back printer sensor failure. 4. PDC CB failure 5. CTL CB failure

1. Install the back printer correctly. 2. Connect the cable correctly, or

replace the cable.

3. Replace the sensor. 4. Replace the PDC CB. 5. Replace the CTL CB.

W-1452 Printer cannot start printing because of %PRINTER_STATUS%.

Clear the problem and resume printing.

A printer on-line error occurred during the consistency check.

X-1454 Internal error. Restart scanner and printer. A JOB bag level error has occurred.

No Message Factor Actions

205

Page 206: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

E-1472 A communication error occurred between FMPC and printer. Call technical representative.

Command sending error between FMPC and printer. 1. 1394(interface cable)

malfunction, disconnection or connection error of grounding wire.

2. 1394 CB failure 3. System software failure

1. Connect thr cable correctly, or replace the cable.

2. Replace the 1394 CB. 3. Restart the system software. If

problems persist, reinstall it.

W-1461 Reading digital image file failed. Digital image print cancelled.

Couldn't read the file print image from Imaging Controller.

1. Check the image file and its file format.

2. Restart the Imaging Controller.

W-1462 Digital image processing error. Printing digital image cancelled. File format incorrect.

File format error in DI Controller. 1. Restart the Imaging Controller. 2. Replace the Imaging

Controller's hard disk.

I-1463 Digital image read cancelled due to error occurrence.

Some images may not be printed.Check print results.An error occurred while performing “File to print”.

W-1464 Printer not in stand-by. Current printing order cancelled.

Printing command was issued while the printer was not in STANDBY.

E-1481 Hard disk failure occurred during the data copy. Copying data cancelled.

Consult technical representative.—

E-1482 Hard disk failure occurred. Consult technical representative.

Hard disk failure is detected during the file I/O.

W-1484 Initializing of printer failed.Press [S-alone] to perform FMP Controller stand-alone operation at next start-up.

Initializing of printer failed at the system start-up. 1. 1394 cable connection error

2. Connection error in CTP CB connector

3. CTP CB failure

1. Connect the 1394 cable correctly.

2. Connect the connector correctly.

3. Replace CTP CB.

W-1495 Auto is currently selected. Match the paper types of the upper and lower magazines. Press [Output] to output forcibly.

When switching the magazine, mismatch in paper type (surface or emulsion type) of upper and lower magazines occurred.

1. Match the paper types in upper and lower magazines.

I-1501 Selected function cannot be used. Unsupported function was selected.

I-1502 Insert FD. FD insertion prompted at time of data backup.

W-1503 FD not inserted. FD was not inserted during FD reading. 1. FD is not inserted. 2. FD drive failure

1. Set the FD. 2. Replace the FDD.

I-1504 Insert next FD. When writing to multiple FDs at time of data backup, this message prompts you to insert the next FD.

W-1505 Wrong FD inserted. Insert correct FD.

Incorrect FD is inserted. 1. FD is corrupted. 2. FD drive failure

1. Set the correct FD. 2. Replace the FDD.

No Message Factor Actions

206

Page 207: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

E-1506 Reading of control information file failed. Selected image cannot be displayed.

Files required to read the images couldn't be read. 1. System software failure

2. PC failure

1. Restart the system software. If problems persist, reinstall it.

2. Replace the PC.

I-1507 Data backup completed abnormally.

Data backup failure.—

I-1508 Cancel data backup. Data backup was cancelled by the command issued by operator.

W-1509 Not enough free space on hard disk. Unnecessary files have been deleted.

At the system start-up, specified HD free space for application was not reserved.

1. If there are unnecessary files in D drive, delete them.

W-1510 Date value exceeds the limit. (1998/01/01 00:00:00 - 2100/12/31 23:59:59)

Date values exceeds the limit. 1. Incorrect date entry 2. System software failure

3. PC failure

1. Enter the correct date/time. 2. Restart the system software. If

problems persist, reinstall it. 3. Replace the PC.

W-1511 Next timer-ON time exceeds the limit. (1998/01/01 00:00:00 - 2100/12/31 23:59:59) Confirm the present time.

Next start-up time exceeds the limit. 1. Incorrect date entry 2. System software failure

3. PC failure

1. Enter the correct date/time. 2. Restart the system software. If

problems persist, reinstall it. 3. Replace the PC.

W-1512 Insufficient FD free space. Insert correct FD.

FD has not enough free space.1. FD full 2. FDD failure

1. Insert the new FD. 2. Replace the FDD.

W-1521 PU800B is not turned ON or is disconnected.Check the connection with PU800B.Press [Retry] to retry or [Cancel] to cancel.

Retry it and if this error persists, consult your technical representative.

W-1522 PU800B is not turned ON or is disconnected.Check the connection with PU800B.Press [Retry] to retry or [Cancel] to cancel.

Retry it and if this error persists, consult your technical representative.

W-1523 Pricing unit is not turned ON or is disconnected.Check the connection with PU800B. Press [Retry] to retry.To cancel printing invoice, press [Cancel]. To stop it, press [Stop].

Retry it and if this error persists, consult your technical representative.

W-1524 Backup data for PU800B cannot be read.

—Consult your technical representative.

W-1525 Backup data for PU800B cannot be written.

—Consult your technical representative.

I-1526 Production information log file not found. Create a new file.

Production information log file reading error

W-1527 Production information cannot be written into file.

Production information log file writing error. 1. System software failure

2. PC failure

1. Restart the system software. If problems persist, reinstall it.

2. Replace the PC.

No Message Factor Actions

207

Page 208: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

E-1530 FDi device registration failed. Consult technical representative.

Error in registering the FDiA logical output device. 1. Imaging Controller software

failure.1. Restart the system software. If

problems persist, reinstall it.

W-1531 Device registration to FDi failed. Check network connections. To retry the registration, press [Retry].

Error in registering the FDiA logical output device. 1. Imaging Controller is turned

OFF. 2. LAN cable connection error

3. Imaging Controller software failure.

1. Start up the Imaging Controller. 2. Connect the LAN cable

correctly. 3. Restart the system software. If

problems persist, reinstall it.

W-1534 Order not unlocked. Check the network connections.

Communication error from Imaging Controller occurred during the order processing in FRONTIER. 1. LAN cable connection error

2. Imaging Controller software failure.

1. Connect the LAN cable correctly.

2. Restart the system software. If problems persist, reinstall it.

W-1535 Cannot be serviced. Check the network connections.

Communication error from DI Controller occurred during the order processing in FRONTIER. 1. LAN cable connection error

2. Imaging Controller software failure.

1. Connect the LAN cable correctly.

2. Restart the system software. If problems persist, reinstall it.

E-1536 Cannot be serviced. Consult technical representative.

Incorrect status or no device permission. 1. Imaging Controller software

failure.1. Restart the system software. If

problems persist, reinstall it.

E-1537 Cannot be serviced. Consult technical representative.

Other errors in FDiA 1. Imaging Controller software

failure.1. Restart the system software. If

problems persist, reinstall it.

E-1539 Cannot be serviced. Consult technical representative.

An order is in “waiting” status. 1. Imaging Controller software

failure.1. Restart the system software. If

problems persist, reinstall it.

W-1541 Print service not performed. Check the network connections.

Communication error from DI Controller occurred during the order processing in FRONTIER. 1. LAN cable connection error

2. Imaging Controller software failure.

1. Connect the LAN cable correctly.

2. Restart the system software. If problems persist, reinstall it.

W-1542 Print service not performed. Check the network connections.

Error occurred when the status was changed during the normal printing. 1. LAN cable connection error

2. Imaging Controller software failure.

1. Connect the LAN cable correctly.

2. Restart the system software. If problems persist, reinstall it.

W-1543 Print service not performed. Check the network connections.

Error occurred when the status was changed during the normal printing. 1. LAN cable connection error

2. Imaging Controller software failure.

1. Connect the LAN cable correctly.

2. Restart the system software. If problems persist, reinstall it

No Message Factor Actions

208

Page 209: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

W-1544 Print service not performed. Check the network connections.

Error occurred when order completion is noticed. 1. LAN cable connection error

2. Imaging Controller software failure.

1. Connect the LAN cable correctly.

2. Restart the system software. If problems persist, reinstall it.

W-1545 Print service not performed. Check the network connections.

Error occurred during order deletion. 1. LAN cable connection error

2. Imaging Controller software failure.

1. Connect the LAN cable correctly.

2. Restart the system software. If problems persist, reinstall it.

W-1546 Print service not performed. Check the network connections.

Error occurred when the status is changed while no order is registered. 1. LAN cable connection error

2. Imaging Controller software failure.

1. Connect the LAN cable correctly.

2. Restart the system software. If problems persist, reinstall it.

W-1547 Print service not performed. Check the network connections.

Error occurred during order reading process. 1. LAN cable connection error

2. Imaging Controller software failure.

1. Connect the LAN cable correctly.

2. Restart the system software. If problems persist, reinstall it.

W-1548 The printer is not in STAND-BY. Press [Resume] to try again.

Printer STANDBY notice error.

1. Printer is not in STANDBY. 1. Turn the printer to STANDBY.

E-1549 Cannot be serviced. Consult technical representative.

Order that was not being processed was deleted. 1.Imaging Controller software

failure.1. Restart the system software. If

problems persist, reinstall it.

I-1594 Reading service name list. Wait. Image export/import service name reading message.

E-1596 Service info cannot be read. Check the network connections.

FDI error occurred during reading the service name. 1. LAN cable connection error

2. Imaging Controller software failure.

1. Connect the LAN cable correctly.

2. Restart the system software. If problems persist, reinstall it.

W-1620 Uncompleted orders remain.They will be printed next time at the time of starting. —

If the [OK] button is pressed, the post-operational process will be started. To continue printing, press the [Cancel] button to proceed [Main Menu] - [2 Print].

W-1621 As for the next piece of print, the width of paper is mismatched to the magazine.(???mm)Press [Order] to output forcibly per Order. Press [Image] to output forcibly per Image.When replacing the magazine, press [OK] after the initialization of printer is completed. To stop printing, press [Abort].

Press the [Order] button to output all current images forcibly. Press the [Image] to output forcibly the image currently processed only. It is recommended that you replace the magazine for the correct one, then press the [OK] button after initializing the printer, and then perform printing again. If the [Abort] button is pressed, the printing process will be stopped.

No Message Factor Actions

209

Page 210: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

W-1622 As for the next piece of print, the paper type is mismatched to the magazine.Press [Order] to output forcibly per Order. Press [Image] to output forcibly per Image.When replacing the magazine, press [OK] after the initialization of printer is completed. To stop printing, press [Abort].

Press the [Order] button to output the current images forcibly. Replace the magazine for the correct one, then press the [OK] button after initializing the printer, and then perform printing again. If the [Abort] button is pressed, the printing process will be stopped.

W-1626 As for the next piece of print, the width of paper or the paper type is mismatched to the magazine.(???mm)Press [Order] to output forcibly per Order. Press [Image] to output forcibly per Image.When replacing the magazine, press [OK] after the initialization of printer is completed. To stop printing, press [Abort].

Press the [Order] button to output all current images forcibly. Press the [Image] to output forcibly the image currently processed only. It is recommended that you replace the magazine for the correct one, then press the [OK] button after initializing the printer, and then perform printing again. If the [Abort] button is pressed, the printing process will be stopped.

W-1627 “Auto” is currently selected.Match the paper types of the upper and lower magazines.Press [Output] to output forcibly.

Press the [Abort] button, then select [Upper] or [Lower] in “Switch Magazine”.

W-1662 Work can't be finished because PU800B is while printing is processed.Wait to the printing management end for about %NUM% seconds.

— —

W-1751 Couldn’t send the status information. Check the network connections.

Status information sending error. 1. LAN cable connection error

2. DI Controller software failure.

1. Connect the LAN cable correctly.

2. Restart the system software. If problems persist, reinstall it.

W-1902 Cannot print because the printer memory is full. Retry printing when enough memory is reserved.

Enough memory cannot be reserved in operation SS because too many printing (scanning) requests are issued.

W-1903 Cannot output because the image data occupy large amounts of memory. Wait until enough memory is reserved and retry.

Enough memory cannot be reserved in operation SS because too many outputting requests are issued.

W-1930 %MAGAZINE% not installed or paper end processing in progress. After the door LED in the magazine section turns green, install magazine and restart printing.

The magazine is not installed.

W-1931 %MAGAZINE% not installed or paper end processing in progress. After the door LED in the magazine section turns green, install magazine and restart printing.

A magazine not found when the index format inconsistency check is started. —

W-1932 Print size and magazine paper width mismatched, or change print size. Press [Output] to output forcibly.

The print size and the paper width of the selected magazine mismatched.

No Message Factor Actions

210

Page 211: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

W-1938 Print size exceeds the limit. Change print size.

The selected print size (in feed direction) exceeds the value available in 10GD.

I-1939 The post-operational check cannot be started because printing is in progress or the printed paper remains in the printer.

A post-operational check was started while the printer was in use.

W-8101 Communication with Frontier Manager failed.The orders with the installed papers will be printed preferentially.To use scheduling function, return to Main Menu and check connection, then resume printing.

Wait for a moment with no operation, so this message will disappears, then other print-waiting orders with the setting of paper that matches the currently installed paper will be printed automatically, while skipping the order with the mismatched paper setting.To replace the magazine with the correct one, click the [OK] button. Unless the orders with mismatched paper are urgent ones, it is recommended to print the possible orders first, then the remaining orders after replacing the magazine.

W-8102 Paper (width and paper type) and magazines are mismatched to the next order.Exchange the magazine after the display to be able to exchange the magazine afterwards appears.Press [Output] output forcibly.

To replace the magazine with the correct one, click the [OK] button. To output the current orders forcibly, press the [Output] button.

No Message Factor Actions

211

Page 212: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

8 Measures against FMPC Failures

To return to the direct-connecting type in FRONTIER 350/370, use the following procedures. (IEEE1394 board

also functions as repeater.)

Make sure that the FMPC is turned ON, and that at least one IEEE1394 board is normally operated.

1 On the “Main Menu” screen in the scanner (SP), select [4 Setup and Maintenance], then click the [OK] button.

If the "initializing of printer failed" message appears,

click the [Retry] button to clear it, and then perform

the procedures.

2 In the “Login” dialog, select [SE2] as user name and enter the password “7777”, and then click the [OK] button.

3 Select [41 System Operation Setup and Check] - [41F Installation Information Setup], then click the [Start] button.

4 The “[41F] Installation Information Setup” screen appears.

8.1 To Return to Direct-connecting Type in FRONTIER 350/370

212

Page 213: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

5 Set to [ON] for [Printer].

6 On the “Main Menu” screen in the scanner (SP), select [3 Post-operational Check], then click the [OK] button, then shut down the scanner.

7 Switch the display to the FMPC by pressing the button in the switcher.

The display can be switched also by pressing the [Ctrl] key twice swiftly.

8 On the “Main Menu” screen in the FMPC, select [3 Post-operational Check], then click the [OK] button, then shut down the FMPC and printer (LP).

9 Connect the IEEE1394 cable from printer and the one from scanner to the connectors on the same board in the FMPC.

10 Insert the FD without the system program into the FD drive of the FMPC, and then turn it ON.

Make sure that the FD does not contain the executable file.

• After start-up, the error message “Non-System

disk or disk error” appears, and the “Windows”

is not started up.

MP019

IEEE1394 from printer (LP)

IEEE1394 from scanner (SP)

MP011

213

Page 214: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

11 Turn on the printer, then set the switch to STANDBY.

In this case, the printer (LP) cannot be started up remotely by turning on the scanner (SP).

12 Turn on the scanner (SP).

13 After the restart, the “Main Menu” screen appears.

IMPORTANTTo perform printing from the Imaging Controller, set up the FMPC logical device name on the administration screen in each DI application on the Imaging Controller.

EZ1192

214

Page 215: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

To return to the direct-connecting type in FRONTIER 355/375, use the following procedures. (IEEE1394 board

also functions as repeater.)

1 On the “Main Menu” screen in the scanner (SP), click the [Setup and Maintenance] button.

If the “Setup and Maintenance” screen does not appear, start up the FRONTIER in the stand-alone mode.

2 Enter the password “7777”, and then click the [OK] button.

3 Select [01 System Operation Setup and Check] - [0140 Installation Information Setup].

4 The [0140 Installation Information Setup] screen appears.

5 Set to [ON] for [Printer].

6 On the “Main Menu” screen in the scanner (SP), click the [Post-operational Check] button, then shut down the scanner.

8.2 To Return to Direct-connecting Type in FRONTIER 355/375

215

Page 216: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

7 Switch the display to the FMPC by pressing the button in the switcher.

The display can be switched also by pressing the [Ctrl] key twice swiftly.

8 On the “Main Menu” screen in the FMPC, select [3 Post-operational Check], then click the [OK] button, then shut down the FMPC and printer (LP).

9 Disconnect the IEEE1394 cable from the scanner (SP).

10 Connect the IEEE1394 cable prom printer (LP) to the scanner (SP).

11 Turn on the printer (LP).

In this case, the printer(LP) cannot be started up remotely by turning on the scanner (SP).

12 Turn on the scanner (SP).

MP019

MP047

MP048

ZII040

216

Page 217: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

13 After the restart, the “Main Menu” screen appears.

IMPORTANTTo perform printing from the Imaging Controller, set up the FMPC logical device name on the administration screen in each DI application on the Imaging Controller.

217

Page 218: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

9 Index

A[A1] Stand-alone Upgrade in SP [Ver.1.5 ->

Ver.1.7] and DI Print/Data Writing Software

[C4/C5] Client Installation in SP......................87

[A1] Stand-alone Version-up and DI Print/Data

Writing Software Installation in SP...................61

Accumulated Production Information

(413) ......................................................... 105, 154

Auto Cleaning Output Measurement/Setting

(462) ...................................................................192

Auto-cleaning Pump Output Measurement .........138

BB Laser (B-LD) Data (45F) .....................................178

B Laser (B-SHG) Data (45F) .................................128

Back Print Setup (42O)...........................................117

Back Printer Test (45N) ..........................................134

Back Printing Setup (42O) .....................................164

Bios Setup ..................................................................16

CChanging Mode from SP-3000 to FMPC...............31

Checking the Kit Contents........................................11

Clear Error Log (41E)..................................... 109, 158

COM Port Setting (47A)..........................................200

Command (48C) ......................................................149

Command (49C) ......................................................202

Connecting FMPC, FRONTIER, LAN Cable

and Monitor Switcher ............................ 31, 56, 81

Control Strip Processing.........................................113

Copying Print Size Table from SP to FD ...............30

Copying Print Size Table to FD then Copying

LP1500/2000 Print Size Table to FMPC.........98

Copying Print Size Table to FD then Copying

SP-3000 Print Size Table to FMPC.................71

Copying SP-3000 Print Size Table to FMPC ........40

Creating Backup FD for FMPC, SP1500/2000

and LP1500/2000 .............................................100

Creating Backup FD for FMPC, SP-3000

and LP1500/2000 ...............................................74

Creating Backup FD for FMPC/SP-3000...............50

Creating Backup FD for SP1500/2000,

LP1500/2000.......................................................79

Creating Backup FD for SP-3000 and

LP1500/2000.......................................................54

Creating Backup FD for SP-3000 and LP5700.....30

DData Backup (417) ......................................... 108, 157

Data Download (45U) .................................... 135, 184

Data Saving (45T) .......................................... 135, 183

DI Manager Administrative Setting (41I)..... 110, 159

DI Print/Data Writing Software [C4/C5] Client

Installation in FMPC...........................................69

Disabling Network Connection on

SP Side ................................................... 38, 60, 86

Disabling of “Rack Auto Cleaning”................... 53, 78

EEnabling of “Rack Auto Cleaning”.................... 73, 99

Error Indication Rule ...............................................203

Error Information Check (415)...................... 107, 156

Error Messages and Countermeasures...............203

Ethernet Cable ...........................................................10

Evaporation Correction Rate Setting (465) .........142

Explorer (48B) ..........................................................148

Explorer (49B) ..........................................................201

Extension Cable for Keyboard.................................10

FFeeding Position Sensor Fine Adjustment

(45b) ...................................................................185

Filter Replacement History (45a) ..........................184

FMPC [D20] Installation (Reinstall) with

Printer’s Backup FD ...........................................66

FMPC [D20] Software Installation (Reinstall)

with Printer's Backup FD ...................................92

FMPC Output Device Setting in Imaging

Controller ................................................ 44, 72, 99

GG Laser (G-SHG) Data (45E) ....................... 128, 177

G Laser (SHG) Optimal Temperature

Setup (454)........................................................171

G, B Laser (SHG) Optimal Temperature

Setup (454)........................................................122

HHow to Read This Manual..........................................9

218

Page 219: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

IIEEE1394 Board Installation....................................15

IEEE1394 Driver Installation in SP .........................60

IEEE1394 Driver Pre-installation ............... 29, 63, 89

Image Position and Tilt Fine Adjustment (458)...173

Image Position Fine Adjustment (458) .................124

Image Position Initial Setting (45c) .......................186

Input/Output Device Setup for FMPC.....................41

Installation for FRONTIER 350/370........................76

Installation for FRONTIER 355/375........................51

Installation for FRONTIER 570................................14

Installation Information Confirmation (416) .........108

Installation Information Reference (416)..............157

Installation Information Setup (41F) ............ 110, 159

Installation Information Setup for FMPC......... 70, 96

Installation Information Setup in FMPC .................43

Installation Procedure List........................... 14, 51, 76

Installing DI Print/Data Writing Software

[C4/C5] Client in FMPC .....................................40

Installing FMPC Software [D20] ..............................39

Installing IEEE1394 Driver for LP in FMPC.... 65, 91

Installing IEEE1394 Driver for SP in FMPC ... 64, 90

Installing Other Driver Software ..............................21

Installing SP-3000 Driver..........................................37

LLaser Beam Sync. Fine Adjustment Print

(45J)........................................................... 131, 180

Laser Exposure Check (45C) ....................... 127, 176

Laser History Display (45K) .......................... 132, 181

Low Volume Processing Setup (466) ...................195

Low Volume Setting (466)......................................142

MMain Scan/Laser Beam Sync. Rough

Adjustment (45H)..............................................179

Main Scanning Position Adjustment/Laser

Beam Sync. Rough Adjustment (45H) ..........129

Maintenance Menu

(FRONTIER 350/370/355/375).......................102

Maintenance Menu (FRONTIER 570)..................150

Measures against FMPC Failures.........................212

Message Icons.........................................................203

Message Number ....................................................203

Messages..................................................................204

NNetBEUI Setup...........................................................28

OOperational Check...................................... 45, 75, 101

Operational Procedure................................... 102, 150

Option Adjustment / Maintenance (7)...................200

Output Device Setup for SP and

Restarting SP ............................................... 70, 97

PPaint (48A)................................................................148

Paint (49A)................................................................201

Paper Condition Method Setup (42J).......... 117, 163

Paper Condition Setup.........................43, 73, 99, 111

Paper Condition Setup (421) .................................160

Paper Condition Setup Table (LUT) Copy

(45L) .......................................................... 132, 182

Paper Feed (455) ........................................... 123, 172

Paper Feed Length Adjustment (452) ..................120

Paper Magazine Feeding Fine Adjustment

(452) ...................................................................168

Paper Magazine Registration (451)............. 118, 166

Paper Surfaces Display Setup (42R) ...................165

PC Preparations ........................................... 15, 53, 78

Power Souce Specification ......................................13

Precut Length Setting (45V) ..................................136

Preparations ...............................................................10

Print Condition Setup and Check (2)....................160

Print Condition Setup and Check (42)..................111

Print Size Setup (424).................................... 116, 162

Printer Adjustment/Maintenance (45)...................118

Printer Adjustment/Maintenance (5) .....................166

Printer Function Select (45B) ....................... 126, 175

Printer Input Check (457) .............................. 124, 173

Printer I/O Check (45A) ................................. 125, 174

Printer Mechanical Fine Adjustment (45M) .........182

Printer Mechanism Fine Adjustment (45M).........133

Printer Operation Data Display (45P).......... 134, 183

Printer Temperature Display (456) .............. 123, 172

Processing Solution Temperature Check ............113

Processing Temperature Setting (463) ....... 141, 194

Processor Adjustment/Maintenance (46) ............137

Processor Adjustment/Maintenance (6)...............190

Processor Input Check (468)........................ 144, 197

219

Page 220: Fuji FRONTIER 350 370 SERVICE MANUAL

distributed by www.minilablaser.com

Processor I/O Check (46A) ........................... 145, 197

Processor Operating Condition Setup

(46B) .......................................................... 146, 198

Processor Operation Data Display 2 (46E) .........147

Processor Operation Data Display (46C) ... 146, 199

Processor Temperature Calibration (467) .. 143, 195

Production Information 1 (411)..................... 103, 151

Production Information 2 (412)..................... 104, 152

PS Liquid Concentration Management (46G).....199

RR Laser (R-LD) Data (45D) ........................... 127, 177

Recommended Monitor Switcher............................10

Recommended PC ....................................................10

Replacing the ROM for Printer ......................... 55, 80

Replenisher Pump Output Measurement ............137

Replenisher Pump Output Measurement/Setting

(461) ...................................................................190

Replenisher Rate Setup (464) ...............................141

Required Tools and CDs ..........................................13

SScanning Position/Scanning Home Position

Parameter Setup (45G) ...................................129

Scan/Scan Home Position Parameter (45G) ......178

Sensor Calibration (Daily) (45g)............................189

Sensor Calibration (Initial) (45f).............................188

Setup of Remaining Space in Hard Disk ...............18

SP-3000 Monitor's Power Cable .............................10

Special Operations (48)..........................................148

Special Operations (9) ............................................201

Starting-up LP in ROM Mode and Checking

ROM Version (2.0-0x-000)......................... 65, 90

Sub-scan Feeding Speed Adjustment (45d) .......187

Sub-scanning Soft Nip Fine Adjustment (45e)....187

System Operation Setup and Check (1) ..............151

System Operation Setup and Check (41)............103

System Shutdown....................................... 50, 75, 101

TTest Pattern Printing (453)............................ 121, 169

Timer Setup (414)........................................... 106, 155

Timer Setup in FMPC ...............................................42

To Return to Direct-connecting Type in

FRONTIER 350/370.........................................212

To Return to Direct-connecting Type in

FRONTIER 355/375.........................................215

Turning on FMPC ............................................... 60, 85

Turning on FMPC and Installing LP5700

Driver ....................................................................36

Turning on Imaging Controller .................................41

Turning on LP5700....................................................35

UUser Registration.......................................................21

WWindows Settings ......................................................22

Windows XP Installation and Partitioning ..............16

XX-#### Actions.........................................................203

220

Page 221: Fuji FRONTIER 350 370 SERVICE MANUAL

Questionnaire concerning This ManualFujifilm’s Technical Division Photo Products Marketing would be most grateful if you would make copies of thisform, then complete and send them to us by FAX.Your opinions will contribute greatly to an accurate assessment of the overall quality of each manual.All questions can be answered by ticking [✓] the appropriate box(es), but in addition to these answers, pleaseprovide us with your written comments in the lined spaces following each block of questions.

Manual Title and Reference Number

Title :

Reference Number :

Your Name and Company

Name :

Company :

Your E-mail Address and FAX Number

E-mail Address :

FAX Number :

Question 1 • How would you rate this manual overall?

(1) Very easy to use and understand (2) Fairly easy to use and understand

(3) Slightly difficult to use and understand

(4) Very difficult to use and understand

• Please provide us with your reasons and comments.

Question 2 • Have you found any technical errors, errors in spelling, or missing words in this manual?

Yes No

• If you have ticked (Yes), please let us know what these errors and missing words are.

Question 3 • How would you rate the writing (language, choice of words/phrases, etc.) and the illustrations/

diagrams, etc.?

(1) Clear and easy to follow (2) Should be simplified

(3) Difficult to follow

(1)’ [Illustrations, etc.] Of adequate size

(2)’ [Illustrations, etc.] Too small

(3)’ [Illustrations, etc.] Difficult to follow

• If you have ticked (2), (3) or (3)’, please give us your reasons.

Additional Comments/Requests

concerning This Manual

FAX : 81-3-5484-0454

Please return this questionnaire to : FAX No. : Tokyo 81-3-5484-0454

FRONTIER 350/370 355/375/570Frontier Manager Printer Controller Ver.2.0INSTALLATION/SERVICE MANUAL/PARTS LIST

PP3-A1060E

distributed by www.minilablaser.com

Page 222: Fuji FRONTIER 350 370 SERVICE MANUAL

FUJI PHOTO FILM CO., LTD.

26-30, Nishiazabu 2-chome, Minato-ku, Tokyo 106-8620, Japan.

Printed on Recycled Paper

Ref.No.PP3-A1060E ESD-05.01-FG Printed in Japan

distributed by www.minilablaser.com