FUEL SERVICING-AUTOMATIC MODE · 2009. 8. 7. · FUEL SERVICING-AUTOMATIC MODE Connect static ground wires. Connect fuel hoses. Open fuel hose nozzle valves at fuel control station

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

  • FUEL SERVICING-AUTOMATIC MODE

    Connect static ground wires. Connect fuel hoses. Open fuel hose nozzle valves at fuel control station.. Test quantity and high level systems. Select desired total fuel load on pre-selector. Ensure that refuel/defuel valve selectors are at normal guarded position. . Center tank control handle to "ON".. Fuel control selector to refuel. . Activate deadman control.. Monitor fuel gages.

    All tanks are filled simultaneously. The valves will close automatically as the desired quantity is reached.

    . Release deadman control.

    . Fuel control selector to "OFF".

    . Center tank control handle to "OFF". . Secure panel door.

    Close nozzle valves, disconnect hoses, install adapter caps. Disconnect static ground wires.

  • FUEL SERVICING-MANUAL MODE

    Connect static ground wires. Connect fuel hoses. Open fuel hose nozzle valves at fuel control station.

    . Test quantity and high level systems

    . Lift guard on refuel/defuel valve selectors and place in open position . Center tank control handle to "ON".. Fuel control selector to refuel.. Activate deadman control.. Monitor fuel gages and place valve switches to "SHUT" as desired quantity in each tank is reached. . Release deadman control.. Fuel control selector to "OFF".. Center tank control handle to "OFF". . Secure panel door.

    Close nozzle valves, disconnect hoses, install adapter caps. Disconnect static ground wires.

    DEFUELING

    - Connect static ground wires, connect fuel hoses, open fuel hose nozzle valves.- At fuel control panel:

    . Test quantity and high level systems

    . Place refuel/defuel valve selectors in "OPEN" position . Center tank control handle to "ON". Fuel control selector to defuel

    - Apply defuel suction, transfer valve handle to open- Boost pumps-On (optional) increases defuel rate (this is preferred method)- Monitor fuel gages, close valve switches when desired fuel level is reached in each tank.