FS1 FS5

Page 2: FS1 FS5 - Firestopping - Passive Fire Protection - Cable ... · 5. The area and insulation value is effectively rebuilt 3. FS5 coating is applied by brush 4. A fibre mesh is used

FS1 is an intumescent coating system that will expand 100 times its thickness under a fire.

In a fire situation, our systems will prevent: Ignition of the cable insulation.

Release of toxic fumes from the cable insulation.Release of poisonous gas (HCL) from the cable insulation

The cable tray from melting and collapsing.

Our coating has been tested in a hydrocarbon fire for 60 minutes

Page 3: FS1 FS5 - Firestopping - Passive Fire Protection - Cable ... · 5. The area and insulation value is effectively rebuilt 3. FS5 coating is applied by brush 4. A fibre mesh is used

Uncoated cables experience a short circuit after less than 2 minutes in an oil fire while cables coated with Fire Security coating will

function up to 1 hour without a short circuit.

Our coating has been tested in a hydrocarbon fire for 60 minutes

The yellow curve shows the temperature of an ISO fire which is a normal fire in a building.

The red curve shows the temperature of an oil fire, which is the temperature Fire Security has tested their coatings. This is the temperature you will be facing if you had such a fire.

Page 4: FS1 FS5 - Firestopping - Passive Fire Protection - Cable ... · 5. The area and insulation value is effectively rebuilt 3. FS5 coating is applied by brush 4. A fibre mesh is used

Upgrading of existing cables in order to provide fire resistant properties in accordance with the IEC-Publication 331.

FS1 is an Intumescent coating system.The system is Water based, Non toxic, Highly elastic and has

an Excellent adhesion.

”We have used Fire Security’s well documented coating systems in our melt-ing plant for the last 20 years.During these years we have experienced that a fire was effectively stopped thanks to the fact that the cables were protected with the coating system from Fire Security.”

DNV FS1

Page 5: FS1 FS5 - Firestopping - Passive Fire Protection - Cable ... · 5. The area and insulation value is effectively rebuilt 3. FS5 coating is applied by brush 4. A fibre mesh is used

FS1 is an Intumescent coating system.The system is Water based, Non toxic, Highly elastic and has

an Excellent adhesion.

DNV FS1

Page 6: FS1 FS5 - Firestopping - Passive Fire Protection - Cable ... · 5. The area and insulation value is effectively rebuilt 3. FS5 coating is applied by brush 4. A fibre mesh is used

FS5 is an ablative coating system, which in addition to be fire resistant is weather resistant, resistant to UV, ozone, oil, mud and chemicals.

This system is water based, non toxic, highly elastic and has an excellent adhesion.

Statement Petrobras

Page 7: FS1 FS5 - Firestopping - Passive Fire Protection - Cable ... · 5. The area and insulation value is effectively rebuilt 3. FS5 coating is applied by brush 4. A fibre mesh is used

Fire Security is a company specializing in repair and protection of electrical cables, offering our systems with specially trained personnel for application world-wide. We do on-site survey & inspection, followed by a written report, and an offer.

FS5 is an ablative coating system, which in addition to be fire resistant is weather resistant, resistant to UV, ozone, oil, mud and chemicals.

This system is water based, non toxic, highly elastic and has an excellent adhesion.

Page 8: FS1 FS5 - Firestopping - Passive Fire Protection - Cable ... · 5. The area and insulation value is effectively rebuilt 3. FS5 coating is applied by brush 4. A fibre mesh is used

Typical picture of outer sheath damaged cables caused by UV and ozone.

Typical picture of outer sheath damaged cables caused by vibration and vessels movement.

Typical Damaged Cables

Typical picture of outer sheath damaged cables caused by oil, mud and chemicals.

This repair can be done under normal operation and no shutdown is required.

Page 9: FS1 FS5 - Firestopping - Passive Fire Protection - Cable ... · 5. The area and insulation value is effectively rebuilt 3. FS5 coating is applied by brush 4. A fibre mesh is used

7. The affected cable is tied in place and sprayed with FS5 together with the rest of the cables on the cable tray.

Typical picture of outer sheath damaged cables caused by UV and ozone.

Typical picture of outer sheath damaged cables caused by vibration and vessels movement.

Typical Damaged Cables

Typical picture of outer sheath damaged cables caused by oil, mud and chemicals.

This repair can be done under normal operation and no shutdown is required.

6. FS5 coating is applied to smooth finish the repair

5. The area and insulation value is effectively rebuilt

3. FS5 coating is applied by brush 4. A fibre mesh is used to rebuild theinsulation cross sectional area and to gain

mechanical strength

1. The damaged outer sheath of the cable is removed

2. A metal shielding tape is used to effectively rebuild the cross sectional area

of the damaged shield

Repairing Cables With FS5 Fiber

Page 10: FS1 FS5 - Firestopping - Passive Fire Protection - Cable ... · 5. The area and insulation value is effectively rebuilt 3. FS5 coating is applied by brush 4. A fibre mesh is used

Statement Total DNV FS5

Page 11: FS1 FS5 - Firestopping - Passive Fire Protection - Cable ... · 5. The area and insulation value is effectively rebuilt 3. FS5 coating is applied by brush 4. A fibre mesh is used

DNV FS5

Page 12: FS1 FS5 - Firestopping - Passive Fire Protection - Cable ... · 5. The area and insulation value is effectively rebuilt 3. FS5 coating is applied by brush 4. A fibre mesh is used

Our products have been tested and approved by the worlds leading international

classification societies and authorities.