6
1 Code Approvals: 1 ≥90% required to be considered closed cell *Froth-Pak™ Insulation, US offering only 1 Tack Free/Cure Time: Tack Free/Cure Time: Shelf life: Shelf life: Kit Reusability: Kit Reusability: Closed Cell Content: Closed Cell Content: R-Value: R-Value: DuPont™, the DuPont Oval Logo, and all trademarks and service marks denoted with ™, SM or ® are owned by affiliates of DuPont de Nemours See Product Manual for Full Safety and Product Information.

Froth-Pak Old Formulation Insulation Sell Sheet

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Froth-Pak Old Formulation Insulation Sell Sheet

1

Froth-Pak™ Spray FoamsLet's compare

Code Approvals:ICC

ES ESR 3228

ASTM E84 Class A*

NFPA 286

UL R7813

GreenCircle®

Energy Star

Code Approvals:ICC

ES ESR 3228

ASTM E84 Class A*

NFPA 286

UL R7813

GreenCircle®

Energy Star

While you may know and trust our legacy Froth-Pak™ formulation, we want you to know that the NEW Froth-Pak™

formulation boasts a GWP reduction of over 99% and contains no ozone-depleting chemicals or HFCs. All while

maintaining or improving the performance attributes you have come to expect from the market-leading spray foam brand.

Take a look at the improvements noted below- it’s worth the change! Learn more at froth-pak.com.

Froth-Pak™ New, Low-GWP,

HFC-Free Formulation

Froth-Pak™ Legacy

Formulation

1 ≥ 9 0 % r e q u i r e d t o b e c o n s i d e r e d c l o s e d c e l l* F r o t h - P a k ™ I n s u l a t i o n , U S o f f e r i n g o n l y

1

Tack Free/Cure Time:45-60 Seconds

Tack Free/Cure Time:30 Seconds

Shelf life:15 Months

Shelf life:15 Months

Kit Reusability:Up to 30 days

Kit Reusability:Up to 30 days

Closed Cell Content:90%

Closed Cell Content:Improved to 92%

R-Value:High R-Value of 6.1 (1”) and

12.2 (2”)

R-Value:Maintained High R-Value of

6.1 (1”) and 12.2 (2”)

D u P o n t ™ , t h e D u P o n t O v a l L o g o , a n d a l l t r a d e m a r k s a n d s e r v i c e m a r k s d e n o t e d w i t h ™ , S M o r ® a r e o w n e d b y a f f i l i a t e s o fD u P o n t d e N e m o u r s

S e e P r o d u c t M a n u a l f o r F u l l S a f e t y a n d P r o d u c t I n f o r m a t i o n .

Page 2: Froth-Pak Old Formulation Insulation Sell Sheet

PRODUCT DETA ILS

Froth-Pak™ Spray Foam Insulation is a two-component,

quick-cure polyurethane foam that fills cavities, penetrations,

and cracks greater than 2". Froth-Pak™ Insulation Spray

Foam is a chemically cured foam design to significantly

reduce curing time. It dispenses, expands and becomes

tack-free in seconds.

(LEGACY FORMULATION)

FROTH-PAK™ SPRAY

FOAM INSULATION

W H E R E T O

U S E

FEATURES AND BENEF ITS

Expands quickly to fill larger gaps and penetrations greater than 2""

Provides a high level of insulating R-value on initial application

Reusable for 30 days

Forms a long-lasting, airtight, weather-resistant seal

Seals out moisture, dust and pests

Helps prevents rot, decay and other effects of moisture leakage

Self-contained, portable kit

Multiple dispensing heads provide the perfect coverage

Minimal setup time

Dries completely in less than a minute

Comes in multiple tank sizes, 210 pictured here

Attic

Penetrations

HVAC

Penetrations

Ducting Pipe and

Plumbing

Penetrations

Sill Plate

Electrical

Penetrations

Wall/Attic

Penetrations

Rim Joists

Legacy Formulation

For more information, scan below

for access to our how-to use

videos:

Page 3: Froth-Pak Old Formulation Insulation Sell Sheet

Froth-Pak™ 650Froth-Pak™ 210

650210

Froth-Pak™ 350 (gal)

Froth-Pak™ 17 (gal) Froth-Pak™ 27 (gal) Froth-Pak™ 60 (gal) Froth-Pak™ 120 (gal)

45,820

2,1503,4807,16016,110

PRODUCT EASE OF USE

Chemically cured foam with significantly reduced curing time

Able to skin over in 30–40 seconds and cure in minutes**

Available in refillable cylinders or disposable kits

Useful for commercial applications including spray polyurethane

foam roof repair, sealing roof perimeters and parapet walls

Useful for residential applications including roof and wall junctions;

wall and attic penetrations; electrical, mechanical, and plumbing

penetrations and other gaps, cracks, or crevices in the building

envelope

Froth-Pak™ Foam Insulation is:

AVA ILABLE S IZES

Froth-Pak™ Insulation is typically sold as a complete 43 lb. (Froth-Pak™

210) or 125 lb. (Froth-Pak™ 650) portable kit that includes pressurized

“A” and “B” cylinders, plus dispensing gun/hose assembly and

accessories. Froth-Pak™ Insulation is also available in refillable,

returnable cylinders for commercial applications requiring a large amount

of foam. See Table 1 for yield and size information.

TABLE 1 : S IZES AND THEORET ICAL Y IELDS

P r o d u c t

Kits

Refillable Cylinders

b o a r d f tT h e o r e t i c a l Y i e l d ,( 1 )

( 1 ) T h e t h e o r e t i c a l y i e l d h a s b e c o m e a n i n d u s t r y s t a n d a r d f o r i d e n t i f y i n g c e r t a i n s i z e s o ft w o - c o m p o n e n t k i t s . T h e o r e t i c a l y i e l d c a l c u l a t i o n s a r e p e r f o r m e d i n p e r f e c t l a b o r a t o r yc o n d i t i o n s , w i t h o u t t a k i n g i n t o a c c o u n t t h e l o s s o f b l o w i n g a g e n t o r t h e v a r i a t i o n s i na p p l i c a t i o n m e t h o d s a n d t y p e s .

* * A c t u a l c u r e t i m e w i l l d e p e n d o n t e m p e r a t u r e , f o a m t h i c k n e s s , t h e s p e c i f i c n o z z l e u s e d , e t c* F r o t h - P a k ™ F o a m I n s u l a t i o n i s a f o r m e r p r o d u c t o f T h e D o w C h e m i c a l C o m p a n y .

Legacy Formulation

Page 4: Froth-Pak Old Formulation Insulation Sell Sheet

Thermal Resistance per inch, ASTM C518, ft •h•°F/Btu, R-value, min.

Maximum Service Temperature, °F

Nominal Density, ASTM D1622, lb/ft

InitialAged 180 days at 75°F – 1.0” Aged 180 days at 75°F – 2.0”Air Leakage, ASTM E283 0.012 L/sec-m @ 75Pa ASTM E2178 0.0088 L/sec-m @ 75PaWater Vapor Permeance, ASTM E96 -40 - 0.3 perm @ 1” thick perm @ 2” thickWater Absorption, ASTM D2842, % by volumeDimensional Stability, ASTM D2126, % volume change 100°F/97% RH @ 1wk 158°F/97% RH @ 1wk -40°F/amb RH @ 1wk 158°F/amb RH @ 1wkCompressive Strength, ASTM D1621, lb/in , parallelTensile Strength, ASTM D1623, lb/in , parallel

240

1.75

6.2 6.2 (when sprayed as 1” thickness) 12.2 (6.2/in when sprayed as 2” thickness)

00

6.26.23.2

0.78.30.33.117.229.0

PROPERT IES

Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-866-583-2583 when

additional guidance is required for writing specifications that include this product.

TABLE 2 : TYP ICAL PHYS ICAL PROPERT IES OF FROTH-PAK™ FOAM SEALANT

P r o p e r t y a n d T e s t M e t h o d V a l u e

3

T h e s e p r o p e r t i e s a r e t y p i c a l b u t d o n o t c o n s t i t u t e s p e c i f i c a t i o n s .

T e s t e d a t 2 ” t h i c k n e s s , f u l l c o v e r a g e .T h i s n u m e r i c a l f l a m e s p r e a d r a t i n g i s n o t i n t e n d e d t o r e f l e c t h a z a r d s p r e s e n t e d b y t h i s o r a n y o t h e r m a t e r i a l u n d e ra c t u a l f i r e c o n d i t i o n s . R m e a n s r e s i s t a n c e t o h e a t f l o w . T h e h i g h e r t h e R - v a l u e , t h e g r e a t e r t h e i n s u l a t i n g p o w e r .

T h e s e p r o p e r t i e s a r e t y p i c a l b u t d o n o t c o n s t i t u t e s p e c i f i c a t i o n s

2

2

2

*

12

3

INSTALLAT ION

Complete operating instructions are provided with every

Froth-Pak™ Foam Insulation purchase. Read all

information and cautions before application.

Check with local codes prior to use. If used in an exterior

setting, a coating must be applied for ultraviolet (UV)

protection.

Use ConditionsAvoid overfilling restricted spaces. The reaction of these

chemicals causes expansion and may exert enough force to

cause an uncontrolled stream of foam, spraying the work

area and possibly the operator.

Froth-Pak™ foam will adhere to most surfaces and skin.

Avoid ALL skin contact. Wear gloves and protective clothing.

Re-entry allowed after only one hour post-application.

Cured foam is difficult to remove. Cured foam must be

mechanically removed or allowed to wear off in time.

Curing

Equipment

Dispensing gun/hose assembly and accessories included in kit..

* S e e f u l l v e n t i l a t i o n g u i d e l i n e s a t b u i l d i n g . d u p o n t . c o m .

( 3 )

2

2

Froth-Pak™ may be used as an air barrier material for wall/

floor and roof/wall intersections in the exterior building

envelope when installed at a maximum thickness of 2 inches

by a width of 6 inches (the length is unlimited). Please see

ICC ESR-3228 for a full list of approved applications.

Application

Legacy Formulation

Page 5: Froth-Pak Old Formulation Insulation Sell Sheet

TEST ING

C203 – Standard Test Methods for Breaking Load and

Flexural Properties of Block-Type Thermal Insulation

C273 – Standard Test Method for Shear Properties of

Sandwich Core Materials

C518 – Standard Test Method for Steady-State Thermal

Transmission Properties by Means of the Heat Flow Meter

Apparatus

D1621 – Standard Test Method for Compressive Properties

of Rigid Cellular Plastics

D1622 – Standard Test Method for Apparent Density of

Rigid Cellular Plastics

D1623 – Standard Test Method for Tensile and Tensile

Adhesion Properties of Rigid Cellular Plastics

D2842 – Standard Test Method for Water Absorption of

Rigid Cellular Plastics

E96 – Standard Test Methods for Water Vapor Transmission

of Materials

Applicable Standards – ASTM International E283 – Standard Test Method for Determining Rate of Air

Leakage Through Exterior Windows, Curtain Walls and

Doors Under Specified Pressure Differences Across the

Specimen

E2178 – Standard Test Method for Air Permeance of

Building Materials

Underwriters Laboratories, Inc. (UL) Classified, see

Classification Certificate R7813

National Fire Protection Association – per NFPA 286 testing,

can be left exposed in non-fire-resistant-rated roof/wall

junctures, maximum 6” high and 2” deep (unlimited width)

NoticeFroth-Pak™ Foam Sealant complies with the following codes:

Contact your DuPont sales representative or local authorities

for state and local building code requirements and related

acceptances.

HANDL ING

Froth-Pak™ Foam Sealant will adhere to most surfaces and

skin. Do not get foam on the skin. Wear protective clothing

(including long sleeves), gloves, and goggles. Cured foam

must be mechanically removed or allowed to wear off in time.

WARNING: CURED FOAM IS COMBUSTIBLE AND WILL

BURN IF EXPOSED TO OPEN FLAME OR SPARKS FROM

HIGH ENERGY SOURCES. These products should not be

sprayed where the foam may come into contact with hot

surfaces, such as heaters, furnaces, fireplaces, or recessed

lighting fixtures. The foam should NOT be exposed to

temperatures over 240F (116C).

Avoid overfilling restricted spaces. The reaction of these

chemicals causes expansion and may exert enough force to

cause an uncontrolled stream of foam, spraying the work area

and possibly the operator.

Froth-Pak™ Spray Polyurethane Foam contains isocyanate,

hydrofluorocarbon blowing agent, and polyol. Read all

instructions and (M)SDS carefully before use. Wear protective

clothing and cover all skin (including long sleeves), gloves,

goggles or safety glasses, and proper respiratory protection.

Do not breathe vapor or mist. Use only with adequate

ventilation.

Isocyanate is irritating to the eyes, skin, and respiratory

system, and may cause sensitization by inhalation or skin

contact.

Contents are under pressure.

Precautionary Statements

WARNING: For Professional Use Only

Read and follow the entire Handling section and the Safety Data Sheets (SDSs, formerly MSDSs or Material Safety Data Sheets)

carefully before use. The information below is designed to protect the user and allow for safe use and handling of DuPont™

products. Follow all applicable federal, state, local and employer regulations.

Personal protective equipment (PPE) used during the handling of

Froth-Pak™ products must at a minimum include:

Protective clothing including long sleeves, gloves, and

goggles.

RECOMMENDED – Supplied air or an approved air-purifying

respirator equipped with an organic vapor sorbent and a

particulate filter to maintain exposure levels below ACGIH,

OSHA, WEEL or other applicable limits.

IF ATMOSPHERIC LEVELS EXCEED THE LEVEL FOR

WHICH AN AIR-PURIFYING RESPIRATOR IS EFFECTIVE –

A positive pressure, air-supplying respirator such as an air

line or self-contained breathing apparatus.

Personal Protective Equipment (PPE)

Disposal

Dispose of any residual DuPont™ product, coated debris, or

solvent in accordance with applicable federal, state, and local

government regulations.

Legacy Formulation

Page 6: Froth-Pak Old Formulation Insulation Sell Sheet

For more information visit frothpak.com/insulation or call 1-866-583-2583

NOTICE: No freedom from any patent owned by DuPont or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer’s use and for ensuring that Customer’s workplace and disposal practices are in compliance with applicable laws and other government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where DuPont is represented. The claims made may not have been approved for use in all countries or regions. DuPont assumes no obligation or liability for the information in this document. References to “DuPont” or the “Company” mean the DuPont legal entity selling the products to Customer unless otherwise expressly noted. NO EXPRESS WARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE WRITTEN WARRANTIES SPECIFICALLY PROVIDED BY DUPONT. ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. The buyer assumes all risks as to the use of the material. Buyer’s exclusive remedy or any claim (including without limitations, negligence, strict liability, or tort) shall be limited to the refund of the purchase price of the material. Failure to strictly adhere to any recommended procedures shall release DuPont Specialty Products USA, LLC or its affiliates, of all liability with respect to the materials or the use thereof. The information herein is not intended for use by non-professional designers, applicators or other persons who do not purchase or utilize this product in the normal course of their business.

CAUTION: This product is combustible. Protect from high heat sources. A protective barrier or thermal barrier may be required as specified in the appropriate building code. For more information, consult (Material) Safety Data Sheet ((M)SDS), call DuPont at 1-866-583-2583 or contact your local building inspector. In an emergency, call 1-989-636-4400 in the U.S. or 1-519-339-3711 in Canada.

WARNING: Rigid foam insulation does not constitute a working walkable surface or qualify as a fall protection product.

FROTH -PAK ™ Spray Polyurethane Foam contains isocyanate, hydrofluorocarbon blowing agent and polyol. Read the instructions and Material Safety Data Sheets carefully before use. Wear protective clothing (including long sleeves), gloves, goggles or safety glasses, and proper respiratory protection. Building and/or construction practices unrelated to building materials could greatly affect moisture and the potential for mold formation. No material supplier including DuPont can give assurance that mold will not develop in any specific system.

DuPont™, the DuPont Oval Logo, and all trademarks and service marks denoted with ™, SM or ® are owned by affiliates of DuPont de Nemours, Inc. unless otherwise noted. © 2020 DuPont. 43-D100067-enUS-0120 CDP