1
REPORT NO : Mock Up DATE : 19/10/2013 PAGE NO. : 1 of 10 MANUFACTURER PROCEDURE WELD PREPARATION WELDING PROCESS COUPLANT TECHNIQUE LOCATION NOMINAL THICKNESS FLAW DETECTOR/ MANUFACTURER/ SERIAL NO SEARCH UNIT CABLE/ TYPE/LENGTH/ COMPUTERIZED PROGRAM CALIBRATION DATA FIRST ELEMENT LAST ELEMENT TOTAL ELEMENT APERTURE(A) INDEX OFFSET MIN ANGLE MAX ANGLE REVIEWED BY (Client) NAME : INSPECTED BY : ASNT LEVEL II NAME : ARUN RAJENDRAN AREAS OF RESTRICTED ACCESS NA 15MM 53.00MM 50 70 1 16 16 MXU WELD 3.1 R3 V1 BLOCK STAINLESS STEEL / 8" 23.0 MM SDH AND NOTCH FOCAL DEPTH OLYMPUS/SA15-N60S-IH LUMUT, PERAK 23.00MM OMNISCAN MX / OLYMPUS / S/N:OMNI2-100207 PROBES/SERIAL NO/ MANUFACTURER/ FREQUENCY/SIZE 7.5CCEV35-A15/OLYMPUS/7.5MHZ 16 ELEMENT OLYMPUS PHASED ARRAY PROBE CABLE/ 16 EL / 2.5m SPECIAL EQUIPMENT/ WEDGES/ENCODERS/ 31.1dB IDENTIFICATION OF LOCATION OF WELD AND VOLUME DATA CORRELATING SIMULATION BLOCK: V1 BLOCK STAINLESS STEEL / 8" 23.0 MM SDH AND NOTCH PLEASE REFER TO THE SCANS INSTRUMENT REFERENCE LEVEL GAIN NA SUPER DUPLEX STAINLESS STEEL CALIBRATION BLOCK V1 BLOCK STAINLESS STEEL / 8" 23.0 MM PIPE WITH SDH AND NOTCH WELDER NO NA AS WELDED / NOT PAINTED SPECIFICATION EW/OP/084 HEAT TREATMENT MATERIAL TYPE AS PER DRAWING CELLULOSE WALL PAPER PASTE GTAW SURFACE CONDITION SAPURA KENCANA PROJECT: Mockup for GWF OLYMPUS - OMNISCAN MX2 MOCKUP EQUIPMENT NA NA EW PROJECT CODE CLIENT : SAPURA KENCANA NA JOINT NO LINE NUMBER PHASED ARRAY 100 PROPAGATION SHEAR RESULTS: Please refer to the inspection summary PROBE TO CENTRELINE 53.00MM THICKNESS 23.00MM PULSE WIDTH AUTO START ANGLE 50 Calibration:- Using the provided calibration block, calibrate all beams for TCG using a 80% reference. Scanning sensitivity to be TCG +12 dB 70 STOP ANGLE

FRONT PAGE Mockup Report.pdf

Embed Size (px)

DESCRIPTION

PAUT

Citation preview

Page 1: FRONT PAGE Mockup Report.pdf

REPORT NO : Mock Up

DATE : 19/10/2013

PAGE NO. : 1 of 10

MANUFACTURER

PROCEDURE

WELD PREPARATION

WELDING PROCESS

COUPLANT

TECHNIQUE

LOCATION

NOMINAL THICKNESS

FLAW DETECTOR/

MANUFACTURER/

SERIAL NO

SEARCH UNIT CABLE/

TYPE/LENGTH/

COMPUTERIZED

PROGRAM

CALIBRATION DATA

FIRST ELEMENT

LAST ELEMENT

TOTAL ELEMENT

APERTURE(A)

INDEX OFFSET

MIN ANGLE

MAX ANGLE

REVIEWED BY (Client)

NAME :

INSPECTED BY : ASNT LEVEL II

NAME : ARUN RAJENDRAN

AREAS OF RESTRICTED

ACCESSNA

15MM

53.00MM

50

70

1

16

16

MXU WELD 3.1 R3

V1 BLOCK STAINLESS STEEL /

8" 23.0 MM SDH AND NOTCH

FOCAL DEPTH

OLYMPUS/SA15-N60S-IH

LUMUT, PERAK

23.00MM

OMNISCAN MX / OLYMPUS /

S/N:OMNI2-100207

PROBES/SERIAL NO/

MANUFACTURER/

FREQUENCY/SIZE

7.5CCEV35-A15/OLYMPUS/7.5MHZ

16 ELEMENT

OLYMPUS PHASED ARRAY PROBE

CABLE/ 16 EL / 2.5m

SPECIAL EQUIPMENT/

WEDGES/ENCODERS/

31.1dB

IDENTIFICATION OF

LOCATION OF WELD

AND VOLUME

DATA CORRELATING

SIMULATION BLOCK:

V1 BLOCK STAINLESS STEEL /

8" 23.0 MM SDH AND NOTCH

PLEASE REFER TO

THE SCANS

INSTRUMENT

REFERENCE LEVEL GAIN

NA

SUPER DUPLEX STAINLESS STEEL

CALIBRATION BLOCKV1 BLOCK STAINLESS STEEL /

8" 23.0 MM PIPE WITH SDH AND NOTCH

WELDER NO NA

AS WELDED / NOT PAINTED

SPECIFICATION

EW/OP/084 HEAT TREATMENT

MATERIAL TYPE

AS PER DRAWING

CELLULOSE WALL PAPER PASTE

GTAW

SURFACE CONDITION

SAPURA KENCANA

PROJECT: Mockup for GWF

OLYMPUS - OMNISCAN MX2

MOCKUP

EQUIPMENT

NA

NAEW PROJECT CODE

CLIENT : SAPURA KENCANA

NAJOINT NO

LINE NUMBER

PHASED ARRAY

100

PROPAGATION SHEAR

RESULTS: Please refer to the inspection summary

PROBE TO CENTRELINE 53.00MM

THICKNESS 23.00MM

PULSE WIDTH AUTO

START ANGLE 50

Calibration:-

Using the provided calibration block, calibrate all beams for TCG using a 80% reference.

Scanning sensitivity to be TCG +12 dB

70STOP ANGLE