From stairways and ceilingsno noise will awake you.
Sound insulationSound insulation
for better solutions...
Peaceitself
H-BAUTechnik GmbH
Am Güterbahnhof 20D-79771 KlettgauDeutschlandTel. +49 (0) 77 42 / 92 15-20Fax +49 (0) 77 42 / 92 15-90eMail: [email protected]
Production east:Brandenburger StraßeD-14641 WachowDeutschlandTel. +49 (0) 332 92 / 775-20Fax +49 (0) 332 92 / 775-90eMail: [email protected]
Paul RiegerTel. +49 (0) 7742 / 9215-21Fax +49 (0) 7742 / 9215-93Mobil +49 (0) 171 / 864 72 61eMail: [email protected]
Klaus LangerTel. +49 (0) 26 64 / 58 54-41Fax +49 (0) 26 64 / 58 54-42Mobil +49 (0) 171 / 864 72 60eMail: [email protected]
Rudolf TillTel. +49 (0) 332 39 / 775-24Fax +49 (0) 332 39 / 775-90Mobil +49 (0) 172 / 993 70 50eMail: [email protected]
Peaceitself
SCHA
LL-I
SOBO
XContents
SCHALL-ISOBOX Type TSB Footstep noise insulation elements for stairwells 1
Footstep noise prevention / Requirements 2Design considerations 3Static systems TSB 4On-site reinforcement 6Installation instructions 7Footstep noise plates TSP 8
SCHALL-ISOSTEP Type HT-V The acoustic isolation of staircase and landing 9
Sections and design information 12On-site reinforcement 13Installation instructions 14
SCHALL-ISOTRITT Type Z Footstep noise mounting elements for prefabricated staircases 15
SCHALL-ISODORN Type JSD Type JSD for spiral staircases and landings 17
Locally cast or prefabricated landing 19Delivery range 22
Installation instructions 24
Requirement specification texts Schall-Iso footstep noise prevention box TSB 25
Schall-Isostep Type HT-V 26Schall-Isotritt 27Schall-Isodorn JSD 28
Sound insulationFrom stairways and ceilings no noise will awake you.
Peaceitself Sound insulation
NOTES
SCHALL-ISOBOXFootstep noise insulation elements for stairwells
Peaceitself
1
SCHA
LL-I
SOBO
X
SCHALL-ISOBOXSCHALL-ISOBOXTType TSBype TSB
Peaceitself SCHALL-ISOBOX
Footstep noise insulation elements for stairwells
2
Footstep noise preventionWith TSB footstep noise preventionboxes, an acoustic decoupling of thestairwell installation from the livingareas is achieved.TSB footstep noise prevention boxescan equally well be installed in brick-work or concrete walls. Prefabricatedlandings with integral TSB footstepnoise prevention boxes as mountingpoints are easy to lay and preventfootstep noise bridges.
Noise prevention require-ments stairsAccording to DIN 4109, Supplement2, Requirements for increased NoisePrevention, the following 5 require-ments with regard to the differentcomponents should be observed.
Ln,w = weighted standard footstep noise level
TSM = footstep noise prevention resonance
Component Requirements acc. to Achievable value withDIN 4109, Supplement 2 Schall-Isobox Type TSB
Staircase without floating req. L’n,w ≤ 46 dB = 38 dB o.K.screed, req. TSM ≥ 17 dB = 25 dB o.K.separate from landing
Staircase without req. L’n,w ≤ 46 dB = 38 dB o.K.floating screed req. TSM ≥ 17 dB = 25 dB o.K.
Vestibule/stairway doorsand wall section see DIN 4109, Chapter 3, Table 2with door
Stairwell walls single-skin see DIN 4109, Supplement 2, Chapter 3.1, Table 2
Outside wall see DIN 4109, Chapter 5.2, Table 8 (Note correction values)
The thickness of the landing can be18 cm or 20 cm. Positive and nega-tive as well as horizontal transverseforces can be absorbed with theindividual types. The max. supportpressure is 2.75 N/mm2.
L n,w ≤ 38 dB
TSB Footstep noise plate – Qv
+/– Qh
+ Qv
TSB TSB TSB TSB
Footstep noise plateFootstep noise plate
TSB TSB TSB TSB
SCHALL-ISOBOXFootstep noise insulation elements for stairwells
Peaceitself
3
SCHA
LL-I
SOBO
XDesignations TSB
Typ TSB 55 F 11Design: 1 Ö Mounting bottom / 2 Ö Mounting bottom and top/
3 Ö Mounting bottom, top and side
Geometry: 1 Ö Landing thickness 18 cm / 2 Ö Landing thickness 20 cm
Installation: F Ö Prefabricated landingM+B Ö Brickwork and concreted walls
Loading: 55 Ö Maximum permissible transverse force in [kN]
Designation: Tritt-Schall-Box (footstep noise box)
TSB GeometryPlan view at top Plan view at base Vertical section
Maximum permissible support loadingsBottom support = +55,0 kN, *Top support = –15,0 kN, **Side support = ± 15,0 kN*additional top support with version 2 only, **additional top and side support with version 3 only
Type Height Height Width Width Depth Depthinternal external internal external internal external[mm] [mm] [mm] [mm] [mm] [mm]
11TSB 55 F 12 175-180 200 245 275 145-150 150-155
13
11TSB 55 M+B 12 175-180 200 245 275 145-150 150-155
13
21TSB 55 F 22 195-200 225 245 275 145-150 150-155
23
21TSB 55 M+B 22 195-200 225 245 275 145-150 150-155
23
*****
50
Peaceitself
4
SCHALL-ISOBOXFootstep noise insulation elements for stairwells
Static systems TSBBend-resistant design Articulated DesignLanding / Staircase Landing / StaircaseThe mounting points are to be reinforced as supportingbrackets.
The minimum joint width between the landing and the stairwell wall must be greater than 0.8 cm. The joint must becarefully examined for sound bridges. Optimum footstep noise prevention is achieved with the footstep noise plate inthe joint between the TSB elements.Every sound bridge reduces the footstep noise absorption of the TSB elements by ca. 3 - 5 dB.
Land
ing
thic
knes
s >
18 c
m
Joist
flus
h w
ith c
eilin
g
Joist
flus
h w
ith c
eilin
g
Joist
flus
h w
ith c
eilin
g
Land
ing
thic
knes
s >
18 c
m
SCHALL-ISOBOXFootstep noise insulation elements for stairwells
Peaceitself
5
SCHA
LL-I
SOBO
XLoad assumptions: Landing and staircase – according to DIN 1055 Part 3 –
Live load public buildings 5.0 kN/m2
Live load non-public buildings 3.5 kN/m2
Support situation: Landing – according to DIN 1045 Section 20.1.4 and leaflet 240 –
Load bearing width for field moment
t = TSB support width + 1/2 landing thickness
Load bearing width for transverse force at support
t = internal TSB box width
Maximum support forces for brickwork and concrete
Type TSB 55 max. Q in kN/support
Mortar group Thin bed Light-weight mortar Concretemortar
Ii IIa III IIIa LM21 LM36 B25kN kN kN kN kN kN kN kN
+Qv +20,0 +24,0 +28,0 +36,0 +16,0 +20,08 -Qv -5,0 -6,0 -7,0 - -9,0 -4,0 -5,0
±Qh ±5,0 ±6,0 ±7,0 ±9,0 ±4,0 ±5,0+Qv +24,0 +32,0 +36,0 +38,0 +40,0 +18,0 +22,0
12 -Qv -6,0 -8,0 -9,0 -9,5 -10,0 -4,5 -5,5±Qh ±6,0 ±8,0 ±9,0 ±9,5 ±10,0 ±4,5 ±5,5+Qv +32,0 +32,0 +48,0 +55,0 +55,0 +18,0 +22,0
20 -Qv -8,0 -9,5 -12,0 -15,0 -15,0 -4,5 -5,5±Qh ±8,0 ±9,5 ±12,0 ±15,0 ±15,0 ±4,5 ±5,5+Qv +36,0 +46,0 +55,0 +55,0 +55,0 +18,0 +22,0
28 -Qv -9,0 -11,5 -15,0 -15,0 -15,0 -4,5 -5,5±Qh ±9,0 ±11,5 ±15,0 ±15,0 ±15,0 ±4,5 ±5,5
+55,0-15,0±15,0
Loaddirection
Brickstrength
class
Peaceitself SCHALL-ISOBOX
Footstep noise insulation elements for stairwells
6
On-site reinforcement TSB
Plan viewLanding
SectionLanding slab
Detail of TSB reinforcement Detail of TSB reinforcement-view
Landing reinforce-ment to structuralengineer’s infor-mation
SCHALL-ISOBOXFootstep noise insulation elements for stairwells
Peaceitself
7
SCHA
LL-I
SOBO
XInstallation instructionsConcrete wall: Type TSB 55 M+B
Brickwork: Type TSB 55 M+B
1. Place the Schall-Isobox on the mortar bed.
2. Build over the Schall-Isobox.
3. Remove braces after the brickwork has set.
1. Mark the exact position of theSchall-Isobox on the shuttering.
2. Fix the base plate positively in thepreviously determined position bymeans of nails or screws.
3. Place the Schall-Isobox on thebase plate and apply pressureuntil the Schallbox is flush with theshuttering.
4. Concrete and seal the wall evenly.5. After removing the shuttering from
the wall, remove the braces com-pletely from the Schall-Isobox.
Prefabricated landing: Type TSB 55 F 1. When installing, observe the inscription TOP2. The Schall-Isobox can be placed in the shuttering of the prefabrication
immediately or on the pockets of the prefabrication retrospectively.3. The pockets of the prefabrication must maintain the following dimensions
Schall-Isobox Type TSB 55 F... H18 (H20)
Length = 240 mmHeight = 175 (195) mmDepth = 150 mm
The joints are to be examined carefully for sound bridges.
Peaceitself SCHALL-ISOBOX
Footstep noise insulation elements for stairwells
8
Footstep noise plates TSP 24 + TSP 32 self-adhesive on one side with peel-off foil
Landings + Brickwork + Concrete walls
1. Ensure that butt joints are properly sealed during installation. The founda-tion surface should be as free from dust as possible ( pre-coat with a deepsealer if necessary); in this way the best adhesion can be achieved.
2. TSP footstep noise plates can be glued to foundation surfaces such asbrickwork, concrete, steel, wood, rubber-type materials etc. without anyproblems.
3. Sizes of TSP footstep noise plates- TSP 24 for landings – face insulation towards the wall
Length of roll= 10000 mmHeight = 240 mmDepth = 8 mm
- TSP 32 für Treppenläufe – Seitendämmung zur WandRollenlänge = 10000 mmHöhe = 320 mmTiefe = 8 mm
4. Material properties- Closed cell PE foam, weather-resistant, UV-stabilised, highly resistant to
ageing, high density, high resistance to cracking- Single-sided full area adhesive surface with peel-off foi
5. Preparation- Can be cut to any required length using a sharp knife- Cover butt joints with ISO tape if necessary
Joist – entrance door Transition staircase – landing
TSB
Footstep noise plate – Qv
+/– Qh
+ Qv
Footstep noise plate
SCHALL-ISOSTEP Typ HT-VFootstep noise insulation elements for stairwells
Peaceitself
9
ISO
STEP
HT-
V
SCHALL-ISOSTEP SCHALL-ISOSTEP TType HType HT-V-V
Peaceitself SCHALL-ISOSTEP Typ HT-V
Footstep noise insulation elements for stairwells
10
Staircase connector Type HT-VStairs are usually constructed fromconcrete with a rigid connection tothe building. Their surface is oftenmade from stone or similar materialon account of the high resistance towear that is required. The conse-quence of this is that the noise ofpeople walking can be heard inneighbouring rooms due to the trans-mission of sound through the build-ing and time and again is objectedto as being unreasonable.In order to reduce the transmission ofthe noise of footsteps from the stairsto neighbouring sound-sensitiverooms to the levels permitted by DIN4109 in „remote living rooms”, itmust be ensured that, as far as possi-ble, stairs are not rigidly connectedto the building. The staircase connec-tor Type HT-V is used for the acousticdecoupling of the staircase and thelanding.
Static systemThe connection of the staircase to thelanding takes place in the form of anarticulated joint. Only transverse andhorizontal forces can be transmitted.The live load assumptions are to bechosen in accordance with DIN1055 Part 3. The Schall-Iso elementType HT-V serves to provide a posi-tive connection between, uniformlydistributed active loads.
Sizing table/type testedThe Schall-Iso element Type HT-Vconsists of an isolating body made ofgalvanised sheet steel and a fillingmaterial made from non-inflammableA1 material. In order to absorb thetransverse forces, ribbed concretereinforcing bars BSt 500NR areincorporated into the profile andbent at 77°. The horizontal forcesare transferred via the joint bymeans of two ribbed concrete rein-forcing bars BSt 500NR, which crossone another.The values are applicable to concreteof strength class ≥ B 25.
150
250
Scha
ll -
ISO
STEP
Scha
ll -
ISO
STEP
Type
HT-
V
Scha
ll -
ISO
STEP
Type
HT-
V
Scha
ll -
ISO
STEP
Type
HT-
V
C A
B DQ
Q
Type
HT-
V
L n,w ≤46 dB
The staircase is connected to thelanding by an articulated joint.Transverse and horizontal forces canbe transmitted. Tested for its fireprevention capabilities and catego-rised in fire resistance class F90.Assessment of noise prevention prop-erties by the ITA Wiesbaden.
Schall-Iso Element length Element height perm. transverse perm. horizontal Additional momentType [cm] [cm] force [kN/Element] force [kN/Element] [kN·m]
HT-4 V 90-125 16/18/20 26,4 ±4,75 0,58
HT-6 V 90-125 16/18/20 39,8 ±4,75 0,88
HT-8 V 90-125 16/18/20 52,8 ±4,75 1,17
Other element heights and lengths on request
The compression component from the diagonally fitted transverse force rods istransmitted via elastomer mountings. When sizing the connecting reinforce-ment on both sides of the Schall-Iso element, the moments due to the eccentricconnection must be taken into account. The moments resulting from the designloading must be superimposed upon these moments with the same sign.
SCHALL-ISOSTEP Typ HT-VFootstep noise insulation elements for stairwells
Peaceitself
11
ISO
STEP
HT-
V
Element construction
Schall-Iso Transverse force rods Horizontal rods Elastomer mounting eR eA eR eAType [Stk/Ø] [Stk/Ø] EPDM 70/70/10 [mm] [mm] [mm] [mm]
HT-4 V 4/6 2/6 2 ≥100 100 ≥200 200
HT-6 V 6/6 2/6 2 ≥100 100 ≥200 200
HT-8 V 8/6 2/6 2 ≥100 100 ≥200 100
Element length 90-150 cm Element length 151-200 cm
150
250
100 100100 100
900 - 2000
100 100100 100
900 - 2000
100 100100 100
900 - 2000
12
Type HT - 4 V
100 100100 100
900 - 2000
100 100
12
100100
Type HT- 8 V
100 100100 100
900 - 2000
100 100
12
Type HT - 6 V
Ø 6
Ø 6 Ø 6
Plan views
150
250
100 100100 100
900 - 2000
100 100100 100
900 - 2000
100 100100 100
900 - 2000
12
Type HT - 4 V
100 100100 100
900 - 2000
100 100
12
100100
Type HT- 8 V
100 100100 100
900 - 2000
100 100
12
Type HT - 6 V
Ø 6
Ø 6 Ø 6
150
250
100 100100 100
900 - 2000
100 100100 100
900 - 2000
100 100100 100
900 - 2000
12
Type HT - 4 V
100 100100 100
900 - 2000
100 100
12
100100
Type HT- 8 V
100 100100 100
900 - 2000
100 100
12
Type HT - 6 V
Ø 6
Ø 6 Ø 6
Peaceitself SCHALL-ISOSTEP Typ HT-V
Footstep noise insulation elements for stairwells
12
Sections and design information
Only the reinforced concrete components can be acoustically isolated using the Type HT-V Schall-Iso element. Furtherpoints of detail must be properly implemented in order to prevent continuous sound bridges.
– The connection between the landing covering and the staircase covering must be permanently elastic.
– The plaster on the underside of the landing or staircase must be interrupted in the area of the Schall-Iso element andmade permanently elastic.
– Landing and staircase must also be separated from the stairwell walls at the side, e.g. by means of the TSP self-adhesive footstep noise plate.
– A floating floor screed should be provided in the area of the landing.
1 Permanently elastic joint2 Footstep insulation3 Separating foil4 Floor screed5 Covering6 Edge insulation strip
First step
1
Landing
≥ B25
≥ B25
BSt 500NR35°
BSt 500NR
Ø 6
Staircase5
143
2
65
15°
Last step
Staircase
Landing
≥ 240
≥ B25
35°
BSt 500NR
Ø 6
10
BSt 500NR
15°
≥ B25
Ø 6
15 5
4
6
3
1
2
SCHALL-ISOSTEP Typ HT-VFootstep noise insulation elements for stairwells
Peaceitself
13
On-site reinforcement
Item 2 su
spension r
einforce
ment acco
rding to sta
tic calcu
lation
Item 6 mounting rod
Item 1 bottom re
inforce
ment acco
rding to sta
tic calcu
lation
Item 3 str
uctura
l reinfo
rcement
Item 4 edge stirrupmin. Ø 6/15
Item 5 stirrup Ø 6
Item 4 Item 5
Item 2
Item 1
Item 5 Item 4
Item 6
Item 3
Item 6
Item 4 edge stirrupmin. Ø 6/15
– A suspension reinforcement (Item 2) sized for the maximum transverse force is to be arranged at the end of thecomponent on the Schall-Iso Type HT-V in the connection of the load-carrying component.
– The face surfaces of the components to be connected must have an edging in accordance with DIN 1045 (07/88).(Item 4)
– The shear stresses in the components in the area where the load is applied must be limited to τ02 in accordance withDIN 1045, Tab. 13.
– A transverse reinforcement in accordance with DIN 1045, Number 18.5.2.3, must be installed in the area in whichthe transverse force rods are anchored. (Item 5 and 6).
– The bottom longitudinal reinforcement of the load-carrying component, which is to be brought up to the support, is to be taken as far as the Schall-Iso element (taking into account the concrete covering), bent upwards and ade-quately anchored. (Item 1).
– A static calculation must be carried out for the adjacent components at both ends.– The staircase is to be sized with articulated mountings at both ends.– When sizing the connecting reinforcement on both sides of the Schall-Iso element, the moments due to the eccentric
connection must be taken into account. The moments resulting from the design loading must be superimposed uponthese moments with the same sign.
ISO
STEP
HT-
V
Peaceitself SCHALL-ISOSTEP Typ HT-V
Footstep noise insulation elements for stairwells
14
Installation instructions
– Fit shuttering for staircase and landing.
– Cover the side-cheeks of the stair-case with Type TSP self-adhesivefootstep noise plate.
– If the landing is also acousticallydecoupled from the core of thestairwell by means of TSB footstepnoise boxes, here too the jointbetween the landing and the wallmust be made using a TSP foot-step noise plate.
– Nail the bottom U-section to thelanding shuttering.
– Slide the Schall-Iso element intothe U-section.
– Nail the top U-section onto a roof-ing lath and clamp to the Schall-Iso element.
– Align the Schall-Iso element verti-cally and fix to the shutteringcheeks or to the wall of the stair-well by means of the roofing lath.
– Lay the on-site reinforcement.– Fit the face shuttering for the steps
of the staircase.– Cast
Important:– The end hooks are always on the
stair side and point upwards.– The joint between the Schall-Iso
element Type HT-V and the foot-step noise plate Type TSP must beabsolutely tight in order to avoidpossible sound bridges.
– The U-sections must be removedafter casting.
Footstep noise plate Type TSP
150
250
On-site reinforcement (see P. 6)
Face shuttering
U-section
SCHALL - ISOSTEP Type HT-V
Footstep noise plate Type TSP
Footstep noise plate Type TSP
150
250
On-site reinforcement (see P. 6)
Face shuttering
U-section
SCHALL - ISOSTEP Type HT-V
Footstep noise plate Type TSP
Footstep noise plate Type TSP
150
250
On-site reinforcement (see P. 6)
Face shuttering
U-section
SCHALL - ISOSTEP Type HT-V
Footstep noise plate Type TSP
Peaceitself
15
SCHALL-ISOTRITT ZFootstep noise mounting elements for prefabricated staircases
ISO
TRIT
T Z
SCHALL-ISOTRITTSCHALL-ISOTRITTTType Zype Z
Peaceitself SCHALL-ISOTRITT Z
Footstep noise mounting elements for prefabricated staircases
16
177
55
255
5
5 10
80 - 120 / L
2025
Foam material
Compression support / Stair mounting
Buffer stop6/A 10/B
17/C
Schall-Isotritt Type Z for first and last steps Schall-Isotritt Typ ZB for staircase/floor slab
1
25 36255 5
≤ 24
≥7
10
compression support
noise mounting Type Zbuffer stop
floor coveringfloor screedinsulationlanding
permanently elastic jointprefabricated staircase
permanently elastic jointfloor coveringfloor screedinsulationfloor slab
compression support
noise mounting Type ZB
prefabricated staircase
Detail of first step/landing Detail of first step/floor slab
permanently elastic joint
floor coveringfloor screedinsulationlanding
landing
prefabrica
ted sta
ircase
compression supportnoise mounting Type Z
buffer stop
≤ 24
≥7
10
Detail of last step/landing
Permissible loadings and dimensions Type Z and Type ZB
mounting Staircase width Mounting size Vertical Horizontaltype loading loading
[cm] [mm] [kN] [kN]
Type Z10 080-100 vertical2x(250x50x10)
Type Z12 100-120 horizontal 50,0 6,252x(50x50x10)
Type ZB 10 080-100 vertical2x(250x50x10)
Type ZB 12 100-120 50,0
Other lengths and dimensions(A, B, C, L) on request
Axis of staircase foot
Delivery form36 / B
80 120 / L
Section
SCHALL-ISODORN JSDType JSD for spiral staircases and landings
Peaceitself
17
Mit uns geht’s rund...... und eckig
ISO
DO
RN
JSD
SCHALL-ISODORNSCHALL-ISODORNTTypeype JSDJSD
Peaceitself SCHALL-ISODORN JSD
Footstep noise insulating elements for stairwells
18
SCHALL-ISODORN JSD
– increased protection againstfootstep noise in accordancewith DIN 4109, Supplement 2at least Ln,w ≤ 46 dB
– type-tested with integral trans-verse force pin
– transverse force pins with DIBT Z-15.7-99 approval
An acoustic decoupling of the stair-well installation from the living areasis achieved with SCHALL-ISODORNType JSD.
SCHALL-ISODORN Type JSD can beinstalled both in brickwork and inconcrete walls.
SCHALL-ISODORN Type JSD SO SCHALL-ISODORN Type JSD SF
The two versions
– for local castingSCHALL-ISODORN Type JSD SO
– for prefabricated componentsSCHALL-ISODORN Type JSD SF
simplify the previous method of run-ning reinforcement to the TSB foot-step noise prevention box and openup new possibilities in connecting tospiral staircases or prefabricatedlandings.
Especially when combining retro-spectively laid prefabricated stair orlanding components, SCHALL-ISODORN boxes can be easily fittedin the walls of the stairwell on siteby means of recessed pockets.
Footstep noise bridges are preventedtogether with the self-adhesive TSPfootstep noise protection plates.
The thickness of the landing can be18 cm or 20 cm. The SCHALL-ISODORN Type JSD SO can be usedfor spiral staircases from a side-cheek thickness of 12 cm. Positiveand negative transverse forces canbe absorbed by the individual types.If horizontal transverse forces are tobe absorbed, these can be struc-turally accommodated by TSP-Hfootstep noise protection plates orwith SCHALL-ISODORN boxes andintegral horizontal mountings.
ISO
DO
RN
JSD
SCHALL-ISODORN JSDFootstep noise insulating elements for stairwells
Peaceitself
19
Design considerations for locally cast landing designor integral with prefabricated landing
JSD 20 SO JSD 22 SO
266
200
160
266
220
160Landing thickness at least 18 cm Landing thickness at least 20 cm
266
200
160
266
220
160
Landing thickness at least 18 cm Landing thickness at least 20 cm
266
200/
220
160
266
200/
220
160
Type JSD SOmax. Q in kN support/bearing
concrete quality at least B25 (B35)
JSD 20 SO JSD 22 SO
kN kN
Standard+ 36,0 + 43,5+ Qv
Pressure on1,8 N/mm2 2,2 N/mm2
mounting
Special + 36,0 + 43,5+ Qv +/– 15,0 +/– 15,0±Qh
Table of permissibletransverse forces
For further dimensions, see type test / approval
QV
QH
QV
QH
Design considerations for prefabricated landing design/boxes for installation on site
JSD 20 SF JSD 22 SF
Box with round sleeve Box with rectangular sleeve
JSH 20 SFJSH 22 SF
JSHQ 20 SFJSHQ 22 SF
Type JSD SFmax. Q in kN support/bearing
concrete quality at least B25
JSD 20 SF JSD 22 SF
kN kN
Standard+ 34,4 + 37,5+ Qv
Standard req.imposed load – 14,2 – 15,5
– Qa
Pressure on3,65 N/mm2 4,0 N/mm2
mounting
Special + 34,4 + 37,5+ Qv +/– 15,0 +/– 15,0±Qh
Table of permissible transverse forcesValues also apply to Type JSH SFand Type JSHQ SF
Anchor reinforcement in theside-cheek sleeve
Arrangement of reinforcementsee Table
Peaceitself SCHALL-ISODORN JSD
Footstep noise insulating elements for stairwells
20
Installation variants, locally cast design JSD SO
≥ 0 ≤ 2 cm
16
Plan view Plan view SectionStaircase with articulated mounting Clamped staircase Wall mounting
Installation variants, locally cast design JSD SF
locally cast/prefab component
Box with sleeve
Insertspacer plates
Slide box into position
Insertspacer plates
Pin JSD
≥ 0 ≤ 2 cm
≥ 0 ≤ 5mm
locally cast /prefab component
Box with sleeve
Nail strip
Installation: Box with recessed opening
Staircase section, wall mounting Installation with spiral staircases
SCHALL-ISODORN JSDFootstep noise insulating elements for stairwells
Peaceitself
21
ISO
DO
RN
JSD
Required suspension and punch-through reinforcementLanding/Staircase, DIN 1045, Section 22.5The reinforcement given in the type test represents a full utilisation of the permissible loadings on the transverse force pins.If lower transverse forces are transmitted, the required punch-through reinforcement in accordance with the approval canbe taken from the table below.
Type JSD SO
Type JSD SF
Type JSD SOmax. Q in kN mounting/support – concrete quality at least B25 (B35)
JSD 20 SO JSD 20 SO JSD 20 SO JSD 20 SO JSD 22 SO JSD 22 SO JSD 22 SO JSD 22 SOperm. Q perm. Q perm. Q perm. Q perm. Q perm. Q perm. Q perm. Q
in kN in kN in kN in kN in kN in kN in kN in kNStandard
+ 36,0≤ + 30,6 ≤ + 23,2 ≤ + 18,3
+ 43,5≤ + 36,6 ≤ + 30,6 ≤ + 27,7
+Qv (≤ + 36,0) (≤ + 27,7) (≤ + 22,0) (≤ + 43,5) (≤ + 36,8) (≤ + 32,7)Suspension
reinforcement 2 Ø 12 2 Ø 12 2 Ø 12 2 Ø 12 2 Ø 12 2 Ø 12 2 Ø 12 2 Ø 12Item 1Stirrup
2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10Item 2 V. E.
2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10Item 3Req. Asx
2x3 Ø 10 2x1 Ø 10 2x1 Ø 10 2x1 Ø 10 2x3 Ø 10 2x1 Ø 10 2x1 Ø 10 2x1 Ø 10Item 4Req. Asy
2x3 Ø 8 2x3 Ø 8 2x1 Ø 8 1 Ø 8 2x3 Ø 8 2x3 Ø 8 2x1 Ø 8 1 Ø 8Item 5
Type JSD SFmax. Q in kN mounting/support – concrete quality at least B25 (B35)
JSD 20 SF JSD 20 SF JSD 20 SF JSD 20 SF JSD 22 SF JSD 22 SF JSD 22 SF JSD 22 SFperm. Q perm. Q perm. Q perm. Q perm. Q perm. Q perm. Q perm. Q
in kN in kN in kN in kN in kN in kN in kN in kNStandard
+ 34,4≤ + 30,6 ≤ + 23,2 ≤ + 18,3
≤ + 37,5≤ + 36,2 ≤ + 28,7 ≤ + 20,3
+Qv (≤ + 34,4) (≤ + 27,7) (≤ + 22,0) (≤ + 37,5) (≤ + 34,4) (≤ + 24,3)Standard req. ≤ – 13,5 ≤ – 9,5 – 7,6 ≤ – 14,9 ≤ – 11,9 ≤ – 8,4imposed load – 14,2 –15,5
– Qa (≤ – 14,2) (≤ – 11,5) (≤ – 9,1) (≤ – 15,5) (≤ – 14,2) (≤ – 10,1)
Suspensionreinforcement 2 Ø 12 2 Ø 12 2 Ø 12 2 Ø 12 2 Ø 12 2 Ø 12 2 Ø 12 2 Ø 12
Item 1Stirrup
2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10Item 2 V. E.
2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10 2 Ø 10Item 3Req. Asx
2x3 Ø 10 2x1 Ø 10 2x1 Ø 10 2x1 Ø 10 2x3 Ø 10 2x1Ø 10 2x1 Ø 10 2x1 Ø 10Item 4Req. Asy
4 Ø 8 4 Ø 8 2 Ø 8 1 Ø 8 4 Ø 8 4 Ø 8 2 Ø 8 1 Ø 8item 5
Peaceitself SCHALL-ISODORN JSD
Footstep noise insulating elements for stairwells
22
Delivery range Type JSD
Standard design:
Locally cast:: Type JSD 20 SO, Type JSD 22 SO
Prefabricated design: Type JSD 20 SF, Type JSD 22 SF
Box with round sleeve incl. pin Type JSH 20 SF, Type JSH 22 SF
Box with rectangular sleeve incl. pin Type JSHQ 20 SF, Type JSHQ 22 SF
For use in walls to be cast with fixing angles:
Type JSD 20 SFB, Type JSD 22 SFB
Box with round sleeve incl. pin Type JSH 20 SFB, Type JSH 22 SFB
Box with rectangular sleeve incl. pin Type JSHQ 20 SFB, Type JSHQ 22 SFB
Compensating shims, galvanised Shim 1 mm thick W x L = 270 mm x 160 mmShim 3 mm thick W x L = 270 mm x 160 mmShim 5 mm thick W x L = 270 mm x 160 mm
Footstep noise plates 8 mm thick with integral horizontal mounting 50 x 100 x 10self-adhesive, permissible H = +/– 15 kN
TSP 24 H H x L x T = 240 x 200 x 8mmTSP 32 H H x L x T = 320 x 200 x 8mm
Staircase
Landing
TSP plate
TSP plate
≥ 135 JSD20≥ 150 JSD22
≥ 270 JSD20≥ 300 JSD22
≥ 135 JSD20≥ 150 JSD22
Stairwell wallconcrete / brickwith load distributor
Schall-Isodorn JSD SO/SF
Stairwell wallconcrete / brickwith load distributor
Stairwell wallconcrete / brick
Plan view of stairwell
Schall-Isodorn JSD SO/SF
Staircase
TSP plate
SCHALL-ISODORN JSDFootstep noise insulating elements for stairwells
Peaceitself
23
ISO
DO
RN
JSD
la =110 (JSD20)130 (JSD22)
SleeveItem 3 Item 5
≥ B25
Item 2 Item 1,4
Item 5Item 3
Shear pin
155
180/
200*
Type SFPositions of on-site reinforcement
Type SO (as Type SF)
35 110 20
242
155
10 20
30
Item 5
Item 2 Item 4 3→10
JSD22
JSD20
1,5x
hm70
/80
Item 1
Footstep noise plate TSP
Item 3→10Item 3
1,5x
hm
≥ 476
Item 1 Stirrup 2→12
item 4 Stirrup 6→10 (ASX)
120/
140*
120/
140*
400
* for landing height 20 cm
Item 3 2→10 item 5 2x3→8 (ASY)
400
140/
160*
Item 2 Stirrup 2→10
Section
Plan viewType SO (as Type SF)
Peaceitself SCHALL-ISODORN JSD
Footstep noise insulating elements for stairwells
24
Installation instructions
max. joint opening 0.5 cm
compensating shim
Prefabricated landings with Type JSD SF
1. When installing, observe the inscription top.
2. The JSD SF boxes are arranged in the recessed openings. It must beensured that the top and bottom of the JSD SF box are arranged positivelyand snugly in the recess. The JSD SF box can be laid on the brickwork witha tolerance of 2 cm. If the elastomer mounting is arranged flush with thefront edge of the wall, compensating shims are to be used in all cases.
3. The recess opening should have the following dimensions
Length ≥ 300 mmHeight ≥ 250 mmDepth ≥ 170 mm
4. The max. width of joint between the prefabricated landing and the JSD SFbox is 0.5 cm. The joint is to be carefully examined for sound bridges.Optimum footstep noise prevention is achieved with the footstep noise platein the joint between the brickwork and the SCHALL-ISODORN elements.Every sound bridge reduces the footstep noise absorption of the JSDelements by ca. 3 - 5 dB.
5. For the installation of the JSH SFB or JSHQ SB box with integral sleeve inwalls to be cast, an angled plate is incorporated in the box for fitting to theshuttering.
6. For the required reinforcement on site, see type test.
7. Dimensional tolerances can be taken into account by means of compen-sating shims.
Prefabricated landings with Type JSD SO
1. When installing, observe the inscription top.2. The JSD SO boxes are arranged in the plane of the wall with a tolerance
of 2 cm. Dimensional tolerances can be taken into account by means ofcompensating shims. This can also be undertaken using a compensatingmortar. The JSD SO box can be laid on the brickwork with a tolerance of 2 cm. If the elastomer mounting is arranged flush with the front edge of thewall, compensating shims are to be used in all cases.The landings are to be cast locally.
3. For the required reinforcement on site, see type test.
ÝÝ
Slide boxinto position
Tolerance 2 cm
Type JSD SF joint 0.5 cm
Type JSD SF Tolerance 2 cm
Type JSH SFB, JSHQ SFB
SCHALL-ISOfootstep noise prevention box TSB
Requirement specification
Peaceitself
25
REQU
IREM
ENT
SPEC
IFIC
ATIO
N TE
XTS
12/9
8
Service area Area of application: DIN 276012 Masonry work n Stair constructions013 Concrete and reinforced concrete work n Main and intermediate landings
SCHALL-ISO Footstep noise prevention box TSB
01 Supply and install H-BAU Technik Horstmann GmbH footstep noise prevention boxTSB in accordance with the architect's or engineer's installation plan.Apart from the connection by means of SCHALL-ISO Type TSB, a perfect isolation of the landing and the staircase from the walls of the stairwell must be guaranteed.For further information, see manufacturer's connection details. No sound bridges mustbe created..
02 Landing thickness D = ........... cm03 ....... off H-Bau Technik SCHALL-ISO Type TSB55 / F
footstep noise prevention box for prefabricated landingsW x H x D = 250 x H x 150 mm, height dependent upon the thickness of the landing.
04 ....... off H-Bau Technik SCHALL-ISO Type TSB55 / M + Bfootstep noise prevention box for brick walls and concrete wallsW x H x D = 250 x H x 150 mm, height dependent upon the thickness of the landingW x H x D = 250 x H x 150 mm, height dependent upon the thickness of the landing
05 Compression mounting bottom Version 1 06 Compression mounting bottom and top Version 207 Compression mounting bottom, top and side Version 308 ....... m footstep noise plates TSP 24, H x D = 240 x 8 mm09 ....... m footstep noise plates TSP 32, H x D = 320 x 8 mm10 Supply and install11 Installation only. Supplied on site.12 Installation in accordance with information from H-BAU Technik GmbH
Am Güterbahnhof 2079771 Klettgau-ErzingenTel.: 0 77 42 / 92 15-20Fax: 0 77 42 / 92 15-90
The application information must be observed.13 Material ....................14 Labour ....................15 Individual price ....................16 Total price ....................
Peaceitself SCHALL-ISOSTEP Type HT-V
Requirement specification
26
Leistungsbereich : Area of application: DIN 276012 Masonry work n Stair constructions013 Concrete and reinforced concrete work n Main and intermediate landings
SCHALL-ISOSTEP Type HT-V
01 Footstep noise prevention in accordance with DIN 4109, Supplement 2, increased noiseprevention. H-BAU Technik Horstmann GmbH footstep noise insulation element Type HT-V in the locally cast or prefabricated staircase according to the static calculation.Installation of on-site reinforcement in accordance with the type test. Reinforcement will be paid for separately.Apart from the connection by means of SCHALL-ISOSTEP Type HT-V, a perfect iso-lation of the landing and the staircase from the walls of the stairwell must be guaranteed.For further information, see manufacturer's connection details.No sound bridges must be created.
02 Landing thickness D =...................cm ó element height03 ....... off H-Bau Technik SCHALL-ISOSTEP Type HT-V-404 ....... off H-Bau Technik SCHALL-ISOSTEP Type HT-V-605 ....... off H-Bau Technik SCHALL-ISOSTEP Type HT-V-806 ....... off H-Bau Technik SCHALL-ISOSTEP Type HT-V-6/3 L=40 cm07 ....... off H-Bau Technik SCHALL-ISOSTEP Type HT-V-6/4 L=50 cm08 ....... off H-Bau Technik SCHALL-ISOSTEP Type HT-V-8/3 L=40 cm09 ....... off H-Bau Technik SCHALL-ISOSTEP Type HT-V-8/4 L=50 cm
10 ....... m, connection length staircase - landing slab ó element length(corresponds to staircase width)
11 Supply and install12 Installation only. Supplied on site.13 Installation in accordance with information from H-BAU Technik GmbH
Am Güterbahnhof 2079771 Klettgau-ErzingenTel.: 0 77 42 / 92 15-20Fax: 0 77 42 / 92 15-90
The application information must be observed.14 Material ....................15 Labour ....................16 Individual price ....................17 Total price ....................
SCHALL-ISOTRITTRequirement specification
Peaceitself
27
REQU
IREM
ENT
SPEC
IFIC
ATIO
N TE
XTS
Service area: Area of application: DIN 276012 Masonry work n Stair constructions013 Concrete and reinforced concrete work n Main and intermediate landings
SCHALL-ISOTRITT
01 Footstep noise prevention in accordance with DIN 4109, Supplement 2, increased noise prevention.H-BAU Technik Horstmann GmbH footstep noise insulation element Type Z and ZB formounting staircases to the landing.Apart from the connection by means of SCHALL-ISOTRITT, a perfect isolation of thelanding and the staircase from the walls of the stairwell must be guaranteed.For further information, see manufacturer's connection details.No sound bridges must be created
03 ....... off H-Bau Technik SCHALL-ISOTRITT Type Z 10Connection last step – landing, element length 1.00 m
04 ....... off H-Bau Technik SCHALL-ISOTRITT Type Z 12Connection last step – landing, element length 1.20 m
05 ....... off H-Bau Technik SCHALL-ISOTRITT Type ZB 10Connection first step – landing, element length 1.00 m
06 ....... off H-Bau Technik SCHALL-ISOTRITT Type ZB 12Connection last step – landing, element length 1.20 m
07 ....... off H-Bau Technik SCHALL-ISOTRITT Type Z SpecialA=.......cm, B=.......cm, C=.......cm, L=.......cm
08 ....... off H-Bau Technik SCHALL-ISOTRITT Type Z SpecialB=.......cm, L=.......cm
09 Supply and install10 Installation only. Supplied on site.11 Installation in accordance with information from H-BAU Technik GmbH
Am Güterbahnhof 2079771 Klettgau-ErzingenTel.: 0 77 42 / 92 15-20Fax: 0 77 42 / 92 15-90
The application information must be observed.12 Material ....................13 Labour ....................14 Individual price ....................15 Total price ....................
Peaceitself SCHALL-ISODORN JSD
Requirement specification
28
Service area: Area of application: DIN 276012 Masonry work n Stair constructions013 Concrete and reinforced concrete work n Main and intermediate landings
SCHALL-ISODORN JSD
01 SCHALL-ISODORN JSD SO for stair / landing mountings
02 Footstep noise prevention in accordance with DIN 4109, Supplement 2, increased noiseprevention.Supply and install Type JSD SO in locally cast or prefabricated landing according to static calculation incl. installation of the required punch-through reinforcement in accordance with Approval No. Z-15.7-99 or in accordance with the type test. The joint between the wall of the stairwell and the landing is to be acoustically decoupled by means of the self-adhesive footstep noise plate TSP or by an appropriate design of thejoint. The component is to be checked for footstep noise bridges. The staircase slabs are to be articulated or clamped.Manufacturer: H-BAU Technik GmbH
Am Güterbahnhof 2079771 Klettgau-ErzingenTel.: 0 77 42 / 92 15-20Fax: 0 77 42 / 92 15-90
03 ....... off SCHALL-ISODORN Type JSD 20 SO for landing thickness D at least 18 cm04 ....... off SCHALL-ISODORN Type JSD 22 SO for landing thickness D at least 20 cm
05 SCHALL-ISODORN JSD SF for spiral staircases / landing supportsFootstep noise prevention in accordance with DIN 4109, Supplement 2, increased noiseprevention.
06 Supply and install Type JSD SF in the area of the stairwell wall according to static calculation. If recessed openings are provided, the minimum dimensions must be maintained. The boxes are to be laid in mortar or on spacer shims. The dimensional tol-erances must be maintained. The required punch-through reinforcement in accordancewith Approval No. Z-15.7-99 or in accordance with the type test is to be provided in thespiral staircase or in the landing. The joint between the wall of the stairwell and the land-ing is to be acoustically decoupled by means of the self-adhesive footstep noise plateTSP or by an appropriate design of the joint. Check component for footstep noisebridges.Manufacturer: H-BAU Technik GmbH
Am Güterbahnhof 2079771 Klettgau-ErzingenTel.: 0 77 42 / 92 15-20Fax: 0 77 42 / 92 15-90
07 ....... off SCHALL-ISODORN Type JSD 20 SF for landing thickness D at least 18 cm08 ....... off SCHALL-ISODORN Type JSD 22 SF for landing thickness D at least 20 cm
09 SCHALL-ISOBOX with integral transverse force sleeve10 ....... off SCHALL-ISODORN for landing thickness D at least 18 cm11 ....... off SCHALL-ISODORN for landing thickness D at least 20 cm
SCHALL-ISODORN JSDNotes
Peaceitself
29
REQU
IREM
ENT
SPEC
IFIC
ATIO
N TE
XTS
Peaceitself SCHALL-ISODORN JSD
Notes
30
SCHALL-ISODORN JSDNotes
Peaceitself
31
REQU
IREM
ENT
SPEC
IFIC
ATIO
N TE
XTS
...Concreting with Systems
08/2
006
H-BAU Technik GmbHAm Güterbahnhof 20D-79771 Klettgau
Tel. + 49 (0) 77 42 / 92 15-20Fax + 49 (0) 77 42 / 92 15-90eMail: [email protected]
Produktion Nord – OstBrandenburger Strasse14641 Wachow
Tel. + 49 (0) 3 32 39 / 7 75-20Fax + 49 (0) 3 32 39 / 7 75-90eMail: [email protected]
JSD / HED Shear dowels
SCHALL-ISOSTEP Step soundproofed elements
SCHALL-ISOTRITT Step soundproofed bearings
SCHALL-ISOBOX Step soundproofed boxes
SCHALL-ISODORN Step soundproofed dowels
FERBOX®Reinforcement connectors
GRIPRIP®Masonry fixings
RIPINOX®Stainless reinforcement steel
FERNOX Stainless reinforcement steel
PENTAFLEX®Construction joint sealant
RAPIDOBAT®Shuttering tubes
ISOPRO®Cantilever slab connectors
UNIBORD®Shuttering
RAPIDOBORD®Shuttering
WARMBORD®Insulated shuttering
BOXFER®Reinforcement connectors
PRO BETON Concrete spacers