Friendly Inspection ServicesProperty Inspection Report
Cover Page
Sample reportInspection prepared for: Sample Report
Date of Inspection: 4/15/2015 Time: 12:30 Start, 3:15 finish Age of Home: 1986
Weather: Sunny, 66 degreesSample report
1986 home
Inspector: Harvey SansoucyMA License #28 NH License #258 VT License #143.0113065Friendly Inspection Services, 67 Mt. Gardner Rd., Bath, NH 03740
Email: [email protected]
Friendly Inspection Services Sample report
Page 1 of 26
Roof
Please understand that we cannot see through walls or enter crawl spaces that are less than 3 feet, nor can we enterattics that are not designed for safe passage. This inspection is not an assessment of building or electrical codes. This report does not guarantee the absence of wood boring insects. It is a visual, non destructive investigation forevidence of past or present wood boring insect activity. We are not responsible for insect damage that was concealed ornot accessible at the time of the inspection. If wood boring activity is discovered during the interior or exterior inspection itwill be noted on the report. No evaluation will be made regarding air, soil, lead, water, asbestos, formaldehyde, lead paint, molds, radon, pipingoutside the foundation or gas fittings or regulators. This report is not an engineering or building code study, and becauseof that we are not responsible for repairs to bring the building in compliance with current building codes. Only those components specifically mentioned in this report have been inspected and any other components notinspected are not part of this report and as such we make no statement regarding the condition of these un inspectedareas. You should evaluate and act on any comments before continuing with your purchase. This report is exclusive to you and is not transferable. LegendS = Satisfactory, component condition is functional and is consistent with its original purpose but may show signs ofnormal wear or deterioration.A= Acceptable, recommend upgrade, maintenance or may require repair or replacement within a short time.C= Concern, component is an area of concern or requires repair now.H= Hidden, component is not viewable using reasonable effort.NA = Does not apply to this inspection Basis of inspection This report is based on observations of the condition of the inspected building and components at the listed date andtime of the inspection. FRIENDLY INSPECTION does not give any warranty or guaranty. This report is made using thebest of our ability and judgement. Recommended action The summary at the end consists of potentially significant findings. These findings can be a safetyhazard, a deficiency requiring a major expenses to correct or items I would like to draw extraattention to. The summary is not a complete listing of all the findings in the report, and reflects theopinion of the inspector. Please review all of the pages of the report as the summary alone does notexplain all the issues. All repairs should be done by a licensed or bonded trade or profession. Irecommend obtaining a copy of all receipts, warranties and permits for the work done.
Roof ConditionS A C N/A H
XType of roof: GableMaterials: Asphalt shinglesBinocular inspection from ground • Multiple layers of roofing material present
ChimneyS A C N/A H
XChimney type: BrickRecommend applying a breathable masonry water repellent • Some spalling brick observed• Cracks observed at back side of chimney • Recommend increasing pitch of mortar cap andwash to better shed water • Consult a mason contractor
Friendly Inspection Services Sample report
Page 2 of 26
Exterior Areas
Roof penetrationsS A C N/A H
XRoof penetrations appeared to be in good condition
FlashingS A C N/A H
X
GuttersS A C N/A H
XGutter type: AluminumLoose gutter nails at right side of garage
Loose gutter nails at right side of garage
Entryway doors & WindowsS A C N/A H
X
Eaves & FaciaS A C N/A H
XLoose fascia observed at right side rake trim
Friendly Inspection Services Sample report
Page 3 of 26
Loose fascia observed at right side rake trimSoffits
S A C N/A H
X
Siding ConditionS A C N/A H
XSiding type: Wood clapboardDeteriorated at roof contact points • Recommend sealing holes & gaps around wallpenetrations with polyurethane caulking
Deteriorated at roof contact points Recommend sealing holes & gaps around wallpenetrations with polyurethane caulking
Corner boards and trimS A C N/A H
XRotted cupola
Friendly Inspection Services Sample report
Page 4 of 26
Grounds
Rotted cupolaExterior Paint
S A C N/A H
X
Bulkhead / walkoutS A C N/A H
XDamaged door latch, should be straightened to work properly
Exterior faucetS A C N/A H
XNot freeze resistant, should be shut off and drained each winter
Exterior electricalS A C N/A H
X
Exterior lightingS A C N/A H
XObserved in place
Grading & vegetationS A C N/A H
X
Driveway / walkwayS A C N/A H
XWalkway: PaversDriveway: Asphalt
Friendly Inspection Services Sample report
Page 5 of 26
Garage
Stairs and railingsS A C N/A H
XLocation & type: Front of building has concrete steps and landing
PatioS A C N/A H
XType: Covered patioCracked and settled floor slab
Garage typeType of garage: Attached
Siding & trim conditionS A C N/A H
XSiding type: Wood clapboard
Window conditionS A C N/A H
XWindow type: Double hung
Foundation & floorS A C N/A H
XFoundation wall type: ConcreteFloor type: ConcreteCrack observed at right side rear corner
Crack observed at right side rear cornerSills
S A C N/A H
XHidden by interior finish
Friendly Inspection Services Sample report
Page 6 of 26
Foundation / basement
Walls, ceilings / firewallsS A C N/A H
XType: Wood frame hidden by drywallWall surface type: DrywallCracks observed
ElectricalS A C N/A H
X
Garage doors & openerS A C N/A H
XType of door: Automatic door opener present • overhead doorsToo much down force at left door, needs adjustment • Electric eye safety system improperlyinstalled • Electric eye units too high, manufacturers recommend 6" from floor or less
Electric eye units too high, manufacturers recommend 6" from floor or lessExterior Door
S A C N/A H
X
Fire DoorS A C N/A H
X
Rafters & CeilingS A C N/A H
XBeneath living space
Roof ConditionS A C N/A H
X
Friendly Inspection Services Sample report
Page 7 of 26
FoundationS A C N/A H
XType of foundation: ConcreteObserved from outside, inside mostly concealed by insulation
Basement floorS A C N/A H
XFloor type: Concrete
Basement windowsS A C N/A H
X
ColumnsS A C N/A H
XType: Concrete filled steel
GirdersS A C N/A H
XType: Wood
SillsS A C N/A H
XType of sills: Wood
Floor joistsS A C N/A H
XType of joists: WoodBroken joist observed but appeared to be sound because of additional joist along side
Broken joist observed but appeared to be sound because of additional joist along sideSubfloor
S A C N/A H
XType of subfloor: Plywood
Friendly Inspection Services Sample report
Page 8 of 26
Electrical
Interior chimneyS A C N/A H
XChimney type: Metal
Bulkhead / walk out doorS A C N/A H
X
Water penetration and dampnessS A C N/A H
XMoisture: Efflorescence: no • Water stains: noBasement was dry at time of inspection
Sump pump & dehumidifierS A C N/A H
XNone present
Environmental hazardsS A C N/A H
XEnvironmental issues: None observed at time of inspection
ElectricalS A C N/A H
XMissing electrical box cover
Missing electrical box cover
Cable FeedsS A C N/A H
XService: Type: Aluminum, overhead service, drip loop, weatherhead, service entry cable,meter, inspected
Friendly Inspection Services Sample report
Page 9 of 26
Plumbing
Service panelS A C N/A H
XAmperage: 60 amp • 200 ampLocation: BasementPanel and sub panel inspected • Improper installation sub panel • Ground wire attached toneutral bus in sub panel • Consult a licensed electrician
Ground wire attached to neutral bus in sub panelBreakers / fuses
S A C N/A HType: Circuit breakersAmperage: 15 Amp • 20 Amp • 30 Amp • 60 AmpBreakers are listed for aluminum cable • Corrosion inhibitor observed
Number of breakersS A C N/A H
XVaries • Panels appear to be at or below their rated capacity
Branch circuitsS A C N/A H
XConductor materials: Copper • Multi strand aluminumWiring type: Non metallic sheathed cable
System groundS A C N/A H
XDriven rod • Bonded to building water piping
Water pipingS A C N/A H
XWater supply: Well supplies water • Plastic water service supply pipeType of pipe: CopperShut off located at well equipment
Condition of waste lines and supportsS A C N/A H
XType of piping: Plastic, ABS
Friendly Inspection Services Sample report
Page 10 of 26
Water Heater
Heat/AC
Water Heater ConditionS A C N/A H
XType: Indirect firedLocation: Basement
Water capacityRated capacity: 60 gallons
MakeMake: SuperStore
T & P valve and vacuum breakerS A C N/A H
XT & P valve and vacuum breaker observed in place
Exposed exhaust flueS A C N/A H
X
Heater EnclosureS A C N/A H
X
ThermostatsS A C N/A H
XFunctional • 2nd Floor thermostat loose on wall
Heating systemS A C N/A H
XHeating system type: Air handler for air conditioner • Oil fired hot water boilerDistribution method: Copper piping • Galvanized ductwork • Partly insulated
Flue pipe and damperS A C N/A H
XGalvanized flue pipe • Thimble observed
Fuel tankS A C N/A H
XOil tank, fill & vent pipes and feed pipe / filter inspected • End outlet tank, recommend thattank additive be used to remove any potential water
Air conditioningS A C N/A H
XLocation: Left side of buildingType: Electric2 Units inspected
Friendly Inspection Services Sample report
Page 11 of 26
Kitchen / dining area
AC service pipingS A C N/A H
XCompressor, service piping, electrical disconnect, compressor slab and condensate draininspected
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of flooring: Tile
Window ConditionS A C N/A H
XType of window: Casement • Stationary
Water temperatureS A C N/A H
XWater temperature: 138 degrees • Recommend lowering temperature for safety andeconomy reasons
Sink observationsS A C N/A H
X
PlumbingS A C N/A H
XIrregular materials used
CountersS A C N/A H
X
CabinetsS A C N/A H
X
ElectricalS A C N/A H
X
Friendly Inspection Services Sample report
Page 12 of 26
Laundry
GFCIS A C N/A H
XSome non GFCI receptacles, recommend that all kitchen receptacles be GFCI protected toreduce shock hazard
HVACS A C N/A H
XHeat source: Diffuser
Cook top conditionS A C N/A H
X
Oven & RangeS A C N/A H
X
Vent ConditionS A C N/A H
XType: Hood with fan
DishwasherS A C N/A H
X
RefrigeratorS A C N/A H
X
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of flooring: Concrete • VinylCracks observed in concrete floor
Friendly Inspection Services Sample report
Page 13 of 26
Interior Spaces
Cracks observed in concrete floorDoors
S A C N/A H
X
ElectricalS A C N/A H
X
HeatS A C N/A H
XHeat source: Hot water baseboard
Dryer VentS A C N/A H
X
Cross connectionsCross connections? No
PlumbingS A C N/A H
XRecommend using armored water supply hoses
Exterior doorS A C N/A H
X
Basement stairsS A C N/A H
XNot child safe, require proper railings
Friendly Inspection Services Sample report
Page 14 of 26
1/2 Bath
Stairs, railings & handrailsS A C N/A H
X
Alternate fuel heatersS A C N/A H
XType of heater: Propane fireplaceLocation of heater: Family room
Smoke DetectorsS A C N/A H
XSmoke and carbon monoxide detectors will be inspected by fire dept. prior to transfer ofproperty
Ceiling conditionS A C N/A H
XType of ceiling: Gypsum board
Wall conditionS A C N/A H
XType of walls: Gypsum board
Floor conditionS A C N/A H
XType of flooring: Tile
Door conditionS A C N/A H
X
SinksS A C N/A H
XWater temperature: 155 degrees • Recommend lowering temperature for safety andeconomy reasons
Plumbing conditionS A C N/A H
X
Counter conditionS A C N/A H
X
Cabinet conditionS A C N/A H
X
Friendly Inspection Services Sample report
Page 15 of 26
1st Floor bath
Toilet conditionS A C N/A H
X
Electrical conditionS A C N/A H
X
GFCIS A C N/A H
X
Bath exhaust fanS A C N/A H
X
HVACS A C N/A H
XHeat source: Hot water baseboard
Ceiling conditionS A C N/A H
XType of ceiling: Gypsum board
Wall conditionS A C N/A H
XType of walls: Gypsum board
Floor conditionS A C N/A H
XType of floor: Tile
Window conditionS A C N/A H
XType of wiindows: Double hung
Door conditionS A C N/A H
X
ElectricalS A C N/A H
X
Friendly Inspection Services Sample report
Page 16 of 26
Master bath
GFCIS A C N/A H
X
SinksS A C N/A H
XWater temperature: 135 degrees
PlumbingS A C N/A H
X
CountersS A C N/A H
X
CabinetsS A C N/A H
X
Tub / ShowerS A C N/A H
XWater temperature: 135 degreesTemperature at tub / shower should not excceed 111 degrees
Shower wallsS A C N/A H
XType: Fiberglass tub walls
Toilet conditionS A C N/A H
X
Bath exhaust fanS A C N/A H
X
HVACS A C N/A H
XHeat source: Hot water baseboard
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Friendly Inspection Services Sample report
Page 17 of 26
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of flooring: Tile
Window ConditionS A C N/A H
XType of window: Double hung
DoorsS A C N/A H
X
SinksS A C N/A H
XWater temperature: 134 degrees
PlumbingS A C N/A H
X
CountersS A C N/A H
X
CabinetsS A C N/A H
X
Tub / ShowerS A C N/A H
XWater temperature: 134 degreesTemperature at tub / shower should not excceed 111 degrees
Shower wallsS A C N/A H
XType: Fiberglass tub walls
ToiletsS A C N/A H
X
ElectricalS A C N/A H
X
Friendly Inspection Services Sample report
Page 18 of 26
Master bedroom
GFCIS A C N/A H
X
Exhaust FanS A C N/A H
XNone • Recommend that an exhaust fan be installed
HVACS A C N/A H
XHeat source: Diffuser • Hot water baseboard
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of flooring: Carpet
Window ConditionS A C N/A H
XType of window: Double hung
DoorsS A C N/A H
X
ClosetsS A C N/A H
X
ElectricalS A C N/A H
X
HVACS A C N/A H
XHeat source: Diffusers • Hot water baseboard
Friendly Inspection Services Sample report
Page 19 of 26
Left front bedroom
Left rear bedroom
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of floor: Carpet
Window ConditionS A C N/A H
XType of windows: Double hung
DoorsS A C N/A H
X
ClosetsS A C N/A H
X
ElectricalS A C N/A H
X
HVACS A C N/A H
XHeat source: Diffuser • Hot water baseboard
Ceiling ConditionS A C N/A H
XType of Ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
Type of floor: TileCracked grout
Friendly Inspection Services Sample report
Page 20 of 26
Middle bedroom
Window ConditionS A C N/A H
XType of windows: Double hung
DoorsS A C N/A H
X
ClosetsS A C N/A H
X
ElectricalS A C N/A H
X
HVACS A C N/A H
XHeat source: Diffusers • Hot water baseboard
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of flooring: Carpet
Window ConditionS A C N/A H
XType of window: Double hung
DoorsS A C N/A H
X
ClosetsS A C N/A H
X
Friendly Inspection Services Sample report
Page 21 of 26
Living room
Dining room
ElectricalS A C N/A H
X
HVACS A C N/A H
XHeat source: Diffusers • Hot water baseboard
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of flooring: Wood
Window ConditionS A C N/A H
XType of window: Double hung
ElectricalS A C N/A H
X
HVACS A C N/A H
XHeat source: Diffuser • Hot water baseboard
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of flooring: Wood
Friendly Inspection Services Sample report
Page 22 of 26
Family room
Window ConditionS A C N/A H
XType of window: Double hung
ElectricalS A C N/A H
X
HVACS A C N/A H
XHeat source: Diffusers • Hot water baseboard
Ceiling ConditionS A C N/A H
XType of ceiling: Gypsum board
Wall ConditionS A C N/A H
XType of walls: Gypsum board
Floor ConditionS A C N/A H
XType of flooring: Tile
Window ConditionS A C N/A H
XType of window: Double hung
ElectricalS A C N/A H
XHot & neutral reversed • Consult a licensed electrician
Friendly Inspection Services Sample report
Page 23 of 26
Attic
Hot & neutral reversedHVAC
S A C N/A H
XHeat source: Diffusers • Hot water baseboard
Exterior doorS A C N/A H
X
Screen DoorsS A C N/A H
X
AccessS A C N/A H
XType of access: Door • ScuttleFlat attic inspected from access only, walked in area over family room • Recommendinsulating and air sealing scuttle cover and door to attic
Attic structureS A C N/A H
XFraming type: Ceiling joists • Collar ties • RafterSheathing material: Plywood
ChimneyS A C N/A H
XNot visible
Attic PlumbingS A C N/A H
X
Friendly Inspection Services Sample report
Page 24 of 26
Duct WorkS A C N/A H
XInsulated ductwork
ElectricalS A C N/A H
XAttic light observed • Missing electrical box covers
Missing electrical box coversExhaust fan outlets
S A C N/A H Hidden by insulation
Whole house fanS A C N/A H
XNot working at time of inspection, covered
FlashingS A C N/A H
XLocations: Step flashing • Valleys • Vent pipes
Insulation ConditionS A C N/A H
XInsulation type: Blown fiberglass • Fiberglass battsThickness: 4" • 10"Recommend upgrade to R50 • Displaced insulation observed
VentilationS A C N/A H
XType: Gable louver • Ridge vent • Soffit venting
Environmental issuesS A C N/A H
XNone observed at time of inspection
Friendly Inspection Services Sample report
Page 25 of 26
Water penetrationS A C N/A H
XNone visible or accessible at time of inspection
Friendly Inspection Services Sample report
Page 26 of 26
Report SummaryReport Summary
RoofPage 2 Chimney • Some spalling brick observed • Cracks observed at back side of
chimney • Recommend increasing pitch of mortar cap and wash to bettershed water • Consult a mason contractor
Page 2 Gutters • Loose gutter nails at right side of garage
Exterior AreasPage 2 Eaves & Facia • Loose fascia observed at right side rake trim
Page 3 Siding Condition • Recommend sealing holes & gaps around wall penetrations withpolyurethane caulking
Page 3 Corner boards andtrim
• Rotted cupola
Page 4 Bulkhead / walkout • Damaged door latch, should be straightened to work properly
GaragePage 6 Garage doors &
opener • Too much down force at left door, needs adjustment • Electric eye safetysystem improperly installed • Electric eye units too high, manufacturersrecommend 6" from floor or less
Foundation / basementPage 8 Sump pump &
dehumidifier • None present
Page 8 Electrical • Missing electrical box cover
ElectricalPage 9 Service panel • Improper installation sub panel • Ground wire attached to neutral bus in
sub panel • Consult a licensed electricianLaundryPage 12 Floor Condition • Cracks observed in concrete floor
Family roomPage 22 Electrical • Hot & neutral reversed • Consult a licensed electrician
AtticPage 24 Electrical • Missing electrical box covers
Page 24 InsulationCondition
• Displaced insulation observed