Item Part # Description Wiring Item # FAN ASSEMBLIES, AND THERMOSTATS A. 12W Standard Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator 0461805 Fan Blade CONTROL PANEL B. lH59052001 Safe-NET ® III Display (2) C. EP.4483429 Safe-NET ® III Control (3) D. 0520584 Safe-NET ® III Discharge Sensor (4) E. 0520585 Safe-NET ® III Defrost Sensor (5) 1H16704003 Safe-NET ® III Display Harness REFRIGERATION F. 0516897 Condensate Pump (6) G. 0519269 Condensate Pan & Heater (7) (Evapoway) H. 0460992 TEV 2 Door Models 0460993 TEV 3-4-5 Door Models Item Part # Description Wiring Item # LED FIXTURES AND POWER SUPPLY I. 0499399 Power Supply (8) J. Door Lamp, LED BU.4440877 4100K Center (9) BU.4440878 4100K End (10) K Facade Lamp, LED (11) BU.4441411 2900K 29.5 In. Length BU.4441412 2900K 30.5 In. Length L. BU.4441414 Dry Goods Lamp, LED 3500K (12) KLU9600 Dry Goods Shelf, Lighted, Pearwood NOTE: For LED lighting parts contact your Hussmann service representative at 1-800-922-1919. Please have your model and serial number available. Descriptions including size and color are at WWW.HUSSMANN.COM/SERVICEANDPARTS. We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. OPTIONS SHOWN: Lighted Facades Dry Goods Storage Bump Out Partitions P/N_0520884_D ©2012 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-890-2900 • WWW.HUSSMANN.COM Refer to INNOVATOR REACH-IN GLASS DOOR INSTALLATION AND SERVICE manual, P/N 0425683, for Innovator and Innovator II door and frame replacement parts. ® Freedom Line RMN with INNOVATOR Doors or INNOVATOR III Doors Technical Data Sheet P/N 0520884_D NSF ® Certified December 2012 NOTE: Revision D revises electrical and MOPD, page 6. Other changes marked by bar, underline or circle. Warning: Terminal block NOT for case-to-case wire connection! Freedom Line merchandisers are top mount refrigeration ready

Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection

  • Upload
    vudang

  • View
    221

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection

Item Part # Description Wiring Item #

FAN ASSEMBLIES, AND THERMOSTATS

A. 12W Standard Energy Efficient Fan Assembly (1)0477655 Fan Motor, Evaporator0461805 Fan Blade

CONTROL PANEL

B. lH59052001 Safe-NET® III Display (2)C. EP.4483429 Safe-NET® III Control (3)D. 0520584 Safe-NET® III Discharge Sensor (4)E. 0520585 Safe-NET® III Defrost Sensor (5)

1H16704003 Safe-NET® III Display Harness

REFRIGERATION

F. 0516897 Condensate Pump (6)G. 0519269 Condensate Pan & Heater (7)

(Evapoway)H. 0460992 TEV 2 Door Models

0460993 TEV 3-4-5 Door Models

Item Part # Description Wiring Item #

LED FIXTURES AND POWER SUPPLY

I. 0499399 Power Supply (8)

J. Door Lamp, LED BU.4440877 4100K Center (9)BU.4440878 4100K End (10)

K Facade Lamp, LED (11)BU.4441411 2900K 29.5 In. Length BU.4441412 2900K 30.5 In. Length

L. BU.4441414 Dry Goods Lamp, LED 3500K (12)

KLU9600 Dry Goods Shelf, Lighted, Pearwood

NOTE: For LED lighting parts contact your Hussmann servicerepresentative at 1-800-922-1919. Please have your model andserial number available. Descriptions including size and colorare at WWW.HUSSMANN.COM/SERVICEANDPARTS.

We reserve the right to changeor revise specifications andproduct design in connectionwith any feature of our products. Such changes do not entitle the buyer to corresponding changes,improvements, additions orreplacements for equipmentpreviously sold or shipped.

OPTIONS SHOWN:

• Lighted Facades

• Dry Goods Storage

• Bump Out Partitions

P/N_0520884_D©2012 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-890-2900 • WWW.HUSSMANN.COM

Refer to INNOVATOR REACH-IN GLASS DOOR

INSTALLATION AND SERVICE manual, P/N 0425683, for Innovator and Innovator II door and framereplacement parts.

® Freedom Line RMNwith INNOVATOR Doors

or INNOVATOR III Doors

Technical Data Sheet

P/N 0520884_DNSF® Certified

December 2012

NOTE: Revision D revises electrical and MOPD, page 6. Other changes marked by bar, underline or circle.

Warning: Terminal block

NOT for case-to-case

wire connection!

Freedom Linemerchandisersare top mountrefrigeration

ready

Page 2: Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection

Freedom Line RMN with Innovator Doors Technical Data Sheet

2 of 13 U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900

Reach-In2, 3, 4 & 5 Door

EngineeringPlan Views

PHYSICAL DATAMerchandiser Drip Pipe (in.) 1 1/4Merchandiser Liquid Line (in.) 3/8Merchandiser Suction Line (in.) 7/8

Freedom LineRLN - RMN Plan View

05-2011

Base narrow footprint 5-door merchandiser is shown above, without Bump Out, Dry Goods, Partitions or Ends.

Illustrated below is a 4-door merchandiser with Dry Goods cabinets and Bump Out end partitions.

Refer to chart on Page 3 for detailed dimensional information on options.

Dimensions shown as inches and (mm).

Dimensions shown as inches and (mm).

Page 3: Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection

3 of 13P/N 0520884_D HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM

Freedom Line RMNWith Innovator Doors or Innovator III Doors

Medium Temperature

Plan View Dimensions for Freedom Line Options

Abbreviations: DG = Dry Goods section BO = Bump Out

2 Dr 3 Dr 4 Dr 5 Dr

General

(A) Merchandiser Length 62 (1575) 92 1/2 (2350) 122 7/8 (3121) 153 3/8 (3896)

(A) Merchandiser Length BO includes 2 bump-out ends 66 (1676) 96 1/2 (2451) 126 7/8 (3222) 157 3/8 (3997)

(A) Merchandiser Length DG includes 4 ends and dry goods cabinets 92 1/2 (2350) 123 (3124) 153 3/8 (3896) NA

Maximum O/S dimension of merchandiser back to front *** 39 3/4 (1010) 39 3/4 (1010) 39 3/4 (1010) 39 3/4 (1010)

Maximum O/S dimension of merchandiser back to front BO *** 51 3/4 (1314) 51 3/4 (1314) 51 3/4 (1314) 51 3/4 (1314)

*** Includes bumper. Add 26 1/2 in. (673 mm) for door swing.

Interior width of dry goods cabinet 10 3/4 (273) 10 3/4 (273) 10 3/4 (273) NA

Interior depth of dry goods cabinet 12 7/8 (327) 12 7/8 (327) 12 7/8 (327) NA

Back of merchandiser to rear of splashguard 35 7/8 (911) 35 7/8 (911) 35 7/8 (911) 35 7/8 (911)

Back of merchandiser to rear of splashguard BO 47 7/8 (1216) 47 7/8 (1216) 47 7/8 (1216) 47 7/8 (1216)

Width of Skid rail 3 3/4 (95) 3 3/4 (95) 3 3/4 (95) 3 3/4 (95)

Width of Bottom Front Support 6 (152) 6 (152) 6 (152) 6 (152)

Stub-up area between front support and splashguard 3 1/8 (79) 3 1/8 (79) 3 1/8 (79) 3 1/8 (79)

Electrical Service

(B) RH end of merchandiser to the center of nearest electrical service area 4 (102) 4 (102) 4 (102) 4 (102)

(B) RH end of merchandiser to the center of nearest electrical service area BO 6 (152) 6 (152) 6 (152) 6 (152)

(B) RH end of merchandiser to the center of nearest electrical service area DG 19 1/4 (489) 19 1/4 (489) 19 1/4 (489) NA

Back O/S of merchandiser with bump-out to center of electrical service area 49 5/8 (1260) 49 5/8 (1260) 49 5/8 (1260) 49 5/8 (1260)

* NOTE: Electrical Field Wiring Connection Point is at top.

Waste Outlet

(C) Right end of merchandiser to center of waste outlet 23 7/8 (606) 54 1/4 (1378) 46 1/4 (1175) 76 5/8 (1946)

(C) Right end of merchandiser to center of waste outlet BO 25 7/8 (657) 56 1/4 (1429) 48 1/4 (1226) 78 5/8 (1997)

(C) Right end of merchandiser to center of waste outlet DG 39 (991) 69 1/2 (1765) 61 1/2 (1562) NA

Back O/S of merchandiser with bump-out to center of waste outlet 42 5/8 (1083) 42 5/8 (1083) 42 5/8 (1083) 42 5/8 (1083)

Water Seal

Edge of water seal to center of waste outlet 13 (330) 13 (330) 13 (330) 13 (330)

Schedule 40 PVC drip pipe 1 1/4 (32) 1 1/4 (32) 1 1/4 (32) 1 1/4 (32)

** NOTE: Field installed water seal outlets, tees, and connectors are shipped with merchandiser.

Refrigeration Interface

(D) RH end of merchandiser to center of refrigeration interface 5 3/8 (136) 5 3/8 (136) 5 3/8 (136) 5 3/8 (136)

(D) RH end of merchandiser to center of refrigeration interface BO 7 3/8 (187) 7 3/8 (187) 7 3/8 (187) 7 3/8 (187)

(D) RH end of merchandiser to center of refrigeration interface DG 20 5/8 (524) 20 5/8 (524) 20 5/8 (524) NA

Back O/S of merchandiser with bump-out to center of refrigeration interface 44 (1118) 44 (1118) 44 (1118) 44 (1118)

* NOTE: Refrigeration Interface point is at top.

Outside bottom front supports from end of merchandiser 7 (178) 7 (178) 7 (178) 7 (178)

Outside bottom front supports from end of merchandiser BO 9 (229) 9 (229) 9 (229) 9 (229)

Outside bottom front supports from end of merchandiser DG 26 1/2 (673) 26 3/4 (679) RH 24 (610) 24 (610)

37 1/2 (952) LH

Center bottom front support from Centerline 24 (610) 24 (610) 24 (610) 24 (610)

Center bottom front support from Centerline BO 24 (610) 24 (610) 24 (610) 24 (610)

Center bottom front support from Centerline DG 6 3/4 (171) LH 8 3/4 (222) RH 24 (610) NA

Distance between Center and Outside supports will vary

(E) Depth when disassembled for door entry 35 1/2 (902) 35 1/2 (902) 35 1/2 (902) 35 1/2 (902)

Page 4: Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection

Freedom Line RMN with Innovator Doors Technical Data Sheet

4 of 13 U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900

Facade Cross Section

Partition and End ProfilesDry Goods Cross-Section

Freedom Line RMNWith Innovator Doors or Innovator III Doors

Medium Temperature

Page 5: Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection

REFRIGERATION DATA

Note: This data is based on store temperatureand humidity levels that do not exceed NSFguidelines.

MEDIUM TEMP

Discharge Air °F 32

DEFROST DATAFrequency (hr) 24Defrost Water (lb/Dr/day) 0.36(± 15% based on case configuration and productloading.)

OFFTIME 60 minutes

CONVENTIONAL CONTROLSCut In Cut Out

HPC (psig) 320 395

LPC (psig) 15 5

Working charge with recommendedCondensing Unit installed:

2Dr 2.3 lb 37 oz 1.0 kg3Dr 3.2 lb 51 oz 1.5 kg4Dr 3.7 lb 59 oz 1.7 kg5Dr 6.8 lb 109 oz 3.1 kg

Recommended Hussmann Condensing Unit:

Capacity Model2Dr 1000 Btu/hr TCMA3Dr 1500 Btu/hr TCMB4Dr 2000 Btu/hr TCMC5Dr 2500 Btu/hr TCMD

based on 27ºF (–2.8ºC) Evaporator temperature for low temperature applications.

Dimensions shown as inches and (mm).

Freedom Line Narrow Footprint Reach-inTop-Mount-Refrigeration Ready2, 3, 4 and 5 Door Models

5 of 13P/N 0520884_D HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM

NSF CertificationThis merchandiser model is manufactured to meet NSF/ANSI(National Sanitation Foundation) Standard #7 requirementsfor construction, materials & cleanability.

Freedom LineRLN - RMN

Hussmann refrigerated merchandisers configured for sale for use in the United States

meet or surpass the requirements of the DOE 2012 energy efficiency standards.

Freedom Line RMNWith Innovator Doors or Innovator III Doors

Medium Temperature

Note: Facade is field-installed.Electrical connection box,external supports, door handle and front racewaymay be removed to facilitate passage through door way.

Provide adequate clearance for air circulation at rear to reduce condensation.

Page 6: Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection

Electrical Data

2Dr 3Dr 4Dr 5Dr

Number of Fans—12W 2 3 4 5

Amperes Watts

Merchandiser 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr

120V Circuit

(Fans, anti-sweat heaters, drain pan heater, condensate pan heater, condensate pump, and standard Ecoshine 2 LED's)

With Innovator Doors (standard) 8.0 8.8 9.6 10.5 813 877 939 1003

Maximum Overcurrent

Protection Device (MOPD) 20 20 20 20

Refer to condensing unit data sheet for additional condensing unit electrical requirements.†

Standard Vertical LED Lighting 4100K 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr

Hussmann EcoShine II ™ [22 W] (120V) Included above)

Optional LED Lighting (24VDC)

Facade Lamps 0.79 1.17 1.54 1.92 19 28 37 46

Dry Goods Lamps (both sides, 10 per side) 1.50 1.50 1.50 NA* 36 36 36 NA*

* Dry Goods sections are not available on 5-Door models.

† Notes:

1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection for

the RMN and one 208/230V or 120Vconnection for the condensing unit.

2. The condensing unit amps must be used to calculate the total electrical load. Refer to the condensing unit data sheet.

3. Without heated condensate pan and pump, subtract 2.4 Amps

Freedom Line RMN with Innovator Doors Technical Data Sheet

6 of 13 U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900

Freedom Line RMNWith Innovator Doors or Innovator III Doors

Medium Temperature

Hussmann recommends against frame heater cyclingwith Innovator doors or Innovator III doors to preventdoor seals from freezing to the frames and tearing.

Page 7: Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection

7 of 13P/N 0520884_D HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM

Product Data

Recommended Usable Cube 1 (Cu Ft/Dr) 22.80 ft3 /Dr (0.65 m3 /Dr)AHRI Total Display Area 2 (Sq Ft/Dr) 13.31 ft2 /Dr (1.24 m2 /Dr)Shelf Area 3 (Sq Ft/Dr) 28.50 ft2 /Dr (2.65 m2 /Dr)

1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft3/ft [m3/m]2 Computed using AHRI 1200 standard methodology: Total Display Area, ft2 [m2]/Unit of Length, ft [m]3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann

Product Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch shelves.

Product Data (Dry Goods Area Only)

TOTAL Gross Usable Cube (Volume for 2 DG per merchandiser) 10.33 ft3 / (0.29 m3 )

ESTIMATED SHIPPING WEIGHT 4

2 Dr 3 Dr 4 Dr 5 Dr Solid End (each)

Standard Freedom Line Merchandiser (18-Inch Facade, no Arch)

lb (kg) 1005 (456) 1262 (572) 1688 (766) 2070 (939) 74 (34)

Freedom Line Merchandiser with Two (2) Bump Out Partitions (18-Inch Facade, no Arch)

lb (kg) 1185 (538) 1442 (654) 1868 (847) 2250 (1021) N/A

Freedom Line Merchandiser with Two (2) Dry Goods Sections, Four (4) Partitions (18-Inch Facade, no Arch)

lb (kg) 1481 (672) 1738 (788) 2164 (982) NA N/A

Freedom Line Merchandiser with

Two (2) Bump Out Partitions, Two (2) Dry Goods Sections, Two (2) Partitions (18-Inch Facade, no Arch)

lb (kg) 1522 (690) 1779 (807) 2205 (1000) NA N/A

4 Actual weights will vary according to optional kits included.

Freedom Line RMNWith Innovator Doors or Innovator III Doors

Medium Temperature

Page 8: Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection

Freedom Line RMN with Innovator Doors Technical Data Sheet

8 of 13 U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900

Page 9: Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection

9 of 13P/N 0520884_D HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM

Safe-NET™ Wiring Diagram — Medium Temperature Reach-in with 2 or 3 Doors

Freedom Line RMNWith Innovator Doors or Innovator III Doors

Medium Temperature

Page 10: Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection

Freedom Line RMN with Innovator Doors Technical Data Sheet

10 of 13 U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900

0520531 ASafe-NET™ Wiring Diagram — Medium Temperature Reach-in with 4 or 5 Doors

Freedom Line RMNWith Innovator Doors or Innovator III Doors

Medium Temperature

Page 11: Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection

11 of 13P/N 0520884_D HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM

Optional Lighting

LED Fixtures

Hussmann

EcoShine™

Freedom Line RMNWith Innovator Doors or Innovator III Doors

Medium Temperature

Page 12: Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection

Freedom Line RMN with Innovator Doors Technical Data Sheet

12 of 13 U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900

Optional Lighting Circuits

Freedom Line RMNWith Innovator Doors or Innovator III Doors

Medium Temperature

Page 13: Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection

13 of 13P/N 0520884_D HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM

Optional Lighting Circuits

Freedom Line RMNWith Innovator Doors or Innovator III Doors

Medium Temperature

Page 14: Freedom Line RMN - Bay Equipment Exchange PAGE/Hussman… · 1. Electrical input for the RMN Freedom cases require two electrical connections at the top of the case: one 120V connection