CIVIL ENVIRONMENTAL CONSULTANTS LLC ENGINEERS AND LAND SURVEYORS ----------------------------------------------------------------------- 8 Oak Street Peabody, MA 01960 Phone (978) 531-1191 Fax (978) 531-5501 [email protected] June 29, 2020 Boston Conservation Commission Boston City Hall I City Hall Square, Room 709 Boston, MA 02201-2031 Attn: Amelia Croteau Re: 874 East Sixth Street, So. Boston – DEP File No. 006-1699 Dear Ms. Croteau, On behalf of Cedarwood Development and East Sixth Street LLC, we are submitting revised Conservation Commission Site Plans which we believe addresses the Commission’s concerns regarding residential housing within the 100-yr floodplain, any concerns that ISD may have raised and ASCE Standard 24 for Flood Resistant Design and Construction.
• We have essentially eliminated the basement level of the building, save the elevator pit. • The parking, front access, rear exterior stair access, lobby, and elevator are all at ground floor
levels, with all floor levels (17.50 BCB) above the 100-yr floor level (17.46 BCB). The front door access is at elevation 18.0 (BCB).
• We have raised the garage floor and all the structures by to El. 17.5 BCB, which raises the slab and all structures above the high groundwater elevation. The driveway access to the garage has a high point of 18.44, which is almost 12 inches above the 100-yr flood elevation.
• We have raised the first floor to elevation 27.2 BCB. • We have left the grades of the rear yard unchanged from our last revision leaving the grade at
18.5’ BCB to match the neighbor’s grades and the average grade that previously existed. • With the above changes, the minimum grade height of the entry way, walls and driveway
surrounding the building is 18.0’ BCB which is 0.5’ above the 100-yr floodplain, effectively removing the building from the 100-yr floodplain.
• Because of the grade changes of the garage level, we were able to place the infiltrators under the garage slab and maintain proper separation to groundwater and hopefully satisfy the rear neighbor concerns regarding the infiltrators being too close to their property lines.
• We did add a single infiltrator under the driveway to pick up the stormwater from the entrance drive. We have surrounded that with 30 mil waterproof barriers to confine the infiltration to the immediate driveway area.
We have attached copies of the revised Conservation plans, revised architectural plans, revised Elevation Certificate and the revised Stormwater Management Report. Please call 978-290-1781 or e-mail me for any other information that you may need. We have also mailed two copies of all the above documents.
Very truly yours,
Frederick J. Geisel
Frederick J. Geisel, PE
STORMWATER MANAGEMENT REPORT – May 29,2020
874 EAST SIXTH ST. SO. BOSTON, MA
Background:
The property is located at 874 East sixth St. in South Boston, MA. This is a redevelopment site. The total area of property to be redeveloped consists of 6250 sq. ft. of land. The site previously contained a multi-family house. The project proponent proposes to construct a six-unit dwelling in a single structure. The project is a fullredevelopment of the site. Soil Conditions
The soils are classified as Merrimac Urban Land Complex. The soils are classified as Class A soils, for drainage purposes.
Flood Plain
The project site is within the Special Flood Hazard Areas designated by FEMA, for the 100-yr storm, with a flood elevation of AE-11.
Wetlands
The wetland resource areas of coastal bank and beach are approximately 350 feet from the site. The site contains approximately 500 sq. ft. of land subject to coastal storm flowage within the 100-yr flood zone.
Stormwater Management
As a redevelopment site, the project is required to meet Stormwater Standards to the maximum Extent Practicable. Roof and driveway ramp runoff is infiltrated by 2 infiltration Systems, The one system being a Single cultec 330xlhd(system 2 on the plan) in the driveway to gather and infiltrate the front side of the driveway's runoff, and the other system being10 Cultec 330xlhd Infiltrators(system 1 on the plan) both surrounded by crushed stone, which hold and infiltrate all design storms. Based on our analysis and design, the post- development flow rates and volume will be reduced from the pre-development flows for the analyzed frequency storms – 2-yr, 10-yr and 25-yr. & Flooding will not be increased for the 100-yr storm. All storm events will be infiltrated by the roof infiltrator systems with any overflow going to the Combined Sewer in East Sixth Street via a 6” sch40 pvc pipe. All Stormwater Management Standards will be met for the site.
All peak flows from the proposed roof areas will be attenuated by storage and infiltration through infiltration chambers that will store and infiltrate stormwater. These chambers will be as shown on the proposed site plan
Land in the rear will be landscaped with loam and grass, mulch, shrubs, and trees that will all serve to adsorb rainfall and reduce runoff.
Frederick J. Geisel, PE
Pre & Post Development Stormwater Flows
874 East Sixth StreetSouth Boston, MA
FREQ. EXISTING POST DEV. FLOW POST POSTSTORM FLOWS INTO INFILTRATION COMBINED INFIL. INFILTRATION
(CFS) SYSTEM 1 SYSTEM 2 OUTFLOW
1 Inch 0.0 0.21 0.01 0.22 0.0
2 YR 0.0 0.28 0.02 0.30 0.0
10 YR 0.07 0.48 0.04 0.52 0.0
25 YR 0.16 0.65 0.05 0.70 0.0
100 YR 0.41 0.98 0.07 1.05 0.41
2S
874 E 6th Building &
Rear Driveway
3P
10 CULTEC 330XLHD
Routing Diagram for 3793-874 east sixth-REV11-18-19Prepared by Civil Environmental Consultants LLC, Printed 5/21/2020HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Subcat Reach Pond Link
874 East Sixth Building & Rear Driveway
3793-874 east sixth-REV11-18-19 Printed 5/21/2020Prepared by Civil Environmental Consultants LLC
Page 2HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Project Notes
Rainfall events imported from "NRCS-Rain.txt" for 4035 MA Boston Suffolk County
874 East Sixth Building & Rear Driveway
3793-874 east sixth-REV11-18-19 Printed 5/21/2020Prepared by Civil Environmental Consultants LLC
Page 3HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Area Listing (selected nodes)
Area
(acres)
CN Description
(subcatchment-numbers)
0.029 39 >75% Grass cover, Good, HSG A (2S)
0.017 98 Paved parking, HSG A (2S)
0.091 98 Roofs, HSG A (2S)
0.137 86 TOTAL AREA
874 East Sixth Building & Rear Driveway
3793-874 east sixth-REV11-18-19 Printed 5/21/2020Prepared by Civil Environmental Consultants LLC
Page 4HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Soil Listing (selected nodes)
Area
(acres)
Soil
Group
Subcatchment
Numbers
0.137 HSG A 2S
0.000 HSG B
0.000 HSG C
0.000 HSG D
0.000 Other
0.137 TOTAL AREA
874 East Sixth Building & Rear Driveway
3793-874 east sixth-REV11-18-19 Printed 5/21/2020Prepared by Civil Environmental Consultants LLC
Page 5HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Ground Covers (selected nodes)
HSG-A
(acres)
HSG-B
(acres)
HSG-C
(acres)
HSG-D
(acres)
Other
(acres)
Total
(acres)
Ground
Cover
Subcatchment
Numbers
0.029 0.000 0.000 0.000 0.000 0.029 >75% Grass cover, Good 2S
0.017 0.000 0.000 0.000 0.000 0.017 Paved parking 2S
0.091 0.000 0.000 0.000 0.000 0.091 Roofs 2S
0.137 0.000 0.000 0.000 0.000 0.137 TOTAL AREA
874 East Sixth Building & Rear Driveway
3793-874 east sixth-REV11-18-19 Printed 5/21/2020Prepared by Civil Environmental Consultants LLC
Page 6HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pipe Listing (selected nodes)
Line# Node
Number
In-Invert
(feet)
Out-Invert
(feet)
Length
(feet)
Slope
(ft/ft)
n Diam/Width
(inches)
Height
(inches)
Inside-Fill
(inches)
1 3P 16.50 9.35 230.0 0.0311 0.010 6.0 0.0 0.0
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 2-Year Rainfall=3.26"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 7HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Time span=0.00-24.00 hrs, dt=0.05 hrs, 481 pointsRunoff by SCS TR-20 method, UH=SCS, Weighted-CN
Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method
Runoff Area=5,957 sf 79.10% Impervious Runoff Depth>1.88"Subcatchment 2S: 874 E 6th Building & Tc=6.0 min CN=86 Runoff=0.28 cfs 0.021 af
Peak Elev=14.19' Storage=129 cf Inflow=0.28 cfs 0.021 afPond 3P: 10 CULTEC 330XLHD Discarded=0.08 cfs 0.021 af Primary=0.00 cfs 0.000 af Outflow=0.08 cfs 0.021 af
Total Runoff Area = 0.137 ac Runoff Volume = 0.021 af Average Runoff Depth = 1.88"20.90% Pervious = 0.029 ac 79.10% Impervious = 0.108 ac
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 2-Year Rainfall=3.26"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 8HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Subcatchment 2S: 874 E 6th Building & Rear Driveway
Runoff = 0.28 cfs @ 12.13 hrs, Volume= 0.021 af, Depth> 1.88"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsNRCC 24-hr D 2-Year Rainfall=3.26"
Area (sf) CN Description
3,972 98 Roofs, HSG A740 98 Paved parking, HSG A
1,245 39 >75% Grass cover, Good, HSG A
5,957 86 Weighted Average1,245 20.90% Pervious Area4,712 79.10% Impervious Area
Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry, flow
Subcatchment 2S: 874 E 6th Building & Rear Driveway
Runoff
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.3
0.28
0.26
0.24
0.22
0.2
0.18
0.16
0.14
0.12
0.1
0.08
0.06
0.04
0.02
0
NRCC 24-hr D
2-Year Rainfall=3.26"
Runoff Area=5,957 sf
Runoff Volume=0.021 af
Runoff Depth>1.88"
Tc=6.0 min
CN=86
0.28 cfs
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 2-Year Rainfall=3.26"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 9HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Subcatchment 2S: 874 E 6th Building & Rear Driveway
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
0.00 0.00 0.00 0.000.25 0.01 0.00 0.000.50 0.02 0.00 0.000.75 0.04 0.00 0.001.00 0.05 0.00 0.001.25 0.06 0.00 0.001.50 0.07 0.00 0.001.75 0.09 0.00 0.002.00 0.10 0.00 0.002.25 0.11 0.00 0.002.50 0.12 0.00 0.002.75 0.14 0.00 0.003.00 0.15 0.00 0.003.25 0.17 0.00 0.003.50 0.18 0.00 0.003.75 0.20 0.00 0.004.00 0.21 0.00 0.004.25 0.23 0.00 0.004.50 0.24 0.00 0.004.75 0.26 0.00 0.005.00 0.27 0.00 0.005.25 0.29 0.00 0.005.50 0.30 0.00 0.005.75 0.32 0.00 0.006.00 0.34 0.00 0.006.25 0.35 0.00 0.006.50 0.37 0.00 0.006.75 0.39 0.00 0.007.00 0.41 0.00 0.007.25 0.43 0.01 0.007.50 0.45 0.01 0.007.75 0.47 0.01 0.008.00 0.50 0.02 0.008.25 0.52 0.02 0.008.50 0.55 0.03 0.008.75 0.57 0.03 0.009.00 0.60 0.04 0.009.25 0.63 0.05 0.009.50 0.66 0.06 0.019.75 0.69 0.07 0.01
10.00 0.73 0.08 0.0110.25 0.77 0.10 0.0110.50 0.81 0.11 0.0110.75 0.87 0.13 0.0111.00 0.93 0.16 0.0211.25 1.00 0.20 0.0211.50 1.09 0.25 0.0311.75 1.23 0.32 0.0412.00 1.56 0.53 0.1412.25 2.03 0.87 0.1312.50 2.17 0.98 0.06
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
12.75 2.26 1.05 0.0413.00 2.33 1.11 0.0313.25 2.39 1.16 0.0313.50 2.45 1.20 0.0213.75 2.49 1.23 0.0214.00 2.53 1.27 0.0214.25 2.57 1.30 0.0214.50 2.60 1.33 0.0214.75 2.63 1.35 0.0115.00 2.66 1.38 0.0115.25 2.69 1.40 0.0115.50 2.71 1.42 0.0115.75 2.74 1.44 0.0116.00 2.76 1.46 0.0116.25 2.79 1.48 0.0116.50 2.81 1.50 0.0116.75 2.83 1.52 0.0117.00 2.85 1.54 0.0117.25 2.87 1.55 0.0117.50 2.89 1.57 0.0117.75 2.91 1.58 0.0118.00 2.92 1.60 0.0118.25 2.94 1.61 0.0118.50 2.96 1.63 0.0118.75 2.97 1.64 0.0119.00 2.99 1.65 0.0119.25 3.00 1.67 0.0119.50 3.02 1.68 0.0119.75 3.03 1.69 0.0120.00 3.05 1.71 0.0120.25 3.06 1.72 0.0120.50 3.08 1.73 0.0120.75 3.09 1.74 0.0121.00 3.11 1.76 0.0121.25 3.12 1.77 0.0121.50 3.14 1.78 0.0121.75 3.15 1.79 0.0122.00 3.16 1.80 0.0122.25 3.17 1.81 0.0122.50 3.19 1.82 0.0122.75 3.20 1.84 0.0123.00 3.21 1.85 0.0123.25 3.22 1.86 0.0123.50 3.24 1.87 0.0123.75 3.25 1.88 0.0124.00 3.26 1.89 0.01
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 2-Year Rainfall=3.26"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 10HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Pond 3P: 10 CULTEC 330XLHD
Inflow Area = 0.137 ac, 79.10% Impervious, Inflow Depth > 1.88" for 2-Year eventInflow = 0.28 cfs @ 12.13 hrs, Volume= 0.021 afOutflow = 0.08 cfs @ 11.95 hrs, Volume= 0.021 af, Atten= 70%, Lag= 0.0 minDiscarded = 0.08 cfs @ 11.95 hrs, Volume= 0.021 afPrimary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsPeak Elev= 14.19' @ 12.34 hrs Surf.Area= 430 sf Storage= 129 cf
Plug-Flow detention time= 6.7 min calculated for 0.021 af (100% of inflow)Center-of-Mass det. time= 6.5 min ( 849.1 - 842.6 )
Volume Invert Avail.Storage Storage Description
#1A 13.50' 294 cf 11.17'W x 38.50'L x 3.54'H Field A1,523 cf Overall - 544 cf Embedded = 979 cf x 30.0% Voids
#2A 14.00' 544 cf Cultec R-330XLHD x 10 Inside #1Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cfOverall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' OverlapRow Length Adjustment= +1.50' x 7.45 sf x 2 rows
838 cf Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Discarded 13.50' 8.270 in/hr Exfiltration over Surface area #2 Primary 16.50' 6.0" Round Culvert L= 230.0' Ke= 0.500
Inlet / Outlet Invert= 16.50' / 9.35' S= 0.0311 '/' Cc= 0.900 n= 0.010 PVC, smooth interior, Flow Area= 0.20 sf
Discarded OutFlow Max=0.08 cfs @ 11.95 hrs HW=13.55' (Free Discharge)1=Exfiltration (Exfiltration Controls 0.08 cfs)
Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=13.50' (Free Discharge)2=Culvert ( Controls 0.00 cfs)
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 2-Year Rainfall=3.26"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 11HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 3P: 10 CULTEC 330XLHD - Chamber Wizard Field A
Chamber Model = Cultec R-330XLHD (Cultec Recharger® 330XLHD)
Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cf
Overall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' Overlap
Row Length Adjustment= +1.50' x 7.45 sf x 2 rows
52.0" Wide + 6.0" Spacing = 58.0" C-C Row Spacing
5 Chambers/Row x 7.00' Long +1.50' Row Adjustment = 36.50' Row Length +12.0" End Stone x 2 = 38.50'
Base Length
2 Rows x 52.0" Wide + 6.0" Spacing x 1 + 12.0" Side Stone x 2 = 11.17' Base Width
6.0" Base + 30.5" Chamber Height + 6.0" Cover = 3.54' Field Height
10 Chambers x 52.2 cf +1.50' Row Adjustment x 7.45 sf x 2 Rows = 543.9 cf Chamber Storage
1,522.6 cf Field - 543.9 cf Chambers = 978.7 cf Stone x 30.0% Voids = 293.6 cf Stone Storage
Chamber Storage + Stone Storage = 837.5 cf = 0.019 af
Overall Storage Efficiency = 55.0%
Overall System Size = 38.50' x 11.17' x 3.54'
10 Chambers
56.4 cy Field
36.2 cy Stone
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 2-Year Rainfall=3.26"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 12HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 3P: 10 CULTEC 330XLHD
InflowOutflowDiscardedPrimary
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.3
0.28
0.26
0.24
0.22
0.2
0.18
0.16
0.14
0.12
0.1
0.08
0.06
0.04
0.02
0
Inflow Area=0.137 ac
Peak Elev=14.19'
Storage=129 cf
0.28 cfs
0.08 cfs
0.08 cfs
0.00 cfs
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 2-Year Rainfall=3.26"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 13HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Pond 3P: 10 CULTEC 330XLHD
Time(hours)
Inflow(cfs)
Storage(cubic-feet)
Elevation(feet)
Outflow(cfs)
Discarded(cfs)
Primary(cfs)
0.00 0.00 0 13.50 0.00 0.00 0.000.50 0.00 0 13.50 0.00 0.00 0.001.00 0.00 0 13.50 0.00 0.00 0.001.50 0.00 0 13.50 0.00 0.00 0.002.00 0.00 0 13.50 0.00 0.00 0.002.50 0.00 0 13.50 0.00 0.00 0.003.00 0.00 0 13.50 0.00 0.00 0.003.50 0.00 0 13.50 0.00 0.00 0.004.00 0.00 0 13.50 0.00 0.00 0.004.50 0.00 0 13.50 0.00 0.00 0.005.00 0.00 0 13.50 0.00 0.00 0.005.50 0.00 0 13.50 0.00 0.00 0.006.00 0.00 0 13.50 0.00 0.00 0.006.50 0.00 0 13.50 0.00 0.00 0.007.00 0.00 0 13.50 0.00 0.00 0.007.50 0.00 0 13.50 0.00 0.00 0.008.00 0.00 0 13.50 0.00 0.00 0.008.50 0.00 0 13.50 0.00 0.00 0.009.00 0.00 0 13.50 0.00 0.00 0.009.50 0.01 0 13.50 0.01 0.01 0.00
10.00 0.01 0 13.50 0.01 0.01 0.0010.50 0.01 1 13.50 0.01 0.01 0.0011.00 0.02 1 13.51 0.02 0.02 0.0011.50 0.03 1 13.51 0.03 0.03 0.0012.00 0.14 12 13.60 0.08 0.08 0.0012.50 0.06 119 14.16 0.08 0.08 0.0013.00 0.03 43 13.84 0.08 0.08 0.0013.50 0.02 1 13.51 0.02 0.02 0.0014.00 0.02 1 13.51 0.02 0.02 0.0014.50 0.02 1 13.51 0.02 0.02 0.0015.00 0.01 1 13.51 0.01 0.01 0.0015.50 0.01 1 13.51 0.01 0.01 0.0016.00 0.01 1 13.50 0.01 0.01 0.0016.50 0.01 1 13.50 0.01 0.01 0.0017.00 0.01 1 13.50 0.01 0.01 0.0017.50 0.01 0 13.50 0.01 0.01 0.0018.00 0.01 0 13.50 0.01 0.01 0.0018.50 0.01 0 13.50 0.01 0.01 0.0019.00 0.01 0 13.50 0.01 0.01 0.0019.50 0.01 0 13.50 0.01 0.01 0.0020.00 0.01 0 13.50 0.01 0.01 0.0020.50 0.01 0 13.50 0.01 0.01 0.0021.00 0.01 0 13.50 0.01 0.01 0.0021.50 0.01 0 13.50 0.01 0.01 0.0022.00 0.01 0 13.50 0.01 0.01 0.0022.50 0.01 0 13.50 0.01 0.01 0.0023.00 0.01 0 13.50 0.01 0.01 0.0023.50 0.01 0 13.50 0.01 0.01 0.0024.00 0.01 0 13.50 0.01 0.01 0.00
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 10-Year Rainfall=4.90"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 14HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Time span=0.00-24.00 hrs, dt=0.05 hrs, 481 pointsRunoff by SCS TR-20 method, UH=SCS, Weighted-CN
Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method
Runoff Area=5,957 sf 79.10% Impervious Runoff Depth>3.37"Subcatchment 2S: 874 E 6th Building & Tc=6.0 min CN=86 Runoff=0.48 cfs 0.038 af
Peak Elev=14.90' Storage=355 cf Inflow=0.48 cfs 0.038 afPond 3P: 10 CULTEC 330XLHD Discarded=0.08 cfs 0.038 af Primary=0.00 cfs 0.000 af Outflow=0.08 cfs 0.038 af
Total Runoff Area = 0.137 ac Runoff Volume = 0.038 af Average Runoff Depth = 3.37"20.90% Pervious = 0.029 ac 79.10% Impervious = 0.108 ac
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 10-Year Rainfall=4.90"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 15HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Subcatchment 2S: 874 E 6th Building & Rear Driveway
Runoff = 0.48 cfs @ 12.13 hrs, Volume= 0.038 af, Depth> 3.37"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsNRCC 24-hr D 10-Year Rainfall=4.90"
Area (sf) CN Description
3,972 98 Roofs, HSG A740 98 Paved parking, HSG A
1,245 39 >75% Grass cover, Good, HSG A
5,957 86 Weighted Average1,245 20.90% Pervious Area4,712 79.10% Impervious Area
Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry, flow
Subcatchment 2S: 874 E 6th Building & Rear Driveway
Runoff
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
NRCC 24-hr D
10-Year Rainfall=4.90"
Runoff Area=5,957 sf
Runoff Volume=0.038 af
Runoff Depth>3.37"
Tc=6.0 min
CN=86
0.48 cfs
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 10-Year Rainfall=4.90"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 16HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Subcatchment 2S: 874 E 6th Building & Rear Driveway
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
0.00 0.00 0.00 0.000.25 0.02 0.00 0.000.50 0.04 0.00 0.000.75 0.05 0.00 0.001.00 0.07 0.00 0.001.25 0.09 0.00 0.001.50 0.11 0.00 0.001.75 0.13 0.00 0.002.00 0.15 0.00 0.002.25 0.17 0.00 0.002.50 0.19 0.00 0.002.75 0.21 0.00 0.003.00 0.23 0.00 0.003.25 0.25 0.00 0.003.50 0.27 0.00 0.003.75 0.29 0.00 0.004.00 0.32 0.00 0.004.25 0.34 0.00 0.004.50 0.36 0.00 0.004.75 0.38 0.00 0.005.00 0.41 0.00 0.005.25 0.43 0.01 0.005.50 0.46 0.01 0.005.75 0.48 0.01 0.006.00 0.50 0.02 0.006.25 0.53 0.02 0.006.50 0.56 0.03 0.006.75 0.59 0.04 0.007.00 0.62 0.04 0.007.25 0.65 0.05 0.017.50 0.68 0.06 0.017.75 0.71 0.07 0.018.00 0.75 0.09 0.018.25 0.78 0.10 0.018.50 0.82 0.12 0.018.75 0.86 0.13 0.019.00 0.90 0.15 0.019.25 0.94 0.17 0.019.50 0.99 0.19 0.019.75 1.04 0.22 0.01
10.00 1.10 0.25 0.0210.25 1.16 0.28 0.0210.50 1.22 0.32 0.0210.75 1.30 0.37 0.0311.00 1.39 0.42 0.0311.25 1.51 0.50 0.0411.50 1.64 0.59 0.0511.75 1.85 0.74 0.0812.00 2.35 1.12 0.2512.25 3.05 1.70 0.2212.50 3.26 1.89 0.09
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
12.75 3.39 2.01 0.0713.00 3.51 2.11 0.0513.25 3.60 2.19 0.0413.50 3.68 2.25 0.0413.75 3.74 2.31 0.0314.00 3.80 2.37 0.0314.25 3.86 2.42 0.0314.50 3.91 2.46 0.0314.75 3.96 2.51 0.0215.00 4.00 2.55 0.0215.25 4.04 2.58 0.0215.50 4.08 2.62 0.0215.75 4.12 2.65 0.0216.00 4.15 2.69 0.0216.25 4.19 2.72 0.0216.50 4.22 2.75 0.0216.75 4.25 2.78 0.0217.00 4.28 2.81 0.0217.25 4.31 2.83 0.0117.50 4.34 2.86 0.0117.75 4.37 2.88 0.0118.00 4.40 2.91 0.0118.25 4.42 2.93 0.0118.50 4.44 2.95 0.0118.75 4.47 2.97 0.0119.00 4.49 3.00 0.0119.25 4.52 3.02 0.0119.50 4.54 3.04 0.0119.75 4.56 3.06 0.0120.00 4.58 3.08 0.0120.25 4.61 3.10 0.0120.50 4.63 3.12 0.0120.75 4.65 3.14 0.0121.00 4.67 3.16 0.0121.25 4.69 3.18 0.0121.50 4.71 3.20 0.0121.75 4.73 3.22 0.0122.00 4.75 3.24 0.0122.25 4.77 3.25 0.0122.50 4.79 3.27 0.0122.75 4.81 3.29 0.0123.00 4.83 3.31 0.0123.25 4.85 3.32 0.0123.50 4.86 3.34 0.0123.75 4.88 3.36 0.0124.00 4.90 3.37 0.01
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 10-Year Rainfall=4.90"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 17HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Pond 3P: 10 CULTEC 330XLHD
Inflow Area = 0.137 ac, 79.10% Impervious, Inflow Depth > 3.37" for 10-Year eventInflow = 0.48 cfs @ 12.13 hrs, Volume= 0.038 afOutflow = 0.08 cfs @ 11.80 hrs, Volume= 0.038 af, Atten= 83%, Lag= 0.0 minDiscarded = 0.08 cfs @ 11.80 hrs, Volume= 0.038 afPrimary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsPeak Elev= 14.90' @ 12.58 hrs Surf.Area= 430 sf Storage= 355 cf
Plug-Flow detention time= 23.2 min calculated for 0.038 af (100% of inflow)Center-of-Mass det. time= 23.0 min ( 844.2 - 821.2 )
Volume Invert Avail.Storage Storage Description
#1A 13.50' 294 cf 11.17'W x 38.50'L x 3.54'H Field A1,523 cf Overall - 544 cf Embedded = 979 cf x 30.0% Voids
#2A 14.00' 544 cf Cultec R-330XLHD x 10 Inside #1Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cfOverall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' OverlapRow Length Adjustment= +1.50' x 7.45 sf x 2 rows
838 cf Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Discarded 13.50' 8.270 in/hr Exfiltration over Surface area #2 Primary 16.50' 6.0" Round Culvert L= 230.0' Ke= 0.500
Inlet / Outlet Invert= 16.50' / 9.35' S= 0.0311 '/' Cc= 0.900 n= 0.010 PVC, smooth interior, Flow Area= 0.20 sf
Discarded OutFlow Max=0.08 cfs @ 11.80 hrs HW=13.55' (Free Discharge)1=Exfiltration (Exfiltration Controls 0.08 cfs)
Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=13.50' (Free Discharge)2=Culvert ( Controls 0.00 cfs)
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 10-Year Rainfall=4.90"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 18HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 3P: 10 CULTEC 330XLHD - Chamber Wizard Field A
Chamber Model = Cultec R-330XLHD (Cultec Recharger® 330XLHD)
Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cf
Overall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' Overlap
Row Length Adjustment= +1.50' x 7.45 sf x 2 rows
52.0" Wide + 6.0" Spacing = 58.0" C-C Row Spacing
5 Chambers/Row x 7.00' Long +1.50' Row Adjustment = 36.50' Row Length +12.0" End Stone x 2 = 38.50'
Base Length
2 Rows x 52.0" Wide + 6.0" Spacing x 1 + 12.0" Side Stone x 2 = 11.17' Base Width
6.0" Base + 30.5" Chamber Height + 6.0" Cover = 3.54' Field Height
10 Chambers x 52.2 cf +1.50' Row Adjustment x 7.45 sf x 2 Rows = 543.9 cf Chamber Storage
1,522.6 cf Field - 543.9 cf Chambers = 978.7 cf Stone x 30.0% Voids = 293.6 cf Stone Storage
Chamber Storage + Stone Storage = 837.5 cf = 0.019 af
Overall Storage Efficiency = 55.0%
Overall System Size = 38.50' x 11.17' x 3.54'
10 Chambers
56.4 cy Field
36.2 cy Stone
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 10-Year Rainfall=4.90"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 19HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 3P: 10 CULTEC 330XLHD
InflowOutflowDiscardedPrimary
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
Inflow Area=0.137 ac
Peak Elev=14.90'
Storage=355 cf
0.48 cfs
0.08 cfs
0.08 cfs
0.00 cfs
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 10-Year Rainfall=4.90"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 20HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Pond 3P: 10 CULTEC 330XLHD
Time(hours)
Inflow(cfs)
Storage(cubic-feet)
Elevation(feet)
Outflow(cfs)
Discarded(cfs)
Primary(cfs)
0.00 0.00 0 13.50 0.00 0.00 0.000.50 0.00 0 13.50 0.00 0.00 0.001.00 0.00 0 13.50 0.00 0.00 0.001.50 0.00 0 13.50 0.00 0.00 0.002.00 0.00 0 13.50 0.00 0.00 0.002.50 0.00 0 13.50 0.00 0.00 0.003.00 0.00 0 13.50 0.00 0.00 0.003.50 0.00 0 13.50 0.00 0.00 0.004.00 0.00 0 13.50 0.00 0.00 0.004.50 0.00 0 13.50 0.00 0.00 0.005.00 0.00 0 13.50 0.00 0.00 0.005.50 0.00 0 13.50 0.00 0.00 0.006.00 0.00 0 13.50 0.00 0.00 0.006.50 0.00 0 13.50 0.00 0.00 0.007.00 0.00 0 13.50 0.00 0.00 0.007.50 0.01 0 13.50 0.01 0.01 0.008.00 0.01 0 13.50 0.01 0.01 0.008.50 0.01 0 13.50 0.01 0.01 0.009.00 0.01 1 13.50 0.01 0.01 0.009.50 0.01 1 13.51 0.01 0.01 0.00
10.00 0.02 1 13.51 0.02 0.02 0.0010.50 0.02 1 13.51 0.02 0.02 0.0011.00 0.03 2 13.51 0.03 0.03 0.0011.50 0.05 3 13.52 0.05 0.05 0.0012.00 0.25 58 13.95 0.08 0.08 0.0012.50 0.09 353 14.89 0.08 0.08 0.0013.00 0.05 327 14.81 0.08 0.08 0.0013.50 0.04 258 14.59 0.08 0.08 0.0014.00 0.03 168 14.31 0.08 0.08 0.0014.50 0.03 70 14.02 0.08 0.08 0.0015.00 0.02 1 13.51 0.02 0.02 0.0015.50 0.02 1 13.51 0.02 0.02 0.0016.00 0.02 1 13.51 0.02 0.02 0.0016.50 0.02 1 13.51 0.02 0.02 0.0017.00 0.02 1 13.51 0.02 0.02 0.0017.50 0.01 1 13.51 0.01 0.01 0.0018.00 0.01 1 13.51 0.01 0.01 0.0018.50 0.01 1 13.51 0.01 0.01 0.0019.00 0.01 1 13.51 0.01 0.01 0.0019.50 0.01 1 13.51 0.01 0.01 0.0020.00 0.01 1 13.50 0.01 0.01 0.0020.50 0.01 1 13.50 0.01 0.01 0.0021.00 0.01 1 13.50 0.01 0.01 0.0021.50 0.01 1 13.50 0.01 0.01 0.0022.00 0.01 1 13.50 0.01 0.01 0.0022.50 0.01 1 13.50 0.01 0.01 0.0023.00 0.01 1 13.50 0.01 0.01 0.0023.50 0.01 1 13.50 0.01 0.01 0.0024.00 0.01 1 13.50 0.01 0.01 0.00
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 25-Year Rainfall=6.19"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 21HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Time span=0.00-24.00 hrs, dt=0.05 hrs, 481 pointsRunoff by SCS TR-20 method, UH=SCS, Weighted-CN
Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method
Runoff Area=5,957 sf 79.10% Impervious Runoff Depth>4.58"Subcatchment 2S: 874 E 6th Building & Tc=6.0 min CN=86 Runoff=0.65 cfs 0.052 af
Peak Elev=15.64' Storage=578 cf Inflow=0.65 cfs 0.052 afPond 3P: 10 CULTEC 330XLHD Discarded=0.08 cfs 0.052 af Primary=0.00 cfs 0.000 af Outflow=0.08 cfs 0.052 af
Total Runoff Area = 0.137 ac Runoff Volume = 0.052 af Average Runoff Depth = 4.58"20.90% Pervious = 0.029 ac 79.10% Impervious = 0.108 ac
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 25-Year Rainfall=6.19"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 22HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Subcatchment 2S: 874 E 6th Building & Rear Driveway
Runoff = 0.65 cfs @ 12.13 hrs, Volume= 0.052 af, Depth> 4.58"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsNRCC 24-hr D 25-Year Rainfall=6.19"
Area (sf) CN Description
3,972 98 Roofs, HSG A740 98 Paved parking, HSG A
1,245 39 >75% Grass cover, Good, HSG A
5,957 86 Weighted Average1,245 20.90% Pervious Area4,712 79.10% Impervious Area
Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry, flow
Subcatchment 2S: 874 E 6th Building & Rear Driveway
Runoff
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.7
0.65
0.6
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
NRCC 24-hr D
25-Year Rainfall=6.19"
Runoff Area=5,957 sf
Runoff Volume=0.052 af
Runoff Depth>4.58"
Tc=6.0 min
CN=86
0.65 cfs
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 25-Year Rainfall=6.19"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 23HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Subcatchment 2S: 874 E 6th Building & Rear Driveway
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
0.00 0.00 0.00 0.000.25 0.02 0.00 0.000.50 0.04 0.00 0.000.75 0.07 0.00 0.001.00 0.09 0.00 0.001.25 0.11 0.00 0.001.50 0.14 0.00 0.001.75 0.16 0.00 0.002.00 0.19 0.00 0.002.25 0.21 0.00 0.002.50 0.24 0.00 0.002.75 0.26 0.00 0.003.00 0.29 0.00 0.003.25 0.32 0.00 0.003.50 0.34 0.00 0.003.75 0.37 0.00 0.004.00 0.40 0.00 0.004.25 0.43 0.01 0.004.50 0.46 0.01 0.004.75 0.49 0.01 0.005.00 0.51 0.02 0.005.25 0.54 0.03 0.005.50 0.58 0.03 0.005.75 0.61 0.04 0.006.00 0.64 0.05 0.006.25 0.67 0.06 0.016.50 0.70 0.07 0.016.75 0.74 0.08 0.017.00 0.78 0.10 0.017.25 0.82 0.11 0.017.50 0.86 0.13 0.017.75 0.90 0.15 0.018.00 0.94 0.17 0.018.25 0.99 0.19 0.018.50 1.04 0.22 0.018.75 1.09 0.24 0.019.00 1.14 0.27 0.029.25 1.19 0.30 0.029.50 1.25 0.34 0.029.75 1.32 0.38 0.02
10.00 1.39 0.42 0.0210.25 1.46 0.47 0.0310.50 1.55 0.52 0.0310.75 1.64 0.59 0.0411.00 1.76 0.67 0.0511.25 1.90 0.78 0.0611.50 2.07 0.91 0.0711.75 2.34 1.11 0.1212.00 2.97 1.63 0.3412.25 3.85 2.41 0.2912.50 4.12 2.65 0.12
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
12.75 4.29 2.81 0.0913.00 4.43 2.94 0.0713.25 4.55 3.05 0.0613.50 4.64 3.14 0.0513.75 4.73 3.21 0.0414.00 4.80 3.28 0.0414.25 4.87 3.35 0.0414.50 4.94 3.41 0.0314.75 5.00 3.47 0.0315.00 5.05 3.52 0.0315.25 5.10 3.56 0.0315.50 5.15 3.61 0.0315.75 5.20 3.65 0.0216.00 5.25 3.70 0.0216.25 5.29 3.74 0.0216.50 5.33 3.78 0.0216.75 5.37 3.82 0.0217.00 5.41 3.85 0.0217.25 5.45 3.89 0.0217.50 5.49 3.92 0.0217.75 5.52 3.95 0.0218.00 5.55 3.99 0.0218.25 5.58 4.02 0.0218.50 5.61 4.04 0.0218.75 5.65 4.07 0.0219.00 5.68 4.10 0.0219.25 5.70 4.13 0.0219.50 5.73 4.16 0.0219.75 5.76 4.18 0.0220.00 5.79 4.21 0.0120.25 5.82 4.24 0.0120.50 5.85 4.26 0.0120.75 5.87 4.29 0.0121.00 5.90 4.31 0.0121.25 5.93 4.34 0.0121.50 5.95 4.36 0.0121.75 5.98 4.39 0.0122.00 6.00 4.41 0.0122.25 6.03 4.44 0.0122.50 6.05 4.46 0.0122.75 6.08 4.48 0.0123.00 6.10 4.50 0.0123.25 6.12 4.53 0.0123.50 6.15 4.55 0.0123.75 6.17 4.57 0.0124.00 6.19 4.59 0.01
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 25-Year Rainfall=6.19"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 24HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Pond 3P: 10 CULTEC 330XLHD
Inflow Area = 0.137 ac, 79.10% Impervious, Inflow Depth > 4.58" for 25-Year eventInflow = 0.65 cfs @ 12.13 hrs, Volume= 0.052 afOutflow = 0.08 cfs @ 11.60 hrs, Volume= 0.052 af, Atten= 87%, Lag= 0.0 minDiscarded = 0.08 cfs @ 11.60 hrs, Volume= 0.052 afPrimary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsPeak Elev= 15.64' @ 12.80 hrs Surf.Area= 430 sf Storage= 578 cf
Plug-Flow detention time= 42.6 min calculated for 0.052 af (100% of inflow)Center-of-Mass det. time= 42.4 min ( 852.5 - 810.1 )
Volume Invert Avail.Storage Storage Description
#1A 13.50' 294 cf 11.17'W x 38.50'L x 3.54'H Field A1,523 cf Overall - 544 cf Embedded = 979 cf x 30.0% Voids
#2A 14.00' 544 cf Cultec R-330XLHD x 10 Inside #1Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cfOverall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' OverlapRow Length Adjustment= +1.50' x 7.45 sf x 2 rows
838 cf Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Discarded 13.50' 8.270 in/hr Exfiltration over Surface area #2 Primary 16.50' 6.0" Round Culvert L= 230.0' Ke= 0.500
Inlet / Outlet Invert= 16.50' / 9.35' S= 0.0311 '/' Cc= 0.900 n= 0.010 PVC, smooth interior, Flow Area= 0.20 sf
Discarded OutFlow Max=0.08 cfs @ 11.60 hrs HW=13.54' (Free Discharge)1=Exfiltration (Exfiltration Controls 0.08 cfs)
Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=13.50' (Free Discharge)2=Culvert ( Controls 0.00 cfs)
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 25-Year Rainfall=6.19"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 25HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 3P: 10 CULTEC 330XLHD - Chamber Wizard Field A
Chamber Model = Cultec R-330XLHD (Cultec Recharger® 330XLHD)
Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cf
Overall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' Overlap
Row Length Adjustment= +1.50' x 7.45 sf x 2 rows
52.0" Wide + 6.0" Spacing = 58.0" C-C Row Spacing
5 Chambers/Row x 7.00' Long +1.50' Row Adjustment = 36.50' Row Length +12.0" End Stone x 2 = 38.50'
Base Length
2 Rows x 52.0" Wide + 6.0" Spacing x 1 + 12.0" Side Stone x 2 = 11.17' Base Width
6.0" Base + 30.5" Chamber Height + 6.0" Cover = 3.54' Field Height
10 Chambers x 52.2 cf +1.50' Row Adjustment x 7.45 sf x 2 Rows = 543.9 cf Chamber Storage
1,522.6 cf Field - 543.9 cf Chambers = 978.7 cf Stone x 30.0% Voids = 293.6 cf Stone Storage
Chamber Storage + Stone Storage = 837.5 cf = 0.019 af
Overall Storage Efficiency = 55.0%
Overall System Size = 38.50' x 11.17' x 3.54'
10 Chambers
56.4 cy Field
36.2 cy Stone
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 25-Year Rainfall=6.19"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 26HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 3P: 10 CULTEC 330XLHD
InflowOutflowDiscardedPrimary
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.7
0.65
0.6
0.55
0.5
0.45
0.4
0.35
0.3
0.25
0.2
0.15
0.1
0.05
0
Inflow Area=0.137 ac
Peak Elev=15.64'
Storage=578 cf
0.65 cfs
0.08 cfs
0.08 cfs
0.00 cfs
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 25-Year Rainfall=6.19"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 27HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Pond 3P: 10 CULTEC 330XLHD
Time(hours)
Inflow(cfs)
Storage(cubic-feet)
Elevation(feet)
Outflow(cfs)
Discarded(cfs)
Primary(cfs)
0.00 0.00 0 13.50 0.00 0.00 0.000.50 0.00 0 13.50 0.00 0.00 0.001.00 0.00 0 13.50 0.00 0.00 0.001.50 0.00 0 13.50 0.00 0.00 0.002.00 0.00 0 13.50 0.00 0.00 0.002.50 0.00 0 13.50 0.00 0.00 0.003.00 0.00 0 13.50 0.00 0.00 0.003.50 0.00 0 13.50 0.00 0.00 0.004.00 0.00 0 13.50 0.00 0.00 0.004.50 0.00 0 13.50 0.00 0.00 0.005.00 0.00 0 13.50 0.00 0.00 0.005.50 0.00 0 13.50 0.00 0.00 0.006.00 0.00 0 13.50 0.00 0.00 0.006.50 0.01 0 13.50 0.01 0.01 0.007.00 0.01 0 13.50 0.01 0.01 0.007.50 0.01 1 13.50 0.01 0.01 0.008.00 0.01 1 13.50 0.01 0.01 0.008.50 0.01 1 13.51 0.01 0.01 0.009.00 0.02 1 13.51 0.02 0.02 0.009.50 0.02 1 13.51 0.02 0.02 0.00
10.00 0.02 1 13.51 0.02 0.02 0.0010.50 0.03 2 13.51 0.03 0.03 0.0011.00 0.05 3 13.52 0.05 0.05 0.0011.50 0.07 4 13.53 0.07 0.07 0.0012.00 0.34 117 14.16 0.08 0.08 0.0012.50 0.12 561 15.58 0.08 0.08 0.0013.00 0.07 574 15.62 0.08 0.08 0.0013.50 0.05 530 15.47 0.08 0.08 0.0014.00 0.04 458 15.22 0.08 0.08 0.0014.50 0.03 374 14.96 0.08 0.08 0.0015.00 0.03 281 14.66 0.08 0.08 0.0015.50 0.03 180 14.35 0.08 0.08 0.0016.00 0.02 76 14.03 0.08 0.08 0.0016.50 0.02 1 13.51 0.02 0.02 0.0017.00 0.02 1 13.51 0.02 0.02 0.0017.50 0.02 1 13.51 0.02 0.02 0.0018.00 0.02 1 13.51 0.02 0.02 0.0018.50 0.02 1 13.51 0.02 0.02 0.0019.00 0.02 1 13.51 0.02 0.02 0.0019.50 0.02 1 13.51 0.02 0.02 0.0020.00 0.01 1 13.51 0.01 0.01 0.0020.50 0.01 1 13.51 0.01 0.01 0.0021.00 0.01 1 13.51 0.01 0.01 0.0021.50 0.01 1 13.51 0.01 0.01 0.0022.00 0.01 1 13.51 0.01 0.01 0.0022.50 0.01 1 13.51 0.01 0.01 0.0023.00 0.01 1 13.51 0.01 0.01 0.0023.50 0.01 1 13.51 0.01 0.01 0.0024.00 0.01 1 13.51 0.01 0.01 0.00
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 100-Year Rainfall=8.83"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 28HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Time span=0.00-24.00 hrs, dt=0.05 hrs, 481 pointsRunoff by SCS TR-20 method, UH=SCS, Weighted-CN
Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method
Runoff Area=5,957 sf 79.10% Impervious Runoff Depth>7.13"Subcatchment 2S: 874 E 6th Building & Tc=6.0 min CN=86 Runoff=0.98 cfs 0.081 af
Peak Elev=16.95' Storage=826 cf Inflow=0.98 cfs 0.081 afPond 3P: 10 CULTEC 330XLHD Discarded=0.08 cfs 0.073 af Primary=0.43 cfs 0.008 af Outflow=0.51 cfs 0.081 af
Total Runoff Area = 0.137 ac Runoff Volume = 0.081 af Average Runoff Depth = 7.13"20.90% Pervious = 0.029 ac 79.10% Impervious = 0.108 ac
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 100-Year Rainfall=8.83"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 29HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Subcatchment 2S: 874 E 6th Building & Rear Driveway
Runoff = 0.98 cfs @ 12.13 hrs, Volume= 0.081 af, Depth> 7.13"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsNRCC 24-hr D 100-Year Rainfall=8.83"
Area (sf) CN Description
3,972 98 Roofs, HSG A740 98 Paved parking, HSG A
1,245 39 >75% Grass cover, Good, HSG A
5,957 86 Weighted Average1,245 20.90% Pervious Area4,712 79.10% Impervious Area
Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry, flow
Subcatchment 2S: 874 E 6th Building & Rear Driveway
Runoff
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
1
0
NRCC 24-hr D
100-Year Rainfall=8.83"
Runoff Area=5,957 sf
Runoff Volume=0.081 af
Runoff Depth>7.13"
Tc=6.0 min
CN=86
0.98 cfs
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 100-Year Rainfall=8.83"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 30HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Subcatchment 2S: 874 E 6th Building & Rear Driveway
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
0.00 0.00 0.00 0.000.25 0.03 0.00 0.000.50 0.06 0.00 0.000.75 0.10 0.00 0.001.00 0.13 0.00 0.001.25 0.16 0.00 0.001.50 0.20 0.00 0.001.75 0.23 0.00 0.002.00 0.27 0.00 0.002.25 0.30 0.00 0.002.50 0.34 0.00 0.002.75 0.38 0.00 0.003.00 0.41 0.00 0.003.25 0.45 0.01 0.003.50 0.49 0.02 0.003.75 0.53 0.02 0.004.00 0.57 0.03 0.014.25 0.61 0.04 0.014.50 0.65 0.05 0.014.75 0.69 0.07 0.015.00 0.73 0.08 0.015.25 0.78 0.10 0.015.50 0.82 0.12 0.015.75 0.86 0.13 0.016.00 0.91 0.15 0.016.25 0.96 0.18 0.016.50 1.00 0.20 0.016.75 1.06 0.23 0.017.00 1.11 0.25 0.027.25 1.16 0.29 0.027.50 1.22 0.32 0.027.75 1.28 0.35 0.028.00 1.35 0.39 0.028.25 1.41 0.43 0.028.50 1.48 0.48 0.028.75 1.55 0.52 0.039.00 1.62 0.57 0.039.25 1.70 0.63 0.039.50 1.78 0.69 0.039.75 1.88 0.76 0.04
10.00 1.98 0.83 0.0410.25 2.09 0.92 0.0510.50 2.21 1.01 0.0510.75 2.34 1.12 0.0611.00 2.51 1.25 0.0811.25 2.71 1.42 0.1011.50 2.96 1.63 0.1211.75 3.34 1.95 0.1812.00 4.23 2.76 0.5312.25 5.49 3.93 0.4312.50 5.87 4.29 0.18
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
12.75 6.12 4.52 0.1313.00 6.32 4.72 0.1013.25 6.49 4.87 0.0913.50 6.62 5.01 0.0713.75 6.74 5.12 0.0614.00 6.85 5.22 0.0614.25 6.95 5.32 0.0514.50 7.05 5.41 0.0514.75 7.13 5.49 0.0515.00 7.21 5.57 0.0415.25 7.28 5.64 0.0415.50 7.35 5.70 0.0415.75 7.42 5.77 0.0416.00 7.48 5.83 0.0316.25 7.55 5.89 0.0316.50 7.61 5.95 0.0316.75 7.67 6.01 0.0317.00 7.72 6.06 0.0317.25 7.77 6.11 0.0317.50 7.83 6.16 0.0317.75 7.87 6.21 0.0318.00 7.92 6.25 0.0218.25 7.97 6.30 0.0218.50 8.01 6.34 0.0218.75 8.05 6.38 0.0219.00 8.10 6.42 0.0219.25 8.14 6.46 0.0219.50 8.18 6.51 0.0219.75 8.22 6.55 0.0220.00 8.26 6.58 0.0220.25 8.30 6.62 0.0220.50 8.34 6.66 0.0220.75 8.38 6.70 0.0221.00 8.42 6.74 0.0221.25 8.45 6.77 0.0221.50 8.49 6.81 0.0221.75 8.53 6.84 0.0222.00 8.56 6.88 0.0222.25 8.60 6.91 0.0222.50 8.63 6.95 0.0222.75 8.67 6.98 0.0223.00 8.70 7.01 0.0223.25 8.73 7.04 0.0223.50 8.77 7.08 0.0223.75 8.80 7.11 0.0224.00 8.83 7.14 0.02
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 100-Year Rainfall=8.83"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 31HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Pond 3P: 10 CULTEC 330XLHD
Inflow Area = 0.137 ac, 79.10% Impervious, Inflow Depth > 7.13" for 100-Year eventInflow = 0.98 cfs @ 12.13 hrs, Volume= 0.081 afOutflow = 0.51 cfs @ 12.26 hrs, Volume= 0.081 af, Atten= 48%, Lag= 8.1 minDiscarded = 0.08 cfs @ 11.15 hrs, Volume= 0.073 afPrimary = 0.43 cfs @ 12.26 hrs, Volume= 0.008 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsPeak Elev= 16.95' @ 12.26 hrs Surf.Area= 430 sf Storage= 826 cf
Plug-Flow detention time= 56.5 min calculated for 0.081 af (100% of inflow)Center-of-Mass det. time= 56.2 min ( 850.9 - 794.7 )
Volume Invert Avail.Storage Storage Description
#1A 13.50' 294 cf 11.17'W x 38.50'L x 3.54'H Field A1,523 cf Overall - 544 cf Embedded = 979 cf x 30.0% Voids
#2A 14.00' 544 cf Cultec R-330XLHD x 10 Inside #1Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cfOverall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' OverlapRow Length Adjustment= +1.50' x 7.45 sf x 2 rows
838 cf Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Discarded 13.50' 8.270 in/hr Exfiltration over Surface area #2 Primary 16.50' 6.0" Round Culvert L= 230.0' Ke= 0.500
Inlet / Outlet Invert= 16.50' / 9.35' S= 0.0311 '/' Cc= 0.900 n= 0.010 PVC, smooth interior, Flow Area= 0.20 sf
Discarded OutFlow Max=0.08 cfs @ 11.15 hrs HW=13.54' (Free Discharge)1=Exfiltration (Exfiltration Controls 0.08 cfs)
Primary OutFlow Max=0.39 cfs @ 12.26 hrs HW=16.92' (Free Discharge)2=Culvert (Inlet Controls 0.39 cfs @ 2.20 fps)
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 100-Year Rainfall=8.83"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 32HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 3P: 10 CULTEC 330XLHD - Chamber Wizard Field A
Chamber Model = Cultec R-330XLHD (Cultec Recharger® 330XLHD)
Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cf
Overall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' Overlap
Row Length Adjustment= +1.50' x 7.45 sf x 2 rows
52.0" Wide + 6.0" Spacing = 58.0" C-C Row Spacing
5 Chambers/Row x 7.00' Long +1.50' Row Adjustment = 36.50' Row Length +12.0" End Stone x 2 = 38.50'
Base Length
2 Rows x 52.0" Wide + 6.0" Spacing x 1 + 12.0" Side Stone x 2 = 11.17' Base Width
6.0" Base + 30.5" Chamber Height + 6.0" Cover = 3.54' Field Height
10 Chambers x 52.2 cf +1.50' Row Adjustment x 7.45 sf x 2 Rows = 543.9 cf Chamber Storage
1,522.6 cf Field - 543.9 cf Chambers = 978.7 cf Stone x 30.0% Voids = 293.6 cf Stone Storage
Chamber Storage + Stone Storage = 837.5 cf = 0.019 af
Overall Storage Efficiency = 55.0%
Overall System Size = 38.50' x 11.17' x 3.54'
10 Chambers
56.4 cy Field
36.2 cy Stone
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 100-Year Rainfall=8.83"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 33HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 3P: 10 CULTEC 330XLHD
InflowOutflowDiscardedPrimary
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
1
0
Inflow Area=0.137 ac
Peak Elev=16.95'
Storage=826 cf
0.98 cfs
0.51 cfs
0.08 cfs
0.43 cfs
874 East Sixth Building & Rear DrivewayNRCC 24-hr D 100-Year Rainfall=8.83"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 34HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Pond 3P: 10 CULTEC 330XLHD
Time(hours)
Inflow(cfs)
Storage(cubic-feet)
Elevation(feet)
Outflow(cfs)
Discarded(cfs)
Primary(cfs)
0.00 0.00 0 13.50 0.00 0.00 0.000.50 0.00 0 13.50 0.00 0.00 0.001.00 0.00 0 13.50 0.00 0.00 0.001.50 0.00 0 13.50 0.00 0.00 0.002.00 0.00 0 13.50 0.00 0.00 0.002.50 0.00 0 13.50 0.00 0.00 0.003.00 0.00 0 13.50 0.00 0.00 0.003.50 0.00 0 13.50 0.00 0.00 0.004.00 0.01 0 13.50 0.01 0.01 0.004.50 0.01 0 13.50 0.01 0.01 0.005.00 0.01 0 13.50 0.01 0.01 0.005.50 0.01 1 13.50 0.01 0.01 0.006.00 0.01 1 13.50 0.01 0.01 0.006.50 0.01 1 13.51 0.01 0.01 0.007.00 0.02 1 13.51 0.02 0.02 0.007.50 0.02 1 13.51 0.02 0.02 0.008.00 0.02 1 13.51 0.02 0.02 0.008.50 0.02 1 13.51 0.02 0.02 0.009.00 0.03 2 13.51 0.03 0.03 0.009.50 0.03 2 13.51 0.03 0.03 0.00
10.00 0.04 2 13.52 0.04 0.04 0.0010.50 0.05 3 13.52 0.05 0.05 0.0011.00 0.08 4 13.53 0.07 0.07 0.0011.50 0.12 30 13.73 0.08 0.08 0.0012.00 0.53 288 14.68 0.08 0.08 0.0012.50 0.18 793 16.70 0.19 0.08 0.1113.00 0.10 780 16.59 0.11 0.08 0.0313.50 0.07 767 16.50 0.08 0.08 0.0014.00 0.06 731 16.27 0.08 0.08 0.0014.50 0.05 678 16.02 0.08 0.08 0.0015.00 0.04 611 15.76 0.08 0.08 0.0015.50 0.04 533 15.48 0.08 0.08 0.0016.00 0.03 449 15.20 0.08 0.08 0.0016.50 0.03 361 14.91 0.08 0.08 0.0017.00 0.03 268 14.62 0.08 0.08 0.0017.50 0.03 171 14.32 0.08 0.08 0.0018.00 0.02 69 14.01 0.08 0.08 0.0018.50 0.02 1 13.51 0.02 0.02 0.0019.00 0.02 1 13.51 0.02 0.02 0.0019.50 0.02 1 13.51 0.02 0.02 0.0020.00 0.02 1 13.51 0.02 0.02 0.0020.50 0.02 1 13.51 0.02 0.02 0.0021.00 0.02 1 13.51 0.02 0.02 0.0021.50 0.02 1 13.51 0.02 0.02 0.0022.00 0.02 1 13.51 0.02 0.02 0.0022.50 0.02 1 13.51 0.02 0.02 0.0023.00 0.02 1 13.51 0.02 0.02 0.0023.50 0.02 1 13.51 0.02 0.02 0.0024.00 0.02 1 13.51 0.02 0.02 0.00
874 East Sixth Building & Rear DrivewayNRCC 24-hr D Custom Rainfall=1.00"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 35HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Time span=0.00-24.00 hrs, dt=0.05 hrs, 481 pointsRunoff by SCS TR-20 method, UH=SCS, Weighted-CN
Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method
Runoff Area=5,957 sf 79.10% Impervious Runoff Depth>0.20"Subcatchment 2S: 874 E 6th Building & Tc=6.0 min CN=86 Runoff=0.02 cfs 0.002 af
Peak Elev=13.51' Storage=1 cf Inflow=0.02 cfs 0.002 afPond 3P: 10 CULTEC 330XLHD Discarded=0.02 cfs 0.002 af Primary=0.00 cfs 0.000 af Outflow=0.02 cfs 0.002 af
Total Runoff Area = 0.137 ac Runoff Volume = 0.002 af Average Runoff Depth = 0.20"20.90% Pervious = 0.029 ac 79.10% Impervious = 0.108 ac
874 East Sixth Building & Rear DrivewayNRCC 24-hr D Custom Rainfall=1.00"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 36HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Subcatchment 2S: 874 E 6th Building & Rear Driveway
Runoff = 0.02 cfs @ 12.14 hrs, Volume= 0.002 af, Depth> 0.20"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsNRCC 24-hr D Custom Rainfall=1.00"
Area (sf) CN Description
3,972 98 Roofs, HSG A740 98 Paved parking, HSG A
1,245 39 >75% Grass cover, Good, HSG A
5,957 86 Weighted Average1,245 20.90% Pervious Area4,712 79.10% Impervious Area
Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry, flow
Subcatchment 2S: 874 E 6th Building & Rear Driveway
Runoff
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.026
0.024
0.022
0.02
0.018
0.016
0.014
0.012
0.01
0.008
0.006
0.004
0.002
0
NRCC 24-hr D
Custom Rainfall=1.00"
Runoff Area=5,957 sf
Runoff Volume=0.002 af
Runoff Depth>0.20"
Tc=6.0 min
CN=86
0.02 cfs
874 East Sixth Building & Rear DrivewayNRCC 24-hr D Custom Rainfall=1.00"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 37HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Subcatchment 2S: 874 E 6th Building & Rear Driveway
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
0.00 0.00 0.00 0.000.25 0.00 0.00 0.000.50 0.01 0.00 0.000.75 0.01 0.00 0.001.00 0.01 0.00 0.001.25 0.02 0.00 0.001.50 0.02 0.00 0.001.75 0.03 0.00 0.002.00 0.03 0.00 0.002.25 0.03 0.00 0.002.50 0.04 0.00 0.002.75 0.04 0.00 0.003.00 0.05 0.00 0.003.25 0.05 0.00 0.003.50 0.06 0.00 0.003.75 0.06 0.00 0.004.00 0.06 0.00 0.004.25 0.07 0.00 0.004.50 0.07 0.00 0.004.75 0.08 0.00 0.005.00 0.08 0.00 0.005.25 0.09 0.00 0.005.50 0.09 0.00 0.005.75 0.10 0.00 0.006.00 0.10 0.00 0.006.25 0.11 0.00 0.006.50 0.11 0.00 0.006.75 0.12 0.00 0.007.00 0.13 0.00 0.007.25 0.13 0.00 0.007.50 0.14 0.00 0.007.75 0.15 0.00 0.008.00 0.15 0.00 0.008.25 0.16 0.00 0.008.50 0.17 0.00 0.008.75 0.18 0.00 0.009.00 0.18 0.00 0.009.25 0.19 0.00 0.009.50 0.20 0.00 0.009.75 0.21 0.00 0.00
10.00 0.22 0.00 0.0010.25 0.24 0.00 0.0010.50 0.25 0.00 0.0010.75 0.27 0.00 0.0011.00 0.28 0.00 0.0011.25 0.31 0.00 0.0011.50 0.33 0.00 0.0011.75 0.38 0.00 0.0012.00 0.48 0.01 0.0112.25 0.62 0.05 0.0112.50 0.66 0.06 0.01
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
12.75 0.69 0.07 0.0013.00 0.72 0.08 0.0013.25 0.73 0.08 0.0013.50 0.75 0.09 0.0013.75 0.76 0.09 0.0014.00 0.78 0.10 0.0014.25 0.79 0.10 0.0014.50 0.80 0.11 0.0014.75 0.81 0.11 0.0015.00 0.82 0.11 0.0015.25 0.82 0.12 0.0015.50 0.83 0.12 0.0015.75 0.84 0.12 0.0016.00 0.85 0.13 0.0016.25 0.85 0.13 0.0016.50 0.86 0.13 0.0016.75 0.87 0.14 0.0017.00 0.87 0.14 0.0017.25 0.88 0.14 0.0017.50 0.89 0.14 0.0017.75 0.89 0.15 0.0018.00 0.90 0.15 0.0018.25 0.90 0.15 0.0018.50 0.91 0.15 0.0018.75 0.91 0.16 0.0019.00 0.92 0.16 0.0019.25 0.92 0.16 0.0019.50 0.93 0.16 0.0019.75 0.93 0.16 0.0020.00 0.94 0.17 0.0020.25 0.94 0.17 0.0020.50 0.94 0.17 0.0020.75 0.95 0.17 0.0021.00 0.95 0.17 0.0021.25 0.96 0.18 0.0021.50 0.96 0.18 0.0021.75 0.97 0.18 0.0022.00 0.97 0.18 0.0022.25 0.97 0.18 0.0022.50 0.98 0.19 0.0022.75 0.98 0.19 0.0023.00 0.99 0.19 0.0023.25 0.99 0.19 0.0023.50 0.99 0.19 0.0023.75 1.00 0.20 0.0024.00 1.00 0.20 0.00
874 East Sixth Building & Rear DrivewayNRCC 24-hr D Custom Rainfall=1.00"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 38HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Pond 3P: 10 CULTEC 330XLHD
Inflow Area = 0.137 ac, 79.10% Impervious, Inflow Depth > 0.20" for Custom eventInflow = 0.02 cfs @ 12.14 hrs, Volume= 0.002 afOutflow = 0.02 cfs @ 12.16 hrs, Volume= 0.002 af, Atten= 3%, Lag= 0.9 minDiscarded = 0.02 cfs @ 12.16 hrs, Volume= 0.002 afPrimary = 0.00 cfs @ 0.00 hrs, Volume= 0.000 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsPeak Elev= 13.51' @ 12.16 hrs Surf.Area= 430 sf Storage= 1 cf
Plug-Flow detention time= 0.9 min calculated for 0.002 af (100% of inflow)Center-of-Mass det. time= 0.6 min ( 931.3 - 930.6 )
Volume Invert Avail.Storage Storage Description
#1A 13.50' 294 cf 11.17'W x 38.50'L x 3.54'H Field A1,523 cf Overall - 544 cf Embedded = 979 cf x 30.0% Voids
#2A 14.00' 544 cf Cultec R-330XLHD x 10 Inside #1Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cfOverall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' OverlapRow Length Adjustment= +1.50' x 7.45 sf x 2 rows
838 cf Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Discarded 13.50' 8.270 in/hr Exfiltration over Surface area #2 Primary 16.50' 6.0" Round Culvert L= 230.0' Ke= 0.500
Inlet / Outlet Invert= 16.50' / 9.35' S= 0.0311 '/' Cc= 0.900 n= 0.010 PVC, smooth interior, Flow Area= 0.20 sf
Discarded OutFlow Max=0.08 cfs @ 12.16 hrs HW=13.51' (Free Discharge)1=Exfiltration (Exfiltration Controls 0.08 cfs)
Primary OutFlow Max=0.00 cfs @ 0.00 hrs HW=13.50' (Free Discharge)2=Culvert ( Controls 0.00 cfs)
874 East Sixth Building & Rear DrivewayNRCC 24-hr D Custom Rainfall=1.00"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 39HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 3P: 10 CULTEC 330XLHD - Chamber Wizard Field A
Chamber Model = Cultec R-330XLHD (Cultec Recharger® 330XLHD)
Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cf
Overall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' Overlap
Row Length Adjustment= +1.50' x 7.45 sf x 2 rows
52.0" Wide + 6.0" Spacing = 58.0" C-C Row Spacing
5 Chambers/Row x 7.00' Long +1.50' Row Adjustment = 36.50' Row Length +12.0" End Stone x 2 = 38.50'
Base Length
2 Rows x 52.0" Wide + 6.0" Spacing x 1 + 12.0" Side Stone x 2 = 11.17' Base Width
6.0" Base + 30.5" Chamber Height + 6.0" Cover = 3.54' Field Height
10 Chambers x 52.2 cf +1.50' Row Adjustment x 7.45 sf x 2 Rows = 543.9 cf Chamber Storage
1,522.6 cf Field - 543.9 cf Chambers = 978.7 cf Stone x 30.0% Voids = 293.6 cf Stone Storage
Chamber Storage + Stone Storage = 837.5 cf = 0.019 af
Overall Storage Efficiency = 55.0%
Overall System Size = 38.50' x 11.17' x 3.54'
10 Chambers
56.4 cy Field
36.2 cy Stone
874 East Sixth Building & Rear DrivewayNRCC 24-hr D Custom Rainfall=1.00"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 40HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 3P: 10 CULTEC 330XLHD
InflowOutflowDiscardedPrimary
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.026
0.024
0.022
0.02
0.018
0.016
0.014
0.012
0.01
0.008
0.006
0.004
0.002
0
Inflow Area=0.137 ac
Peak Elev=13.51'
Storage=1 cf
0.02 cfs
0.02 cfs
0.02 cfs
0.00 cfs
874 East Sixth Building & Rear DrivewayNRCC 24-hr D Custom Rainfall=1.00"3793-874 east sixth-REV11-18-19
Printed 5/21/2020Prepared by Civil Environmental Consultants LLCPage 41HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Pond 3P: 10 CULTEC 330XLHD
Time(hours)
Inflow(cfs)
Storage(cubic-feet)
Elevation(feet)
Outflow(cfs)
Discarded(cfs)
Primary(cfs)
0.00 0.00 0 13.50 0.00 0.00 0.000.50 0.00 0 13.50 0.00 0.00 0.001.00 0.00 0 13.50 0.00 0.00 0.001.50 0.00 0 13.50 0.00 0.00 0.002.00 0.00 0 13.50 0.00 0.00 0.002.50 0.00 0 13.50 0.00 0.00 0.003.00 0.00 0 13.50 0.00 0.00 0.003.50 0.00 0 13.50 0.00 0.00 0.004.00 0.00 0 13.50 0.00 0.00 0.004.50 0.00 0 13.50 0.00 0.00 0.005.00 0.00 0 13.50 0.00 0.00 0.005.50 0.00 0 13.50 0.00 0.00 0.006.00 0.00 0 13.50 0.00 0.00 0.006.50 0.00 0 13.50 0.00 0.00 0.007.00 0.00 0 13.50 0.00 0.00 0.007.50 0.00 0 13.50 0.00 0.00 0.008.00 0.00 0 13.50 0.00 0.00 0.008.50 0.00 0 13.50 0.00 0.00 0.009.00 0.00 0 13.50 0.00 0.00 0.009.50 0.00 0 13.50 0.00 0.00 0.00
10.00 0.00 0 13.50 0.00 0.00 0.0010.50 0.00 0 13.50 0.00 0.00 0.0011.00 0.00 0 13.50 0.00 0.00 0.0011.50 0.00 0 13.50 0.00 0.00 0.0012.00 0.01 0 13.50 0.01 0.01 0.0012.50 0.01 0 13.50 0.01 0.01 0.0013.00 0.00 0 13.50 0.00 0.00 0.0013.50 0.00 0 13.50 0.00 0.00 0.0014.00 0.00 0 13.50 0.00 0.00 0.0014.50 0.00 0 13.50 0.00 0.00 0.0015.00 0.00 0 13.50 0.00 0.00 0.0015.50 0.00 0 13.50 0.00 0.00 0.0016.00 0.00 0 13.50 0.00 0.00 0.0016.50 0.00 0 13.50 0.00 0.00 0.0017.00 0.00 0 13.50 0.00 0.00 0.0017.50 0.00 0 13.50 0.00 0.00 0.0018.00 0.00 0 13.50 0.00 0.00 0.0018.50 0.00 0 13.50 0.00 0.00 0.0019.00 0.00 0 13.50 0.00 0.00 0.0019.50 0.00 0 13.50 0.00 0.00 0.0020.00 0.00 0 13.50 0.00 0.00 0.0020.50 0.00 0 13.50 0.00 0.00 0.0021.00 0.00 0 13.50 0.00 0.00 0.0021.50 0.00 0 13.50 0.00 0.00 0.0022.00 0.00 0 13.50 0.00 0.00 0.0022.50 0.00 0 13.50 0.00 0.00 0.0023.00 0.00 0 13.50 0.00 0.00 0.0023.50 0.00 0 13.50 0.00 0.00 0.0024.00 0.00 0 13.50 0.00 0.00 0.00
4S
874 E 6th Entry
Driveway
5P
1 CULTEC 330XLHD
Routing Diagram for 3793-874 east sixth-REV11-18-19Prepared by Civil Environmental Consultants LLC, Printed 5/22/2020HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Subcat Reach Pond Link
874 East Sixth Building entry Driveway
3793-874 east sixth-REV11-18-19 Printed 5/22/2020Prepared by Civil Environmental Consultants LLC
Page 2HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Project Notes
Rainfall events imported from "NRCS-Rain.txt" for 4035 MA Boston Suffolk County
874 East Sixth Building entry Driveway
3793-874 east sixth-REV11-18-19 Printed 5/22/2020Prepared by Civil Environmental Consultants LLC
Page 3HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Area Listing (selected nodes)
Area
(acres)
CN Description
(subcatchment-numbers)
0.009 98 Paved parking, HSG A (4S)
0.009 98 TOTAL AREA
874 East Sixth Building entry Driveway
3793-874 east sixth-REV11-18-19 Printed 5/22/2020Prepared by Civil Environmental Consultants LLC
Page 4HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Soil Listing (selected nodes)
Area
(acres)
Soil
Group
Subcatchment
Numbers
0.009 HSG A 4S
0.000 HSG B
0.000 HSG C
0.000 HSG D
0.000 Other
0.009 TOTAL AREA
874 East Sixth Building entry Driveway
3793-874 east sixth-REV11-18-19 Printed 5/22/2020Prepared by Civil Environmental Consultants LLC
Page 5HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Ground Covers (selected nodes)
HSG-A
(acres)
HSG-B
(acres)
HSG-C
(acres)
HSG-D
(acres)
Other
(acres)
Total
(acres)
Ground
Cover
Subcatchment
Numbers
0.009 0.000 0.000 0.000 0.000 0.009 Paved parking 4S
0.009 0.000 0.000 0.000 0.000 0.009 TOTAL AREA
874 East Sixth Building entry DrivewayNRCC 24-hr D 2-Year Rainfall=3.26"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 6HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Time span=0.00-24.00 hrs, dt=0.05 hrs, 481 pointsRunoff by SCS TR-20 method, UH=SCS, Weighted-CN
Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method
Runoff Area=380 sf 100.00% Impervious Runoff Depth>3.02"Subcatchment 4S: 874 E 6th Entry Driveway Tc=6.0 min CN=98 Runoff=0.02 cfs 0.002 af
Peak Elev=13.80' Storage=6 cf Inflow=0.02 cfs 0.002 afPond 5P: 1 CULTEC 330XLHD Outflow=0.01 cfs 0.002 af
Total Runoff Area = 0.009 ac Runoff Volume = 0.002 af Average Runoff Depth = 3.02"0.00% Pervious = 0.000 ac 100.00% Impervious = 0.009 ac
874 East Sixth Building entry DrivewayNRCC 24-hr D 2-Year Rainfall=3.26"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 7HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Subcatchment 4S: 874 E 6th Entry Driveway
Runoff = 0.02 cfs @ 12.13 hrs, Volume= 0.002 af, Depth> 3.02"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsNRCC 24-hr D 2-Year Rainfall=3.26"
Area (sf) CN Description
380 98 Paved parking, HSG A
380 100.00% Impervious Area
Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry, flow
Subcatchment 4S: 874 E 6th Entry Driveway
Runoff
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.026
0.024
0.022
0.02
0.018
0.016
0.014
0.012
0.01
0.008
0.006
0.004
0.002
0
NRCC 24-hr D
2-Year Rainfall=3.26"
Runoff Area=380 sf
Runoff Volume=0.002 af
Runoff Depth>3.02"
Tc=6.0 min
CN=98
0.02 cfs
874 East Sixth Building entry DrivewayNRCC 24-hr D 2-Year Rainfall=3.26"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 8HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Subcatchment 4S: 874 E 6th Entry Driveway
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
0.00 0.00 0.00 0.000.25 0.01 0.00 0.000.50 0.02 0.00 0.000.75 0.04 0.00 0.001.00 0.05 0.00 0.001.25 0.06 0.00 0.001.50 0.07 0.00 0.001.75 0.09 0.01 0.002.00 0.10 0.01 0.002.25 0.11 0.02 0.002.50 0.12 0.02 0.002.75 0.14 0.03 0.003.00 0.15 0.04 0.003.25 0.17 0.05 0.003.50 0.18 0.06 0.003.75 0.20 0.07 0.004.00 0.21 0.08 0.004.25 0.23 0.09 0.004.50 0.24 0.10 0.004.75 0.26 0.11 0.005.00 0.27 0.12 0.005.25 0.29 0.13 0.005.50 0.30 0.15 0.005.75 0.32 0.16 0.006.00 0.34 0.17 0.006.25 0.35 0.19 0.006.50 0.37 0.20 0.006.75 0.39 0.22 0.007.00 0.41 0.24 0.007.25 0.43 0.26 0.007.50 0.45 0.27 0.007.75 0.47 0.29 0.008.00 0.50 0.32 0.008.25 0.52 0.34 0.008.50 0.55 0.36 0.008.75 0.57 0.38 0.009.00 0.60 0.41 0.009.25 0.63 0.44 0.009.50 0.66 0.46 0.009.75 0.69 0.50 0.00
10.00 0.73 0.53 0.0010.25 0.77 0.57 0.0010.50 0.81 0.61 0.0010.75 0.87 0.66 0.0011.00 0.93 0.72 0.0011.25 1.00 0.79 0.0011.50 1.09 0.88 0.0011.75 1.23 1.02 0.0012.00 1.56 1.34 0.0112.25 2.03 1.80 0.0112.50 2.17 1.94 0.00
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
12.75 2.26 2.03 0.0013.00 2.33 2.11 0.0013.25 2.39 2.17 0.0013.50 2.45 2.22 0.0013.75 2.49 2.26 0.0014.00 2.53 2.30 0.0014.25 2.57 2.34 0.0014.50 2.60 2.37 0.0014.75 2.63 2.40 0.0015.00 2.66 2.43 0.0015.25 2.69 2.46 0.0015.50 2.71 2.48 0.0015.75 2.74 2.51 0.0016.00 2.76 2.53 0.0016.25 2.79 2.56 0.0016.50 2.81 2.58 0.0016.75 2.83 2.60 0.0017.00 2.85 2.62 0.0017.25 2.87 2.64 0.0017.50 2.89 2.66 0.0017.75 2.91 2.68 0.0018.00 2.92 2.69 0.0018.25 2.94 2.71 0.0018.50 2.96 2.73 0.0018.75 2.97 2.74 0.0019.00 2.99 2.76 0.0019.25 3.00 2.77 0.0019.50 3.02 2.79 0.0019.75 3.03 2.80 0.0020.00 3.05 2.82 0.0020.25 3.06 2.83 0.0020.50 3.08 2.85 0.0020.75 3.09 2.86 0.0021.00 3.11 2.88 0.0021.25 3.12 2.89 0.0021.50 3.14 2.90 0.0021.75 3.15 2.92 0.0022.00 3.16 2.93 0.0022.25 3.17 2.94 0.0022.50 3.19 2.96 0.0022.75 3.20 2.97 0.0023.00 3.21 2.98 0.0023.25 3.22 2.99 0.0023.50 3.24 3.00 0.0023.75 3.25 3.02 0.0024.00 3.26 3.03 0.00
874 East Sixth Building entry DrivewayNRCC 24-hr D 2-Year Rainfall=3.26"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 9HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Pond 5P: 1 CULTEC 330XLHD
Inflow Area = 0.009 ac,100.00% Impervious, Inflow Depth > 3.02" for 2-Year eventInflow = 0.02 cfs @ 12.13 hrs, Volume= 0.002 afOutflow = 0.01 cfs @ 12.05 hrs, Volume= 0.002 af, Atten= 48%, Lag= 0.0 minDiscarded = 0.01 cfs @ 12.05 hrs, Volume= 0.002 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsPeak Elev= 13.80' @ 12.23 hrs Surf.Area= 67 sf Storage= 6 cf
Plug-Flow detention time= 1.8 min calculated for 0.002 af (100% of inflow)Center-of-Mass det. time= 1.7 min ( 760.9 - 759.2 )
Volume Invert Avail.Storage Storage Description
#1A 13.50' 52 cf 6.33'W x 10.50'L x 3.54'H Field A236 cf Overall - 63 cf Embedded = 172 cf x 30.0% Voids
#2A 14.00' 63 cf Cultec R-330XLHD Inside #1Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cfOverall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' OverlapRow Length Adjustment= +1.50' x 7.45 sf x 1 rows
115 cf Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Discarded 13.50' 8.270 in/hr Exfiltration over Surface area
Discarded OutFlow Max=0.01 cfs @ 12.05 hrs HW=13.56' (Free Discharge)1=Exfiltration (Exfiltration Controls 0.01 cfs)
874 East Sixth Building entry DrivewayNRCC 24-hr D 2-Year Rainfall=3.26"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 10HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 5P: 1 CULTEC 330XLHD - Chamber Wizard Field A
Chamber Model = Cultec R-330XLHD (Cultec Recharger® 330XLHD)
Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cf
Overall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' Overlap
Row Length Adjustment= +1.50' x 7.45 sf x 1 rows
1 Chambers/Row x 7.00' Long +1.50' Row Adjustment = 8.50' Row Length +12.0" End Stone x 2 = 10.50'
Base Length
1 Rows x 52.0" Wide + 12.0" Side Stone x 2 = 6.33' Base Width
6.0" Base + 30.5" Chamber Height + 6.0" Cover = 3.54' Field Height
1 Chambers x 52.2 cf +1.50' Row Adjustment x 7.45 sf x 1 Rows = 63.3 cf Chamber Storage
235.5 cf Field - 63.3 cf Chambers = 172.2 cf Stone x 30.0% Voids = 51.7 cf Stone Storage
Chamber Storage + Stone Storage = 115.0 cf = 0.003 af
Overall Storage Efficiency = 48.8%
Overall System Size = 10.50' x 6.33' x 3.54'
1 Chambers
8.7 cy Field
6.4 cy Stone
874 East Sixth Building entry DrivewayNRCC 24-hr D 2-Year Rainfall=3.26"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 11HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 5P: 1 CULTEC 330XLHD
InflowDiscarded
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.026
0.024
0.022
0.02
0.018
0.016
0.014
0.012
0.01
0.008
0.006
0.004
0.002
0
Inflow Area=0.009 ac
Peak Elev=13.80'
Storage=6 cf
0.02 cfs
0.01 cfs
874 East Sixth Building entry DrivewayNRCC 24-hr D 2-Year Rainfall=3.26"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 12HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Pond 5P: 1 CULTEC 330XLHD
Time(hours)
Inflow(cfs)
Storage(cubic-feet)
Elevation(feet)
Discarded(cfs)
0.00 0.00 0 13.50 0.000.50 0.00 0 13.50 0.001.00 0.00 0 13.50 0.001.50 0.00 0 13.50 0.002.00 0.00 0 13.50 0.002.50 0.00 0 13.50 0.003.00 0.00 0 13.50 0.003.50 0.00 0 13.50 0.004.00 0.00 0 13.50 0.004.50 0.00 0 13.50 0.005.00 0.00 0 13.50 0.005.50 0.00 0 13.50 0.006.00 0.00 0 13.50 0.006.50 0.00 0 13.50 0.007.00 0.00 0 13.50 0.007.50 0.00 0 13.50 0.008.00 0.00 0 13.50 0.008.50 0.00 0 13.50 0.009.00 0.00 0 13.50 0.009.50 0.00 0 13.50 0.00
10.00 0.00 0 13.50 0.0010.50 0.00 0 13.50 0.0011.00 0.00 0 13.51 0.0011.50 0.00 0 13.51 0.0012.00 0.01 1 13.53 0.0112.50 0.00 1 13.53 0.0113.00 0.00 0 13.51 0.0013.50 0.00 0 13.50 0.0014.00 0.00 0 13.50 0.0014.50 0.00 0 13.50 0.0015.00 0.00 0 13.50 0.0015.50 0.00 0 13.50 0.0016.00 0.00 0 13.50 0.0016.50 0.00 0 13.50 0.0017.00 0.00 0 13.50 0.0017.50 0.00 0 13.50 0.0018.00 0.00 0 13.50 0.0018.50 0.00 0 13.50 0.0019.00 0.00 0 13.50 0.0019.50 0.00 0 13.50 0.0020.00 0.00 0 13.50 0.0020.50 0.00 0 13.50 0.0021.00 0.00 0 13.50 0.0021.50 0.00 0 13.50 0.0022.00 0.00 0 13.50 0.0022.50 0.00 0 13.50 0.0023.00 0.00 0 13.50 0.0023.50 0.00 0 13.50 0.0024.00 0.00 0 13.50 0.00
874 East Sixth Building entry DrivewayNRCC 24-hr D 10-Year Rainfall=4.90"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 13HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Time span=0.00-24.00 hrs, dt=0.05 hrs, 481 pointsRunoff by SCS TR-20 method, UH=SCS, Weighted-CN
Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method
Runoff Area=380 sf 100.00% Impervious Runoff Depth>4.66"Subcatchment 4S: 874 E 6th Entry Driveway Tc=6.0 min CN=98 Runoff=0.04 cfs 0.003 af
Peak Elev=14.14' Storage=16 cf Inflow=0.04 cfs 0.003 afPond 5P: 1 CULTEC 330XLHD Outflow=0.01 cfs 0.003 af
Total Runoff Area = 0.009 ac Runoff Volume = 0.003 af Average Runoff Depth = 4.66"0.00% Pervious = 0.000 ac 100.00% Impervious = 0.009 ac
874 East Sixth Building entry DrivewayNRCC 24-hr D 10-Year Rainfall=4.90"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 14HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Subcatchment 4S: 874 E 6th Entry Driveway
Runoff = 0.04 cfs @ 12.13 hrs, Volume= 0.003 af, Depth> 4.66"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsNRCC 24-hr D 10-Year Rainfall=4.90"
Area (sf) CN Description
380 98 Paved parking, HSG A
380 100.00% Impervious Area
Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry, flow
Subcatchment 4S: 874 E 6th Entry Driveway
Runoff
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.04
0.038
0.036
0.034
0.032
0.03
0.028
0.026
0.024
0.022
0.02
0.018
0.016
0.014
0.012
0.01
0.008
0.006
0.004
0.002
0
NRCC 24-hr D
10-Year Rainfall=4.90"
Runoff Area=380 sf
Runoff Volume=0.003 af
Runoff Depth>4.66"
Tc=6.0 min
CN=98
0.04 cfs
874 East Sixth Building entry DrivewayNRCC 24-hr D 10-Year Rainfall=4.90"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 15HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Subcatchment 4S: 874 E 6th Entry Driveway
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
0.00 0.00 0.00 0.000.25 0.02 0.00 0.000.50 0.04 0.00 0.000.75 0.05 0.00 0.001.00 0.07 0.00 0.001.25 0.09 0.01 0.001.50 0.11 0.02 0.001.75 0.13 0.03 0.002.00 0.15 0.04 0.002.25 0.17 0.05 0.002.50 0.19 0.06 0.002.75 0.21 0.08 0.003.00 0.23 0.09 0.003.25 0.25 0.11 0.003.50 0.27 0.12 0.003.75 0.29 0.14 0.004.00 0.32 0.16 0.004.25 0.34 0.18 0.004.50 0.36 0.20 0.004.75 0.38 0.22 0.005.00 0.41 0.24 0.005.25 0.43 0.26 0.005.50 0.46 0.28 0.005.75 0.48 0.30 0.006.00 0.50 0.32 0.006.25 0.53 0.35 0.006.50 0.56 0.37 0.006.75 0.59 0.40 0.007.00 0.62 0.42 0.007.25 0.65 0.45 0.007.50 0.68 0.48 0.007.75 0.71 0.51 0.008.00 0.75 0.55 0.008.25 0.78 0.58 0.008.50 0.82 0.62 0.008.75 0.86 0.66 0.009.00 0.90 0.69 0.009.25 0.94 0.74 0.009.50 0.99 0.78 0.009.75 1.04 0.83 0.00
10.00 1.10 0.89 0.0010.25 1.16 0.95 0.0010.50 1.22 1.01 0.0010.75 1.30 1.08 0.0011.00 1.39 1.17 0.0011.25 1.51 1.29 0.0011.50 1.64 1.42 0.0011.75 1.85 1.63 0.0112.00 2.35 2.12 0.0212.25 3.05 2.82 0.0212.50 3.26 3.03 0.01
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
12.75 3.39 3.16 0.0013.00 3.51 3.27 0.0013.25 3.60 3.37 0.0013.50 3.68 3.44 0.0013.75 3.74 3.51 0.0014.00 3.80 3.57 0.0014.25 3.86 3.62 0.0014.50 3.91 3.67 0.0014.75 3.96 3.72 0.0015.00 4.00 3.77 0.0015.25 4.04 3.81 0.0015.50 4.08 3.84 0.0015.75 4.12 3.88 0.0016.00 4.15 3.92 0.0016.25 4.19 3.95 0.0016.50 4.22 3.99 0.0016.75 4.25 4.02 0.0017.00 4.28 4.05 0.0017.25 4.31 4.08 0.0017.50 4.34 4.11 0.0017.75 4.37 4.13 0.0018.00 4.40 4.16 0.0018.25 4.42 4.18 0.0018.50 4.44 4.21 0.0018.75 4.47 4.23 0.0019.00 4.49 4.26 0.0019.25 4.52 4.28 0.0019.50 4.54 4.30 0.0019.75 4.56 4.33 0.0020.00 4.58 4.35 0.0020.25 4.61 4.37 0.0020.50 4.63 4.39 0.0020.75 4.65 4.41 0.0021.00 4.67 4.43 0.0021.25 4.69 4.46 0.0021.50 4.71 4.48 0.0021.75 4.73 4.50 0.0022.00 4.75 4.52 0.0022.25 4.77 4.54 0.0022.50 4.79 4.55 0.0022.75 4.81 4.57 0.0023.00 4.83 4.59 0.0023.25 4.85 4.61 0.0023.50 4.86 4.63 0.0023.75 4.88 4.65 0.0024.00 4.90 4.66 0.00
874 East Sixth Building entry DrivewayNRCC 24-hr D 10-Year Rainfall=4.90"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 16HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Pond 5P: 1 CULTEC 330XLHD
Inflow Area = 0.009 ac,100.00% Impervious, Inflow Depth > 4.66" for 10-Year eventInflow = 0.04 cfs @ 12.13 hrs, Volume= 0.003 afOutflow = 0.01 cfs @ 11.95 hrs, Volume= 0.003 af, Atten= 66%, Lag= 0.0 minDiscarded = 0.01 cfs @ 11.95 hrs, Volume= 0.003 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsPeak Elev= 14.14' @ 12.30 hrs Surf.Area= 67 sf Storage= 16 cf
Plug-Flow detention time= (not calculated: outflow precedes inflow)Center-of-Mass det. time= 4.2 min ( 754.4 - 750.2 )
Volume Invert Avail.Storage Storage Description
#1A 13.50' 52 cf 6.33'W x 10.50'L x 3.54'H Field A236 cf Overall - 63 cf Embedded = 172 cf x 30.0% Voids
#2A 14.00' 63 cf Cultec R-330XLHD Inside #1Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cfOverall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' OverlapRow Length Adjustment= +1.50' x 7.45 sf x 1 rows
115 cf Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Discarded 13.50' 8.270 in/hr Exfiltration over Surface area
Discarded OutFlow Max=0.01 cfs @ 11.95 hrs HW=13.55' (Free Discharge)1=Exfiltration (Exfiltration Controls 0.01 cfs)
874 East Sixth Building entry DrivewayNRCC 24-hr D 10-Year Rainfall=4.90"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 17HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 5P: 1 CULTEC 330XLHD - Chamber Wizard Field A
Chamber Model = Cultec R-330XLHD (Cultec Recharger® 330XLHD)
Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cf
Overall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' Overlap
Row Length Adjustment= +1.50' x 7.45 sf x 1 rows
1 Chambers/Row x 7.00' Long +1.50' Row Adjustment = 8.50' Row Length +12.0" End Stone x 2 = 10.50'
Base Length
1 Rows x 52.0" Wide + 12.0" Side Stone x 2 = 6.33' Base Width
6.0" Base + 30.5" Chamber Height + 6.0" Cover = 3.54' Field Height
1 Chambers x 52.2 cf +1.50' Row Adjustment x 7.45 sf x 1 Rows = 63.3 cf Chamber Storage
235.5 cf Field - 63.3 cf Chambers = 172.2 cf Stone x 30.0% Voids = 51.7 cf Stone Storage
Chamber Storage + Stone Storage = 115.0 cf = 0.003 af
Overall Storage Efficiency = 48.8%
Overall System Size = 10.50' x 6.33' x 3.54'
1 Chambers
8.7 cy Field
6.4 cy Stone
874 East Sixth Building entry DrivewayNRCC 24-hr D 10-Year Rainfall=4.90"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 18HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 5P: 1 CULTEC 330XLHD
InflowDiscarded
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.04
0.038
0.036
0.034
0.032
0.03
0.028
0.026
0.024
0.022
0.02
0.018
0.016
0.014
0.012
0.01
0.008
0.006
0.004
0.002
0
Inflow Area=0.009 ac
Peak Elev=14.14'
Storage=16 cf
0.04 cfs
0.01 cfs
874 East Sixth Building entry DrivewayNRCC 24-hr D 10-Year Rainfall=4.90"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 19HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Pond 5P: 1 CULTEC 330XLHD
Time(hours)
Inflow(cfs)
Storage(cubic-feet)
Elevation(feet)
Discarded(cfs)
0.00 0.00 0 13.50 0.000.50 0.00 0 13.50 0.001.00 0.00 0 13.50 0.001.50 0.00 0 13.50 0.002.00 0.00 0 13.50 0.002.50 0.00 0 13.50 0.003.00 0.00 0 13.50 0.003.50 0.00 0 13.50 0.004.00 0.00 0 13.50 0.004.50 0.00 0 13.50 0.005.00 0.00 0 13.50 0.005.50 0.00 0 13.50 0.006.00 0.00 0 13.50 0.006.50 0.00 0 13.50 0.007.00 0.00 0 13.50 0.007.50 0.00 0 13.50 0.008.00 0.00 0 13.50 0.008.50 0.00 0 13.50 0.009.00 0.00 0 13.50 0.009.50 0.00 0 13.50 0.00
10.00 0.00 0 13.51 0.0010.50 0.00 0 13.51 0.0011.00 0.00 0 13.51 0.0011.50 0.00 0 13.51 0.0012.00 0.02 2 13.59 0.0112.50 0.01 13 14.07 0.0113.00 0.00 0 13.51 0.0013.50 0.00 0 13.51 0.0014.00 0.00 0 13.51 0.0014.50 0.00 0 13.51 0.0015.00 0.00 0 13.50 0.0015.50 0.00 0 13.50 0.0016.00 0.00 0 13.50 0.0016.50 0.00 0 13.50 0.0017.00 0.00 0 13.50 0.0017.50 0.00 0 13.50 0.0018.00 0.00 0 13.50 0.0018.50 0.00 0 13.50 0.0019.00 0.00 0 13.50 0.0019.50 0.00 0 13.50 0.0020.00 0.00 0 13.50 0.0020.50 0.00 0 13.50 0.0021.00 0.00 0 13.50 0.0021.50 0.00 0 13.50 0.0022.00 0.00 0 13.50 0.0022.50 0.00 0 13.50 0.0023.00 0.00 0 13.50 0.0023.50 0.00 0 13.50 0.0024.00 0.00 0 13.50 0.00
874 East Sixth Building entry DrivewayNRCC 24-hr D 25-Year Rainfall=6.19"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 20HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Time span=0.00-24.00 hrs, dt=0.05 hrs, 481 pointsRunoff by SCS TR-20 method, UH=SCS, Weighted-CN
Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method
Runoff Area=380 sf 100.00% Impervious Runoff Depth>5.95"Subcatchment 4S: 874 E 6th Entry Driveway Tc=6.0 min CN=98 Runoff=0.05 cfs 0.004 af
Peak Elev=14.35' Storage=25 cf Inflow=0.05 cfs 0.004 afPond 5P: 1 CULTEC 330XLHD Outflow=0.01 cfs 0.004 af
Total Runoff Area = 0.009 ac Runoff Volume = 0.004 af Average Runoff Depth = 5.95"0.00% Pervious = 0.000 ac 100.00% Impervious = 0.009 ac
874 East Sixth Building entry DrivewayNRCC 24-hr D 25-Year Rainfall=6.19"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 21HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Subcatchment 4S: 874 E 6th Entry Driveway
Runoff = 0.05 cfs @ 12.13 hrs, Volume= 0.004 af, Depth> 5.95"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsNRCC 24-hr D 25-Year Rainfall=6.19"
Area (sf) CN Description
380 98 Paved parking, HSG A
380 100.00% Impervious Area
Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry, flow
Subcatchment 4S: 874 E 6th Entry Driveway
Runoff
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.05
0.045
0.04
0.035
0.03
0.025
0.02
0.015
0.01
0.005
0
NRCC 24-hr D
25-Year Rainfall=6.19"
Runoff Area=380 sf
Runoff Volume=0.004 af
Runoff Depth>5.95"
Tc=6.0 min
CN=98
0.05 cfs
874 East Sixth Building entry DrivewayNRCC 24-hr D 25-Year Rainfall=6.19"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 22HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Subcatchment 4S: 874 E 6th Entry Driveway
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
0.00 0.00 0.00 0.000.25 0.02 0.00 0.000.50 0.04 0.00 0.000.75 0.07 0.00 0.001.00 0.09 0.01 0.001.25 0.11 0.02 0.001.50 0.14 0.03 0.001.75 0.16 0.05 0.002.00 0.19 0.06 0.002.25 0.21 0.08 0.002.50 0.24 0.10 0.002.75 0.26 0.12 0.003.00 0.29 0.14 0.003.25 0.32 0.16 0.003.50 0.34 0.18 0.003.75 0.37 0.20 0.004.00 0.40 0.23 0.004.25 0.43 0.25 0.004.50 0.46 0.28 0.004.75 0.49 0.30 0.005.00 0.51 0.33 0.005.25 0.54 0.36 0.005.50 0.58 0.39 0.005.75 0.61 0.42 0.006.00 0.64 0.44 0.006.25 0.67 0.48 0.006.50 0.70 0.51 0.006.75 0.74 0.54 0.007.00 0.78 0.58 0.007.25 0.82 0.61 0.007.50 0.86 0.65 0.007.75 0.90 0.69 0.008.00 0.94 0.74 0.008.25 0.99 0.78 0.008.50 1.04 0.83 0.008.75 1.09 0.87 0.009.00 1.14 0.92 0.009.25 1.19 0.98 0.009.50 1.25 1.04 0.009.75 1.32 1.10 0.00
10.00 1.39 1.17 0.0010.25 1.46 1.25 0.0010.50 1.55 1.33 0.0010.75 1.64 1.42 0.0011.00 1.76 1.54 0.0011.25 1.90 1.68 0.0111.50 2.07 1.85 0.0111.75 2.34 2.11 0.0112.00 2.97 2.73 0.0312.25 3.85 3.62 0.0212.50 4.12 3.88 0.01
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
12.75 4.29 4.05 0.0113.00 4.43 4.20 0.0013.25 4.55 4.31 0.0013.50 4.64 4.41 0.0013.75 4.73 4.49 0.0014.00 4.80 4.57 0.0014.25 4.87 4.64 0.0014.50 4.94 4.70 0.0014.75 5.00 4.76 0.0015.00 5.05 4.82 0.0015.25 5.10 4.87 0.0015.50 5.15 4.92 0.0015.75 5.20 4.96 0.0016.00 5.25 5.01 0.0016.25 5.29 5.05 0.0016.50 5.33 5.10 0.0016.75 5.37 5.14 0.0017.00 5.41 5.18 0.0017.25 5.45 5.21 0.0017.50 5.49 5.25 0.0017.75 5.52 5.28 0.0018.00 5.55 5.31 0.0018.25 5.58 5.35 0.0018.50 5.61 5.38 0.0018.75 5.65 5.41 0.0019.00 5.68 5.44 0.0019.25 5.70 5.47 0.0019.50 5.73 5.50 0.0019.75 5.76 5.52 0.0020.00 5.79 5.55 0.0020.25 5.82 5.58 0.0020.50 5.85 5.61 0.0020.75 5.87 5.64 0.0021.00 5.90 5.66 0.0021.25 5.93 5.69 0.0021.50 5.95 5.71 0.0021.75 5.98 5.74 0.0022.00 6.00 5.77 0.0022.25 6.03 5.79 0.0022.50 6.05 5.81 0.0022.75 6.08 5.84 0.0023.00 6.10 5.86 0.0023.25 6.12 5.88 0.0023.50 6.15 5.91 0.0023.75 6.17 5.93 0.0024.00 6.19 5.95 0.00
874 East Sixth Building entry DrivewayNRCC 24-hr D 25-Year Rainfall=6.19"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 23HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Pond 5P: 1 CULTEC 330XLHD
Inflow Area = 0.009 ac,100.00% Impervious, Inflow Depth > 5.95" for 25-Year eventInflow = 0.05 cfs @ 12.13 hrs, Volume= 0.004 afOutflow = 0.01 cfs @ 11.90 hrs, Volume= 0.004 af, Atten= 73%, Lag= 0.0 minDiscarded = 0.01 cfs @ 11.90 hrs, Volume= 0.004 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsPeak Elev= 14.35' @ 12.35 hrs Surf.Area= 67 sf Storage= 25 cf
Plug-Flow detention time= 7.4 min calculated for 0.004 af (100% of inflow)Center-of-Mass det. time= 7.3 min ( 753.2 - 745.9 )
Volume Invert Avail.Storage Storage Description
#1A 13.50' 52 cf 6.33'W x 10.50'L x 3.54'H Field A236 cf Overall - 63 cf Embedded = 172 cf x 30.0% Voids
#2A 14.00' 63 cf Cultec R-330XLHD Inside #1Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cfOverall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' OverlapRow Length Adjustment= +1.50' x 7.45 sf x 1 rows
115 cf Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Discarded 13.50' 8.270 in/hr Exfiltration over Surface area
Discarded OutFlow Max=0.01 cfs @ 11.90 hrs HW=13.55' (Free Discharge)1=Exfiltration (Exfiltration Controls 0.01 cfs)
874 East Sixth Building entry DrivewayNRCC 24-hr D 25-Year Rainfall=6.19"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 24HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 5P: 1 CULTEC 330XLHD - Chamber Wizard Field A
Chamber Model = Cultec R-330XLHD (Cultec Recharger® 330XLHD)
Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cf
Overall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' Overlap
Row Length Adjustment= +1.50' x 7.45 sf x 1 rows
1 Chambers/Row x 7.00' Long +1.50' Row Adjustment = 8.50' Row Length +12.0" End Stone x 2 = 10.50'
Base Length
1 Rows x 52.0" Wide + 12.0" Side Stone x 2 = 6.33' Base Width
6.0" Base + 30.5" Chamber Height + 6.0" Cover = 3.54' Field Height
1 Chambers x 52.2 cf +1.50' Row Adjustment x 7.45 sf x 1 Rows = 63.3 cf Chamber Storage
235.5 cf Field - 63.3 cf Chambers = 172.2 cf Stone x 30.0% Voids = 51.7 cf Stone Storage
Chamber Storage + Stone Storage = 115.0 cf = 0.003 af
Overall Storage Efficiency = 48.8%
Overall System Size = 10.50' x 6.33' x 3.54'
1 Chambers
8.7 cy Field
6.4 cy Stone
874 East Sixth Building entry DrivewayNRCC 24-hr D 25-Year Rainfall=6.19"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 25HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 5P: 1 CULTEC 330XLHD
InflowDiscarded
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.05
0.045
0.04
0.035
0.03
0.025
0.02
0.015
0.01
0.005
0
Inflow Area=0.009 ac
Peak Elev=14.35'
Storage=25 cf
0.05 cfs
0.01 cfs
874 East Sixth Building entry DrivewayNRCC 24-hr D 25-Year Rainfall=6.19"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 26HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Pond 5P: 1 CULTEC 330XLHD
Time(hours)
Inflow(cfs)
Storage(cubic-feet)
Elevation(feet)
Discarded(cfs)
0.00 0.00 0 13.50 0.000.50 0.00 0 13.50 0.001.00 0.00 0 13.50 0.001.50 0.00 0 13.50 0.002.00 0.00 0 13.50 0.002.50 0.00 0 13.50 0.003.00 0.00 0 13.50 0.003.50 0.00 0 13.50 0.004.00 0.00 0 13.50 0.004.50 0.00 0 13.50 0.005.00 0.00 0 13.50 0.005.50 0.00 0 13.50 0.006.00 0.00 0 13.50 0.006.50 0.00 0 13.50 0.007.00 0.00 0 13.50 0.007.50 0.00 0 13.50 0.008.00 0.00 0 13.50 0.008.50 0.00 0 13.50 0.009.00 0.00 0 13.50 0.009.50 0.00 0 13.51 0.00
10.00 0.00 0 13.51 0.0010.50 0.00 0 13.51 0.0011.00 0.00 0 13.51 0.0011.50 0.01 0 13.52 0.0112.00 0.03 4 13.68 0.0112.50 0.01 24 14.32 0.0113.00 0.00 12 14.05 0.0113.50 0.00 0 13.51 0.0014.00 0.00 0 13.51 0.0014.50 0.00 0 13.51 0.0015.00 0.00 0 13.51 0.0015.50 0.00 0 13.50 0.0016.00 0.00 0 13.50 0.0016.50 0.00 0 13.50 0.0017.00 0.00 0 13.50 0.0017.50 0.00 0 13.50 0.0018.00 0.00 0 13.50 0.0018.50 0.00 0 13.50 0.0019.00 0.00 0 13.50 0.0019.50 0.00 0 13.50 0.0020.00 0.00 0 13.50 0.0020.50 0.00 0 13.50 0.0021.00 0.00 0 13.50 0.0021.50 0.00 0 13.50 0.0022.00 0.00 0 13.50 0.0022.50 0.00 0 13.50 0.0023.00 0.00 0 13.50 0.0023.50 0.00 0 13.50 0.0024.00 0.00 0 13.50 0.00
874 East Sixth Building entry DrivewayNRCC 24-hr D 100-Year Rainfall=8.83"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 27HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Time span=0.00-24.00 hrs, dt=0.05 hrs, 481 pointsRunoff by SCS TR-20 method, UH=SCS, Weighted-CN
Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method
Runoff Area=380 sf 100.00% Impervious Runoff Depth>8.58"Subcatchment 4S: 874 E 6th Entry Driveway Tc=6.0 min CN=98 Runoff=0.07 cfs 0.006 af
Peak Elev=14.88' Storage=47 cf Inflow=0.07 cfs 0.006 afPond 5P: 1 CULTEC 330XLHD Outflow=0.01 cfs 0.006 af
Total Runoff Area = 0.009 ac Runoff Volume = 0.006 af Average Runoff Depth = 8.58"0.00% Pervious = 0.000 ac 100.00% Impervious = 0.009 ac
874 East Sixth Building entry DrivewayNRCC 24-hr D 100-Year Rainfall=8.83"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 28HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Subcatchment 4S: 874 E 6th Entry Driveway
Runoff = 0.07 cfs @ 12.13 hrs, Volume= 0.006 af, Depth> 8.58"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsNRCC 24-hr D 100-Year Rainfall=8.83"
Area (sf) CN Description
380 98 Paved parking, HSG A
380 100.00% Impervious Area
Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry, flow
Subcatchment 4S: 874 E 6th Entry Driveway
Runoff
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.075
0.07
0.065
0.06
0.055
0.05
0.045
0.04
0.035
0.03
0.025
0.02
0.015
0.01
0.005
0
NRCC 24-hr D
100-Year Rainfall=8.83"
Runoff Area=380 sf
Runoff Volume=0.006 af
Runoff Depth>8.58"
Tc=6.0 min
CN=98
0.07 cfs
874 East Sixth Building entry DrivewayNRCC 24-hr D 100-Year Rainfall=8.83"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 29HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Subcatchment 4S: 874 E 6th Entry Driveway
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
0.00 0.00 0.00 0.000.25 0.03 0.00 0.000.50 0.06 0.00 0.000.75 0.10 0.01 0.001.00 0.13 0.03 0.001.25 0.16 0.05 0.001.50 0.20 0.07 0.001.75 0.23 0.09 0.002.00 0.27 0.12 0.002.25 0.30 0.15 0.002.50 0.34 0.18 0.002.75 0.38 0.21 0.003.00 0.41 0.24 0.003.25 0.45 0.27 0.003.50 0.49 0.31 0.003.75 0.53 0.34 0.004.00 0.57 0.38 0.004.25 0.61 0.42 0.004.50 0.65 0.46 0.004.75 0.69 0.50 0.005.00 0.73 0.54 0.005.25 0.78 0.58 0.005.50 0.82 0.62 0.005.75 0.86 0.66 0.006.00 0.91 0.70 0.006.25 0.96 0.75 0.006.50 1.00 0.80 0.006.75 1.06 0.85 0.007.00 1.11 0.90 0.007.25 1.16 0.95 0.007.50 1.22 1.01 0.007.75 1.28 1.07 0.008.00 1.35 1.13 0.008.25 1.41 1.19 0.008.50 1.48 1.26 0.008.75 1.55 1.33 0.009.00 1.62 1.40 0.009.25 1.70 1.48 0.009.50 1.78 1.56 0.009.75 1.88 1.65 0.00
10.00 1.98 1.75 0.0010.25 2.09 1.86 0.0010.50 2.21 1.98 0.0010.75 2.34 2.12 0.0011.00 2.51 2.28 0.0111.25 2.71 2.48 0.0111.50 2.96 2.73 0.0111.75 3.34 3.10 0.0112.00 4.23 3.99 0.0412.25 5.49 5.26 0.0312.50 5.87 5.63 0.01
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
12.75 6.12 5.88 0.0113.00 6.32 6.08 0.0113.25 6.49 6.25 0.0113.50 6.62 6.39 0.0013.75 6.74 6.50 0.0014.00 6.85 6.61 0.0014.25 6.95 6.71 0.0014.50 7.05 6.81 0.0014.75 7.13 6.89 0.0015.00 7.21 6.97 0.0015.25 7.28 7.04 0.0015.50 7.35 7.11 0.0015.75 7.42 7.18 0.0016.00 7.48 7.24 0.0016.25 7.55 7.31 0.0016.50 7.61 7.37 0.0016.75 7.67 7.43 0.0017.00 7.72 7.48 0.0017.25 7.77 7.53 0.0017.50 7.83 7.59 0.0017.75 7.87 7.63 0.0018.00 7.92 7.68 0.0018.25 7.97 7.73 0.0018.50 8.01 7.77 0.0018.75 8.05 7.81 0.0019.00 8.10 7.86 0.0019.25 8.14 7.90 0.0019.50 8.18 7.94 0.0019.75 8.22 7.98 0.0020.00 8.26 8.02 0.0020.25 8.30 8.06 0.0020.50 8.34 8.10 0.0020.75 8.38 8.14 0.0021.00 8.42 8.18 0.0021.25 8.45 8.21 0.0021.50 8.49 8.25 0.0021.75 8.53 8.29 0.0022.00 8.56 8.32 0.0022.25 8.60 8.36 0.0022.50 8.63 8.39 0.0022.75 8.67 8.43 0.0023.00 8.70 8.46 0.0023.25 8.73 8.49 0.0023.50 8.77 8.53 0.0023.75 8.80 8.56 0.0024.00 8.83 8.59 0.00
874 East Sixth Building entry DrivewayNRCC 24-hr D 100-Year Rainfall=8.83"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 30HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Pond 5P: 1 CULTEC 330XLHD
Inflow Area = 0.009 ac,100.00% Impervious, Inflow Depth > 8.58" for 100-Year eventInflow = 0.07 cfs @ 12.13 hrs, Volume= 0.006 afOutflow = 0.01 cfs @ 11.75 hrs, Volume= 0.006 af, Atten= 81%, Lag= 0.0 minDiscarded = 0.01 cfs @ 11.75 hrs, Volume= 0.006 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsPeak Elev= 14.88' @ 12.47 hrs Surf.Area= 67 sf Storage= 47 cf
Plug-Flow detention time= 16.3 min calculated for 0.006 af (100% of inflow)Center-of-Mass det. time= 16.1 min ( 756.7 - 740.6 )
Volume Invert Avail.Storage Storage Description
#1A 13.50' 52 cf 6.33'W x 10.50'L x 3.54'H Field A236 cf Overall - 63 cf Embedded = 172 cf x 30.0% Voids
#2A 14.00' 63 cf Cultec R-330XLHD Inside #1Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cfOverall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' OverlapRow Length Adjustment= +1.50' x 7.45 sf x 1 rows
115 cf Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Discarded 13.50' 8.270 in/hr Exfiltration over Surface area
Discarded OutFlow Max=0.01 cfs @ 11.75 hrs HW=13.54' (Free Discharge)1=Exfiltration (Exfiltration Controls 0.01 cfs)
874 East Sixth Building entry DrivewayNRCC 24-hr D 100-Year Rainfall=8.83"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 31HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 5P: 1 CULTEC 330XLHD - Chamber Wizard Field A
Chamber Model = Cultec R-330XLHD (Cultec Recharger® 330XLHD)
Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cf
Overall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' Overlap
Row Length Adjustment= +1.50' x 7.45 sf x 1 rows
1 Chambers/Row x 7.00' Long +1.50' Row Adjustment = 8.50' Row Length +12.0" End Stone x 2 = 10.50'
Base Length
1 Rows x 52.0" Wide + 12.0" Side Stone x 2 = 6.33' Base Width
6.0" Base + 30.5" Chamber Height + 6.0" Cover = 3.54' Field Height
1 Chambers x 52.2 cf +1.50' Row Adjustment x 7.45 sf x 1 Rows = 63.3 cf Chamber Storage
235.5 cf Field - 63.3 cf Chambers = 172.2 cf Stone x 30.0% Voids = 51.7 cf Stone Storage
Chamber Storage + Stone Storage = 115.0 cf = 0.003 af
Overall Storage Efficiency = 48.8%
Overall System Size = 10.50' x 6.33' x 3.54'
1 Chambers
8.7 cy Field
6.4 cy Stone
874 East Sixth Building entry DrivewayNRCC 24-hr D 100-Year Rainfall=8.83"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 32HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 5P: 1 CULTEC 330XLHD
InflowDiscarded
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.075
0.07
0.065
0.06
0.055
0.05
0.045
0.04
0.035
0.03
0.025
0.02
0.015
0.01
0.005
0
Inflow Area=0.009 ac
Peak Elev=14.88'
Storage=47 cf
0.07 cfs
0.01 cfs
874 East Sixth Building entry DrivewayNRCC 24-hr D 100-Year Rainfall=8.83"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 33HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Pond 5P: 1 CULTEC 330XLHD
Time(hours)
Inflow(cfs)
Storage(cubic-feet)
Elevation(feet)
Discarded(cfs)
0.00 0.00 0 13.50 0.000.50 0.00 0 13.50 0.001.00 0.00 0 13.50 0.001.50 0.00 0 13.50 0.002.00 0.00 0 13.50 0.002.50 0.00 0 13.50 0.003.00 0.00 0 13.50 0.003.50 0.00 0 13.50 0.004.00 0.00 0 13.50 0.004.50 0.00 0 13.50 0.005.00 0.00 0 13.50 0.005.50 0.00 0 13.50 0.006.00 0.00 0 13.50 0.006.50 0.00 0 13.50 0.007.00 0.00 0 13.51 0.007.50 0.00 0 13.51 0.008.00 0.00 0 13.51 0.008.50 0.00 0 13.51 0.009.00 0.00 0 13.51 0.009.50 0.00 0 13.51 0.00
10.00 0.00 0 13.51 0.0010.50 0.00 0 13.51 0.0011.00 0.01 0 13.52 0.0111.50 0.01 0 13.52 0.0112.00 0.04 9 13.94 0.0112.50 0.01 47 14.88 0.0113.00 0.01 41 14.71 0.0113.50 0.00 28 14.41 0.0114.00 0.00 12 14.06 0.0114.50 0.00 0 13.51 0.0015.00 0.00 0 13.51 0.0015.50 0.00 0 13.51 0.0016.00 0.00 0 13.51 0.0016.50 0.00 0 13.51 0.0017.00 0.00 0 13.51 0.0017.50 0.00 0 13.50 0.0018.00 0.00 0 13.50 0.0018.50 0.00 0 13.50 0.0019.00 0.00 0 13.50 0.0019.50 0.00 0 13.50 0.0020.00 0.00 0 13.50 0.0020.50 0.00 0 13.50 0.0021.00 0.00 0 13.50 0.0021.50 0.00 0 13.50 0.0022.00 0.00 0 13.50 0.0022.50 0.00 0 13.50 0.0023.00 0.00 0 13.50 0.0023.50 0.00 0 13.50 0.0024.00 0.00 0 13.50 0.00
874 East Sixth Building entry DrivewayNRCC 24-hr D Custom Rainfall=1.00"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 34HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Time span=0.00-24.00 hrs, dt=0.05 hrs, 481 pointsRunoff by SCS TR-20 method, UH=SCS, Weighted-CN
Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method
Runoff Area=380 sf 100.00% Impervious Runoff Depth>0.79"Subcatchment 4S: 874 E 6th Entry Driveway Tc=6.0 min CN=98 Runoff=0.01 cfs 0.001 af
Peak Elev=13.52' Storage=0 cf Inflow=0.01 cfs 0.001 afPond 5P: 1 CULTEC 330XLHD Outflow=0.01 cfs 0.001 af
Total Runoff Area = 0.009 ac Runoff Volume = 0.001 af Average Runoff Depth = 0.79"0.00% Pervious = 0.000 ac 100.00% Impervious = 0.009 ac
874 East Sixth Building entry DrivewayNRCC 24-hr D Custom Rainfall=1.00"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 35HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Subcatchment 4S: 874 E 6th Entry Driveway
Runoff = 0.01 cfs @ 12.13 hrs, Volume= 0.001 af, Depth> 0.79"
Runoff by SCS TR-20 method, UH=SCS, Weighted-CN, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsNRCC 24-hr D Custom Rainfall=1.00"
Area (sf) CN Description
380 98 Paved parking, HSG A
380 100.00% Impervious Area
Tc Length Slope Velocity Capacity Description(min) (feet) (ft/ft) (ft/sec) (cfs)
6.0 Direct Entry, flow
Subcatchment 4S: 874 E 6th Entry Driveway
Runoff
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.007
0.007
0.006
0.006
0.005
0.005
0.004
0.004
0.003
0.003
0.002
0.002
0.001
0.001
0.000
0
NRCC 24-hr D
Custom Rainfall=1.00"
Runoff Area=380 sf
Runoff Volume=0.001 af
Runoff Depth>0.79"
Tc=6.0 min
CN=98
0.01 cfs
874 East Sixth Building entry DrivewayNRCC 24-hr D Custom Rainfall=1.00"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 36HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Subcatchment 4S: 874 E 6th Entry Driveway
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
0.00 0.00 0.00 0.000.25 0.00 0.00 0.000.50 0.01 0.00 0.000.75 0.01 0.00 0.001.00 0.01 0.00 0.001.25 0.02 0.00 0.001.50 0.02 0.00 0.001.75 0.03 0.00 0.002.00 0.03 0.00 0.002.25 0.03 0.00 0.002.50 0.04 0.00 0.002.75 0.04 0.00 0.003.00 0.05 0.00 0.003.25 0.05 0.00 0.003.50 0.06 0.00 0.003.75 0.06 0.00 0.004.00 0.06 0.00 0.004.25 0.07 0.00 0.004.50 0.07 0.00 0.004.75 0.08 0.01 0.005.00 0.08 0.01 0.005.25 0.09 0.01 0.005.50 0.09 0.01 0.005.75 0.10 0.01 0.006.00 0.10 0.01 0.006.25 0.11 0.02 0.006.50 0.11 0.02 0.006.75 0.12 0.02 0.007.00 0.13 0.02 0.007.25 0.13 0.03 0.007.50 0.14 0.03 0.007.75 0.15 0.04 0.008.00 0.15 0.04 0.008.25 0.16 0.04 0.008.50 0.17 0.05 0.008.75 0.18 0.05 0.009.00 0.18 0.06 0.009.25 0.19 0.06 0.009.50 0.20 0.07 0.009.75 0.21 0.08 0.00
10.00 0.22 0.09 0.0010.25 0.24 0.10 0.0010.50 0.25 0.11 0.0010.75 0.27 0.12 0.0011.00 0.28 0.13 0.0011.25 0.31 0.15 0.0011.50 0.33 0.17 0.0011.75 0.38 0.21 0.0012.00 0.48 0.30 0.0012.25 0.62 0.43 0.0012.50 0.66 0.47 0.00
Time(hours)
Precip.(inches)
Excess(inches)
Runoff(cfs)
12.75 0.69 0.50 0.0013.00 0.72 0.52 0.0013.25 0.73 0.54 0.0013.50 0.75 0.55 0.0013.75 0.76 0.56 0.0014.00 0.78 0.58 0.0014.25 0.79 0.59 0.0014.50 0.80 0.60 0.0014.75 0.81 0.61 0.0015.00 0.82 0.61 0.0015.25 0.82 0.62 0.0015.50 0.83 0.63 0.0015.75 0.84 0.64 0.0016.00 0.85 0.64 0.0016.25 0.85 0.65 0.0016.50 0.86 0.66 0.0016.75 0.87 0.66 0.0017.00 0.87 0.67 0.0017.25 0.88 0.68 0.0017.50 0.89 0.68 0.0017.75 0.89 0.69 0.0018.00 0.90 0.69 0.0018.25 0.90 0.70 0.0018.50 0.91 0.70 0.0018.75 0.91 0.71 0.0019.00 0.92 0.71 0.0019.25 0.92 0.72 0.0019.50 0.93 0.72 0.0019.75 0.93 0.72 0.0020.00 0.94 0.73 0.0020.25 0.94 0.73 0.0020.50 0.94 0.74 0.0020.75 0.95 0.74 0.0021.00 0.95 0.75 0.0021.25 0.96 0.75 0.0021.50 0.96 0.75 0.0021.75 0.97 0.76 0.0022.00 0.97 0.76 0.0022.25 0.97 0.77 0.0022.50 0.98 0.77 0.0022.75 0.98 0.77 0.0023.00 0.99 0.78 0.0023.25 0.99 0.78 0.0023.50 0.99 0.78 0.0023.75 1.00 0.79 0.0024.00 1.00 0.79 0.00
874 East Sixth Building entry DrivewayNRCC 24-hr D Custom Rainfall=1.00"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 37HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Summary for Pond 5P: 1 CULTEC 330XLHD
Inflow Area = 0.009 ac,100.00% Impervious, Inflow Depth > 0.79" for Custom eventInflow = 0.01 cfs @ 12.13 hrs, Volume= 0.001 afOutflow = 0.01 cfs @ 12.14 hrs, Volume= 0.001 af, Atten= 2%, Lag= 0.9 minDiscarded = 0.01 cfs @ 12.14 hrs, Volume= 0.001 af
Routing by Stor-Ind method, Time Span= 0.00-24.00 hrs, dt= 0.05 hrsPeak Elev= 13.52' @ 12.14 hrs Surf.Area= 67 sf Storage= 0 cf
Plug-Flow detention time= 0.9 min calculated for 0.001 af (100% of inflow)Center-of-Mass det. time= 0.7 min ( 799.6 - 798.9 )
Volume Invert Avail.Storage Storage Description
#1A 13.50' 52 cf 6.33'W x 10.50'L x 3.54'H Field A236 cf Overall - 63 cf Embedded = 172 cf x 30.0% Voids
#2A 14.00' 63 cf Cultec R-330XLHD Inside #1Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cfOverall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' OverlapRow Length Adjustment= +1.50' x 7.45 sf x 1 rows
115 cf Total Available Storage
Storage Group A created with Chamber Wizard
Device Routing Invert Outlet Devices
#1 Discarded 13.50' 8.270 in/hr Exfiltration over Surface area
Discarded OutFlow Max=0.01 cfs @ 12.14 hrs HW=13.52' (Free Discharge)1=Exfiltration (Exfiltration Controls 0.01 cfs)
874 East Sixth Building entry DrivewayNRCC 24-hr D Custom Rainfall=1.00"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 38HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 5P: 1 CULTEC 330XLHD - Chamber Wizard Field A
Chamber Model = Cultec R-330XLHD (Cultec Recharger® 330XLHD)
Effective Size= 47.8"W x 30.0"H => 7.45 sf x 7.00'L = 52.2 cf
Overall Size= 52.0"W x 30.5"H x 8.50'L with 1.50' Overlap
Row Length Adjustment= +1.50' x 7.45 sf x 1 rows
1 Chambers/Row x 7.00' Long +1.50' Row Adjustment = 8.50' Row Length +12.0" End Stone x 2 = 10.50'
Base Length
1 Rows x 52.0" Wide + 12.0" Side Stone x 2 = 6.33' Base Width
6.0" Base + 30.5" Chamber Height + 6.0" Cover = 3.54' Field Height
1 Chambers x 52.2 cf +1.50' Row Adjustment x 7.45 sf x 1 Rows = 63.3 cf Chamber Storage
235.5 cf Field - 63.3 cf Chambers = 172.2 cf Stone x 30.0% Voids = 51.7 cf Stone Storage
Chamber Storage + Stone Storage = 115.0 cf = 0.003 af
Overall Storage Efficiency = 48.8%
Overall System Size = 10.50' x 6.33' x 3.54'
1 Chambers
8.7 cy Field
6.4 cy Stone
874 East Sixth Building entry DrivewayNRCC 24-hr D Custom Rainfall=1.00"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 39HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Pond 5P: 1 CULTEC 330XLHD
InflowDiscarded
Hydrograph
Time (hours)2423222120191817161514131211109876543210
Flo
w
(cfs
)
0.007
0.007
0.006
0.006
0.005
0.005
0.004
0.004
0.003
0.003
0.002
0.002
0.001
0.001
0.000
0
Inflow Area=0.009 ac
Peak Elev=13.52'
Storage=0 cf
0.01 cfs
0.01 cfs
874 East Sixth Building entry DrivewayNRCC 24-hr D Custom Rainfall=1.00"3793-874 east sixth-REV11-18-19
Printed 5/22/2020Prepared by Civil Environmental Consultants LLCPage 40HydroCAD® 10.00-25 s/n 09048 © 2019 HydroCAD Software Solutions LLC
Hydrograph for Pond 5P: 1 CULTEC 330XLHD
Time(hours)
Inflow(cfs)
Storage(cubic-feet)
Elevation(feet)
Discarded(cfs)
0.00 0.00 0 13.50 0.000.50 0.00 0 13.50 0.001.00 0.00 0 13.50 0.001.50 0.00 0 13.50 0.002.00 0.00 0 13.50 0.002.50 0.00 0 13.50 0.003.00 0.00 0 13.50 0.003.50 0.00 0 13.50 0.004.00 0.00 0 13.50 0.004.50 0.00 0 13.50 0.005.00 0.00 0 13.50 0.005.50 0.00 0 13.50 0.006.00 0.00 0 13.50 0.006.50 0.00 0 13.50 0.007.00 0.00 0 13.50 0.007.50 0.00 0 13.50 0.008.00 0.00 0 13.50 0.008.50 0.00 0 13.50 0.009.00 0.00 0 13.50 0.009.50 0.00 0 13.50 0.00
10.00 0.00 0 13.50 0.0010.50 0.00 0 13.50 0.0011.00 0.00 0 13.50 0.0011.50 0.00 0 13.50 0.0012.00 0.00 0 13.51 0.0012.50 0.00 0 13.50 0.0013.00 0.00 0 13.50 0.0013.50 0.00 0 13.50 0.0014.00 0.00 0 13.50 0.0014.50 0.00 0 13.50 0.0015.00 0.00 0 13.50 0.0015.50 0.00 0 13.50 0.0016.00 0.00 0 13.50 0.0016.50 0.00 0 13.50 0.0017.00 0.00 0 13.50 0.0017.50 0.00 0 13.50 0.0018.00 0.00 0 13.50 0.0018.50 0.00 0 13.50 0.0019.00 0.00 0 13.50 0.0019.50 0.00 0 13.50 0.0020.00 0.00 0 13.50 0.0020.50 0.00 0 13.50 0.0021.00 0.00 0 13.50 0.0021.50 0.00 0 13.50 0.0022.00 0.00 0 13.50 0.0022.50 0.00 0 13.50 0.0023.00 0.00 0 13.50 0.0023.50 0.00 0 13.50 0.0024.00 0.00 0 13.50 0.00
LIST of DRAWINGSCOVER SHEET
A4.2
A0.2
EXISTING CONDITIONS
A1.1 GROUND FLOOR & 1st FLOOR PLANA1.2
ARCHITECTURAL
SURVEY/CIVIL
FRONT ELEVATION
A4.3LEFT SIDE ELEVATION
A4.1
BUILDING SECTION A
PLOT PLANC1.0C1.1
STRUCTURAL
FIRE PROTECTION
REAR ELEVATIONA4.4
2nd & 3rd FLOOR PLANS, ROOF PLAN
STAIRWAY #1A5.1
WALL SECTIONSA6.1
A0.4FLOOR & CEILING ASSEMBLIESDOORS & WINDOWS
A0.1 ABBREVIATIONS, SYMBOLS, NOTES
A0.3
DETAILSA7.1
EXTERIOR WALLS & PARTITIONS
S0.1S0.2S0.3S0.4
S1.1S1.2
GENERAL NOTESTYPICAL CONCRETE DETAILS
FOUNDATION / GROUND FLOOR PLANFIRST FLOOR & SECOND FRAMING PLANTHIRD FLOOR & ROOF FRAMING
BPDA DESIGN REVIEW APPROVAL DWGS
BWSC SITE PLAN NO. 0000015461
S1.3
FIRE ALARM NOTE:FIRE ALARM PLANS BY OWNER
HVACH-1 HVAC PKG GARAGE, 1st & 2nd FLOOR PLANSH-2
P-1P-2P-3
F-11st & 2nd LEVEL FIRE PROTECTION PLANS
A3.1
RETAINING WALLES1-2
RIGHT SIDE ELEVATION
WOOD FRAMING DETAILS WOOD FRAMING DETAILS
DETAILSA7.2
H-3 HVAC NOTES, DETAILS & SCHEDULESHVAC 3rd FLOOR & ROOF PLANS
H-4 HVAC SCHEDULES & DETAILSH-5 HVAC DETAILS
PLUMBING
ELECTRICAL
P-4
PLUMBING PKG GARAGE, 1st & 2nd FLOOR PLANS
PLUMBING NOTES & SCHEDULESPLUMBING 3rd FLOOR & ROOF PLANS
PLUMBING NOTESPLUMBING DETAILSP-5
P-6 PLUMBING RISERS
E1.1 BASEMENT, 1st & 2nd FLOOR POWER PLANS3rd FLOOR & ROOF POWER PLANSE1.2BASEMENT, 1st & 2nd FLOOR LIGHTING PLANS3rd FLOOR & ROOF LIGHTING PLANS
E1.3E1.4
ELECTRICAL NOTES AND DETAILSE2.1ELECTRICAL NOTES, DIAGRAMS & SCHEDULESE2.2
BASEMENT LEVEL FIRE PROTECTION PLANF-2
3rd & ROOF LEVEL FIRE PROTECTION PLANSF-3
S0.5 CONCRETE FOUNDATION DETAILS
A0.0 EGRESS PLANS
BUILDING SECTIONS B & CA3.2BUILDING SECTION DA3.3
A1.3 ENLARGED PLANS
BUILDING SECTION EA3.4
STAIRWAY #1A5.2
WALL SECTIONSA6.2
ZBA REVIEW REQUIRED:
BUILDING AREA SUMMARY - ZONING
GR FLOOR
LOT AREA
SUBTOTAL
2nd FLOOR
1st FLOOR
FLOOR
PROPOSED USE:EXISTING USE:
MIN. REAR YARD
MIN. SIDE YARD
MIN. LOT WIDTH
BOSTON ZONING
ZONING, USE, LOT AREA
ZONING SUB-DISTRICT:
REAR YARD MAX OCCUPANCYby ACCESSORY BLDG
DIMENSIONAL REGULATIONS
OFF-STREET PARKING
MIN. LOT SIZE
MIN. USABLE OPEN SPACE /DWELLING UNIT
MIN. LOT AREA /EA ADD'L DWELLING UNIT
MAXIMUM ALLOWABLE'BUILDING HEIGHT
MIN. LOT FRONTAGE
MAXIMUM ALLOWABLE FAR
MIN. FRONT YARD
ADDRESS:
LOT AREA:
ARTICLE 68, Table D
ITEM
874 EAST 6th STREET, SOUTH BOSTON, MA
NONE
40'
20'
SOUTH BOSTON MAP 4F
6,250±SF
MFR
25%
200 SF/UNIT
2.0
NA
REQUIREMENT
20'
COMMENT
(1) USE "FAR (GROSS) AREA" TO DETERMINE PROPOSED FAR. AREA EXCLUSIONS TAKEN AS ALLOWED PER ZONING CODE.
ARTICLE 68 TABLE G
USE/REQUIREMENT REQUIRED PROPOSED COMMENT
MULTI-FAMILY DWELLING: USE NO. 7 - ALLOWED USE
PROPOSED
6,250 SF EXISTING
FAR (GROSS)AREA (1)
AREA
PROPOSEDBUILDING AREA ± SF / GSF
COMMENT
6,250 SFPROPOSED FAR
3rd FLOOR
0 GSF3,400
10,745 GSF
CONFORMS
N/A
ENTRY VESTIBULE, PARKING AND MECHANICALSPACES ONLY
ZONING DISTRICT:
OVERLAYS: GREENBELT PROTECTION; RESTRICTED PARKINGSINGLE-FAMILY DWELLING (TO BE DEMOLISHED)
20'
50' EXISTING
CONFORMS
CONFORMS
5'
ARTICLE 68, TABLE G:1.5 SPACES REQUIREDPER DWELLING UNIT.
6 UNITS x 1.5= 9.0
50' EXISTING
CONFORMS
1.7 CONFORMS
CONFORMS
CONFORMS
38'-6'
1,350 SF = 225 SF/UNIT
10' CONFORMS
3' 3' to 10'
20'
CONFORMS
CONFORMS
CONFORMS
9.0 CONFORMS
GPOD SITE PLAN COMPLIANCE
3,575 GSF3,625
3,715 3,580 GSF
3,590 GSF
NTE 1.72
PROJECT APPROVED BY ZBAZBA HEARING DATE MARCH 26, 2018DECISION SIGNED JUNE 20, 2018
595 SF LESS THAN ZBA APPROVED.
3,715
PROPOSED BUILDING AREA / OCCUPANT LOAD
FLOOR
GR FLOOR
1st
GROSS FLOORAREA (±SF)PER 1002.1
3,135
FLOOR AREAALLOWANCESTABLE 1004.1.1
RESIDENTIAL
COMMENT
2nd
3rd
USE OCC. COUNT
GARAGEPARKING 200 GSF/OCC 16
RESIDENTIALRESIDENTIAL
200 GSF/OCC3,575 18
200 GSF/OCC200 GSF/OCC
72
3,660
3,660
19
19
BUILDING CODE COMPLIANCE SUMMARYBUILDING CODE: 780 CMR 9TH EDITION:
2015 INTERNATIONAL BUILDING CODE (IBC 2015), AS AMENDED.2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC 2015), AS AMENDED.
PROPOSED HEIGHT: STORIES: 4 STORIES ABOVE GRADE PLANE, PARKING IN BASEMENT HEIGHT ABOVE GRADE PLANE: 40'
BUILDING TO BE EQUIPPED THROUGHOUT WITH AN APPROVED AUTOMATIC SPRINKLERSYSTEM IN ACCORDANCE WITH NFPA 13
PROPOSED USE: 310.4 RESIDENTIAL GROUP R-2 (APARTMENT HOUSE)
DIAGRAMMATIC BLDG SECTION (NTS)
R-2R-2R-2
GRADE PLANE
USE CLASSIFICATION STORY DESIGNATION/STORY ABOVE GRADE PLANE
S-2 PKG
BUILDING HEIGHT:
OCCUPANCY CLASSIFICATION R, SPRINKLERED PER 903.3.1.2: 60' OR LESS= MIN CONSTRUCTION TYPE VB.
CODE REF. DESCRIPTION
TABLE 504.3
CHAPTER 5 - BUILDING HEIGHTS AND AREAS / MINIMUM ALLOWABLE CONSTRUCTION TYPE
TABLE 504.4 STORIES ABOVE GRADE PLANE:
OCCUPANCY CLASSIFICATION R-2, SPRINKLERED PER 903.3.1.2: PROPOSED 4 STORIES ABOVE GRADE PLANE = MIN CONSTRUCTION TYPE VA
TABLE 506.2 ALLOWABLE AREA per FLOOR :
OCCUPANCY CLASSIFICATION R-2: MAX AREA FOR CONSTRUCTION TYPE VB, S13R: 7,000 SF ALLOWED.
PROPOSED AREA PER FLOOR IS FAR BELOW ALLOWABLE MAXIMUM FORTYPE VB CONSTRUCTION
PROPOSED CONSTRUCTION TYPE:
TYPE VA CONSTRUCTION MINIMUM.
TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES:
RESIDENTIAL R OCCUPANCIES SHALL BE SEPARATED FROM S-2 PARKING GARAGEOCCUPANCIES BY ASSEMBLIES WITH A MINIMUM FIRE-RESISTANCE RATING OF 1-HR.(1ST FLOOR SHALL BE RATED 2-HR IF IT SUPPORTS 2-HR RATED CONSTRUCTION.)
CHAPTER 6 - TYPES OF CONSTRUCTION
CODE REF. DESCRIPTION
TABLE 601
FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRESEPARATION DISTANCE (a)(d): USE GROUPS R AND S-2 CONSTRUCTION TYPE VA: X < 5': 1-HR 5' <= X < 10': 1-HR 10' <= X < 30': 1-HR X >= 30': 0-HRNOTES: (a) LOAD BEARING EXTERIOR WALLS SHALL ALSO COMPLY WITH TABLE 601. (d) FIRE RESISTANCE RATING OF WALL DETERMINED BY FIRE SEPARATION DISTANCE OF THE EXTERIOR WALL AND THE STORY IN WHICH THE WALL IS LOCATED.
TABLE 602
PRIMARY STRUCTURAL FRAME (f):
NOTES: (d) NOT LESS THAN FIRE RESISTANCE RATING REQUIRED BY OTHER SECTIONS OF THIS CODE. (e) NOT LESS THAN FIRE RESISTANCE RATING BASED ON FIRE SEPARATION DISTANCE (TABLE 602) (f) NOT LESS THAN FIRE RESISTANCE RATING PER 704.10.
FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS):
BEARING WALLS - EXTERIOR (e)(f):
BEARING WALLS - INTERIOR:
TYPE VA
1-HR
1-HR
1-HR*NON-BEARING WALLSAND PARTITIONS - EXTERIOR: 1-HR PER TABLE 602NON-BEARING WALLSAND PARTITIONS - INTERIOR (d):
0-HR/1-HR*
FLOOR CONSTRUCTIONAND SECONDARY MEMBERS:
* 1-HR SEPARATING DWELLING UNITS
1-HR
ROOF CONSTRUCTIONAND SECONDARY MEMBERS:
1-HR
MINIMUM REQUIREMENTS
*NO LESS THAN ELEMENT SUPPORTED
1. ALL OCCUPANT LOADS ROUNDED UP2. AREAS INCLUDE BALCONIES3. AREAS INCLUDE OUTDOOR AREAS BELOW PROJECTIONS OF FLOORS ABOVE
3/42/31/2G/11/2
FIRE SEPARATION DISTANCE (FEET)
CODE REF. DESCRIPTION
TABLE 705.8
CHAPTER 7 - FIRE AND SMOKE PROTECTION
NOTES: (a) PERCENTAGE OF EXTERIOR WALL PER STORY
0' - <3'
DEGREE OF OPG
PROTECTION
UP, NS
UP, S
P
NOTPERMITTED
3' - <5'
15%
5' - <10'
10%
25%
25%
10' - <15'
15%
45%
45%
15' - <20'
25%
75%
75%
NOTPERMITTED
NOTPERMITTED
NOTPERMITTED
20' - <25'
45%
NOLIMITNO
LIMIT
25' - <30'
70%
NOLIMITNO
LIMIT
30'+NO
LIMIT
UP, NS = UNPROTECTED, NON-SPRINKLEREDUP, S = UNPROTECTED, SPRINKLEREDP = PROTECTED
MAXIMUMALLOWABLEAREA OFEXTERIOR WALLOPENINGS (a)
705.11 PARAPET NOT REQUIRED PER EXCEPTION 4. (1-HR FIRE RATED EXTERIOR WALLS)
708 FIRE PARTITIONS
708.1 THE FOLLOWING WALL ASSEMBLIES SHALL COMPLY WITH THIS SECTION:1. WALLS SEPARATING DWELLING UNITS IN THE SAME BUILDING PER 420.22. N/A3. CORRIDOR WALLS AS REQUIRED BY 1020.1.4. ELEVATOR LOBBIES: NOT REQUIRED BY SECTION 3006.25. N/A
708.3 FIRE PARTITIONS SHALL HAVE A FIRE RESISTANCE RATING OF NOT LESS THAN 1 HR.
EXCEPTION 1: CORRIDOR WALLS PERMITTED TO HAVE 1/2-HOUR RESISTANCERATING AS PERMITTED BY TABLE 1020.1 (SPRINKLERED BUILDING)
711 HORIZONTAL ASSEMBLIES
705.5 REQUIRED FIRE RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPARATIONDISTANCE GREATER THAN 10' SHALL BE RATED FOR EXPOSURE FROM THE INSIDE.
REQUIRED FIRE RESISTANCE RATING OF EXTERIOR WALLS WITH A FIRE SEPARATIONDISTANCE OF LESS THAN OR EQUAL TO 10' SHALL BE RATED FOR EXPOSURE FROMBOTH SIDES.
15% NOLIMITNO
LIMIT
711.2.3 SUPPORTING CONSTRUCTION SHALL BE RATED THE SAME AS THE SUPPORTEDHORIZONTAL ASSEMBLY.
EXCEPTIONS: IN TYPE VB CONSTRUCTION, CONSTRUCTION SUPPORTINGHORIZONTAL ASSEMBLIES SEPARATING DWELLING UNITS (420.3) NEED NOT BETHE SAME AS THE SUPPORTED ASSEMBLY.
711.2.4.3 HORIZONTAL ASSEMBLIES SEPARATING DWELLING UNITS SHALL BE 1-HR FIRERATED. EXCEPTION: REDUCED TO 1/2-HR IN BUILDINGS EQUIPPED WITHAUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 903.3.1.1.
713 SHAFT ENCLOSURES 713.2 SHAFTS SHALL BE CONSTRUCTED AS FIRE BARRIERS.713.4 SHAFT ENCLOSURE: 2-HR FIRE RATED WHEN CONNECTING 4 STORIES OR MORE
1-HR FIRE RATED WHEN CONNECTING LESS THAN 4 STORIES
CODE REF. DESCRIPTION
CHAPTER 9 - FIRE PROTECTION AND ALARM SYSTEMS
1. CONTRACTOR SHALL PROVIDE FIRE PROTECTIVE SIGNALING SYSTEM ANDAUTOMATIC FIRE DETECTION SYSTEM AS REQUIRED BY 780 CMR THEMASSACHUSETTS STATE BUILDING CODE 9th EDITION (2015 IBC), AS AMENDEDBY THE MASSACHUSETTS AMENDMENTS TO THE IBC, AND AS REQUIRED BY THEINTERNATIONAL FIRE CODE, LOCAL ORDINANCES, AND AS INDICATED ON THECONTRACT DOCUMENTS.
2. CONTRACTOR SHALL PROVIDE CARBON MONOXIDE DETECTORS AS REQUIRED BY780 CMR THE MASSACHUSETTS STATE BUILDING CODE 9th EDITION (2015 IBC),AS AMENDED BY THE MASSACHUSETTS AMENDMENTS TO THE IBC, 527 CMR31.00 AND AS INDICATED IN THE CONTRACT DOCUMENTS.
CODE REF. DESCRIPTION
521 CMR - MASSACHUSETTS ARCHITECTURAL ACCESS BOARD
9.2 APPLICABILITY
NEW CONSTRUCTION OF MULTIPLE DWELLINGS SHALL MEET THE REQUIREMENTS OFSECTION 9.3 GROUP 1 UNITS, AND SECTION 9.4 GROUP 2 UNITS WHERE REQUIRED.
9.3 ALL GROUP 1 DWELLING UNITS SHALL COMPLY WITH SECTION 9.5, AND SECTION 42GROUP 1 BATHROOMS, SECTION 43 GROUP 1 KITCHENS, AND SECTION 44 GROUP 1BEDROOMS.
9.4 GROUP 2 UNITS: NONE REQUIRED THIS PROJECT. (FEWER THAN 20 UNITS, ALL UNITSFOR SALE.
CODE REF. DESCRIPTION
CHAPTER 13: ENERGY EFFICIENCY ENERGY CONSERVATION
APPLICABILITY
1300.1 PER MASS AMENDMENT 1301.1.1 CRITERIA, BUILDINGS SHALL COMPLY WITH THEIECC 2015 , AS AMENDED BY 780 CMR 13.00.
THE BUILDING IS LOCATED IN BOSTON, A MUNICIPALITY WHICH HAS ADOPTED THESTRETCH ENERGY CODE, 780 CMR, APPENDIX AA STRETCH ENERGY CODE.
AA103 NEW BUILDINGS: IN ALL R-USE BUILDINGS, OF 4 STORIES OR FEWER ABOVE GRADEPLANE, EACH DWELLING UNIT SHALL COMPLY WITH SECTION N1106 OF 780 CMR51.00: MASSACHUSETTS RESIDENTIAL CODE .
N1106 PER THIS SECTION OF 780 CMR 51.00, AS AMENDED, MAXIMUM HERS RATING SHALLBE 55.
MINIMUM REQUIREMENTS
MINIMUM REQUIREMENTS
MINIMUM REQUIREMENTS
MINIMUM REQUIREMENTS CONTRACTOR SHALL TAKE ALL MEASURES REQUIRED TO KEEP DUST,DEBRIS, NOISE, AND DISTURBANCE TO A MINIMUM.
GENERAL NOTESALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE STATEBUILDING CODE OF MASSACHUSETTS AND ALL LOCAL ORDINANCES.
CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS.
CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ARCHITECT FORREVIEW PRIOR TO ORDERING OR FABRICATION OF WORK. NO WORKSHALL PROCEED WITHOUT ARCHITECT'S APPROVAL.
DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SHALL HAVEPRECEDENCE. IN THE EVENT OF CONFLICT IN DIMENSIONS, CONTACTTHE ARCHITECT FOR CLARIFICATIONS.
u
A a
t
374 CONGRESS STREETBOSTON, MA 02210-1807TEL: (617) 423-1022FAX: (617) 426-0939email: [email protected]
NEW MULTI-FAMILY DWELLING
874 EAST 6th STREETSOUTH BOSTON, MA 02127
ARCHITECT'S PROJECT NO. 16-297
16-297NEW MULTI-FAMILY DWELLING874 E. 6th STREETSOUTH BOSTON, MA 02127
DATE DESCRIPTION
CONTEXT PLAN - SOUTH BOSTONNO SCALE
PROJECTLOCATION
NORTH
E. 6th STREET
LEN
NO
N C
T FARR
AGUT
RO
AD
WILLIAM J DAY BLVD
P ST
REET APRIL 18, 2017 INITIAL FILE for PERMIT
JUNE 20, 2018 ZONING BOARD of APPEALBUILDING PERMIT
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEER
ZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEER
PROMETHEUS LIFE SAFETY17 MILL RUN RD.BOXFORD MA
ERT # 698417
APRIL 03, 2019GENERAL REVISION:RAISE BUILDING/ BPDA REVIEW
MARCH 19, 2020
MAY 15, 2020 RAISE GROUND FLOOR TO EL 17'-6"AND RE-ISSUE
DESCRIPTIONCODE REF.
CORRIDORS: MINIMUM WIDTH 44", OR 36"WHEN SERVING AN OCCUPANCYOF LESS THAN 50
EGRESS DOORS MIN WIDTH 32" (1)
EGRESS WIDTH PER OCCUPANT
STAIRWAYS: MINIMUM WIDTH 44", OR 36"WHEN SERVING AN OCCUPANCY OFLESS THAN 50 (EXCEPTION 1)
OTHER EGRESS COMPONENTS .2"/OCCMINIMUM STAIR WIDTH .3"/OCC
EGRESS COMPONENT - MINIMUM WIDTHS
PARKING 200 SF/OCC
OCCUPANCY LOAD
NOTES:(1) 36" DOOR OPENING WITH CLEAR OPENING WIDTH OF 33"
RESIDENTIAL 200 SF/OCC
1010.1.1
TABLE1004.1.2
1020.2
1011.2
1005.3.1
EGRESS COMPONENTS
1005.3.2
PROVIDED EGRESS WIDTH (INCHES)REQUIRED EGRESS WIDTH (INCHES)
EXIT STAIR NO.OCCUPANT LOAD
0000
EXIT ID.00
0000
STAIRDOOR
2-HR RATED1-HR RATED
PATH TO EXIT
PROVIDED EGRESS WIDTH (INCHES)REQUIRED EGRESS WIDTH (INCHES)OCCUPANT LOADEXIT NO.EXIT ID.
LEGEND
0000
00
EXIT
END OF COMMON PATH OF EGRESS TRAVEL
NUMBER OF EXITSONLY ONE EXIT PER FLOOR IS REQUIRED FOR THE GROUND FLOOR ANDRESIDENTIAL FLOOR 1 AND 2, PER THE FOLLOWING.RESIDENTIAL FLOOR 3 REQUIRES 2 EXITS.
R-2 RESIDENTIAL OCCUPANCY FLOORS 1 AND 2:PER TABLE 1006.3.2(1), ONE EXIT PER STORY IS PERMITTED IN:- R-2 OCCUPANCIES- BASEMENTS, FIRST, SECOND AND THIRD STORIES ABOVE GRADE PLANE- 125' MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE- AUTOMATIC SPRINKLER SYSTEM PER NFPA 13 OR NFPA 13R.- EMERGENCY ESCAPE AND RESCUE OPENINGS IN BEDROOMS.
S-2 VEHICLE PARKING OCCUPANCY:PER TABLE 1006.3.2(2), ONE EXIT PER STORY IS PERMITTED IN:- S OCCUPANCIES- FIRST STORY ABOVE OR BELOW GRADE PLANE- MAXIMUM 29 OCCUPANTS PER STORY- 75' MAXIMUM COMMON PATH OF EGRESS TRAVEL DISTANCE (NFPA 13R)
THE PROPOSED PROJECT MEETS ALL OF THE ABOVE REQUIREMENTS FORGROUND FLOOR, 1st AND 2nd FLOORS.
3rd FLOOR IS THE 4th STORY ABOVE GRADE PLANE, THEREFORE TWOEXISTS ARE REQUIRED. TWO EXITS ARE INDICATED.
FIRE RATINGSAT A MINIMUM, PROVIDE THE FOLLOWING FIRE RATINGS(CONSTRUCTION TYPE VA):
EXTERIOR WALLS LESS THAN 10' FIRE SEPARATION: 1-HR ALL SUCH WALLS SHALL BE FIRE RATED FROM INTERIOR
AND EXTERIOR
EXTERIOR WALLS 10' AND LESS THAN 30' FIRE SEPARATION:1-HR
ALL SUCH WALLS SHALL BE FIRE RATED FROMINTERIOR SIDE ONLY
STAIRWAY SERVES 4 STORIES: 2-HR
STAIRWAY SERVING 3 STORIES: 1-HR
SEPARATION BETWEEN DWELLING UNITS: 1-HR
IN ADDITION, PROVIDE FIRE RATINGS AS INDICATED FORWALL AND PARTITION TYPES
BALCONY
BALC
UPDN
DN
UP
L1
L3
L2
L4
L C
AR
C
gov
BALCONY
BALC
UPDN
DN
CL
UPDN
BALCONY
BALC
UP
DN
SHOWER36x48
BALCONY
UPDN
DN
UP
L1
L3
L2
L4
L C
AR
C
gov
BALCONY
BALC
UPDN
DN
CL
EXIT
SEP
RATI
ON
33'
= 1
/3 D
IAG
ON
AL D
IMEN
SIO
N O
F AR
EA S
ERVE
D
UPDN
BALCONY
BALC
UP
DN
SHOWER36x48
SPACE FOR VEHICLEMANUEVERABILITY
UP
PRO
PERT
Y LI
NE
(TYP
)
LANDSCAPE
UP
PUBLIC SIDEWALK
LEVEL OF EXIT DISCHARGE
EAST 6th STREET
EXTERIORDRIVEWAY
123
4
5
6
7
8
9
PARKING
MOSTREMOTEPOINT INGARAGE
ELEV
BEDROOM BEDROOM
ERER
UNIT 23 BR BEDROOM
MOST REMOTE POINTDISTANCE TO EXIT = ±71'(CODE MAX 125')
ELEV
ER
ER
UNIT 12 BR
BEDROOM
BEDROOM
UNIT 43 BR
UNIT 32 BR
MOST REMOTE POINTDISTANCE TO EXIT = ±90'(CODE MAX 125')
STAIR 1
STAIRWAY 1
BEDROOM BEDROOM
MOST REMOTE POINTDISTANCE TO EXIT = ±70'(CODE MAX 125')
BEDROOM
BEDROOM
BEDROOM
ER ER
ER
ER
ER
STAIRWAY 2
STAIR2
UNIT 63 BR
UNIT 52 BR
BEDROOM BEDROOM
BEDROOM
BEDROOM
MOST REMOTE POINTDISTANCE TO EXIT = ±70'(CODE MAX 125')
PROPERTY LINE (TYP)
PRO
PERT
Y LI
NE
(TYP
)
PROPERTY LINE (TYP)
ER ER
ER
ER
FRONTSTAIR
DOOR STAIRWIDTH REQUIRED 32" 36"WIDTH PROVIDED 33" 44"
OCC LOAD =19BASED ON 2nd FLOOR
REAR STAIR(FOR 3rd FLR)DOOR STAIR
WIDTH REQUIRED 32" 36"WIDTH PROVIDED 33" 36"
FRONTSTAIR
DOOR STAIRWIDTH REQUIRED 32" 36"WIDTH PROVIDED 33" 44"
OCC LOAD =19BASED ON 2nd FLOOR
MECH
ELEV
FRONTSTAIR
DOOR STAIRWIDTH REQUIRED 32" 36"WIDTH PROVIDED 33" 44"
OCC LOAD =19BASED ON 2nd FLOOR
STAIR 1
MECH
MOST REMOTE POINTDISTANCE TO EXIT = ±90'(CODE MAX 125')
MOST REMOTE POINTDISTANCE TO EXIT = ±90'(CODE MAX 125')
FRONTDOOR
WIDTH REQUIRED 32"WIDTH PROVIDED 33"
OCC LOAD =19BASED ON 2nd FLOOR
REAR STAIR(FOR 3rd FLR)DOOR STAIR
WIDTH REQUIRED 32" 36"WIDTH PROVIDED 33" 36"
REAR STAIR(FOR 3rd FLR)DOOR STAIR
WIDTH REQUIRED 32" 36"WIDTH PROVIDED 33" 36"
OCC LOAD =10HALF OF TOTAL LOADFOR THIS FLOOR
OCC LOAD =10HALF OF TOTAL LOADFOR THIS FLOOR
OCC LOAD =10HALF OF TOTAL LOADFOR THIS FLOOR
DIAGONAL DIMENSION OF FLOOR AREA SERVED = ±99'EXIT SEPARATION REQUIRED = 1/3 X 75' = 33'EXIT SEPARATION PROVIDED AT 3rd FLOOR = 33'
EAST
6th
ST.
AVG GRADE(ZONING)EL. 16.77'
39'-
11"
BUIL
DIN
G H
EIG
HT
(ZO
NIN
G C
OD
E)
EAST 6th STREET
9'-1
0"9'
-10"
9'-1
0"9'
-8"
2nd FLOOR
1st FLOOR
ROOF
3rd FLOOR
GROUND FLREL. 17'-6"
CALCULATED GRADE PLANE EL. 17.45'
EL. 17'-6" (17.5')
EL. 17'-6" (17.5')RIGHT SIDE B (LEVEL±)
39'-10 (39.8')
262'
GRADE PLANE CALCULATION PER 502.1
ELEVATIONAVERAGE GRADEAT BUILDING SIDE X LENGTH =
FRONT 36'-0" (36.0')EL. 16'-9" (16.77')
EL. 17'-6" (17.5') 95'-0" (95.0')LEFT SIDE
REAR EL. 17'-6" (17.5')
RIGHT SIDE A (SLOPING)
1662.50'
980.00'
630.00'
56'-0" (56.0')
EL X L
603.72'
4,572.72' / 262'= EL. 17.453'
696.50'
TOTAL PERIMETER
36'-0" (36.0')
REVISED WITH BUILDING RAISED:
FINISH FLOOR AT 1st FLOOR = EL. 27.33'GRADE PLANE = EL. 17.45'
1st FLOOR ABOVE GRADE PLANE = EL. 9.88'
PER CHAPTER 2 DEFINITIONS, THE FINISH SURFACE OF THE 1st FLOORIS MORE THAN 6 FEET ABOVE GRADE PLANE.THEREFORE, GROUND FLOOR IS A STORY ABOVE GRADE PLANE, ANDTHE PROPOSED BUILDING IS A 4-STORY BUILDING 1
GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
WAP AMP
A0.0
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
EGRESS PLANS
3/32" = 1'-0"
G R O U N D F L O O R P L A N1st F L O O R P L A N3/32" = 1'-0"
2nd F L O O R P L A N3/32" = 1'-0"
G R A D E P L A N E & B U I L D I N G H E I G H T D I A G R A M3/32" = 1'-0"
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
04/03/19 FOR PERMIT
3rd F L O O R P L A N3/32" = 1'-0"
RAISE BLDG / BPDA1 03/19/20RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
TREADS
TOGGLE BOLT
TROWELLED CONCRETE
TERRAZZO
TONGUE AND GROOVE
TEMPERED GLASS
THICK
TOP OF CONCRETE
TOP OF MASONRY
TOP OF STEEL
TOP OF WALL
TYPICAL
UNGLAZED CERAMIC TILE
UNLESS OTHERWISE NOTED
UTILITY
VINYL
VINYL WALL COVERING
VAPOR BARRIER
VINYL COMPOSITION TILE
VERTICAL
VERIFY IN FIELD
WEST
WOOD BASE
WOOD
WITH/
WITHOUT
WIRED GLASS
WORKING POINT
WIDTH
ABBREVIATIONS
TERMPROVIDECONTRACTORINDICATED
DEFINITIONS
@
AB
ACOUST
ACT
AD
ADJ
AFF
AISC
AL
ANOD
ARCH'T
ASSOC
AWI
B
BLDG
BLKG
BLW
BOT
BP
BR
BRK
BRZ
BUR
CL
CAB
CARP
CB
CG
CHR
CI
CJ
CLG
CL
CMU
COL
CONC
CONT
CONV
COP
CT
PARALLEL
PARTICLE BOARD
PERPENDICULAR
PLATE
PLASTIC LAMINATE
PLASTER
PLASTIC
PLYWOOD
PANEL
PRESSED METAL
PORCELAIN TILE
PAINTED
PAINTED GYPSUM WALL BD.
PRESSURE TREATED LUMBER
PAPER TOWEL DISPOSAL UNIT
PAVING
POLY VINYL CHLORIDE
QUARRY TILE
RADIUS OR RISERS
ROOF DRAIN
REFER OR REFERRED
REINFORCED OR REINFORCING
REQUIRED
ROOM
ROUGH OPENING
SOUTH
SCREW
SECTION
SQUARE FOOT
SIMILAR
SANITARY NAPKIN DISPOSAL
SANITARY NAPKIN VENDING
SPECIFICATIONS
SPRINKLER
SQUARE
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STRUCTURAL
SUSPENDED
SWITCH
SQUARE YARD
SHEET VINYL FLOORING
SURFACE FOUR SIDES
PAR
PART BD
PERP
PL
P LAM
PLA
PLAS
PLYWD
PNL
PM
PT
PTD
PTD GWB
PTL
PTDU
PV
PVC
QT
R
RD
REF
REINF
REQ'D
RM
RO
S
SCR
SECT
SF
SIM
SND
SNV
SPEC
SPKLR
SQ
SS
STD
STL
STOR
STR
SUSP
SW
SY
SVF
S4S
HB
HGT
HM
HOR
HP
HVAC
HW
HYD
ID
INSUL
INST
INT
JAN
LAM
LAV
LC
LF
LP
LVR
MACH
MAX
MECH
MF
MFG
MH
MIN
MISC
MO
MR
MT
MTL
N
NIC
NOM
NP
NTS
OA
OC
OD
OH
OPG
OPP
DEPTH
DETAIL
DRINKING FOUNTAIN
DIAMETER
DIMENSION
DOWN
DITTO
DOOR
DRAWING
EAST
EACH
EXPANSION BOLT
EXPANSION JOINT
ELECTRICAL
ELEVATION
EQUAL
EQUIPMENT
ELECTRICAL WATER COOLER
EXISTING
EXPOSED
EXTERIOR
FIRE ALARM
FLOOR DRAIN
FIRE EXTINGUISHER
FABRIC FLASHING
FINISHED
FLOOR
FINISHED OPENING
FIREPLACE
FIRE RESISTANT
FRAMING
FIBER REINFORCED PLASTIC
FOOTING
GAUGE
GALVANIZED
GLASS BLOCK
GENERAL CONTRACTOR
GLASS
GRADE
GYPSUM WALL BOARD-PTD
GROUND FLOOR
D
DET
DF
DIA
DIM
DN
DO
DR
DWG
E
EA
EB
EJ
ELEC
ELEV
EQ
EQUIP
EWC
EXIST
EXP
EXT
FA
FD
FE
FF
FIN
FLR
FO
FP
FR
FRM'G
FRP
FTG
GA
GALV
GB
GC
GL
GR
GWB
GR FLR
AT
ANCHOR BOLT
ACOUSTIC
ACOUSTIC CEILING TILE
ACCESS DOOR
ADJACENT
ABOVE FINISH FLOOR
AMERICAN INSTITUTE OFSTEEL CONSTRUCTION
ALUMINUM
ANONDIZED
ARCHITECT
ASSOCIATE
AMERICAN WOODWORKINSTITUTE
BASE
BUILDING
BLOCKING
BELOW
BOTTOM
BUILDING PAPER
BRASS
BRICK
BRONZE
BUILT UP ROOF
CENTER LINE
CABINET
CARPET
CATCH BASIN
CORNER GUARD
CHROME
CAST IRON
CONTROL JOINT
CEILING
CLEAR (DIM)
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONTINUOUS
CONVECTOR
COPPER
CERAMIC TILE
HOSE BIB
HEIGHT
HOLLOW METAL
HORIZONTAL
HIGH POINT
HEATING, VENTILATION &AIR CONDITIONING
HOT WATER
HYD
INSIDE DIAMETER
INSULATION
INSTALL (ed)
INTERIOR
JANITOR
LAMINATE
LAVATORY
LEAD COATED
LINEAR FEET
LOW POINT
LOUVER
MACHINE
MAXIMUM
MECHANICAL
METAL FLASHING
MANUFACTURER
MANHOLE
MINIMUM
MISCELLANEOUS
MASONRY OPENING
MOISTURE RESISTANT
MARBLE THRESHOLD
METAL
NORTH
NOT IN CONTRACT
NOMINAL
NEOPRENE
NOT TO SCALE
OVERALL
ON CENTER
OUTSIDE DIAMETER
OVERHEAD
OPENING
OPPOSITE
GENERAL CONTRACTOR AND ITS SUB-CONTRACTORSAS DESCRIBED ON CONTRACT DOCUMENTS
DEFINITIONFURNISH AND INSTALL
T
TB
TC
TERR
T&G
TGL
THK
TOC
TOM
TOS
TOW
TYP
UNG
UON
UTIL
V
VWC
VB
VCT
VERT
VIF
W
WB
WD
W/
W/O
WGL
WP
WTH
301
3068
A9.1
18
A3.1
A7.1
A3.1
1
6
3
4
1
25
7
A
3
8
WINDOW TYPE
DOOR DIMENSIONS
HEIGHT FEET INCHES (6'-8")
WIDTH FEET INCHES (3'-0")
WALL ELEVATION
EQUIPMENT NUMBER
REVISION KEY
2
BUILDING SECTION
DETAIL INDICATION
WALL SECTION
SPACE NUMBER
DOOR NUMBER
PARTITION TYPE
SECT.LETTERDWG. NO.
DWG. NO.SECT. NO.
DWG. NO.DET. NO.
GRAPHIC SYMBOLS
COLUMN LINE
ELEVATION SPOTTER
(OR SEE DOOR SCHEDULE)
FINISH WOOD
WOOD BLOCKING (ROUGH)
POROUS FILL
CONCRETE
CONCRETE MASONRY UNIT(CMU)
STEEL
EARTH
BRICK
EXISTING TO REMAIN
NEW PARTITION
MATERIAL SYMBOLS
GENERAL NOTES
PROJECT NOTES
1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE MASSACHUSETTS STATE BUILDING CODEAND ALL APPLICABLE REQUIREMENTS OF THE CITY OF BOSTON. WORK ON THIS PROJECT SHALL BECOMPLETED IN ACCORDANCE WITH THE STATE ENERGY CODE.
2. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO THECOMMENCEMENT OF THE WORK AND FABRICATION OF MATERIALS. IF A CONFLICT ARISES BETWEEN ANEXISTING CONDITION AND THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL IMMEDIATELY NOTIFYTHE ARCHITECT FOR DIRECTION.
3. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL PRIOR TO ORDERING,FABRICATION OR INSTALLATION OF ALL WORK. NO WORK SHALL PROCEED WITHOUT ARCHITECT'S REVIEWAND APPROVAL.
4. THE CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY SHORING, DUST AND WEATHER PROTECTIONTHROUGHOUT THE ENTIRE PROJECT.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS, INCLUDING, BUT NOTLIMITED TO BUILDING, ELECTRICAL, HVAC, PLUMBING AND THOSE REQUIRED THE CITY OF BOSTON FIREDEPARTMENT.
6. UNLESS OTHERWISE NOTED, CONCRETE USED TO BE 4,000 PSI AFTER 28 DAYS. ALL CONCRETE WORKIS TO BE PERFORMED IN ACCORDANCE WITH ACI AND ASTM STANDARD REQUIREMENTS.
PROJECT NOTESGENERAL:1. THE CONTRACTOR SHALL PROVIDE A FULLY-FUNCTIONING COMPLETE PROJECT ACCEPTABLE TO THEOWNER AND COMPLYING WITH ALL APPLICABLE CODES. OBTAIN APPROVALS FROM ALL AUTHORITIESHAVING JURISDICTION.2. IF REQUIRED BY AUTHORITIES HAVING JURISDICTION, PREPARE AND SUBMIT DOCUMENTATION ASREQUESTED AND AS REQUIRED TO SECURE APPROVALS.3. CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS. OBTAIN OCCUPANCY PERMIT AT COMPLETIONOF THE WORK.4. CONTRACTOR AND SUBCONTRACTORS SHALL WARRANTY THE WORK FOR ONE (1) YEAR FROM DATEOF OWNER'S FINAL ACCEPTANCE.5. BEFORE CONSTRUCTION, VERIFY THE LOCATION AND INVERT ELEVATION AT POINTS OF CONNECTIONOF SANITARY SEWER, STORM WATER AND WATER SERVICE PIPING. VERIFY LOCATION OF GAS PIPING ANDUNDERGROUND ELECTRICAL SERVICES. OBTAIN ALL REQUIRED APPROVALS.6. CONFORM WITH ALL CITY ORDINANCES WITH REGARD TO PROJECT AREA ACCESS, DEBRIS REMOVALAND DISPOSAL, HOURS OF OPERATION, NOISE, DUMPSTER LOCATION AND ALL RULES AND RESTRICTIONSAPPLICABLE TO DEMOLITION AND CONSTRUCTION WORK.7. ADJACENT BUSINESSES, OFFICES AND DWELLINGS WILL BE OCCUPIED FOR DURATION OF PROJECT.TAKE EXTREME CARE TO NOT DISRUPT NORMAL USE OF THE ADJACENT PROPERTIES BY THE OCCUPANTS.8. GENERAL CONTRACTOR SHALL EMPLOY LICENSED AND QUALIFIED SUBCONTRACTORS TO PROVIDEALL WORK REQUIRED FOR A FULLY-FUNCTIONING PROJECT IN COMPLIANCE WITH THE CONTRACTDOCUMENTS, WITH THE STATE BUILDING CODE AND ALL LOCAL CODES AND ORDINANCES.9. PROVIDE ENGINEERING SERVICES AS REQUIRED TO OBTAIN ALL REQUIRED PERMITS AND FOR THECOMPLETION OF A FULLY-FUNCTIONING PROJECT.10. CONTRACTOR SHALL INCLUDE ALL COSTS FOR THE ABOVE IN THE BID.
INSTALLATION:1. EXAMINE WALLS, FLOORS AND ROOFS FOR SUITABLE CONDITIONS WHERE PRODUCTS AND SYSTEMSARE TO BE INSTALLED. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVEBEEN CORRECTED.2. RUN ALL MECHANICAL AND ELECTRICAL ABOVE CEILING HEIGHTS AS INDICATED. SOFFITING IS ONLYPERMITTING WHERE NO OTHER OPTION IS AVAILABLE AND AS APPROVED BY ARCHITECT IN ADVANCE.3. TAKE FIELD MEASUREMENTS AS REQUIRED TO FIT THE WORK PROPERLY.4. VERIFY SPACE REQUIREMENTS AND DIMENSIONS OF ITEMS SHOWN DIAGRAMMATICALLY ONDRAWINGS PRIOR TO FABRICATION OR PURCHASE.5. VERIFY ROUGH OPENING REQUIREMENTS OF DOORS AND WINDOWS AS ACTUALLY SELECTED FOR USEON PROJECT BEFORE FRAMING. MAKE ALL ADJUSTMENTS AS REQUIRED.6. ALL VERTICAL WORK SHALL BE PLUMB AND ALL HORIZONTAL WORK SHALL BE LEVEL.7. DO NOT OVERLOAD FLOORS OR ROOFS.8. COORDINATE THE CONNECTION OF MECHANICAL SYSTEMS WITH EXTERIOR UNDERGROUND ANDOVERHEAD UTILITIES AND SERVICES. PROVIDE REQUIRED CONNECTION FOR EACH SERVICE. COMPLY WITHREQUIREMENTS OF AGENCIES AND AUTHORITIES HAVING JURISDICTION.9. COORDINATE INSTALLATION AND CONNECTION OF TELEPHONE, INTERNET, AND CABLE TV SERVICES.10. INSTALL EQUIPMENT TO PROVIDE THE MAXIMUM HEADROOM POSSIBLE.11. INSTALLATION OF MATERIALS AND EQUIPMENT SHALL COMPLY WITH MANUFACTURER'S WRITTENINSTRUCTIONS AND RECOMMENDATIONS.12. DO NOT CUT STRUCTURAL MEMBERS IN A MANNER WHICH AFFECTS THE STRUCTURAL CAPACITY OFTHE MEMBER. ALL PENETRATIONS OF STRUCTURAL MEMBERS SHALL COMPLY WITH THE MASSACHUSETTSSTATE BUILDING CODE AND WITH STRUCTURAL MEMBER MANUFACTURER'S REQUIREMENTS.13. WHEN TORCH CUTTING OR WELDING, MAINTAIN FIRE WATCH AS REQUIRED BY LOCAL FIREDEPARTMENT REGULATIONS.14. DO NOT MODIFY COMPONENTS IN A MANNER WHICH WILL REDUCE THEIR CAPACITY TO PERFORM ASINTENDED, INCLUDING BUT NOT LIMITED TO WEATHER, AIR AND MOISTURE BARRIERS; VAPOR RETARDERS;ACOUSTIC CONTROLS; MEMBRANES AND FLASHINGS.15. CLEAN THE PROJECT SITE AND WORK AREA DAILY. DISPOSE OF DEBRIS IN ACCORDANCE WITH ALLAPPLICABLE REGULATIONS.16. CLEAN ALL SURFACES AND PROTECT AS REQUIRED UNTIL FINAL ACCEPTANCE BY OWNER.17. REMOVE AND REPLACE ANY BROKEN OR DAMAGED GLASS.
KITCHENS:1. KITCHEN CABINETS AND PLUMBING FIXTURES AND FITTINGS AS SELECTED BY OWNER.2. KITCHEN APPLIANCES AS SELECTED BY OWNER.3. PROVIDE ALL DIMENSIONS AND CONDITIONS IN THE FIELD AS REQUIRED FOR THE PROPERINSTALLATION OF ALL APPLIANCES. COORDINATE IN ADVANCE WITH THE OWNER.4. CONTRACTOR SHALL INCLUDE COST TO FURNISH AND INSTALL ALL KITCHEN CABINETS, APPLIANCES,FIXTURES AND FITTINGS. IF SUCH ITEMS HAVE NOT BEEN SELECTED OR DETAILED, CONTRACTOR SHALLCARRY A REASONABLE ALLOWANCE IN THE BID FOR ALL SUCH ITEMS.
BATHROOMS:1. PLUMBING FIXTURES, FITTINGS AND BATHROOM ACCESSORIES SHALL BE AS INDICATED ANDSELECTED BY THE OWNER.2. VANITY AND STORAGE MILLWORK AS INDICATED AND AS SELECTED BY OWNER.3. CONTRACTOR SHALL INCLUDE COST TO FURNISH AND INSTALL ALL BATHROOM CABINETS, FIXTURESAND FITTINGS. IF SUCH ITEMS HAVE NOT BEEN SELECTED OR DETAILED, CONTRACTOR SHALL CARRY AREASONABLE ALLOWANCE IN THE BID FOR ALL SUCH ITEMS.
PLUMBING:1. CONTRACTOR SHALL PROVIDE ALL PLUMBING AS REQUIRED BY THE PROJECT.2. INSTALL ALL FIXTURES AND APPLIANCES INCLUDING THOSE FURNISHED BY OWNER.2. ALL NEW PIPING SHALL BE CONCEALED IN THE FINISHED WORK. ALL HOT AND COLD PIPING SHALL BEINSULATED. SOLIDLY ANCHOR PIPING TO FRAMING. PROVIDE EXPANSION CONTROL TO ELIMINATE NOISE.3. SANITARY PIPING SHALL BE CAST IRON.
HVAC:1. PROVIDE HEATING, COOLING AND VENTILATION SYSTEMS AS REQUIRED BY CODE AND OWNER.2. PROVIDE HVAC EQUIPMENT IN SPACES INDICATED IN UNITS AND BUILDING MECHANICAL ROOMS.3. ALL WORK SHALL BE CONCEALED.4. AVOID SOFFITING OF DUCTWORK.
ELECTRICAL:1. CONTRACTOR SHALL PROVIDE COMPLETE ELECTRICAL WORK AS REQUIRED FOR THE PROJECT.PROVIDE A FULLY-FUNCTIONING COMPLETE PROJECT COMPLYING WITH ALL APPLICABLE CODES ANDAPPROVED BY ALL AUTHORITIES HAVING JURISDICTION.2. PROVIDE ALL LIGHTING INCLUDING EXTERIOR LIGHT, LANDSCAPE LIGHTING AND INTERIOR ANDEXTERIOR SECURITY LIGHTING.3. ALL WIRING, CONDUIT, JUNCTION BOXES ETC. SHALL BE CONCEALED IN THE FINISHED WORK.4. DO NOT LOCATE DEVICES BACK-TO-BACK ON OPPOSITE SIDES OF SAME PARTITION. SEPARATE SUCHDEVICES BY ONE STUD BAY MINIMUM.5. LIGHT FIXTURES AS SELECTED BY OWNER.6. COORDINATE THE INSTALLATION AND CONNECTION OF ALL APPLIANCES.7. SUBMIT ALL EXPOSED-TO-VIEW ITEMS TO OWNER FOR APPROVAL PRIOR TO PURCHASE ANDINSTALLATION.
FIRE PROTECTION SYSTEMS:1. PROVIDE FIRE PROTECTIONS SYSTEM AS INDICATED, AND AS REQUIRED BY CODE AND AUTHORITIESHAVING JURISDICTION.
FIRE DETECTION AND ALARM SYSTEMS:1. PROVIDE FIRE ALARM SYSTEM AS INDICATED, AND AS REQUIRED BY CODE AND AUTHORITIES HAVINGJURISDICTION.2. PROVIDE SMOKE, HEAT AND CARBON MONOXIDE DETECTORS AS INDICATED, AND AS REQUIRED BYCODE AND AUTHORITIES HAVING JURISDICTION.
ENERGY CONSERVATION:1. PROVIDE FINISHED PROJECT WHICH COMPLIES WITH THE ENERGY CONSERVATION REQUIREMENTS OFTHE STATE BUILDING CODE AND LOCAL REQUIREMENTS.2. PROVIDE AND DEMONSTRATE COMPLIANCE WITH STATE OF MASSACHUSETTS STRETCH CODE.3. OWNER SHALL ENGAGE HERS RATER TO PERFORM ALL REQUIRED INSPECTIONS AND TESTING, ANDWHO SHALL ALSO SUBMIT ALL REQUIRED DOCUMENTATION TO LOCAL BUILDING OFFICIALS.
STORM WATER/GROUND WATER:1. PROVIDE STORM WATER AND GROUND WATER CONTROL SYSTEMS AS DETERMINED AND AS DESIGNEDBY OWNER'S CIVIL AND SOILS ENGINEER. ABBREVIATIONS,
SYMBOLS, NOTES
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
A0.1
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
AMP AMP
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
04/03/19 FOR PERMIT1 RAISE BLDG / BPDA03/19/20
RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
58"
634"
58"
338" 33
8" 238"
434"
58" 5
8"
UL DES U3051-HR FIRE RATED
STC 46BBN-700725
2 X 6 WD STUD@ 16" O.C.
512" 31
2"
4
UL DES U3011-HR FIRE RATED/2-HR FIRE RATED
STC 58USG-810219
STUDLCLC
INTERIOR PARTITIONLOAD BEARING / NON-LOAD BEARING3 1
5/8" GWB TYPE XFIRECODE GWBTYP EACH SIDE
2 X 4 WD STUDS@ 16" O.C.
UL DES U3051-HR FIRE RATED
STC 46BBN-700725
1 1/2" = 1'-0"PARTITION TYPES/WALL TYPES
PLAN VIEW UNLESS OTHERWISE NOTED
238"
TYPICAL PARTITION WITHINDWELLING UNIT SHALL BE TYPE 1.
STUD
5/8" GWB TYPE XFIRECODE GWBTYP EACH SIDE
3" USGTHERMAFIBERSAFB
INTERIOR PARTITIONLOAD BEARING / NON-LOAD BEARING
3"3"
114"
2 LAYERS5/8" GWB TYPE XFIRECODE GWBTYP EACH SIDE
6"
2 X 4 WD STUD@ 16" O.C.
3" USGTHERMAFIBERSAFB
312" 11
4"
LC
INTERIOR PARTITIONLOAD BEARING / NON-LOAD BEARING2
STUD
114"51
2"114"
8"
3" USGTHERMAFIBERSAFB
CLSTUD
2 X 6 WD STUD@ 16" O.C.
4"4"
2 LAYERS5/8" GWB TYPE XFIRECODE GWBTYP EACH SIDE
INTERIOR PARTITIONLOAD BEARING / NON-LOAD BEARING
NOTES:1. UNKEYED PARTITIONS SHALL BE SAME AS KEYED PARTITIONS IN SIMILAR LOCATIONS AS DETERMINED BY ARCHITECT.2. SAFB = SOUND ATTENTUATION FIRE BLANKET. USG THERMAFIBER MINERAL WOOL, ROXUL STONE WOOL OR EQ.3. AT WALLS TO BE TILED, PROVIDE 1/2" DUROCK BELOW TILE IN LIEU OF GWB.4. AT INTERIOR SHEAR WALLS, ADD LAYER OF PLYWOOD BELOW DRYWALL ON SINGLE-LAYER PARTITION TYPES, AND SUBSTITUTE LAYER OF PLYWOOD FOR DRYWALL ON STUD AT MULTI-LAYER PARTITION TYPES. PROVIDE IN LOCATIONS AS REQUIRED BY STRUCTURAL DESIGN AND AS INDICATED ON DRAWINGS. SEE STRUCTURAL DRAWINGS AND APPROVED FRAMING SHOP DRAWINGS.5. AT RC-1 CHANNELS, SCREW GWB INTO CHANNEL ONLY, DO NOT SCREW GWB TO STUD.6. PROVIDE CONTINUOUS BEAD OF ACOUSTIC SEALANT AT BOTTOM AND TOP OF ALL GWB. FILL ANY GAPS TO PROVIDE CONTINUOUS ACOUSTIC BARRIER.
ACOUSTIC MATERIALFLOORINGBASE
ACOUSTIC SEALANT ATPARTITION BASE DETAIL(HEAD SIMILAR)
PLYWD DECKING
CONT BEADACOUTIC SEALANT
FILL GAP (TYP)
2 LAYERS5/8" GWB TYPE XFIRECODE GWB
UL DES U3011-HR FIRE RATED/2-HR FIRE RATED
STC 58USG-810219
R-13 MININSULATION
412"
58"37
8"
5
AIR SPACE
5/8" GWB TYPE XFIRECODE GWB
2 X 4 WD STUD@ 16" O.C.
INTERIOR FINISHAT MASONRY WALLLOAD BEARING / NON-LOAD BEARING
MASONRYMASONRY
INTERIOR FINISHAT MASONRY WALLLOAD BEARING / NON-LOAD BEARING
1 1/2" STLHAT CHANNELS@ 24" O.C.
5/8" GWB TYPE XFIRECODE GWBPTD
6
214"
1A3A
3A R-13 THERMALINSUL
3 1 3" USGTHERMAFIBERSAFB
R-13 THERMALINSUL
1AMASONRY
INTERIOR FINISHAT MASONRY WALLLOAD BEARING / NON-LOAD BEARING
2" Z-CHANNELS@ 24" O.C.
5/8" GWB TYPE XFIRECODE GWBPTD
7
258"
CERTAINTEED"MEMBRAIN"SMART VAPORRETARDER
MIN R-13 RIGIDNSULATION
MASONRY
INTERIOR FINISHAT MASONRY WALLLOAD BEARING / NON-LOAD BEARING
7/8" STLHAT CHANNELS@ 24" O.C.
5/8" GWB TYPE XFIRECODE GWBPTD
6A
112"6"
212"31
2"
8
FOUR LAYERS 5/8"GWB TYPE XFIRECODE GWB
2 X 4 WD STUD@ 16" O.C.
2-HR UNBALANCED
MOISTURE/AIR BARRIERHENRY BLUESKIN VP 160 OR EQUAL
EXTERIOR PLYWOOD SHEATHING- SEE STRUCTURAL DRAWINGS
UL DES U344 1-HR FIRE RATEDEXPOSED TO FIRE ON INTERIOR & EXTERIOR FACES
EXTERIOR WALL BEARING/NON LOAD BEARING3"=1'-0"
2 X 6 WD STUDS @ 16" O.C.
58" EXTERIOR SHEATHINGDENSGLASS GOLD FIREGUARD TYPE XNAIL TO STUD
W2
58" 51
2"12" 5
8"
734"
EXTERIOR FINISH AS SPECIFIED:WOOD SHINGLES, FIBER CEMENT CLAPBOARD ORPANEL PTD: HARDIE PLANK OR PANEL AS INDICATED,OR APPROVED EQUAL
CERTAINTEED"MEMBRAIN"
SMART VAPORRETARDER
R=21 MINSPRAY MINERAL WOOL INSULATION ORKRAFT FACED FIBERGLASS BATT
5/8" GWBFIRECODE
MOISTURE/AIR BARRIERHENRY BLUESKIN VP 160 OR EQUAL
EXTERIOR PLYWOOD SHEATHING- SEE STRUCTURAL DRAWINGS
EXTERIOR WALL BEARING/NON LOAD BEARING3"=1'-0"
2 X 6 WD STUDS @ 16" O.C.
W1
58" 51
2"12"
718"
EXTERIOR FINISH AS SPECIFIED:WOOD SHINGLES, FIBER CEMENT CLAPBOARD ORPANEL PTD: HARDIE PLANK OR PANEL AS INDICATED,OR APPROVED EQUAL
CERTAINTEED"MEMBRAIN"
SMART VAPORRETARDER
R=21 MINSPRAY MINERAL WOOL INSULATION ORKRAFT FACED FIBERGLASS BATT
5/8" GWBFIRECODE
UL DES U348 1-HR FIRE RATEDEXPOSED TO FIRE ON INTERIOR FACE ONLYALSO USED WHERE NO FIRE RATING REQUIRED
PLAN VIEW UNLESS OTHERWISE NOTEDEXTERIOR WALL TYPES3" = 1'-0"NOTE:UNKEYED WALLS SHALL BE SAME AS KEYEDWALLS IN SIMILAR SITUATIONS.
FIBER CEMENT BOARD SIDING:SEE ELEVATIONS AND SPECIFICATIONS FOR TYPE ANDWEATHER DIMENSION. 6" WIDE 15# ROOF FELT SHALL BEPLACED BENEATH ALL BUTT JOINTS WHICH ARE THEN TO BESEALED WITH URETHANE SEALANT.
NOTE:UNKEYED WALLS SHALL BE SAME AS KEYEDWALLS IN SIMILAR SITUATIONS.
3" = 1'-0"EXTERIOR WALL TYPES
PLAN VIEW UNLESS OTHERWISE NOTEDENERGY CODE NOTE:MEET STATE OF MASSACHUSETTS ENERGY STRETCH CODE.EXTERIOR ENVELOPE THERMAL PERFORMANCE ANDSPECIFICATION SUBJECT TO REVIEW AND REVISION BYOWNER'S CONSULTING HERS RATER.
EXTERIOR WALLS 10' OR LESS FROM SIDE OR REAR LOTLINES SHALL BE FIRE RATED FROM FIRE EXPOSURE FROMEXTERIOR AND INTERIOR. DIMENSION AT RIGHT ANGLEFROM WALL.
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
WAP
WALLS &PARTITIONS
AMP
A0.2
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
04/03/19 FOR PERMITRAISE BLDG / BPDA03/19/201RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
APPROVED TILE (OR OTHERAPPROVED FINISH MATERIAL)
SCHLUTER DITRA MAT (AT TILE)
UNDISTURBED SOILS ORCOMPACTED STRUCTURAL FILLAS APPROVED BY STRUCTURAL ENGINEER
PROVIDE BELOW-SLAB DRAINAGE SYSTEMAS DETERMINED AND DESIGNEDBY OWNER'S SOILS ENGINEER
APPROVED SUBBASE MATERIAL
15 MIL VAPOR BARRIER
MIN R=15 FOR MIN 24" FROM SLAB EDGE
SLAB ON GRADE - SEE STRUCTURAL
TOP OFCONC SLAB
DIM
TYPICAL FLOOR SLAB TYPE 25
112"=1'-0" 11
2"=1'-0"4
TYPICAL FLOOR SLAB TYPE 1
DIM
TOP OFCONC SLAB
VEHICULAR TRAFFIC COATING3 COAT SYSTEM - SEE SPEC
SLAB ON GRADE - SEE STRUCTURAL
APPROVED SUBBASE MATERIAL
PROVIDE BELOW-SLAB DRAINAGE SYSTEMAS DETERMINED AND DESIGNEDBY OWNER'S SOILS ENGINEER
UNDISTURBED SOILS ORCOMPACTED STRUCTURAL FILLAS APPROVED BY STRUCTURAL ENGINEER
DIM
15 MIL VAPOR BARRIER
SCOPE CLARIFICATION FOR SPRAY-ON FIREPROOFING AT STRUCTURAL MEMBERS:
1. SEE BUILDING CODE INFORMATION ON COVER SHEET AND DWG. A0.0.2. DEFINITIONS ARE PER STATE BUILDING CODE 780CMR.3. SEE SPECIFICATION SECTION 07 81 00 - APPLIED FIREPROOFING. NOTE SUBMITTAL REQUIREMENTS. PROVIDE UL DESIGNS PROPOSED FOR USE INCLUDING THICKNESSES REQUIRED TO ACHIEVE REQUIRED FIRE RATINGS OF MEMBERS AND ASSEMBLIES.4. SEE STRUCTURAL DRAWINGS FOR STEEL FRAMING AND FLOOR DECK DESIGN.7. PRIMARY STRUCTURAL FRAME: TYPE VA: 1-HR - ALL COLUMNS - ALL BEAMS CONNECTING TO COLUMNS - ALL FLOORS CONNECTING TO COLUMNS - ALL BRACING OF STRUCTURAL FRAME8. STEEL BEAMS AT PERIMETER OF BUILDING SHALL BE CONSIDERED PART OF THE PRIMARY STRUCTURAL FRAME AND SHALL BE RATED 1-HR.9. ALL STRUCTURE SUPPORTING FIRE RATED CONSTRUCTION SHALL BE, AT A MINIMUM, OF A RATING EQUAL TO THE SUPPORTED CONSTRUCTION.
INSULATION THICKNESS NOT COUNTING TOWARD MEETINGENERGY CODE REQUIREMENT FOR ROOF INSULATION R-VALUE
MAX INSULATION THICKNESS COUNTING TOWARD MEETINGENERGY CODE REQUIREMENT FOR ROOF R-VALUE
1/4" PER FOOT TAPER (NTS)1"MIN. PROPOSEDINSULATION THICKNESS
DIAGRAM: MAXIMUM TAPERED INSULATION THICKNESS COUNTING TOWARD ENERGY CODE COMPLIANCE
1-HOUR FIRE RATED UL DES L521
TYPICAL ROOF CONSTRUCTION11
2"=1'-0"1
60MIL SINGLE MEMBRANE EPDM ROOFFULLY ADHERED SYSTEM WARRANTED
FOR USE IN UNVENTED ROOF ASSEMBLIESCARLISLE SYNTEC OR EQUAL
ALL DETAILS PER MANUFACTURER'SINSTRUCTIONS, PROVIDE 20-YR
MANUFACTURER'S WARRANTY
JOIS
T D
EPTH
134"
SEE
STRU
CTUR
AL
3/4" T&G PLYWOOD DECK.T&G EDGES GLUED TOGETHER;PANELS GLUED AND NAILED TO JOISTS
EXPANDING SPRAY FOAM INSULATIONPERM RATING LESS THAN 2 PERM-INCH
TOP OFROOF DECKING
34"
USG RC-1 CHANNEL PERPENDICULAR TO JOISTS,SPACING AS RECOMMENDED BY USG FOR CONDITION.FASTEN GWB TO CHANNEL ONLY, DO NOT FASTENGWB TO JOIST.
VENEER PLASTER ON 2 LAYERS 5/8" FIRECODE GWB.LATEX PAINT CLASS III VAPOR RETARDER
INSULATION OPTION 1:1. INSULATION BETWEEN ROOF JOISTS/RAFTERS: TOTAL INSULATION VALUE R-38 MIN.2. EXPANDING SPRAY FOAM MATERIAL PROVIDING AT LEAST 40% OF REQUIRED R-VALUE OF REQUIRED INSULATION IS IN DIRECT CONTACT WITH UNDERSIDE OF ROOF DECK AND ADJACENT FRAMING MEMBERS, THEN VENTING OF RAFTER SPACES NOT REQUIRED.3. IF INSULATION PERMABILTY<2 PERM-INCH, NO VAPOR BARRIER REQUIRED.4. PROVIDE CONTINUOUS TAPERED POLYISO INSULATION MIN SLOPE 1/4" PER FOOT FOR STORM DRAINAGE.
ALL LOUVERS & DIFFUSERS SHALL MEET THEREQUIREMENTS OF 780CMR 716.6.2 FORMEMBRANE PENETRATIONS
1/2" DENSDECK COVERBOARD
RIGID POLYISO TAPERED INSULATIONSLOPED 1/4" PER FOOT TO DRAINMIN R-VALUE PER INCH = 6.5.PROVIDE THICKNESS AS REQUIRED TOMEET ENERGY CODE REQUIREMENTS
1/2" DENSDECK ROOF BOARD
TJI or OPEN WEB - SEE STRUCTURAL.
SCHLUTER DITRA MAT AT TILE
34"
1-HOUR FIRE RATEDUL DES L583STC: 54 MINIIC: 72 MIN W/ CARPET 51 MIN W/ PARQUET WOOD FLOOR
TOP OFSUBFLOOR
34" HARDWOOD FLOORINGOR OTHER FINISH FLOOR AS SPECIFIED
1" MAXXON SYSTEM GYP-CRETESELF-LEVELING TOPPING SLAB
THERMAFIBER SAFB SOUNDATTENTUATION FIRE BATT 9" TOTAL
3/4" T&G PLYWOOD DECK.T&G EDGES GLUED TOGETHER;PANELS GLUED AND NAILED TO JOISTS
VENEER PLASTER ON2 LAYERS 5/8" FIRECODE GWB.
ISOMAX SOUND ISOLATION CLIPOR APPROVED EQUALSPACING AS RECOMMENDED BYMANUFACTURER
SEE
STRU
CTUR
AL
138"
234"
JOIS
T D
EPTH
ADJUST DIMENSIONS ASREQUIRED BY FINAL FINISHFLOOR MATERIALSELECTION
211
2"=1'-0"
TYPICAL FLOOR CONSTRUCTION TYPE 1
ALL LOUVERS & DIFFUSERS SHALL MEET THEREQUIREMENTS OF 780CMR 716.6.2 FORMEMBRANE PENETRATIONS
.40" SOUND ATTENUATING MAT ANDFLOOR PRIMER. MAXXON ENKASONIC HPSYSTEM OR APPROVED EQUAL.
7/8" STL FURRING CHANNEL
TJI or OPEN WEB - SEE STRUCTURAL.
34"
2-HOUR FIRE RATEDUL DES L538
STC: 51 MINIIC: 72 MIN W/ CARPET 51 MIN W/ PARQUET WOOD FLOOR
THREE LAYERS 3" THERMAFIBERSAFB SOUND ATTENTUATIONFIRE BATT - 9" TOTAL
3/4" T&G PLYWOOD DECK.T&G EDGES GLUED TOGETHER;PANELS GLUED AND NAILED TO JOISTS
VENEER PLASTER ON 2 LAYERS 5/8"FIRECODE GWB. FASTEN GWB TOCHANNEL ONLY, DO NOT FASTEN GWBTO JOIST.
USG RC-1 CHANNEL PERPENDICULARTO JOISTS, 16" OC.
FLOOR JOIST @ 16" O.C. -TRUSJOIST SYSTEM OR APPROVED EQUAL(MIN 9 1/2" "I" JOIST)SEE FRAMING DRAWINGS
SEE
STRU
CTUR
AL23
8"JO
IST
DEP
TH
311
2"=1'-0"
TYPICAL FLOOR CONSTRUCTION TYPE 2
1 LAYERS 5/8" FIRECODE GWB.
138"
ADJUST DIMENSIONS ASREQUIRED BY FINAL FINISHFLOOR MATERIALSELECTION
TOP OFSUBFLOOR
SCHLUTER DITRA MAT AT TILE
34" HARDWOOD FLOORINGOR OTHER FINISH FLOOR AS SPECIFIED
1" MAXXON SYSTEM GYP-CRETESELF-LEVELING TOPPING SLAB.40" SOUND ATTENUATING MAT ANDFLOOR PRIMER. MAXXON ENKASONIC HPSYSTEM OR APPROVED EQUAL.
34"
2-HOUR FIRE RATEDUL DES L538
STC: 51 MINIIC: 72 MIN W/ CARPET 51 MIN W/ PARQUET WOOD FLOOR
THREE LAYERS 3" THERMAFIBERSAFB SOUND ATTENTUATIONFIRE BATT - 9" TOTAL
3/4" T&G PLYWOOD DECK.T&G EDGES GLUED TOGETHER;PANELS GLUED AND NAILED TO JOISTS
VENEER PLASTER ON 2 LAYERS 5/8"FIRECODE GWB. FASTEN GWB TOCHANNEL ONLY, DO NOT FASTEN GWBTO JOIST.
USG RC-1 CHANNEL PERPENDICULARTO JOISTS, 16" OC.
FLOOR JOIST 2x10 @ 16" O.C.SEE FRAMING DRAWINGSSE
E ST
RUCT
URAL
238"
JOIS
T D
EPTH
3A11
2"=1'-0"
TYPICAL FLOOR CONSTRUCTION TYPE 3A
1 LAYERS 5/8" FIRECODE GWB.
138"
ADJUST DIMENSIONS ASREQUIRED BY FINAL FINISHFLOOR MATERIALSELECTION
TOP OFSUBFLOOR
SCHLUTER DITRA MAT AT TILE
34" HARDWOOD FLOORINGOR OTHER FINISH FLOOR AS SPECIFIED
1" MAXXON SYSTEM GYP-CRETESELF-LEVELING TOPPING SLAB.40" SOUND ATTENUATING MAT ANDFLOOR PRIMER. MAXXON ENKASONIC HPSYSTEM OR APPROVED EQUAL.
34"
1-HOUR FIRE RATEDUL DES L514
THREE LAYERS 3" THERMAFIBERSAFB SOUND ATTENTUATIONFIRE BATT - 9" TOTAL
3/4" T&G PLYWOOD DECK.T&G EDGES GLUED TOGETHER;PANELS GLUED AND NAILED TO JOISTS
VENEER PLASTER ON 1 LAYERS 5/8"FIRECODE GWB. FASTEN GWB TOCHANNEL ONLY, DO NOT FASTEN GWBTO JOIST.
USG RC-1 CHANNEL PERPENDICULARTO JOISTS, 16" OC.
FLOOR JOIST 2x10 @ 16" O.C.SEE FRAMING DRAWINGSSE
E ST
RUCT
URAL
118"
JOIS
T D
EPTH
611
2"=1'-0"
FLOOR CONSTRUCTION TYPE 6
118"
ADJUST DIMENSIONS ASREQUIRED BY FINAL FINISHFLOOR MATERIALSELECTION
TOP OFSUBFLOOR
34" HARDWOOD FLOORINGOR OTHER FINISH FLOOR AS SPECIFIED
.40" SOUND ATTENUATING MAT ANDFLOOR PRIMER. MAXXON ENKASONIC HPSYSTEM OR APPROVED EQUAL.
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
WAP AMP
A0.3
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
FLOOR & CEILINGASSEMBLIES
NEW MULTI-FAMILY DWELLING
16-297
874 East Sixth St.South Boston 02127
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
04/03/19 FOR PERMITRAISE BLDG / BPDA03/19/201RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
WINDOW TYPESALL INSULATED GLASS1" TEMPERED UNITS / LOW E / ARGON GAS FILLED SPACE
8'-0"
8'-2
"
3'-0
"
2'-4" 2'-4"
AB
8'-2
"
C
DE
CLAD WOOD WINDOWSBY MARVIN OR EQUAL
FIXEDGL
FIXEDGL
FIXEDGL
FIXEDGL
3'-0"
3'-0
"
3'-4"9'-0"
3'-0
"
2'-4" 2'-4"
FIXEDGL
FIXEDGL
4'-4"
FIXEDGL
FIXEDGL
FIXEDGL
FIXEDGL
OUTSWINGCASEMENT
4'-0"
OUTSWINGCASEMENT
SILL MIN 3' ABOVE FIN. FLR@ OPERABLE WINDOW
FIN. FLOOR
8'-2
"
FIXEDGL 3'
-0"
3'-0"
OUTSWINGCASEMENT
8'-2
"
8'-0"
5'-1
0"
2'-4" 2'-4"
FIXEDGL
3'-4"
FIXEDGL
FIXEDGL5'
-10"
2'-4"
FIXEDGL5'
-10"
4'-0"
FIXEDGL
8'-2
"
FIXEDGL 3'
-0"
4'-0"
FIXEDGL
CEILING
6'-8"
8'-2
"
FIXEDGL
FIXEDGL
FIXEDGL
3'-0"
3'-0
"
7'-10"
8'-2
"
FIXEDGL
FIXEDGL
FIXEDGL
3'-0"
3'-0
"
FGH
5'-1
0"
3'-0"
FIXEDGL
JKLM
SIM OPP HAND
8'-2
"
3'-0
"
3'-0"
OUTSWINGCASEMENT
N
5'-4
1 2"
SILL MIN 3' ABOVE FIN. FLR@ OPERABLE WINDOW
FIN. FLOOR
CEILING
SILL MIN 3'ABOVE FIN. FLR@ OPERABLEWINDOW
FIN. FLOOR
CEILING
2 22
2222
22222
WINDOW NOTES
1. FENESTRATION U-FACTOR SHALL MEET OR EXCEED ZONE 5 CODEREQUIREMENT OF .30.
2. WINDOWS SHALL BE BY MARVIN WINDOWS OR APPROVED EQUAL.
3. WINDOWS 2nd FLOOR AND ABOVE ARE BASED ON MARVIN"INTEGRITY" WOOD-ULTREX SERIES.
4. DELETED
5. FIXED GLASS UNITS:5.1. PERFORMANCE:
1" INSULATED UNITS, 14" TEMPERED GLASS, 12" SPACE 90%ARGON FILLED. PPG SOLARBAN 70 XL STARPHIRE LOW E #2.U=.21; SC=.31; SHGC=.27
5.2. PRIOR TO FABRICATION, FIELD VERIFY ALL DIMENSIONS ANDACTUAL OPENINGS, AS CONSTRUCTED.
2.3. FABRICATION AND ERECTIONS SHALL BE IN ACCORDANCEWITH REVIEWED SHOP DRAWINGS.
6. PROVIDE SCREENS AT ALL OPERABLE WINDOWS.
7. PROVIDE ON-SITE MOCK UP OF ALL WINDOW AND DOOR TRIMDETAILS FOR OWNER'S APPROVAL PRIOR TO PROCEEDING WITHORDERING AND FABRICATION.
8. PROVIDE WINDOW AND DOOR DETAILING AS REQUIRED BYBUILDING CODE, MANUFACTURERS OF PRODUCTS USED, BUILDINGCONDITIONS AND AS INDICATED. ADJUST DETAILS AS REQUIREDFOR EXTERIOR STRAPPING, EXTERIOR FINISH MATERIAL, EXTERIORINSULATION AND ANY OTHER CONSTRUCTION ITEM WHICH MAYMODIFY THE OVERALL WALL THICKNESS, WHETHER INDICATED ORNOT. PROVIDE HEAD, JAMB AND SILL EXTENSIONS WHEREREQUIRED, WHETHER INDICATED OR NOT.
9. SEE BUILDING ELEVATIONS FOR WINDOW UNIT LOCATIONS.
10. DESIGN INTENT:A. GLAZED FRAME UNITS FLOOR TO CEILING.B. OPERABLE WINDOWS WHICH CONFORM WITH DIMENSIONAL
REQUIREMENTS FOR EMERGENCY RESCUE AND ESCAPE WINDOWSAT BEDROOMS AND WHERE INDICATED.
C. AT OPERABLE UNITS, PROVIDE SILL AT MINIMUM 3'-0" ABOVEFINISH FLOOR, SO THAT OPENING NEED NOT BE RESTRICTED.
11. UNIT DIMENSIONS SHALL BE ADJUSTED AS REQUIRED BY FIELDCONDITIONS AND ACTUAL OPENING DIMENSIONS. CONTRACTORSHALL FIELD VERIFY ROUGH OPENINGS IN FIELD AS REQUIRED.
VAPOR RETARDERON WARM SIDEOF INSULATION
INSULATION ASSPECIFIED
EXTERIOR SIDING
EXTERIOR SHEATHING
VAPOR PERMEABLEEXTERIOR AIR BARRIER
EXTEND VAPORRETARDER ON ALLSURFACES OF THEOPG, FOR FULLOPG DEPTH.
W.R.GRACEVYCOR PLUS
SELF-ADHERED FLASHING
TYP AT ALL OPGSINSTALL PER
MANUFACTURER'SINSTRUCTIONS
DOOR, WINDOW OROTHER ITEM
AS INDICATED
APPLIES TO ALL OPENINGS IN EXTERIOR WALL
INSULATE ALLGAPS (TYP)
C1
C2A
178"
FIBER CEMENTPANEL SYSTEM
CONTINUOUS VAPORPERMEABLE AIR /WEATHER BARRIER
VAPORRETARDER
APPROVEDWINDOW SYSTEM
2"
2"
ALUM PNLHOR BAND
CONTINUOUS VAPORPERMEABLE AIR /WEATHER BARRIER
PTD WDSILL & TRIM
2A0.3
WINDOW HEADERFLUSH W FRAMING- SEE STRUCTURAL
INSULATE ALL GAPS
ALUM PNL
C2
APPROVEDWINDOW SYSTEM
C2A
PTD WD SILL& TRIM
FLASHING
PLYWD SHEATHING
CONTINUOUS VAPORPERMEABLE AIR /WEATHER BARRIER
2"
VAPORRETARDER
ALL INSULATED GLASS1" TEMPERED UNITS / LOW E / ARGON GAS FILLED SPACE DOOR TYPES
E01MAIN ENTRYDOOR ASSEMBLY
O.H. SECTIONAL GARAGE DOOR
7'-0
"
2"
2"2"
E05
7'-0
"
FIXED 1" INSUL GL (TYP)
SGD6' X 7'
7'-0
"
1" INSUL GL
3'-0"
2" FRAMETYPICAL
8'-10"
6'-0"
1" INSULGL
E06
7'-0
"
8'-2
"
FIXED 1" INSUL GL
SGD6' X 7'
6'-10"
E02
18'-0"
1'-0"MIN CLEARANCEON PULL SIDE
4'-2"
8"
4" 4"
4"
SAFETYGL
SEE BUILDING ELEVATIONSFOR DOOR LOCATIONS
6'-0"
EO7 SIM OPP HAND
7'-0
"
8'-2
"
E04
100 MAX SQ. IN.FIRE RATEDSAFETY GLASS
3'-1
0"2'
-1"
4"6"
3'-0"
2" HMFRAME
GLAZING (TYP)
E03
E10
2" HMFRAME
6"
2'-0
"3'
-11"
1'-0"
MAN DOOR @ GARAGE
E11 E08
7'-0
"
8'-2
"
FIXED 1" INSUL GL
SGD6' X 7'
8'-0"6'-0"
3'-4"
7'-2
"
3'-4"
7'-2
"
2" HMFRAME
E09
3'-4"
7'-0
"
1st FLR
INT LANDING
FIXEDGL
9'-3
1 2"
3'-0
"
2'-0"
FIXEDGL
SOLID PNL FORINTERCOM.SET AT HEIGHTAS REQ'D FORAPPROVEDINTERCOM
1" INSUL GL
8'-1
"
22
22
2
DOOR NOTES
1. DWELLING UNIT MAIN ENTRY DOORS SHALL BE FIRE RATEDSOLID WOOD PANEL DOOR. ASSEMBLY SHALL BE FIELDPAINTED, COLOR SELECTED BY ARCHITECT.
2. NEW INTERIOR WOOD DOORS SHALL BE 1 3/4" THICK SOLIDCORE DOORS.
3. PROVIDE RATED DOOR ASSEMBLIES IN PARTITIONS REQUIREDTO BE RATED INCLUDING BUT NOT LIMITED TO TENANTSEPARATION, CORRIDORS AND STAIRWAYS.
4. CONTRACTOR SHALL EMPLOY THE SERVICES OF A QUALIFIEDHARDWARE CONSULTANT AND PREPARE A COMPLETEHARDWARE SCHEDULE. SUBMIT SCHEDULE TO ARCHITECT.SUBMIT SAMPLES OF EACH ITEM OF HARDWARE PROPOSED FORUSE.
5. DOOR FENESTRATION U-FACTOR SHALL MEET OR EXCEEDZONE 5 CODE REQUIREMENT OF .30.
6. PROVIDE ON-SITE MOCK UP OF ALL TRIM DETAILS FOROWNER'S APPROVAL PRIOR TO PROCEEDING WITH ORDERINGAND FABRICATION.
7. PROVIDE COMPLETE WEATHER STRIPPING PACKAGE AT ALLEXTERIOR DOORS.
8. PROVIDE ACOUSTIC SEALS AT ALL UNIT ENTRY DOORS.
9. PROVIDE CLOSER AT BUILDING ENTRANCE DOORS AND ASREQUIRED AT FIRE-RATED DOORS.
10. PROVIDE HARDWARE AS REQUIRED BY DOOR CODE-REQUIREDFIRE-RATING.
11. PROVIDE WINDOW AND DOOR DETAILING AS REQUIRED BYBUILDING CODE, MANUFACTURERS OF PRODUCTS USED,BUILDING CONDITIONS AND AS INDICATED. ADJUST DETAILSAS REQUIRED FOR EXTERIOR STRAPPING, EXTERIOR FINISHMATERIAL, EXTERIOR INSULATION AND ANY OTHERCONSTRUCTION ITEM WHICH MAY MODIFY THE OVERALL WALLTHICKNESS, WHETHER INDICATED OR NOT. PROVIDE HEAD,JAMB AND SILL EXTENSIONS WHERE REQUIRED, WHETHERINDICATED OR NOT.
LOCATION / COMMENTS
EXTERIOR DOOR ASSEMBLY SCHEDULEASSEMBLY
NO.
E01
DOOR OPGDIMS (1)
HGTWIDTH
7'-0"
E02
FIRERATING
E03
18'-0" 7'-0"
ALUM/GLASS
DOORS 134" THICK UNLESS OTHERWISE NOTED
THRESHOLD
7'-0"
MAIN ENTRY
GARAGE DOOR W/ AUTOMATIC OPERATOR
CLOSER
WD/GLASSHM/GLASS
E04 STAIR No .1 AT BASEMENT.PROVIDE INSULATED DOOR
ALUM
ALUM
ALUM
E05 CLAD WOOD/GLASS
E08
"MAN DOOR" AT GARAGE.PROVIDE INSULATED ASSEMBLY
SLIDING GLASS DOORS AT FRONT UNIT BALCONIES
YES3'-0"
3'-0"
YES
6'-0"
(1) DOOR DIMENSION, SEE DOOR ASSEMBLY TYPES FOR OVERALL ASSEMBLY NOMINAL DIMENSION
MATERIAL
DOOR FRAME
ALUM
WOOD
HM
7'-0"3'-0" HM/GLASS HM 90 MIN
B-LABEL
7'-0"
E06 6'-0" 7'-0"
E07 6'-0" 7'-0"
6'-0" 7'-0"
ALUM
YES
YES
E09
ALUM
ALUM
SLIDING GLASS DOORS AT REAR UNIT BALCONIES
E10 7'-0"3'-0"
7'-0"3'-0"
HMHM
HMHM
ALUM
ALUM
ALUM
YES
YES
ROOF ACCESS DOORPROVIDE INSULATED ASSEMBLYELEV MACHINE ROOM, PROVIDE INSULATEDASSEMBLY
90 MINB-LABEL
E11
STAIR No .2 AT 1st FLOORPROVIDE INSULATED DOOR7'-0"3'-0"
ALUM/GLASS ALUM ALUM
A0.4DOORS &WINDOWS
3"=1'-0"3"=1'-0"AIR BARRIER AND VAPOR RETARDER TYP.AT OPENINGS: JAMB, HEAD, SILL1
3"=1'-0"
3
4 23"=1'-0"
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
AMP
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
NEW MULTI-FAMILY DWELLING
HEAD - TYPICAL
SILL - TYPICALJAMB - TYPICAL
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
16-297
874 East Sixth St.South Boston 02127
AMP/WAP
04/03/19 FOR PERMITRAISE BLDG / BPDA03/19/201RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
GROUND FLOOR PLAN
L1
L3
L2
L4
L C
AR
C
gov
COMPACT SPACE 7'-0" x 18'-0"
WTR/SPRKR
N
(1) PROVIDE COPPER PANS AT TUBS AND SHOWERS.(2) PROVIDE COPPER DRAINED OVERFLOW PAN BELOW WASHING MACHINES.(3) UNLESS OTHERWISE NOTED, WALLS AND CEILINGS VENEER PLASTER ON FIRE-RATED BLUEBOARD
WALLS
PTD
SPACE FINISH SCHEDULE GROUND FLOORSPACE NAMENO. BASEFLOOR
TYPECEILING(3)
E WS
PTDPTD
(3)
8'-6"
HGTREMARKS
GWB PTDGARAGE VT
STAIR NO. 1
PORC. TILE PORC. TILE
PTD
MECH. ROOM
MECH / SPRK RM.
A C
ELEVATOR
CONC
ELEVATOR
VT
VT
NWALLS
PTD
SPACE FINISH SCHEDULE FIRST FLOORSPACE NAMENO. BASEFLOOR
TYPECEILING(3)
E WS
PTDPTDPTD
(3)
HGTREMARKS
GWB PTDENTRY
LIVING ROOM
CLOSETS
CER.TILE
PTD
WOOD
WOOD
WOOD
PORC. TILE PORC. TILE
UNIT 1&UNIT 2
WOOD
DINING ROOM WOOD WOOD
BEDROOMS
PORC. TILE PORC. TILE
WOOD WOOD
BATHROOMS CER.TILE
CER.TILE
CER.TILE
KITCHEN WOOD WOOD
(1) PROVIDE COPPER PANS AT TUBS AND SHOWERS.(2) PROVIDE COPPER DRAINED OVERFLOW PAN BELOW WASHING MACHINES.(3) UNLESS OTHERWISE NOTED, WALLS AND CEILINGS VENEER PLASTER ON FIRE-RATED BLUEBOARD
PORC. TILE PORC. TILEELEVATOR.
PTD PTDPTD PTD
MECH / WD WOOD WOOD
STAIR WAY 1 GWBPTD
PLAM. PLAM. PLAM. PLAM. PLAM.
CORRIDOR
SPACE FOR VEHICLEMANUEVERABILITY
STANDARD SPACE 8'-6" x 20'-0"
B
PRE-CAST CONCRETELAGGING RETAINING WALLSEE GEOTECHNICALCONSULT. DWGS. ES-1 & ES-2
STEE
L BE
AM A
BOVE
A B C
11'-0"20'-3"
20'-
2"10
'-0"
24'-
2"10
'-8"
19'-
0"19
'-6"
15'-
0"
1
2
3
4
6
5
4'-238"
UP
STEE
L BE
AM A
BOVE
COMPACT SPACE 7'-0" x 18'-0"
COMPACT SPACE 7'-0" x 18'-0"
COMPACT SPACE 7'-0" x 18'-0"
COMPACT SPACE 7'-0" x 18'-0"
35'-9"
7'-0
"
5'-038"
BA3.2
CA3.2
1/8" = 1'-0"1/8" = 1'-0"
CANTILEVERWING ABOVE
PROPERTY LINE (TYP)
PRO
PERT
Y LI
NE
(TYP
)
STANDARD SPACE 8'-6" x 20'-0"
STANDARD SPACE 8'-6" x 20'-0"
A3.2B
CA3.2
AA3.1
AA3.1
DA3.3
DA3.3
S1.11
S1.11
125'
-0"
BRACED WALL PARTITION (BWP):
ATTACH SHEATHING BOTH SIDES W/SCREWS 4" O.C. AT PERIMETER OFEACH SHEET, AND 8" O.C. IN FIELD
CONC
CONC
8'-5"
LEGEND
W1
GRAPHIC SCALE IN FEET0 4 8 16
PLAN NORTH
EXISTING SITE INFORMATION TAKEN FROM"SITE PLAN" BY BOSTON SURVEY, INC.
3'-6
"3'-
0"
RETAININGWALL
9'-9
"18
'-0"
CANTILEVERWING ABOVE
DRIVEWAY
GARAGE
11'-4
3 4"
19'-
814"
UP
STEPS UP TOBACK YARD
MIN
TUR
NING
RAD
IUS
LANDSCAPE
COMPACT SPACE 7'-0" x 18'-0"
3'-4
"
LANDSCAPED REAR YARD
SEE CIVIL DWGS FOR STORMWATER RETENTION SYSTEM
5'-6
"
4.1
NEW 3' DOOROPG
NEW 18' OHDOOR OPG. CUTFOUNDATIONAS REQUIRED
EA3.4
EA3.4
VEST.
4'-658"
EXIST. CURB CUTAA3.1
DA3.3
EXISTEL.16'-6"
15'-0"3'-3"
6'-0
"13
'-0"
STAIRWAY 1
PAVED
UP
18'-6" (MIN)
RL
ELEC
RL3'-4
"
5'-0
"
3'-0
"7'
-6"
5'-0
"5'
-0"
4'-0
"9'
-5"
9'-5
"
SLO
PIN
G F
LOO
R
DN
9'-5
"3'
-1"
E01
E02
E03
E04
FIRST FLOOR PLAN1/8" = 1'-0"
FIRST FLOOR PLAN
UNIT No.11,542±SF
L1
L3
L2
L4
L C
AR
C
gov
UPDN
11'-0"
11'-0"3'-3"
BALCONY
LIVING
CORR.
1
AA3.1
B CA
2
3
4
6
5
A3.2B
CA3.2
DRO
PPED
BEA
M A
BOVE
7'-878"
BALC
DRO
PPED
BEA
M A
BOVE
RL
6'-9
"
LIVING
FRAMING RADIUS 20'-3"
UNIT No.21,415±SF
HALLWAY 1
5'-0
"
CANTILEVERWING ABOVE
DRO
PPED
BEA
M A
BOVE
PRO
PERT
Y LI
NE
(TYP
)
BA3.2
CA3.2
AA3.1
DA3.3
DA3.3
W2
W2
W2
W24
W1
1A6.1
1A6.1
UP
FRAMING RADIUS 20'-3"
DRO
PPED
BEA
M A
BOVE
514"
MASTERBATH
VAN20x36
9'-312"
8'-3"
VAN20x36
3'-2
"
CL
DN
MASTERBEDROOM
KITCH
BATH
BEDROOM 2
MECH -W/D
CL
CLOS
2'-1
"
MASTERBATH
VAN20x48
BATH
SHOWER36x48
VAN20x48
MECH
W1
BEDROOMMIELEWASHERDRYERSTACK
W/D
SHEL
VES
/ BU
ILT-
INS LIN
WET BAR
HALLWAY 1
MIELEWASHERDRYERSTACK
COATS
PAN.
MASTERBEDROOM
EXTERIOR STAIRTO GRADE
BEDROOM 1
9'-034"
10'-
1"
CL
STAIRWAY 1
STAIR WAY 2
5'-0
"
CL
4.1
20'-
2"10
'-0"
24'-
2"10
'-8"
19'-
0"19
'-6"
15'-
0"5'
-6"
8'-0"
EA3.4
EA3.4
5'-2
1 2"5'
-01 2"
11'-512"
15'-
8"2'
-6"
6'-6
"
KITCH.
PANTRY
5'-0
"5'
-0"
3'-0
"
4'-7
"
7'-6
"
3'-4
"
3070
9'-0"
7'-0" 7'-0" 4'-9"
2'-6
"7'
-10"
5'-0
"
4'-5
5 8"
8'-6
"
4'-0
"
15'-234"
E05
E06
E07
E08
E09
A CB
8'-9" 8'-3"
10'-1012" 8'-0"
OPG C.L. DIMS
WALL LAYOUT DIMS7'-7"
3'-8"
10'-0"
RL
EL.18'-0"
EL.17'-6"
EL.17'-6"
SLOPING WALKWAY SLOPE NTE 1:20 16'-9"
16'-5.5"17'-0"
1A3.4
1A1.3
2A1.3
5.9
6"
1.1
6"
B.9
6"
B.9
6"
B.9
B.9
5.9
1.1
6"6"
SLOPE ROOF TO DRAIN
CL
CL
1470
W2
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
W24
4
4
1A3.4
4
COAT CL
5A7.1
7A7.1
2A5.1
1A5.1
1A7.1
CORR
VESTIBULE
CORRIDOR
VINYL(1) JOHNSONITE "CUBIS"LANDINGS, TREADS, RISERS
VINYLSTAIR (1)
7'-6"
4'-0"
7'-8" to 8'-8"
8'-8"
8'-8"
PTD PTDPTD PTD
GWBPTD
GWBPTD
GWBPTD
P-LAM P-LAM P-LAM P-LAM P-LAM
VINYL(1) JOHNSONITE "CUBIS"LANDINGS, TREADS, RISERS
VINYLSTAIR (1)
STAIR WAY 2
WOOD WOOD
7'-5"
8'-5"
7'-5"
8'-10"
8'-10"
8'-5"
5'-8
"
3070
3070
3070
3070
3070
3070
POCKET3070
3070 3070
PR1670PR1670
POCKET3070
POCKET3070
POCKET3070
3070
4
4
WD COL1-HR RATED
2666
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
AMP
GROUND FLOOR &1st FLOOR PLAN
AMP
A1.1
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
08.28.17 ADD 1 FULL SIZE CAR SPACE
05.18.18 REVISE ELEV'S FOR BPDA
04.03.19 FOR PERMIT
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
RAISE BLDG / BPDA03/19/201RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
ROOF PLAN
SLO
PE R
OO
F IN
SULA
TIO
M 1
/4"
per
FO
OT
6" dia DOWNSPOUT6" dia DOWNSPOUT
24" x 36"SYNTHETICWALKING PADS
ROOFTOPCONDENSERS
NO PARAPET ATCANTILEVERED WINGS
2
3
4
6
5
1
B CA
ELEVATORMACHINEROOM OVERELEVATORHOISTWAY
ELEVATOR MACHINE ROOM:FIRE RATED 2 HRS.MIN INTERIOR DIMS:5'-9" x 5'-9" X 7'-6" HGTDOOR: 3'x7'-0"
DN
PARAPET
PARAPET
1/8" = 1'-0"
PROPERTY LINE (TYP)
PRO
PERT
Y LI
NE
(TYP
)
STEPS ASREQUIREDAT DOOR
VENT ELEVATOR HOISTWAY ANDMACHINE ROOM PER CODE
STAIR AND ELEVATOR:MIN R-21 AT WALLS, R-49 AT ROOFS
A3.2B
CA3.2
BA3.2
CA3.2
AA3.1
AA3.1
DA3.3
DA3.3
8'-1
1"
7'-9"
1A6.1
1A6.1
1A6.1
3
3
A6.1
3A6.1
3A6.1
A6.1
3A6.1
1A0.3
BRISE SOLIELEQUALLYSPACED
SPACE FINISH SCHEDULE SECOND & THIRD FLOORS
UNIT No.31,200±SF
UNIT No.41,750±SF
BEDROOM
BEDROOM11'6 x 11'4155±SF
DRO
PPED
BEA
M A
BOVE
SECOND FLOOR PLAN
CORR.
L1
L3
L2
L4
L C
AR
C
gov
STAIRWAY 1
7'-1112"
MASTERBEDROOM250 ±SF
B CA
BALCONY
2
3
4
6
5
1
11'-512"
8'-0"
16'-
103
4"
7'-6
1 2"
7'-4"
2'-2
"
FRAME RADIUS 23'-2"
11'-0"
7'-878"
FRAMING RADIUS 60'-0"
514"
LIVING
HALLWAY 1
FRAMING RADIUS 20'-3"
BALC
15'-258"3'-3" 9'-07
8" 11'-0"
1/8" = 1'-0"
UPDN
DRO
PPED
BEA
M A
BOVE
DRO
PPED
BEA
M A
BOVE
DRO
PPED
BEA
M A
BOVE
PROPERTY LINE (TYP)
PRO
PERT
Y LI
NE
(TYP
)
BA3.2
CA3.2
A3.2B
CA3.2
AA3.1
AA3.1
DA3.3
DA3.3
BRACED WALL PARTITION (BWP):
ATTACH SHEATHING BOTH SIDES W/SCREWS 4" O.C. AT PERIMETER OFEACH SHEET, AND 8" O.C. IN FIELD
W1
S1.11
W2
W1
W2
4
W1
GRAPHIC SCALE IN FEET0 4 8 16
PLAN NORTH
EXISTING SITE INFORMATION TAKEN FROM"SITE PLAN" BY BOSTON SURVEY, INC.
1A6.1
LIVING
CL
MASTERBATH
CL
MECHBATH
STACKEDMIELEW/D
SHOWERBASE36x66
KITCHEN
HALLWAY
CL
4
23'-11"
DN
UP
14'-
6"
MASTERBEDROOM
VAN20x36
9'-312"
8'-3"
VAN20x36
3'-2
"
MASTERBEDROOM 2
26'-
10"
COATS
10'-
6"
MASTERBATH 2
BATH
MASTERBEDROOM 1
UNIT No.51,626±SF
UNIT No.61,305±SF
LIVING
DRO
PPED
BEA
M A
BOVE
THIRD FLOOR PLAN
7A7.2
CORR.
L1
L3
L2
L4
L C
AR
C
gov
7'-1112" MASTER
BEDROOM
B CA
BALCONY
2
3
4
6
5
1
11'-512"
8'-0" 7'-6
1 2"
7'-4"
FRAME RADIUS 23'-2"
7'-878"
FRAMING RADIUS 60'-0"
LIVING
ENTRY
FRAMING RADIUS 20'-3"
BALC
15'-258"3'-3" 9'-07
8" 11'-0"
1/8" = 1'-0"
CL
2'-1
"COATS
UPDN
DRO
PPED
BEA
M A
BOVE
DRO
PPED
BEA
M A
BOVE
DRO
PPED
BEA
M A
BOVE
PROPERTY LINE (TYP)
PRO
PERT
Y LI
NE
(TYP
)
BA3.2
CA3.2
A3.2B
CA3.2
AA3.1
AA3.1
DA3.3
DA3.3
W1
W2
W2
W1
4
W1
1A6.1
1A6.1
20'-
0"
DN
CL/STOR
514"
MASTERBATH
VAN20x36
9'-0"
8'-3"
VAN20x36
3'-2
"
CL
BATH
MASTERBEDROOM
6'-1
0"
MIELEWASHERDRYERSTACK
BEDROOM
PANTRY /MECH /W-D
KITCH
MASTERBATH
VAN20x48
BATH
4
BEDROOM
KITCH
5'-0
"
SHOWER36x48
VAN20x48
11'-8"
4'-8"
SHEL
VES
/ BU
ILT-
INS
5'-0
"
8'-6
"3'
-0"
WET BAR
CL
CL L.
CL
SHOWER 36x60
LMASTERBATH 1
PANTRY/MECH /W-D
WET BAR
STAIRWAY 1STAIR
WAY 1
STAIRWAY 2
STAIRWAY 2
PR 1870
1870
CLMIELEWASHERDRYERSTACK
W/D
LIN
COAT CL
MECH
20'-
2"10
'-0"
24'-
2"10
'-8"
19'-
0"19
'-6"
15'-
0"
10'-
0"24
'-2"
20'-
2"10
'-8"
19'-
0"25
'-0"
15'-
0"
2'-2
" 11'-0"
4.1
1A6.1
5'-6
"
5'-6
"
3'-8
"
4.1
5'-6
"
1A6.1
5'-2"
3070
3070 PR2070 PR2070
3070 3070
9'-0"
EA3.4
EA3.4
EA3.4
EA3.4
EA3.4
EA3.4
33' =
1/3
DIA
GO
NAL
DIM
ENSI
ON
OF
AREA
SER
VED
4'-4
"
KITCH
3070
ALIGN WINDOWSWITH FLOOR BELOW
ALIGN WINDOWS WITH FLOOR BELOW
4'-0
"
PANTRY
E05
E06
E07
E08
E05
E06
E07
E08
E10
E11
A CBA CBA CB
3'-9"
11'-512" 7'-7"
3'-8"WALL LAYOUT DIMS
9'-312"18'-101
2" 7'-5"
3'-8"
B.9
B.9
B.9
B.9
B.9
B.9
5.9
1.1
5.9
1.1
5.9
1.1
6"6"6"
6"
CL 1470CL 1470
W2W2
3
W2
W2
W2
W2COAT CL
2A5.2
1A5.2
UNIT SUMMARY
UNIT INTERIOR UNIT AREA
TYPE TOTALCOMMENT
UNIT 1 2-BEDROOM
UNIT AREA BALCONY
UNIT 2 3-BEDROOM
UNIT 3 2-BEDROOM
FLR
1
2UNIT 4
UNIT 5
UNIT 63
3-BEDROOM
2-BEDROOM
2-BEDROOM
NO.
1,542 67 1,609
1,415 62 1,477
1,200
1,750
67
67
62
62
1,626
1,305
1,267
1,812
1,693
1,367
NWALLS
PTD
SPACE NAMENO. BASEFLOORTYPECEILING(3)
E WS
PTDPTDPTD
(3)
HGTREMARKS
GWB PTDENTRY
LIVING ROOM
CLOSETS
CER.TILE
PTD
WOOD
WOOD
WOOD
PORC. TILE PORC. TILE
UNIT 1&UNIT 2
WOOD
DINING ROOM WOOD WOOD
BEDROOMS
PORC. TILE PORC. TILE
WOOD WOOD
BATHROOMS CER.TILE
CER.TILE
CER.TILE
KITCHEN WOOD WOOD
(1) PROVIDE COPPER PANS AT TUBS AND SHOWERS.(2) PROVIDE COPPER DRAINED OVERFLOW PAN BELOW WASHING MACHINES.(3) UNLESS OTHERWISE NOTED, WALLS AND CEILINGS VENEER PLASTER ON FIRE-RATED BLUEBOARD
PORC. TILE PORC. TILEELEVATOR.
PTD PTDPTD PTD
MECH / WD WOOD WOOD
STAIR WAY 1 GWBPTD
PLAM. PLAM. PLAM. PLAM. PLAM.
CORRIDOR
8'-5"
PTD PTDPTD PTD
GWBPTD
GWBPTD
GWBPTDVINYL
(1) JOHNSONITE "CUBIS"LANDINGS, TREADS, RISERS
VINYLSTAIR (1)
STAIR WAY 2
WOOD WOOD
7'-5"
8'-5"
7'-5"
8'-10"
8'-10"
8'-5"
WD COL1-HR RATED
ALIGN FINISH
WD COL1-HR RATED
3070
POCKET3070
3070
3070
3070
3070
3070
307030703070
PR1670PR1670 PR1670PR1670
POCKET3070
3070
3070
POCKET3070
POCKET3070
POCKET3070
POCKET3070
44
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
AMP
2nd & 3rd FLOOR PLANS,ROOF PLAN
AMP
A1.2
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
04.03.19 FOR PERMIT
RAISE BLDG / BPDA03/19/201RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
A B C
11'-0"20'-3"
10'-
0"
PROPERTY LINE (TYP)50'-0"
LANDSCAPE
VEST.
EXIST. CURB CUT
AA3.1
DA3.3
EXISTEL.16'-6"
15'-0"3'-3"
6'-0
"
PAVED WALKWAY
5'-0
"5'
-0"
DN
3'-1
"
E01
4'-2
"18'-0"
25'-0"
SLOPING WALKWAY SLOPE NTE 1:20 16'-9"
EXIST16'-5.5"
17'-0"
BA3.2
1
1.1
BA3.2
STEEL BEAMABOVE
PARKING
B.9
6"
PRO
PERT
Y LI
NE
(TYP
)
SIDEWALK
DNLEVELLANDING
5'-1
0"
4'-0"6'-3"
CONCRETE WALK,LANDING AND STEPS
CRUSHEDSTONE
GRANITECURB
PAVEDDRIVEWAY
DN
US MAILBOXES
INTERCOM
FACP
ROOF OVERENTRANCE
SLOPE UP - SEECIVIL DWGS FORELEVATIONS
CONC S.O.G.NOM. EL. 17'-6"CONTRACTORPROVIDE SLOPE TODRAIN AS REQUIRED
2
16'-4"
20'-
2"15
'-0"
COMPACT SPACE 7'-0" x 18'-0"
COMPACT SPACE 7'-0" x 18'-0"
INFILL CONCOPG. SEALJTS
LANDSCAPERETAININGWALL
9'-9
"
CANTILEVERWING ABOVE
STEP
UP
COMPACT SPACE 7'-0" x 18'-0"
NEW OPG AT EXISTFOUNDATION FOR
MAN DOOR
UP
18'-6"(MIN)
RLRL
3'-4
"
6
5.9
DA3.3
AA3.1
5
6"
E03
A B B.9 C
3'-3" 15'-0" 20'-3"6"
11'-0"
3'-4
"3'
-0"
3'-6
"
CONC WALKEL. 18'-0"
NEW OPG AT EXISTFOUNDATION FORGARAGE DOOR
EL. 17'-7"
WOODSTAIR
GRADE ATFOUNDATIONEL. 17'-6"
EL.17'-6"
STAIR LANDINGCOL ON CONCFTG (TYP)
CONC S.O.G.EL. 17'-6"
CONTRACTORPROVIDE SLOPE TODRAIN AS REQUIRED
PROPERTY LINE (TYP)
PRO
PERT
Y LI
NE
(TYP
)
PRO
PERT
Y LI
NE
(TYP
)
PERIMETERRETAININGWALL
WD WALK ATLEVEL OFREAR YARD
AREA DRAIN -SEE CIVIL
CRUSHEDSTONE
STEEL BEAMABOVE
1A3.4
LOWER CLGFOR STAIRLANDINGABOVE
2
2
LANDSCAPED REAR YARD
SEE CIVIL DWGS FOR STORMWATER RETENTION SYSTEM
WAP
ENLARGED PLANS
AMP
A1.3
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
1/4" = 1'-0"
F R O N T Y A R D P L A N
1/4" = 1'-0"
R E A R Y A R D P L A N1
2
03/19/20
03/19/20
RAISE BLDG / BPDA(1ST ISSUE)RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
1
EAST
6th
ST.
9'-1
0"9'
-10"
9'-1
0"
3'-6
"
RETAINIING WALL,VERIFY EXISTING
CONDITION ASREQUIRED
ELEV HOISTWAYMACHINE ROOMVENT PER CODE 1
A0.3SIM
ROOFTOPCONDENSERS
T.O. SLAB EL 17'-6"
STAIRDOOR
GARAGE
OWNER REPORTED WATERAT ELEV. 7'-0" ON 01.17.2019
ELEVATOR PIT BEYOND
1'-0" OF GRAVELUNDER FOOTINGS
1'-0" OF GRAVELUNDER FOOTINGS
1'-0" OF GRAVEL UNDER ELEVATOR PIT FOOTING.INSTALL METALLIC WATERPROOFING, SUBMIT SHOPDRAWINGS AND SAMPLES PRIOR TO INSTALLATION
7'-0" ELEVATORDOOR BEYOND
ENCASED STEEL COL (TYP)ALL COLS AND BEAMSFIREPROOFED AND ENCLOSED
WATER FOUND AT ELEV. 7'-0"
FRO
NT
LOT
LIN
E
REAR
LO
T LI
NE
1'-3" THICK FTG.W/ (6) -5# EW BOT @ HSS4x4x1/4" COLUMN
B.O. FOOTINGHIGH EL. 9'-0"
1 2 3 4 5 6
GR FLOOREL. 17'-6"
9'-8
"
TOP OFFOUNDATIONEL. 18'-3"
10'-0" 24'-2" 10'-8" 19'-0" 19'-6" 15'-6"
FRO
NT
LOT
LIN
E
20'-2"
WATER FOUND AT ELEV. 7'-0" WATER FOUND AT ELEV. 7'-0"
W16x50 BEYONDW24x104 BEYONDW12x65 BEYONDW12x22 BEYOND
STAIRWAY BEYOND
W24x68 BEYOND
ELEVATOR PIT EL. 5'-9"
B.O. FTG EL. 4'-6"ABANDON / REMOVEORIGINAL FOOTING
B.O. FOOTINGLOW EL. 7'-0"
T.O. FOOTING EL. 8'-9"
BOTTOM OF FOOTING AT LEFT SIDE BEYOND.AT ELEVATOR, MATCH BOTTOM OF FOOTINGELEVATION PROVIDE SLOPE TRANSITIONS PERTYPICAL DETAILS
BEAM ENCLOSUREBEYOND (TYP)
GWB BEAMENCLOSUREBEYOND (TYP)
BA3.2
BA3.2
CA3.2
STAIRWAYHEADHOUSE
ELEVATORMACHINE ROOMOVER ELEVATORHOISTWAY
ELEVMACHROOMDOOR
DWELLINGUNIT 1
DWELLINGUNIT 2
BEDROOMHALLWAY
BATH
LIVING
LIVING
LIVING
SLOPED ROOF TO DRAIN14 INCH PER FOOT
CA3.2
4
STANDING SEAMLEAD COATED COPPERPANELS
BRISE SOLEIL
1S1.1
1S1.1
AVG GRADEEL. 16.77'
OLD BASEMENT SLABHIGH EL. 11'-0"
VERIFY EXISTINGT.O.FOUNDATION
CEC-PROPOSED GRADEEL 18'-6"
BREAK UP / REMOVEORIGINAL FLOOR SLAB
EA3.4
XA3.X
3'-6
"3'
-6"
BALCONY
BALCONYBATH
BATH4
HALLWAY KITCHEN
DWELLINGUNIT 3
DWELLINGUNIT 5
CANTILEVEREDLVL BEAM
4.1
CANTILEVEREDLVL BEAM
LINE OF GARAGE DOOR BEHIND
MASTERBATH 1
WETBAR
KITCHEN
PANTRY
DWELLINGUNIT 4
HALLWAY BEDROOM
BEDROOM
4
4CL
DWELLINGUNIT6
HALLWAY
HALLWAY
HALLWAY
KITCHEN
HALLWAY
HALLWAY
DOORTO STAIR
DOORTO STAIR
5'-6"4'
-11"
MACH RM ROOF
8'-5
"
2A0.3
2A0.3
2A0.3
712
SGD
SGD
GL TRANSOM
SHELVES
SHELVES
SHELVES
2A0.3
2A0.3
2A0.3
1A0.3
4A0.3
1A0.3
39'-
11"
BUIL
DIN
G H
EIG
HT
DO
ES N
OT
EXCE
ED 4
0' (Z
ON
ING
CO
DE
COM
PLIA
NT)
GL TRANSOM
LINE OFADJACENTDRIVEWAY
NEW COLFOOTING
1'-3" THICK FTG.W/ (6) -5# EW BOT @HSS 4x4x1/4" COLUMN
CONC WALK NEXT TOBUILDING EL. 18'-0"
EXIST GRADE VARIESEL ±18.5' TO ±19.5'
BALCONY
SGD
GL TRANSOM
E07
E07
E07
7'-6" CLG
DOORTO STAIR
WHEEL BLOCK (TYP)
ELEV MACH RMEL. 61-7"
1st FLOORT.O. PLYWDEL. 27'-2"
2nd FLOORT.O. PLYWDEL. 37'-0"
3rd FLOORT.O. PLYWDEL. 46'-10"
ROOFT.O. PLYWDEL. 56'-8"
5.9
6"
1.1
6"
LANDSCAPERETAINING WALL
SLOPEDWALKWAY
3
1
GRAPHIC SCALE IN FEET8 1640
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
AMP/WAP
SECTION A
AMP
A3.1
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
FTG ELEVATIONS02/14/19
B U IL D I N G S E C T I O N A1/4" = 1'-0"
A
04/03/19 FOR PERMIT
RAISE BLDG / BPDA03/19/201RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
A B C
7'-1
"
SID
E LO
T LI
NE
SID
E LO
T LI
NE
B.O. FOOTINGHIGH EL. 9'-0"
9'-1
0"9'
-10"
AA3.1
AA3.1
DA3.3
DA3.3
SLOPINGDRIVEWAY
T.O. FOUNDATIONEL. 18'-3"
CANTILEVEREDWING BEYOND
LIVINGKITCHEN
BALCONY
MASTERBEDROOMLIVING
ELEVATORMACHINE ROOMOVER ELEVATORHOISTWAY BEYOND
STEP DOWNFOOTING ATELEVATORPIT BEYOND
STEP DOWNFOOTINGBEYOND
W2
SIM:DECKINGOVER EPDM
STANDING SEAMLEAD COATED COPPERPANELS
BRISE SOLEIL 3A6.1
BREAK UP / REMOVEEXIST CONC
9'-1
0"9'
-8"
ORIG BASEMENTHIGH EL. 11'-0"
LIVING
DWELLINGUNIT 3
DWELLINGUNIT 3
DWELLINGUNIT 1
DWELLINGUNIT 1
PARKING
KITCHEN
DWELLINGUNIT 5
DWELLINGUNIT 5
2A0.3
2A0.3
2A0.3
2A0.3
2A0.3
2A0.3
1A0.3
BALCONY
SIM:DECKINGOVER EPDM
1A0.3
SIM:DECKINGOVER EPDM
1A0.3
BALCONY
1A0.3
1A0.3
4A0.3
VESTIBULE
ROOF T.O. PLYWDEL. 56'-8"
T.O. CMUEL. 18'-3" 1'
-4"
T.O. FTGEL. 16'-11"5
A0.3
AZEK PANELS
E05
E05
E05
CANTILEVEREDWING BEYOND
C
C
B.9
T.O PARAPET
3'-0
"
FIRE PARTITION TOUNDERSIDE OF DECKABOVE (TYP)
6"20'-3"15'-0"3'-3" 11'-0"
3AA0.3
W14
GR FLOOR EL. 17'-6"
1st FLOORT.O. PLYWDEL. 27'-2"
2nd FLOORT.O. PLYWDEL. 37'-0"
3rd FLOORT.O. PLYWDEL. 46'-10"
INSULATED SLABAND SLAB EDGES
A B C
1'-0"
SID
E LO
T LI
NE
SID
E LO
T LI
NE
B.O. FOOTINGHIGH EL. 9'-0"
9'-1
0"9'
-10"
9'-1
0"9'
-8"
AA3.1
AA3.1
DA3.3
DA3.3
ELEVATORMACHINE ROOMOVER ELEVATORHOISTWAY
KITCHEN MASTERBEDROOM
LIVING
STEP DOWNFOOTING ATELEVATORPIT BEYOND
STEP DOWNFOOTINGBEYOND
W2
W1
STANDING SEAMLEAD COATED COPPERPANELS
3A6.1
ORIG BASEMENTHIGH EL. 11'-0"
SLOPINGDRIVEWAY
DWELLINGUNIT 1
ELEVATORSHAFT BEYOND
BREAK UP / REMOVEEXIST CONC
2-HR FIRERATED EXITACCESS
CL
1
DWELLINGUNIT 3
LIVING
DWELLINGUNIT 5
HALL WAYBEYOND
HALL WAYBEYOND
HALL WAYBEYOND
CLOSETDOORUNIT
DOOR
PANTRYDOOR
PARKING
KITCHEN
CANTILEVEREDWING BEYOND (TYP)
2A0.3
2A0.3
2A0.3
4A0.3
1A0.3
1A0.3
W2
3'-0
"
T.O PARAPET
8'-2
1 2"
VESTIBULE
2A0.3
ROOF T.O. PLYWDEL. 56'-8"
KITCHEN
PANTRYDOOR
B.9
FIRE PARTITION TOUNDERSIDE OF DECKABOVE (TYP)
6"20'-3"15'-0"3'-3" 11'-0"
INSULATED SLABAND SLAB EDGES
SLOPEINSULATIONTO DRAIN
4
3AA0.3
5A0.3
R-38 MIN
1st FLOORT.O. PLYWDEL. 27'-2"
2nd FLOORT.O. PLYWDEL. 37'-0"
3rd FLOORT.O. PLYWDEL. 46'-10"
GR FLOOR EL. 17'-6"
T.O. FOUNDATIONEL. 18'-3"
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
GRAPHIC SCALE IN FEET8 1640
AMP/WAP
SECTIONS B & C
AMP
A3.2
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
FOR PERMIT
B U IL D I N G S E C T I O N C1/4" = 1'-0"
C B U IL D I N G S E C T I O N B1/4" = 1'-0"
B
04.03.19
RAISE BLDG / BPDA03/19/201RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
1234
10'-8" 24'-2"19'-0"19'-6" 10'-0"
56
15'-0"
FRO
NT
LO
T LI
NE
ORIG BASEMENT
B.O. FOOTINGHIGH EL. 9'-0"
9'-1
0"9'
-10"
9'-8
"
B.O. FOOTINGLOW EL. 7'-0"
ELEC-MECH
W16x50 BEYOND
ELEV PIT EL. 5'-9"
ELEVATORDOOR
ELEVATORDOOR
STAIRWAYDOOR
CORRIDOR
CORRIDOR ELEVATORDOOR
ORIG ELEVATORPIT EL. 5'-9"
B.O. FTG EL. 4'-6"
CORRIDOR
W24x104 BEYOND
7'-8
"
BA3.2
1S1.1
CA3.2
BA3.2
CA3.2
STAIRWAYDOOR
STAIRWAYDOOR 1
S1.1
7'-8
"
MASTERBEDROOM
3'-0
"
T.O. PARAPET EL. 59'-8"
STAIRWAYHEADHOUSE
ELEVATOR MACHINE ROOMOVER ELEVATOR HOISTWAY
LIVING
KITCHEN
ELEV SHAFT VENTPER CODE
BRACE PARAPET ASREQUIRED
SLOPED ROOF TO DRAIN14 INCH PER FOOT
2-HR RATED FLOOR
2-HR RATED EXITENCLOSURE
4
STANDING SEAMLEAD COATED COPPERPANELS
13'-
0"UN
DER
SID
E O
F H
OIS
T BE
AM IN
ELEV
ATO
R H
OIS
TWAY
BEY
ON
D
1'-0
1 2"
TOP OF ELEVATORHOISTWAY BEYOND
8x24 HOIST BEAM+ 4 1/2" CLEARANCE
3A6.1
3A6.1
PARKING
4
ABANDONEXISTINGFOOTING
ABANDONEXISTINGFOOTING
BEDROOMCLOSET /STORAGE
4'-9"
LINE O
F 6'-8" M
IN
HEADROOM AT STAIR
STAIRWAY 21-HR FIRERATED
LINE O
F 6'-8" M
IN
HEADROOM AT STAIR
7'-7"
7'-7"
HALLWAY
CLOSETDOOR
DWELLINGUNIT 2
DWELLINGUNIT 4
HALLWAY
13'-11"
NEW COLFOOTING
1'-0
"
4.1
5'-6"
DOOR TOUNIT 6
EA3.4
EA3.4
4'-1
1"
ELEV MACH RMEL. 61-7"
ENTRY EL 18'-0
DWELLINGUNIT 3
STAIRWAY 21-HR FIRERATED
712
612"
HOIST BEAM BEYOND
2A0.3
2A0.3
SIDEWALK
2A0.3
2A0.3
2A0.3
SINGLE PLY ROOFINGON RIGID INSULSLOPED TO DRAIN
5'-4"
ELEVATORDOOR
39'-
11"
BUIL
DIN
G H
EIG
HT
DO
ES N
OT
EXCE
ED 4
0' (Z
ON
ING
CO
DE
COM
PLIA
NT)
AVGGRADEEL. 16.77'
STAIRWAYDOOR
8'-2
1 2"
VESTIBULE / MAIL 8'-1
5 8"
9'-1
0"
KITCHEN
8'-7
5 8"
DWELLINGUNIT 5
DWELLINGUNIT 1
3A A0.3
7'-6
"
OPEN TOBEYOND
OPEN TOBEYOND
1st FLOOR
GROUND FLRA0.35
A0.3
CUT DOWN EXISTFOUNDATION ASREQ'D FOR DOORAND SLAB INSUL.
SLAB BREAK & EDGEOF SLAB INSUL ATEDGE OF THERMALLYCONDITIONED SPACE(TYP)
NEW ELEVATORPIT EL. 12'-6"
ALL PARTITIONS ATALL STAIRS SHALL BEFIRE PARTITIONS TOUNDERSIDE OF DECKABOVE (TYP)
THRESHOLDEL. 18'-0"
A0.34
A0.3
SPRINKLERACCESSDOOR
4'-0
"
SLOPING FLOOR 1:26
STAIRCONTINUESBEYOND,2 RISERS
GROUND FLR EL 17'-6"
8'-2
34"
1.1
6"
5.9
6"
8'-2
1 2"
ROOFT.O. PLYWDEL. 56'-8"
4
4
13'-11" 5'-4"
7'-8
78"
4'-7"
512"
4
4
4
5A7.1
1
2-HR RATED EXITENCLOSURE
MAIL AND FACP
W1
STAIR 2CONTINUESBEYOND AS
EXTERIORSTAIR,
8'-5
"
ELEV MACHRM ROOF
13'-0" 6'-0"
1st FLOORT.O. PLYWDEL. 27'-2"
2nd FLOORT.O. PLYWDEL. 37'-0"
3rd FLOORT.O. PLYWDEL. 46'-10"
GRAPHIC SCALE IN FEET8 1640
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
AMP/ WAP
BUILDINGSECTION D
AMP
A3.3
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
FOR PERMIT
B U IL D I N G S E C T I O N D1/4" = 1'-0"
D
04.03.19
RAISE BLDG / BPDA03/19/201RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
A B C
1'-0"
8'-2
1 2"
SID
E LO
T LI
NE
SID
E LO
T LI
NE
ORIG BASEMENTHIGH EL. 11'-0"
B.O. FOOTINGHIGH EL. 9'-0"
9'-1
0"9'
-10"
9'-1
0"9'
-8"
1'-7
1 2"
AA3.1
AA3.1
DA3.3
DA3.3
DRIVEWAY
CANTILEVEREDWING
BEDROOM LIVING
PARKING
STEP DOWNFOOTING ATELEVATORPIT BEYOND
EXIT FOOTINGBEYOND VIF
W2
3A6.1
KITCHEN
STAIR 2
T.O. FOUNDATIONAS-BUILT EL. 18'-3"
7'-1
"
7'-0
"
DWELLINGUNIT 2
STAIR 2
KITCHEN
DWELLINGUNIT 4
STAIR 2BEYOND
DWELLINGUNIT 6
KITCHEN
LIVING
LIVING
1A0.3
2A0.3
2A0.3
2A0.3
ROOF T.O. PLYWDEL. 56'-8"
BREAK UP / REMOVEORIGINAL FLOOR SLAB
SLOPEINSULATIONTO DRAIN
B.9
T.O. FOUNDATIONAS-BUILT EL. 18'-3"
NEW COLFOOTING
6"20'-3"15'-0"
WHEEL BLOCK (TYP)
3'-3" 11'-0"
R-38 MIN
W2
6A6.2
1st FLOORT.O. PLYWDEL. 27'-2"
2nd FLOORT.O. PLYWDEL. 37'-0"
3rd FLOORT.O. PLYWDEL. 46'-10"
GR FLOOR EL. 17'-6"
4A0.3
6
B.O. FOOTING LOW EL. 7'-0"
4'-7"
1st FLOOR
GROUND FLR
2 EQ RISERS
5.9
INT. LANDING
1'-0
"
2A0.3
6"EXT. LANDING
3'-6"
(2) 24" DEEP LVLCUT TO FLUSHBOTTOM W/ 2x10's
2 LAYERS 58" F.C. GWBON 2x10's 16" OC.
STAIRWAY 21-HR FIRERATED ADJACENT
FLIGHT OFSTAIRS
6A0.3
GRAPHIC SCALE IN FEET8 1640
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
WAP
SECTION E
AMP
A3.4
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
B U I L D I N G S E C T I O N E1/4" = 1'-0"
ES E C T I O N at R E A R S T A I R1/4" = 1'-0"
1
RAISE BLDG / BPDA(1ST ISSUE)03/19/20
03/19/20
1RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
9'-1
0"9'
-10"
9'-1
0"
39'-
11"
AZEK ONE PIECEPAINTED SPANDREL,DO NOT SPLICE (TYP)
FOUNDATION BELOW GRADE
BALCONY
BALCONY
PRO
PERT
Y LI
NE
PRO
PERT
Y LI
NE
PRO
PERT
Y LI
NE
CAP FLASHING ON BUILT-UPAZEK CORNICE (TYP)
DRIVEWAY
A
6'-0" WOOD SLATPRIVACY FENCEBY OWNER
A
A
CB
3'-3" 15'-0" 20'-9" 11'-0"
APPROX GRADE AT SIDEWALK
ROOF
ORIG BASEMENT EL. 11'-0"
CANTILEVERED WINGSBEYOND
B.O. ORIG FTG EL. 9'-0" V.I.F.
OWNER REPORTED WATER AT ELEV. 7'-0" ON 01.17.2019
AVG GRADE EL. 16.77'
BUIL
DIN
G H
EIG
HT
DO
ES N
OT
EXCE
ED 4
0' (Z
ON
ING
CO
DE
COM
PLIA
NT)
ELEVATORMACHINE ROOMOVER ELEVATORHOISTWAY BEYOND
AA3.1
AA3.1
DA3.3
DA3.3
BRISE SOLIEL
W2
2nd FLOOR
1st FLOOR
3rd FLOOR
A
10'-
2"
WHITE CEDAR SHINGLES5" EXPOSURE STAINEDCOLOR SELECTION BY
ARCHITECT
WHITE CEDAR SHINGLES5" EXPOSURE STAINEDCOLOR SELECTION BYARCHITECT (TYP)
CLAD WOOD DOORS /WINDOWS BY MARVINOR EQUAL (TYP)
AZEK PAINTEDSPANDREL (TYP)
FENCE BY OWNER
VERTICAL CEDARSHIP-LAP SIDING STAINED
BALCONYB
B
B
K
JJ
E01
E05
39'-
8"BU
ILD
ING
HEI
GH
T AB
OVE
GRA
DE
PLAN
E (B
UILD
ING
CO
DE)
E05
E05
GROUND FLR EL. 17'-6"
C
C
B.9
HIGH POINT OFDRIVEWAY BEYOND
GUARD RAILING @WALKWAY BESIDEDRIVEWAY
STEPS UPTO ENTRY SLOPED
WALK TOENTRY
SLOPED WALKWAYAT BUILDING
ENTRYEL. 18'-0"
GRAPHIC SCALE IN FEET8 1640
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
AMP/WAP
FRONT ELEVATION
AMP
A4.1
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
1/4" = 1'-0"
F R O N T E L E V A T I O N
FOR PERMIT04.03.19RAISE BLDG / BPDA03/19/201RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
CLAD WOOD WINDOWSBY MARVIN OR EQUAL
BUILT-UPAZEK CORNICE
AZEK ONE PIECEPAINTED SPANDREL,DO NOT SPLICE
PRO
PERT
Y LI
NE
PRO
PERT
Y LI
NE
CLEA
R H
EIG
HT
(THESE WINDOWSSHOWN ON AN ANGLE)
EAST
6th
ST.
1 2 3 4 5 6
2nd FLOOR
1st FLOOR
ROOF
3rd FLOOR
OWNER REPORTED WATER ATELEV. 7'-0" ON 01.17.2019
B.O. FTG EL. 9'-0"
ORIG BASEMENT
ORIGINAL STEPFOOTING
B.O. FTG EL. 7'-0"
10'-0"
DRIVEWAY
EL. 17'-0"
BA3.2
BA3.2
CA3.2
CA3.2
CLAD WOOD SGD BYMARVIN OR EQUAL
1A6.1
1A6.1
EL. 17'-6"
DRIVEWAYHIGHPOPINTEL. 17'-10"
EL. 18'-6"EL. 17'-6"
56'-0"38'-10"
24'-2" 10'-8" 19'-0" 19'-6" 15'-0"
BALCONY
INSULATED OHSECTIONAL DOOR
DA3.4
DA3.4
8'-2
34"
GROUND FLREL. 17'-6"
STAIRWAY & MACHINEROOM HEADHOUSE BEYOND
VERTICAL CEDARSHIP-LAP SIDING STAINEDCOLOR SELECTION BYARCHITECT
VERTICAL CEDARSHIP-LAP SIDING STAINEDCOLOR SELECTION BYARCHITECT
VERTICAL CEDARSHIP-LAP SIDING STAINEDCOLOR SELECTION BYARCHITECT
WHITE CEDAR SHINGLES5" EXPOSURE STAINEDCOLOR SELECTION BY
ARCHITECT
EXIST EL.16'-5" VIF
EXTERIOR EGRESSSTAIR BEYOND SEEREAR ELEVATIONDWG A4.4
E
4.1
2'-6"
BALCONY
BALCONY
E
E
EE
ED
D
D
M
H
H
H E08
E02 E03
E08
E08
E09
E10CAP FLASHING ON BUILT-UPAZEK CORNICE (TYP)
5'-6"
5.9
6"
1.1
6"
RAILING @ WALKWAYBESIDE DRIVEWAY
DRIVEWAY GRADES INDICATED ARENOMINAL, PROVIDE POSITIVE SLOPETO DRAIN. SEE CIVIL DWGS.
GRAPHIC SCALE IN FEET8 1640
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
AMP
RIGHT SIDE ELEVATION
AMP
A4.2
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
R I G H T S I D E E L E V A T I O N1/4" = 1'-0"
FOR PERMIT04.03.19RAISE BLDG / BPDA03/19/201RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
CLAD WOOD DOORS/ WINDOWS BYMARVIN OR EQUAL
PRIVACY FENCEBY OWNER
PRO
PERT
Y LI
NE
PRO
PERT
Y LI
NE
WOOD SLATPRIVACY FENCEBY OWNER
2nd FLOOR
3rd FLOOR
1st FLOOR
RETAINING WALL
B.O. FTGEL. 7'-0"
RETAINING WALLSEE GEOTECHNICALCONSULT.DWGS. ES-1 & ES-2VERIFY AS REQUIRED
ABC
DRIVEWAY
AA3.1
AA3.1
DA3.3
DA3.3
GR FLOOREL. 17'-6"
3'-3"15'-0"20'-3"11'-0"
VERTICAL CEDARSHIP-LAP SIDING STAINED
COLOR SELECTION BYARCHITECT
WHITE CEDAR SHINGLES5" EXPOSURE STAINED COLORSELECTION BY ARCHITECT
AZEK ONE PIECEPAINTED SPANDREL,DO NOT SPLICE
ROOF
EXTERIOR STAIR OF NON-COMBUSTIBLEor WOOD CONSTRUCTION, SET BACK 10'FROM SIDE LOT LINE
AVG REAR YARDEL 18'-6"
G
E09
N
STAIR 2 INTERIORLANDING T.O.PLYWDEL. 26'-2"
CONC WALKEL 18'-0"
6'-8" VERTICAL CLEAR DIMENSIONFROM EDGE OF EXTERIOR STAIRTREAD LINE TO OPEN WINDOW
TWO INTERIOR7" MAX RISERS
EXTERIOR LANDINGEL. 25'-8"
6"
1'-0
"
CAP FLASHING ON BUILT-UPAZEK CORNICE (TYP)
AZEK ONE PIECEPAINTED SPANDREL,DO NOT SPLICE
4'-9" 7'-0" 7'-0"
GRADEAT BLDGEL 17'-6"
BOTTOM OF STEPSEL 17'-6"
LONG BOTTOMTREAD TO MATCHEL. OF REAR YARD
EL 18'-6"
B.9
6"
6"
1st FLOORT.O. PLYWDEL. 27'-2"
7'-2
"13
EQ
RIS
ERS
1A3.4
1A3.4
G G
G G G
G G
6"
GRAPHIC SCALE IN FEET8 1640
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
AMP
REAR ELEVATION
AMP
A4.3
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
R E A R E L E V A T I O N1/4" = 1'-0"
FOR PERMIT04.03.19RAISE BLDG / BPDA03/19/201RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
RETAINING WALLSEE GEOTECHNICAL CONSULT.DWGS. ES-1 & ES-2
PRO
PERT
Y LI
NE
FRO
NT
PRO
PERT
Y LI
NE
CLAD WOOD WINDOWSBY MARVIN OR EQUAL
6'-0" WOOD SLATPRIVACY FENCEBY OWNER
6 5 4 3 2 1
ORIGINAL ELEVATOR PITEL. 5'-9"
B.O. ELEVATOR PIT FTG EL. 4'-6"
ELEVATORSHAFTBEYOND
B.O. FTG EL. 9'-0"
B.O. FTG EL. 7'-0"
ORIGINAL STEP WALL FOOTINGS,VERIFY IN FIELD AS REQUIRED
LINE OF ORIGINALSLOPING BASEMENTFLOOR SLAB BEYOND
EAST
6th
STR
EET
B.O. WALL FTG NEARELEVATOR PIT EL. 5'-0"
2nd FLOOR
1st FLOOR
ROOF
3rd FLOOR
GR FLOOR
GRADE EL. 17'-6"
BA3.2
BA3.2
CA3.2
CA3.2
1A6.1
1A6.1
1st FLOOR
2nd FLOOR
ROOF
3rd FLOOR
15'-0" 24'-2"10'-8"19'-0"25'-0"
4.1
5'-6"
STAIRWAY &ELEVATOR MACHINEROOM HEADHOUSE
ELEV SHAFT VENTPER CODE
STANDING SEAMLEAD COATED COPPERPANELS
EA3.4
EA3.4
WHITE CEDAR SHINGLES5" EXPOSURE STAINEDCOLOR SELECTION BYARCHITECT
BASEMENT STORY WALL AREA = 918±SF X 15% =137 SF OPENINGS ALLOWED.
22'-0" 7'-6" 3'-0"
L L M M
F
F
F
2'-6"
CAP FLASHING ON BUILT-UPAZEK CORNICE (TYP)
GR FLR
1.1
6"6"
5.9
M M
ENTRY
ENTRY
G
G
G
G G
G G
G G
GRAPHIC SCALE IN FEET8 1640
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
AMP/WAP
LEFT SIDE ELEVATION
AMP
A4.4
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
L E F T S I D E E L E V A T I O N1/4" = 1'-0"
FOR PERMIT04.03.19RAISE BLDG / BPDA03/19/201RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
1-1/4"∅HANDRAIL
STAIR 1
3'-8
"
STAI
R W
IDTH
STAI
R W
IDTH
3'-8
"
1'-11"
1'-0"
CORRIDOR
2'-0
"5'
-8"
512"
1'-0"
CLEAR LANDING WIDTH
1'-11"
138"
ELEVATOR BASED ONOTIS GEN2 3500#
L1L3
L2L4
L CARC
gov
3070
B-LA
BEL
4'-2"
512"
6'-5"7 T @ 11"
1'-5"
19'-0" 512"
17 EQ R
214"
214"
B
3070
B-LA
BEL
4"
DN
UP 18 EQRISERS
CLOSET
1-HR FIRE RATED CORRIDOR
2-HR FIRE RATEDSTAIRWAY
1'-0
"
SHELVES
2'-7"
THRESHOLD
THRESHOLDTHRESHOLD
A
2 3 419'-0"10'-8"
1'-5"
COATS
MECH
5'-5
1 2"
6A
6
THRE
SHO
LD
THRE
SHO
LD
3070FIRE RATED
3070FIRE RATED
4
8"
SHELVES
SHELVES
WALLS TOUNDERSIDE OFDECK ABOVE
W2
4
4
6
6
F
DA3.3
DA3.3
DWELLINGUNIT 1
DWELLINGUNIT 2
DWELLING
4'-018"
5'-814"
5'-618"
ALIGN
3070
B-LA
BEL
FRONTSTAIR #1
EGRESS
STAI
R W
IDTH
3'-7
1 2"
UP 17EQ RISERS =±9'-10"
ELEVATOR BASED ONOTIS GEN2 3500#
L1L3
L2L4
L CARC
gov
7'-4"
9"
1'-4
5 8"
10'-8"
1'-0"
INSULMIN R-13
CONT INSULMIN 13.3
B
A
2 3
STEEL BEAM ABOVE
19'-0"
7'-1
112"
1'-0"
STEEL BEAM ABOVE
RISERS ABOVE -FIRE RATE 2-HRS TOSEPARATE UNDER-STAIRUSE FROM STAIRWAY
INSULMINR-20
512"
BOLLARD &GUARD (TYP)
VESTIBULE
1-1/4"∅HANDRAIL
8T @ 11"
2-HR FIRE RATEDSTAIRWAY
4
THRESHOLD
3070
B-LA
BEL
124'-2"
E01
6'-8"2'-9"9'-5"9'-5" 4'-0"
4"
4'-6
" MIN
CLE
AR
6"3'-0"
5'-8"
THRE
SHO
LD
8'-11"
6'-6
"
7'-5
1 8"
8" CMU orCONC BASE.T.O. MASONRY@ EL. 18'-3"
1'-0"
SLOPING FLOOR SLOPE NTE 1:25
512"
QUARTZ CAP
MECHANICAL /ELECTRICAL
SPRINKLER,WTR MTR
19'-0"
1.16"
E04
4
4
4
5
54
4
3070
B-LA
BEL
W2MMMM
PARKING
PARK
ING
5'-5
1 2"51
2"51
2"8"
1-HR FIRERATED STLCOLUMN
6'-0"
6
6
THRESHOLD
THRESHOLD
6'-4
5 8"
TO F
ACE
OF
CMU
TO F
ACE
OF
STUD
13'-0" 6'-038"
3'-1
134"
3'-1
134"
CL STAIRWAY
UP EL.17'-6"EL.18'-0"
UPPERLANDING
LOWERLANDING CORRIDOR /
ELEVATORWAITING
EL.17'-6"
EL.17'-6"INTERCOM
MAIL FACP
BA3.2
DA3.2
CA3.2
CA3.2
DA3.3
DA3.3
2
FRAMING DIM
1-HR FIRERATED STLCOL (TYP)
8
NTE
PTD MC12x10.6STRINGER (TYP)
7"
11"
2"
CONCRETEPAN TREAD
WITH WW MESH
FINISH AS SPECIFIED
4"
ANCHOR TOSTRUCTURE (TYP)
PTD MC12x10.6STRINGER AT LANDINGEDGE BETWEEN STRINGERS
5x5 TUBEWIDTH OFLANDING
3"
1'-0
"
1'-0
"
4"3"
5"
WW MESH
2 LAYERS5/8" GWB
ON MTLFRAMING
218"
2 LAYERS5/8" GWBON MTLFRAMING
PTD MC12x10.6STRINGER (TYP)
PTD MC12x10.6STRINGER (TYP)
WALL SURFACE
SEALANT
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
AMP AMP
A5.1
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
FOR PERMIT04.03.19
S T A I R 1 G R O U N D F L O O R P L A N1/2" = 1'-0"
S T A I R 1 1st F L O O R P L A N1/2" = 1'-0"
2
1
STAIR DETAIL (WD STAIR SIM)3
STAIR DETAIL (WD STAIR SIM)4
RAISE BLDG / BPDA03/19/201
STAIR 1FLOOR PLANS
RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
1-1/4"∅HANDRAIL
STAIR 1
3'-8
"ST
AIR
WID
THST
AIR
WID
TH3'
-8"
1'-11"
1'-0"
CORRIDOR
7'-1
112"
512"
1'-0"
1'-11"
138"
ELEVATOR BASED ONOTIS GEN2 3500#
L1L3
L2L4
L CARC
gov
3070
B-LA
BEL
4'-018"
512"
5'-618" 7'-4"
8 T @ 11"
1'-5"
19'-0" 512"
18 EQ R
214"
214"
B
DN
UP 18 EQRISERS
CLOSET
DWELLINGUNIT 4
1-HR FIRE RATED CORRIDOR
2-HR FIRE RATEDSTAIRWAY
1'-0
"
2'-7"
THRESHOLDTHRESHOLD
A
2 3 419'-0"10'-8"
6"
5'-5
1 2"
6A
6
THRE
SHO
LD
THRE
SHO
LD
3070FIRE RATED
3070FIRE RATED
4
8"
SHELVES
SHELVES
WALLS TOUNDERSIDE OFDECK ABOVE
W2
4
4
6
6
F
PANTRY/MECH /W-D
DWELLINGUNIT 4
DWELLINGUNIT 3
DWELLINGUNIT 3
LINENSHOWER
6"
ALIGN
PR 1670
PR 1670
DA3.3
DA3.3
CLEAR LANDING WIDTH
1-1/4"∅HANDRAIL
STAIR 1
3'-8
"ST
AIR
WID
THST
AIR
WID
TH3'
-8"
1'-11"
1'-0"
CORRIDOR
7'-1
112"
512"
1'-0"
1'-11"
138"
ELEVATOR BASED ONOTIS GEN2 3500#
L1L3
L2L4
L CARC
gov
3070
B-LA
BEL
4'-018"
512"
7'-4"8 T @ 11"
19'-0" 512"
18 EQ R
214"
214"
B
DN
UP 20 EQRISERS
CLOSET
1-HR FIRE RATED CORRIDOR
2-HR FIRE RATEDSTAIRWAY
1'-0
"
2'-7"
THRESHOLDTHRESHOLD
A
2 3 419'-0"10'-8"
6"
5'-5
1 2"
6A
6
4
8"
SHELVES
SHELVES
WALLS TOUNDERSIDE OFDECK ABOVE
W2
4
4
6
6
F
PANTRY/MECH /W-D
DWELLINGUNIT 6
DWELLINGUNIT 5
DWELLINGUNIT 5 SHOWER
3070
B-LA
BEL
THRESHOLD
4
8"4"
SHELVES
ALIGN
THRE
SHO
LD
3070FIRE RATED
PR 1670
PR 1670
DA3.3
DA3.3
8 T @ 11"
1'-5"
6"
CLEAR LANDING WIDTH
5'-618"
"XYPEX"WATERPROOFING
9'-1
0" MAIN STAIR NO.1
9'-1
0"
3'-0
"
ELEVATOROVERHEAD
COORDINATEEXACT SHAFTHEIGHT WITHAPPROVEDELEVATOROVERHEADREQUIREMENT
13'-
0"CL
EAR
HEI
GH
T BA
SED
ON
OTI
S G
EN2
ELEV HOISTWAYVENT PER CODE
FLAT ROOF2% SLOPE
UNIT 5
ELEVATORHOISTWAY
2 3 4
4A0.3
3A0.3
TYP
2A0.3
1A0.3
1A0.3
SIM
6
4
WATERMTR /SPRINKLER
GRAPHIC SCALE IN FEETORIGINAL SCALE 1/4"=1'-0"
420 1 3 8
19'-0"10'-8"
UNIT 3
UNIT 1
9'-1
0"9'
-10"
9'-1
0"9'
-8"
2ndFLOOR
ROOF
3rdFLOOR
1stFLOOR
6
5
GROUND FLOOREL. 17'-6"
PARKING
UNIT 2
PARKING
HOIST BEAM
ELEVATOR PIT
5'-0
"
ELEVATORMACHINEROOM
UNIT 4
UNIT 6
MACH RM ROOF
7'-7
"
ELEV MACH RMEL. 61-7"
4'-1
1"
ELEVPIT
ORIGELEVPIT
8'-5
"
9'-1
0"
3'-1
112"
LINE O
F 6'-8" M
IN HEADROOM AT STAIR
10'-
11"
LINE O
F 6'-8" M
IN HEADROOM AT STAIR
LINE O
F 6'-8" M
IN HEADROOM AT STAIR
20 EQ RLIN
E OF 6
'-8" MIN HEADROOM AT ST
AIR
3'-0
"3'
-0"
3'-0
"3'
-6"
LINE OF 6'-8" MIN HEADROOM AT STAIR
12 7
1A0.3
SIM
R-10 EDGE-OF-SLABINSUL DEPTH =2'-0"
REMOVE ORIGFLOOR SLAB
ORIG. PITFOUNDATIONTO REMAIN
COMPACTED FILLAS REQUIRED
8
18 E
Q R
18 E
Q R
17 E
Q R
19 E
Q R
4
W1
CURB ATDOOR
3'-6
"
TOTAL R-49
6A
5A0.3
3'-0
"3'
-0"
3'-0
"
3'-0
"
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
WAP
STAIR 1PLANS & SECTION
AMP
A5.2
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
S T A I R 1 2nd F L O O R P L A N1/2" = 1'-0"
S T A I R 1 3rd F L O O R P L A N1/2" = 1'-0"
S T A I R 1 S E C T I O N1/4" = 1'-0"
1
23
RAISE BLDG / BPDA(1ST ISSUE)03/19/20
03/19/20
1RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
BANK RUN SAND &GRAVEL BACKFILL
GRACE PROCOR FLUID APPLIEDMEMBRANE INTO FACE OF
WALL EXTENDED FROM GRADETO BOTTOM OF FOOTING
1.5" RIGID INSULATION R=7.5
1 1/2"=1'-0"WALL SECTION
6 MILPOLYETHYLENE (TYP)
R-5 RIGIDINSULMIN 6" TAMPEDCRUSHED STONE
6" TAMPED CRUSHEDSTONE.
"R-30" INSULATION INTHE FIRST 24" (MIN)
"R-30" INSULATION INTHE FIRST 24" (MIN)
3rd FLOOR
PARKING
1st FLOOR
2nd FLOOR
"R-30" INSULATION
MILL FINISH ALUMIN. CAPFLASHING TYP.
@ ROOF PERIMETER
FINISH MATERIAL AS SPECIFIED
5/8" CDX EXT. SHEATHINGOVERLAP FOUNDATION 1" MIN.
AIR BARRIER - TYVEK
60 mil FULLY-ADHERED EPDM ROOFMEMBRANE, PITCH MIN. 1 / 4 " PER FOOT
2A0.3
2A0.3
2A0.3
1A0.3
4A0.2
3'-0
"
ROOF
9'-8
"
BANK RUN SAND & GRAVEL BACKFILL
GRACE PROCOR FLUID APPLIEDMEMBRANE INTO FACE OF WALL
EXTENDED FROM GRADE TOBOTTOM OF FOOTING
1.5" RIGID INSULATION R=7.5
2 3/4"=1'-0"DETAIL @ FOUNDATION W/ SLABCONDITION
6 MILPOLYETHYLENE (TYP)
MIN 6" TAMPEDCRUSHED STONE
6" TAMPED CRUSHEDSTONE.
1st FLOOR2 2x6 PT SILLS SECURE W/
SIMPSON STRONGTIE HD5AHOLDDOWNS OR EQUAL
APPROVED BY ARCHITECTPER SEISMIC CODE REQ.
1/2" DIA. GALV.ANCHOR 6'-0" o.c.
SILT SCREEN ANDCRUSHED STONE BACKFILL
4" PERFORATEDPVC FOUNDATION
DRAINDRAIN SHALL BE
PLACED AT 45% ANGLETO EDGE OF FOOTING
GRADE VARIES
STUCCO COLORTO BE SELECTED
BY ARCHITECT
SEE STRUCTURALDRAWINGS FOR
CONCRETE WALL,FOOTINGS &
REINFORCINGBARS
BASEMENTOR CRAWL SPACE
see plans for specifics
5/8" TYPE "X" GWB. HORIZONTAL PTD.R-19 BATT INSULATION2 x 6 WOOD STUDS @ 16" o.c.
3/4" T&D PLYWOOD DECKING (TYP)3/4" T&G WOOD FLOORING OR TILE(see finish schedule for specific condition)
1 x 4 WOOD BASE W/ CONTIN. BLOCKING
1 x 8 TRIM W/ CONTIN.METAL FLASHING
1 1/2" PERIMETER INSULATIONEXTEND MIN 2'-0" BELOW GRADE
2A0.3
FIBER CEMENT CLAPBOARDSIDING - PAINTED
HARDIE PLANK - SMOOTH SIDE OUT
5/8" CDX EXT. SHEATHINGOVERLAP FOUNDATION 1" MIN.
AIR BARRIER - TYVEK
TOP OF CONC.G
RAD
E VA
RIES
SEE
SITE
PLA
NS
"R-30" INSULATION
5A0.3
GR FLOOR
3 3/4"=1'-0"WALL SECTION @ ROOF CONDITION
3 / 4" P.T. T&G PLYWOOD DECKING
TAPERED RIGID INSULATION: MIN. 3"
1/2" CDX EXT. SHEATHING
MILL FINISH ALUM CAPFLASHING ON 5/4" AZEK, TYP.
@ ROOF PERIMETER
APPROVED WINDOW SYSTEM -SEE ELEVATIONS FOR TYPE
AND DIMENSIONS
ROOF T.O. PLYWD EL. 56'-8"
60 mil FULLY-ADHERED EPDM ROOFMEMBRANE, PITCH MIN. 1 / 4 " PER FOOT
1A0.3
BUILD FULL SIZEMOCK-UP FORARCHITECT'SAPPROVAL
5/4" TYPE X DENSGLASSWITHIN 10' OF PROPERTY LINE
3'-0
"
5/4" AZEK PANEL PAINTED
6"1'
-0"
GARAGE DOOR ELEVATION
WALL SECTION 4
1st FLOORT.O.PLYWDEL. 27'-2"
8'-2
1 2"
INSUL R-30
SECTIONAL O.H. DOOR
NEW PAVEDDRIVEWAY
4.2
STL BEAM HEADER &STL COL. IN WALL
9"
4"7"
PARGEDCONCRETE
AZEKTRIM
WHITECEDARSHINGLESSTAINED
AZEKTRIM
VERT. CEDARBOARDSSHIPLAP
1'-8
"7'
-51 2"
9"
9'-8
"
APPROXIMATE VERTICALDIMENSIONS OF TRIMBOARDS, ADJUST INFIELD AS REQUIRED TOPROVIDE INDICATEDAND REQUIREDALIGNMENTS
SINGLE MEMBRANEROOFING ON SLOPETO DRAIN
WOOD DECKING ATSAME ELEVATION ASINTERIOR FLOOR
CANTILEVERED LVL's,SEE STRUCTURAL
1x6 T&G MAHOGANY,STAPPING, 58" FC GWB,12" PLYWOOD
TOP OFFOUNDATIONEL. 18'-3"
GARAGEEL. 17'-6"
ADD FRAMING ASREQUIRED FOR LEVELINTERIOR FLOOR
CONTINUOUSVAPOR PERMEABLEAIR BARRIER
TYPICAL FINISHFLOOR SYSTEM
GARAGEEL. 17'-6"
2
2
2
2
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
2RAISE GROUND FLOORTO EL 17'-6" / RE-ISSUE
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
AMP AMP
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
A6.1WALL SECTIONS
FOR PERMIT04.03.19
RAISE BLDG / BPDA03/19/201RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
6"
7'-0
"1'
-25 8"
UNIT 102
INSUL R-30
CONTINUOUSAIR/WEATHER BARRIERON SHEATHING (TYP)
SECTIONAL O.H. DOOR
NEW PAVED DRIVEWAY
PKG DRIVEWAY
C
SID
E LO
T LI
NE
7'-9"
CANTELEVER OVER DRIVEWAY
6"
8'-2
5 8"
INSUL R-30
CONTINUOUSAIR/WEATHER BARRIERON SHEATHING (TYP)
NEW PAVED DRIVEWAYEL. VARIES - SEE CIVIL
PKG DRIVEWAY
C
7'-9"
TOP OF (EXIST)FOUNDATIONEL. 18'-3"
TOP OF (EXIST)FOUNDATIONEL. 18'-3"
CONTINUOUSAIR/WEATHER BARRIERON SHEATHING (TYP)
PROJECTING WING OVER GARAGE DOOR
B.9 B.9
RECESSED LIGHT FIXTURE
W2W2
W1
CANTELEVERED BEAMS
2A0.3
2A0.3
WALL SECTION 5WALL SECTION 6
SID
E LO
T LI
NE
3'-3" 3'-3"
9'-8
"
1st FLOORT.O.PLYWDEL. 27'-2"
GARAGE EL. 17'-6"
9'-8
"
1st FLOORT.O.PLYWDEL. 27'-2"
GARAGE EL. 17'-6"
2
2
2
2
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
WAP AMP
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
A6.2WALL SECTIONS
RAISE BLDG / BPDA(1ST ISSUE)03/19/20
03/19/20
RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
1
5x54"7"
5
9"
AZEK TRIM ONPLYWD SHEATHING
STL BEAMHEADER ABOVE
COL FOR STL BEAMHEADER ABOVE -SEE STRUCTURAL
LINE OF COLBASEPLATE BELOW
CANTILEVERED BEAM(4) 13
4"x14" LVL
SPRAY-ONFIREPROOFING
LVL BEAM SUPPORT
SECTIONALO.H. DOOR
WD CAP ON CONCBELOW
B.9 C
6"
1'-0
"
1'-0"
1'-6"
1'-0
"
G
15x5
GARAGE AREA 2 114
1'-2"4"8"
1'-7"1'-6"1'-6"1'-6"
4"4"4"4"4" 8"8"8"8"
GALV./PTDUNISTRUT 2" VER.SUPPORT
BIRD SCREEN (TYP)
GALV./PTD STEELPLATE ON CONC
EDGE OFCONC HIGHWALL BELOW
TYPICAL 4" OPGSEE BUILDINGELEVATIONS
GALV./PTDUNISTRUT 2" HOR.SUPPORT
8"
O.H. GARAGE DOOR
SPRAY-ON FIREPROOFING ONSTEEL FRAMING2-HR FIRE RATING(TYP)
W1
EDGE OF CONCHIGH WALL BELOW(TYP)
COL BASE PLATE - SEESTRUCTURAL (TYP)
1'-0
"
1'-0"
1'-6"
1'-0"6"
5x5
GARAGEAREA 1 113
W1
1'-0"
1'-6"
1'-0"6"
5x5
W1
W2
W11
17A6.6
1'-0
"
1'-0"
1'-6"
1114"63
8"
4"
5x5
10 STL STUDS
3"
W2
5x5
5"
COL 2-HR RATED
958"
8"
B
5
1'-0
"
REARSTAIR #2 111
W11
W3
GARAGEAREA 1 113
EDGE OFCONC BELOW
EDGE OFCONC BELOW
58" GWB ON 35
8" STLSTUDS 16" OC
1'-0
"5"
SPRAY-ON FIREPROOFINGAS REQUIRED TO ACHIEVEFIRE RATING
10" STLSTUDS
F
7
8"
5x5
ENTRY LOBBY 102
W2 R-7.5 RIGID INSULAT COL (TYP)
1'-0
"5"5x5
738"
8" W2
11"
W9
1"5"
R-7.5 RIGID INSULAT COL (TYP)
1'-2"
4
7"7"
4"
3"
ARCHITECTURALCONCRETEENCASEMENT PTD2-HR FIRE RATING
HSS 6x6x38 STL COL
BASE PLATE ANDBOLTS BELOW
CONCRETE-ENCASED COLUMN2-HR RATED
C
2NO REVISION,RE-ISSUE ONLY
DETAILS
AMP
A7.1
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
COL @ GARAGE DOOR1 1 1/2"=1'-0"
5
OPEN BRICK VENT AT GARAGE - PLAN VIEW2 1 1/2"=1'-0"1 1/2"=1'-0"
6 1 1/2"=1'-0"1 1/2"=1'-0"1 1/2"=1'-0"
1 1/2"=1'-0"11 1 1/2"=1'-0"1st FLOOR COL10 1 1/2"=1'-0"9 1st FLOOR COL
1st FLOOR CORNER - PLAN VIEW3
7 STAIRWAY # 2 - 1st FLOOR PLAN DETAIL COL AT PARKINGSTAIRWAY # 1 - PLAN DETAIL
16-297
874 East Sixth St.South Boston 02127
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
AMP
FOR PERMIT04.03.19
1
1
RAISE BLDG / BPDA03/19/20RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
FLOOR EL.T.O. PLYWD
10"
LEDGER & JOISTHANGER - SEESTRUCTURAL
8
8
2A0.3
HALLWAYBATH
HALLWAY
DBL TOPPLATE (TYP)
BATH
HIGH-PERFORMANCEACOUSTIC CLIP (TYP)
ACOUSTIC SEALANTAT GWB EDGE (TYP)
2A0.3
HIGH-PERFORMANCEACOUSTIC CLIP (TYP)
PERIMETER ISOLATIONSTRIP CUT FLUSH TOPWITH LEVELINGCONCRETE TOPPINGSYSTEM (TYP)
FLOOR EL.T.O. PLYWD
1'-214"
2A0.3
10
BATH
BATH
BATH
BATH
10
DBL TOPPLATE (TYP)
SEE TYPICAL NOTESDET 1/A7.2
2A0.3
FLOOR DECK
FIRE RATEDFLOOR/CEILINGASSEMBLY
FLOOR EL.
2A0.3
LIVING
LIVING
LIVING
LIVING
9
9 SEE TYPICAL NOTESDET 1/A7.2
1'-5
3 8"
OMIT ACOUSTIC CLIPSFROM WALL AT FLOOR
FLOOR EL.
2A0.3
DWELLING UNIT
DWELLING UNIT
STAIRWAY
6
6
2-LAYERS GWBBETWEEN STUD WALLAND LEDGER
DBL TOPPLATE (TYP)
SEE TYPICAL NOTESDET 1/A7.2
7
G
238"
5"
718"
TOP OF PROJECTINGALUM BANDING
SEALANT & BACKERROD (TYP)
1st FLOOR EDGEOF SLAB BELOW
STEEL COLUMNSEE STRUCTURAL
C2SIM
STEEL COLUMN AT1st FLOOR BELOW APPROVED
WINDOWSYSTEM
1'-0
"
1'-0"
LIVING
PTD GWB ONLVL POST
SIM OPPHAND AT "A"
2A0.7
2A0.7
1'-0
"
F
7
LIVING
512"
10"
1'-0"
414"
SIM
SIM OPPHAND AT "A"
SEALANT &BACKER ROD(TYP)
8"
APPROVEDWINDOWSYSTEM
PTD GWB ONLVL POST
EDGE OF 1stFLOOR WALL
BELOW
2A0.7
1
2NO REVISION,RE-ISSUE ONLY
WAP
DETAILS
AMP
A7.2
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
1 1 1/2"=1'-0"23 1 1/2"=1'-0"4 1 1/2"=1'-0" 1 1/2"=1'-0"SECTION DETAIL - DWELLING UNIT SEPARATIONMIN 1-HR FIRE RATED
SECTION DETAIL - DWELLING UNIT SEPARATION at BATHSMIN 1-HR FIRE RATED
SECTION DETAIL - DWELLING UNIT SEPARATIONMIN 1-HR FIRE RATED
SECTION DETAIL - FIRE BARRIER CONSTRUCTIONAT STAIRWAY ENCLOSURE MIN 2-HR FIRE RATED
6 1 1/2"=1'-0"PLAN DETAIL - CORNER AT PROJECTING BAY7 1 1/2"=1'-0"
PLAN DETAIL -
10/31/18
16-297
874 East Sixth St.South Boston 02127
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
FOR PERMIT04.03.19
RAISE BLDG / BPDA03/19/20RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
STRUCTURAL NOTES - GENERAL:1. DESIGN CONFORMS TO THE EIGHTH EDITION RESIDENTIAL CODE WHICH CONSISTS OF THE FOLLOWING: INTERNATIONAL RESIDENTIAL CODE 2009 (IRC). MASSACHUSETTS AMENDMENTS (MA)
2. CONTRACTOR SHALL VERIFY THAT ALL DIMENSIONAL CONTROLS ARE ADEQUATE PRIOR TO CONSTRUCTION.
3. CONTRACTOR SHALL VERIFY THAT ALL APPLICABLE PERMITS ARE IN PLACE PRIOR TO START OF CONSTRUCTION.
4. STRUCTURAL ENGINEER MUST BE CONSULTED FOR ANY CHANGES TO BEARING WALL LOCATIONS, FRAMING, MEMBER SIZES, FOUNDATION OR DETAILS SHOWN ON THESES DRAWINGS.
5. ALL STRUCTURAL MATERIALS / MEMBERS SHALL BE FREE FROM DEFECTS THAT MAY REDUCE THEIR STRUCTURAL CAPACITY.
6. CARE MUST BE TAKEN TO ENSURE THE CONCRETE CORE OF ALL "LALLY" COL'S REMAINS INTACT.
7. ANY HEADERS OR OTHER STRUCTURAL ELEMENTS NOT SPECIFICALLY ADDRESSED ON THESE PLANS SHALL BE INSTALLED IN ACCORDANCE WITH THE ABOVE LISTED CODES OR BROUGHT TO THE ATTENTION OF THE STRUCTURAL ENGINEER OF RECORD (SER).
8. ALLOWABLE SOIL BEARING PRESSURE = 1.5 ksf. CONTRACTOR SHALL VERIFY SUITABILITY OF SOIL.
8. LOADING: V = 100 mph (WIND); Pg = 40 psf (GROUND SNOW); SEISMIC: N/A
CONCRETE SLAB NOTES:1. MINIMUM SLAB THICKNESS TO BE 4" AT WALKWAYS, 5" AT GARAGE AND DRIVEWAY, UNLESS OTHERWISE INDICATED ON THE DESIGN DRAWINGS.
2. SLAB CONCRETE COMPRESSIVE STRENGTH MIN. 4,000 PSI AT 28 DAYS.
3. SLABS EXPOSED TO THE WEATHER SHALL BE AIR ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) SHALL NOT BE LESS THAN 5% NOR MORE THAN 7%.
4. ALL TOP SOIL, ORGANIC AND FOREIGN MATERIAL MUST BE REMOVED FROM BELOW PROPOSED SLAB DEPTH. FILL WITH CLEAN SAND, GRAVEL OR CRUSHED STONE. FILL MUST BE COMPACTED IN MAXIMUM 8" LIFTS. TOTAL FILL SHALL NOT EXCEED 24" WITHOUT CONTACTING SER.
5. MINIMUM 4" COMPACTED SAND, GRAVEL OR CRUSHED STONE BASE BELOW SLAB UNLESS EXISTING SUBGRADE IS SAND-GRAVEL SOILS CLASSIFIED AS GROUP I ACCORDING TO USCS.
6. INTERIOR SLABS MUST HAVE A MINIMUM 12 MIL VAPOR BARRIER PER 780 CMR 5506.2.3 DIRECTLY BELOW THE SLAB.
7. ALL SLABS MUST BE REINFORCED WITH 6X6-W1.4XW1.4 WWF. PLACE WWF AT MID-HEIGHT FOR 4" SLABS AND 1/3 OF SLAB DEPTH FOR THICKER SLABS (EG 3" FOR 9" SLAB).
8. 1/4 DEPTH SAW CUT CONTROL JOINTS MUST BE INSTALLED AT 30'-0" OC MAX. IN EACH DIRECTION OR AS SHOWN ON PLANS.
9. ALL SLABS MUST BE PLACED IN ACCORDANCE WITH ACI 318-02.
10. RESIDENTIAL SLABS-ON-GRADE SHALL COMPLY WITH 780 CMR 5506.
FOUNDATION NOTES:1. FOOTING AND WALL CONCRETE COMPRESSIVE STRENGTH SHALL HAVE A MIN. 3,000 PSI AT 28 DAYS.
2. PLACE CONCRETE IN ACCORDANCE WITH ACI 318-02.
3. MIN. SOIL BEARING CAPACITY SHALL BE 3,000 PSF.
4. WALL LOCATION SHALL BE STAKED BY A PROFESSIONAL SURVEYOR PRIOR TO CONSTRUCTION IF REQUIRED.
5. FOR ALL FOOTINGS, EXCAVATE TO THE BOTTOM-OF-FOOTING ELEVATIONS LEAVING THE SOIL BELOW UNDISTURBED.
6. FOOTINGS MUST BE FOUNDED ON VIRGIN SOIL. IF UNSUITABLE MATERIAL EXISTS AFTER EXCAVATION, CONTACT ARCHITECT AND SER.
7. NO MATERIAL MAY BE PLACED BELOW FOOTINGS WITHOUT PERMISSION OF THE ARCHITECT OR SER.
8. BACKFILL FOUNDATION WALL 4'-0" MAX. UNTIL THE FIRST FLOOR FRAMING IS COMPLETED.
9. 1/2" DIA ANCHOR BOLTS WITH A MIN. 8" EMBED INSTALLED IN ACCORDANCE W/ 780 CMR 5403. BOLTS SHALL BE 6' OC MAX WITH A MIN OF 2 BOLTS PER PLATE. BOLTS MUST BE INSTALLED A MAX OF 12" AND A MIN OF 5" FROM END OF EACH PLATE.
10. ALL REINFORCING BARS SHALL BE EPOXY COATED 60 KSI DEFORMED BARS.
WOOD / FRAMING NOTES:1. ALL STANDARD SAWN LUMBER EXPOSED TO WEATHER, IN CONTACT WITH THE GROUND OR IN CONTACT WITH CONCRETE SHALL BE "PRESSURE TREATED" SOUTHERN YELLOW PINE NO. 1 OR BETTER.
2. ALL STANDARD SAWN LUMBER NOT EXPOSED TO WEATHER SHALL BE HEM-FIR NO. 1 OR BETTER.
3. ALL BUILT-UP MEMBERS SHALL BE FASTENED TOGETHER BY 2 ROWS OF 16d @ 12" OC MINIMUM UNLESS OTHERWISE REQUIRED BY MANUFACTURER.
4. ALL LVL MATERIAL: fb = 2,800 PSI, 2.OE MIN.
5. ALL- I JOISTS MUST BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S GUIDELINES.
6. ALL STEEL CONNECTORS MUST BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS GUIDELINES AND SUPPLIED AS SPECIFIED ON THE DRAWINGS AS APPLICABLE.
7. ALL WALLS RUNNING PARALLEL TO JOISTS SHALL BE SUPPORTED BY BLOCKING @ 16" OC OR DIRECTLY BY A DOUBLE JOIST.
8. SOLID BLOCKING SHALL BE INSTALLED BELOW LOAD BEARING WALLS & OVER BEAMS.
9. CARE MUST BE TAKEN TO SUPPORT ALL COLUMN / POINT LOADS WITH SOLID BLOCKING AS NEEDED.
10. ALL BEAMS MUST BE SUPPORTED BY (2)-2X4 BUILT-UP COLUMN MIN. UNLESS OTHERWISE NOTED.
11. LVL BEAMS SHALL BE SUPPORTED FULL WIDTH X 3" END BEARING DEPTH.
12. METAL CONNECTORS: SIMPSON OR APPROVED EQUAL.
13 FLOOR AND FLOOR SUPPORT FRAMING: SUBMIT SHOP DWGS PREPARED AND STAMPED BY A STRUCTURAL ENGINEER REGISTERED IN MASSACHUSETTS.
STEEL NOTES:1. ALL STEEL BEAMS AND COLUMNS, EXCEPT TUBE STEEL, SHALL BE 50 KSI.
2. ALL TUBE STEEL BEAMS AND COLUMNS SHALL BE 46 KSI.
3. ALL MISC. STEEL PLATES SHALL BE 36 KSI MIN.
4. ALL WELDING SHALL BE PERFORMED BY QUALIFIED PERSONNEL.
5. ALL BOLTS TO BE A325 3/4" DIA.
6. ALL BOLTED CONNECTIONS SHALL BE BEARING TYPE.
7. SIMPLE CONNECTIONS THAT ARE DESIGNED BY FABRICATOR SHALL BE APPROVED BY ARCHITECT AND SER.
S0.1
STRUCTURALGENERAL NOTES
AMP
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
AMP
FOR PERMIT01/29/19
01/29/19
16-297
874 East Sixth St.South Boston 02127
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
FOR PRICING04/01/19
04/03/19 FOR PERMIT
REISSUE (RAISE BLDG)03/19/20
REISSUE (RAISE BLDG)05/15/20
AT OPENINGS ANDDISCONTINUOUS ENDS
"U" BARS
CLASS B SPLICE
TYPICAL PLAN OF HORIZONTAL WALL REINFORCING
STD. HOOK(1'-0" MIN.)
CLAS
S B
SPLI
CE
WATERSTOP(WHERE
REQUIRED)
CLASS B SPLICE
CLAS
S B
SPLI
CE
IF CONSTRUCTION JOINT EXISTS AT CORNERS
AT CORNERS
WATERSTOP(WHERE REQUIRED)
AT INTERSECTIONS
(1'-0" MIN.)STD. HOOK
CLAS
S B
SPLI
CE
CONTINUOUSKEY
NOTE:
VERTICAL REINF. BARSARE NOT SHOWNFOR CLARITY (TYP.)
CLASS B SPLICE
AT CONSTRUCTION JOINTS
CLAS
S B
SPLI
CE
STD.
HOOK
(TYPIC
AL)
AT BEND
HORIZONTALBARS CONTINUOUS
KEY
WATERSTOP(WHERE REQUIRED)
HORIZONTALBARS
HORIZONTALBARS
HORIZONTALBARS
#5 @ 48" (alternate hooks)NON-BEARING MASONRY(THICKNESS >8") OR BEARINGSTUD WALL
CONTINUOUS TRENCHFOOTING AT CMU WALLS
1
VAPOR BARRIER8"8"
2-#5 x CONTINUOUS
FILL REINFORCEDCELLS OF CMU SOLIDW/ GROUT
1
1'-0
"
REFER TO MECHANICAL DRAWINGSFOR SIZE AND LOCATION OF PADS
W.W.F. (REFER TO GENERALNOTES FOR SIZE)
ROUGHEN CONCRETE SLAB ANDCOAT W/ EPOXY BONDINGAGENT PRIOR TO POURING PAD.
HOUSEKEEPING PAD
2" CLR. (TYP.)
1-#4 X CONTINUOUS (ALLAROUND) 1-#4 X CONTINUOUS (ALL
AROUND)
SLAB DEPRESSION
DEPTH OF DEPRESSION
6" VAPOR BARRIER (IFREQIURED)
2
1
1-#4 X CONTINUOUSALL AROUND
2" CLR. (TYP.)
AS REQUIREDBY MECHANICALCONSULTANT VAPOR
BARRIER (IFREQIURED)
PROVIDE REGLET(WHERE REQUIRED)
1-#4 X CONTINUOUSALL AROUND
#3 @ 12"(TYPICAL ALL AROUND)
TYPICAL VERTICAL WALLCONTROL JOINT
WALL REINFORCING[OUTSIDE]
[INSIDE]
1-1/2"
T/3
WATERSTOP (WHEREREQUIRED)
SAME SIZE AND SPACING ASHORIZONTAL REINFORCING (80DIAMETERS LONG)
1/2"
3/4"
3/4"
T
1
2
FOOTINGREINFORCING
"D"
SPLICE LENGTH
MIN.
"D"
FOOTING REINFORCING
SPLICE LENGTH
1'-0"
PROVIDE 1 BAR AT EACH FACE TOMATCH HORIZONTAL WALLREINFORCING
HORIZONTALWALL REINFORCING
MAX
IMUM
2'-0
"
MINIMUM4'-0"
1'-0"
ELEVATION OF CONTINUOUS STEPPED WALL FOOTING
VARIES
RELATIONSHIP OF FOOTINGS AT DIFFERENT ELEVATIONS
UPPER FOOTING
LOWER FOOTING
2
1
THE VERTICAL OFFSETOF ADJACENTFOOTINGS SHALL NOTEXCEED ONE-HALFTHE HOIZONTALDIMENSIONS BETWEENTHE EDGES OF THEFOOTINGS.
"D"
"D"
S0.2
TYPICALCONCRETE DETAILS
WAP
16-297
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
AMP
DETAILS NOT TO SCALE
FOR PERMIT
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
FOR PERMIT01/29/19
01/29/19
874 East Sixth St.South Boston 02127
FOR PRICING04/01/19
04/03/19 FOR PERMIT
REISSUE (RAISE BLDG)03/19/20
REISSUE (RAISE BLDG)05/15/20
HEADER SCHEDULE AT INTERIOR BEARING WALLS
SPAN
0'-0" TO 3'-0"
SUPPORTING ROOF
HEADER
3-2x6
(UNLESS OTHERWISE NOTED ON DRAWINGS)
NOTE:
HEADERS AT FLOOR LEVELS ARE SIZED ASSUMING THAT THE OPENING ABOVEIS EQUAL TO OR LARGER THAN THE OPENING IN QUESTION.
3'-1" TO 5'-0"
5'-1" TO 8'-0"
8'-1" TO 10'-0"
JACK JAMB
2-2x6 1-2x6
2-2x6 1-2x6
2-2x6 1-2x6
2-2x6 1-2x6
3-2x10
3-2x12
3-2x12
JACK JAMB
2-2x6 1-2x6
2-2x6 1-2x6
2-2x6 2-2x6
2-2x6 2-2x6
HEADER
SUPPORTING ROOF + 1 FLOOR
3-2x8
3-1 3/4 X7 1/4" LVL
3-2x12
3-1 3/4 X14" LVL
JACK JAMB
2-2x6 1-2x6
2-2x6 3-2x6
3-2x6 3-2x6
3-2x6 3-2x6
HEADER
SUPPORTING ROOF + 2 FLOORS
3-2x8
3-1 3/4 X9 1/2" LVL
3-2x12
3-13/4 X18" LVL
HEADER SCHEDULE AT EXTERIOR BEARING WALLS
SPAN
0'-0" TO 3'-0"
SUPPORTING ROOF
HEADER
3-2x6
(UNLESS OTHERWISE NOTED ON DRAWINGS)
3'-1" TO 5'-0"
5'-1" TO 8'-0"
8'-1" TO 10'-0"
JACK JAMB
2-2x6 1-2x6
2-2x6 1-2x6
2-2x6 2-2x6
2-2x6 2-2x6
3-2x10
3-2x12
3-2x12
JACK JAMB
2-2x6 1-2x6
2-2x6 2-2x6
2-2x6 2-2x6
2-2x6 2-2x6
HEADER
SUPPORTING ROOF + 1 FLOOR
3-2x8
3-1 3/4 X7 1/4" LVL
3-2x12
3-1 3/4 X9 1/2" LVL
JACK JAMB
2-2x6 1-2x6
2-2x6 3-2x6
3-2x6 3-2x6
3-2x6 3-2x6
HEADER
SUPPORTING ROOF + 2 FLOORS
3-2x8
3-1 3/4 X9 1/2" LVL
3-2x12
3-13/4 X11 7/8 " LVL
LVL EQUIVALENTS(3) - 2x6 = (1) 1 3/4" X 7 1/4" LVL
(3) - 2x8 = (1) 1 3/4" X 7 1/4" LVL
(3) - 2x10 = (1) 1 3/4" X 9 1/2" LVL
(3) - 2x12 = (1) 1 3/4" X 11 7/8" LVL
(3) - 1 3/4" x 7 1/4" = (2) 1 3/4" X 9 1/2" LVL
(3) - 1 3/4" x 9 1/2" = (2) 1 3/4" X 11 7/8" LVL
(3) - 1 3/4" x 11 7/8" = (2) 1 3/4" X 14" LVL
SPAN LENGTH
1/3 SPAN 1/3 SPAN
1/3
DEP
TH
HOLE CUTTING NOTES:
1. SQUARE OR RECTANGULAR HOLES NOT PERMITTED.2. ROUND HOLES MAY BE DRILLED OR CUT WITH A HOLE SAW ANYWHERE WITHIN THE SHADED AREA.3. THE HORIZONTAL DISTANCE BETWEEN ADJACENT HOLES MUST BE AT LEAST TWO TIMES THE DIAMETER OF THE LARGER HOLE.4. DO NOT DRILL MORE THAN THREE HOLES IN ANY FOUR-FOOT LONG SECTION OF THE BEAM.5. THE MAXIMUM ROUND HOLE PERMITTED IS 2"∅.6. FOR LARGER HOLES CONTACT BOISE ENGINEERED WOOD PRODUCTS ENGINEERING.
ALLOWABLE HOLES IN BOISE VERSA-LAM BEAMS
HORIZONTALT&G DECKING
DOOR OPG
WINDOWOPG
PAIR SEISMIC HOLD DOWNANCHORS MATCHINGSIZE FOR SHEAR WALLDESIGNATION.SEE DETAIL AND SHEARWALL SCHEDULE
PANEL EDGE NAILINGSEE SHEAR WALL SCHEDULE
4'x8' SHEATHING PANEL,EXTERIOR FACE,STRUCTURAL I RATEDSHEAR WALL, 15/32" MIN,PROVIDE 5/8" IF INDICATEDIN ARCHITECTURAL DETAILS
2-2x6 AT END OFSHEAR WALL, MINIMUM
INTERMEDIATE NAILING6d @ 12" O.C.
SEISMIC HOLD DOWNANCHOR SEE DETAILAND SCHEDULE
CONCRETE FOUNDATION
FOUNDATION ANCHOR BOLTSOR EPOXY ANCHORS(SEE DETAIL FOR EPOXY)
(2) ROWS 16d SOLE PLATETO RIM BOARD
FLOOR JOISTS& RIM BOARD
2x6 BOTTOM PLATE
HEADERHEADER
2-2x6TOP PLATE
2x6 BLOCKING @ INTERMEDIATE
EDGES OFSHEATHING
PANEL (TYP)
2-2x6 SILL,FASTEN WITH 10d NAILS.2 ROWS @ 16" O.C.GEN'L NOTE:
STAGGER JOINTS IN TOP ANDBOTTOM PLATES MINIMUM 24"
SHEATHING FASTENERS@ 4" O.C. ALL AROUNDOPENINGS (TYP)
TYPICAL SHEAR WALL ELEVATION DETAIL
SDS SCREWS
HDU8-SDS2.5 SIMPSONHOLD DOWN ANCHOR
WITH 20 SDS 14"x212" SCREWS
78"∅ ANCHOR BOLT
112"
STAND-OFF "SO"
BUILT-UP 2-2x6 POSTWITH BLOCKING @ 24" O.C.
SIMPSONHOLD DOWN ANCHOR
WITH SDS SCREWS
ELEVATION VIEW PLAN VIEW
EPOXY ALTERNATE:DRILL HOLE MIN 7" EMBEDMENTAND GROUT IN BOLT WITH HILTI RE-500 + HAS(7" EMBEDMENT + 7" PROJECTION = 14" TOTAL LENGTH)
HEADER - SEE SCHEDULE
2x6 STUD BEARING WALL
CRIPPLE STUDS
2-2x6 TOP PLATE
OPENOPEN
2-2x6 SOLE PLATE(PRESSURE-TREATEDON CONCRETE)
HEADER - SEE SCHEDULE
JAMB STUD (TYP)
JACK STUD (TYP)
2x6 STUD BEARING WALL
CRIPPLE STUDS
2-2x6 TOP PLATE
2-2x6 SOLE PLATE(PRESSURE-TREATEDON CONCRETE)
CRIPPLE STUDS
2-2x6 SILL
JAMB STUD (TYP)
JACK STUD (TYP)
JACK STUD (TYP)
WINDOW OPG DOOR OPG
8" X 13" MAXHOLE SIZE
6"
6"
HOLE CUTTING NOTES:
1. A 112"∅ HOLE MAY BE CUT ANYWHERE OUTSIDE OF HATCHED AREAS.
2. FOR OTHER HOLES SEE THE HOLE DISTANCE CHART IN THE ALLJOIST SPECIFIERS GUIDE.3. OTHER LOCATIONS MUST BE APPROVED BY A BOISE-CASCADE REPRESENTATIVE AND APPROVED BY THE ENGINEER.
2'-0"
SPAN LENGTH
6"
6"6"
112"∅ MAX HOLE
AT CANTILEVERS
DISTANCE = MINIMUM 2X DIAMETER OF LARGEST HOLE
BCI I-JOIST 1178", 14" AND 16" DEPTHS
DISTANCE
6"∅ MAXHOLE SIZE
112"∅ MAX HOLE ANYWHERE
WITH 3" CLEARANCEFROM OTHER HOLES
2'-0"
8" X 13" MAXHOLE SIZE
6"
6"
HOLE CUTTING NOTES:
1. A 112"∅ HOLE MAY BE CUT ANYWHERE OUTSIDE OF HATCHED AREAS.
2. FOR OTHER HOLES SEE THE HOLE DISTANCE CHART IN THE ALLJOIST SPECIFIERS GUIDE.3. OTHER LOCATIONS MUST BE APPROVED BY A BOISE-CASCADE REPRESENTATIVE AND APPROVED BY THE ENGINEER.
2'-0"
SPAN LENGTH
6"
6"6"
112"∅ MAX HOLE
AT CANTILEVERS
DISTANCE = MINIMUM 2X DIAMETER OF LARGEST HOLE
BCI I-JOIST 1178", 14" AND 16" DEPTHS
DISTANCE
6"∅ MAXHOLE SIZE
112"∅ MAX HOLE ANYWHERE
WITH 3" CLEARANCEFROM OTHER HOLES
2'-0"
TYPICAL WOODFRAME DETAILS
1
S0.3
AMP
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
TYPICAL WOOD FRAMING OPENING LINTEL SCHEDULES
35 NO SCALELVL ALLOWABLE HOLESWALL FRAMING DETAILS
2 NO SCALE
BCI I-JOISTS ALLOWABLE LARGE RECTANGLE HOLES
NO SCALE
MULTIPLE MEMBER FASTENING SIDE & TOP LOADED LVL4 NO SCALE
NO SCALE
SEISMIC HOLD DOWN ANCHOR DETAIL7 NO SCALE
NO SCALE6TYPICAL SHEAR WALL ELEVATION DETAIL
AMP
FOR PERMIT
16-297
874 East Sixth St.South Boston 02127
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
01/29/19
01/29/19
FOR PRICING04/01/19
FOR PERMIT04/03/19
REISSUE (RAISE BLDG)03/19/20
REISSUE (RAISE BLDG)05/15/20
S0.4
AMP
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
4 NO SCALELVL ALLOWABLE HOLES
FOR PERMIT
1 TYPICAL WOOD FRAMING OPENING LINTEL SCHEDULES
NO SCALE
3TYPICAL WOOD FRAMING OPENING LINTEL SCHEDULES
NO SCALE
2TYPICAL WOOD FRAMING OPENING LINTEL SCHEDULES
NO SCALE
8 NO SCALELVL ALLOWABLE HOLES
5 TYPICAL WOOD FRAMING OPENING LINTEL SCHEDULES
NO SCALE
7 TYPICAL WOOD FRAMING OPENING LINTEL SCHEDULES
NO SCALE
6TYPICAL WOOD FRAMING OPENING LINTEL SCHEDULES
NO SCALE
16-297
874 East Sixth St.South Boston 02127
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
01/29/19
01/29/19
TYPICAL WOODFRAME DETAILS
AMP
FOR PRICING04/01/19
FOR PERMIT04/03/19
REISSUE (RAISE BLDG)
03/19/20
03/19/20
REISSUE (RAISE BLDG)05/15/20
5x5
918"
1'-2"
1'-0"
6'-6"
6'-6
"
1'-2
"
3'-3
"3'
-3"
B
12" x 12" x 1/2"STEEL PLATE
3
1'-458"
3'-3" 3'-3"
RE-BARS9-#6 EA. WAY
#5 @ 11" EA WAY
CLEAR DIM ELEVATOR PIT / HOISTWAY
1'-0
"
AS1.1
1'-412"
7'-514"
8'-1
1"
6'-6
"
3'-3
"
6'-6" 6'-6"
2
B
1'-0"
2
AS1.1
BA.6
3 3
1'-0" 1'-0" 1'-0"
ELEVATOR SHAFT DIMENSIONSARE SUBJECT TO CHANGE.CONTRACTOR SHALL VERIFYSHAFT DIMENSIONS OF THEAPPROVED ELEVATOR MODELAND PROVIDE PIT AND SHAFTWHICH MEET ELEVATORREQUIREMENTS.
10'-
8"
6'-6
"4'
-2"
3'-3
"3'
-3"
1'-0
"1'
-0"
CLEA
R D
IM E
LEVA
TOR
PIT
/ H
OIS
TWAY
9"
6'-6"
3'-3"3'-3"
3'-3
"3'
-3"
2'-718"
3'-3"
9'-1"
3'-3"
1'-0
"
SUMP PUMP PIT:1'-6" x 1'-6"x 1'-6" DEEP
REMOVE CONCFOUNDATION FORGARAGE DOOR
A: STL COL AT NEWGARAGE DOOR
B: STL COL AT COL LINE B
DELETE COL
1
5x5
1'-2"
1'-2
"
14" x 14"CONCRETE PIER
REINF. w/ 8 - #6VERTICAL
& #3 HOOPS@ 12"
1'-0" 1'-0" 1'-0"
1'-0
"
1'-0
"
3'-0"
#4's @ 12" EA WAY
CONCRETE SHALL BE4,00 PSI @ 28 DAYS.
ALL RE-BARS SHALL BEEPOXY COATED
2 x 8 PT SILLw/ 5 / 8 "
ANCHOR BOLT@ 4'-0" OC
2"
1'-6"
1'-6
"
SUMP PUMP PIT:1'-6" x 1'-6"x 1'-6" DEEP
1" STEEL GRATING
2'-0"
#6 @ 9" EW
CONTBENTONITE
WATERSTOPLAP
ALL SPLICES 16"
#6 @ 9" EW
3-#4
# 4 @ 12'# DOWELS EW
1'-3
"
3-#4
3'-0"B.O.F.
2'-9
"
5x5
5
B.9 C
9"
BASEPLATE8" x 15" x 3/4"
(4) 34" BOLTS w/ 6"EMBEDMENT
4"7"
LVL CANTELEVEREDBEAM ABOVE
CONC FOUNDATION
REMOVE CONCFOUNDATION FORGARAGE DOOR
LVL CANTELEVEREDBEAM ABOVE
WD COL WITHIN 2x6STUD WALL FORCANTELEVERED BEAM
6"
5x5
1
BASEPLATE8" x 15" x 3/4"
(4) 34" BOLTS w/ 6"EMBEDMENT
STEEL BEAM ABOVE
CONC FOUNDATION
6"
1.1
B
6"
6"
A: STL COL AT NEWGARAGE DOOR
B: STL COL AT COL LINE B
S0.5
AMP
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
2 1 / 2" = 1'-0"FOUNDATION @ ELEVATOR PIT
16-297
874 East Sixth St.South Boston 02127
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
01/29/19
CONC. FOUND.DETAILS
AMP
1 FOUNDATION @ ELEVATION OF STEEL COLUMN BASE PLATE1 1 /2"=1'-0"
3 1 / 2" = 1'-0"TYPICAL FOUNDATION WALL
4 CONCRETE PIER REINFORCEMENT TYPICAL & SIMILAR1 1 /2"=1'-0"
5 ELEVATOR SUMP PIT DETAIL1 / 2" = 1'-0"
FTG ELEVATIONS02/14/19
FOR PRICING04/01/19
04/01/19 FOR PERMIT
6 STEEL COLS ON FOUNDATION1 1 /2"=1'-0"
1
1 RAISE BLDG03/19/202 RAISE BLDG (17'-6")05/15/20
FOUNDATION / GROUND FLOOR PLAN
16'-4"18'-5"
PRE-CASTCONCRETELAGGINGRETAINING WALLSEE GEOTECHNICALCONSULT. DWGS.ES-1 & ES-2
AA3.1
35'-9"
A B C
11'-0"20'-3"
3'-3"
20'-
2"10
'-0"
24'-
2"10
'-8"
19'-
0"19
'-6"
15'-
0"
1
2
3
4
6
5
5'-612"
15'-0"
6'-6"
STAIRWAY 1
CANTILEVERABOVE
CANTILEVERABOVE
1/8" = 1'-0"
PROPERTY LINE
35'-9"
20'-3"15'-0"
STL COL
LOCATION
2/B
3/B
4/B
5/B
STEEL COLUMN SCHEDULE
COL SIZE DIMENSIONS
HSS 5x5x14"
S0.52
HSS 5x5x14" COMBINE WITH ELEV
HOISTWAY FOOTING.SEE DET 2/S0.5
(6) -5# EACH WAY
REINFORCING
COLUMN
HSS 5x5x14"
HSS 5x5x14" 6'-6"x6'-6"x1'-3"
HSS 5x5x14" 6'-6"x6'-6"x1'-3"
FOOTING
(9) #6 EACH WAY AT EA.COL. SEE DET 2/S0.5 &SECTION DET S1.1
(6) -5# EACH WAY
STL COL
A7.15
TYP
3'-0"
CONCFTG SEEDWG A3.1
1'-0"
LINE OFFOOTINGBELOW
12" DEPRESSEDSLAB AT STAIRWAY WALL
STEEL BEAMS ABOVESEE 1st FLOORFRAMING PLAN
1S1.1
HOLD-DOWN ANCHORSIMPSON HOLD DOWN HD5BW/ 58" ∅ ANCHOR BOLTSEE DETAIL 7/S0.3
BRACED WALL PARTITION- SEE ARCHITECTURAL DWGS
BWP
LEGEND
CONTRACTOR SHALL FIELD VERIFYEXISTING CONDITIONS AND MAKEFIELD DETERMINATION.
COMMENT
STL COL
1S1.1
STL COL
STEEL BEAMS ABOVESEE 1st FLOORFRAMING PLAN
AA3.1
PROPERTY LINE
PRO
PERT
Y LI
NE
PRO
PERT
Y LI
NE
PROPERTY LINE
PRO
PERT
Y LI
NE
PRO
PERT
Y LI
NE
125'
-0"
50'-0"
125'
-0"
10"
CUT OUT FOUNDATIONAND FRAME FOR NEWGARAGE DOOR
18'-
0"3'
-0"
3'-4
"9'
-2"
CONC INFILL @ OPG
4.1
5'-6
"
B CA B.9
6"
SLOPE FLOOR TODRAINS, SEE CIVILDWGS
CMU WALL TO HGT OFCONC FOUNDATION.CONCRETE FILL ALLCELLS, USE TRUSSTYPE H REINFORCING.
B.9
6"
DA3.3
DA3.3
STL COL
1.1
6"
5.9 STL COL
6"
3'-3" 11'-0"SONOTUBE FOOTINGSFOR STAIR LANDING
BA3.2
CA3.2
A3.2B
CA3.2
EA3.4
EA3.4
FOOTING FOR ENTRYROOF COLUMN (TYP)
CONC WALK ANDENTRY LANDING
1.1/B HSS 5x5x14"
5.9/B HSS 5x5x14"
4.1/B.9 HSS 5x5x14"
HSS 5x5x14"5.1/B.9
ON EXIST FOUNDATION
ON EXIST FOUNDATION
ON EXIST FOUNDATION
ON EXIST FOUNDATION
1A3.4
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
S0.56B
SIM
S0.56A
SIM
S0.56A
S0.56B
ELEVHOISTWAY
17'-6"
2
2
SECTION @ ELEVATOR PIT 3/4" =1'-0"
5'-9"
4'-6"
EXISTING (VERIFY): 8"CMU w/ #5@32"V 	GA WIRE LADDER@ 16"OC (TYP)
GARAGE
ELEVATOR PIT
ELEVATORHOISTWAY
HSS 5x5 x 1 / 4"COLUMN BEYOND
WWF#4 @ 15
#4 @ 12 EW
#6 @ 9"T&B EW
#4 @ 12 EW
WATER FOUND AT ELEV. 7'-0"WATER FOUND AT ELEV. 7'-0"
METALLICWATERPROOFING ALL
SIDES OF PIT
UNIT No. 1
CORRIDORNOTES:
CONCRETE SHALL BE 4,000 PSI @ 28 DAYSALL RE-BARS SHALL BE EPOXY COATED.
ALL CONCRETE WORK SHALL BEACCOMPLISHED IN DRY CONDITIONS.CONTRACTOR SHALL PUMP WATER ASREQUIRED, IN ACCORDANCE WITH ALLREGULATIONS.
NOTE:STEP FOOTINGS INACCORDANCE WITHSTRUCTURAL ENG.RECOMMENDATIONS
NEAR ELEVATOR,BOTTOM OF WALLFTG TO ALIGNWITH ELEVATORPIT FTG
6'-6" x 6'-6"x1'-3"FOOTING & PEDESTALFOR HSS 5x5 COL. BEYONDSHALL BE AT SAMEELEVATIONAS ELEV. PIT FOOTING
PRO
PERT
Y LI
NE
A
T.O.FOUNDATIONEL. 18'-3"
ORIG. BASEMENTAVG EL. 10'-6"
1'-0"1'-0"
3'-3"
3'-0"
B.O. FTGVARIES
1'-0"
1'-0" 1'-0"
1'-0
"M
IN
LINE OF SUMP PITBEYOND.SEE DWG. S0.5
BOND BEAM 3 1 / 2" x 5"2 ANG. BACK TO BACK
1'-2" x 1'-2"CONC. PIER BEYOND
B
B.O. PIT FOOTINGEL. 4'-6"
1'-0"
5'-0
"
1'-0"
15'-0"
4'-612"
1'-3
"
1
2-HR FLOOR ASSEMBLY AT1st FLOOR TO PROVIDECONTINUOUS 2-HR RATEDPASSAGE FROM STAIR 1 TOFRONT DOOR EXITDISCHARGE
GROUND FLOOREL. 17'-6"GROUND FLOOR
EL. 17'-6"
1st FLOORT.O. PLWDEL. 27'-2"
2A0.3
WF STEEL BEAMS VARYSEE FRAMING PLANS
REMOVE EXISTFLOOR STRUCTURE
SS ELEVATOR DOOR FRAME
ELEVATOR DOOR
EXTEND EXIST COLPIER UP TO NEW EL.
NEW T.O. COLPIER EL. 16'-9"
9"
EXIST T.O.COL PIER
REMOVE EXIST S.O.G.
REMOVE EXIST CMU ASREQUIRED, PREP NEWDOOR OPG
INFILL ORIGINAL OPG W/CONC, REINFORCING AS
TYPICALLY INDICATED
ELEVATOR FRAME
ABANDON ORIGINALELEVATOR PIT
REMOVE EXISTFLOOR STRUCTURE
ADD ELEVATOR DOOR
1'-3
"8"
RENFORCED CONCPIT FLOOR ONCOMPACTED FILL.PIN TO
ELEVATOR DOOR
REMOVE EXIST S.O.G.
7'-514"
ELEV PIT EL 12'-6"
1st FLOORT.O. PLWDEL. 27'-2"
4A0.35
A0.3
3AA0.3
LINE OF SUMP PITBEYOND.SEE DWG. S0.5
REMOVE PART OF EXISTCMU WALL AS REQUIREDFOR NEW DOOR OPG.
WATER PROOFINGWATER PROOFING
9'-8
"5'
-0"
7
W2
APPROVEDWINDOWSYSTEM
56
8" PIN: #5 16" LONG @16" O.C.. EMBED 8"
CORRIDOR 2
AMP AMP
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
S1.1
FTG ELEVATIONS02/14/19
FOUNDATION PLAN& ELEVATOR PIT
FOR PRICING04/01/19
FOR PERMIT04/03/19
04/03/19
RAISE BLDG1 03/19/20RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
FIRST FLOOR FRAMING PLAN
125'
-0"
AA3.1A B C
20'-
2"
10'-
0"24
'-2"
10'-
8"19
'-0"
19'-
6"15
'-0"
1
2
3
4
6
5
5'-612"
35'-9"
6'-412"
1/8" = 1'-0"
W12
x 2
2W
12 x
65
B CA
20'-3"15'-0"
PROPERTY LINE (TYP)
S0.37
TYP
HOLD-DOWN ANCHORSIMPSON HOLD DOWN HD5BW/ 58" ∅ ANCHOR BOLTSEE DETAIL 7/S0.3
BRACED WALL PARTITION- SEE ARCHITECTURAL DWGS
BWP
LEGEND
CONTRACTOR SHALL FIELD VERIFYEXISTING CONDITIONS AND MAKEFIELD DETERMINATION.
(3) 1 3/4" X 11 7/8" LVL's
W24
x 6
8
STL COL DN,WD POST UP
STL COL DN,WD POST UP
WD POST UP
STL COL DN,WD POST UP
STL COL DN,WD POST UP
BALC 2x10'S@ 16" OC
AA3.1
W24
x 1
04W
16 x
50
BALC
FRAMINGRADIUS60'-0"
CANTILEVERABOVE AT2nd FLOOR
FRAMINGRADIUS20'-3"
FOUNDATIONWALL BELOW(TYP)
CANTILEVEREDWING (TYP)
CANTILEVEREDWING (TYP)
TYPICAL FRAMING NOTES:
1. EXTERIOR OPGS (DOOR, WINDOWS) ARE FULL HEIGHT. ALLHEADERS SHALL BE FLUSH-FRAMED WITH FLOOR OR ROOF ABOVE.SEE ARCH DWGS FOR LOCATIONS.
2. LVL BEAMS ARE FLUSH-FRAMED EXCEPT WHERE NOTED(CANTILEVERS).
3. PROVIDE RADIUSED LVL's AT EDGE OF ALL CANTILEVERED WINGS.MATCH FRAMING RADIUS INDICATED ON PLAN.
4. PROVIDE HURRICANE TIES AT EACH ROOF RAFTER.
5. FLOOR DECKING FLOORS 1-3 : 3/4" PLYWOOD
6. DECKING AT ROOF: 5/8" PLYWOOD.
7. STAIRWAY ENCLOSURE SHALL BE CONSTRUCTED AS A FIREBARRIER, WITH CONTINUOUS FIRE RATING FROM TOP OF FLOORDECKING TO UNDERSIDE OF FLOOR OR ROOF DECKING ABOVE. ATFLOOR JOISTS, PROVIDE JOIST HANGERS ON LEDGER. GWB SHALLEXTEND UP BETWEEN LEDGER AND STAIRWAY ENCLOSURE STUDS.
CONCRETE FOUNDATION
WOOD FRAME BEARING WALL BELOW
LANDING2x12's
LANDING2x12's
STAIRWAY 1
SECOND FLOOR FRAMING PLAN
20'-
2"
1
AA3.1B CA
10'-
8"
2
3
19'-
0"
4
6
5
19'-
6"15
'-0"
10'-
0"
BALC
1/8" = 1'-0"
POSTUP & DN
HEADER
FLUSH TOP
HEADERHEADER
B CA
POST UP& DN
POST UP & DN
POST UP& DN
POSTUP & DN
PROPERTY LINE (TYP)
35'-9" 11'-0"
20'-3"15'-0"
3'-3"
LANDING2x12's
POST UP & DN
POST UP& DN
FRAMERADIUS23'-2"
DROPPED BEAM(3) 1 34" X 14" LVL's
2x10's @ BALCONY
(2) 134" x 14" LVL's CANTILEVERED
POST UP & DN
POST UP & DN
BEARING WALLBELOW (TYP)
DROPPED BEAM(3) 13
4" X 14" LVL's
FRAMINGRADIUS20'-3"
134" x 14" LVL's @ 16" O.C.
CANTILEVERED
CANTILEVERED WING (TYP)
AA3.1
6'-3
"
CANTILEVEREDWING (TYP)
LANDING2x12's
FRAMINGRADIUS60'-0"
(4) 134" x 14" LVL's
CANTILEVERED
M
M
M
M
FLOOR PLAN ON TOP OF FLOOR FRAMING
14" TJI 110 @ 16" O.C.
14" TJI 110 @ 16" O.C.
14" TJI 110 @ 16" O.C.
14" TJI 110 @ 16" O.C.
14" TJI 210 @ 16" O.C.
DROPPED BEAM(3) 13
4" X 14" LVL's
14" TJI 210 @ 16" O.C.
134" x 14" LVL's @ 16" O.C.
CANTILEVERED
CANTILEVEREDWING (TYP)
14" TJI 110 @ 16" O.C.
2x10 @ 16" O.C.
14" TJI 110 @ 16" O.C.
134" X 14" LVL'S @ 16" O.C.
CUT TO FIT or 14" TJI 210@ 16" O.C.
134" x 14" LVL's @ 16" O.C.
CANTILEVERED 134" x 14" LVL's @ 16" O.C.
CANTILEVERED
14" TJI 110 @ 16" O.C.
(3) - 134" x 14" LVL'S
(3) - 134" x 14" LVL'S
(3) - 134" x 14" LVL'S
(2) - 134" x 14" LVL'S
(4) - 134" x 14" LVL'S
14" TJI 210 @ 16" O.C.
134" x 14" LVL's @ 16" O.C.
CANTILEVERED
CURVED EDGEBEAM (TYP)
CURVED EDGEBEAM (TYP)
STEEL BEAM HEADER OVERGARAGE DOOR BELOW
BEARING WALL BELOW
HEADER
5'-6
"
4.1
134" x 91
2" LVL's @ 12" O.C.W21
x 5
7
(4) 134" x 14" LVL's
CANTILEVERED
STL
COL
DN
WD POST UPWD POST UP
(2) 134" x 14" LVL's
HEADERS AT OPGS (TYP)
STAIRWAY
2
DA3.3
7'-7
"7'
-11"
4.1
5'-6
"
B.9
6"
B.9
35'-9"
20'-3"15'-0" 6"
B.9
STL COL DN, WD POST UP
5.9
6"
1.1
6"
2x6 BEARINGWALL BELOW
(TYP)
DA3.3
DA3.3
1.1
5.9
24'-
2"6"
3'-3" 11'-0"3'-3" 11'-0"
B.9
6"
4'-7
"
(2) 134" X 21" LVL @ 16" O.C.
3'-8"
10'-1012"
3'-8"
10'-1012"BATHROOM FIXTURES,
COORDINATE FRAMING TOAVOID PLUMBING
WDPOST UP
BEARING WALL UP
2x10 @ 16" O.C. (-12")
(3) 134" X 14" LVL
STL COL DN,WD POST UP
HEADER
BALC 2x10'S@ 16" OC
LVL HEADERS AT ALLOPGS FLUSH TOP
M MOMENT CONNECTION
DA3.3
HEADER
FLUSH TOP
6"
POSTUP
POSTDN
35'-9"3'-3"
11'-0"20'-3"15'-0" 6"
2x8 @ 16" O.C. FLUSH BOTTOM
(3) 2x12
1A3.4
1A3.4
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
1S1.1
1S1.1
(3) 134" X 91
2" LVL'S
7'-7
"5'
-8"
POST UP & DN
13'-
10"
5'-8
"
ELEVHOISTWAY
ELEVHOISTWAY
STAIRWAY 1
2
AMP AMP
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
1st & 2nd FLOORFRAMING PLANS
S1.2
FOR PRICING04/01/19
FOR PERMIT04/03/19
04/03/19
RAISE BLDG1 03/19/20RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202
THIRD FLOOR FRAMING PLAN1/8" = 1'-0"
ROOF FRAMING PLAN1/8" = 1'-0"
STAIRWAY 1
20'-
2"
1
AA3.1B CA
10'-
8"
2
3
24'-
2"19
'-0"
4
6
5
19'-
6"10
'-0"
BALC
POSTUP & DN
HEADER
HEADERS
POST UP& DN
POST UP& DN
POST UP& DN
POSTUP & DN
PROPERTY LINE (TYP)
35'-9" 11'-0"
20'-3"15'-0"
3'-3"
LANDING2x12's
POST UP& DN
FRAMINGRADIUS60'-0"
FRAMERADIUS23'-2"
DROPPED BEAM(3) 13
4" X 14" LVL's
STAIRWAY 1
20'-
2"
1
AA3.1B CA
10'-
8"
2
3
24'-
8"19
'-0"
4
6
5
19'-
6"10
'-0"
FRAMINGRADIUS20'-3"
POST DN
HEADER
HEADERS
POST DN
POST DN
POST DN
POST DN
PROPERTY LINE (TYP)
35'-9" 11'-0"
20'-3"15'-0"
3'-3"
LANDING2x12's
POST DNFRAMINGRADIUS60'-0"
FRAMERADIUS23'-2"
DROPPED BEAM(3) 1 34" X 14" LVL's
CANTILEVEREDWING (TYP)
CANTILEVEREDWING (TYP)
DROPPED BEAM(3) 13
4" X 14" LVL's
DROPPED BEAM(3) 13
4" X 14" LVL's
POST DN
HEADERHEADER
DROPPED BEAM(3) 13
4" X 14" LVL's
2x10's @ BALCONY
POST UP & DN
POST UP & DN
POST UP & DNPOST DN
CANTILEVERED WING (TYP)
134" x 14" LVL's @ 16" O.C.
CANTILEVERED
FRAMINGRADIUS20'-3"
DROPPED BEAM(3) 13
4" X 14" LVL's
134" x 14" LVL's @ 16" O.C.
CANTILEVERED
CANTILEVERED WING (TYP)
POSTDN
POSTUP & DN
POST DN POST UP& DN
ROOFTOP CONDENSERABOVE (TYPICAL)
AA3.1
AA3.1
POST DNPOST UP & DN
DROPPED BEAM(3) 13
4" X 14" LVL's
CANTILEVEREDWING (TYP)
CANTILEVEREDWING (TYP)
LANDING2x12's
LANDING2x12's
(2) 134" x 14" LVL's CANTILEVERED
14" TJI 210 @ 16" O.C.
14" TJI 110 @ 16" O.C.
14" TJI 110 @ 16" O.C.
14" TJI 110 @ 16" O.C.
14" TJI 110 @ 16" O.C.
14" TJI 210 @ 16" O.C.
14" TJI 210 @ 16" O.C.
134" x 14" LVL's @ 16" O.C.
CANTILEVERED
134" x 14" LVL's @ 16" O.C.
CANTILEVERED
14" TJI 110 @ 16" O.C.
14" TJI 110 @ 16" O.C.
14" TJI 110 @ 16" O.C.
14" TJI 110 @ 16" O.C.
14" TJI 210 @ 16" O.C.
134" x 14" LVL's @ 16" O.C.
CANTILEVERED
134" x 14" LVL's @ 16" O.C.
CANTILEVERED
DROPPED BEAM(3) 13
4" X 14" LVL's
(3) - 134" x 14" LVL'S
(3) - 134" x 14" LVL'S
(2) - 134" x 14" LVL'S
(4) - 134" x 14" LVL'S
(3) - 134" x 14" LVL'S
(3) - 134" x 14" LVL'S
(3) - 134" x 14" LVL'S
(3) - 134" x 14" LVL'S
3'-278"
ELEVATOR HOISTWAY:-HOIST BEAM W8 x 24-2-HR CONC SLAB /
COMPOSITE DECK ATHOISTWAY ROOF ROOF /MACHINE ROOM FLOOR
4.1
5'-6
"
4.1
5'-6
"
B CA B.9B CA B.9
35'-9"
20'-3"15'-0" 6"
35'-9"
20'-3"15'-0" 6"
15'-
0"
1.1
5.9
6"
15'-
0"
1.1
5.9
6"
6"
3'-3" 11'-0"3'-3" 11'-0"
B.9B.9
6" 6"
DA3.3
DA3.3
DA3.3
DA3.3
HEADER
FLUSH TOP
POST UP& DN
POST UP& DN
8'-0"
7'-4"
BALC 2x10'S@ 16" OC
POST DN
HEADER
FLUSH TOP
HEADER
FLUSH TOP
HEADER
FLUSH TOP
STAIRWAY
2
1GENERAL REVISION:RAISE BUILDING DUETO FLOOD ZONE
5'-8
"
POSTDN
7'-7
"5'
-8"
6'-3
"
13'-
10"
5'-8
"
POST DN
ELEVHOISTWAY
ELEVHOISTWAY
2NO REVISION,RE-ISSUE ONLY
AA3.1
2
3
4
6
5
1
BA
STAIR WAY 1
ELEV.MACH.ROOM
HIGH ROOF FRAMING PLAN1/8" = 1'-0"
AA3.1
ROOF JOISTS2x8 @ 16" O.C
ROOF JOISTS2x8 @ 16" O.C
5/8" PLYWD DECK
2-HR 612" CONC SLAB
/ COMPOSITE STEELDECK AT HOISTWAYROOF ROOF /MACHINE ROOMFLOOR
BA
4.1
5.9
1.1
DA3.3
DA3.3
FRAME ASREQUIRED FORHOISTWAY ANDMACHINE ROOMVENTS
HOLD-DOWN ANCHORSIMPSON HOLD DOWN HD5BW/ 58" ∅ ANCHOR BOLTSEE DETAIL 7/S0.3
BRACED WALL PARTITION- SEE ARCHITECTURAL DWGS
BWP
LEGEND
CONTRACTOR SHALL FIELD VERIFYEXISTING CONDITIONS AND MAKEFIELD DETERMINATION.
TYPICAL FRAMING NOTES:
1. EXTERIOR OPGS (DOOR, WINDOWS) ARE FULL HEIGHT. ALLHEADERS SHALL BE FLUSH-FRAMED WITH FLOOR OR ROOF ABOVE.SEE ARCH DWGS FOR LOCATIONS.
2. LVL BEAMS ARE FLUSH-FRAMED EXCEPT WHERE NOTED(CANTILEVERS).
3. PROVIDE RADIUSED LVL's AT EDGE OF ALL CANTILEVERED WINGS.MATCH FRAMING RADIUS INDICATED ON PLAN.
4. PROVIDE HURRICANE TIES AT EACH ROOF RAFTER.
5. FLOOR DECKING FLOORS 1-3 : 3/4" PLYWOOD
6. DECKING AT ROOF: 5/8" PLYWOOD.
7. STAIRWAY ENCLOSURE SHALL BE CONSTRUCTED AS A FIREBARRIER, WITH CONTINUOUS FIRE RATING FROM TOP OF FLOORDECKING TO UNDERSIDE OF FLOOR OR ROOF DECKING ABOVE. ATFLOOR JOISTS, PROVIDE JOIST HANGERS ON LEDGER. GWB SHALLEXTEND UP BETWEEN LEDGER AND STAIRWAY ENCLOSURE STUDS.
CONCRETE FOUNDATION
WOOD FRAME BEARING WALL BELOW
FLOOR PLAN ON TOP OF FLOOR FRAMING
M MOMENT CONNECTION
AMP AMP
16-297
874 East Sixth St.South Boston 02127
NEW MULTI-FAMILY DWELLING
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
This document is recorded on or can be transmitted onelectronic media It is therefore subject to undetectablealteration or erasure, intentional or unintentional, due tocauses including, without limitation transmission,conversion, translation, media degradation, software error,human error or alteration. Accordingly, Pisani + AssociatesArchitects shall not be held liable for claims, losses, damages,or costs arising out of any such alterations or unauthorizedre-use or modification of this document or any part thereof.
ARCHITECT'S PROJECT NO. 16-297
OWNER
SURVEYOR
874 EAST 6TH STREET LLC.874 EAST 6TH STREETSOUTH BOSTON, MA 02127
BOSTON SURVEY, INC.UNIT C-4 SHIPWAYS PLACECHARLESTOWN, MA 02129
OWNER'S CONSULTANTS
GEO-TECHNICAL ENGINEER
STRUCTURAL ENGINEEREVAN HANKIN P.E.202 NEHOIDEN ROADNEWTON, MA 02468
CIVIL ENGINEERCIVIL ENGINEERINGCONSULTANTS3 OAK STREETPEABODY, MA 01960
GEOTECHNICALCONSULTANTS, INC.201 BOSTON POST ROAD WESTMARLBOROUGH MA 01752
MECHANICAL/ ENGINEERZADE ASSOCIATES, LLC140 BEACH STREETBOSTON MA 02111
FIRE PROTECTION ENGINEERPROMETHEUSLIFE SAFETY17 MILL RUN RD.BOXFORD MA
S1.3
3rd FLOOR & ROOFFRAMING PLANS
FOR PRICING04/01/19
FOR PERMIT04/03/19
04/03/19
1 RAISE BLDG03/19/20RAISE GR FLR TOEL 17'-6" / RE-ISSUE05/15/202