36
Haier Commercial Air Condition ADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice. Web: Http://www.haier.com Submittal Data Sheet Four-way Cassette AB052MCERA • 700mm x 700mm panel design for installation in limited space • Pre-set fresh air inlet to improve indoor air quality • Built-in high lift drain pump • Quiet operation FEATURES & BENEFITS

Four-way Cassette

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Four-way CassetteAB052MCERA

• 700mm x 700mm panel design for installation in limited space

• Pre-set fresh air inlet to improve indoor air quality

• Built-in high lift drain pump

• Quiet operation

FEATURES & BENEFITS

Page 2: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Indoor unit name:

Indoor unit model:

Type:

Rated cooling capacity(kW):

Sensible capacity(kW):

Cooling input power(kW):

Power supply(V/Hz/Ph):

Power supply connections:

Min. circuit Amps MCA (A):

Dimensions(H×W×D)(mm):

Panel(H×W×D)(mm):

Net weight(kg):

Panel weight(kg):

Airflow rate (H/M/L)(m3/h):

Moisture removal(m3/h):

Gas pipe connection(mm):

Liquid pipe connection(mm):

Condensate connection(mm):

Sound pressure(H/M/L)(dBA):

Sound power level(H/M/L)(dBA):

Four-way Cassette

AB052MCERA

Ceiling Cassette

1.5

1.1

0.08

220-230/50/60/1

L,N, Ground

0.5

1.6

260×570×570

60×700×700

17

2.8

1.7

0.08

650/540/430

Φ9.52

Φ6.35

Φ32

31/29/28

45/43/42

0/0

Indoor(°C DB/WB):27/19Ambient(°C DB/WB):35/24

Indoor(°C DB/WB):20/14.5Ambient(°C DB/WB):7/6

Rated heating capacity(kW):

Heating input power(kW):

Rated cooling conditions:

Rated heating conditions:

Rated piping length (m):

Rated height separation(m):

PERFORMANCE

INDOOR UNIT DETAILS

Ext. static pressure(Rated/Max)(Pa):

Max. fuse Amps MFA (A):

Page 3: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

DIMENSIONAL DRAWING

SN Part name1 Connection port of gas pipe2 Connection of liquid pipe

3 Wiring connection port of motor/pumping motor

4 Connect drain pipe5 Inlet grille6 Outlet grille7 Drain hose (accessory)

(Installed at high place)Less than 2700 to the w

all

Connect fresh air inlet accessory Φ100 (direct installation)

4-M3.2reserved hole

Greater than 1000 resreved space

210

6060 580

100

100

Less than 40

175

650 (celing open)570 (indoor units)

535 (Gap betw

wn supending rod)

Indoor units 570Less than100Decoration board 700

Pipe connection diagram

Connection drain pipe

700 (Decoration board)

60

285180175140

6060

350350 210

Suspendingbolt

4-M8-M10

170 176

195580

Adjustable (0-360)

Raise to less than 750

25

200

30

55

275 210

Page 4: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Four-way CassetteAB072MCERA

• 700mm x 700mm panel design for installation in limited space

• Pre-set fresh air inlet to improve indoor air quality

• Built-in high lift drain pump

• Quiet operation

FEATURES & BENEFITS

Page 5: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Indoor unit name:

Indoor unit model:

Type:

Rated cooling capacity(kW):

Sensible capacity(kW):

Cooling input power(kW):

Power supply(V/Hz/Ph):

Power supply connections:

Min. circuit Amps MCA (A):

Dimensions(H×W×D)(mm):

Panel(H×W×D)(mm):

Net weight(kg):

Panel weight(kg):

Airflow rate (H/M/L)(m3/h):

Moisture removal(m3/h):

Gas pipe connection(mm):

Liquid pipe connection(mm):

Condensate connection(mm):

Sound pressure(H/M/L)(dBA):

Sound power level(H/M/L)(dBA):

Four-way Cassette

AB072MCERA

Ceiling Cassette

2.2

1.8

0.08

220-230/50/60/1

L,N, Ground

0.5

1.6

260×570×570

60×700×700

17

2.8

2.5

0.08

700/590/480

Φ9.52

Φ6.35

Φ32

32/30/29

46/44/43

0/0

Indoor(°C DB/WB):27/19Ambient(°C DB/WB):35/24

Indoor(°C DB/WB):20/14.5Ambient(°C DB/WB):7/6

Rated heating capacity(kW):

Heating input power(kW):

Rated cooling conditions:

Rated heating conditions:

Rated piping length (m):

Rated height separation(m):

PERFORMANCE

INDOOR UNIT DETAILS

Ext. static pressure(Rated/Max)(Pa):

Max. fuse Amps MFA (A):

Page 6: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

DIMENSIONAL DRAWING

SN Part name1 Connection port of gas pipe2 Connection of liquid pipe

3 Wiring connection port of motor/pumping motor

4 Connect drain pipe5 Inlet grille6 Outlet grille7 Drain hose (accessory)

(Installed at high place)Less than 2700 to the w

all

Connect fresh air inlet accessory Φ100 (direct installation)

4-M3.2reserved hole

Greater than 1000 resreved space

210

6060 580

100

100

Less than 40

175

650 (celing open)570 (indoor units)

535 (Gap betw

wn supending rod)

Indoor units 570Less than100Decoration board 700

Pipe connection diagram

Connection drain pipe

700 (Decoration board)

60

285180175140

6060

350350 210

Suspendingbolt

4-M8-M10

170 176

195580

Adjustable (0-360)

Raise to less than 750

25

200

30

55

275 210

Page 7: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Four-way CassetteAB092MCERA

• 700mm x 700mm panel design for installation in limited space

• Pre-set fresh air inlet to improve indoor air quality

• Built-in high lift drain pump

• Quiet operation

FEATURES & BENEFITS

Page 8: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Indoor unit name:

Indoor unit model:

Type:

Rated cooling capacity(kW):

Sensible capacity(kW):

Cooling input power(kW):

Power supply(V/Hz/Ph):

Power supply connections:

Min. circuit Amps MCA (A):

Dimensions(H×W×D)(mm):

Panel(H×W×D)(mm):

Net weight(kg):

Panel weight(kg):

Airflow rate (H/M/L)(m3/h):

Moisture removal(m3/h):

Gas pipe connection(mm):

Liquid pipe connection(mm):

Condensate connection(mm):

Sound pressure(H/M/L)(dBA):

Sound power level(H/M/L)(dBA):

Four-way Cassette

AB092MCERA

Ceiling Cassette

2.8

2.1

0.08

220-230/50/60/1

L,N, Ground

0.5

1.6

260×570×570

60×700×700

17

2.8

3.2

0.08

700/590/480

Φ9.52

Φ6.35

Φ32

32/30/29

46/44/43

0/0

Indoor(°C DB/WB):27/19Ambient(°C DB/WB):35/24

Indoor(°C DB/WB):20/14.5Ambient(°C DB/WB):7/6

Rated heating capacity(kW):

Heating input power(kW):

Rated cooling conditions:

Rated heating conditions:

Rated piping length (m):

Rated height separation(m):

PERFORMANCE

INDOOR UNIT DETAILS

Ext. static pressure(Rated/Max)(Pa):

Max. fuse Amps MFA (A):

Page 9: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

DIMENSIONAL DRAWING

SN Part name1 Connection port of gas pipe2 Connection of liquid pipe

3 Wiring connection port of motor/pumping motor

4 Connect drain pipe5 Inlet grille6 Outlet grille7 Drain hose (accessory)

(Installed at high place)Less than 2700 to the w

all

Connect fresh air inlet accessory Φ100 (direct installation)

4-M3.2reserved hole

Greater than 1000 resreved space

210

6060 580

100

100

Less than 40

175

650 (celing open)570 (indoor units)

535 (Gap betw

wn supending rod)

Indoor units 570Less than100Decoration board 700

Pipe connection diagram

Connection drain pipe

700 (Decoration board)

60

285180175140

6060

350350 210

Suspendingbolt

4-M8-M10

170 176

195580

Adjustable (0-360)

Raise to less than 750

25

200

30

55

275 210

Page 10: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Four-way CassetteAB122MCERA

• 700mm x 700mm panel design for installation in limited space

• Pre-set fresh air inlet to improve indoor air quality

• Built-in high lift drain pump

• Quiet operation

FEATURES & BENEFITS

Page 11: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Indoor unit name:

Indoor unit model:

Type:

Rated cooling capacity(kW):

Sensible capacity(kW):

Cooling input power(kW):

Power supply(V/Hz/Ph):

Power supply connections:

Min. circuit Amps MCA (A):

Dimensions(H×W×D)(mm):

Panel(H×W×D)(mm):

Net weight(kg):

Panel weight(kg):

Airflow rate (H/M/L)(m3/h):

Moisture removal(m3/h):

Gas pipe connection(mm):

Liquid pipe connection(mm):

Condensate connection(mm):

Sound pressure(H/M/L)(dBA):

Sound power level(H/M/L)(dBA):

Four-way Cassette

AB122MCERA

Ceiling Cassette

3.6

2.6

0.08

220-230/50/60/1

L,N, Ground

0.5

1.6

260×570×570

60×700×700

19

2.8

4

0.08

700/590/480

Φ12.7

Φ6.35

Φ32

32/30/29

46/44/43

0/0

Indoor(°C DB/WB):27/19Ambient(°C DB/WB):35/24

Indoor(°C DB/WB):20/14.5Ambient(°C DB/WB):7/6

Rated heating capacity(kW):

Heating input power(kW):

Rated cooling conditions:

Rated heating conditions:

Rated piping length (m):

Rated height separation(m):

PERFORMANCE

INDOOR UNIT DETAILS

Ext. static pressure(Rated/Max)(Pa):

Max. fuse Amps MFA (A):

Page 12: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

DIMENSIONAL DRAWING

SN Part name1 Connection port of gas pipe2 Connection of liquid pipe

3 Wiring connection port of motor/pumping motor

4 Connect drain pipe5 Inlet grille6 Outlet grille7 Drain hose (accessory)

(Installed at high place)Less than 2700 to the w

all

Connect fresh air inlet accessory Φ100 (direct installation)

4-M3.2reserved hole

Greater than 1000 resreved space

210

6060 580

100

100

Less than 40

175

650 (celing open)570 (indoor units)

535 (Gap betw

wn supending rod)

Indoor units 570Less than100Decoration board 700

Pipe connection diagram

Connection drain pipe

700 (Decoration board)

60

285180175140

6060

350350 210

Suspendingbolt

4-M8-M10

170 176

195580

Adjustable (0-360)

Raise to less than 750

25

200

30

55

275 210

Page 13: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Four-way CassetteAB162MCERA

• 700mm x 700mm panel design for installation in limited space

• Pre-set fresh air inlet to improve indoor air quality

• Built-in high lift drain pump

• Quiet operation

FEATURES & BENEFITS

Page 14: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Indoor unit name:

Indoor unit model:

Type:

Rated cooling capacity(kW):

Sensible capacity(kW):

Cooling input power(kW):

Power supply(V/Hz/Ph):

Power supply connections:

Min. circuit Amps MCA (A):

Dimensions(H×W×D)(mm):

Panel(H×W×D)(mm):

Net weight(kg):

Panel weight(kg):

Airflow rate (H/M/L)(m3/h):

Moisture removal(m3/h):

Gas pipe connection(mm):

Liquid pipe connection(mm):

Condensate connection(mm):

Sound pressure(H/M/L)(dBA):

Sound power level(H/M/L)(dBA):

Four-way Cassette

AB162MCERA

Ceiling Cassette

4.5

3.2

0.08

220-230/50/60/1

L,N, Ground

0.5

1.6

260×570×570

60×700×700

19

2.8

5

0.08

700/590/480

Φ12.7

Φ6.35

Φ32

33/30/29

47/44/43

0/0

Indoor(°C DB/WB):27/19Ambient(°C DB/WB):35/24

Indoor(°C DB/WB):20/14.5Ambient(°C DB/WB):7/6

Rated heating capacity(kW):

Heating input power(kW):

Rated cooling conditions:

Rated heating conditions:

Rated piping length (m):

Rated height separation(m):

PERFORMANCE

INDOOR UNIT DETAILS

Ext. static pressure(Rated/Max)(Pa):

Max. fuse Amps MFA (A):

Page 15: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

DIMENSIONAL DRAWING

SN Part name1 Connection port of gas pipe2 Connection of liquid pipe

3 Wiring connection port of motor/pumping motor

4 Connect drain pipe5 Inlet grille6 Outlet grille7 Drain hose (accessory)

(Installed at high place)Less than 2700 to the w

all

Connect fresh air inlet accessory Φ100 (direct installation)

4-M3.2reserved hole

Greater than 1000 resreved space

210

6060 580

100

100

Less than 40

175

650 (celing open)570 (indoor units)

535 (Gap betw

wn supending rod)

Indoor units 570Less than100Decoration board 700

Pipe connection diagram

Connection drain pipe

700 (Decoration board)

60

285180175140

6060

350350 210

Suspendingbolt

4-M8-M10

170 176

195580

Adjustable (0-360)

Raise to less than 750

25

200

30

55

275 210

Page 16: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Four-way CassetteAB182MCERA(C)

• 700mm x 700mm panel design for installation in limited space

• Pre-set fresh air inlet to improve indoor air quality

• Built-in high lift drain pump

• Quiet operation

FEATURES & BENEFITS

Page 17: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Indoor unit name:

Indoor unit model:

Type:

Rated cooling capacity(kW):

Sensible capacity(kW):

Cooling input power(kW):

Power supply(V/Hz/Ph):

Power supply connections:

Min. circuit Amps MCA (A):

Dimensions(H×W×D)(mm):

Panel(H×W×D)(mm):

Net weight(kg):

Panel weight(kg):

Airflow rate (H/M/L)(m3/h):

Moisture removal(m3/h):

Gas pipe connection(mm):

Liquid pipe connection(mm):

Condensate connection(mm):

Sound pressure(H/M/L)(dBA):

Sound power level(H/M/L)(dBA):

Four-way Cassette

AB182MCERA(C)

Ceiling Cassette

5.6

3.8

0.08

220-230/50/60/1

L,N, Ground

0.5

1.6

260×570×570

60×700×700

19

2.8

6.3

0.08

700/590/480

Φ12.7

Φ6.35

Φ32

33/30/29

47/44/43

0/0

Indoor(°C DB/WB):27/19Ambient(°C DB/WB):35/24

Indoor(°C DB/WB):20/14.5Ambient(°C DB/WB):7/6

Rated heating capacity(kW):

Heating input power(kW):

Rated cooling conditions:

Rated heating conditions:

Rated piping length (m):

Rated height separation(m):

PERFORMANCE

INDOOR UNIT DETAILS

Ext. static pressure(Rated/Max)(Pa):

Max. fuse Amps MFA (A):

Page 18: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

DIMENSIONAL DRAWING

SN Part name1 Connection port of gas pipe2 Connection of liquid pipe

3 Wiring connection port of motor/pumping motor

4 Connect drain pipe5 Inlet grille6 Outlet grille7 Drain hose (accessory)

(Installed at high place)Less than 2700 to the w

all

Connect fresh air inlet accessory Φ100 (direct installation)

4-M3.2reserved hole

Greater than 1000 resreved space

210

6060 580

100

100

Less than 40

175

650 (celing open)570 (indoor units)

535 (Gap betw

wn supending rod)

Indoor units 570Less than100Decoration board 700

Pipe connection diagram

Connection drain pipe

700 (Decoration board)

60

285180175140

6060

350350 210

Suspendingbolt

4-M8-M10

170 176

195580

Adjustable (0-360)

Raise to less than 750

25

200

30

55

275 210

Page 19: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Four-way CassetteAB182MCERA

• Compact design with 950mm x 950mm panel

• Pre-set fresh air inlet to improve indoor air quality

• Built-in high lift drain pump

• Quiet operation

FEATURES & BENEFITS

Page 20: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Indoor unit name:

Indoor unit model:

Type:

Rated cooling capacity(kW):

Sensible capacity(kW):

Cooling input power(kW):

Power supply(V/Hz/Ph):

Power supply connections:

Min. circuit Amps MCA (A):

Dimensions(H×W×D)(mm):

Panel(H×W×D)(mm):

Net weight(kg):

Panel weight(kg):

Airflow rate (H/M/L)(m3/h):

Moisture removal(m3/h):

Gas pipe connection(mm):

Liquid pipe connection(mm):

Condensate connection(mm):

Sound pressure(H/M/L)(dBA):

Sound power level(H/M/L)(dBA):

Four-way Cassette

AB182MCERA

Ceiling Cassette

5.6

3.8

0.145

220-230/50/60/1

L,N, Ground

0.69

2.2

240×840×840

60×950×950

30

6

6.3

0.145

1200/1010/820

Φ12.7

Φ6.35

Φ32

34/32/30

48/46/44

0/0

Indoor(°C DB/WB):27/19Ambient(°C DB/WB):35/24

Indoor(°C DB/WB):20/14.5Ambient(°C DB/WB):7/6

Rated heating capacity(kW):

Heating input power(kW):

Rated cooling conditions:

Rated heating conditions:

Rated piping length (m):

Rated height separation(m):

PERFORMANCE

INDOOR UNIT DETAILS

Ext. static pressure(Rated/Max)(Pa):

Max. fuse Amps MFA (A):

Page 21: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

DIMENSIONAL DRAWING

SN Part name

1 Connection port of gas pipe2 Connection of liquid pipe3 Wiring connection port of motor/pumping motor4 Observe plate for water pump5 Inlet grille6 Outlet grille7 Connect drain pipe8 Drain hose (accessory)

Celing open 890

5584055

60

Gap betw

een suspending rod 780

Gap between suspending rod 910

Less than 2700 to the wall (installed at high place)

Greater than 1000 resreved space

Ceiling open680

950 (Decoration board)

Suspending

bolt 4-M10

Adjustable (0-360)

750 Raise to less than 750

240160135130

260

275

210

315475475

53

Decoration board 950

Pipe connection

diagram

Connect drain pipe

Less than100

Less than 35Less than 35

Page 22: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Four-way CassetteAB242MCERA

• Compact design with 950mm x 950mm panel

• Pre-set fresh air inlet to improve indoor air quality

• Built-in high lift drain pump

• Quiet operation

FEATURES & BENEFITS

Page 23: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Indoor unit name:

Indoor unit model:

Type:

Rated cooling capacity(kW):

Sensible capacity(kW):

Cooling input power(kW):

Power supply(V/Hz/Ph):

Power supply connections:

Min. circuit Amps MCA (A):

Dimensions(H×W×D)(mm):

Panel(H×W×D)(mm):

Net weight(kg):

Panel weight(kg):

Airflow rate (H/M/L)(m3/h):

Moisture removal(m3/h):

Gas pipe connection(mm):

Liquid pipe connection(mm):

Condensate connection(mm):

Sound pressure(H/M/L)(dBA):

Sound power level(H/M/L)(dBA):

Four-way Cassette

AB242MCERA

Ceiling Cassette

7.1

4.7

0.145

220-230/50/60/1

L,N, Ground

0.69

2.2

240×840×840

60×950×950

30

6

8

0.145

1200/1010/820

Φ15.88

Φ9.52

Φ32

35/34/31

49/48/45

0/0

Indoor(°C DB/WB):27/19Ambient(°C DB/WB):35/24

Indoor(°C DB/WB):20/14.5Ambient(°C DB/WB):7/6

Rated heating capacity(kW):

Heating input power(kW):

Rated cooling conditions:

Rated heating conditions:

Rated piping length (m):

Rated height separation(m):

PERFORMANCE

INDOOR UNIT DETAILS

Ext. static pressure(Rated/Max)(Pa):

Max. fuse Amps MFA (A):

Page 24: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

DIMENSIONAL DRAWING

SN Part name

1 Connection port of gas pipe2 Connection of liquid pipe3 Wiring connection port of motor/pumping motor4 Observe plate for water pump5 Inlet grille6 Outlet grille7 Connect drain pipe8 Drain hose (accessory)

Celing open 890

5584055

60

Gap betw

een suspending rod 780

Gap between suspending rod 910

Less than 2700 to the wall (installed at high place)

Greater than 1000 resreved space

Ceiling open680

950 (Decoration board)

Suspending

bolt 4-M10

Adjustable (0-360)

750 Raise to less than 750

240160135130

260

275

210

315475475

53

Decoration board 950

Pipe connection

diagram

Connect drain pipe

Less than100

Less than 35Less than 35

Page 25: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Four-way CassetteAB282MCERA

• Compact design with 950mm x 950mm panel

• Pre-set fresh air inlet to improve indoor air quality

• Built-in high lift drain pump

• Quiet operation

FEATURES & BENEFITS

Page 26: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Indoor unit name:

Indoor unit model:

Type:

Rated cooling capacity(kW):

Sensible capacity(kW):

Cooling input power(kW):

Power supply(V/Hz/Ph):

Power supply connections:

Min. circuit Amps MCA (A):

Dimensions(H×W×D)(mm):

Panel(H×W×D)(mm):

Net weight(kg):

Panel weight(kg):

Airflow rate (H/M/L)(m3/h):

Moisture removal(m3/h):

Gas pipe connection(mm):

Liquid pipe connection(mm):

Condensate connection(mm):

Sound pressure(H/M/L)(dBA):

Sound power level(H/M/L)(dBA):

Four-way Cassette

AB282MCERA

Ceiling Cassette

8

5.2

0.145

220-230/50/60/1

L,N, Ground

0.69

2.2

240×840×840

60×950×950

30

6

9

0.145

1200/1010/820

Φ15.88

Φ9.52

Φ32

37/35/31

51/49/45

0/0

Indoor(°C DB/WB):27/19Ambient(°C DB/WB):35/24

Indoor(°C DB/WB):20/14.5Ambient(°C DB/WB):7/6

Rated heating capacity(kW):

Heating input power(kW):

Rated cooling conditions:

Rated heating conditions:

Rated piping length (m):

Rated height separation(m):

PERFORMANCE

INDOOR UNIT DETAILS

Ext. static pressure(Rated/Max)(Pa):

Max. fuse Amps MFA (A):

Page 27: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

DIMENSIONAL DRAWING

SN Part name

1 Connection port of gas pipe2 Connection of liquid pipe3 Wiring connection port of motor/pumping motor4 Observe plate for water pump5 Inlet grille6 Outlet grille7 Connect drain pipe8 Drain hose (accessory)

Celing open 890

5584055

60

Gap betw

een suspending rod 780

Gap between suspending rod 910

Less than 2700 to the wall (installed at high place)

Greater than 1000 resreved space

Ceiling open680

950 (Decoration board)

Suspending

bolt 4-M10

Adjustable (0-360)

750 Raise to less than 750

240160135130

260

275

210

315475475

53

Decoration board 950

Pipe connection

diagram

Connect drain pipe

Less than100

Less than 35Less than 35

Page 28: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Four-way CassetteAB302MCERA

• Compact design with 950mm x 950mm panel

• Pre-set fresh air inlet to improve indoor air quality

• Built-in high lift drain pump

• Quiet operation

FEATURES & BENEFITS

Page 29: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Indoor unit name:

Indoor unit model:

Type:

Rated cooling capacity(kW):

Sensible capacity(kW):

Cooling input power(kW):

Power supply(V/Hz/Ph):

Power supply connections:

Min. circuit Amps MCA (A):

Dimensions(H×W×D)(mm):

Panel(H×W×D)(mm):

Net weight(kg):

Panel weight(kg):

Airflow rate (H/M/L)(m3/h):

Moisture removal(m3/h):

Gas pipe connection(mm):

Liquid pipe connection(mm):

Condensate connection(mm):

Sound pressure(H/M/L)(dBA):

Sound power level(H/M/L)(dBA):

Four-way Cassette

AB302MCERA

Ceiling Cassette

9

6.1

0.15

220-230/50/60/1

L,N, Ground

1.38

4.4

295×840×840

60×950×950

38

6

10

0.15

1800/1610/1420

Φ15.88

Φ9.52

Φ32

37/35/31

51/49/45

0/0

Indoor(°C DB/WB):27/19Ambient(°C DB/WB):35/24

Indoor(°C DB/WB):20/14.5Ambient(°C DB/WB):7/6

Rated heating capacity(kW):

Heating input power(kW):

Rated cooling conditions:

Rated heating conditions:

Rated piping length (m):

Rated height separation(m):

PERFORMANCE

INDOOR UNIT DETAILS

Ext. static pressure(Rated/Max)(Pa):

Max. fuse Amps MFA (A):

Page 30: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

DIMENSIONAL DRAWING

lla

w eh

t ot

0072

nah

t ss

eL

4-M3.2 reserved hole

Connect fresh air inlet accessory (direct installation)

098

nepo

gnil

i eC

eca

ps d

ever

ser

0001

nah

t ret

aer

G

Less than 35Less than 35

55 840 55

087

dor

gni d

neps

us n

eewt

eb p

aG

) dr a

ob n

oitar

oce

D( 05

9

057

naht

ssel

ot es

i aR

057

) 063

- 0(

elba

t suj

dA

Suspending bolt4-M10

012 59

2

051

041

021

475475315

260295

04

Connect drain pipe

Decoration board 950

Pipe connectiondiagram

Ceiling open 910Gap between suspending rod 680100

55

70

7021

0

SN Part name1 Connection port of gas pipe2 Connection of liquid pipe3 Wiring connection port of motor/pumping motor4 Observe plate for water pump5 Inlet grille6 Outlet grille7 Connect drain pipe8 Drain hose (accessory)

edis A morf eeS

275

210

60

Page 31: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Four-way CassetteAB382MCERA

• Compact design with 950mm x 950mm panel

• Pre-set fresh air inlet to improve indoor air quality

• Built-in high lift drain pump

• Quiet operation

FEATURES & BENEFITS

Page 32: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Indoor unit name:

Indoor unit model:

Type:

Rated cooling capacity(kW):

Sensible capacity(kW):

Cooling input power(kW):

Power supply(V/Hz/Ph):

Power supply connections:

Min. circuit Amps MCA (A):

Dimensions(H×W×D)(mm):

Panel(H×W×D)(mm):

Net weight(kg):

Panel weight(kg):

Airflow rate (H/M/L)(m3/h):

Moisture removal(m3/h):

Gas pipe connection(mm):

Liquid pipe connection(mm):

Condensate connection(mm):

Sound pressure(H/M/L)(dBA):

Sound power level(H/M/L)((dBA):

Four-way Cassette

AB382MCERA

Ceiling Cassette

11.2

7.8

0.15

220-230/50/60/1

L,N, Ground

1.38

4.4

295×840×840

60×950×950

38

6

12.5

0.15

1800/1610/1420

Φ15.88

Φ9.52

Φ32

37/35/31

51/49/45

0/0

Indoor(°C DB/WB):27/19Ambient(°C DB/WB):35/24

Indoor(°C DB/WB):20/14.5Ambient(°C DB/WB):7/6

Rated heating capacity(kW):

Heating input power(kW):

Rated cooling conditions:

Rated heating conditions:

Rated piping length (m):

Rated height separation(m):

PERFORMANCE

INDOOR UNIT DETAILS

Ext. static pressure(Rated/Max)(Pa):

Max. fuse Amps MFA (A):

Page 33: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

DIMENSIONAL DRAWING

lla

w eh

t ot

0072

nah

t ss

eL

4-M3.2 reserved hole

Connect fresh air inlet accessory (direct installation)

098

nepo

gnil

i eC

eca

ps d

ever

ser

0001

nah

t ret

aer

G

Less than 35Less than 35

55 840 55

087

dor

gni d

neps

us n

eewt

eb p

aG

) dr a

ob n

oitar

oce

D( 05

9

057

naht

ssel

ot es

i aR

057

) 063

- 0(

elba

t suj

dA

Suspending bolt4-M10

012 59

2

051

041

021

475475315

260295

04

Connect drain pipe

Decoration board 950

Pipe connectiondiagram

Ceiling open 910Gap between suspending rod 680100

55

70

7021

0

SN Part name1 Connection port of gas pipe2 Connection of liquid pipe3 Wiring connection port of motor/pumping motor4 Observe plate for water pump5 Inlet grille6 Outlet grille7 Connect drain pipe8 Drain hose (accessory)

edis A morf eeS

275

210

60

Page 34: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Four-way CassetteAB482MCERA

• Compact design with 950mm x 950mm panel

• Pre-set fresh air inlet to improve indoor air quality

• Built-in high lift drain pump

• Quiet operation

FEATURES & BENEFITS

Page 35: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

Indoor unit name:

Indoor unit model:

Type:

Rated cooling capacity(kW):

Sensible capacity(kW):

Cooling input power(kW):

Power supply(V/Hz/Ph):

Power supply connections:

Min. circuit Amps MCA (A):

Dimensions(H×W×D)(mm):

Panel(H×W×D)(mm):

Net weight(kg):

Panel weight(kg):

Airflow rate (H/M/L)(m3/h):

Moisture removal(m3/h):

Gas pipe connection(mm):

Liquid pipe connection(mm):

Condensate connection(mm):

Sound pressure(H/M/L)(dBA):

Sound power level(H/M/L)(dBA):

Four-way Cassette

AB482MCERA

Ceiling Cassette

14

9.2

0.15

220-230/50/60/1

L,N, Ground

1.38

4.4

295×840×840

60×950×950

38

6

16

0.15

1800/1610/1420

Φ15.88

Φ9.52

Φ32

42/39/35

56/53/49

0/0

Indoor(°C DB/WB):27/19Ambient(°C DB/WB):35/24

Indoor(°C DB/WB):20/14.5Ambient(°C DB/WB):7/6

Rated heating capacity(kW):

Heating input power(kW):

Rated cooling conditions:

Rated heating conditions:

Rated piping length (m):

Rated height separation(m):

PERFORMANCE

INDOOR UNIT DETAILS

Ext. static pressure(Rated/Max)(Pa):

Max. fuse Amps MFA (A):

Page 36: Four-way Cassette

Haier Commercial Air ConditionADDRESS: NO.1 Haier Road,Hi-tech Zone, Qingdao 266101 P.R.China Haier reserves the right to make change without any notice.

Web: Http://www.haier.com

Submittal Data Sheet

DIMENSIONAL DRAWING

lla

w eh

t ot

0072

nah

t ss

eL

4-M3.2 reserved hole

Connect fresh air inlet accessory (direct installation)

098

nepo

gnil

i eC

eca

ps d

ever

ser

0001

nah

t ret

aer

G

Less than 35Less than 35

55 840 55

087

dor

gni d

neps

us n

eewt

eb p

aG

) dr a

ob n

oitar

oce

D( 05

9

057

naht

ssel

ot es

i aR

057

) 063

- 0(

elba

t suj

dA

Suspending bolt4-M10

012 59

2

051

041

021

475475315

260295

04

Connect drain pipe

Decoration board 950

Pipe connectiondiagram

Ceiling open 910Gap between suspending rod 680100

55

70

7021

0

SN Part name1 Connection port of gas pipe2 Connection of liquid pipe3 Wiring connection port of motor/pumping motor4 Observe plate for water pump5 Inlet grille6 Outlet grille7 Connect drain pipe8 Drain hose (accessory)

edis A morf eeS

275

210

60