Fortimo
LEDFortimo DLM R1112000lm
Datasheet
Fortimo DLM R111Continues to focus on the combination of Quality of Light and performance, Fortimo DLM R111 Range fully leverageour expertise in retail and integrated with heatsink and optics to make it extremely easy to design and use to ourOEM customers who can fully focus on luminaire outlook design.
Key features and benefitsSimilar form factor as CDM R111 which makes easy to useDedicated heatsink and optic design deliver optimized systemFlux ranges covers 2000lm, 3000lm, 4000lm (nominal)High quality of light with 2700K, 3000K PW, and 4000K PW fullfill most of application with CRI90System approach50,000 hours lifetime
March 2020
Ordering data
Commercial product name EOC 12NC Box quantityFortimo DLM R111 2000lm 927 24D 8718699 785536 00 9290 028 06006 24
Fortimo DLM R111 2000lm 927 36D 8718699 785598 00 9290 028 06306 24
Fortimo DLM R111 2000lm 927 60D 8718699 785659 00 9290 028 06606 24
Fortimo DLM R111 2000lm 930 PW 24D 8718699 785550 00 9290 028 06106 24
Fortimo DLM R111 2000lm 930 PW 36D 8718699 785611 00 9290 028 06406 24
Fortimo DLM R111 2000lm 930 PW 60D 8718699 785673 00 9290 028 06706 24
Fortimo DLM R111 2000lm 940 PW 24D 8718699 785574 00 9290 028 06206 24
Fortimo DLM R111 2000lm 940 PW 36D 8718699 785635 00 9290 028 06506 24
Fortimo DLM R111 2000lm 940 PW 60D 8718699 785697 00 9290 028 06806 24
Drive currents
Parameter Nominal* Life** Max*** UnitFortimo DLM R111 2000lm 600 700 700 mA
Module temperatures
Parameter Nominal* Life** Max*** UnitTc (case temperature at Tc point) 50 80 80 °C
* Nominal value at which typical performance is specified
** Value at which life time is specified
*** Maximum value for safe operation, do not operate above this value
2 Datasheet - Fortimo DLM R111 2000lm March, 2020
Optical characteristics - table per color (CCT)
Fortimo DLM R111 2000lm 927 24D
Parameter Min Typ Max UnitLuminous flux 1953 2170 2387 lm
Flux within 90° cone 2078 lm
Module efficacy 103 lm/W
Correlated color temperature (CCT) 2700 K
Color coordinates (CIEx, CIEy) (0.458, 0.411) -
Color consistency 3 SDCM
CRI 90
R9 50
Photometric code 927/359
Radiation angle 24 deg
Peak intensity 8950 cd
Photobiological safety RG1 unlimited
Measurement precision for flux +/- 5%. Measurement precision for x, y +/- 0.005. Measurement precision for CRI 1.5
Operation point 927 lm lm/WTc 25 °C 1857 111
80% I-nom 480mA Tc-nom 50 °C 1788 108Tc-max 80 °C 1704 104Tc 25 °C 2249 106
I-nom 600mA Tc-nom 50 °C 2170 103Tc-max 80 °C 2048 98Tc 25 °C 2555 101
I-max 700mA Tc-nom 50 °C 2448 98Tc-max 80 °C 2315 94
3 Datasheet - Fortimo DLM R111 2000lm March, 2020
Fortimo DLM R111 2000lm 927 36D
Parameter Min Typ Max UnitLuminous flux 1971 2190 2409 lm
Flux within 90° cone 2105 lm
Module efficacy 104 lm/W
Correlated color temperature (CCT) 2700 K
Color coordinates (CIEx, CIEy) (0.458, 0.411) -
Color consistency 3 SDCM
CRI 90
R9 50
Photometric code 927/359
Radiation angle 36 deg
Peak intensity 5480 cd
Photobiological safety RG1 unlimited
Measurement precision for flux +/- 5%. Measurement precision for x, y +/- 0.005. Measurement precision for CRI 1.5
Operation point 927 lm lm/WTc 25 °C 1875 112
80% I-nom 480mA Tc-nom 50 °C 1805 109Tc-max 80 °C 1720 105Tc 25 °C 2271 107
I-nom 600mA Tc-nom 50 °C 2190 104Tc-max 80 °C 2068 99Tc 25 °C 2580 102
I-max 700mA Tc-nom 50 °C 2472 99Tc-max 80 °C 2338 95
4 Datasheet - Fortimo DLM R111 2000lm March, 2020
Fortimo DLM R111 2000lm 927 60D
Parameter Min Typ Max UnitLuminous flux 1971 2190 2409 lm
Flux within 90° cone 2826 lm
Module efficacy 104 lm/W
Correlated color temperature (CCT) 2700 K
Color coordinates (CIEx, CIEy) (0.458, 0.411) -
Color consistency 3 SDCM
CRI 90
R9 50
Photometric code 927/359
Radiation angle 60 deg
Peak intensity 1930 cd
Photobiological safety RG1 unlimited
Measurement precision for flux +/- 5%. Measurement precision for x, y +/- 0.005. Measurement precision for CRI 1.5
Operation point 927 lm lm/WTc 25 °C 1875 112
80% I-nom 480mA Tc-nom 50 °C 1805 109Tc-max 80 °C 1720 105Tc 25 °C 2271 107
I-nom 600mA Tc-nom 50 °C 2190 104Tc-max 80 °C 2068 99Tc 25 °C 2580 102
I-max 700mA Tc-nom 50 °C 2472 99Tc-max 80 °C 2338 95
5 Datasheet - Fortimo DLM R111 2000lm March, 2020
Fortimo DLM R111 2000lm 930 PW 24D
Parameter Min Typ Max UnitLuminous flux 2025 2250 2475 lm
Flux within 90° cone 2154 lm
Module efficacy 107 lm/W
Correlated color temperature (CCT) 3000 K
Color coordinates (CIEx, CIEy) (0.423, 0.387) -
Color consistency 3 SDCM
CRI 90
R9 50
Photometric code 930/359
Radiation angle 24 deg
Peak intensity 8910 cd
Photobiological safety RG1 unlimited
Measurement precision for flux +/- 5%. Measurement precision for x, y +/- 0.005. Measurement precision for CRI 1.5
Operation point 930 lm lm/WTc 25 °C 1925 115
80% I-nom 480mA Tc-nom 50 °C 1854 112Tc-max 80 °C 1766 108Tc 25 °C 2333 110
I-nom 600mA Tc-nom 50 °C 2250 107Tc-max 80 °C 2124 102Tc 25 °C 2650 105
I-max 700mA Tc-nom 50 °C 2539 102Tc-max 80 °C 2402 97
6 Datasheet - Fortimo DLM R111 2000lm March, 2020
Fortimo DLM R111 2000lm 930 PW 36D
Parameter Min Typ Max UnitLuminous flux 2043 2270 2497 lm
Flux within 90° cone 2181 lm
Module efficacy 107 lm/W
Correlated color temperature (CCT) 3000 K
Color coordinates (CIEx, CIEy) (0.423, 0.387) -
Color consistency 3 SDCM
CRI 90
R9 50
Photometric code 930/359
Radiation angle 36 deg
Peak intensity 5680 cd
Photobiological safety RG1 unlimited
Measurement precision for flux +/- 5%. Measurement precision for x, y +/- 0.005. Measurement precision for CRI 1.5
Operation point 930 lm lm/WTc 25 °C 1943 116
80% I-nom 480mA Tc-nom 50 °C 1871 113Tc-max 80 °C 1783 109Tc 25 °C 2354 111
I-nom 600mA Tc-nom 50 °C 2270 107Tc-max 80 °C 2144 103Tc 25 °C 2675 106
I-max 700mA Tc-nom 50 °C 2563 103Tc-max 80 °C 2424 98
7 Datasheet - Fortimo DLM R111 2000lm March, 2020
Fortimo DLM R111 2000lm 930 PW 60D
Parameter Min Typ Max UnitLuminous flux 2043 2270 2497 lm
Flux within 90° cone 3181 lm
Module efficacy 107 lm/W
Correlated color temperature (CCT) 3000 K
Color coordinates (CIEx, CIEy) (0.423, 0.387) -
Color consistency 3 SDCM
CRI 90
R9 50
Photometric code 930/359
Radiation angle 60 deg
Peak intensity 2000 cd
Photobiological safety RG1 unlimited
Measurement precision for flux +/- 5%. Measurement precision for x, y +/- 0.005. Measurement precision for CRI 1.5
Operation point 930 lm lm/WTc 25 °C 1943 116
80% I-nom 480mA Tc-nom 50 °C 1871 113Tc-max 80 °C 1783 109Tc 25 °C 2354 111
I-nom 600mA Tc-nom 50 °C 2270 107Tc-max 80 °C 2144 103Tc 25 °C 2675 106
I-max 700mA Tc-nom 50 °C 2563 103Tc-max 80 °C 2424 98
8 Datasheet - Fortimo DLM R111 2000lm March, 2020
Fortimo DLM R111 2000lm 940 PW 24D
Parameter Min Typ Max UnitLuminous flux 2223 2470 2717 lm
Flux within 90° cone 2365 lm
Module efficacy 117 lm/W
Correlated color temperature (CCT) 4000 K
Color coordinates (CIEx, CIEy) (0.376, 0.368) -
Color consistency 3 SDCM
CRI 90
R9 50
Photometric code 940/359
Radiation angle 24 deg
Peak intensity 9780 cd
Photobiological safety RG1 unlimited
Measurement precision for flux +/- 5%. Measurement precision for x, y +/- 0.005. Measurement precision for CRI 1.5
Operation point 940 lm lm/WTc 25 °C 2114 127
80% I-nom 480mA Tc-nom 50 °C 2036 123Tc-max 80 °C 1940 119Tc 25 °C 2562 120
I-nom 600mA Tc-nom 50 °C 2470 117Tc-max 80 °C 2334 112Tc 25 °C 2912 115
I-max 700mA Tc-nom 50 °C 2791 112Tc-max 80 °C 2640 107
9 Datasheet - Fortimo DLM R111 2000lm March, 2020
Fortimo DLM R111 2000lm 940 PW 36D
Parameter Min Typ Max UnitLuminous flux 2232 2480 2728 lm
Flux within 90° cone 2383 lm
Module efficacy 117 lm/W
Correlated color temperature (CCT) 4000 K
Color coordinates (CIEx, CIEy) (0.376, 0.368) -
Color consistency 3 SDCM
CRI 90
R9 50
Photometric code 940/359
Radiation angle 36 deg
Peak intensity 6200 cd
Photobiological safety RG1 unlimited
Measurement precision for flux +/- 5%. Measurement precision for x, y +/- 0.005. Measurement precision for CRI 1.5
Operation point 940 lm lm/WTc 25 °C 2122 127
80% I-nom 480mA Tc-nom 50 °C 2044 124Tc-max 80 °C 1948 119Tc 25 °C 2573 121
I-nom 600mA Tc-nom 50 °C 2480 117Tc-max 80 °C 2344 112Tc 25 °C 2924 116
I-max 700mA Tc-nom 50 °C 2802 112Tc-max 80 °C 2651 107
10 Datasheet - Fortimo DLM R111 2000lm March, 2020
Fortimo DLM R111 2000lm 940 PW 60D
Parameter Min Typ Max UnitLuminous flux 2232 2480 2728 lm
Flux within 90° cone 3446 lm
Module efficacy 117 lm/W
Correlated color temperature (CCT) 4000 K
Color coordinates (CIEx, CIEy) (0.376, 0.368) -
Color consistency 3 SDCM
CRI 90
R9 50
Photometric code 940/359
Radiation angle 60 deg
Peak intensity 2180 cd
Photobiological safety RG1 unlimited
Measurement precision for flux +/- 5%. Measurement precision for x, y +/- 0.005. Measurement precision for CRI 1.5
Operation point 940 lm lm/WTc 25 °C 2122 127
80% I-nom 480mA Tc-nom 50 °C 2044 124Tc-max 80 °C 1948 119Tc 25 °C 2573 121
I-nom 600mA Tc-nom 50 °C 2480 117Tc-max 80 °C 2344 112Tc 25 °C 2924 116
I-max 700mA Tc-nom 50 °C 2802 112Tc-max 80 °C 2651 107
11 Datasheet - Fortimo DLM R111 2000lm March, 2020
Beam shape
Light distribution of the 24D product
Light distribution of the 36D product
Light distribution of the 60D product
12 Datasheet - Fortimo DLM R111 2000lm March, 2020
Electrical characteristics
Parameter Min Typ Max UnitForward voltage 32.7 35.2 37.7 V
Power consumption 19.6 21.1 22.6 W = kWh/1000h
Number of modules in series per chain 1
Number of modules in parallel 1
Measurement precision for Vf +/- 3%. Measurement precision for power +/- 3.3%.
Tuning information
Flux and efficacy versus current (at Tc nominal)
I [mA] Flux [%] Efficacy [%]700 113 96
650 107 98
600 100 100
480 83 105
300 54 114
Flux and efficacy versus temperature at Tc (at I nominal)
Tc [°C] Flux [%] Efficacy [%]80 95 96
50 100 100
25 104 103
0 108 106
13 Datasheet - Fortimo DLM R111 2000lm March, 2020
Lumen maintenance
Operation point Lumen maintenance L70 L80 L90x 1000 hours B50 B20 B10 B50 B20 B10 B50 B20 B10
480 mA Tc_nom 50°C >50 >50 >50 >50 >50 >50 >50 45 36Tc_max 80°C >50 >50 >50 >50 >50 45 40 26 21
600 mA Tc_nom 50°C >50 >50 >50 >50 >50 >50 >50 41 33Tc_max 80°C >50 >50 >50 >50 >50 41 36 25 19
700 mA Tc_nom 50°C >50 >50 >50 >50 >50 >50 >50 37 30Tc_max 80°C >50 >50 >50 >50 47 37 34 22 18
Lifetime
Parameter Value UnitM70F50 nominal >50000 hours
M70F50 life >50000 hours
Performance Window
Wiring
Specification item Value Unit ConditionInput wire cross-section 1.2...1.4 mm2 fused
16...16 AWG fused
Input wire strip length 8.5...9.5 mm
14 Datasheet - Fortimo DLM R111 2000lm March, 2020
Mechanical characteristics
Parameter Min Typ Max UnitLength 110 111 111 mm
Width 110 111 111 mm
Height 50.5 52 53.5 mm
Product mass 355 gram
Absolute ratings
Parameter Min Max UnitCurrent through the LED module (I-max) 700 mA
Case temperature (Tc-max) 80 °C
Power at rated Vf-max and I-max 22.6 W
ESD (direct contact) 8 kV
Working voltage 60 Vdc
Ambient temperature -25 40 °C
Storage temperature -40 80 °C
15 Datasheet - Fortimo DLM R111 2000lm March, 2020
Application information
Certificates and StandardsIEC 62031:2018IEC/TR 62778:2014According to IEC 62598-1 - Cl. 4 Construction - Cl. 5 External and internal wiring - Cl. 9 Resistance to dust and moisture - Cl. 12 Endurance test and thermal test
ApplicationDimming Yes
16 Datasheet - Fortimo DLM R111 2000lm March, 2020
© 2020 Signify Holding, IBRS 10461, 5600VB, NL. All rights reserved. The information provided hereinis subject to change, without notice. Signify does not give any representation or warranty as to theaccuracy or completeness of the information included herein and shall not be liable for any action inreliance thereon. The information presented in this document is not intended as any commercial offerand does not form part of any quotation or contract, unless otherwise agreed by Signify.
Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V. All othertrademarks are owned by Signify Holding or their respective owners.
23/03/2020
www.philips.com/oem