12
Model No. CZPP100CN Model No. CZPP200CN Conforms to ANSI STD Z83.7b-2011 Certified to CSA STD 2.14b-2009 Forced-Air Propane (LP) Gas Heater PLEASE READ MANUAL CAREFULLY BEFORE RUNNING THIS HEATER AND SAVE IT FOR FUTURE REFERENCE GENERAL HAZARD WARNING: Failure to comply with the precautions and instructions provided with this heater can result in death, serious bodily injury, property loss, or damage from hazards of fire, explosion, burn, asphyxiation, carbon monoxide poisoning, and/or electric shock. Only persons who can understand and follow the instructions should use or service this heater. if you need assistance or heater information such as an instruction manual label, etc. contact the manufacturer WARNING: fire, Burn, inhalation and explosion hazard. Keep solid combustibles, such as building materials, paper or cardboard a safe distance away from the heater as recommended by the instructions. Never use the heater in spaces which do or may contain volatile or airborne combustibles or airborne. WARNING: Not for home or recreational vehicle use. This is an unvented gas-fired portable heater. It uses air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided.

Forced-Air Propane (LP) Gas Heatercomfortzone-us.com/temp/CZPP100_manual.pdf · Use only propane (LP) gas. 4. Use only VAPOR WITHDRAWAL propane (LP) supply. If there is any question

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Forced-Air Propane (LP) Gas Heatercomfortzone-us.com/temp/CZPP100_manual.pdf · Use only propane (LP) gas. 4. Use only VAPOR WITHDRAWAL propane (LP) supply. If there is any question

Model No. CZPP100CNModel No. CZPP200CN

Conforms to ANSI STD Z83.7b-2011Certified to CSA STD 2.14b-2009

Instruction Manual

Forced-AirPropane (LP) Gas Heater

PLEASE READ MANUAL CAREFULLY BEFORE RUNNING THIS HEATER AND SAVE IT FOR FUTURE REFERENCE

GENERAL HAZARD WARNING:

Failure to comply with the precautions and instructions provided with this heater can result in death, serious bodily injury, property loss, or damage from hazards of fire, explosion, burn, asphyxiation, carbon monoxide poisoning, and/or electric shock. Only persons who can understand and follow the instructions should use or service this heater. if you need assistance or heater information such as an instruction manual label, etc. contact the manufacturer

WARNING: fire, Burn, inhalation and explosion hazard. Keep solid combustibles, such as building materials, paper or cardboard a safe distance away from the heater as recommended by the instructions. Never use the heater in spaces which do or may contain volatile or airborne combustibles or airborne.

WARNING: Not for home or recreational vehicle use. This is an unvented gas-fired portable heater. It uses air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided.

Page 2: Forced-Air Propane (LP) Gas Heatercomfortzone-us.com/temp/CZPP100_manual.pdf · Use only propane (LP) gas. 4. Use only VAPOR WITHDRAWAL propane (LP) supply. If there is any question

2

Model No. CZPP100CN | Model No. CZPP200CN

SP

EC

IFIC

AT

ION

SC

ON

TE

NT

S

Contents/Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Getting to Know Your Gas Heater. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6

Fuel Gases/Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Operation and Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9

Safety Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Maintenance and Storage/ Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Wiring Diagram/Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Dear Customer:

Congratulations on your purchase of this heater. We want you to be satisfied with your purchase. To operate this heater safely, you must observe certain rules. Before use of this heater, refer to the contents of this manual. All explanations, warnings and safety guidelines must be strictly adhered to. After reading, please keep this manual for future reference. Note: This unit is not suitable for use on wood floors or near other combustible materials.

If there is doubt about this heaters use, this instruction manual or warnings, please contact Comfort Zone® to clarify.

Stock No CZPP100 CZPP200

Rated Voltage 120V~60Hz 120V~60Hz

Rated Input 33W 33W

Heat Output 34,000 BTUs 52,000 BTUs

Air Flow 300m3/h 300m3/h

Gas Consumption 1.57 lb/hr (0.71kg/h) 2.36 lb/hr (1.07kg/h)

Weight (Approx.) 10.8 lb (4.9kg) 11.55 lb (5.24kg)

Fuel Type Propane Propane

Regulator Pressure Output 5.0 PSI 5.0 PSI

Min. Gas Cylinder Size 20LB 20LB

Air Delivery Temperature Classification Space Heating Appliance Space Heating Appliance

Safety Distances Sides - 2ft. (0.6m.), Top - 6ft (1.8m.), Front - 8ft. (2.4m.)

Sides - 2ft. (0.6m.), Top - 6ft (1.8m.), Front - 8ft. (2.4m.)

Ventilation Requirements 30cm³ per kW of Heat Output 30cm³ per kW of Heat Output

Page 3: Forced-Air Propane (LP) Gas Heatercomfortzone-us.com/temp/CZPP100_manual.pdf · Use only propane (LP) gas. 4. Use only VAPOR WITHDRAWAL propane (LP) supply. If there is any question

3

Model No. CZPP100CN | Model No. CZPP200CN

A. On/Off Switch

B. Safety Start Valve Button

C. Gas Inlet

D. Ignition Button

E. Handle

F. Power Cord

Always maintain proper clearance from combustible materials.

Minimum clearance should be: Sides - 2ft. (0.6m.), Top - 6ft (1.8m.), Front - 8ft. (2.4m.)

UNPACKING: After removing the packing material, make sure the product is in perfect condition and that there are no visible damaged parts. If in doubt, do not use the product and contact the dealer from whom it was purchased. Do not use until unit has been repaired.

The packaging materials (plastic bags, polystyrene, etc.) must be disposed of in an appropriate refuse collection container. These materials must not be left within the reach of children as they are potential sources of danger.

GE

TT

ING

TO K

NO

W Y

OU

R G

AS

HE

AT

ER

S

A

B

C

D

E

F

Page 4: Forced-Air Propane (LP) Gas Heatercomfortzone-us.com/temp/CZPP100_manual.pdf · Use only propane (LP) gas. 4. Use only VAPOR WITHDRAWAL propane (LP) supply. If there is any question

4

Model No. CZPP100CN | Model No. CZPP200CN

PR

EC

AU

TIO

NS

This manual contains important information about the assembly, operation and maintenance of this indoor propane (LP) appliance. General safety information is presented throughout this manual. Please read it thoroughly and carefully. Particular attention should be paid to the information accompanied by safety alert symbols:

! DANGER, ! WARNING, ! CAUTION

Save this manual for future reference and to educate new users of this product. This instruction manual should be read in conjunction with the labeling on the product.

Extra safety precautions are essential when using any type of heater, either mechanical or propane. These precautions are required when using, storing and servicing. Using this equipment with the caution and respect that this product demands will reduce the possibilities of personal injuries or property damage.

The symbols shown below are used often throughout these instructions. Always follow the precautions as they are essential for the safe operation of any mechanical or propane (LP) fueled equipment.

! DANGER

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

! WARNING

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

! CAUTION

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate personal injury, or property damage.

CALIFORNIA PROPOSITION 65 WARNING:

This device, it’s fuel and byproducts of combustion of this fuel, may contain chemicals known to the state of California to cause cancer, birth defects, or other reproductive harm.

! DANGER

Failure to comply with all precautions and instructions provided with this propane (LP)heater can result in death, serious bodily injury and property loss or damage from hazards of fire, explosion, burn, asphyxiation, and/or carbon monoxide poisoning.Only persons who can understand and follow these instructions should use or service this heater.If you need assistance or information such as an instruction manual or safety labels, contact Comfort Zone®.

FOR YOUR SAFETY

If you smell gas:1. Do not attempt to light

the unit.2. Extinguish any open flames.3. Disconnect unit from fuel

supply.

FOR YOUR SAFETY

Do not store or use gasoline or other liquids with flammable vapors in the vicinity of this or any other appliances.

DANGER CARBON MONOXIDE HAZARD

• This unit can produce carbon monoxide which has no odor.

• Using this unit in an enclosed space can kill you.

• Never use this unit in an enclosed space such as a camper, tent, car, or home.

Page 5: Forced-Air Propane (LP) Gas Heatercomfortzone-us.com/temp/CZPP100_manual.pdf · Use only propane (LP) gas. 4. Use only VAPOR WITHDRAWAL propane (LP) supply. If there is any question

5

Model No. CZPP100CN | Model No. CZPP200CN

GE

NE

RA

L S

AF

ET

Y IN

ST

RU

CT

ION

S

SAFETY PRECAUTIONS

1. Check the heater thoroughly for damage. DO NOT operate a damaged heater.

2. DO NOT modify the heater or operate a heater which has been modified from its original condition.

3. Use only propane (LP) gas.4. Use only VAPOR WITHDRAWAL propane (LP) supply.

If there is any question about vapor withdrawal, ask your propane dealer.

5. Mount the propane cylinders vertically (shutoff valve up). Secure them from falling or being knocked over and protect them from damage.

6. Locate propane (LP) containers at least (USA) 7 ft. (2.13m), (Canada) 10 ft. (3m) from the heater and do not direct exhaust toward containers.

7. The gas heaters must only be used on fire-resistant floors.8. IMPORTANT Use only the hose and regulator

assembly provided with the heater. Inspect hose assembly before each use of the heater. If there is excessive abrasion or wear, or hose is cut, replace with hose assembly listed on parts list before using heater.

9. For indoor use only. Area must be well ventilated. Provide minimum openings of 1/2 sq. ft. (.046 m²) near the floor and 1/2 sq. ft. (.046 m²) near the ceiling (also see "Operating Precautions").

10. If at any time gas odor is detected, IMMEDIATELY DISCONTINUE operation until the source of gas has been located and corrected.

11. Install the heater such that it is not directly exposed to water spray, rain and/or dripping water.

12. Maintain minimum clearance from normal combustible material (like paper) as follows: outlet-8 ft. (2.4 m); sides-2 ft. (.6 m); top-6 ft. (1.8 m). Locate 10 ft. (3 m) from canvas or plastic tarpaulins or similar coverings and secure them to prevent flapping or movement due to wind or other actions.

13. Due to the high surface and exhaust temperatures, adults and children must observe clearances to avoid burns or clothing ignition. Keep away from children and mentally impaired adults

14. Operate only on a stable, level surface.15. Do not use with ductwork. Do not restrict air inlet or exit.16. Use only the electrical power specified. The electrical

connection and grounding must comply with National and Local Electrical Codes

17. This appliance has a three prong grounded plug that must be inserted into a matching properly grounded outlet to reduce the risk of electrical shock. Do not defeat this safety feature. Use only a properly grounded 3-prong extension cord.

18. Do not move, handle or service while hot or burning.19. Use only in accordance with local codes or, in the

absence of local codes, with the Standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane Installation Code.

WARNING: Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. This is a propane (LP), direct-fired, forced air heater. It's intended use is primarily temporary heating of buildings under construction, alteration or repair.

SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCEPropane gas is heavier than air. If propane leaks from a connection or fitting, it sinks to the floor, collecting there with the surrounding air, forming a potentially explosive mixture. Propane leaks must be avoided, set up the propane supply carefully. Check all new connections or re-connections with a 50-50 mix of dish soap and water solution and follow all connection instructions herein. Your propane dealer should be available for advice on the propane application and supply installation and should be able to answer questions.

This heater was designed and certified for use as a construction heater in accordance with ANSI Standard Z83.7b-2011/CSA STD 2.14b-2009. Check with your local fire safety authority if you have any questions about your applications. Other standards govern the use of fuel gases and heat producing products in specific applications. Your local authority can advise you about these.

This heater is Direct-Fired which means that all of the combustion products enter the heated space. Even though this heater operates very close to 100% combustion efficiency, it still produces small amounts of carbon monoxide. Carbon monoxide (called CO) is toxic. Humans can tolerate small amounts but not a lot. CO can build up in an enclosed heated space and failure to provide adequate ventilation could result in death. The symptoms of inadequate ventilation are:

• Headache • Dizziness • Burning Eyes and Nose • Nausea • Dry Mouth or Sore Throat • Difficulty in Breathing

Be sure to follow the advice about ventilation in these operating instructions.

Forced Air means that a blower or fan pushes the air through the heater.

Proper combustion depends upon proper air flow; therefore all openings of the heater must be left clear and free of obstructions. The heater must not be revised, modified or operated with parts removed or missing. Likewise, safety systems must not be circumvented or modified in order to operate the heater.

When the heater is to be operated in the presence of other people the user is responsible for properly acquainting those present with the safety precautions and instructions, and of the hazards involved in its use.

! WARNING

Page 6: Forced-Air Propane (LP) Gas Heatercomfortzone-us.com/temp/CZPP100_manual.pdf · Use only propane (LP) gas. 4. Use only VAPOR WITHDRAWAL propane (LP) supply. If there is any question

6

Model No. CZPP100CN | Model No. CZPP200CN

GE

NE

RA

L S

AF

ET

Y IN

ST

RU

CT

ION

S

Asphyxiation Hazard

• Do not use this heater for heating human living quarters.

• Do not use in unventilated areas.

• The flow of combustion and ventilation air must not be obstructed.

• Proper ventilation air must be provided to support the combustion air requirements of the heater being used.

• Refer to the specification section of the heater’s manual or heater dataplate to determine combustion air ventilation requirements of the heater.

• Lack of proper ventilation air will lead to improper combustion.

• Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptoms of carbon monoxide poisoning can include headache, dizziness, burning eyes and nose, nausea, dry mouth or sore throat and difficulty in breathing.

PROPANE (LP) FUEL GAS ODOR

Propane (LP) gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks. It can be described as a “rotten egg" smell. If a gas leak occurs you should be able to smell the fuel gas. Since propane (LP) is heavier than air you should smell for the gas odor low to the floor.

ANY GAS ODOR OR SMELL IS YOUR SIGNAL START IMMEDIATE ACTION!

• Do not take any action that could ignite the fuel gas. Do not operate any electrical switches. Do not pull any power supply or extension cords. Do not light matches or any other source of flame. Do not use your telephone.

• Get everyone out of the building and away from the area immediately.

• Close all propane (LP) gas tanks or cylinder fuel supply valves.

• Propane (LP) gas is heavier than air and may settle in low areas. When you have reason to suspect a propane leak, keep out of all low areas.

• While outside the building call your fuel gas supplier and your fire department. Do not re-enter the building or area in question.

• Stay out of the building and away from the area until declared safe by the firefighters and your fuel gas supplier.

• Be sure to have the fuel gas service person and the firefighters check for escaped gas. Have them air out the building and area before you return. Properly trained service people must repair any leaks, check for further leakages, and then have them relight the appliance for you.

PROPANE (LP) ODOR FADING - NO ODOR DETECTED

• Some people cannot smell well and cannot smell the odor of the man-made chemical added to propane (LP) or natural gas. You must determine if you can smell the odorant in these fuel gases.

• Learn to recognize the odor of propane (LP) gas and natural gas. It can be described as a “rotten egg” smell. The odorant can fade over time so leaking gas is not always detectable by smell alone. Local propane (LP) gas dealers will be more than happy to give you a scratch and sniff pamphlet. Use it to become familiar with the fuel gas odor.

• Smoking can decrease your ability to smell. Being around an odor for a period of time can affect your sensitivity to that particular odor. Odors present in animal confinement buildings can mask fuel gas odor.

• If there is an underground leak, the movement of gas through the soil can filter the odorant but the danger may still exist.

• Propane (LP) gas odor may differ in intensity at different levels. Since propane (LP) gas is heavier than air, there may be more odor at lower levels.

• Always be sensitive to the slightest gas odor. If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Take immediate action as discussed previously.

CRITICAL POINTS TO REMEMBER!

• Propane (LP) gas has a distinctive odor. Learn to recognize these odors. (Reference Propane (LP) Fuel Gas Odor and Propane (LP) Odor Fading sections above. Make all persons aware of the heaters use and to always be consciously aware of the odors of propane (LP) gas.

• If you have not been properly trained in the use and service of propane (LP) gas then do not attempt to light heater, perform service or repairs, or make any adjustments to the heater on the propane (LP) gas fuel system.

• A periodic sniff test around the heater or at the heater’s connections; i.e. hose to heater and hose/regulator to tank etc., is a good safety practice under all conditions. If you smell even a small amount of gas, CONTACT YOUR FUEL GAS SUPPLIER IMMEDIATELY. DO NOT WAIT!

! WARNING

Page 7: Forced-Air Propane (LP) Gas Heatercomfortzone-us.com/temp/CZPP100_manual.pdf · Use only propane (LP) gas. 4. Use only VAPOR WITHDRAWAL propane (LP) supply. If there is any question

7

Model No. CZPP100CN | Model No. CZPP200CN

VE

NT

ILA

TIO

NF

UE

L G

AS

ES

Be sure that the heater is only used with correct ventilation. Make sure that no object is obstructing the fan air intake. (Fig. 2)

OXYGEN DELETION:

The combustion of propane (LP) will consume a lot of oxygen. The minimum ventilation required by these heaters is 30cm³ per kW of heat output is strongly recommended. Never use the heater in an enclosed space.

CARBON MONOXIDE (CO) POISONING

Even though the direct-fired system of this heater operates very close to 100% combustion efficiency, it still generate small amounts of CO. Some people are more affected by CO than others. CO can build up in an enclosed space and failure to provide adequate ventilation could result in death. The symptoms of carbon monoxide poisoning can include headache, dizziness, burning eyes and nose, nausea, dry mouth or sore throat and difficulty in breathing.

Be sure to follow all advice about ventilation.

Fig. 1

Fig. 2

GUIDELINES OF FUEL GASES:

This heater is intended for the use of temporary heating of buildings under construction, alteration or remodeling. There may also be other local standards or regulations governing the use of fuel gases and heating products. You can get advice from your relevant local authority.

Propane and butane belong to the odorless fuel gases family. Normally gas suppliers will add an odor-making agent to help you detect a gas leakage. However, the odor added can fade over time. Fuel gases maybe present even though no odor exists.

This heater is intended for use with Propane (I3P). Any other fuel gas is considered misuse and dangerous.

To check the leakage of propane (LP) please use a professional gas leakage detector or simply with 50-50 mix of dish soap and water solution. Never check with a flame!

Propane (LP) is heavier than air. If there is a leakage, it sinks to the lowest possible level, collecting there with the surrounding air, forming a potentially explosive mixture. It is prohibited to use these gas heaters in high rise buildings, bedrooms, bathrooms, basements or below ground level.

! WARNING

Page 8: Forced-Air Propane (LP) Gas Heatercomfortzone-us.com/temp/CZPP100_manual.pdf · Use only propane (LP) gas. 4. Use only VAPOR WITHDRAWAL propane (LP) supply. If there is any question

8

Model No. CZPP100CN | Model No. CZPP200CN

OP

ER

AT

ION

AN

D U

SE

PREPARE HEATER FOR OPERATION

Check the heater, regulator, hose and POL fitting with o-ring thoroughly for damage. Do not use a damaged heater or hose assembly. Be sure the heating area is adequately ventilated, free of moisture and dust, far away from any combustible material as directed in this manual. Always put the propane (LP) gas cylinder behind the heater in a stable position. Never put the gas cylinder in front of the heater (Fig. 3)

IMPORTANT

User must locate heater at a safe distance from all combustible materials. (Fig. 4.), see specifications section for details. Use only supplied approved gas regulator and approved gas hose. Gas hose should be in its natural form without excessive bending and not twisted or kinked, ensure all connections are gas tight on regulator and hose.

When connecting to the gas cylinder, ensure the area is flame free to prevent risk of explosion.

Thread the POL fitting attached to the regulator of gas hose assembly to the propane (LP) cylinder valve. NOTE: The gas connection to the heater has a reverse left hand thread (threads counter-clockwise to tighten). Ensure the connection is gas tight.

Connect the other end gas hose to the heater at the rear of the unit Fig. 5 (C). Thread this connection clockwise to tighten. Ensure the connection is tight.

Check all connections with a professional gas leakage detector or with 50-50 mix of dish soap and water solution. Never check for leaks with a flame!

Do not adjust regulator in any way. Thread the gas hose assembly to the heater ensuring that the rubber hose is not twisted or kinked.

TO START THE HEATER (Fig. 5)

– Plug in the power to a wall grounded 120V AC, 60Hz wall socket.

CAUTION: Risk of electric shock. TO PREVENT ELECTRIC SHOCK; this appliance has a three prong grounded plug that must be inserted into a matching properly grounded outlet to reduce the risk of electrical shock. Do not defeat this safety feature.

– Press the ON/OFF switch (A) to ON position. Let the motor fan run at least 30 seconds to check if the fan works properly and/or to purge any fuel gas left from the last use.

– With the rubber hose attached to the gas inlet (C), open the gas valve on the propane (LP) cylinder slowly. Again, be sure there is no gas leakage.

Fig. 3

Fig. 4

Fig. 5

CBA D

! WARNING

! WARNING

! CAUTION

Page 9: Forced-Air Propane (LP) Gas Heatercomfortzone-us.com/temp/CZPP100_manual.pdf · Use only propane (LP) gas. 4. Use only VAPOR WITHDRAWAL propane (LP) supply. If there is any question

9

Model No. CZPP100CN | Model No. CZPP200CN

OP

ER

AT

ION

AN

D U

SE

SA

FE

TY

FE

AT

UR

ES

Fig. 6

– Push in and hold the safety start valve button (B). Push ignition button (D) repeatedly until the burner lights. If the heater does not light within 10 seconds, wait a minimum of 3 minutes before retrying.

– After the burner lights, keep the safety start valve button (B) pressed for at least 5 seconds to flow out any air and to heat up the safety valve then slowly release and the heater will continue to operate.

TO STOP HEATER USE (Fig. 6)

– To switch OFF the heater, always close the propane (LP) gas cylinder valve first.

– Let the motor fan run for at least 2 minutes until the heater has cooled down and the fuel has burned out of the heater.

– Switch off the motor (A)– If heater is not to be used again right away, remove gas hose from

propane (LP) cylinder, unplug the power cord.– If the heater will not be used again shortly, disconnect the gas hose

from the heater first, then disconnect the hose and regulator from the valve on the propane (LP) gas cylinder

CAUTION: Always shut off propane (LP) gas cylinder before disconnecting electrical power.

Be sure that the valve on the propane (LP) gas cylinder has been shut off firmly before disconnection. When changing the cylinder, be sure the surrounding area is flame and spark free. Should there be any gas leakage during operation, close the gas cylinder valve immediately, open all windows and doors, do not operate any equipment that may cause a spark (light switches, etc.) and inform the fire department as necessary.

IMPORTANT

After shut-down, allow 3-minutes before any restart.

Tip-Over

• The unit should be placed in an area that will not allow the heater to be tipped over. In case of accidental tip-over this unit is equipped with an internal tip-over switch that will shut the unit down immediately. The fan will continue to function.

• If the unit has tipped over, be observant of the area, confirm that there has not been any ignition of debris or objects in the area, even small ignitions can flame up under certain circumstances. If anything has ignited, move the heater and propane (LP) cylinder away from the area and extinguish the flame. Be careful, the heater surface may be hot.

• Inspect the heater for any damage. If any damage is present, discontinue use and contact Comfort Zone® for service.

• To resume the heater use, simply place the heater upright and turn switch (A) to OFF position. Wait 3 minutes. Restart the unit following the "TO START THE HEATER" instructions provided.

! WARNING

! CAUTION

Overheat Protection

• This heater is equipped with automatic overheat protection device. This device will shut the heater off if it becomes too hot inside. The flame will shut off and fan will continue to run.

• To reset the heater, simply turn power off and unplug the heater for 10 minutes until it cools down. You can plug in and restart the heater following the "TO START THE HEATER" instructions provided. Be sure the heater is on a smooth level surface with no obstructions.

Page 10: Forced-Air Propane (LP) Gas Heatercomfortzone-us.com/temp/CZPP100_manual.pdf · Use only propane (LP) gas. 4. Use only VAPOR WITHDRAWAL propane (LP) supply. If there is any question

10

Model No. CZPP100CN | Model No. CZPP200CN

Tab

le

of

Co

NT

eN

Ts

TR

OU

BL

ES

HO

OT

ING

Regular inspection and cleaning reduces the necessity for maintenance and will keep your heater in good working condition.

The motor must be correctly ventilated during the heater’s operation. For this reason avoid blocking the air inlets.

If the replacement of the supply cord is necessary, this has to be done by the manufacturer or an agent in order to avoid a safety hazard.

Remove the plug from the outlet when not in use and before making any adjustment, servicing or maintenance.

– Keep the heater clean, especially the motor grid and fan blades.– Store the heater in a dry, clean and safe place away from the reach of children.– The heater should be inspected at least once a year by a qualified person.– Check the gas hose and its screw connections frequently using a professional

gas leakage detector or simply with 50-50 mix of dish soap and water solution.– Repair can only be made by a suitably trained and qualified person.

Problem Cause Remedy

Fan Doesn’t WorkNo electricity Check power supply

Blade stalled by housing Repair/replace housing

Piezo Will Not Ignite

Ignition cable damaged Repair by a qualified person

Ignition cable disconnected Repair by a qualified person

Distance between electrode and burner too large

Adjust the distance to be within 3-8 mm.

No Gas

Gas cylinder is empty Replace with new gas cylinder

Gas valve on cylinder closed Open the valve

Gas valve of heater not open Attempt re-light sequence correctly

Flame Goes Out While Heater Running

Thermocouple-element was not heated enough

Repeat ignition process and keep safety gas valve depressed for a minimum of 5 seconds, then release slowly

Safety temperature control Allow the heater to cool down for at least 10 minutes. Check for obstructions and then attempt re-light sequence.

Restricted air-flow Check heater inlet & outlet, remove any obstructions

MA

INT

EN

AN

CE

AN

D S

TOR

AG

E

Page 11: Forced-Air Propane (LP) Gas Heatercomfortzone-us.com/temp/CZPP100_manual.pdf · Use only propane (LP) gas. 4. Use only VAPOR WITHDRAWAL propane (LP) supply. If there is any question

11

Model No. CZPP100CN | Model No. CZPP200CN

120V AC60Hz

Green

White

Black PowerSwitch

Tip-OverSwitch

SolenoidValve

ElectronicIgnitor

ThermocoupleAssembly

Thermal OverloadSwitch

Red

Black

Green

Black

Black

Black

BlackMotor

WIR

ING

DIA

GR

AM

WA

RR

AN

TY

LIMITED WARRANTY

Products manufactured by Comfort Zone® are warranted to the original consumer to be free of defects in material and workmanship for twelve (12) months from the original date of purchase. The warranty does not cover products modified outside our factory, damage or failure caused by acts of God, abuse, misuse, abnormal usage, faulty installation, failure to follow suggested maintenance procedures enclosed with this product (as defined by Magnuson-Moss Warranty-Federal Trade Commission Improvement Act) This unit is guaranteed to the original retail purchaser against defects in quality or workmanship for a period of one year from the date of original purchase. If this unit fails because of a manufacturing defect within 30 days of purchase, return the unit, with your receipt, to the retailer. After 30 days, but within the warranty period, if the unit was purchased within the continental united States, return it, freight prepaid, to Comfort Zone® for repair or replacement. If the unit was purchased outside the continental united States, return the unit to the place of purchase. This warranty does not cover damage caused by misuse, abuse, overheating and alteration. Repairs made by anyone other than Comfort Zone® are not covered in this warranty. Manufacturer will not be held liable for any losses due to neglectful operation. All implied warranties, including the warranties of merchantability and of fitness of purpose, if applicable, are hereby limited in duration to the period of one year from the date of original retail purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you. Incidental or consequential damages arising from a breach of either express or implied warranties are hereby disclaimed and excluded. Some states do not allow the exclusion of limitation of incidental or consequential damages, so this limitation or exclusion may not apply to you. Upon the expiration of this warranty all such liability will terminate. No other warranties are expressed or implied.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. No informal dispute settlement mechanisms are available. This limited warranty is given in lieu of all other warranties.

Manufactured for:Howard Berger Co. LLC324A Half Acre Rd.Cranbury, NJ 08512 USA800-221-6895www.comfortzone-us.com

Page 12: Forced-Air Propane (LP) Gas Heatercomfortzone-us.com/temp/CZPP100_manual.pdf · Use only propane (LP) gas. 4. Use only VAPOR WITHDRAWAL propane (LP) supply. If there is any question

Rev. #031215