PCV1030
FOR REPLACEMENT USE
Heat Pump 50 Hz
1
Quicker, easier installation of VRV III-Q for replacement use can be installed using existing refrigerant piping thanks to
its unique refrigerant control system with no special equipment or installation work
required. This enables renovation of the air conditioning system to be carried out quickly
and smoothly and minimises interference with operations and users in the building.
Introduction
QuickQuick QualityQualityThe concept
In the past, special equipment and work was needed to clean pipes when using existing piping, but this is no longer required. A new function automatically deals with dirt (contamination) inside piping during refrigerant charging, eliminating the work involved in cleaning.
Simple use of existing refrigerant piping.
The exact volume of refrigerant required, which can be difficult to assess for existing piping, is measured automatically. Charging from a gas cylinder with the exact volume necessary supports high-quality installation with fewer problems.
With just a single switch for test operation, refrigerant charging and removal of contamination (dirt inside piping) are carried out at the same time and the exact volume required is determined, simplifying the installation process.
Refrigerant charging completed with just one switch.
Automatic measurement of the exact volume necessary for refrigerant charging.
2
energy-saving air conditioning
Enables smooth replacement of air conditioning with less effect on operations and users in the building.
Reuse of existing refrigerant piping
Airtightness test
Vacuum drying
Conventional installation process for replacement of air conditioning
Refrigerant recovery and units removalRefrigerant recovery and units removal
Carry-in and installation of units
Airtightness test
Vacuum drying
Quicker installation
Quicker installation
1
2
3
4
5
6
7
8
1
2
3
4
5
Quicker and higher quality installation
Installation processfor replacement with
Replace
Replace Replace Replace
Removal of existing piping
Installation of new piping and wiring
Refrigerant charging and volume measurement
Test operation
Carry-in and installation of units
Automatic test operation
Reuse of existing piping
After replacement
Before replacement
Automatic refrigerant pipe cleaning
Automatic refrigerant charge
* For reuse of existing refrigerant piping, it is possible to use piping or branched piping capable of handling 3.3 Pa or more. Heat insulation is necessary for liquid piping and gas piping.
* It is possible to keep R-22 indoor units from K-series and later version. It is not possible to combine old R-22 and new R-410A indoor units in one system due to incompatibility of communication.
High COP
Benefits of system replacement
Design flexibility
3
Saves energy with high COP
Significantly more compact outdoor unit enables the effectiveuse of limited space!
1
Cooling operation (10 HP)
2
3
4
4.27
3.66
2.38 2.37
3005 mm750 mm
1240 mm765 mm
Compact design enables the effective use of space taken up by existing machinery
78.4 Pa
ConventionalVRV K PLUS series: RX(Y)16K(model from 14 years previous)16 HP outdoor unit
16 HP outdoor unit
58% Approx.
less space
High external static pressure 78.4 Pa
Installation space Installation space
2.25 m2
49.0 Pa 78.4 Pa
0.95 m2
Easier suction hood connection
(field setting)
We have reached a higher level of efficiency, thanks to advanced features such as the heat exchanger, the grille and the dual DC fans.
81% increase
Comparison of VRV III-Q and VRV K series
Small and light, significantly reducingconstraints during carry-in
Conventional VRV K series(model from 14 years previous)
External static pressure
Easy installation on each floor for use in tall buildings
Carry-in possible using ordinary elevators
Can be carried on a fork-lift without a pallet
Easy belt suspension
Approx.
54% increase
Approx.
• Cooling operating conditions: Indoor temp. of 27°CDB, 19.0 °CWB, and outdoor temp. of 35°CDB.
Conventional VRV K seriesRSX(Y)8, 10K
(model from 14 years previous)
Cooling operation (8 HP)
RQYQ8, 10P
: RQYQ16P
System flexibility
4
An increased number of connectable indoor units in a single system
Enables increased capacity
System can be upgraded using existing piping
More indoor units can be connected in a single system, enabling consolidation of existing piping!
Up to 64connectable
Before replacement10 HP
16 HP
After replacement
4.0 HP x 4 units
2.5 HP x 4 units
Where several systemsused to be required ...
Condensed intoa single system
Reuse of existing piping
The number of connectable indoor units has been drastically increased from 30 to 64.
VRV III-Q for replacement use enables the system capacity to be increased without changing the refrigerant piping. For example, it is possible to install a 16 HP VRV III-Q using the refrigerant piping of an 10 HP R-22 system.
indoor unitsUp to 30connectable
indoor units
ConventionalVRV K PLUS series: RX(Y)24–30K(model from 14 years previous)
Simple to deploy even in long, wide buildings with many small rooms
: RQYQ40–48P
Pipe size: 28.6, 12.7
Pipe size: 28.6, 12.7
* For reuse of existing refrigerant piping, it is possible to use piping or branched piping capable of handling 3.3 Pa or more. Heat insulation is necessary for liquid piping and gas piping.
Lineup
Outdoor unit combinations
System lineup for replacement use
5
Outdoor units
30, 32 HP26, 28 HP
42, 44 HP34, 36, 38, 40 HP 46, 48 HP
8, 10,12 HP 14, 16 HP 18, 20, 22, 24 HP
RQYQ8PY1RQYQ10PY1RQYQ12PY1
RQYQ18PY1RQYQ20PY1
RQYQ14PY1RQYQ16PY1
RQYQ22PY1RQYQ24PY1
RQYQ34PY1RQYQ36PY1
RQYQ42PY1RQYQ44PY1
RQYQ46PY1RQYQ48PY1
RQYQ38PY1RQYQ40PY1
RQYQ26PY1RQYQ28PY1
RQYQ30PY1RQYQ32PY1
Maximum number ofconnectable indoor units
Total capacity index of connectable indoor units*2 *3
Combination (%)
50% 100% 130%
HP Combination
RQYQ8PY1
RQYQ10PY1
RQYQ12PY1
RQYQ14PY1
RQYQ16PY1
RQYQ8PY1 + RQYQ10PY1
RQYQ8PY1 + RQYQ12PY1
RQYQ10PY1 + RQYQ12PY1
RQYQ12PY1 + RQYQ12PY1
RQYQ10PY1 + RQYQ16PY1
RQYQ12PY1 + RQYQ16PY1
RQYQ14PY1 + RQYQ16PY1
RQYQ16PY1 + RQYQ16PY1
RQYQ10PY1 + RQYQ10PY1 + RQYQ14PY1
RQYQ10PY1 + RQYQ10PY1 + RQYQ16PY1
RQYQ10PY1 + RQYQ12PY1 + RQYQ16PY1
RQYQ12PY1 + RQYQ12PY1 + RQYQ16PY1
RQYQ10PY1 + RQYQ16PY1 + RQYQ16PY1
RQYQ12PY1 + RQYQ16PY1 + RQYQ16PY1
RQYQ14PY1 + RQYQ16PY1 + RQYQ16PY1
RQYQ16PY1 + RQYQ16PY1 + RQYQ16PY1
260
325
390
455
520
585
650
715
780
845
910
975
1,040
1,105
1,170
1,235
1,300
1,365
1,430
1,495
1,560
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1,000
1,050
1,100
1,150
1,200
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
525
550
575
600
Model name
RQYQ8PY1
RQYQ10PY1
RQYQ12PY1
RQYQ14PY1
RQYQ16PY1
RQYQ18PY1
RQYQ20PY1
RQYQ22PY1
RQYQ24PY1
RQYQ26PY1
RQYQ28PY1
RQYQ30PY1
RQYQ32PY1
RQYQ34PY1
RQYQ36PY1
RQYQ38PY1
RQYQ40PY1
RQYQ42PY1
RQYQ44PY1
RQYQ46PY1
RQYQ48PY1
8 HP
10 HP
12 HP
14 HP
16 HP
18 HP
20 HP
22 HP
24 HP
26 HP
28 HP
30 HP
32 HP
34 HP
36 HP
38 HP
40 HP
42 HP
44 HP
46 HP
48 HP
13
16
19
22
26
29
32
35
39
42
45
48
52
55
58
61
64
Outdoor unit multi connection piping kit*1
–
–
–
–
–
BHFP22P100
BHFP22P151
Capacityindex
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1,000
1,050
1,100
1,150
1,200
*1 For multiple connections of 18 HP systems and above, the outdoor unit multi connection piping kit (separately sold) is required.*2 Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor units.*3 When outdoor-air processing units and standard indoor units are connected, the total connection capacity of the outdoor-air processing units must not exceed 30%
of the capacity index of the outdoor units.
System lineup for replacement use
6
Indoor units
FXFQ25/32/40/50/63/80/100/125PVE FXZQ20/25/32/40/50MVE
FXDQ20/25/32PBVE(T) FXDQ40/50/63NBVE(T)
FXMQ20/25/32/40/50/63/80/100/125/140PVE
FXMQ200/250MAVEFXHQ32/63/100MAVE
FXCQ20/25/32/40/50/63/80/125MVE
FXKQ25/32/40/63MAVE
Connection unit seriesFloor Standing Concealed Floor Standing
Ceiling Mounted Cassette Corner
Ceiling Mounted Duct
Ceiling Suspended Cassette
Ceiling Mounted Cassette(Round Flow)
Ceiling Suspended Wall Mounted
Ceiling Mounted Cassette(Double Flow)
900/1,100 mm width type–with drain pump–without drain pump
Slim Ceiling Mounted Duct700 mm width type–with drain pump–without drain pump
Ceiling Mounted Cassette(Compact Multi Flow)
Air treatment equipment
Outdoor-Air Processing Unit HRV with DX-Coil and Humidifier Heat Reclaim Ventilation
* It is possible to keep R-22 indoor units from K-series and later version. It is not possible to combine old R-22 and new R-410A indoor units in one
system due to incompatibility of communication.
FXAQ20/25/32/40/50/63MAVE
FXMQ125/200/250MFV1 VKM50/80/100GA(M)V1VAM150/250/350/500/650/800/1000/1500/2000GJVE
FXLQ20/25/32/40/50/63MAVE FXNQ20/25/32/40/50/63MAVE FXUQ71/100/125MAV1Connection unitBEVQ71/100/125/MAVE
Guidelines for reuse of existing refrigerant piping
p
q
k
First outdoor branch
fa
b
Firstindoor branch
Multiple use
*The rest of indoor units are the same as for single use.
a
i
s
r
hgf
edcbFirst indoor branch
Single use
Colours in the diagram above are merely for identifying pipes referenced with symbols such as a .
*1 Piping between REFNETs depends on total capacity index of indoor units connected below each REFNET. It cannot exceed piping size of upstream side.*2 Piping from REFNET to indoor unit depends on the capacity of the connected indoor unit. It cannot exceed piping size of upstream side.
Maximumallowablelevel difference
Maximumallowablepiping length
Between the outdoor unitsand the indoor units
Between the indoor units
Between the outdoor units (Multiple use)
Between the first indoor branch and the farthest indoor unit
Between the outdoor branch and the last outdoor unit
Total piping length
Refrigerant piping length
15 m
5 m
—
—
q
s
a+b+c+d+e+f+g+h+i
a+f+g+h+i
f+g+h+i
k+p
150 m 175 m
300 m
40 m
10 m 13 m
Actualpiping length
Equivalentpiping length Example
Level Difference Example
50 m rIf the outdoor unit is above.
If the outdoor unit is below. 40 m r
Reusability of existing piping for VRVIII-Q
Piping limits for reuse of existing piping
8 HP10 HP12 HP14 HP16 HP18 HP20 HP22 HP24 HP26 HP28 HP30 HP32 HP34 HP36 HP38 HP40 HP42 HP44 HP46 HP48 HP
< 100100 ≤ X < 150150 ≤ X < 160160 ≤ X < 200200 ≤ X < 290290 ≤ X < 330330 ≤ X < 420420 ≤ X < 480480 ≤ X < 640640 ≤ X < 900900 ≤ X < 920920 ≤ 20–40 class
50 class63 class80 class
100–125 class140 class200 class250 class
: Piping size of conventional R-22 model: Piping size of conventional R-410A model: Standard piping size of VRVIII-Q
: Possible: Standard piping size of VRV III-Q. However, when equivalent piping length between outdoor unit and indoor unit is 90 m or more, size of main piping must be increased.: Not possible
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
7
6.4 9.5 12.7 15.9Liquid
Piping sizeGas
19.1 22.2 12.7 15.9 19.1 22.2 25.4 28.6 34.9 41.3 54.1
Type of piping
Main piping
From REFNETto REFNET *1
From REFNETto indoor unit*2
Capacity
Specifications
Outdoor units
15.9 (Brazing)
28.6 (Brazing)
12.7 (Brazing)
28.6 (Brazing)
8
Heat Pump
Heating capacitykW
Btu/h
kcal/h
Power supply
R-410A
–5 to 43
Hermetically sealed scroll type
Ivory white (5Y7.5/1)
3-phase 4-wire system, 380–415 V, 50 Hz
90.6
19.1 (Brazing)
34.9 (Brazing)
63
381+381
100
5-100
90.0
Power supply 3-phase 4-wire system, 380–415 V, 50 Hz
R-410A
((2.7+4.5+4.5)X1)+((2.7+4.5+4.5)X1)
78,000
310,000
86,000
341,000
Hermetically sealed scroll type
Ivory white (5Y7.5/1)
233+233
11.7+11.7
15.9 (Brazing)
28.6 (Brazing)
62
230+284
62.5
56.2
15.9 (Brazing)
28.6 (Brazing)
63
284+284
69.0
61.9
15.9 (Brazing)
34.9 (Brazing)
63
284+284
75.0
67.4
19.1 (Brazing)
34.9 (Brazing)
63
284+381
81.5
73.5
19.1 (Brazing)
34.9 (Brazing)
63
284+381
87.5
79.0
19.1 (Brazing)
34.9 (Brazing)
63
381+381
95.0
85.5
(1,680X1,240X765)+(1,680X1,240X765)(1,680X930X765)+(1,680X1,240X765)
8-100 7-100 6-100 6-100 5-100 5-100
55.9 61.5 67.0 73.0 78.5 85.0
((1.4+4.5)X1)+((3.3+4.5)X1)
((3.3+4.5)X1)+((3.3+4.5)X1)
((1.4+4.5)X1)+((2.7+4.5+4.5)X1)
((3.3+4.5)X1)+((2.7+4.5+4.5)X1)
((1.6+4.5+4.5)X1)+((2.7+4.5+4.5)X1)
48,300
192,000
53,200
211,000
58,000
230,000
63,300
251,000
67,900
270,000
73,500
292,000
53,800
213,000
59,300
235,000
64,500
256,000
70,100
278,000
75,300
299,000
81,700
324,000
180+200 185+200 200+200 185+233 200+233 233+233
10.8+11.7 11.7+11.7 11.7+11.7 11.7+11.711.7+11.7 11.7+11.7
Power consumptionCooling (*2)
HeatingkW
15.4
16.7
17.8
18.8
20.2
20.4
21.3
22.2
23.7
23.8
25.2
25.8
27.2
27.2
4.5X1 (1.4+4.5)X1
10.8 11.7
230 284
57 58
1,680X930X765
180 185
284
60
200
20-100 14-100
25.0
85,300
21,500
31.5
107,000
27,100
22.5
76,800
19,400
28.2
96,200
24,300
(1.6+4.5+4.5)X1
381
60
233
22.4 28.0
14-100
37.5
128,000
32,300
33.7
115,000
29,000
33.5
10-100
45.0
154,000
38,700
40.2
137,000
34,600
40.0
11.7 11.7
(3.3+4.5)X1
1,680X1,240X765
9.5 (Brazing)
19.1 (Brazing)
9.5 (Brazing)
22.2 (Brazing)
12.7 (Brazing)
28.6 (Brazing)
12.7 (Brazing)
28.6 (Brazing)
5.24
6.42
7.64
8.59
10.1
10.2
11.6
12.2
RQYQ8PY1 RQYQ10PY1 RQYQ12PY1 RQYQ14PY1
(2.7+4.5+4.5)X1
381
60
233
10-100
50.0
171,000
43,000
45.3
155,000
39,000
45.0
11.7
13.6
13.6
RQYQ16PY1MODEL
MODEL Combination units
RQYQ20PY1 RQYQ22PY1
RQYQ8PY1RQYQ12PY1
(1,680X930X765)+(1,680X930X765)
61
230+284
56.5
50.7
9-100
50.4
(4.5X1)+((1.4+4.5)X1)
(4.5X1)+((3.3+4.5)X1)
43,600
173,000
48,600
193,000
180+185
10.8+11.7
12.9
15.1
RQYQ18PY1
RQYQ8PY1RQYQ10PY1
RQYQ10PY1RQYQ12PY1
RQYQ24PY1 RQYQ26PY1
RQYQ12PY1RQYQ12PY1
RQYQ10PY1RQYQ16PY1
RQYQ28PY1 RQYQ30PY1
RQYQ12PY1RQYQ16PY1
RQYQ14PY1RQYQ16PY1
RQYQ32PY1
RQYQ16PY1RQYQ16PY1
Cooling capacity (*1)(*2) Btu/h(*1)
(*1)kW
(*2)
kcal/h(*1)
Refrigerant
Machine weight kg
dB(A)
Dimensions (HXWXD) mm
m3/min
Capacity control
Compressor
Sound level
°CDB
–20 to 15.5°CWBOperation range
–5 to 43
–20 to 15.5
%
Airflow rate
Casing colour
Pipingconnections
Motor output kW
Type
Type
Liquid
Gasmm
Heating capacitykW
Btu/h
kcal/h
Power consumptionCooling (*2)
HeatingkW
Cooling capacity (*1)(*2) Btu/h(*1)
(*1)kW
(*2)
kcal/h(*1)
Capacity control
Compressor
%
Casing colour
Motor output kW
Type
Refrigerant
Machine weight kg
dB(A)
Dimensions (HXWXD) mm
m3/min
Sound level
Airflow rate
Pipingconnections
Charge kg
Type
Liquid
Gasmm
Cooling
Heating
Charge kg
°CDB
°CWBOperation range
Cooling
Heating
•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB. (*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.•Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.•Equivalent piping length: 7.5 m•Level difference: 0 m
9
•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Heat Pump
19.1 (Brazing)
34.9 (Brazing)
136
19.1 (Brazing)
41.3 (Brazing)
65
381+381+381
150
3-100
135
Power supply 3-phase 4-wire system, 380–415 V, 50 Hz
R-410A
((2.7+4.5+4.5)X1)+((2.7+4.5+4.5)X1)+((2.7+4.5+4.5)X1)
117,000
464,000
129,000
521,000
Hermetically sealed scroll type
Ivory white (5Y7.5/1)
233+233+233
11.7+11.7+11.7
19.1 (Brazing)
41.3 (Brazing)
64
284+284+381
113
102
19.1 (Brazing)
41.3 (Brazing)
65
284+284+381
119
108
19.1 (Brazing)
41.3 (Brazing)
65
284+284+381
125
113
19.1 (Brazing)
41.3 (Brazing)
65
284+381+381
132
119
19.1 (Brazing)
41.3 (Brazing)
65
284+381+381
138
125
19.1 (Brazing)
41.3 (Brazing)
65
381+381+381
145
131
(1,680X1,240X765)+(1,680X1,240X765)+(1,680X1,240X765)
(1,680X930X765)+(1,680X1,240X765)+(1,680X1,240X765)
4-100 4-100 4-100 4-100 4-100 3-100
101 107 112 118 124 130
((1.4+4.5)X1)+((3.3+4.5)X1)+
((2.7+4.5+4.5)X1)
((3.3+4.5)X1)+((3.3+4.5)X1)+
((2.7+4.5+4.5)X1)
((1.4+4.5)X1)+((2.7+4.5+4.5)X1)+((2.7+4.5+4.5)X1)
((3.3+4.5)X1)+((2.7+4.5+4.5)X1)+((2.7+4.5+4.5)X1)
((1.6+4.5+4.5)X1)+((2.7+4.5+4.5)X1)+((2.7+4.5+4.5)X1)
87,700
348,000
92,900
368,000
97,200
386,000
102,000
406,000
108,000
427,000
113,000
447,000
97,200
386,000
102,000
406,000
108,000
427,000
114,000
450,000
119,000
471,000
125,000
495,000
185+185+233 185+200+233 200+200+233 185+233+233 200+233+233 233+233+233
11.7+11.7+11.7 11.7+11.7+11.7 11.7+11.7+11.7 11.7+11.7+11.711.7+11.7+11.7 11.7+11.7+11.7
28.9
30.8
31.4
32.4
33.8
34.0
34.9
35.8
35.3
36.0
38.8
39.4
40.8
40.8
MODELCombination units
RQYQ36PY1 RQYQ38PY1
RQYQ10PY1RQYQ10PY1RQYQ16PY1
(1,680X930X765)+(1,680X930X765)+(1,680X1,240X765)
64
284+284+381
108
96.6
5-100
96.0
((1.4+4.5)X1)+((1.4+4.5)X1)+
((1.6+4.5+4.5)X1)
((1.4+4.5)X1)+((1.4+4.5)X1)+
((2.7+4.5+4.5)X1)
83,200
329,000
92,700
368,000
185+185+233
11.7+11.7+11.7
26.9
29.4
RQYQ34PY1
RQYQ10PY1RQYQ10PY1RQYQ14PY1
RQYQ10PY1RQYQ12PY1RQYQ16PY1
RQYQ40PY1 RQYQ42PY1
RQYQ12PY1RQYQ12PY1RQYQ16PY1
RQYQ10PY1RQYQ16PY1RQYQ16PY1
RQYQ44PY1 RQYQ46PY1
RQYQ12PY1RQYQ16PY1RQYQ16PY1
RQYQ14PY1RQYQ16PY1RQYQ16PY1
RQYQ48PY1
RQYQ16PY1RQYQ16PY1RQYQ16PY1
–5 to 43
–20 to 15.5
Heating capacitykW
Btu/h
kcal/h
Power consumptionCooling (*2)
HeatingkW
Cooling capacity (*1)(*2) Btu/h(*1)
(*1)kW
(*2)
kcal/h(*1)
Capacity control
Compressor
%
Casing colour
Motor output kW
Type
Refrigerant
Machine weight kg
dB(A)
Dimensions (HXWXD) mm
m3/min
Sound level
Airflow rate
Pipingconnections
Charge kg
Type
Liquid
Gasmm
°CDB
°CWBOperation range
Cooling
Heating
Specifications
Outdoor units
Note: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor temp. of 35.0°CDB. (*2) Indoor temp. of 27°CDB, 19.0°CWB, and outdoor temp. of 35.0°CDB.•Heating: Indoor temp. of 20°CDB, and outdoor temp. of 7°CDB, 6°CWB.•Equivalent piping length: 7.5 m•Level difference: 0 m
10
Option List
Outdoor units
Control Systems
No.
1 Cool/Heat Selector
4
3
1-1 Fixing box
REFNET joint
5 Central drain pan kit
Pipe size reducer
REFNET header2
Outdoor unit multi connection piping kit
Distributivepiping
KJB111A
KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73T
KHRP26M73TP, KHRP26M73HP
RQYQ24PY1RQYQ26PY1RQYQ28PY1
RQYQ30PY1RQYQ32PY1
KWC26C280X2 KWC26C450X2
BHFP22P100 BHFP22P151
6 Digital pressure gauge kit BHGP26A1X2 BHGP26A1X3
RQYQ34PY1RQYQ36PY1RQYQ38PY1RQYQ40PY1
RQYQ42PY1RQYQ44PY1
RQYQ46PY1RQYQ48PY1
KWC26C280X2KWC26C450
KWC26C280KWC26C450
KWC26C280KWC26C450X2
KWC26C450X3
KRC19–26A
KHRP26M22H (Max. 4 branch), KHRP26M33H (Max. 8 branch)KHRP26M72H (Max. 8 branch), KHRP26M73H (Max. 8 branch)
Type
Item
No.
1 Cool/Heat Selector KRC19–26A
1-1 Fixing box
2REFNET header
REFNET joint
3
KHRP26M22H (Max. 4 branch)KHRP26M33H (Max. 8 branch)
KHRP26M22H (Max. 4 branch), KHRP26M33H (Max. 8 branch)KHRP26M72H (Max. 8 branch)
KHRP26A22T, KHRP26A33T
Outdoor unit multi connection piping kit
RQYQ8PY1RQYQ10PY1RQYQ12PY1
RQYQ14PY1RQYQ16PY1
RQYQ18PY1RQYQ20PY1RQYQ22PY1
— BHFP22P100
KJB111A
KHRP26A22T, KHRP26A33T, KHRP26A72T
—
4 Central drain pan kit KWC26C450 KWC26C280X2KWC26C280
5 Digital pressure gauge kit BHGP26A1 BHGP26A1X2
Distributivepiping
Type
Item
Building Management System
Notes: *1. BACnet® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
*2. LONWORKS® is a registered trade mark of Echelon Corporation. *3. Installation box for adaptor must be obtained locally.
•Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-conditioning systems through LONWORKS® communication.DMS504B514
3
•Expansion kit, installed on DMS502B51, to provide 2 more DIII-NET communication ports. Not usable independently.DAM411B513-1
•Enables ON/OFF command, operation and display of malfunction; can be used in combination with up to 4 units.DPF201A515
•Enables temperature measurement output for 4 groups; 0-5VDC.DPF201A526
•Enables temperature setting input for 16 groups; 0-5VDC.DPF201A537
No. Item Model No. Function
*2 Interface for use in LONWORKS®
•Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-conditioning systems through BACnet® communication.DMS502B51*1 Interface for use in BACnet®
Optional DIII board
Con
tact
/ana
logu
esi
gnal
Parallel interfaceBasic unit
Temperaturemeasurement units
Temperaturesetting units
•Air conditioner management system that can be controlled by personal computers.
DAM602B51
KJB411AA
DAM602B52
256 units
DAM602B51x2512 units
DAM602B51x3768 units
DAM602B51x41024 unitsintelligent Manager III
128 units
2Number of units to be connected
HardwareBasic
•Expansion kit, installed on DMS502B51, to provide 16 more wattmeter pulse input points. Not usable independently.
•External temperature sensor for intelligent Manager III.
DAM412B51
DAM101A51
Optional Di board
Optional DIII Ai unit2-4
•8 pairs based on a pair of On/Off input and abnormality input.DEC101A51Di unit2-5
3-2
1-1
1-4
1
Electrical box with earth terminal (4 blocks)
DCS601A521-1 •Additional 64 groups (10 outdoor units) is possible.
DCS004A511-3 •Monitors and controls the air conditioning system using the Internet and a Web browser application on a PC.
•Wall embedded switch box.
DCS601C51 •Air-Conditioning management system that can be controlled by a compact all-in-one unit.
Com
mun
icat
ion
line
DCS002C511-2
intelligent Touch
Controller
DIII-NET plus adaptor
Web
intelligent Touch Controller
PPD
Hardware
Hardware
Software
Basic
Option •PPD: Power Proportional Distribution function
•4 pairs based on a pair of On/Off input and abnormality input.DEC102A51Dio unit2-6
2-1
2-2
2-3
•Power Proportional Distribution functionDAM002A51
Option Software
2-1
•Monitors and controls the air conditioning system using the Internet and a Web browser application on a PC.DAM004A512-2
•ECONO (Energy saving functions.)DAM003A51
PPD
Web
ECONO2-3
•Interface between the central monitoring board and central control units.DCS302A528 Unification adaptor forcomputerised control
Air Conditioning Network Service System (Optional Maintenance Service) is also available.
All rights reservedPrinted in Japan 08/10/005 Y.K.c
DealerHead Office:Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:JR Shinagawa East Bldg., 2-18-1, Konan,Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global_ac/
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Cautions on product corrosion
Warning Daikin Industries, Ltd.’s products are manufactured for export to numerous countries throughout the world. Daikin Industries, Ltd. does not have control over which products are exported to and used in a particular country. Prior to purchase, please therefore confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Specifications, designs and other content appearing in this brochure are current as of August 2010 but subject to change without notice.
JMI-0107 JQA-1452
Organization:DAIKIN INDUSTRIES, LTD.AIR CONDITIONING MANUFACTURING DIVISION
Scope of Registration:THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, COMMERCIAL HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, MARINE TYPE CONTAINER REFRIGERATION UNITS, COMPRESSORS AND VALVES.
Organization:DAIKIN INDUSTRIES(THAILAND) LTD.
Scope of Registration:THE DESIGN/DEVELOPMENTAND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM
All of the Daikin Group’s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management.