For Mass, Volume, Viscosity,and Moisture Content Management

Micro Analytical Balances

BM SeriesFor sample preparation in elemental analysis/mass spectrometry, measurement of environmental pollutants, pharmaceuticals, food additives, etc.

Interlockable sliding doorssible to slide door open usinghandle on the opposite side

Neutralizing chamber

Separation plate

Weighing chamber

1 ........

e green LED is lit while theizer is on.

n Minimum weighing value from 1 µg (1/1,000,000 of 1 g)

n Smooth, instantaneous elimination of static using a built-in fanless ionizer to ensure stable weighing

n Expert assessment of the installation environment using the AND-MEET* available

Weighing capacity: 22 g to 520 gMin. weighing value: 1 µg to 0.1 mg

* Patent pending

A&D Measurement Environment Evaluation Tool (AND-MEET)

Graph 1. Temperature, zero point and span value changes over 24 hours Graph 2. Temperature and repeatability changes over 24 hours

troller2A

Micro Analytical Balances

BM Series

........ 2

Tabletop Breeze Break

AD-1672An Shields a highly sensitive analytical balance from air and

temperature disturbances caused by air conditioning, people passing by, or the operators themselves

Anti-vibration table for balances

AD-1671n Isolates a highly sensitive analytical balance from minute

vibrations that seriously affect the stability of weighing

Standard accessoriesStandard accessories

Weighing Data Logger

AD-1688

CarrySave and Retrieve the Data!

n Stores up to 5,000 weighing results with time and date

Special pans/holder (for the BM-20/22)

Slide Breeze Break (for the BM-20/22)

Aluminum analytical pansø8 mm (0.05 ml) / ø12 mm (0.3 ml) /ø15 mm (0.8 ml)

Weighing pans for PM filtersø50 mm / ø95 mm

Microcentrifugetube holder

n Reduces the effects of drafts and convection flows inside the weighing chamber for stable weighing

Weighing Environment Logger

AD-1687For managing environmental and weighing data with just one device

3 ........

Weighing Environment Logger

AD-1687

For constant monitoring of the wind speed of a containment enclosure, managing the environmental factors that affect the stability of a microbalance, etc.

Air Flow Logger

AD-1641

n Simultaneously logs temperature, humidity, barometricpressure, and vibration with weighing data from a balance/scale

n Large memory capacity of 10,000 data sets

n Instant data saving to a PC requiring no special software

n Precisely captures low-velocity air flows of 0 to 1.00 m/s - together with temperature, humidity, barometric pressure and vibration

n Alarm for abnormal values (comparator function)

Sensor

Temperature

Humidity

Barometric pressure

Vibration

Resolution

0.1 ºC

0.1 ºF

0.1% RH

0.1 hPa

1 mG (gal)

Measurement range

0 to 60 ºC

32 to 140 ºF

0 to 100% RH

500 to 1100 hPa

0 to 2000 mG (gal)

Accuracy

±0.5 ºC (20 to 30 ºC)

±0.9 ºF (68 to 86 ºF)

±3% (20 to 80%)

±3 hPa (0 to 60 ºC)

±20 %, static acceleration

Endorectal probe for mice (AX-KO4746-100) Endorectal probe for rats (AX-KO4747-100)

AD-1687 as an Animal Body Temperature Logger

Air Flow Logger

AD-1641

Weighing Environment Analyzer

AD-1691For SOP-based management of balance quality and performance

Weighing Environment Analyzer

AD-1691n Easy operation by following step-by-step guidance

on a color touch-panel screen

n Daily balance check to confirm that the balance meets proper conditions for use

n Periodic balance check including tests for repeatability, accuracy/linearity, and eccentricity error

n Uncertainty calculation of balance calibration based on seven uncertainty componentsn Minimum weight calculation according to the United States Pharmacopeia (USP) standard

Documentation of results

n Assessment of measurement environment using the AND-MEET with the BM seriesn Remote balance display and control

Daily balance check Periodic balance check

Uncertainty calculation Minimum weight calculation

Daily check report (PDF) Periodic check report (PDF) Calibration report (PDF)........ 4

Micro Analytical Weighing Sensors

AD-4212D Series

Mass Comparators

MC Series

5 ........

Mass Comparators

MC Series

n Stabilizing filter to minimize errors due to drafts or vibrations

n Auto-centering pan that automatically corrects eccentric loadings available for MC-1000/6100/10K/30K

For measurements of fine weight changes with heavy tare weights, such as fill level of gas, in addition to use as mass comparators

Micro Analytical Weighing Sensors

AD-4212D Series

n Easily withstands the vacuum state during gas displacement as the sensor is independent of display

n Compact and ideal for installation in narrow spaces

n Comes standard with the AD-1691 weighing environment analyzer

For analytical weighing inside glove boxes, fume hoods, etc.

n Detects the presence of static electricity, which is often the cause of unstable weighing

Static Eliminator

AD-1683n Instantly neutralizes charged objects

to ensure stable weighing

Weighing capacity: 32 g to 320 gMin. weighing value: 1 µg to 10 µg

Weighing capacity: 1100 g to 101 kgMin. weighing value: 0.0001 g to 0.1 g

10cm 20cm 30cm 50cm

Effective area forneutralization

Ionizationarea

Distribution of ion production

Ionizationarea

Electrostatic Field Meter

AD-1684A

Tuning Fork Vibro Rheometer

RV-10000AFor easy characterization of non-Newtonian fluids

Tuning Fork Vibro Rheometer

RV-10000An Quick stability (20 seconds) and high repeatability

(1% of the measured value by the standard deviation) with low viscosity fluids

n Automatic shear rate changes (by altering the amplitude) and data graphing

n Minimum interference to the sample and its physical structure

n Easy maintenance and calibration

n Accurate, concurrent measurements of temperature and viscosity

n Wide continuous measurement range (max. 0.3 to 25,000 mPa s)

Example: Measurement of skin moisturizing cream

........ 6

Water jacket Temperaturecontrol tank

Measurable viscosity range

0.07 mm ≤ amplitude < 0.1 mm

0.1 mm ≤ amplitude < 0.2 mm

Amplitude = 0.2 mm

0.2 mm < amplitude ≤ 0.4 mm

0.4 mm < amplitude ≤ 0.8 mm

0.8 mm < amplitude ≤ 1.2 mm

2,000 to 25,000 mPa•s

20 to 25,000 mPa•s

0.3 to 25,000 mPa•s

0.3 to 12,000 mPa•s

0.3 to 5,000 mPa•s

0.3 to 3,000 mPa•s

Also possible to control the sample temperature using a commercially available temperature control tank

Tuning Fork Vibro Viscometers

SV-AFor quick and repeatable measurements from very low to high viscosity

Tuning Fork Vibro Viscometers

SV-A Series

Measurement range: 0.3 to 10,000 mPa·s / 1 to 100 Pa·s

Moisture Analyzers

MS-70/MX-50/MF-50/ML-50For highly reliable measurement of moisture content that is safe, rapid and easy to perform

Moisture Analyzers

MS-70/MX-50/MF-50/ML-50

Min. reading for weight: From 0.1 mgMin. reading for moisture content: From 0.001%

Cloud point measurement of detergent

7 ........

n Low moisture content measurement at 10 ppm (0.001%) resolution (MS-70)

n Fast and uniform heating with halogen lamp and innovative Secondary Radiation Assist (SRA) technology

n Accuracy verification with Sodium Tartrate Dihydrate (standard with MS-70, MX-50 and MF-50)

n Simultaneous, real-time measurement and graphing of temperature and viscosity changesn Required sample quantity from as small as 2 ml (SV-1A)

........ 8

Single Channel Electronic Pipettes

MPA SeriesFor accurate, efficient pipetting with minimal stress on hands

Single Channel Electronic Pipettes

MPA Series

n Automatic control ensuring accuracy for everyone at all timesn Stress-minimized, pain-free operation using the forefingern Various useful pipetting functions, including multiple dispensing

and mixing

n Easy calibration and adjustment, either by volume (µL/mL) or weight (mg)*

n Increased resistance to impacts from falls from padding on the four corners of the head*

n Displays moisture rate changes over time in a graph (RsFig)n Quickly and automatically suggests the most suitable heating conditions for first-time

samples (RsTemp)

Special Software "WinCT-Moisture" (Standard with MS-70 and MX-50)

RsFig (Corn starch) RsTemp (Soybean flour)

Operation(plunger) key

Multiple dispensing into a microplate Mixing

* Patent pending

Impact-absorbing pads

Pipette Accuracy Testers

AD-4212B-PT/AD-4212A-PTFX-300i-PTFor in-house management and recording of pipette accuracy

Pipette Accuracy Testers

AD-4212B-PT/AD-4212A-PTFX-300i-PT

BMSeries + BM-014

n Automatic mass-to-volume conversion and judgments for accuracy and repeatability using the special "WinCT-Pipette" software

n Judgments by your preferred criteria - manufacturer specifications, ISO8655, or in-house specifications

n Outputs the test results in an A4 or letter-size report format for documentation requirements

n Evaporation trap to minimize errors due to evaporation

The BM-014 can be used with any model of the BM series.

Also available...WinCT-Pipette

9 ........

Min. weighing value: From 1 µgNominal volume of the pipette to be tested: From 1 µL

Micro Analytical Balances Pipette Accuracy Testing Kit

Pipette Professional

AD-1695

Leak Tester

AD-1690For quick screening for pipette failure

Leak Tester

AD-1690

For SOP-based management of pipette quality and performance

Pipette Professional

AD-1695

n Takes only seconds to tell whether a pipette hasa leak

n Changes pressure by evacuating air instead of injecting it, so that no dust enters the pipette being tested

n Easy operation by following step-by-step guidance on a color touch-panel screen

n Daily pipette check to confirm that the pipette meets proper conditions for use

n Periodic pipette check for pipette volume accuracy and repeatability

Daily pipette check Periodic pipette check

Depressurization value: −20 kPa ± 20%

Daily check report (PDF) Periodic check report (PDF)

Documentation of results

........ 10

*Lab Solutions-ADCC-01-PR1-16302

...Clearly a Better Value

Vereyskaya str.17, Moscow, 121357 RUSSIATelephone: [7] (495) 937-33-44 Fax: [7] (495) 937-55-66

509 Udyog Vihar Phase VGurgaon-122 016, Haryana, INDIATelephone: [91](124) 471-5555 Fax: [91](124) 471-5599

A&D InstD Instruments India Pruments India Private e Limitedmited

3-23-14 Higashi-lkebukuro, Toshima-ku,Tokyo 170-0013 JAPANTelephone:[81](3) 5391-6132 Fax:[81](3) 5391-6148http://www.aandd.jp

Unit 24/26 Blacklands Way Abingdon Business Park, Abingdon, Oxon OX14 1DY UNITED KINGDOMTelephone:[44](1235) 550420 Fax:[44](1235) 550485

1756 Automation Parkway, San Jose, CA 95131 U.S.A.Telephone:[1](408) 263-5333 Fax:[1](408) 263-0119

A&D Australasia ia Pty y Ltd.d.32 Dew Street, Thebarton, South Australia 5031 AUSTRALIATelephone:[61](8) 8301-8100 Fax:[61](8) 8352-7409

<German Sales Office>Hamburger Straße 30 D-22926 Ahrensburg GERMANYTelephone:[49](0) 4102 459230 Fax:[49](0) 4102 459231

817, Manhattan Bldg., 33, Gukjegeumyung-ro 6-gil,Yeongdeungpo-gu, Seoul, 07331, KOREATelephone:[82](2) 780-4101 Fax:[82](2) 782-4280