Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
PROPERTY FEATURES
+ Total building is 100,497 square feet
+ Suite C-1 - 6,208 square feet available
− Suite includes three hard-walled offices, a break room, large conference room, a clean room, lab space and open office area
− Two dock-high doors
+ Suite C-2 - 7,387 square feet available
− Approximately 50% office buildout
− Drop ceiling throughout
− Two dock-high doors
+ Suite D - 5,000 square feet available
− 100% office buildout
− Two dock-high doors
+ Suite E - 5,000 square feet available
− 100% office buildout
− Two dock-high doors
+ Suite F - 5,000 square feet available
− 100% office buildout with some lab space
− Two dock-high doors
+ Potential to combine Suites C-1 - F for a total area of 28,595 square feet
+ Built in 1984
+ 16’ ceiling height
+ 100% conditioned throughout
+ 100% sprinklered
+ 2.39/1,000 SF parking ratio
+ $10.50 - $12.00/SF, NNN lease rate
+ $3.00/SF TICAM (2017)CONTACT US
J.D. “BUTCH” MILLERSenior Vice President+1 919 831 [email protected]
ANN-STEWART PATTERSON, SIORVice President+1 919 831 [email protected]
www.cbre.us/raleigh
FOR LEASE
OFFICE/FLEX SPACECOMMERCIAL PARK WEST4915 PROSPECTUS DRIVE & 2300 ENGLERT DRIVEDurham, NC 27713
Part of the CBRE affiliate network
FLOOR PLAN
FOR LEASEOFFICE/FLEX SPACE
COMMERCIAL PARK WESTDurham, NC 27713
SUITE C-16,208 SFAvailable April 1, 2017
FLOOR PLAN
FOR LEASEOFFICE/FLEX SPACE
COMMERCIAL PARK WESTDurham, NC 27713
SUITE C-27,387 SFAvailable April 1, 2017
FLOOR PLAN
FOR LEASEOFFICE/FLEX SPACE
COMMERCIAL PARK WESTDurham, NC 27713
SUITE D5,000 SFAvailable August 1, 2017
HOOD 2
HO
OD
1
HO
OD
3H
OO
D 4
A
B
C
D
E
F
G
H I
J
KL
N
M
HO
OD
2
HO
OD
3H
OO
D 4
HO
OD
1
REFRIGERATOR ROOM
NEW LAB 1EXISTING LAB
NEW LAB 2
ADA MEN'SRESTROOM
ADA WOMEN'SRESTROOM
NEW BREAKAREA
EXIST.MEN'S
RR
EXIST.WOMEN'S
RR
STORAGE
NEW CONFERENCEROOM
A
B
J
C
D
E
F
I
K
G
H
L
N
M
ACCENT WALL
ACCENT WALL
ACCENT WALL
PRICING NOTES
1. PAINT THROUGHOUT, (1) COAT PRIMER AND (2) COATS EGGSHELL FINISH2. NEW CARPET THROUGHOUT, U.O.N. MANNINGTON; STYLE: EL-ARCADIS AND/OR SP-ARCADIS; COLOR:
DISTRICT. CONTACT SHANNON WHITE AT 720-492-3901 AND [email protected] FOR ARCADIS PRICING
3. VCT IN REFRIGERATOR ROOM, EXISTING LAB, NEW LAB 1, NEW LAB 2, BREAK AREA, ADA MEN'S RESTROOM, AND ADA WOMEN'S RESTROOM.
4. NEW PLASTIC LAMINATE CABINETRY AND COUNTERTOPS IN BREAK AREA.5. RELOCATE EXISTING LAB EQUIPMENT AND LAB CASEWORK, SEE EXISTING PLAN VS. NEW CONSTRUCTION
PLAN FOR LOCATIONS6. RUBBER BASE THROUGHOUT7. RELOCATE EXISTING EYEWASH STATIONS TO ALL NEW LABS, SEE PLAN FOR LOCATIONS8. RELOCATE EXISTING DISHWASHER, SEE PLAN FOR LOCATION9. RELOCATE EXISTING SINKS IN NEW LAB 2 AND ADA RESTROOMS, SEE PLAN FOR LOCATIONS10. RELOCATE EXISTING 30 GAL WATER HEATER, SEE PLAN FOR LOCATION11. OPENINGS IN DEMISING WALL TO BE FILLED IN (PRICE SEPARATELY, COST PROVIDED BY LESSOR), SEE PLAN
FOR LOCATIONS12. PATCH AND REPAIR CEILING AS REQUIRED13. RELOCATE ROOF BLOWER TO SERVICE HOODS 2, 3, AND 4. REDUCT AND RELOCATE FAN AS REQUIRED.14. REDUCT HOOD 1 AS REQUIRED, PROVIDE NEW FAN15. RELOCATE EXISTING WATER HEATER TO ABOVE THE CEILING IN ADA RESTROOMS
EQUIPMENT LEGEND
SYMBOL ITEM
A
B
C
D
E
F
G
H
I
J
K
L
M
ADDITIONAL NOTES
LABORATORY COUNTER
LABORATORY COUNTER WITH WALL CABINET ABOVE
FLOOR CENTRIFUGE 208 VOLTS, 60 HZ, 20 AMPS
LABORATORY COUNTER WITH WALL CABINET ABOVE
LARGE THREE DOOR REFRIGERATOR 115 VOLTS, 60 HX, 11.3, REQUIRES DEDICATED CIRCUIT
LABORATORY COUNTER WITH WALL CABINET ABOVE, FUME HOOD IN CENTER
TRIPLE SINK
SCIENTIFIC DISHWASHER 208 VOLT, THREE PHASE, HOT AND COLD RUNNING WATER, DEIONIZED WATER (DEIONIZED WATER CONNECTION TO BE HANDLED BY ARCADIS' SUBCONTRACTOR)
THREE SINGLE DOOR REFRIGERATOR/FREEZER COMBO
FREESTANDING EQUIPMENT REQUIRES 110 VOLT OUTLET (DEDICATED CIRCUIT NOT REQUIRED)
FREESTANDING CHEMICAL STORAGE CABINETS
ARCADIS STAFF TO RELOCATE
FREESTANDING LABORATORY COUNTER 110 VOLT DROP FROM CEILING REQUIRED
LABORATORY OVEN 110 VOLT, RELOCATE EXISTING DUCTING TO CONNECT TO ROOFTOP BLOWER FOR HOOD 2
N FREESTANDING WORKTABLES 110 VOLT DROP FROM CEILING REQUIRED
EXISTING CABINETS TO BE RELOCATED, NEW COUNTERTOP REQUIRED
DEDICATED CIRCUIT REQUIRED
PARTITION LEGEND
EXISTING PARTITION TO BE DEMOLISHED
EXISTING PARTITION TO REMAIN
NEW PARTITION, PROVIDE 3 5/8" METAL STUDS WITH 5/8" GWB BOTH SIDES; HEIGHT OF WALL TO MATCH ADJACENT
NEW 1 HOUR RATED BARRIER
ARCHITECTURELANDSCAPE ARCHITECTUREPLANNINGINTERIOR DESIGN
PO BOX1308300 SOUTH DAWSON STREETRALEIGH, NORTH CAROLINA 27602919.821.5547www.hagersmith.com
© Copyright 2016
SEALS
ASSOCIATES /
CLIENT
DRAWING TITLE
DATE
DRAWN BY
CHECKED BY
OFDATE ISSUED
REVISIONS
NUMBER DESCRIPTION
PROJECT
PRELIMINARYNOT FOR CONSTRUCTION
ARCADIS
4915 Prospectus Dr, Suite FDurham, NC
DEMO & CONSTRUCTION PLAN
A-101LNSSET1.31.17 1 1
888-594-022
ARCADIS
1/8" = 1'-0"A-101
1 DEMO PLAN 1/8" = 1'-0"A-101
2 CONSTRUCTION PLAN
FLOOR PLAN
FOR LEASEOFFICE/FLEX SPACE
COMMERCIAL PARK WESTDurham, NC 27713
HOOD 2
HO
OD
1
HO
OD
3H
OO
D 4
A
B
C
D
E
F
G
H I
J
KL
N
M
HO
OD
2
HO
OD
3H
OO
D 4
HO
OD
1
REFRIGERATOR ROOM
NEW LAB 1EXISTING LAB
NEW LAB 2
ADA MEN'SRESTROOM
ADA WOMEN'SRESTROOM
NEW BREAKAREA
EXIST.MEN'S
RR
EXIST.WOMEN'S
RR
STORAGE
NEW CONFERENCEROOM
A
B
J
C
D
E
F
I
K
G
H
L
N
M
ACCENT WALL
ACCENT WALL
ACCENT WALL
PRICING NOTES
1. PAINT THROUGHOUT, (1) COAT PRIMER AND (2) COATS EGGSHELL FINISH2. NEW CARPET THROUGHOUT, U.O.N. MANNINGTON; STYLE: EL-ARCADIS AND/OR SP-ARCADIS; COLOR:
DISTRICT. CONTACT SHANNON WHITE AT 720-492-3901 AND [email protected] FOR ARCADIS PRICING
3. VCT IN REFRIGERATOR ROOM, EXISTING LAB, NEW LAB 1, NEW LAB 2, BREAK AREA, ADA MEN'S RESTROOM, AND ADA WOMEN'S RESTROOM.
4. NEW PLASTIC LAMINATE CABINETRY AND COUNTERTOPS IN BREAK AREA.5. RELOCATE EXISTING LAB EQUIPMENT AND LAB CASEWORK, SEE EXISTING PLAN VS. NEW CONSTRUCTION
PLAN FOR LOCATIONS6. RUBBER BASE THROUGHOUT7. RELOCATE EXISTING EYEWASH STATIONS TO ALL NEW LABS, SEE PLAN FOR LOCATIONS8. RELOCATE EXISTING DISHWASHER, SEE PLAN FOR LOCATION9. RELOCATE EXISTING SINKS IN NEW LAB 2 AND ADA RESTROOMS, SEE PLAN FOR LOCATIONS10. RELOCATE EXISTING 30 GAL WATER HEATER, SEE PLAN FOR LOCATION11. OPENINGS IN DEMISING WALL TO BE FILLED IN (PRICE SEPARATELY, COST PROVIDED BY LESSOR), SEE PLAN
FOR LOCATIONS12. PATCH AND REPAIR CEILING AS REQUIRED13. RELOCATE ROOF BLOWER TO SERVICE HOODS 2, 3, AND 4. REDUCT AND RELOCATE FAN AS REQUIRED.14. REDUCT HOOD 1 AS REQUIRED, PROVIDE NEW FAN15. RELOCATE EXISTING WATER HEATER TO ABOVE THE CEILING IN ADA RESTROOMS
EQUIPMENT LEGEND
SYMBOL ITEM
A
B
C
D
E
F
G
H
I
J
K
L
M
ADDITIONAL NOTES
LABORATORY COUNTER
LABORATORY COUNTER WITH WALL CABINET ABOVE
FLOOR CENTRIFUGE 208 VOLTS, 60 HZ, 20 AMPS
LABORATORY COUNTER WITH WALL CABINET ABOVE
LARGE THREE DOOR REFRIGERATOR 115 VOLTS, 60 HX, 11.3, REQUIRES DEDICATED CIRCUIT
LABORATORY COUNTER WITH WALL CABINET ABOVE, FUME HOOD IN CENTER
TRIPLE SINK
SCIENTIFIC DISHWASHER 208 VOLT, THREE PHASE, HOT AND COLD RUNNING WATER, DEIONIZED WATER (DEIONIZED WATER CONNECTION TO BE HANDLED BY ARCADIS' SUBCONTRACTOR)
THREE SINGLE DOOR REFRIGERATOR/FREEZER COMBO
FREESTANDING EQUIPMENT REQUIRES 110 VOLT OUTLET (DEDICATED CIRCUIT NOT REQUIRED)
FREESTANDING CHEMICAL STORAGE CABINETS
ARCADIS STAFF TO RELOCATE
FREESTANDING LABORATORY COUNTER 110 VOLT DROP FROM CEILING REQUIRED
LABORATORY OVEN 110 VOLT, RELOCATE EXISTING DUCTING TO CONNECT TO ROOFTOP BLOWER FOR HOOD 2
N FREESTANDING WORKTABLES 110 VOLT DROP FROM CEILING REQUIRED
EXISTING CABINETS TO BE RELOCATED, NEW COUNTERTOP REQUIRED
DEDICATED CIRCUIT REQUIRED
PARTITION LEGEND
EXISTING PARTITION TO BE DEMOLISHED
EXISTING PARTITION TO REMAIN
NEW PARTITION, PROVIDE 3 5/8" METAL STUDS WITH 5/8" GWB BOTH SIDES; HEIGHT OF WALL TO MATCH ADJACENT
NEW 1 HOUR RATED BARRIER
ARCHITECTURELANDSCAPE ARCHITECTUREPLANNINGINTERIOR DESIGN
PO BOX1308300 SOUTH DAWSON STREETRALEIGH, NORTH CAROLINA 27602919.821.5547www.hagersmith.com
© Copyright 2016
SEALS
ASSOCIATES /
CLIENT
DRAWING TITLE
DATE
DRAWN BY
CHECKED BY
OFDATE ISSUED
REVISIONS
NUMBER DESCRIPTION
PROJECT
PRELIMINARYNOT FOR CONSTRUCTION
ARCADIS
4915 Prospectus Dr, Suite FDurham, NC
DEMO & CONSTRUCTION PLAN
A-101LNSSET1.31.17 1 1
888-594-022
ARCADIS
1/8" = 1'-0"A-101
1 DEMO PLAN 1/8" = 1'-0"A-101
2 CONSTRUCTION PLAN
SUITE E5,000 SFAvailable August 1, 2017
FLOOR PLAN
FOR LEASEOFFICE/FLEX SPACE
COMMERCIAL PARK WESTDurham, NC 27713
HOOD 2
HO
OD
1
HO
OD
3H
OO
D 4
A
B
C
D
E
F
G
H I
J
KL
N
M
HO
OD
2
HO
OD
3H
OO
D 4
HO
OD
1
REFRIGERATOR ROOM
NEW LAB 1EXISTING LAB
NEW LAB 2
ADA MEN'SRESTROOM
ADA WOMEN'SRESTROOM
NEW BREAKAREA
EXIST.MEN'S
RR
EXIST.WOMEN'S
RR
STORAGE
NEW CONFERENCEROOM
A
B
J
C
D
E
F
I
K
G
H
L
N
M
ACCENT WALL
ACCENT WALL
ACCENT WALL
PRICING NOTES
1. PAINT THROUGHOUT, (1) COAT PRIMER AND (2) COATS EGGSHELL FINISH2. NEW CARPET THROUGHOUT, U.O.N. MANNINGTON; STYLE: EL-ARCADIS AND/OR SP-ARCADIS; COLOR:
DISTRICT. CONTACT SHANNON WHITE AT 720-492-3901 AND [email protected] FOR ARCADIS PRICING
3. VCT IN REFRIGERATOR ROOM, EXISTING LAB, NEW LAB 1, NEW LAB 2, BREAK AREA, ADA MEN'S RESTROOM, AND ADA WOMEN'S RESTROOM.
4. NEW PLASTIC LAMINATE CABINETRY AND COUNTERTOPS IN BREAK AREA.5. RELOCATE EXISTING LAB EQUIPMENT AND LAB CASEWORK, SEE EXISTING PLAN VS. NEW CONSTRUCTION
PLAN FOR LOCATIONS6. RUBBER BASE THROUGHOUT7. RELOCATE EXISTING EYEWASH STATIONS TO ALL NEW LABS, SEE PLAN FOR LOCATIONS8. RELOCATE EXISTING DISHWASHER, SEE PLAN FOR LOCATION9. RELOCATE EXISTING SINKS IN NEW LAB 2 AND ADA RESTROOMS, SEE PLAN FOR LOCATIONS10. RELOCATE EXISTING 30 GAL WATER HEATER, SEE PLAN FOR LOCATION11. OPENINGS IN DEMISING WALL TO BE FILLED IN (PRICE SEPARATELY, COST PROVIDED BY LESSOR), SEE PLAN
FOR LOCATIONS12. PATCH AND REPAIR CEILING AS REQUIRED13. RELOCATE ROOF BLOWER TO SERVICE HOODS 2, 3, AND 4. REDUCT AND RELOCATE FAN AS REQUIRED.14. REDUCT HOOD 1 AS REQUIRED, PROVIDE NEW FAN15. RELOCATE EXISTING WATER HEATER TO ABOVE THE CEILING IN ADA RESTROOMS
EQUIPMENT LEGEND
SYMBOL ITEM
A
B
C
D
E
F
G
H
I
J
K
L
M
ADDITIONAL NOTES
LABORATORY COUNTER
LABORATORY COUNTER WITH WALL CABINET ABOVE
FLOOR CENTRIFUGE 208 VOLTS, 60 HZ, 20 AMPS
LABORATORY COUNTER WITH WALL CABINET ABOVE
LARGE THREE DOOR REFRIGERATOR 115 VOLTS, 60 HX, 11.3, REQUIRES DEDICATED CIRCUIT
LABORATORY COUNTER WITH WALL CABINET ABOVE, FUME HOOD IN CENTER
TRIPLE SINK
SCIENTIFIC DISHWASHER 208 VOLT, THREE PHASE, HOT AND COLD RUNNING WATER, DEIONIZED WATER (DEIONIZED WATER CONNECTION TO BE HANDLED BY ARCADIS' SUBCONTRACTOR)
THREE SINGLE DOOR REFRIGERATOR/FREEZER COMBO
FREESTANDING EQUIPMENT REQUIRES 110 VOLT OUTLET (DEDICATED CIRCUIT NOT REQUIRED)
FREESTANDING CHEMICAL STORAGE CABINETS
ARCADIS STAFF TO RELOCATE
FREESTANDING LABORATORY COUNTER 110 VOLT DROP FROM CEILING REQUIRED
LABORATORY OVEN 110 VOLT, RELOCATE EXISTING DUCTING TO CONNECT TO ROOFTOP BLOWER FOR HOOD 2
N FREESTANDING WORKTABLES 110 VOLT DROP FROM CEILING REQUIRED
EXISTING CABINETS TO BE RELOCATED, NEW COUNTERTOP REQUIRED
DEDICATED CIRCUIT REQUIRED
PARTITION LEGEND
EXISTING PARTITION TO BE DEMOLISHED
EXISTING PARTITION TO REMAIN
NEW PARTITION, PROVIDE 3 5/8" METAL STUDS WITH 5/8" GWB BOTH SIDES; HEIGHT OF WALL TO MATCH ADJACENT
NEW 1 HOUR RATED BARRIER
ARCHITECTURELANDSCAPE ARCHITECTUREPLANNINGINTERIOR DESIGN
PO BOX1308300 SOUTH DAWSON STREETRALEIGH, NORTH CAROLINA 27602919.821.5547www.hagersmith.com
© Copyright 2016
SEALS
ASSOCIATES /
CLIENT
DRAWING TITLE
DATE
DRAWN BY
CHECKED BY
OFDATE ISSUED
REVISIONS
NUMBER DESCRIPTION
PROJECT
PRELIMINARYNOT FOR CONSTRUCTION
ARCADIS
4915 Prospectus Dr, Suite FDurham, NC
DEMO & CONSTRUCTION PLAN
A-101LNSSET1.31.17 1 1
888-594-022
ARCADIS
1/8" = 1'-0"A-101
1 DEMO PLAN 1/8" = 1'-0"A-101
2 CONSTRUCTION PLAN
SUITE F5,000 SFAvailable August 1, 2017
FLOOR PLAN
FOR LEASEOFFICE/FLEX SPACE
COMMERCIAL PARK WESTDurham, NC 27713
SUITES C-1, C-2, D, E & F28,595 SF
HOOD 2
HO
OD
1
HO
OD
3H
OO
D 4
A
B
C
D
E
F
G
H I
J
KL
N
M
HO
OD
2
HO
OD
3H
OO
D 4
HO
OD
1
REFRIGERATOR ROOM
NEW LAB 1EXISTING LAB
NEW LAB 2
ADA MEN'SRESTROOM
ADA WOMEN'SRESTROOM
NEW BREAKAREA
EXIST.MEN'S
RR
EXIST.WOMEN'S
RR
STORAGE
NEW CONFERENCEROOM
A
B
J
C
D
E
F
I
K
G
H
L
N
M
ACCENT WALL
ACCENT WALL
ACCENT WALL
PRICING NOTES
1. PAINT THROUGHOUT, (1) COAT PRIMER AND (2) COATS EGGSHELL FINISH2. NEW CARPET THROUGHOUT, U.O.N. MANNINGTON; STYLE: EL-ARCADIS AND/OR SP-ARCADIS; COLOR:
DISTRICT. CONTACT SHANNON WHITE AT 720-492-3901 AND [email protected] FOR ARCADIS PRICING
3. VCT IN REFRIGERATOR ROOM, EXISTING LAB, NEW LAB 1, NEW LAB 2, BREAK AREA, ADA MEN'S RESTROOM, AND ADA WOMEN'S RESTROOM.
4. NEW PLASTIC LAMINATE CABINETRY AND COUNTERTOPS IN BREAK AREA.5. RELOCATE EXISTING LAB EQUIPMENT AND LAB CASEWORK, SEE EXISTING PLAN VS. NEW CONSTRUCTION
PLAN FOR LOCATIONS6. RUBBER BASE THROUGHOUT7. RELOCATE EXISTING EYEWASH STATIONS TO ALL NEW LABS, SEE PLAN FOR LOCATIONS8. RELOCATE EXISTING DISHWASHER, SEE PLAN FOR LOCATION9. RELOCATE EXISTING SINKS IN NEW LAB 2 AND ADA RESTROOMS, SEE PLAN FOR LOCATIONS10. RELOCATE EXISTING 30 GAL WATER HEATER, SEE PLAN FOR LOCATION11. OPENINGS IN DEMISING WALL TO BE FILLED IN (PRICE SEPARATELY, COST PROVIDED BY LESSOR), SEE PLAN
FOR LOCATIONS12. PATCH AND REPAIR CEILING AS REQUIRED13. RELOCATE ROOF BLOWER TO SERVICE HOODS 2, 3, AND 4. REDUCT AND RELOCATE FAN AS REQUIRED.14. REDUCT HOOD 1 AS REQUIRED, PROVIDE NEW FAN15. RELOCATE EXISTING WATER HEATER TO ABOVE THE CEILING IN ADA RESTROOMS
EQUIPMENT LEGEND
SYMBOL ITEM
A
B
C
D
E
F
G
H
I
J
K
L
M
ADDITIONAL NOTES
LABORATORY COUNTER
LABORATORY COUNTER WITH WALL CABINET ABOVE
FLOOR CENTRIFUGE 208 VOLTS, 60 HZ, 20 AMPS
LABORATORY COUNTER WITH WALL CABINET ABOVE
LARGE THREE DOOR REFRIGERATOR 115 VOLTS, 60 HX, 11.3, REQUIRES DEDICATED CIRCUIT
LABORATORY COUNTER WITH WALL CABINET ABOVE, FUME HOOD IN CENTER
TRIPLE SINK
SCIENTIFIC DISHWASHER 208 VOLT, THREE PHASE, HOT AND COLD RUNNING WATER, DEIONIZED WATER (DEIONIZED WATER CONNECTION TO BE HANDLED BY ARCADIS' SUBCONTRACTOR)
THREE SINGLE DOOR REFRIGERATOR/FREEZER COMBO
FREESTANDING EQUIPMENT REQUIRES 110 VOLT OUTLET (DEDICATED CIRCUIT NOT REQUIRED)
FREESTANDING CHEMICAL STORAGE CABINETS
ARCADIS STAFF TO RELOCATE
FREESTANDING LABORATORY COUNTER 110 VOLT DROP FROM CEILING REQUIRED
LABORATORY OVEN 110 VOLT, RELOCATE EXISTING DUCTING TO CONNECT TO ROOFTOP BLOWER FOR HOOD 2
N FREESTANDING WORKTABLES 110 VOLT DROP FROM CEILING REQUIRED
EXISTING CABINETS TO BE RELOCATED, NEW COUNTERTOP REQUIRED
DEDICATED CIRCUIT REQUIRED
PARTITION LEGEND
EXISTING PARTITION TO BE DEMOLISHED
EXISTING PARTITION TO REMAIN
NEW PARTITION, PROVIDE 3 5/8" METAL STUDS WITH 5/8" GWB BOTH SIDES; HEIGHT OF WALL TO MATCH ADJACENT
NEW 1 HOUR RATED BARRIER
ARCHITECTURELANDSCAPE ARCHITECTUREPLANNINGINTERIOR DESIGN
PO BOX1308300 SOUTH DAWSON STREETRALEIGH, NORTH CAROLINA 27602919.821.5547www.hagersmith.com
© Copyright 2016
SEALS
ASSOCIATES /
CLIENT
DRAWING TITLE
DATE
DRAWN BY
CHECKED BY
OFDATE ISSUED
REVISIONS
NUMBER DESCRIPTION
PROJECT
PRELIMINARYNOT FOR CONSTRUCTION
ARCADIS
4915 Prospectus Dr, Suite FDurham, NC
DEMO & CONSTRUCTION PLAN
A-101LNSSET1.31.17 1 1
888-594-022
ARCADIS
1/8" = 1'-0"A-101
1 DEMO PLAN 1/8" = 1'-0"A-101
2 CONSTRUCTION PLAN
SUITE C-16,208 SFAvailable 4/2017
SUITE C-27,387 SFAvailable 4/2017
SUITE D5,000 SFAvailable 8/2017
SUITE E5,000 SFAvailable 8/2017
SUITE F5,000 SFAvailable 8/2017
© 2015 CBRE Limited. Data © TeleAtlas, Google, AerialExpress, DigitalGlobe, Landiscor, USGS, i-cubed. The information contained herein (the “Information”) is intended for informational purposes only and should not be relied upon by recipients hereof. Although the Information is believed to be correct, its accuracy, correctness or completeness cannot be guaranteed and has not been verified byeither CBRE Limited or any of its affiliates (CBRE Limited and its affiliates are collectively referred to herein as “CBRE”). CBRE neither guarantees, warrants nor assumes any responsibility or liability of any kind with respect to the accuracy, correctness, completeness, or suitability of, or decisions based upon or in connection with, the Information. The recipient of the Information should take suchsteps as the recipient may deem appropriate with respect to using the Information. The Information may change and any property described herein may be withdrawn from the market at any time without notice or obligation of any kind on the part of CBRE. The Information is protected by copyright and shall be fully enforced.
Layout ID:L01 MapId:3123984
BUILDING PLAN
© 2017 CB Richard Ellis - Raleigh LLC. The information contained in this document has been obtained from sources believed reliable. While CB Richard Ellis - Raleigh LLC does not doubt its accuracy, CB Richard Ellis - Raleigh LLC has not verified it and makes no guarantee, warranty or representation about it. It is your responsibility to independently confirm its accuracy and completeness. Any projections, opinions, assumptions or estimates used are for example only and do not represent the current or future performance of the property. The value of this transaction to you depends on tax and other factors which should be evaluated by your tax, financial and legal advisors. You and your advisors should conduct a careful, independent investigation of the property to determine to your satisfaction the suitability of the property for your needs.
Photos herein are the property of their respective owners and use of these images without the express written consent of the owner is prohibited.
www.cbre.us/raleigh
FOR LEASEOFFICE/FLEX SPACE
COMMERCIAL PARK WESTDurham, NC 27713
Part of the CBRE affiliate network
SUITE C-1
SUITE C-2
SUITE D
SUITE E
SUITE F