STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com1 / 16
LM-79-08 Test ReportFor
Beyond LED Technology(Brand Name: Beyond LED)
1939 Parker Ct Suite C
Stone Mountain, GA 30087
Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted
Area Luminaires
Model name(s): BLT-WP03-20WC1
Representative (Tested) Model: SNC-WP03-20WC1 3000KSNC-WP03-20WC1 5700K
Model Different: All construction and rating are the same, except CCT.
Test & Report By: Review By:
Jack LuoEngineer: Jack Luo Manager: Tommy LiangDate:Apr.17,2017
Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, orany agency of the Federal Government.
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com2 / 16
1.1 Product Information:Organization Name Beyond LED Technology
Brand Name Beyond LEDModel Number BLT-WP03-20WC1
SKU (if available) 150825
Type of Luminaire (for integral lamps,list base type and lamp type)
Outdoor Non-Cutoff and Semi-Cutoff Wall-Mounted AreaLuminaires
Rated Voltage / Frequency 100 -277Vac, 50/60 HzNominal Power 20WRated Initial Lamp Lumen --Declared CCT 3000K,3500K,4000K,4500K,5000K,5700KLED Manufacturer Shenzhen WeiXingXin Electronics Technology Co.,Ltd.LED Model 2835 WHITE SMD LEDSample Number GZE1703139-C1(3000K), C2(5700K)Luminaire Aperture (for downlights) -- in.Luminaire Length -- mmLuminaires Width -- mmNumber of Units (modular products) N/A s
Photo
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com3 / 16
1.2 Test Specifications:Date of Receipt Apr.13,2017Date of Test Apr.14,2017
Test item
1. Total Luminous Flux2. Luminous Distribution Intensity3. Luminous Efficacy4. Correlated Color Temperature5. Color Rendering Index6. Chromaticity Coordinate7. Electrical Parameters
Reference Standard
1. IES LM-79-2008 Electrical and Photometric Measurements ofSolid-State Lighting Products
2. ANSI C78.377-2008 Specifications for the Chromaticity of SolidState Lighting Products
3. CIE 13.3-1995 Method of Measuring and Specifying ColourRendering Properties of Light Sources
4. CIE 15-2004 Technical Report Colorimetry5. IESNA LM-16-93 Practical Guide to Colorimetry of Light Source6. IESNATM-16-05 Technical Memorandum on Light Emitting
Diode (LED) Sources and SystemsReference Work Instruction QD25
1.3 Test Methods1) Photometric and Light Distribution Measurement – Goniophotometer Method:Photometric parameters were measured using the goniophotometer and software. The ambienttemperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from thesample and at the same height as the sample. The sample was operated at 120 or rated Volts AC, 60Hz.It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen werecalculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.2) Chromaticity Measurement – Sphere-Spectroradiometer Method:Chromaticity parameters were measured using an integrating sphere, a spectroradiometer and software.The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The samplemeasurements were made using a spectroradiometer connected by a fiber optic cable and detectorthrough the detector port of the integrating sphere. The sample was operated at 120 or rated Volts AC,60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated colortemperature and color rendering index were calculated from the spectral power distribution taken at 5nm intervals over the range of 380 to 780 nm.3) Electrical Measurements:Electrical parameters were measured using power meters incorporated in goniophotometer orsphere-spectroradiometer system. The ambient temperature surrounding the sample was maintained at25º C ± 1º C. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized beforemeasurement was made. Voltage, frequency, current, power, power factor and total harmonic distortionwere measured by and read from the power meter.
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com4 / 16
2.1 Electrical, Photometric and Chromaticity Measurements(Refer to Work Instruction QD25)
Test date 2017-04-14 Test Ambient: 25.2 º C
Test Orientation As intended Stabilization Time (min) 90
Model Number BLT-WP03-20WC1 3000K
Electrical Measurement :Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD%
GZE1703139-C1
120.0 60 0.1708 19.53 0.9531 17.22277.0 60 0.0751 19.74 0.9486 20.25
DLC Pass Criteria >= 0.9(-3%) <= 20(+5)
Chromaticity Measurement - Sphere-Spectroradiometer Method :Parameter Result Special Color Rendering IndicesTest Voltage (V) 120.0 R1 82 R9 6Frequency (Hz) 60 R2 93 R10 84CCT (K) 2986 R3 94 R11 79Duv -0.0010 R4 79 R12 73Chromaticity (x, y) x=0.4365 y=0.4015 R5 82 R13 85Chromaticity (u’, v’) u'=0.2514 v'=0.5203 R6 92 R14 97Color Rendering Index (CRI) 82.4 R7 81 R15 74R9 6 R8 57 -- --
Photometric Measurement – Goniophotometer Method :Parameter Result DLC V4.1 Pass CriteriaTest Voltage (V) 120.0 277.0
--Frequency (Hz) 60 60Total Luminous (lm) 2078.3 2092.2 300-5000 (-10%)Luminous Efficacy (lm/W) 106.42 105.99 --Total Luminous (lm) (0-90°zone) 1873.8 1883.8 --Luminous Efficacy (lm/W)(0-90°zone)
95.94 95.43Standard: >=90(-3%)
Premium: >=110(-3%)
Zonal lumens in the 80-90°zone(%)(0-90°zone)
10.7 -- <=10(+3)
BeamAngle (°) 100.6 -- --Center Beam Candle Power (cd) 463 -- --
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com5 / 16
Zonal Lumen Tabulation
Zonal Lumen Summary
Zone Lumens % Luminaire
0-30 355.7 17.1%
0-40 593.7 28.6%
0-60 1,147.8 55.2%
60-90 726.0 34.9%
70-100 545.9 26.3%
90-120 192.7 9.3%
0-90 1,873.8 90.2%
90-180 204.5 9.8%
0-180 2,078.3 100%
Lumens Per Zone
Zone Lumens % Total Zone Lumens % Total
0-10 43.5 2.1% 90-100 97.0 4.7%
10-20 120.8 5.8% 100-110 60.2 2.9%
20-30 191.5 9.2% 110-120 35.5 1.7%
30-40 238.0 11.4% 120-130 8.5 0.4%
40-50 269.0 12.9% 130-140 1.5 0.1%
50-60 285.1 13.7% 140-150 1.0 0%
60-70 277.1 13.3% 150-160 0.5 0%
70-80 247.9 11.9% 160-170 0.2 0%
80-90 201.0 9.7% 170-180 0.0 0%
Spectral Power Distribution & Chromaticity Diagram
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com6 / 16
Photometric Data
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com7 / 16
Candela Table - Type C
0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360
0 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463 463
1 472 468 462 460 470 470 469 467 468 469 472 472 467 457 464 468 472
2 486 486 477 460 471 466 444 425 424 427 452 472 465 462 480 486 486
3 492 485 486 463 472 450 423 426 424 428 422 462 463 471 484 486 492
4 529 515 485 470 471 425 426 407 408 409 430 443 462 482 487 519 529
5 536 539 500 475 467 421 406 432 427 432 417 425 460 485 514 537 536
6 507 526 518 476 462 421 429 410 397 413 416 423 456 481 534 515 507
7 509 506 529 475 458 410 418 381 376 389 432 425 453 479 527 508 509
8 529 511 512 471 453 393 395 380 385 381 411 422 448 486 501 520 529
9 536 528 490 471 451 399 371 396 394 392 395 410 442 495 498 537 536
10 525 529 484 475 446 412 370 375 352 390 374 393 440 503 505 526 525
11 521 515 489 481 444 409 379 346 339 356 374 396 437 509 513 526 521
12 542 516 501 488 438 405 381 337 345 340 381 411 435 503 514 520 542
13 541 520 502 492 430 394 352 349 332 343 387 414 434 496 500 548 541
14 543 541 497 494 422 377 332 323 305 345 366 406 431 482 496 537 543
15 526 519 485 491 413 361 323 302 318 312 336 407 427 474 502 539 526
16 522 522 491 485 408 353 328 319 356 303 325 399 423 474 504 520 522
17 560 505 502 478 405 348 329 349 307 345 318 383 420 478 525 518 560
18 547 513 499 466 403 355 306 301 313 336 331 372 416 480 510 549 547
19 557 538 506 457 401 354 291 306 323 299 327 365 413 477 493 545 557
20 576 526 495 451 400 356 299 316 298 315 304 356 413 475 499 539 576
21 605 525 471 448 397 348 335 303 293 320 293 346 414 469 498 559 605
22 604 544 477 450 393 331 315 285 301 296 301 344 413 463 498 579 604
23 615 574 496 450 386 304 283 292 277 281 331 340 413 466 510 598 615
24 657 594 491 447 380 290 288 283 291 292 327 341 413 469 522 590 657
25 675 584 482 440 376 285 291 273 279 273 293 343 414 469 507 626 675
26 689 608 489 436 371 281 288 280 275 267 277 340 413 469 505 647 689
27 688 633 493 434 370 279 264 264 269 278 288 329 412 461 526 658 688
28 695 638 495 431 366 283 256 257 256 261 293 312 411 454 555 665 695
29 684 643 496 426 362 288 262 248 251 258 278 301 405 443 591 667 684
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com8 / 16
30 686 639 516 422 355 278 256 241 243 245 252 286 402 434 588 671 686
31 698 646 539 420 349 269 239 231 230 239 249 279 396 433 564 660 698
32 697 644 568 417 345 256 247 223 218 228 259 270 392 437 578 664 697
33 688 638 582 411 343 248 233 207 190 221 250 265 384 434 596 665 688
34 663 635 545 409 334 249 229 191 163 207 229 264 375 433 598 657 663
35 647 625 526 404 329 257 218 170 140 192 237 265 365 431 596 643 647
36 643 605 538 399 324 259 210 139 120 169 231 263 360 426 595 623 643
37 676 592 554 390 317 256 200 121 104 146 218 265 352 426 591 616 676
38 711 589 562 386 310 248 191 110 80 132 210 258 348 433 595 623 711
39 750 596 558 384 298 226 187 93 64 113 206 249 343 440 588 645 750
40 752 620 545 382 295 219 169 77 56 96 197 239 338 445 563 690 752
41 769 650 519 382 292 218 155 64 57 83 184 230 334 446 535 713 769
42 774 677 499 381 289 212 141 59 56 70 175 223 328 441 525 721 774
43 771 692 491 379 285 205 130 58 59 64 162 220 316 431 528 718 771
44 781 686 489 375 273 193 116 56 62 63 148 219 305 416 543 730 781
45 815 695 492 367 263 182 106 57 65 61 135 217 302 405 571 739 815
46 846 719 506 358 258 170 93 58 65 59 121 218 304 394 592 757 846
47 869 746 535 350 259 165 84 59 65 59 110 211 298 388 604 789 869
48 888 773 554 340 252 157 78 58 64 59 98 195 290 387 615 830 888
49 868 804 569 333 240 145 73 57 62 60 89 175 285 385 621 839 868
50 821 801 577 326 237 136 69 56 61 58 80 166 281 376 629 827 821
51 766 761 584 323 231 125 67 54 64 57 75 155 276 368 653 803 766
52 739 727 589 320 223 111 66 53 65 56 69 151 271 370 676 750 739
53 729 682 591 318 216 103 64 52 66 54 66 143 267 380 696 687 729
54 738 639 593 313 209 89 64 53 66 52 62 131 254 387 696 671 738
55 766 628 591 311 202 79 65 52 63 51 59 117 247 394 679 685 766
56 823 658 574 320 196 73 64 51 61 50 57 105 243 411 636 716 823
57 854 715 550 329 187 66 59 48 59 48 55 93 235 428 592 753 854
58 855 746 509 336 180 57 56 46 56 46 55 87 231 434 556 776 855
59 820 739 480 334 173 54 54 44 53 45 53 80 225 424 551 784 820
60 742 721 481 325 165 50 53 42 49 43 52 72 224 412 573 770 742
61 683 692 510 310 156 47 53 39 45 41 50 66 221 403 606 730 683
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com9 / 16
62 638 669 554 299 151 44 52 37 42 39 49 59 213 393 654 680 638
63 623 638 575 288 146 41 50 34 38 37 49 53 214 375 665 624 623
64 641 613 572 281 140 40 48 32 34 36 48 48 215 352 647 607 641
65 681 615 549 268 139 39 48 29 32 33 46 45 214 316 619 623 681
66 735 663 528 253 134 39 48 27 30 31 45 42 207 298 586 678 735
67 762 706 533 247 127 39 49 26 27 30 45 39 194 311 581 734 762
68 766 726 539 258 117 37 49 26 25 28 46 37 188 339 600 760 766
69 738 692 548 263 109 36 45 25 21 27 47 34 178 366 639 723 738
70 705 605 555 255 100 36 44 23 18 27 45 34 174 351 658 641 705
71 674 536 531 246 93 35 43 19 17 28 46 34 168 331 632 587 674
72 670 495 466 248 87 35 41 17 16 25 47 34 158 321 569 560 670
73 686 513 426 255 78 35 39 15 15 21 42 33 149 328 473 573 686
74 697 597 428 241 72 34 41 14 15 17 41 32 141 322 429 641 697
75 692 663 454 212 65 33 40 14 15 15 42 31 123 292 442 698 692
76 698 700 440 200 58 32 35 14 15 15 42 30 111 257 479 717 698
77 706 685 404 201 52 32 30 14 15 15 40 30 108 262 496 689 706
78 701 618 378 185 47 33 27 13 14 14 40 28 103 253 481 653 701
79 674 558 373 176 44 32 25 12 14 13 40 29 95 237 458 631 674
80 648 554 394 172 39 32 24 11 13 13 34 28 90 227 455 601 648
81 665 575 405 170 36 32 22 10 13 12 28 27 87 232 496 601 665
82 699 586 384 163 33 33 19 10 13 11 26 29 76 222 532 619 699
83 704 582 373 151 30 32 17 10 13 10 23 30 65 210 528 643 704
84 624 569 388 145 27 32 17 9 12 10 22 31 60 205 474 637 624
85 555 537 387 144 25 32 16 9 11 9 20 31 53 200 424 584 555
86 483 493 347 143 24 34 15 8 11 8 18 31 46 196 393 507 483
87 450 446 316 142 21 34 13 8 10 8 17 32 43 192 375 444 450
88 455 399 291 142 19 34 12 8 9 7 17 33 37 189 352 426 455
89 469 357 283 137 18 32 11 7 9 7 16 32 33 185 348 408 469
90 495 337 273 125 17 32 11 6 8 6 14 32 29 180 343 393 495
91 493 356 260 114 17 33 10 6 8 6 13 32 25 172 317 391 493
92 473 372 240 108 15 32 10 6 7 6 12 32 22 159 262 415 473
93 431 373 208 96 15 32 9 5 7 5 11 31 19 128 206 408 431
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com10 / 16
94 373 317 154 77 14 30 8 5 7 5 11 31 16 106 170 344 373
95 293 253 103 64 12 28 8 5 6 5 10 27 14 88 111 268 293
96 225 184 85 59 12 28 7 4 6 4 8 24 11 73 91 202 225
97 172 139 76 47 10 25 6 4 5 4 8 20 10 62 101 158 172
98 130 97 70 34 9 24 6 3 4 3 7 19 8 46 117 99 130
99 128 128 58 28 8 20 5 3 4 3 7 16 8 39 125 127 128
100 188 153 58 25 7 18 5 2 3 3 6 13 8 37 148 161 188
101 182 168 66 18 7 15 5 2 3 2 6 11 7 38 152 173 182
102 191 195 70 14 7 12 5 2 3 2 6 8 7 37 139 199 191
103 215 212 67 13 7 11 5 2 2 2 6 8 8 34 124 212 215
104 238 239 67 11 7 10 4 2 2 2 5 8 7 28 123 243 238
105 270 239 63 8 8 10 4 2 2 2 5 8 7 24 129 257 270
106 269 221 52 7 8 9 4 2 2 2 5 8 7 22 122 245 269
107 254 200 41 7 7 9 4 2 3 2 5 8 7 17 108 228 254
108 245 195 38 6 7 9 3 2 2 2 5 8 7 8 95 213 245
109 240 202 38 3 7 9 3 1 1 1 6 7 7 5 85 216 240
110 233 206 39 2 7 8 3 1 1 1 6 7 6 4 75 218 233
111 227 202 38 2 7 7 3 1 1 1 6 6 6 4 71 214 227
112 225 182 35 2 6 7 3 1 2 2 6 7 6 3 71 199 225
113 209 159 27 2 6 6 3 1 2 1 5 7 6 2 64 179 209
114 184 138 20 2 6 6 3 1 2 1 5 7 6 2 52 151 184
115 163 121 15 2 7 6 3 1 2 1 4 7 7 2 43 130 163
116 156 118 12 3 7 6 3 1 1 1 4 7 7 1 36 122 156
117 154 115 10 3 7 6 3 1 1 2 5 7 6 1 29 121 154
118 148 101 10 3 7 5 3 1 1 2 4 7 6 1 24 118 148
119 128 87 8 3 7 5 2 1 1 2 4 7 6 1 22 96 128
120 111 70 7 3 7 5 2 2 1 2 4 8 6 1 18 82 111
121 92 60 5 4 7 5 2 1 1 2 4 7 6 2 12 70 92
122 81 41 4 4 6 5 2 1 1 1 3 8 6 3 7 54 81
123 63 33 3 4 6 5 2 1 1 1 3 8 5 4 4 37 63
124 52 24 2 4 6 5 2 1 1 1 3 8 5 4 3 32 52
125 47 24 2 4 6 5 2 1 1 2 3 7 5 4 2 23 47
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com11 / 16
126 32 18 2 5 7 5 2 1 1 2 3 7 5 4 1 22 32
127 22 10 1 4 7 5 2 1 1 2 3 7 5 4 1 13 22
128 11 7 1 4 7 4 2 2 1 2 3 6 5 4 0 8 11
129 8 6 1 4 6 4 2 2 1 2 3 5 5 3 0 6 8
130 7 5 1 4 6 3 2 2 1 2 3 4 4 3 0 5 7
131 6 3 1 3 6 2 2 2 1 2 3 3 4 3 0 4 6
132 5 1 1 3 4 2 2 2 1 2 2 2 3 3 0 3 5
133 4 1 1 3 3 2 2 2 1 2 2 2 3 3 0 1 4
134 2 1 1 3 3 2 2 2 1 2 2 2 2 2 0 0 2
135 1 1 1 2 2 3 2 2 1 2 2 3 2 2 1 0 1
136 0 0 1 2 2 3 2 2 1 2 3 3 2 2 1 0 0
137 0 0 1 2 2 3 2 2 1 2 3 3 2 1 1 0 0
138 0 1 2 2 2 3 2 1 1 2 2 4 2 1 2 0 0
139 0 0 2 2 2 3 2 1 1 2 2 4 2 2 2 0 0
140 0 0 2 2 2 3 2 1 1 2 2 3 2 2 2 0 0
141 0 0 2 2 2 3 2 1 1 2 2 3 2 2 2 0 0
142 0 0 2 2 2 2 2 1 1 2 2 3 3 2 2 0 0
143 0 1 2 2 2 3 2 1 1 2 1 3 3 3 2 1 0
144 0 1 2 2 2 4 1 1 1 1 1 3 3 3 2 1 0
145 0 1 2 2 2 3 1 1 1 1 1 3 3 3 2 1 0
146 0 1 2 3 2 3 1 1 1 1 1 3 2 3 2 1 0
147 0 1 2 3 2 2 1 1 1 1 1 2 2 2 2 1 0
148 0 1 2 2 2 2 1 1 1 1 1 2 2 2 2 1 0
149 0 1 2 2 2 2 1 1 1 1 1 2 2 2 2 1 0
150 0 1 2 2 2 1 1 1 1 1 1 2 2 2 2 1 0
151 0 1 2 2 1 2 1 1 1 1 1 2 2 2 2 1 0
152 0 1 2 2 1 2 1 1 1 1 1 2 2 2 2 1 0
153 0 1 2 2 1 1 1 1 1 1 1 1 2 2 1 1 0
154 0 1 2 2 1 2 1 1 1 1 1 1 2 2 1 1 0
155 0 1 1 2 1 1 1 1 1 1 1 1 2 2 1 1 0
156 0 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 0
157 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com12 / 16
158 0 1 1 1 1 1 1 1 1 0 1 1 1 1 1 1 0
159 0 1 1 1 1 1 1 1 1 0 1 1 1 1 1 1 0
160 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0
161 0 1 1 1 1 1 1 1 1 0 1 1 1 1 1 0 0
162 0 0 1 1 1 1 1 1 1 0 1 1 1 1 1 0 0
163 0 0 1 1 1 0 1 1 1 0 1 1 1 1 1 0 0
164 0 0 1 1 1 1 1 1 1 1 0 1 1 1 1 0 0
165 0 0 1 1 0 1 1 1 0 0 0 1 1 1 1 0 0
166 0 0 1 1 1 1 1 1 0 0 0 1 1 0 1 0 0
167 0 0 1 1 0 1 1 1 1 1 0 1 1 0 0 0 0
168 0 0 0 1 0 1 1 1 1 1 1 1 1 0 0 0 0
169 0 0 0 1 0 1 1 1 1 1 0 1 0 0 0 0 0
170 0 0 0 0 0 1 1 1 1 1 0 1 1 0 0 0 0
171 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 0
172 0 0 0 0 0 0 0 1 1 1 0 1 0 0 0 0 0
173 0 0 0 0 0 0 0 1 1 1 0 0 1 0 0 0 0
174 0 0 0 0 0 1 0 1 1 1 0 0 0 0 0 0 0
175 0 0 0 0 0 0 0 1 1 1 0 0 1 0 0 0 0
176 0 0 0 0 0 0 0 1 1 1 0 0 0 0 0 0 0
177 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0
178 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0
179 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0
180 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com13 / 16
2.2 Electrical, Photometric and Chromaticity Measurements(Refer to Work Instruction QD25)
Test date 2017-04-14 Test Ambient: 25.2 º CTest Orientation As intended Stabilization Time (min) 90Model Number BLT-WP03-20WC1 5700K
Electrical Measurement:Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD%
GZE1703139-C2
120.0 60 0.1725 19.70 0.9519 17.30277.0 60 0.0758 19.91 0.9488 20.33
DLC Pass Criteria >= 0.9(-3%) <= 20(+5)
Chromaticity Measurement - Sphere-Spectroradiometer Method:Parameter Result Special Color Rendering IndicesTest Voltage (V) 120.0 R1 82 R9 11Frequency (Hz) 60 R2 89 R10 72CCT (K) 5644 R3 92 R11 80Duv 0.0026 R4 82 R12 56Chromaticity (x, y) x=0.3292 y=0.3433 R5 82 R13 84Chromaticity (u’, v’) u'=0.2038 v'=0.4782 R6 83 R14 96Color Rendering Index (CRI) 83.4 R7 88 R15 78R9 11 R8 69 -- --
Photometric Measurement – Sphere-Spectroradiometer Method :Parameter Result DLC V4.1 Pass CriteriaTest Voltage (V) 120.0 277.0
--Frequency (Hz) 60 60Total Luminous (lm) 2165 2168 300-5000 (-10%)Luminous Efficacy (lm/W) 109.90 108.89 --
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com14 / 16
Spectral Power Distribution & Chromaticity Diagram
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com15 / 16
2.3 Performance Assessment:
Model name CCT(K)Total Luminous
(lm)Power (W)
LuminousEfficacy (lm/W)
SNC-WP03-20WC1 3000K 3000K 2078.3 19.53 106.42SNC-WP03-20WC1 3500K 3500K 2096*1 19.62*2 106.83*3
SNC-WP03-20WC1 4000K 4000K 2113*1 19.62*2 107.70*3
SNC-WP03-20WC1 4500K 4500K 2130*1 19.62*2 108.56*3
SNC-WP03-20WC1 5000K 5000K 2147*1 19.62*2 109.43*3
SNC-WP03-20WC1 5700K 5700K 2165 19.70 109.90
*1: This value is calculated and the calculation formula is as below:2096=(2165-2078.3)/5+2078.32113=(2165-2078.3)/5+20962130=(2165-2078.3)/5+21132147=(2165-2078.3)/5+2130
*2: This value is calculated and the calculation formula is as below:19.62=(19.70+19.53)/2
*3: This value is calculated and the calculation formula is as below:106.83=2096/19.62107.70=2113/19.62108.56=2130/19.62109.43=2147/19.62
STANDARD-TECH Report No.: GZE1703139-C
Laboratory: Standard-Tech Co. Ltd Testing CenterNVLAPCODE: 201011-0
Report Format Number STD/QR4909-A/2Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China
Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com16 / 16
3. Test Equipment
Equipment ID Equipment Name Last Calibration Date Next Calibration Date
ST-R-331 2 meter Integrating Sphere 2016-07-01 2017-06-30
ST-R-327 Spectral analysis system HAAS-2000 2016-07-01 2017-06-30
D204 Standard Lamp 2016-07-12 2017-07-11
PF2010 Power Meter for Integrating Sphere 2016-07-01 2017-06-30
GO-R5000 Goniophotometer system 2016-07-01 2017-06-30
D908S Standard Lamp 2016-07-12 2017-07-11
PF210 Power Meter for Goniophotometer 2016-07-07 2017-07-06
Expand Uncertainty:Photometric Measurement (Sphere):2.04%, k=2Chromaticity Measurement(Sphere):28.8K, k=2Photometric Measurement(Goniophotometer):2.36%, k=2
****** END OF REPORT ******