FMK Cassette Filter FMK.0211.1 Click to go to the page

FMK Cassette Filter - Hebron PM · 2017. 10. 5. · from the plant travels down the supply duct 2. A standard baffle is mounted at the inlet of the filter to break up the air flow

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FMK Cassette Filter - Hebron PM · 2017. 10. 5. · from the plant travels down the supply duct 2. A standard baffle is mounted at the inlet of the filter to break up the air flow

FMKCassette Filter

FMK.0211.1Click to go to the page

Page 2: FMK Cassette Filter - Hebron PM · 2017. 10. 5. · from the plant travels down the supply duct 2. A standard baffle is mounted at the inlet of the filter to break up the air flow

2

Nederman LLC • 800 532 5286 • www.nederman.com • FMK.0211.1

Uses Cassette type filters

Applications:

Bench Grinding • Cutting • Bagging Operations • Batch Feeders • Conveyors • Mixing

• Cassette offers ample filter area and lasts longer than cartridge

• Compact design

• Compressed air cleaning

• Various filtration medias available

• Galvanized construction for indoor or outdoor placement

• Integral or remote mounted fans available

Features

The FMK (1,000-6,000 CFM)Suitable for collection of many fine dusts including metal grinding, solid surface and most powders

Page 3: FMK Cassette Filter - Hebron PM · 2017. 10. 5. · from the plant travels down the supply duct 2. A standard baffle is mounted at the inlet of the filter to break up the air flow

3

Nederman LLC • 800 532 5286 • www.nederman.com • FMK.0211.1

How It Works

3

5

2

6

1

7

4

6

4

7

4

3

9

8

8

9

4

10

...during normal operation 1. During normal operation, the dust laden air from the plant travels down the supply duct 2. A standard baffle is mounted at the inlet of the filter to break up the air flow and direct the dust downward into the hopper section while protecting the filter media from abrasive dusts

3. The lighter dust collects on the outside of the filter cassettes as clean air passes through to the inside of each filter tube . Finally, the clean air travels through the air handling fan where it could be returned to the plant or exhausted outdoors

4. The heavier dust settles in the hopper section where it can be discharged into a metal bin or through a rotary air lock

1

2

3

4

6

5

3

7

...while cleaning 1. The FMK utilizes a Delta-P gauge to control the compressed air cleaning. In essence, the filter cleans itself when it needs to! 2. A compressed air line must be connected to one end of the compressed air manifold

3. A solenoid valve opens to allow compressed air from the compressed air manifold into the jet tubes . The jet tubes are aligned above EACH row in the filter cassette

4. The downward blast blows the dust off the filter cassette (from the inside out) where it settles into the hopper section to be collected in the metal bin or discharged through a rotary air lock

98

810

43

7

Page 4: FMK Cassette Filter - Hebron PM · 2017. 10. 5. · from the plant travels down the supply duct 2. A standard baffle is mounted at the inlet of the filter to break up the air flow

AUTO

ON/OFF

45”

‘A’

25 5/8”

‘C’

‘B’

12”

ON/OAUTOFF

45”

26”

51 1/4”

‘A’

‘B’

‘C’

MODELNUMBER

NO. OFCASSETTES

AND SIZE

FILTERMEDIA(FT2)

MAX AIRVOLUME

(CFM)

‘A1’WITH SMALL BIN

(14gAL.)

‘A2’WITH LARgE BIN

(28gAL.)

‘A3’WITH LARgE DRUM

(55gAL.)OR AIR-LOCK

‘B’ ‘C’STANDARD

FANARRgT.

FMK 2E/42

(4 ROW)160 1,000 8’ - 6” 9’ - 8” 11’ - 9” 4’ - 9” 1’ - 8”

FM 6163HP

FMK 2E/62

(6 ROW)237 1,500 8’ - 6” 9’ - 8” 11’ - 9” 4’ - 9” 1’ - 9”

FM 6205HP

FMK 4E/44

(4 ROW)320 2,000 8’ - 6” 9’ - 8” 11’ - 9” 4’ - 9” 1’ - 9”

FM 6205HP

FMK 4E/64

(6 ROW)474 3,000 8’ - 6” 9’ - 8” 11’ - 9” 4’ - 9” 2’ - 0”

FM 6257.5HP

4

Nederman LLC • 800 532 5286 • www.nederman.com • FMK.0211.1

Unit Specifications

FMK 2E FMK 4E

Unit shown with 14 gallon bin

Unit shown with 28 gallon bin

Page 5: FMK Cassette Filter - Hebron PM · 2017. 10. 5. · from the plant travels down the supply duct 2. A standard baffle is mounted at the inlet of the filter to break up the air flow

FOTUA O/NO

F

51"

45" 76 7/8"

'A'

'B'

'C'

T/OOUA

NOFF

‘C’

‘B’

‘A’

102 1/2”

51”

45”

MODELNUMBER

NO. OFCASSETTES

AND SIZE

FILTERMEDIA(FT2)

MAX AIRVOLUME

(CFM)

‘A1’WITH SMALL BIN

(14gAL.)

‘A2’WITH LARgE BIN

(28gAL.)

‘A3’WITH LARgE DRUM

(55gAL.)OR AIR-LOCK

‘B’ ‘C’

FMK 6E/46

(4 ROW)480 3,000 8’ - 6” 9’ - 8” 11’ - 9” 4’ - 9” 2’ - 0”

FMK 6E/66

(6 ROW)711 4,500 8’ - 6” 9’ - 8” 11’ - 9” 4’ - 9” 3’ - 2”

FMK 8E/48

(4 ROW)640 4,000 8’ - 6” 9’ - 8” 11’ - 9” 4’ - 9” 2’ - 9”

FMK 8E/68

(6 ROW)948 6,000 8’ - 6” 9’ - 8” 11’ - 9” 4’ - 9” 3’ - 2”

5

Nederman LLC • 800 532 5286 • www.nederman.com • FMK.0211.1

FMK 6E FMK 8E

Unit shown with airlock & damper discharge

Unit shown with 55 gallon drum

Page 6: FMK Cassette Filter - Hebron PM · 2017. 10. 5. · from the plant travels down the supply duct 2. A standard baffle is mounted at the inlet of the filter to break up the air flow

20

19

18

17

16

15

14

13

12

11

10

9

8

7

60 500 1000 1500 2000 2500 3000 3500

1000 2000 3000 4000 5000 6000 7000 8000

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

6

Nederman LLC • 800 532 5286 • www.nederman.com • FMK.0211.1

Fan Curves

FM 616-3 HPFM 620-5 HP

FM 625-7.5 HP

FM 825-10 HPFM 828-15 HP

FM 831-20 HP

Air Volume - CFM

Air Volume - CFM

Stat

ic P

ress

ure

in. W

GSt

atic

Pre

ssur

e in

. WG

FM Fan Performance Curves 3HP - 7.5HP

FM Fan Performance Curves 10HP - 20HP

Page 7: FMK Cassette Filter - Hebron PM · 2017. 10. 5. · from the plant travels down the supply duct 2. A standard baffle is mounted at the inlet of the filter to break up the air flow

7

Nederman LLC • 800 532 5286 • www.nederman.com • FMK.0211.1

Options

14 gallon quick release bin

28 gallon quick release bin with wheels NRS3 rotory air-lock NFSU3 counter

balanced dump valve

Fan outlet elbow

Fan outlet damper

Silencer Explosion panelFan outlet transition

55 gallon drum assembly

Page 8: FMK Cassette Filter - Hebron PM · 2017. 10. 5. · from the plant travels down the supply duct 2. A standard baffle is mounted at the inlet of the filter to break up the air flow

Indonesia (Distributor Authorized) : PT. Hebron Perkasa Mandiri Tel: +62 (21) 78893826 ; 70803527 Fax: +62 (21) 78888270 E-mail: [email protected] www.hebronpm.com