103
© Copyright 2007, Fluke Corporation. All rights reserved. Printed in Italy 01/07 Data subject to alteration without notice. Pub_ID: 11172-eng Rev. 01 Fluke Corporation P.O. Box 9090 Everett, WA USA 98206 Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446 -5116 In Europe/M-East/Africa +31 (0)40 2 675 200 or Fax +31 (0)40 2 675 222 In Canada (905) 890-7600 or Fax (905) 890-6866 From other countries +1 (425) 446 -5500 or Fax +1 (425) 446 –5116 Visit us on the worldwide web at: www.fluke.eu www.fluke.com Fluke (UK) Ltd. 52 Hurricane Way Norwich Norfolk NR6 6JB United Kingdom Tel.: (020) 7942 0700 Fax: (020) 7942 0701 E-mail: [email protected] Visit us on the worldwide web at: www.fluke.co.uk Test Tools Catalog 2007 Test Tools Catalog Fluke. Keeping your world up and running. TM Digital Multimeters Clamp Meters Electrical Testers Insulation Testers Earth Ground Testers Installation Testers Portable Appliance Testers Indoor Air Quality Tools Digital Thermometers Thermal Imagers Power Quality Tools ScopeMeter ® Test Tools Field Calibrators EX Test Tools Accessories 2007

Fluke 2007

Embed Size (px)

Citation preview

Page 1: Fluke 2007

© Copyright 2007, Fluke Corporation. All rights reserved.Printed in Italy 01/07Data subject to alteration without notice.Pub_ID: 11172-engRev. 01

Fluke CorporationP.O. Box 9090Everett, WA USA 98206

Fluke Europe B.V.P.O. Box 11865602 BD EindhovenThe Netherlands

For more information call:In the U.S.A. (800) 443-5853or Fax (425) 446 -5116In Europe/M-East/Africa +31 (0)40 2 675 200or Fax +31 (0)40 2 675 222In Canada (905) 890-7600or Fax (905) 890-6866From other countries +1 (425) 446 -5500or Fax +1 (425) 446 –5116

Visit us on the worldwide web at:

www.fluke.euwww.fluke.com

Fluke (UK) Ltd.52 Hurricane WayNorwichNorfolkNR6 6JBUnited KingdomTel.: (020) 7942 0700Fax: (020) 7942 0701E-mail: [email protected]

Visit us on the worldwide web at:

www.fluke.co.uk

Te

st T

oo

ls C

ata

log

20

07

Test Tools Catalog

Fluke. Keeping your worldup and running.TM

Digital Multimeters

Clamp Meters

Electrical Testers

Insulation Testers

Earth Ground Testers

Installation Testers

Portable Appliance Testers

Indoor Air Quality Tools

Digital Thermometers

Thermal Imagers

Power Quality Tools

ScopeMeter® Test Tools

Field Calibrators

EX Test Tools

Accessories

2007

Page 2: Fluke 2007

Contents

Fluke web and electronic newsletter..............................................New from Fluke ..................................................................................

Application/background articles ..................................................Fluke where safety is built-in......................................................Why true-RMS................................................................................Adjustable speed drives ................................................................Basic electrical testing ..................................................................

Digital Multimeters ..........................................................................DMM Selection Guide ....................................................................Fluke Combo Kits ..........................................................................180 Series Digital Multimeters ....................................................80 Series V Digital Multimeters ..................................................170 Series Digital Multimeters ....................................................110 Series II Digital Multimeters ................................................27/77IV Digital Multimeters ........................................................88V Automotive Meter ..................................................................8845A/8846A Precision Multimeters..........................................

Clamp Meters and Electrical Testers............................................330 Series/902 Clamp Meters ....................................................320 Series Clamp Meters..............................................................360 Leakage Clamp Meter ..........................................................T50/ T100 Series Voltage/Continuity Testers ............................T5/1AC-II/LVD1/LVD2 Electrical Testers ....................................9040/9062 Phase Rotation Indicators........................................2042 Cable Locator ......................................................................

Insulation Testers/Earth Ground Testers ....................................Insulation Tester Selection Guide ................................................1550B MegOhmMeter....................................................................1577/1587 Insulation Multimeters ..............................................1587 Combo Kits ............................................................................1503/1507 Insulation Testers ......................................................1620 Series Earth Ground Testers ..............................................1630 Earth Ground Clamp Meter ................................................

Installation Testers/Portable Appliance Testers ......................1650 Series Multifunction Installation Testers ..........................6000 Series Portable Appliance Testers ....................................

Indoor Air Quality Tools ..................................................................975 Air Meter..................................................................................983 Particle Counter......................................................................971 Temperature Humidity Meter ................................................

Digital Thermometers ......................................................................570 Series Precision Infrared Thermometers ..........................60 Series Infrared Thermometers................................................561 Multipurpose Thermometer ..................................................50 Series Thermometers ..............................................................

Thermal Imagers ..............................................................................Ti Series Thermal Imagers............................................................Ti20 Thermal Imager ....................................................................Ti40/Ti50 Series Flexcam® Thermal Imagers ............................

Power Quality Tools..........................................................................Power Quality Selection Guide ....................................................345 Power Quality Clamp Meter..................................................43B Single-phase Power Quality Analyzer ................................430 Series Three-phase Power Quality Analyzers ..................VR101S Voltage Event Recorder System ....................................1735 Power Logger........................................................................1740 Series Power Quality Loggers ............................................1760 Power Quality Recorder ......................................................

ScopeMeter® Test Tools ..................................................................ScopeMeter Selection Table ........................................................190 Series ScopeMeters................................................................120 Series ScopeMeters ................................................................ScopeMeter Accessories ................................................................

Field Calibrators................................................................................Field Calibrator Selection Guide ..................................................740 Series Documenting Process Calibrators ............................725/725Ex/726 Multifunction Process Calibrators ..................724 Temperature Calibrator ........................................................712/714 Temperature Calibrators ................................................717/718/718Ex Pressure Calibrators ............................................705/707/707Ex/715 Loop Calibrators ........................................771 Process mA Clamp Meter ......................................................787/789 ProcessMeters ................................................................Field Calibrators Accessories........................................................

ATEX Certified Test Tools................................................................A brief look at ATEX ......................................................................Fluke intrinsically safe tools ........................................................

General Accessories ........................................................................Test leads, Probes & Clips ............................................................Current Clamps ..............................................................................Temperature Accessories ..............................................................Cases and Holsters ........................................................................Automotive Accessories ................................................................Other Accessories ..........................................................................Fuse and Warranty Information ..................................................Product Quick Find List..................................................................Other Catalogs ................................................................................

See page 100 for a Product Quick FindList per model number

Fluke. Keeping your worldup and running.TM

12-4

56-78910

11121314151617181920

2122232425262728

2930313233343536

3738-3940-41

42434445

4647484950

51525354-55

5657585960-6162636465

666768-697071

7273747576777879808182

838485

8687-8990-9192-9394-959697-9899100101

Page 3: Fluke 2007

Fluke Web and Electronic Newsletter

Fluke web

Complete informationThe most complete and in-depth resource forinformation on Fluke’s products and servicesincluding:• Product information• Interactive selection guides• Virtual product demonstrations• Extended specifications• Application notes• Product manuals• Service information• What’s new• Promotions• Prices• Where to buy• Distributor and sales office locations

Find information fast To quickly find more information on Flukeproducts, use the “Search by model” box in thetop left corner of our web pages. All you have to do is type in the model number.

Europe: www.fluke.euUK: www.fluke.co.ukIE: www.fluke.ieWorldwide: www.fluke.com

Electronic Newsletter

E-Test-it! is Fluke’s regular newspublication for professional test toolusers. It is electronically available 6times per year. You will be the first tohear about:

• New Fluke products • The latest actions and promotions from Fluke • How to get more out of Fluke tools • How to use Fluke tools better in your

application• Exclusive offers, promotions and discounts on

Fluke Merchandizing• Exclusive offers on Fluke ex-demo equipment

E-Test-it! is free of charge. If at any point intime you do not want to receive E-Test-it!anymore, you can unsubscribe with a simplemouse click. E-Test-it! is small in size (onaverage about 12 KB) and does not fill up yourmailbox or take long to download.

Try it now and sign-up for your FREE e-Test-it! subscription.Go to the Fluke web site and fill in theon-line subscription form.

Fluke web sites are available in all countries around the world and in 14 different languages.

1

Page 4: Fluke 2007

New from Fluke

The Fluke 110 Series comprises four true-RMS digital multimeters eachdesigned for specific users, so one is sure to match your needs. The compact instruments offer convenient one-handed operation andfeature a backlit display with large, easy-to-read digits.

See also page 17.

Fluke 110 Series Digital Multimeters

Fluke 8845A/8846A Precision Multimeters

This multimeter has significant improvements over Fluke’s original 70 Series with more measurement functions, conformance to the latestsafety standards, and a much larger display that’s easier to view.

See page 18.

Fluke 77-IV Digital Multimeter

The Fluke 360 is ideal for non-invasive checks of insulation resistance. The unique jaw design eliminates the influence of

adjacent current conductors.

See page 24.

Fluke 360 AC Leakage Clamp Meter

The Fluke 1630 combines the two current clamps needed to perform thestakeless ground loop test in one compact and easy to use instrument.

See page 36.

Fluke 1630 Earth Ground Clamp Meter

The Fluke 1620 Series Earth Ground Testers not only measure groundresistance using the classic “fall of potential test” but also enable timesaving testing using the “selective” and “stakeless” methods.

See also page 35.

Fluke 1620 Series Earth Ground Testers

The Fluke 8845A/8846A 6.5 digit precisionmultimeters have the precision and versatility to

handle your most demanding measurements on thebench or in a system.

See also page 20.

2

Page 5: Fluke 2007

New from Fluke

The Fluke IR Flexcams give you the industry’s largest and sharpestthermal images. The FT models feature the innovative IR-Fusion™technology to better pinpoint impending problems.

See also pages 54 and 55.

Fluke Ti40/Ti50 Series IR Flexcam® Thermal Imagers

The Fluke 345 combines a current clamp, power quality meter,oscilloscope and data logger for troubleshooting power disturbances in

‘noisy’ electrical environments.

See page 58.

Fluke 345 Power Quality Clamp Meter

For troubleshooting disturbances, characterizing power quality, andconducting power load studies, the Class A compliant Fluke 435provides expanded memory and user-configurable logging for detailedcapture of parameters at user-defined intervals.

See pages 60 and 61.

Fluke 435 Power Quality Analyzer

The Fluke 1735 verifies electrical system capacity and quantifies energyconsumption before and after installation of energy-saving devices. It also

captures harmonics and voltage events for up to 45 days.

See page 63.

Fluke 1735 Power Logger

Compact Fluke 1740 Series loggers are ideal leave-behind tools forcapturing intermittent disturbances and logging power parameters for upto 85 days according to EN50160.

See page 64.

Fluke 1740 Series Power Quality Loggers

The fully Class A compliant Fluke 1760 provides detailed simultaneousrecording of several power parameters according to EN 50160 for

extended periods of time.

See page 65.

Fluke 1760 Power Quality Recorder

3

Page 6: Fluke 2007

New from Fluke

The lightweight and portable Fluke 561 combines an infraredthermometer and a contact thermometer, with an optimal temperaturerange for a variety of inspection tasks.

See page 49.

Fluke 561 Multipurpose Thermometer

Fluke 975 AirMeter

The Fluke 902 expands the existing line of rugged Fluke clamp metersby adding temperature and capacitance measurement capabilities idealfor heating, ventilation and air conditioning system inspections.

See page 22.

Fluke 902 True RMS Clamp Meter

With the Fluke 771 you no longer need to lift a wire from a terminal(break the loop) to measure 4-20 mA which has a direct impact on your

maintenance time.

See page 80.

Fluke 771 Process mA Clamp Meter

The i30 and i30s AC/DC Current Clamps use advanced Hall Effecttechnology for accurate non-intrusive measurements of AC and DC

currents up to 30A.

See page 91.

i30/i30s Current Clamps

The i3000flex is an AC current clamp using the Rogowski principle. Itcan be used to measure currents up to 3000A. The flexible measuringhead allows quick and easy installation in hard to reach areas.

See page 90.

i3000flex Current Clamp

The Fluke 975 simultaneously measures, logs, anddisplays temperature, humidity, air flow and velocity,as well as CO2 and CO levels for complete air quality

monitoring.

See page 43.

4

Page 7: Fluke 2007

As part of our commitment to supporting you in your work we domore than just design and manufacture rugged and versatile test tools:we also provide detailed background information to help you choosethe right instrument and offer advice on using it effectively and safely.You can download all Application Notes from our web site.

Application/background articles

5

Page 8: Fluke 2007

Figure 1. Understanding categories: location

Overvoltage installation categories. IEC 61010-1 applies to low-voltage (< 1000V) test equipment

Fluke: Where safety is built in

Who Develops Safety Standards?The IEC (International ElectrotechnicalCommission) develops international generalstandards for safety of electrical equipmentfor measurement, control and laboratory use.IEC61010-1 is used as the basis for thefollowing national standards:

• US ANSI/ISA-S82.01-94• Canada CAN C22.2 No.1010.1-92• Europe EN61010-1:2001

Overvoltage Installation CategoriesIEC61010-1 specifies categories ofovervoltage based on the distance the pieceof equipment is from the power source (see Fig. 1 and Table 1) and the naturaldamping of transient energy that occurs in anelectrical distribution system. Higher categoriesare closer to the power source and requiremore protection. Within each installation category there arevoltage classifications. It is the combination ofinstallation category and voltage classificationwhich determines the maximum transientwithstand capability of the instrument.

IEC 61010 test procedures take into accountthree main criteria: steady-state voltage,peak impulse transient voltage and sourceimpedance. These three criteria together willtell you a multimeter’s true voltage withstandvalue.

Within a category, a higher working voltage”(steadystate voltage) is associated with ahigher transient, as would be expected. Forexample, a CAT III 600 V meter is tested with 6000 V transients while a CAT III 1000 Vmeter is tested with 8000 V transients. So far, so good. What is not as obvious is thedifference between the 6000 V transient forCAT III 600 V and the 6000 V transient forCAT II 1000 V. They are not the same.

As distribution systems and loadsbecome more complex, thepossibilities of transient overvoltagesincrease. Motors, capacitors andpower conversion equipment such asvariable speed drives can be primegenerators of spikes. Lightningstrikes on outdoor transmission linesalso cause extremely hazardoushigh-energy transients. If you’retaking measurements on electricalsystems, these transients are“invisible” and largely unavoidablehazards. They occur regularly onlow-voltage power circuits, and canreach peak values in the manythousands of volts. To protect youagainst transients, safety must bebuilt into the test equipment.

This is where the source impedance comesin. Ohm’s Law (Amps = Volts/Ohms) tells usthat the 2 test source for CAT III has sixtimes the current of the 12 test source forCAT II. The CAT III 600 V meter clearly offerssuperior transient protection compared to theCAT II 1000 V meter, even though its so-called “voltage rating” could be perceived asbeing lower. See Table 2.

Independent testing is the key tosafety complianceHow can you tell if you’re getting a genuineCAT III or CAT II meter? Unfortunately it’s notalways that easy. It is possible for amanufacturer to self-certify that its meter isCAT II or CAT III without any independentverification. The IEC (InternationalElectrotechnical Commission) develops andproposes standards, but it is not responsiblefor enforcing the standards. Look for thesymbol and listing number of an independenttesting lab such as UL, CSA, VDE, TÜV orother recognized approval agency.

These symbols can only be used if the productsuccessfully completed testing to the agency’sstandard, which is based on national/-international standards. UL 3111, for example,is based on EN61010-1. In an imperfect world,this is the closest you can come to ensuringthat the meter you choose was actually testedfor safety.

Table 1

Overvoltage category In brief ExamplesCAT IV Three-phase at utility connection, • Refers to the “origin of installation”; i.e., where low-voltage connection is made to utility power.

any outdoor conductors • Electricity meters, primary overcurrent protection equipment.• Outside and service entrance, service drop from pole to building, run between meter and panel.• Overhead line to detached building, underground line to well pump.

CAT III Three-phase distribution, including • Equipment in fixed installations, such as switchgear and polyphase motors. single-phase commercial lighting • Bus and feeder in industrial plants.

• Feeders and short branch circuits, distribution panel devices.• Lighting systems in larger buildings.• Appliance outlets with short connections to service entrance.

CAT II Single-phase receptable • Appliance, portable tools, and other household and similar loads.connected loads • Outlet and long branch circuits.

• Outlets at more than 10 meters (30 feet) from CAT III source.• Outlets at more than 20 meters (60 feet) from CAT IV source.

CAT I Electronic • Protected electronic equipment.• Equipment connected to (source) circuits in which measures are taken to limit transient

overvoltages to an appropriately low level.• Any high-voltage, low-energy source derived from a high-winding resistance transformer,

such as the high-voltage section of a copier.

6

Page 9: Fluke 2007

7

Fluke: Where safety is built in

Table 2

Overvoltage Working Voltage Peak Impulse Test SourceInstallation (DC or AC RMS Transient ( = V/A)Category to ground) (20 repetitions)

CAT I 600 V 2500 V 30 Ohm sourceCAT I 1000 V 4000 V 30 Ohm sourceCAT II 600 V 4000 V 12 Ohm sourceCAT II 1000 V 6000 V 12 Ohm sourceCAT III 600 V 6000 V 2 Ohm sourceCAT III 1000 V 8000 V 2 Ohm sourceCAT IV 600 V 8000 V 2 Ohm source

Select the right test tool:• Choose a test tool rated to the highest

category and voltage for which it couldpossibly be used (most often 600 or 1000 volt CAT III and/or 600 volt CAT IV).

• Look for the category and voltage markingnear the recessed input connectors of yourtest tool and a “double insulated” symbolon the back.

• Verify your test tool has been tested andcertified by two or more independent testinglaboratories, such as UL in the United Statesand VDE or TüV in Europe by looking for thesymbols of these agencies on (the back of)your test tool.

• Make sure that the test tool is made of ahigh-quality, durable non-conductivematerial.

• Check the manual to verify that the ohms,continuity and capacitance circuits areprotected to the same level as the voltagetest circuit, to reduce hazards when the testtool is used incorrectly in ohms, continuityor capacitance mode (if applicable).

• Verify that the test tool has internalprotection to prevent instrument damagewhen voltage is incorrectly applied to anamperage measurement function (if applicable).

• Make sure that the amperage and voltage ofyour test tool’s fuses meets specifications.Fuse voltage must be as high or higher thanthe test tool’s voltage rating.

• Be sure to use test leads that have:- Shrouded connectors- Finger guards and a non-slip surface- Category ratings that equal or exceed

those of the test tool- Double insulation (look for the symbol)- A minimum of exposed metal on the

probe tips

Inspect and test your test tool:• Check for a broken case, worn test leads or

a faded display.• Make sure the batteries still deliver sufficient

power to get reliable readings. Many testtools have a low battery indicator on thedisplay.

• Check the test leads resistance for internalbreaks while moving the leads around (good leads measure 0.1-0.3 Ohm).

• Use the meter’s own test capability to ensurethat the fuses are in place and working right(see manual for details).

Apply the appropriate workingpractices when measuring on livecircuits:• Hook on the ground clip first, then make

contact with the hot lead. Remove the hotlead first, the ground lead last.

• Use the three-point test method, especiallywhen checking to see if a circuit is dead.First test a known live circuit. Second, testthe target circuit. Third, test the live circuitagain. This verifies that your test tool workedproperly before and after the measurement.

• Hang or rest the test tool if possible. Try toavoid holding it in your hands, to minimizepersonal exposure to the effects of transients.

• Use the old electrician’s trick of keepingone hand in your pocket. This lessens thechange of a closed circuit across your chestand through your heart.

Safety is everyone’s responsibilitybut ultimately it is in your hands. No tool by itself can guarantee yoursafety when working with electricity.It’s the combination of the right toolsand safe work practices that givesyou maximum protection. Here are afew tips to help you in your work:

Make sure you always comply with (local)regulations.

Work on de-energized circuits wheneverpossible. Use proper lock-out/tag-out procedures. If theseprocedures are not in place or enforced, assumethat the circuit is live.

Use protective gear when working onlive circuits:

• Use insulated tools• Wear safety glasses or a face shield• Wear insulated gloves, remove watches or

jewelry• Stand on an insulated mat• Wear flame resistant clothing, not ordinary

work clothes

Use protective equipment such as safety glassesand insulated gloves

Transient test values for overvoltage installation categories. (50 V/150 V/300 V values not included)

Use meters with these markings:1000 V CAT III or 600 V CAT IV

For more information or to request the Electrical Safety DVD go to: United Kingdom: www.fluke.co.uk/safetyIreland: www.fluke.ie/safetyE-Europe/Middle-East/Africa: www.fluke.nl/safety_ex

Page 10: Fluke 2007

Why True RMS ?

Can you trust your meter reading ?

Measuring accurately is a difficult job intoday’s industrial plants and offices. More and more personal computers, adjustablespeed drives and other types of equipmentthat draw current in short pulses rather thanat a steady level come on line every day.Equipment like this can cause the readings ofconventional average-responding meters tobe at least inaccurate. If you have everexperienced blown fuses without any clearcause, then maybe your meter is to blame.

Average-respondingWhen people talk about values of AC currents,they normally mean the effective heating orRMS (Root Mean Square) value of the current.This value is equivalent to a DC current withthe same heating value as the AC currentwhich is being measured. The most commonway to measure this RMS value with a meteris to rectify the AC current, determine theaverage value of this rectified signal and thenmultiply the result by a factor 1.1. This factorrepresents the constant relationship betweenthe average and RMS values of a perfectsinewave. However, if the waveform is not aperfect sinewave, this relationship no longerapplies. This is why average respondingmeters often give incorrect readings whenmeasuring currents in today’s power systems.

Linear and non-linear loadsLinear loads - consisting purely of resistors,coils and capacitors - always draw asinewave current, so there is no measurementproblem (see fig.1). But non-linear loads likeadjustable frequency drives and officeequipment power supplies, draw distortedcurrent waveforms (see fig 2 and 3).Measuring the RMS value of these distortedcurrents with an average-responding metercould give you readings which are up to50% too low (see fig. 4), leaving youwondering why your 14A fuse blowscontinuously while the current according toyour meter is only 10A.

True RMSTo measure such distorted current waveforms,you could first check the waveform with awaveform capturing device, and only use anaverage responding meter if the waveform isa perfect sinewave. Or alternatively you could take no chancesby always using a true RMS meter. A modern true RMS meter uses an electronicmeasurement technique to provide you withthe real effective value of an AC current, nomatter if the waveform of the current is aperfect sinewave or a distorted waveform.As long as it is within the meter’s crest factorand bandwidth specification.

What about voltage measurements?What is valid for current measurements intoday’s power systems also is true for voltagemeasurements in many industrial andelectronic applications. Often voltagewaveforms are not perfect sinewaves whichwill result in incorrect readings with averageresponding meters. Therefore it isrecommended to always use True-RMSresponding meters for both voltage and currentmeasurements.

Fig 1. Current waveform of a linear load.

Fig 2. Current waveform of a non-linear load.

Fig 3. Current waveform of a PC.

Type Of Measuring Response To Response To Response ToMeter Circuit Sine Wave Square Wave Distorted Wave

Average- Multiplies Correct 10% high Up to 50% lowresponding rectified

average by 1.1

True-RMS- RMS-calculating Correct Correct Correctresponding converter

calculatesheating value

Fig 4. Comparing the Performance of Average-Responding and True-rms Responding Meters.True RMS

8

Page 11: Fluke 2007

Troubleshooting Adjustable Speed Drives

The Pulse Width Modulated (PWM)signalThe basic problem comes from the pulsewidth modulated, high output voltage of thedrive (see figure 1).

Many instruments have difficulties in handlingthis complex signal:• The PWM signal is difficult to measure

(this has been especially true for DMMs)• The signal generates high rf noise, making

readings unstable• Safety norms require CAT III or even CAT IV

rated measurement equipment.

Fluke has several instruments that now makethe troubleshooting of ASDs easy:

Fluke 87V Digital MultimeterMany of today’s true rms digital multimetershave bandwidths up to 20 kHz or more. So they respond not only to the fundamentalcomponent, which is what the motorresponds to, but also to all the high frequencycomponents generated by the PWM drive. If the DMM isn’t shielded from high frequencynoise, the drive controller’s high noise levelsmake the measurement discrepancies evenmore extreme.

Fluke’s new 87V solves this. This new CAT IVrated meter has special shielding and apatented low pass filter that takes accuratemotor measurements. The instrument helpstroubleshoot the basic performance of anASD by measuring the proper voltage andfrequency on the motor terminals with thedrive display, calculating the Volt-Herz product,measuring the DC Bus ripple, and more.

Fluke ScopeMeter® 190 SeriesThe Fluke 190 Series ScopeMeters are idealfor further analyzing problems with pulse-width-modulated variable speed drives. They feature a special Vpwm function thatmeasures the voltage actually applied tomotor whilst simultaneously measuring thefrequency.

The ScopeMeter also provides Connect-and-View™ triggering which automatically displaysa stable picture of the real signal.

Adjustable Speed Drives (ASDs)deliver huge benefits to industry.They save energy, enable moreprecise process control and helpmotors and equipment last longer.However ASDs also cause realdifficulties for service engineers.The electrical troubleshooting of a drive can be difficult since mostmeasurement equipment is notdesigned to handle the complexoutput signals of the drive.

Other Fluke toolsMany ASDs operate in an industrialenvironment, where large loads and loadchanges can result in poor power quality.Often, the performance of ASDs may beimpaired by this. Fluke’s range of powerquality products helps to locate and preventproblems in power distribution systems tokeep ASDs running smoothly.

Measuring current is very important whenservicing ASDs and motors. One of the morecommon tools used for this is the currentclamp. However, many ASDs are located inareas needing CAT IV safety rated equipment.Fluke’s new i400s and i400 current clampsare the first to be CAT IV rated. The 400 Arange and small overall size also make themideal for measuring ASD and motor currents.

For more information download theApplication Notes from our web site orrequest a copy from our local sales office.

There are three Application Notes available: • Multimeter measurements on adjustable

speed drives using the Fluke 87V DigitalMultimeter.

• Measuring variable speed-motor drive outputvoltage with a Fluke ScopeMeter® 190 Series.

• Troubleshooting in 3-phase power networkswith the Fluke 430 Series Power QualityAnalyzers.

Figure 1. Motor drive output measured using theFluke ScopeMeter 199C

Figure 2. Output voltage reading without usingthe low pass filter.

Figure 3. Output voltage reading with low passfilter enabled.

9

Page 12: Fluke 2007

Basic electrical installation testing

Table 1

European equivalents of IEC 60364 (6.61)

Austria ÖVE/ÖNORM E8001Belgium A.R.E.I. / R.G.I.E.Denmark Stærkstrømbekendtgørelsen 6Finland SFS 6000France NF C 15-100Germany DIN VDE 0100Italy CEI 64-8Netherlands NEN 1010Norway NEK 400Portugal HD 384Spain UNE 20460Sweden SS 4364661 / ELSÄK-FS

1995:5Switzerland NIN / SN SEV 1000UK BS 7671 / 16th Edition IEE

Wiring Regulations

It is therefore important to have suitabletest tools for carrying out the stringent testsimposed by the InternationalElectrotechnical Commission (IEC) and theEuropean Committee for ElectrotechnicalStandardization (CENELEC). IEC 60364, andits various associated national equivalentstandards that are published throughoutEurope (see table 1), specifies therequirements for fixed electricalinstallations in buildings. Section 6.61 ofthis standard describes the requirementsfor the verification of the compliance of theinstallation with IEC 60364.

The basic requirements of IEC60364.6.61Many electrical contractors may already befamiliar with IEC 60364.6.61 or its nationalequivalents. It states that verification of theinstallation shall be carried out in thefollowing sequence:1. Visual inspection2. Testing of the following:

• continuity of protective conductors;• insulation resistance;• protection by separation of circuits;• floor and wall resistance;• automatic disconnection of supply;

- measurements of earth electroderesistance

- measurements of fault loopimpedance

- testing RCDs• polarity;• functional performance

To test the protective measures as describedabove, IEC 60364.6.61 refers to the IEC / EN 61557.

The basic requirements of IEC/EN 61557The European Norm EN 61557 addressesthe requirements for test equipment used ininstallation testing. It consists of generalrequirements for test equipment (part 1),specific requirements for combinedmeasuring equipment (part 10) and coversthe specific requirements for measuring/-testing:

1. Insulation resistance (part 2)2. Loop impedance (part 3)3. Resistance of the earth connection

(part 4)4. Resistance to earth (part 5)5. RCD performance in TT and TN

systems (part 6)6. Phase sequence (part 7)7. Insulation monitoring devices for IT

systems (part 8)

The Fluke 1650 Series multifunctioninstallation testers are measuring equipmentas described in part 10 of EN 61557 andthe three different models in the seriescomply with specific parts of this norm.They are specifically designed to carry outthe tests specified in IEC 60364.6.61, andall local standards/regulations derived fromit, in the safest and most efficient way.They are lightweight, and feature a uniqueergonomic ‘curved’ form that, when carriedby the neck strap, makes operation in thefield more comfortable.

For more information download theApplication Note “Basic ElectricalInstallation Testing” from our website or request a copy from our localsales office. (pub_ID: 10641).

Growing concern for public safety andthe increasing complexity of today’sfixed electrical installations indomestic, commercial and industrialpremises places extra responsibilityon electrical test engineers who arecharged with verifying conformity to today’s stringent internationalstandards.

10

Page 13: Fluke 2007

11

Safety, quality and performance: three words that sum up the benefitsof our extensive range of digital multimeters. From compact first-leveltroubleshooters to ultra smart instruments packed with features.Designed to help you do your job faster, more efficiently and withgreater accuracy, there’s a model for every budget and application.

Digital Multimeters

Page 14: Fluke 2007

12

DMM Selection guide18

918

787

V8

3V

179

177

175

117

116

115

114

77IV

278

8V

78

97

8715

87/1

587T

1577

5000

050

000

2000

06

000

600

06

000

600

06

000

600

06

000

600

06

000

3200

2000

040

0040

006

000

600

0A

C+D

CA

C+D

CA

CA

CA

CA

CA

CA

CA

CA

CA

CA

CA

CA

C0.

025%

0.02

5%0.

05%

0.1%

0.0

9%0.

09%

0.15

%0.

5%0.

5%0.

5%0.

5%0.

3%0.

1%0.

1%0.

1%0.

1%0.

09%

0.2%

100

kHz

100

kHz

20 k

Hz

5 kH

z30

kH

z

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

1000

V10

00 V

1000

V10

00 V

1000

V10

00 V

1000

V6

00 V

600

V6

00 V

600

V10

00 V

1000

V10

00 V

1000

V10

00 V

1000

V10

00 V

10 A

10 A

10 A

10 A

10 A

10 A

10 A

10 A

200

µA10

A10

A10

A10

A1

A1

A40

0 m

A40

0 m

A50

0 M

500

M50

M50

M50

M50

M50

M40

M40

M40

M40

M50

M32

M50

M40

M40

M50

M50

M1

MH

z1

MH

z20

0 kH

z20

0 kH

z10

0 kH

z10

0 kH

z10

0 kH

z50

kH

z50

kH

z50

kH

z10

0 kH

z20

0 kH

z20

kH

z20

kH

z10

0 kH

z50

mF

50 m

F10

mF

10 m

F10

mF

10 m

F10

mF

10 m

F10

mF

10 m

F10

mF

10 m

F10

mF

+13

50 °

C+

1350

°C

+10

90 ºC

+40

0 °C

+40

0 °C

+10

90 ºC

+50

0 ºC

60

dB6

0 dB

500

nS50

0 nS

60

nS6

0 nS

32 n

S6

0 nS

/

/

/-

/-

/

/-

52

/

/

/-

/-

/-

/-

/-

/-

/-

/-

/-

/-

/-

/-

/-

/-

/-

250

µs25

0 µs

250

µs25

0 µs

/

/

/

/

/

/

/

/-

/-

/-

/-

-/

-/

/

-/

-/

/

/

/-

/-

100

/

/-

/

/

/-

/-

/-

/-

/-

/-

/-

/-

/-

/

/-

/

/-

/

/

3

33

3

33

33

1000

V10

00 V

1000

V10

00 V

1000

V10

00 V

1000

V6

00 V

600

V6

00 V

600

V10

00 V

1000

V10

00 V

1000

V10

00 V

1000

V10

00 V

600

V6

00 V

600

V6

00 V

600

V6

00 V

600

V6

00 V

600

V6

00 V

600

V14

1415

1516

1616

1717

1717

1818

1981

8132

32

Bas

ic f

eatu

res

Coun

tsTr

ue R

MS

read

ings

Basi

c D

C ac

cura

cyW

ide

band

wid

thA

uto/

man

ual r

angi

ngM

easu

rem

ents

Volta

ge A

C/D

CCu

rren

t A

C/D

CR

esis

tanc

eFr

eque

ncy

Capa

cita

nce

Tem

pera

ture

dB Cond

ucta

nce

Dut

y cy

cle/

puls

e w

idth

Cont

inui

ty w

ith b

eepe

rD

iode

tes

t4-

20m

A lo

op c

urre

nt a

s %

rea

dout

Mot

or d

rive

mea

sure

men

tR

PM /

Dw

ell

VoltA

lert

™, N

on-c

onta

ct v

olta

ge d

etec

tion

LoZ:

low

inpu

t im

peda

nce

Mic

roam

psIn

sula

tion

test

Num

ber

of v

olta

ge t

est

rang

esD

isp

lay

Dua

l dis

play

Ana

log

barg

raph

Back

light

Dat

a st

orag

e an

d e

xch

ang

eM

in-M

ax r

ecor

ding

/with

tim

e st

amp

Fast

Min

-Max

Dis

play

Hol

d/A

uto

(Tou

ch)

Hol

dR

elat

ive

RS-

232

inte

rfac

e/st

and-

alon

e lo

ggin

gR

eadi

ngs

mem

orie

sO

ther

fea

ture

sSo

urce

4-2

0mA

loop

cur

rent

/24V

loop

sup

ply

Aut

omat

ic s

elec

tion,

AC

/DC

Volts

Rea

l tim

e cl

ock

Smoo

thin

gIn

tegr

ated

hol

ster

Rem

ovab

le h

olst

erCl

osed

cas

e ca

libra

tion

Sepa

rate

bat

tery

/fus

e ac

cess

Aut

omat

ic p

ower

off

Low

bat

tery

indi

catio

nW

arra

nty

an

d s

afet

yLi

fetim

e w

arra

nty/

war

rant

y (y

ears

)In

put

aler

tD

ange

rous

vol

tage

indi

catio

nE

N61

010-

1 CA

T II

EN

6101

0-1

CAT

III

EN

6101

0-1

CAT

IVSe

e ca

talo

g pa

ge

Hig

hes

t ac

cura

cy

Hig

h-e

nd

Indu

stri

alIn

dust

rial

mai

nta

nan

ceEl

ectr

ical

HV

AC

/RFi

eld

Bas

icG

ener

alH

eavy

Aut

o-Lo

op c

alib

rati

onIn

sula

tion

tes

tan

d fi

eld

serv

ice

Serv

ice

Elec

tric

alPu

rpos

edu

tym

otiv

e

Page 15: Fluke 2007

13

Fluke Combo Kits

Ordering InformationFluke 87V/E2 Industrial Electrician

Combo KitFluke 179/MAG2 Kit Industrial Combo KitFluke 179/EDA2 Kit Electronics Combo KitFluke 117/322 Kit Electrician’s Combo KitFluke 189/FVF2 Data Logging Multimeter

and Software Combo Kit

Fluke 87V/E2Industrial ElectricianCombo Kit• Fluke 87V True RMS

Multimeter• TL224 SureGrip™ Silicone

Test Lead Set• TP38 Slim Reach Test Probe

Set (insulated)• AC220 SureGrip™ Alligator

Clip Set• TPAK Magnetic Hanger• 80BK Integrated DMM

Temperature Probe • C35 Soft Meter Case

Fluke 179/MAG2 KitIndustrial Combo Kit• Fluke 179 True RMS

Multimeter• TL224 SureGrip™ Silicone

Test Lead Set• AC220 SureGrip™ Alligator

Clip Set• TP4 Slim Reach Test Probe

Set (4 mm)• TPAK Magnetic Hanger• 80BK Integrated DMM

Temperature Probe• C35 Soft Meter Case• + Maglite flashlight

Save23%

Fluke 179/EDA2 KitElectronics Combo Kit• Fluke 179 True RMS

Multimeter• TL224 SureGrip™ Silicone

Test Lead Set• TL910 Electronic Test Probe

Set• AC280 SureGrip™ Hook Clip

Set• TPAK Magnetic Hanger• 80BK Integrated DMM

Temperature Probe• C35 Soft Meter Case

Save28%

Fluke 117/322 KitElectrician’s Combo Kit• Fluke 117 True RMS Multimeter• Fluke 322 Clamp Meter• TL75 Hard Point Test Lead Set• TPAK Magnetic Hanger• C115 Deluxe carrying case with

shoulder strap

Save15%

Fluke 189/FVF2Data Logging Multimeter andSoftware Combo Kit• Fluke 189 True RMS Multimeter• FVF-SC2 FlukeView Forms

Software• IR189USB USB Cable Adapter• TL71 Test Lead Set• AC72 Alligator Clip Set• 80BK Temperature Thermocouple• BP189 High Capacity Battery

Enclosure• C25 Soft Carrying Case• TPAK Meter Hanging Kit Save

32%

Buy a Combo Kit and save

Save14%

Page 16: Fluke 2007

Fluke 189

Fluke 187

180 SeriesDigital Multimeters

Solve complex problems with advancedmeasurement functions, accuracy and data loggingThe Fluke 189 and 187 are the mostadvanced meters with the features, precisionand accuracy to troubleshoot powerdistribution, industrial automation, processcontrols and electronic and electro-mechanical equipment in the field or onthe bench. Model 189 has a built-in data

logger to record measurements unattendedwithout a PC. Recorded data can be viewedon the 189 or transferred to a PC withoptional FlukeView® Forms software.

Included AccessoriesTL71 silicone test leads, probe holder, two AC72 alligator clips, 4 AA batteries(installed), user manual, calibrationcertificate with measurement data.

Ordering InformationFluke 187 True RMS MultimeterFluke 189 True RMS MultimeterFluke 189/FVF2 Data Logging Multimeter

and Software Combo KitSee page 13

FVF-SC2 FlukeView Forms softwareincluding IR/USB cable

True RMS

On all inputs

C125See page 94

TL910See page 87

TL81ASee page 87

BP189See page 97

TPAKSee page 97

Features

True-RMS measurements

Bandwidth (voltage/current)

Digital display counts (default/selectable)

Multiple display with large digits and backlight, updates 4 times per secondAnalog bargraph segments, updates 40 times per second

Min-Max-Average recording with relative time stamp

Fast Min-Max recording

AutoHOLD® and Relative modes for reference and offsetmeasurementsTemperature readings using optional K-type thermocoupleand adapterAudible continuity and diode test

Duty cycle and pulse width measurements

PC interface for data exchange and closed case calibration

Memory for storing up to 3 days of continues stand-aloneloggingReadings memory (memory locations)

Easy battery and fuse exchange without opening thecomplete caseErgonomic case with integrated protective holster

187 and 189**±(0.025%+5)±(0.4%+40)±(0.15%+2)±(0.75%+5)±(0.05%+2)±(1.0%+10)±(1.0%+5)

±(0.005%+1)±(1%+1°C)± 0.1 dB

Functions Maximum Max. resolutionVoltage DC 1000V 1µVVoltage AC 1000V 1µVCurrent DC 10A 0.01µACurrent AC 10A 0.01µAResistance 500M 0.01

Conductance 500nS 0.01nSCapacitance 50000µF 0.001nFFrequency 1MHz 0.01Hz

Temperature -200°C/+1350°C 0.1°CdBm and dBV -52/+60dB 0.01dB

Accuracies are best accuracies for each function.** 187 and 189 accuracy and resolution are stated for 50.000 counts.

Recommended Accessories

Battery Life: 72 hours typical (alkaline)Size (HxWxD): 203 mm x 100 mm x 50 mm

Weight: 0.545 kgLifetime Warranty

187 189AC, AC+DC AC, AC+DC

100kHz / 100kHz 100kHz / 100kHz

50000 / 5000 50000 / 5000

51-segments 51-segments

250µsec 250µsec

100

Specifications

(Check the Fluke web for detailed specifications)

14

Page 17: Fluke 2007

15

not 87V Ex

80 Series VDigital Multimeters

Included AccessoriesTL75 test leads, AC72 alligator clips, yellowholster (H80M excl. TPAK), 80BK temperatureprobe (87V only), 9 V battery (installed), CD-ROM (user’s manual and technical notes)and operator’s guide.

Ordering InformationFluke 83V MultimeterFluke 87V True RMS MultimeterFluke 87V Ex Intrinsically safe

True RMS multimeterFluke 87V/E2 Industrial Electrician Combo Kit

See page 13

True RMS

Performance and accuracy formaximum industrial productivityThe Fluke 80 Series V have improvedmeasurement functions, troubleshootingfeatures, resolution and accuracy to solvemore problems on motor drives, in plantautomation, power distribution, and electro-mechanical equipment.

The Fluke 87V has a unique function foraccurate voltage and frequency measurementson adjustable speed motor drives and otherelectrically noisy equipment. A built-inthermometer conveniently allows you to taketemperature readings without having to carrya separate instrument. For 87V Ex see alsopage 84 and 85.

Features

True-RMS voltage and current for accurate measurements onnon linear signalsBandwidth (voltage/current)

Digital display counts (default/selectable)

Selectable filter for accurate voltage and frequencymeasurements on motor drivesLarge display with analog bargraph and 2 level bright whitebacklight Auto and manual ranging for maximum flexibility

Built-in thermometer lets you carry one less tool

Peak capture to record transients as fast as 250 µs

Relative mode to remove test lead resistance from low ohmsmeasurementsMin-Max-Average recording with Min/Max Alert to capturevariations automaticallyAutoHOLD® to capture stable readings avoiding noisy signals

Audible continuity, diode test and duty cycle

Input Alert

“Classic” design with new removable holster with built intest lead and probe storageImproved selectable sleep mode for long battery life

Easy battery and fuse exchange without opening thecomplete caseATEX safety rating II 2 G Eex ia IIC T4

83V 87V/87V Ex*Max. resolution Accuracy Max. resolution Accuracy

0.1 mV ±(0.1+1%) 10 µV ±(0.05%+1) 0.1 mV ±(0.5%+2) 10 µV ±(0.7%+2)0.1 µA ±(0.4%+2) 0.01 µA ±(0.2%+2)0.1 µA ±(1.2%+2) 0.01 µA ±(1.0%+2)0.1 ±(0.4%+1) 0.01 ±(0.2%+1)

0.01 nS ±(1.0%+10) 0.001 nS ±(1.0%+10)0.01 nF ±(1.0%+2) 0.01 nF ±(1.0%+2)0.01 Hz ±(0.005%+1) 0.01 Hz ±(0.005%+1)

- 0.1 ºC 1.0%- - 2.2 ºC or 2%

Functions Maximum Range

Voltage DC 1000 VVoltage AC 1000 VCurrent DC 10 A **Current AC 10 A **Resistance 50 M

Conductance 60 nSCapacitance 9999 µFFrequency > 200 kHz

Temperature -200 to 1090 ºC80BK temperature probe - 40 to 260 ºC

On all inputs

83V/87V

Fluke 87V

Battery Life: Over 400 hours typical (alkaline).Size (HxWxD):200 mm x 95 mm x 48 mm

Weight: 0.6 kg83V/87V: Lifetime Warranty87V Ex: One Year Warranty

Recommended Accessories(Not for hazardous zones)

Accuracies are best accuracies for each function.* 87V accuracy is stated for 6.000 counts and resolution for 20.000 counts** 20 A up to 30 seconds

Specifications

(Check the Fluke web for detailed specifications)

83V 87V / 87V Ex

5 kHz 20 kHz

6000 20000 / 6000

87V Ex

C25See page 94

TL238See page 88

i410/i1010See page 91

TPAKSee page 97

L215See page 89

Fluke 83V

Fluke 87V Ex

Page 18: Fluke 2007

170 Series Digital Multimeters

16

Included AccessoriesTest leads with 4 mm lantern tips andprotective cap, installed 9V battery andusers manual. The 179 also includes the80BK temperature probe.

Ordering InformationFluke 175 True RMS MultimeterFluke 177 True RMS MultimeterFluke 179 True RMS MultimeterFluke 179/EDA2 Kit Electronics Combo KitFluke 179/MAG2 Kit Industrial Combo Kit

See page 13

i400See page 90

C90See page 94

TLK-220See page 88

SV225See page 98

i410-i1010See page 91

Versatile meters for field service or bench repair These meters have the features needed to find most electrical, electro-mechanicaland heating and ventilation problems. They are simple to use and have significantimprovements over Fluke’s original 70 Series like, True-RMS, more measurementfunctions, conformance to the latest safetystandards, and a much larger display that’seasier to view.

Features

True-RMS measurements

Digital display counts, updates 4 times per second

Display backlight

Analog bargraph / segments, updates 40 times per second

Auto and Manual ranging

Display Hold and AutoHOLD®

Min-Max-Average recording mode with Min/Max Alert

Temperature readings (bead thermocouple probe included)

Smoothing mode allows filtering of rapidly changing inputs

Audible continuity and diode test

Test lead alert

Unsafe voltage alert warns for voltages above 30V

Low battery indication

Ergonomic case with integrated holster

Easy battery exchange without opening the complete case

Selectable sleep mode preserves battery life

175 177 179

±(0.15%+2) ±(0.09%+2) ±(0.09%+2)

±(1.0%+3) ±(1.0%+3) ±(1.0%+3)

±(1.0%+3) ±(1.0%+3) ±(1.0%+3)

±(1.5%+3) ±(1.5%+3) ±(1.5%+3)

±(0.9%+1) ±(0.9%+1) ±(0.9%+1)

±(1.2%+2) ±(1.2%+2) ±(1.2%+2)

±(0.1%+1) ±(0.1%+1) ±(0.1%+1)

±(1.0%+10)

Functions Maximum Max. resolution

Voltage DC 1000V 0.1mV

Voltage AC 1000V 0.1mV

Current DC 10A 0.01mA

Current AC 10A 0.01mA

Resistance 50M 0.1

Capacitance 10000µF 1nF

Frequency 100kHz 0.01Hz

Temperature -40°C/+400°C 0.1°C

Specifications

(Check the Fluke web for detailed specifications)

Accuracies are best accuracies for each function

True RMS

Recommended Accessories

Battery Life: Alkaline, 200 hrs typicalSize (HxWxD): 190 mm x 85 mm x 45 mm

Weight: 0.42 kgLifetime Warranty

On all inputs

175 177 179AC AC AC

6000 6000 6000

33-segments 33-segments 33-segments

Fluke 179

Fluke 177

Fluke 175

Page 19: Fluke 2007

110 Series Digital Multimeters

17

Included AccessoriesTest leads with 4 mm lantern tips andprotective cap, Holster, installed 9V batteryand users manual

Ordering InformationFluke 114 True RMS MultimeterFluke 115 True RMS MultimeterFluke 116 True RMS MultimeterFluke 117 True RMS MultimeterFluke 117/322 Kit Electricians Combo Kit

C50See page 94

TL223See page 88

MC6See page 98

TPAKSee page 97

The Fluke 110 Series comprises of four true-rmsDMMs each designed for specific users, so one is sure to match your needs. The compactinstruments offer convenient one-handedoperation and feature a backlit display with large, easy-to-read digits.

Fluke 117 Electrician’s Multimeter withNon-Contact VoltageFor electricians working in commercial and non-commercial premises (like hospitals and schools),the 117 is recommended. It includes extras likenon-contact voltage detection to help get the jobdone faster and safer.

Fluke 116 Multimeter with temperatureand microampsThe 116 is for heating, ventilation and airconditioning (HVAC) engineers. It includestemperature measurement and microamp currentranges to quickly troubleshoot HVAC problems.

Fluke 115 Multimeter for field servicetestingAn everyday multimeter for technicians, the 115is optimized for electrical and electronic testing infield service, industrial, and applications wheremore than basic functionality (such asmeasurement of ac/dc current) simplifies working.

Fluke 114 Electrical MultimeterThe 114 is ideal for electrical troubleshooting andstraightforward ‘go/no-go’ testing in residential/commercial electrical testing. It has all the basicfunctions plus a special feature to prevent falsereadings caused by ghost voltage.

Features

True RMS readingsCountsBacklightAnalog bargraphAutoVolt: Automatic AC/DC voltage selectionVoltAlert™, Non-contact voltage detectionBuilt-in thermometer for HVAC applicationsLoZ: low input impedance to prevent ghostvoltageMin/Max/Average to record signal fluctuationsResistance, continuityFrequency, Capacitance, Diode testMicroamps to test flame sensorsDisplay holdAuto/manual rangingLow battery indicationCompact case with removable holster

114 115 116 117

±(0.5%+2) ±(0.5%+2) ±(0.5%+2) ±(0.5%+2)

±(1.0%+3) ±(1.0%+3) ±(1.0%+3) ±(1.0%+3)

±(1.0%+3) ±(1.0%+3)

±(1.5%+3) ±(1.5%+3)

±(0.9%+1) ±(0.9%+1) ±(0.9%+1) ±(0.9%+1)

±(1.9%+2) ±(1.9%+2) ±(1.9%+2)

±(0.1%+2) ±(0.1%+2) ±(0.1%+2)

±(1.0%+2)

Functions Maximum Max. resolution

Voltage DC 600V 1mV

Voltage AC 600V 1mV

Current DC 10.00A 1mA

Current AC 10.00A 0.01A

Resistance 40M 0.1

Capacitance 10000µF 1nF

Frequency 50kHz 0.01Hz

Temperature -40°C/+400°C 0.1°C

Specifications

(Check the Fluke web for detailed specifications)

True RMS

Recommended Accessories

Accuracies are best accuracies for each function

Battery type: 9 volt Alkaline, 400 hours typicalSize (HxWxD): 167 mm x 84mm x 46 mm

Weight: 0.55 kg (including batteries)Three Year Warranty

On all inputs

114 115 116 117AC AC AC AC

6000 6000 6000 6000

Fluke 117

Fluke 115

Fluke 114

New Compact design for ergonomic one-handed operation

Fluke 116

Page 20: Fluke 2007

Included AccessoriesTL75 right-angle test leads, two insulatedAC72 alligator clips, spare fuse, 9 Voltbattery and operator’s manual.

Ordering InformationFluke 27 Multimeter

77IV Digital Multimeter

18

Completely sealed to prevent entry ofwater and contaminants

A special extra rugged case with o-ringsprevents water from entering the inputjacks and switches. Use this meter invery harsh, wet or dusty locations. MeetsMIL STD 28800 military specificationsfor vibration, shock, and waterresistance.

• 3200 Digital Display/Counts• 31 Analog Bar Graph/Segments• Fast Auto and Manual Ranging

• Touch Hold®

• Rugged, O-Ring Sealed Case• Separate, Sealed Battery/Fuse Door• Operates from -15°C to +55° and

95% Relative Humidity• Meets Military Shock, Vibration and

Water Resistance Requirements• Min/Max Relative Mode• Audible Continuity/Diode Test• Superior EMI Shielding

Versatile multimeter for field service orbench repair The new 77-IV digital multimeter hasthe features needed to repair mostelectrical and electronic problems. Thismeter is simple to use and has significantimprovements over Fluke’s original 70

Series with more measurement functions,conformance to the latest safetystandards, and a much larger displaythat’s easier to view.

On all inputs

On all inputs

Fluke 27

320.0mV, 3.200V, 32.00V, 320.0V, 1000V ±(0.1% +1)

320.0mV, 3.200V, 32.00V, 320.0V, 1000V ±(0.5% +3)

320.0µA, 3.200 mA, 32.00 mA, 320.0 mA, 10A ±(0.75% +2)

320.0µA, 3.200 mA, 32.00 mA, 320.0 mA, 10A ±(1.5% +2)

320 , 3.200k , 32.00k , 320.0k , 3.200M , 32.00M ±(0.2% +1)

32.00ns ±(2% +10)

Specifications

Range & Resolution: If selected range is 3.200V the resolution is 0.001V in that rangeBattery Life: Typically over 1000 hours (alkaline)Size (HxWxD): 203 mm x 95 mm x 56 mm Weight: 0.75 kg Lifetime Warranty

Function Range & Resolution Best Accuracy

Voltage DC

Voltage AC

Current DC

Current AC

Resistance

Conductance

New

Features

Digital display countsLarge display with backlightMin-Max-Average recording mode with Min/Max AlertHigh contrast digital display with large digitsAnalog bargraph/segmentsAuto and Manual rangingAutomatic Touch Hold®

Audible continuity / diode testErgonomic case with integrated holsterSleep Mode preserves battery lifeEN 61010-1 safety rating

77 IV3200

31

CAT IV 600V / CAT III 1000V

Fluke 77IV

Included AccessoriesTL75 test leads, operator’s manual, 9Vbattery (installed)

Ordering InformationFluke 77IV Multimeter

Function Maximum Max. resolution Accuracy

Voltage DC 1000V 1mV ±(0.3% + 1)

Voltage AC 1000V 1mV ±(2.0% + 2)

Current DC 10A 0.01mA ±(1.5% + 2)

Current AC 10A 0.01mA ±(2.5% + 2)

Resistance 50M 0.1 ±(0.5% + 1)

Capacitance 9999µF 1nF ±(1.2% + 2)

Frequency 99.99kHz 0.01Hz ±(0.1% + 1)

Specifications

Accuracies are best accuracies for each function.

Battery Life: 2000 hours typicalSize (HxWxD): 185 mm x 90 mm x 43 mm

Weight: 0.42 kgLifetime Warranty

27 Sealed Digital Multimeter

Page 21: Fluke 2007

88V Automotive Meter

19

Included AccessoriesH80M Holster with TPAK Meter HangingSolution, TL224 SureGrip Silicone Test LeadSet, TP220 SureGrip Test Probe Set, AC285SureGrip Large Jaw Alligator Clip Set, 80BKIntegrated Temperature Probe, RPM80Inductive Pick-up Probe, C800 Hard Case,User’s Manual + Quick Reference Guide

Ordering InformationFluke 88V/A Automotive Meter Combo Kit

The right meter for auto-electric diagnosis

Perhaps the most important tool you’ll usein troubleshooting auto electrical systems isthe multimeter. Basic multimeters measurevoltage, current and resistance, whileautomotive multimeters like the Fluke 88Vhave features that can check frequency,duty cycle, make diode tests, and measuretemperature, pressure and vacuum.

Features

Continuity for detecting open and shorts

Frequency for “pulsed-DC” and AC tests

Duty cycle to verify operation of feedback carburetors

Diode test for alternator testing

Built-in thermometer; thermocouple probe included

Min/Max/Average recording with Min/Max Alert

Peak capture to record transients as fast as 250 µs

Relative mode to remove test lead resistance from low ohms measurements

Millisecond pulse width measurements for fuel injectors

AutoHOLD® to capture stable readings

Large display with bright, two-level backlight

Magnet hanger to attach meter to the vehicle

RPM80 Inductive Pickup for both conventional and distributorless (DIS) ignitions

Hard Meter Case

Safety rating

88V/A

CAT III 1000V, CAT IV 600V

Fluke 88V

Range Resolution Accuracy1000V 0.1mV 0.1%

1000V (5 kHz) 0.1mV 0.5%10A 0.1µA 0.4%10A 0.1µA 1.2%

50M 0.1 0.4%10mF 0.01nF 1%

200kHz 0.01Hz 0.005%1090ºC 0.1ºC 1%

Voltage DCVoltage ACCurrent DCCurrent ACResistanceCapacitanceFrequencyTemperature

Specifications

Battery Life: 88V – Over 400 hours typical(alkaline)

Size (HxWxD): 88V – 186 mm x 86 mm x 32 mm

Weight: 88V – 0.36 kgLifetime Warranty

On all inputsFluke 88V

Recommended Accessories

Fluke 88V/A

TL82See page 96

TLK-282See page 96

80PK-27 (requires 80AK)See page 92

PV350See page 96

90i-610sSee page 96

Page 22: Fluke 2007

8845A/8846A6.5 Digit Precision Multimeters

20

Fluke 8846A

Precision and versatility for bench orsystems applications The Fluke 8845A and 8846A, 6.5 digitprecision multimeters have the precisionand versatility to handle your mostdemanding measurements on the bench orin a system.

Dual Display offers versatile graphicalcapabilities: The 8845A and 8846Afeatures a unique graphical display that canreveal signal quality issues like drift,intermittent and stability by viewing themeasurement data as a real time TrendPlot™,Histogram or Statistics using the uniqueanalyze mode.Wide Measurement Ranges: Resistance orcurrent has been extended to cover thewidest range possible.

Perform 4-wire measurements easilywith two leads: Patented split terminaljacks for 2x4 Ohms function allows you toperform precise 4-wire measurements withonly two leads instead of four. OptionalKelvin leads accessories are available toenable you to establish a 4-wireconnection even in tight spaces.Systems Capabilities: Both instrumentsinclude an RS-232, IEEE-488 and Ethernetinterface as standard, with popular DMMemulation modes makes systemsintegration a simple task.Software: Transfer data points from yourmeter to your PC with the free copy ofFlukeView Forms Basic. To customize yourforms upgrade with FVF-UG.

True RMS

Recommended Accessories

Included AccessoriesLCI Line Power Cord, TL71 Test Lead Set,Spare Line Power fuse, ProgrammersManual/User Manual on CD-ROM, FVF-BASICFlukeView Forms Software Basic Version.

Ordering InformationFluke 8845A 6.5 Digit Precision

MultimeterFluke 8845A/SU 6.5 Digit Precision

Multimeter (software + cable)Fluke 8846A 6.5 Digit Precision

MultimeterFluke 8846A/SU 6.5 Digit Precision

Multimeter (software + cable)Calibration & Service agreements

DisplayResolutionMeasurement Rate (Rdgs/s)Continuity / Diode TestAnalytical FunctionsMath FunctionsUSB Device PortReal Time ClockInterfacesProgramming Languages/Emulation ModesSafety

Features

8845A 8846ADual VFD Dot Matrix

6.5 Digits1000Yes

Statistics, Histogram, TrendPlot™, Limit CompareNULL, Min/Max, dB/dBm

– USB Memory Drive port– Yes

RS232, IEEE-488.2, EthernetSCPI (IEEE-488.2), Agilent 34401A, Fluke 45

Designed to comply with IEC 61010-12000-1, ANSI / ISA-S82.01-1994, CAN /CSA-C22.2 No.1010.1-92 1000V CATI / 600V CATII

Function*Voltage DCVoltage AC (Freq 300 Hz)Resistance (2x4 Wire)Current DCCurrent AC (Freq. 3Hz-10kHz)Freq/PeriodCapacitanceTemperature RTD

8845A 8846ARange Resolution Accuracy* (%) Range Resolution Accuracy* (%)

1000 V 100 nV 0.0035 1000 V 100 nV 0.0024 750 V 100 nV 0.06 1000 V 100 nV 0.06

100 M 100 µ 0.01 1 G 10 µ 0.0110 A 100 pA 0.05 10 A 100 pA 0.0510 A 1 µA 0.10 10 A 10 nA 0.10

300 kHz 1 µHz 0.01 1 MHz 1 µHz 0.01- - - 1 nF to 0.1 F 1 pF 1- - - -200 to +600º 0.001º 0.06

Specifications

(Check the Fluke web for detailed specification)

TL2X4W-PT 2x4 Wire Ohms Testlead 2mm Probe Tip

884X-512MUSB Memory 512M

FVF-UGFlukeView FormsSoftware Upgrade

Size (HxWxD): 88 mm x 215 mm x 293 mm Weight: 3.6 kg One Year Warranty

* Accuracy =+/- (% of reading)

Use the built-in TrendPlot paperless chart recorder tographically identify the extent of drift and intermittentevents in analog circuits

View results in Histogram mode to reveal stability ornoise problems in analog circuits

Handle even the most demanding measurements withhigh accuracy and 6.5 digit resolution

Fluke 8845A

Page 23: Fluke 2007

Clamp Meters and Electrical Testers

The ergonomic clamp meters feature wide opening jaws for safe, fast non-contact current measurement. The Fluke leakage clampmeter is ideal for non-invasive checks of insulation resistance.The range of electrical testers includes two-pole testers for takingquick measurements in tight spaces, phase rotation indicators to takethe guess work out of checking phase/motor rotation, a multipurposecable locator and handy voltage alerts.

21

Page 24: Fluke 2007

330 Series/902 Clamp Meters

22

H3See page 95

TL223See page 88

L215See page 89

Expanded capabilities for current measurement

Fluke expands its existing line of qualityclamp meters with the Fluke 902. The 902 adds temperature and capacitancemeasurement capabilities to the line, idealfor heating, ventilation and air conditioningsystem inspections. As with the 330 series,the Fluke 902 has the features you need tofit the way you work. The small body andjaws fit perfectly in your hand and intotight places. Meter controls are positioned

so that current measurements can be donewith one hand. A large backlit display (onmost models) is easy to see and a handyDisplay Hold keeps measurements on thedisplay. Measuring starting current for motors,lighting, etc. is easy with the in-rushcurrent function (on most models).

Features

Functions

True-RMS

Display backlight

Auto shut-off

Display Hold

Motor start-up current

Low battery indication

Large jaw

Min/Max

Current AC/DC

Temperature

Specifications

Recommended Accessories

Battery Life: Alkaline, 150 hoursSize (HxWxD):238 mm x 79 mm x 41mm (333, 334, 335 and 902)251 mm x 79 mm x 41 mm (336 and 337)

Jaw Opening: 30 mm (333, 334, 335 and 902)42 mm (336, 337)

Weight: 0.312 kgThree Year Warranty

333 334 335 336 337 902

Functions Range 333 334 335 336 337 902

Current AC 0-400.0A 2% ± 5 counts

0-600.0A 2% ± 5 counts 2% ± 5 counts 2% ± 5 counts 1% ± 5 counts

0-999.9A 2% ± 5 counts

Crest Factor 0-600.0A 2.4 @ 500A 3 @ 500A 2.4 @ 500A

2.0 @ 600A 2.5 @ 600A 2.0 @ 600A

0-999.9A 3 @ 500A

2.5 @ 600A

1.42@ 1000A

Current DC 0-200 µA 1% ± 5 counts

0-600.0A 2% ± 5 counts

0-999.9A 2% ± 5 counts

In-rush Current Integration time 100mS 100mS 100mS 100mS

Voltage AC 0-600.0V 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts

Voltage DC 0-600.0V 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts

Resistance 0-600.0 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts

0-6000 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts

0-9999 1.5% ± 5 counts

Continuity 30 30 30 30 30 30

Frequency 5-400Hz 0.5% ± 5 counts 0.5% ± 5 counts

Temperature -10° to 400°C 1% ± 0.8°C

Capacitance 1µF to 1000µF 1.9% ± 2 counts

Fluke 334 Fluke 333

Fluke 902

Fluke 336 Fluke 335

True RMS

Included AccessoriesC33 Soft case, TL75 test leads, 80BKIntegrated DMM temperature probe (902), 2 AA alkaline batteries, instruction card andsafety information sheet.

Ordering InformationFluke 333 Clamp MeterFluke 334 Clamp MeterFluke 335 True-RMS Clamp MeterFluke 336 True-RMS Clamp MeterFluke 337 True-RMS Clamp MeterFluke 902 True-RMS Clamp Meter

(HVAC)

New

Fluke 337

Page 25: Fluke 2007

320 Series Clamp Meters

23

Included AccessoriesC23 Soft carrying case, TL75 test leads, (2) AA alkaline batteries, coated instructioncard, safety information sheet.

Ordering InformationFluke 321 Clamp Meter Fluke 322 Clamp MeterFluke 117/322 Kit Electricians Combo Kit

H3See page 95

TL223See page 88

L215See page 89

Big features, small packageThe Fluke 321 and 322 are designed toverify the presence of load current, acvoltage and continuity of circuits, switches,fuses and contacts. These small and ruggedclamp meters are ideally suited for currentmeasurements up to 400 A in tight cablecompartments.

Model 322 also offers DC voltagemeasurements and has a higher resolutionfor loads below 40 A.

Features

Compact design

Auto shut-off

Display Hold

Low battery indication

Current AC

Volts DC

Specifications

Recommended Accessories

Battery Life: 100 hours typical (2 AAA carbon zinc)

Size (HxWxD): 190 mm x 63 mm x 35 mmJaw Opening: 25 mm

Weight: 0.23 kgTwo Year Warranty

321 322

321 322 321 322

Functions Range Resolution Range Resolution Best AccuracyCurrent AC 400.0A 0.1A 40.00A 0.01A 1.8% ± 5 counts 1.8% ± 5 counts

400.0A 0.1A (50 - 60Hz) (50 - 60Hz)3.0% ± 5 counts 3.0% ± 5 counts(60Hz – 400Hz) (60Hz – 400Hz)

Voltage AC 0-400.0V 0.1V 0- 400.0V 0.1V 1.2% ± 5 counts 1.2% ± 5 counts400-600V 1V 400 – 600V 1V (50 - 400Hz) (50 - 400Hz)

Voltage DC 0 - 400.0V 0.1V 1% ± 5 counts400 – 600V 1V

Resistance 0 – 400.0 0.1 0 – 400.0 0.1 1% ± 5 counts 1% ± 5 countsContinuity 30 30

Fluke 117/322 KitSee page 13

Combo Kit

Fluke 322

Fluke 321

Page 26: Fluke 2007

24

Included accessoriesSoft carrying pouch and users manual

Ordering informationFluke 360 Leakage Clamp Meter

Leakage current measurements with atough, pocket sized clamp meter

The Fluke 360 is ideal for non-invasivechecks of insulation resistance. The unique jaw design eliminates theinfluence of adjacent current conductors.The ergonomic design of the Fluke 360ensures easy measuring. The measuringclamp fits into tight spaces and the widedisplay angle clearly shows themeasurement result. The data hold buttonkeeps the measured value on the displayafter removing the clamp for the measuredconductor.

The light Fluke 360 offers the widest rangeof current measurement for maintenanceprofessionals and contractors.

Features• Measurement of leakage protectives

conductor and touch current with aresolution of 1µA

• Advanced shielding to ensure accurateresults when measuring near otherconductors

• Automatic ranging within the manuallyselected mA or A range

• Easily viewed measurements on digitaland bargraph display and HOLD whenmeasuring in hard to see locations

• Broad range of measurements currents upto 60 A for all installation needs

• Easy carrying, pocket sized clamp withwide 40 mm jaw size

• Display-Hold for convenience in use• Auto power off with audible warning

buzzer• Conformance to IEC61010 and EMC

standard• Meets all the applications and

performance classes in safety standardVDE0404-4 and the new VDE0702

Functions Range Resolution Accuracy

Current AC 3mA 0.001mA 1% ± 5 counts30mA 0.01mA

30A 0.01A 1% ± 5 counts (0~50A)60A 0.1A 5% ± 5 counts (50~60A)

Frequency 50 and 60Hz

Battery type: 3 Volt Lithium, 90 hours typicalSize (HxWxD): 176 mm x 70mm x 25 mmWeight: 0.2kgOne Year warranty

Specifications(Check the Fluke web for detailed specifications)

leakagecurrent 0.5mA

display: 1.7mA

ground leakage current1.2mA (e.g. viamotor shaft)

New

360 Leakage Clamp Meter

Fluke 360

Page 27: Fluke 2007

T100 Series/T50Voltage and Continuity Testers

25

Included AccessoriesTwo 1.5V batteries and instruction sheet

Ordering InformationFluke T50 Voltage/Continuity TesterFluke T100 Voltage/Continuity TesterFluke T120 Voltage/Continuity Tester Fluke T140 Voltage/Continuity Tester

UK versions are compliant with GS38

Not available in all countries

The fast and easy solution to voltage, continuity and phase rotation testingFluke T50Offers a low cost solution to voltage-continuity measurement. It contains anacoustic and optic continuity test and featuresa single pole test for phase detection.

Fluke T100 SeriesThe fast and easy solution to voltage,continuity and resistance measurements.Ideal for site conditions, the 3 models of theT100 Series 2-pole testers have a ruggedconstruction and ergonomically formed

housing for perfect handling. All modelsoffer a patented three-phase rotationdetection system providing quick phaserotation indication.Moreover they have a special electrical torchfunction for working in low light levelenvironments and have an ingress protectionrating of IP65. The T100 Series are compliantwith EN 61010-1 and EN61243-3requirements.

Features

T50 T100 T120 T140

12 – 690V 12 – 690V 12 – 690V 12 – 690V

0 – 200kΩ 0 – 400kΩ 0 – 400kΩ 0 – 400kΩ

0 – 65Hz 0 – 400Hz 0 – 400Hz 0 – 400Hz

- 100 to 690V 100 to 690V 100 to 690V

- - - Up to 1999Ω

< 0.1s < 0.1s < 0.1s < 0.1s

Voltage AC/DC

Continuity

Frequency

Phase Rotation

Resistance measurement

Response time

Specifications

Size T50 (HxWxD): 210 mm x 40 mm x 22 mmSize T100/T120/T140 (HxWxD):240 mm x 56 mm x 24 mmCase: T100/T120/T140: IP65

(water-jet and dust tight protection)T50: IP54

Weight T50: 130 gWeight T100/T120/T140: 180 gTwo year warranty

Fluke T100

Fluke T50

T50 T100 T120 T140

LCD LCD

10 LED’s 12 LED’s 12 LED’s 12 LED’s

Display

LED Bargraph

Backlight

Resistance measurement

Voltage test

Optical and acoustical continuity test

Rotary field indication

Single pole test for phase detection

Indication of polarity

Electrical torch function

Probe tip protection

The voltage display also functions when usingdischarged - or no batteries

Fluke T120

Fluke T140

C23 (T50)See page 94

C33 (T100 Series) See page 94

Recommended Accessories

Page 28: Fluke 2007

Operating range: 200 – 1000V ACBatteries: Two AAA AlkalineSize (H): 148 mm Two Year Warranty

Fluke 1AC II VoltAlert™5-pack• Buy 4 get 1 FREE

26

Fluke 1AC II VoltAlert™The Fluke VoltAlert AC voltage detector isvery easy to use – just touch the tip to aterminal strip, outlet or cord. When the tipglows red and the unit beeps, you knowthere is voltage on the line.• It continually tests its battery and its circuit

integrity with a periodic double flashvisual indication.

• Highest safety rating: CAT IV 1000V• Detects voltage without metallic contact

LVD1 Volt Light LVD2 Volt LightDual sensitivity voltage detector• Detects voltage from 40V to 300V AC• Blue light means you’re close• Red light means you’re at the source• Comes with a versatile clip to secure light

to pocket, hat or even panel door

Combines bright light and voltage detectionin one pen style design• Dual sensitivity • Detects voltage from 90V to 600V AC• Blue light means you’re close• Red light means you’re at the source• Rated to CAT IV 600V

H5See page 95

ACC-T5-KitSee page 89

AC285See page 89

T5 Electrical Testers 1AC II Volt Alert

LVD1/LVD2 Volt Light

The fast and easy solution to basic electrical testingFluke T5-600 and T5-1000 Voltage,Continuity and Current TestersThe Fluke T5 testers let you check voltage,continuity and current with one compacttool. Select volts, ohms or current and theinstrument does the rest. Model T5-600measures 600 volts AC/DC, model T5-1000is designed for 1000 volts. OpenJaw™current technology lets you check currentup to 100 A, without breaking the circuit.The optional H5 holster keeps the test probesand leads ready to test and lets you clipthe T5 onto your belt.

Recommended Accessories T5T5-H5-1AC Kit

Battery life: 400 hoursSize (HxWxD): 203 mm x 51 mm x 30.5 mm

Weight: 0.38 kgTwo year warranty

Fluke T5-1000 Fluke T5-600

Features and Specifications

Display CountAutomatic SelectionContinuity and BleeperSleep ModeAC VoltageDC VoltageAC CurrentResistanceSafety range

T5-600 T5-10001000 1000

600V 1000V600V 1000V100A 100A

1000 1000600V CAT III 1000V CAT III

Included AccessoriesT5-600 and T5-1000:TP4 4 mm detachable probes (detachableGS38 probes for the UK) and instruction sheet

Ordering InformationFluke T5-600 Electrical TesterFluke T5-1000 Electrical TesterFluke 1AC II VoltAlertFluke 1AC II 5PK VoltAlert (5-pack)LVD1 Volt LightLVD2 Volt LightT5-H5-1AC Kit

• T5-1000 Electrical Tester

• H5 Holster• 1AC VoltAlert

for free

LVD2

LVD1 Fluke 1AC II

Page 29: Fluke 2007

Fluke 9040

27

9040/9062Phase Rotation Indicators

Included AccessoriesFluke 9040: Alligator clips - black (3)Flexible test probes - black (3)Fluke 9062: Alligator clips - black (3)Flexible test probes - black (3)Test leads - black (3)

Ordering InformationFluke 9040 Phase Rotation IndicatorFluke 9062 Motor and Phase Rotation

Indicator

Not available in all countries

Take the guess work out of phase/motorrotation measurementsFluke 9040The Fluke 9040 is effective for measuringphase rotation in all areas where three-phase supplies are used to feed motors,drives and electrical systems. The Fluke9040 is a rotary field indicator and canprovide clear indication of the 3 phase viaan LCD display and the phase rotationdirection to determine correct connections.It allows rapid determination of phasesequence and has a voltage (up to 700V)and frequency range suitable for commercialand industrial applications. Test probessupplied with the instrument have a variableclamping range for safe contact, especiallyin industrial sockets.

Fluke 9062The unique Fluke 9062 provides rotaryfield and motor rotation indication with thebenefits of contact-less detection.Purpose made for commercial and industrialenvironments, the Fluke 9062 providesrapid indication of 3 phase rotation usingtest leads supplied or can be used todetermine motor rotation on synchronousand asynchronous 3 phase motors. Thecontact-less detection is ideal for use onmotors where the shaft is not visible.Test probes supplied with the instrumenthave a variable clamping range for safecontact, especially in industrial sockets.

9040 9062

40-700V Up to 440V

- 120-440V AC

15-400Hz 2-400Hz

Continuous Continuous

Voltage range

Phase Display

Frequency range

Operating time

Specifications

Size (HxWxD) Fluke 9040:124 mm x 61 mm x 27 mmSize (HxWxD) Fluke 9062:124 mm x 61 mm x 27 mm

Power supply 9040: from unit under testPower supply 9062: 1 x 9VWeight 9040: 0.20 kgWeight 9062: 0.15 kgTwo Year Warranty

Features

9040 9062

Via LCD Via LED

3 phase indication

Indication of phase rotation

Indication of motor rotation direction

Contact free determination of the rotation direction of running motors

Clear LCD display

No battery required

TLK290 See page 89

TLK291 See page 89

C25See page 94

Recommended Accessories

Fluke 9062 applications

Determine the presence ofphase sequence of multiphase

electrical supplies.

Determine the rotation ofrunning motors simply byplacing the instrument on

the motor casing.

Check the correct rotation ofmotors prior to connection.

Fluke 9062

9062:

9040:

Page 30: Fluke 2007

28

2042 Cable Locator

Included AccessoriesTL27 Heavy Duty Test Lead Set (2)TP74 Lantern Tip Test Probe SetAC285 Alligator Clip SetSoft carrying caseHard case

Ordering InformationFluke 2042 Cable Locator

(transmitter + receiver)Fluke 2042T Cable Locator Transmitter

Not available in all countries

The Fluke 2042 is a professional generalpurpose cable locator. It is ideal for tracingcables in walls and underground, locatingfuses/breakers on final circuits and locatinginterruptions and short-circuits in cablesand electrical floor heating systems.It can also be used for tracing metallic waterand heating pipes. The unit is supplied as acomplete kit comprising of a transmitterand receiver in a purpose-made carry case.The receiver also incorporates a torchfunction for working in dimly lit locations.

• For all applications (live or dead cables)without additional instruments

• Set includes a transmitter and a receiver• Proven digitally coded sender signal

guarantees clear signal identification • Transmitter with LCD-display for

transmitting level, transmitting code andexternal voltage

• Receiver with a backlight LCD-display forlevel of receiving signal, code of receivingsignal and live voltage indication

• Automatic or manual adjustment ofreceiving signal sensitivity

• Switchable acoustic receiving signal • Auto-Power-Off• Additional torch lamp function for working

in dark environments• Additional transmitters are available for

extension or to distinguish betweenseveral signals.

Transmitter Receiver

12V, 50V, 120V, 230V, 400V

0..60Hz

125 kHz

Up to 400V AC/DC

0…2.5m wall/underground cables

0…0.4m

Voltage Measurement Range

Frequency Range

Output signal

Voltage

Tracing depth cable location

Main voltage detection

Specifications

Batteries Transmitter: 6 pc Batteries 1.5V Batteries Receiver: 1 pc Battery 9VSize (HxWxD) Transmitter:190 mm x 85 mm x 50 mmSize (HxWxD) Receiver:250 mm x 65 mm x 45mmWeight Locator: 0.45 kgWeight Receiver: 0.36 kgTwo Year Warranty

Fluke 2042

Receiver

Fluke 2042T

Recommended Accessories

Fluke 2042 applications

Location of fuses/breakers andassignment to circuits

Tracing of underground cables(max. depth 2.5 m)

Precise location of cableinterruptions with additional

transmitter

The multipurpose solution to cable location

Transmitter

Page 31: Fluke 2007

Insulation Testers and Earth Ground Testers

With a 5000 V MegOhmMeter for industrial-strength insulation testingand a range of compact hand-held instruments, we offer a solution for every troubleshooting and preventive maintenance application. Two of the digital hand-held insulation testers also include full-featured multimeters.The Fluke Earth Ground Testers can perform all four types of earthground measurement, including stakeless testing with earth groundloop resistances using only clamps.

29

Page 32: Fluke 2007

Insulation Tester Selection Guide

30

1577 1587 1587T 1503 1507 1550B

500V, 1000V 50V, 100V, 250V, 50V, 100V 500V, 1000V 50V, 100V, 250V, 250V, 500V, 500V, 1000V 500V, 1000V 1000V, 2500V,

5000V0.1M - 600M 0.01 M - 2G 0.01M - 100M 0.1M - 2G 0.01M - 10G 200K - 1T

1000 1000 1000 1000 1000

(99 locations)

Digital LCD Digital LCD Digital LCD Digital LCD Digital LCD Digital LCD/Analog Bar Graph

(200mA) (200mA)

(Fluke View®

Forms Basic)3 3 3 1 1 2

4 AA (NEDA 15A 4 AA (NEDA 15A 4 AA (NEDA 15A 4 AA (NEDA 15A 4 AA (NEDA 15A Rechargableor IEC LR6) or IEC LR6) or IEC LR6) or IEC LR6) or IEC LR6)

Installation Test FunctionalityTest Voltages

Insulation Resistance Test Range

Polarization Index/Dielectric Absorption Ratio

Auto Discharge

Time Ramp test (Breakdown)

Pass/Fail Comparison

Estimated Number ofInsulation resistance Tests

Voltage > 30V Warning

Memory

Remote Test Probe

Lo Ohms

Display

Continuity

Multimeter FunctionalityAC/DC Volts

Current

Resistance

Temperature (contact)

Lo-Pass Filter

Capacitance

Diode Test

Frequency

MIN/MAX

OtherHold/Lock

Backlight

Software

Warranty (in years)

Battery

Page 33: Fluke 2007

1550B MegOhmMeter

31

Included AccessoriesTest leads, 5000 V-rated probes, Alligatorclips, Interface cableQuicklink 1550B PC software, soft carryingcase with water-proof bottom, instructionmanual

Ordering InformationFluke 1550B MegOhmMeter

Digital insulation testing up to 5000 VoltsThe Fluke 1550B is a digital insulation testercapable of testing switchgear, motors,generators and cables at up to 5000 V DC.It can be used for a wide range of tests:from simple spot checks to timed tests andbreakdown tests. Measurement storage andPC interface software make it ideal forpreventive maintenance.

• Test voltages of 250 V, 500 V, 1000 V,2500 V, 5000 V

• Capable of testing in 50 V incrementsbetween 250 V and 1000 V and 100 Vincrements between 1000 V and 5000 V

• Measures 0 to 1 Tera-Ohm • Warning voltage function alerts the user

that line voltage is present and gives thevoltage reading up to 600V AC or DC

• Guard system eliminates the effect ofsurface leakage current on high-resistancemeasurements

• Large digital/analog LCD shows detailedmeasurement data

• Cable or insulation capacitance• Leakage current• Ramp function (0-5000 V DC) for

breakdown testing• Timer 1 to 99 minutes• Polarization index and dielectric absorption

calculated automatically• 99 memory locations store all

measurements parameters• Includes Quicklink 1550B Software and

Optical Interface cable

Specifications

Operating Temperature: -20°C to 50°CStorage Temperature: -20°C to 65°CRelative humidity: 80% at 31°C, 50% at 50°CDust/water resistance: IP40Operating Altitude: 0 to 2,000 mtrs.

Batteries: 12 volt, lead-acid, rechargeableSize (HxWxD): 170 mm x 242 mm x 330 mmWeight: 4 kg (with battery)Two Year Warranty

Test Voltage (DC) Range Accuracy (+/- reading)

250V 200k to 5G 5%5G to 50G 20%

500V 200k to 10G 5%10G to 100G 20%

1000V 200k to 20G 5%20G to 200G 20%

2500V 200k to 50G 5%50G to 500G 20%

5000V 200k to 100G 5%100G to 1T 20%

Short circuit current greater than 1 mA and less than 2mABar graph range 0 to 1TInsulation test voltage accuracy 0% to + 10% at 1mA load currentInduced AC mains current rejection 2 mA maximumCharging rate for capacitive load 5 seconds per µF

Leakage current 1nA to 2mA ± (5% + 2nA)Capacitance measurements 0.01µF to 15.00µF

± (15% rdg + 0.03µF)Live circuit indicator 30V to 600V ± (5% + 2V)

AC/DC, 50/60HzTimer increments; 1 to 99 minutes; settable in 1 minuteindicated to within 1 secondRamp 0% to 100% of selected test voltage,

or until breakdown.

Fluke 1550B

FVF-SC2See page 97

Recommended Accessories

Page 34: Fluke 2007

Included AccessoriesC101 Rugged, utility hard caseTL224 SureGrip Silicone Test Lead SetAC285 SureGrip Alligator Clip Set80BK Integrated DMM Temperature Probe(Type K)TP165X Remote Test Probe

Ordering InformationFluke 1577 Insulation MultimeterFluke 1587 Insulation MultimeterFluke 1587T Insulation Multimeter

(for Telecom)

1577/1587Insulation Multimeters

32

Two powerful tools in oneThe Fluke 1587 and 1577 InsulationMultimeters combine a digital insulationtester with a full-featured True RMS digitalmultimeter in a single compact, handheldunit, which provides maximum versatilityfor both troubleshooting and preventivemaintenance.

Whether you work on motors, generators,cables, or switch-gear, the Fluke 1587/1577Insulation Multimeters are ideally suited tohelp you with your tasks.

The Fluke 1587T is specially designed forthe telecom environment.

1577 1587 1587T0.1M to 600M 0.01M to 2G 0.01M to 100M500V, 1000V 50V, 100V, 250V, 50V, 100V

500V, 1000V+ 20%, - 0% + 20%, - 0% + 20%, - 0%1 mA nominal 1 mA nominal 1 mA nominalDischarge time < 0.5s Discharge time < 0.5s Discharge time < 0.5sfor C = 1µF or less for C =1µF or less for C =1µF or lessUp to 1µF load Up to 1µF load Up to 1µF load

Measurement rangeTest voltages

Test voltage accuracyInsulation test currentAuto discharge

Maximum capacitive load

Insulation Specifications

C25See page 94

i400See page 90

TPAKSee page 97

L215See page 89

TL238See page 88

Recommended Accessories

Features

Multimeter FeaturesTrue RMS Voltage and Current for accurate measurementsDigital display countsAutorange and manual range for easy testing.Selectable filter for accurate voltage and frequency measurements on motordrivesMin Max Recording, Diode test, temperature, capacitance & frequencymeasurement for maximum flexibility.

Insulation featuresUser selectable test voltages for many applicationsAdditional test voltages 50V, 100V, 250V Special remote control probe for easy and safe measurementsAuto-discharge of capacitive voltage for added user protectionLive circuit detection prevents insulation test if voltage > 30V is detected foradded user protection

General featuresAuto Power off to save batteriesLarge display with backlightInput Alert to warn for incorrect connectionsContinuity

1577 1587 1587T

6000 6000 6000

Functions Maximum Max. resolutionVoltage DC 1000V 1 mVVoltage AC 1000V 0.1mVCurrent DC 400mA 0.01mACurrent AC 400mA 0.01mAResistance 50.0M 0.1Capacitance 9999µF 1 nFFrequency 99.99kHz 0.01 HzTemperature -40°C to +537°C 0.1°C

1577 1587/1587T± (0.2% + 2) ± (0.09% + 2)± (2% + 3) ± (2% + 3)± (1.0% + 2) ± (0.2% + 2)± (2% + 2) ± (1.5% + 2)± (1.2% + 2) ± (0.9% + 2)

- ± (1.2% + 2)- ± (0.1% + 1)- ± (1% + 10)

Multimeter Specifications

Battery life: Meter: 1000 hrs, Insulation Test: >1000 tests

Size (HxWxD):203 mm x 100 mm x 50 mm

Weight: 0.55 kgThree Year Warranty

Fluke 1577

Fluke 1587Fluke 1587T

Page 35: Fluke 2007

1587 Combo Kits

33

Ordering InformationFluke 1587/ET Advanced Electrical

Troubleshooting KitFluke 1587/MDT Advanced Motor & Drive

Troubleshooting Kit

Fluke 1587/ET Advanced ElectricalTroubleshooting Kit

This kit contains:• Fluke 1587 Insulation Multimeter• Fluke 62 Mini Infrared Thermometer• i400 Current Clamp

Perform insulation tests with the Fluke 1587plus a wide-range of DMM tasks withconfidence and ease. Use the i400 with yourFluke 1587 to accurately measure AC currentwithout breaking the circuit. Check for hotspots and measure temperature with the Fluke62 Mini non-contact thermometer.

Fluke 1587/MDT Advanced Motor & Drive Troubleshooting Kit

This kit contains:• Fluke 1587 Insulation Multimeter• Fluke 9040 Phase Rotation Indicator• i400 Current Clamp

Perform insulation tests with the Fluke 1587plus a wide-range of DMM tasks withconfidence and ease. Use the i400 with yourFluke 1587 to accurately measure AC currentwithout breaking the circuit. Check the phase-rotation of three-phase motors easilyand safely with the Fluke 9040.

Save10%

Save10%

Buy a Combo Kit and saveThe products in these kits have beenspecifically selected for both troubleshootingand preventative maintenance applications.Establishing preventative maintenanceprograms is becoming critical for main-taining the uptime of electrical equipment,and can significantly reduce both planned

and unplanned downtime. Unplanneddowntime costs are difficult to calculate,but often these cost are significant. Forsome industries, they may even represent1% to 3% of revenue (potentially 30% to40% of profits) annually.

Page 36: Fluke 2007

1503/1507 Insulation Testers

34

Included AccessoriesTP165x Remote Test ProbeTL224 SureGrip Silicone Test Lead SetTP74 Lantern Tip Test Probe Set

Alligator clips

Ordering InformationFluke 1503 Insulation TesterFluke 1507 Insulation Tester

Truly portable insulation resistance testersWhen you need a low cost solution togeneral purpose insulation testing look nofurther than the new Fluke insulation testerrange. The Fluke 1507 and 1503 InsulationTesters are compact, rugged, reliable andeasy to use.

The multiple test voltages on both modelsmake them ideal for many troubleshooting,commissioning and preventive maintenanceapplications. Additional features like theremote probe save both time and moneywhen performing tests.

1503 15070.1 M to 2 G 0.01 M to 10 G500 V, 1000 V 50 V, 100 V, 250 V, 500 V, 1000 V+ 20 %, - 0 % + 20 %, - 0 %1mA nominal 1mA nominal600 V (0.1 V resolution) 600 V (0.1 V resolution)0.01 to 20 k 0.01 to 20 kDischarge time < 0.5 second Discharge time < 0.5 secondfor C = 1 µF or less for C = 1 µF or lessUp to 1 µF Up to 1 µF> 4 V , < 8 V > 4 V , < 8 V> 200 mA > 200 mA

Insulation specificationsInsulation test rangeTest voltagesTest voltage accuracyInsulation test currentAC/DC Voltage measurementResistance measurement rangeAuto discharge

Maximum capacitive loadOpen circuit test voltageShort circuit current

Specifications

Battery life: Insulation Test: > 1000 testsSize (HxWxD):203 mm x 100 mm x 50 mm

Weight: 0.55 kgOne Year Warranty

C101See page 95

TPAKSee page 97

TLK 225See page 88

AC285See page 89

L210See page 98

Recommended Accessories

Features

User selectable test voltages for many applicationsAdditional test voltages 50V, 100V, 250VSpecial remote control probe for easy and safe measurementsAuto-discharge of capacitive voltage for added user protectionLive circuit detection prevents insulation test if voltage > 30 V is detected for added user protectionSave both time and money with Automatic calculation of Polarization Index and Dielectric Absorption RatioAuto Power off to save batteriesLarge display with backlightContinuity function (200 mA)Compare function (pass/fail) for fast repetitive tests

1503 1507

Fluke 1503

Fluke 1507

Page 37: Fluke 2007

1620 SeriesEarth Ground Testers GEO

35

Included accessoriesFluke 1623: Protective holster with carry belt,2 test leads, 2 alligator clips, 1 shortingjumper, users manualFluke 1623 Kit: same as above plus stake/reelSet 4 pole and selective/stakeless clamp setFluke 1625: Protective holster, 2 test leads, 2 alligator clips, carrying strap, users manualFluke 1625 Kit: same as above plus stake/reelset 4 pole and selective/stakeless clamp set

Ordering informationFluke 1623 Basic GEO Earth Ground

TesterFluke 1623 Kit Basic GEO Earth Ground

Tester KitFluke 1625 Advanced GEO Earth

Ground TesterFluke 1625 Kit Advanced GEO Earth

Ground Tester Kit

Advanced technology for all your earthground testing applicationsThe new Fluke 1620 Series Earth GroundTesters not only measure ground resistanceusing the classic ‘fall of potential test’ butalso enable time saving testing using the‘selective’ and ‘stakeless’ methods.‘Selective’ testing does not require theelectrode under test to be disconnectedduring the measurement, thus increasingsafety. The simple ‘stakeless’ methodquickly checks ground connections usingtwo current transformers (probes) clampedaround the ground conductor under test.Offering ‘one-button’ simplicity, the 1623 is

an all-in-one earth ground tester, while the1625 has extra versatility for moredemanding applications.

Earth ground resistance and soilresistivity should be measured when:• Designing earth ground systems• Installing new ground system and

electrical equipment• Periodically testing ground and lightning

protection systems• Installing large electrical equipment such as

transformers, switchgears, machines, etc.

Features

Fluke 1625

Fluke 1623

1623 1625

Resistance ranges 0 to 20 k 0 to 300 k

Operating error ± 5% ± 5%

Test voltage 48V 20/48V

Short circuit current > 50mA 250mA

Battery type: 6 x AA alkaline cellsSize (HxWxD): 110 mm x 180 mm x 240 mmWeight – 1623 Geo: 1.1 kg (including batteries)

1625 Geo: 1.5 kg (including batteries)Two Year Warranty

Specifications(Check the Fluke web for detailed specifications)

EI-1623Selective/stakelessclamp set for 1623

EI-1625Selective/stakelessclamp set for 1625

ES-162P3Stake/reel set for 3pole measurements

ES-162P4Stake/reel set for 4pole measurements

EI-162BN320mm Split core

transformer forselective

measurements onhigh voltage pylons

Recommended Accessories

1623 1625

One-button measurement concept

3- and 4-pole earth ground measurement

4-Pole soil resistivity testing

2-Pole resistance measurement AC

2-and 4-pole resistance measurement DC

Selective testing, no disconnection of ground conductor (1 clamp)

Stakeless testing, quick ground loop testing (2 clamps)

Measuring frequency 128 Hz

Earth impedance measurement at 55 Hz

Automatic frequency control (AFC) (94 – 128 Hz)

Measuring voltage switchable 20/48V

Programmable limits, settings

Continuity with buzzer

Dust/water resistance IP56 IP56

Safety rating CAT II 300 V CAT II 300 V

Fluke 1625 kit

Page 38: Fluke 2007

36

Fluke 1630

1630 Earth GroundClamp Meter

Included AccessoriesRugged carrying case with belt, Resistancetest loop, 9 V battery, Operating instructions.

Ordering InformationFluke 1630 Earth Ground Clamp Meter

Fast and easy earth ground loop testingThe Fluke 1630 earth ground clamp metersimplifies ground loop testing and enablesnon-intrusive leakage current measurement.The ground loop testing is also known as“stakeless” earth ground testing. To carryout the measurement there is no need forplacing earth stakes and disconnecting theearth system from the electrical installation.The Fluke 1630 combines the two currentclamps needed to perform the stakelessground loop test in one compact and easyto use instrument. • Ground loop resistance testing without

any disconnection or additional earthstakes

• Earth ground leakage currentmeasurement for system troubleshooting

• True RMS AC current measurement rangeup to 30 A

• Rapid evaluation of continuity withoutdisconnection and audible HI/LO alarm

• Display-HOLD function to freezemeasurements

• Recording function for automatic storageof measured values, which can berecalled later on the LCD display

• Automatic self calibration ensures correctmeasurement every time

The Fluke 1630 is ideally suited for thefollowing applications:• Ground loop checks on any earthing

system• Continuity tests on earth bonding circuits

and connections• Inspection of lightning protection systems• Leakage current measurement for

troubleshooting on earth ground systems

Range Accuracy

Resistance 0.025 to 1500 0.002

Continuity buzzer < app. 40

Leakage current 0.2 to 1000 mA 0.001 mA

Current 0.2 to 30 A 0.01 A

Weight: 0,64 kg Conductor Size: 23 mm approx.Size (HxWxD): 257 mm x 100 mm x 47 mmBattery type: 9 V IEC 6 LR 61Two Year Warranty

Specifications

(Check the Fluke web for detailed specifications)

New

Page 39: Fluke 2007

Installation Testers/Portable Appliance Testers

Our multifunction testers have redefined the standards for ease-of-use.Designed for ensuring fixed wiring is installed according to IEC 60364,they perform all tests required to verify safety. Our Portable ApplianceTesters verify the safety and operation of portable appliances, and aredesigned for ‘one-touch’ operation and a fast throughput.

37

Page 40: Fluke 2007

38

MTC1363 (UK)Mains Test Cord

MTC77 (Europe)Mains Test Cord

ES165X (1653)Earth Spike Test Kit

FVF-SC2 (1653)See page 97

1650 Series MultifunctionInstallation Testers

The perfect installation testing solutionThe Fluke 1650 Series testers verify thesafety of electrical installations in domestic,commercial and industrial applications. Theycan ensure that fixed wiring is safe andcorrectly installed to meet the requirementsof IEC 60364, HD 384 and all relevant local standards. The unique ergonomic design, low weightand padded neck-strap to free your hands,make operating a Fluke 1650 multifuctiontester a pleasure. With easy-to-operatecontrols and large display with exceptionallywide viewing angle, it’s also comfortableand safe to use.

• Easy: simply turn the knob, press thebutton and see the results

• Efficient: measure loop impedancewithout tripping RCDs, eliminating theneed to bypass them

• Rugged: withstands a one-meter dropfor demanding field use

• Safe: slim probe with test button keepsyour eyes on the panel while probinghard to reach points

• Comfortable: compact and lightweight(less than 1.2 kg) for all day testing

• Compliant: meets all relevant standardsincluding EN 61557 and VDE 0413

Rotary knob labeling is available in sixversions. Select from English, French,German, Italian, Spanish or a user-friendlySymbols version.

Features

Measurement functions

Voltage & Frequency

Wiring polarity

Insulation Resistance

Continuity

Loop & Line Resistance

PFC/PSC (short-circuit current)

RCD tripping time

RCD tripping current level

Automatic RCD test sequence

Test of pulse sensitive RCD’s

Earth Resistance

Phase Sequence Indicator

Other features

Self-test

EN 61557*/VDE 0413 compliant

Illuminated Display

Line voltage indicator

Battery indicator and battery test function

Memory, Interface

Memory (500 measurements)

Computer interface

Time stamp (with FlukeView® Forms)

Software

Recommended Accessories

Fluke xx

1651 1652 1653

500, 1000 V 250, 500, 50, 100, 250,1000 V 500, 1000 V

ramp test ramp test

option

Included AccessoriesTP165X Remote Control Probe (1652 and1653 only) TL165X STD Standard Test Lead SetC1600 Hard Carrying CaseMains Test CordPadded Carrying StrapQuick Reference Guide6 AA Cell batteries

Ordering InformationFluke 1651 Multifunction Installation TesterFluke 1652 Multifunction Installation TesterFluke 1653 Multifunction Installation Tester

Check the Fluke website for the varioussoftware modules

BS7671 16th Edition IEE WiringRegulations IEC 60364.6.61, HD 384

* 1651: sections 1, 2, 3, 4, 6, 101652: sections 1, 2, 3, 4, 6, 101653: sections 1, 2, 3, 4, 5, 6, 7, 10

Fluke 1653

Fluke 1652

Fluke 1651

Page 41: Fluke 2007

1650 Series MultifunctionInstallation Testers

The perfect installation testing solution

39

Specifications

Battery type: Alkaline supplied. usable with 1.2 V NiCD or NiMH rechargeable batteriesSize (HxWxD): 100 mm x 250 mm x 125 mm

Weight: 1.17 kgThree Years Warranty

Slim probe designThanks to its slim probe with integral test button,you can safely make one-handed measurementson hard to reach points, while keeping your eyeson the panel.

Professional reportsUp to 500 test results can be stored in the 1653installation tester. The data stored for eachmeasurement consists of the test function, userselectable test conditions and unique references. Model 1653 has an IR port and adaptor to enablethe results to be uploaded to a computer forpreparing professional reports.

Complete kitAll 1650 models are equipped with detachableleads that can be replaced in case of damage orloss. A durable hard case will protect yourinstrument in tough field conditions.

AC Voltage MeasurementRange Resolution Accuracy Input Impedance Overload Protection

50 Hz – 60 Hz500 V 0.1 V 0.8% + 3 3.3 M 660 Vrms

Continuity TestingRange (autoranging) Resolution Test Current Open Circuit Voltage Accuracy

20 0.01 200 0.1 > 200 mA > 4 V ± (1.5%+3 digits)

2000 1Insulation Resistance Measurement

Model Test Insulation Resolution Test Current AccuracyVoltage Resistance Range

1653 50 V 10 k to 50 M 0.01 M 1 mA @ 50 k ± (3%+ 3 digits)

1653 100 V 100 k to 20 M 0.01 M 1 mA @ 100 k ± (3%+ 3 digits)20 M to 100 M 0.1 M ± (3%+ 3 digits)

1653, 1652 250 V 100 k to 20 M 0.01 M 1 mA @ 250 k ± (1.5%+ 3 digits)20 M to 200 M 0.1 M

1653, 1652, 1651 500 V 100 k to 20 M 0.01 M 1 mA @ 500 k ± (1.5%+ 3 digits)20 M to 200 M 0.1 M + 10%

200 M to 500 M 1 M

1653, 1652, 1651 1000 V 100 k to 200 M 0.1 M 1 mA @ 1 M ± (1.5%+ 3 digits)200 M to 1000 M 1 M + 10%

Loop Impedance MeasurementRange Resolution Accuracy20 0.01

200 0.1 ± (3% + 10 digits)2000 1

PFC. PSC Test Range 0 to 50 kAResolution and Units IK < 1000 A 1 A

IK 1000 A 0.1 kAAccuracy Determined by accuracy of loop resistance and mains voltage measurementsRCD Testing

RCD Type 1651 1652 16531AC 2G

AC 3S 4A G

A S 1AC – responds to AC 2G – General, no delay 3S – Time delay 4A - Responds to pulsed signalTripping Time Test (∆T)

Current Settings Multiplier Test Current Accuracy Trip Time Accuracy10, 30, 100, 300, 500, 1000 mA x 1/2 ± 0% - 10% ± (1% Reading + 1 digit)10, 30, 100, 300, 500, 1000 mA x 1 ± 10% - 0% ± (1% Reading + 1 digit)

10. 30 mA x 5 ± 10% ± (1% Reading + 1 digit)Tripping Current (Ramp) Test – Fluke 1653 and 1652 only

Current Range Step size Dwell time Trip Current Type G Type S Measurement Accuracy

50% to 110% of 10% of I N 300 ms/step 500 ms/step ± 5%RCD’s rated current

Earth Resistance Test (RE) – Fluke 1653 onlyRange Resolution Accuracy200 0.1 ± (2%+ 5 digits)

2000 1 ± (3.5%+ 10 digits)

Page 42: Fluke 2007

6000 Series PAT Testers

40

Included AccessoriesTest lead, Test probe, Crocodile clip, Mains cord

Ordering InformationFluke 6200 PAT TesterFluke 6500 PAT Tester

Not available in all countries

Also available with European mains socket.

Versatile PAT testing at your fingertipsThe Fluke 6200 and 6500 PAT testers verify the electrical safety and operation ofportable appliances in accordance withrelevant guidelines and regulations. Withpowerful auto test capabilities and simplifiedcontrols they increase the number of testsyou can perform per day withoutcompromizing results.

A choice of automatic and manualPAT testersBoth models perform all the tests requiredfor class I and class II appliances. For manualtesting and low volume applications, choosethe cost-effective 6200 PAT model. If youneed a more powerful instrument to test largenumbers of appliances, the 6500 is theright choice.

Fluke simplifies portable appliance testing • Compact and lightweight…

Efficient to work with and easy to carryaround– and has extra space in the hardcase for accessories.

• One touch simplicity…Pre-set and user-definable test routinesare initiated from a single button – tospeed up test procedures and save youtime on site.

• A better way of working…Rapid data entry via a QWERTY keyboard(or optional Fluke barcode scanner) andfast data transfer from the main memoryor the Compact Flash memory card (6500).

6200 6500

• Dedicated key for each test for ‘one-touch’testing

• Pre-set pass/fail levels to save time• Large backlit display for easy reading

As 6200 but also with:• Integral QWERTY keyboard for rapid

data entry • Slot for Compact Flash memory card for

back-up data storage and transfer to PC• Pre-set, auto-test sequences for user

convenience

Features

Measurement functionsL N Mains VoltsOutside Limits IndicatorsNull out facility for earth bond leadProtective Earth Resistance PE (200mA)Protective Earth Resistance PE (25A)Insulation 500V dcProtective Earth Conductor Current Touch CurrentSubstitute Leakage CurrentAppliance Power kVAAppliance Load CurrentSeven Segment Custom LCDGraphical LCDBack LightCompact Flash Card receptacleSerial Port - Printing / Downloading

External printer outputFront Panel QWERTY Key pad

IEC Lead TestAuto-testingPass / Fail Level Programmable IndicatorsData StorageLimited Data StoragePolarity ChecksGraphical Help Menu On LineProgramme ModeReal time clock

Front panel results management230V BS1363 Test socket / 230V Mains BS1363 input power plug

6200 6500

Fluke 6200

Fluke 6500

Page 43: Fluke 2007

41

6000 Series PAT Testers

Touch Current TestDisplay Range 0 to 1.99 mA acAccuracy ± (4% + 2 counts)Resolution 0.01 mAInternal Resistance (via probe) 2 kMeasuring method ProbeThe appliance under test is energized at mains potential.

Substitute Leakage Current TestDisplay Range 0 to 19.99 mA acAccuracy ± (5% + 5 counts)Resolution 0.01 mATest Voltage 35 V ac ± 20%Operational Error 10%

Load/ Leakage Test: Load CurrentDisplay Range 0 to 13 AAccuracy ± (4% + 2 counts)Resolution 0.1 AThe appliance under test is energized at mains potential.

Load/Leakage Test: Load PowerDisplay Range 0 to 999 VA

1.0 kVA to 3.2 kVAAccuracy ± (5% + 3 counts)Resolution 1 VA (0 to 999 VA)

0.1 kVA (1.0 kVA to 3.2 kVA)The appliance under test is energized at mains potential.

Load/Leakage Test: Leakage CurrentDisplay Range 0.25 to 19.99 mAAccuracy ± (4% + 4 counts)Resolution 0.01 mAThe appliance under test is energized at mains potential.

PELV TestAccuracy at 50 Hz ± ( 2% + 3 counts)Overload protection 300 VrmsWarning threshold 25 Vrms

Specifications

Separate hard case The compact Fluke PAT testers are supplied with ahard carrying case that not only offers protectionduring transit but also includes extra storage spacefor accessories and other tools. They’re extremelylight, weighing approximately 3 kg (without case)and have integral carrying handles for extraconvenience.

Special PAT KitIf you need a complete PAT tester solution, a purpose made kit is available. Fluke 6500/UK Kit Contains:• 6500, Mainframe• EXTL 100, Extension lead test adaptor• SP Scan 15, Barcode scanner• Fluke PowerPat Plus• Pass 560R, Appliance pass labels• Fail 100S, Appliance fail labels APP 1000,

Barcode appliance number labels

(Kit contents may vary per country)

Display ScreensSize (HxWxD): 200 mm x 275 mm x 100 mmWeight: 3 kgTwo Years Warranty

Recommended Accessories

Fluke PowerPat Plussoftware

SP1000-02Mini printer

SP-SCAN-15Barcode scanner(6500 Fluke only)

EXTL100-02Extension Test Lead Adapter

PASSAppliance 560R

Pass Labels

BDST3 Snap TagsCable Tie

BDST4 Snap TagsClip On

The accuracy specification for the display range is defined as ± (%reading + digit counts) at 23 °C ± 5 °C, 75 % RH.Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracyspecification) per °C. The measurement range meets the service operating errors specified in EN61557-1: 1997,EN61557-2: 1997 , EN61557-4: 1997.

Power-on TestThe test indicates reversed L-N, missing PE, andmeasures the mains voltage and frequency.Display Range 90 V to 264 VAccuracy at 50 Hz ± (2% + 3 counts)Resolution 0.1 V (1V - model 6200)Input Impedance > 1 M // 2.2 µFMaximum Input Mains Voltage 300 V

Earth Bond Test (Rpe)Display Range 0 to 19.99 Accuracy ± (5% + 4 counts)(after Bond Test zeroing)Resolution 0.01Test Current 200 mA ac -0% +40% into

1.9925 A ac ± 20% into 25 mat 230 V

Open Circuit Voltage > 4 V ac, < 24 VacBond Test Zeroing can subtract up to 1.99

Insulation Test (Riso)Display Range 0 to 299 MAccuracy ± (5% + 2 counts) from 0.1

to 50 M±(10% + 2 counts) from 50to 299 M

Resolution 0.01 M (0 to 19.99 M )0.1 M (20 to 199.9 M )1 M (200 to 299M )

Test Voltage 500 V dc –0% +25% at500 k load

Test Current >1 mA at 500 k load,< 15 mA at 0

Auto discharge time < 0.5 s for 1 µFMax. Capacitive Load operational up to 1 µF

Substitute Leakage Current Test Earth Bond Test (RPE)

Insulation Test (RISO) Touch Current Test

Page 44: Fluke 2007

Indoor Air Quality Tools

In response to the growing importance of air quality in buildings,workplaces and homes, Fluke offers you a range of tools that monitortemperature, humidity, air velocity, particulate, and carbon monoxidelevels. These tools help you to quickly and easily troubleshoot andmaintain indoor air quality, as well as to verify the efficient operationof heating, ventilation and air conditioning systems.

42

Page 45: Fluke 2007

975 AirMeter

43

Included AccessoriesA4 alkaline batteries (3), Users Manual,Calibration Cap, FlukeView Forms Software,Power Adapter, International Power Plugs,Air Velocity Probe (Fluke 975V only)

Ordering InformationFluke 975 AirMeterFluke 975V AirMeter with Velocity

Combined inspection tool for complete airquality inspections.

The Fluke 975 AirMeter combines five airmonitoring tools into one, rugged and easy-to-use handheld tool. Use the Fluke975 to verify the efficient operation ofheating, ventilation and air conditioningsystems, and test for dangerous carbonmonoxide leaks in all types of buildings.

• Simultaneously measures, logs, anddisplays temperature, humidity, CO2, andCO on a bright, backlit LCD display

• One-touch air flow and velocitymeasurements with available probe

• Min/Max/Average on all measured andcalculated readings

• Audible and visual threshold alarms• Multi-language user interface• Extensive discrete or continuous data

logging capacity, down-loadable to PCvia USB interface

Feature

Measured specifications

Temperature

Relative humidity

Air velocity

CO2

CO

Calculated specifications

Dew point temperature

Wet bulb temperature

Volume flow rate (in a duct)

% outside air (based on temperature)

% outside air (based on CO2)

Range Display resolution Accuracy

-20 °C to 60 °C 0.1 °C ± 0.9 °C from 40 °C to 60 °C± 0.5 °C from 5 °C to 40 °C± 1.1 °C from -20 °C to 5 °C

10 % to 90 % RH 1 % ± 2 % RH (10 % RH non-condensing to 90 % RH)

50 fpm to 3000 fpm 1 fpm 4 % or 4 fpm*0.25 m/sec to 0.005m/sec 3 % or 0.015 m/sec* 15 m/sec whichever is greater

*Accuracy specification only validfor velocity readings above 50 fpm.

0 to 5000 ppm 1 ppm Warm up time 1 min (5 minutes for full specification)2.75 % + 75 ppm

0 to 500 ppm 1 ppm ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH

-44 °C to 57 °C 0.1 °C ± 1 °C when temp: -20 °C to 60 °CRH: 40 % to 90 %± 2 °C when temp: -20 °C to 60 °CRH: 20 % to 40 %± 4 °C when RH: 10 % to 20 %

-16 °C to 57 °C 0.1 °C ± 1.2 °C when RH: 20 % to 90 %temp: -20 °C to 60 °C± 2.1 °C when RH: 10 % to 20 %

0 to 3,965 M3/m 0.001 M3/min N/A: The volume flow (0 to 140,000 cfm) (1 cfm) calculation will be a simple average

of the data points times the ductarea

0 to 100 % 0.1 % N/A

0 to 100 % 0.1 % N/A

Recommended Accessories

Fluke 975

Operating temperature (CO and CO2 sensors): -20 °C to 50 °COperating temperature (all other functions): -20 °C to 60 °CStorage temperature: -20 °C to 60 °CHumidity: 10% to 90%Altitude: Up to 2000 m

Shock and vibration: MIL-PRF-28800F,Class 2Battery: Rechargeable Li-Ion (primary),three-AA (backup)Weight: 0.544 kgSize (HxWxD): 28.7 cm x 11.43 cm x 5.08 cmData logging: 25,000 records (continuous), 99 records (discrete)Multilanguage interface: English, French,Spanish, Portuguese and GermanTwo-year warranty

Specifications

(Check the Fluke web for detailed specifications)

975VPAirMeter Velocity

Probe

New

Page 46: Fluke 2007

983 Particle Counter

44

Included AccessoriesCertificate of Calibration (NIST)Isokinetic probeZero count filterWindows-compatible software downloadutilityDB9 to RS-232 adapter and cableHigh purity tubing1/8 in. hose barb adapterPower supplyOperation manualHard molded carrying case

Ordering InformationFluke 983 Particle Counter

The Fluke 983 Particle Counter simulta-neously measures and displays six channelsof particle size distribution, temperatureand humidity. This compact, lightweight,self-contained tool allows for one-handedoperation. As the Fluke 983 doesn’t requirelevel holding, it can make accuratemeasurements in any position. The 8 hourrechargeable battery together with a large5000 sample record allows for complete airquality surveys in one go. The Fluke 983 isthe ideal tool for determining sizedistribution of airborne particles or trackingdown a particle source.

• Simultaneously measure and display 6 channels of particle sizes, temperatureand humidity

• Measure particle size down to 0.3 µm• Selectable sample time, count data,

programmable delay• Store 5000 records of date, time, counts,

relative humidity, temperature, samplevolumes, alarms and location label

• Upload stored data to a PC with includedsoftware

• Compact, self-contained package allowsfor one-handed operation

• Intuitive, easy to use user interface• Always ready to run, with no fluids to refill• Backlit LCD for use in any lighting

condition• 8 hour rechargeable NiMH battery• Protective holster

Specifications

Operating temperature: 10 °C to 40 °C, 20 % to90 % relative humidity, non-condensingStorage temperature: -10 °C to 50 °C, up to 90% relative humidity, non-condensingPower: AC adapter, 90 to 250 V AC, 50 to 60 HzBattery life/recharge time: 8 hours/2 hours

Rechargeable battery: NiMH, 4.8V at 4.5 Ah;replaceableSize (HxWxD): 209 mm x 114 mm x 57 mmWeight: 1 kgWarranty: 1 year

Easy to use tool for troubleshooting andmaintaining indoor air quality

0.3, 0.5, 1.0, 2.0, 5.0, 10.0 µm

0.1 cfm (2.83 L/min) controlled by internal pump

Concentration, totalize, audio

50 % @ 0.3 µm; 100 % for particles > 0.45 µm (per JIS B9921:1997)

1 count/5 minute (per JIS B9921:1997)

5 % at 2,000,000 particles per ft3

± 7 %, 20 % to 90 %, non-condensing

± 3 °C, 10 °C to 40 °C (50 °F to 104 °F)

5000 sample records (rotating buffer) of date, time, counts, relative humidity,temperature, sample volumes, alarms, label

Counts, low battery, sensor fail

0 to 24 hours

Isokinetic probe

RS-232 and RS-485 via RJ-45

PSL particles in air (NIST traceable)

6 size channels

Flow rate

Count modes

Counting efficiency

Zero count

Coincidence loss

Relative humidity

Temperature

Data storage

Alarms

Delay time

Sample inlet

Interface

Calibration

Fluke 983

Page 47: Fluke 2007

971 Temperature Humidity MeterCarbon Monoxide Meters

45

Included AccessoriesFluke CO-220 + CO-210:

C50 soft carrying case andbattery

CO-210: cord to plug into a digitalmultimeter

Ordering InformationFluke 971 Temperature Humidity MeterFluke CO-220 Carbon Monoxide MeterCO-205 Aspirator KitCO-210 Carbon Monoxide Probe

Other useful tools

Quickly take accurate humidity andtemperature readings in the air. Temperatureand humidity are two important factors inmaintaining optimal comfort levels andgood indoor air quality. The Fluke 971 isinvaluable for facility maintenance andutility technicians, HVAC-service contractors,and specialists who assess indoor air quality(IAQ). Lightweight, rugged, and easy tohold, the Fluke 971 is the perfect tool formonitoring problem areas.

• Simultaneously measures humidity andtemperature

• Measures dew point and wet bulb• 99 record storage capacity• Min/Max/Avg Data Hold• Ergonomic design with built-in belt clip

and protective holster• Backlit, dual readings display • Twist-open protective cap• Low battery indicator

Specifications

Operating temperature: Temperature: -20 °C to 60 °CHumidity: 0 °C to 60 °CStorage temperature: : -20 °C to 55 °CBattery life: 4 AAA alkaline, 200 hours

Safety: Complies with EN61326-1Weight: 0.188 kg Size (HxWxD): 194 mm x 60 mm x 34 mmOne Year Warranty

Fluke 971Temperature Humidity Meter

-20 °C to 60 °C

± 0.5 °C

± 1.0 °C

0.1 °C

500 ms

NTC

5% to 95% R.H.

± 2.5 % R.H.

± 5.0 % R.H.

Electronic capacitance polymer film sensor

99 points

For 90% of total range – 60 sec with 1 m/s air movement

Temperature range

Temperature accuracy

0 °C to 45 °C

-20 °C to 0 °C and 45 °C to 60 °C

Resolution

Response time (temperature)

Temperature sensor type

Relative humidity range

Relative humidity accuracy

10 % to 90 % R.H. @ 23 °C

<10 %, > 90 % R.H. @ 23 °C

Humidity sensor

Data storage

Response time (humidity)

Fluke 971

Carbon Monoxide Meters

CO-220 Carbon Monoxide MeterThe CO-220 Carbon Monoxide Meter makes it easy to takequick and accurate measurements of CO levels. A large, backlitLCD display shows CO levels from 0 to 1000 PPM. The MAXHold function stores and displays the maximum CO level. 1 year warranty.

CO-210 Carbon Monoxide ProbeAs an accessory to a digital multimeter with dc mV inputs, the Fluke CO-210 displays CO levels from 0 to 1000 PPM. As a standalone device, the LED indicator and beeper triggerwith increasing frequency as the CO level rises. 1 year warranty.

CO-205 Aspirator KitAllows flue gas samples up to 371°C to be drawn with the CO-210 or CO-220 for carbon monoxide measurement. 1 year warranty.

Fluke CO-220

Fluke CO-210

Fluke CO-205

Fluke 561Combined Contactand Non-contactThermometerSee page 49.

Fluke 902True RMS ClampMeter withTemperatureMeasurementSee page 22.

Page 48: Fluke 2007

Digital Thermometers

For troubleshooting systems where temperature is a critical symptom,our digital thermometers provide you with laboratory accuracywherever you need it. We offer a choice of non-contact, laser-guidedinfrared thermometers for safely getting at hard-to-reach, electricallylive or particularly hot targets, and contact thermometers with a fullrange of thermocouple probes.

46

Page 49: Fluke 2007

570 Series Precision Infrared Thermometers

47

Included AccessoriesFluke 572: Hard case, 2 batteries Fluke 574: Hard case, 2 batteries,Thermocouple K probe, 220V power supply,DataTemp software, RS232 cableFluke 576: Hard case, 2 batteries,Thermocouple K probe, DataTemp software,USB cable.

Ordering InformationFluke 572 Precision Infrared ThermometerFluke 574 Precision Infrared ThermometerFluke 576 Precision Infrared ThermometerFluke 572CF Precision Infrared Thermometer

with close focus optionFluke 574CF Precision Infrared Thermometer

with close focus optionFluke 576CF Precision Infrared Thermometer

with close focus optionAN5

Analog data cableC570

See page 94

Measure temperature with ease and precision

The Fluke 570 series are the most advanced IRnon-contact thermometers, and are ideal forpredictive and preventative maintenanceapplications. Offering a broad temperature range and a truedimension laser sighting system for precisetargeting resulting in more accuratemeasurements. When requiring analysis anddocumentation use the 100-point data loggingand software for graphing and analysis. Thetop-of-the-range Fluke 576 even has a built-indigital camera that photographs the locationwhen the temperature measurement is made.From close-up electrical connections, to far-distance room balancing checks, the Fluke 570series can take IR temperature measurementswith ease and precision.

• Enhanced optics allows measurements ofsmaller objects from farther away

• True Dimension™ three-dot laser sightingsystem highlights the true diameter ofmeasurement spots at all distances

• Adjustable emissivity setting and 30 pre-setcommon material values for more accuratemeasurements

• 100 data point memory for storage ofmeasurements (Fluke 574, 576) andphotographic images (Fluke 576)

• Instantly captures photographs of temperaturemeasurement locations for improveddocumentation (Fluke 576 only)

Features

Temperature rangeOptical resolution

3 dot laser beam for accurate targetingAdjustable emissivityBar graph displayBacklit LCD display Use selectable ºC or ºFAudible and visible Hi/Lo AlarmMIN/MAXAVG/DIF readingsDatalogging (number of measurements)PC interfaceBuilt-in Digital camera

Fluke 572

572 574 576-30 to 900°C

Standard: 60:1Close focus: 50:1

-/ / /

100 100RS232 USB

Recommended Accessories

Temperature rangeResponse timeResolutionRepeatabilityAccuracy: (assumes ambient operating temperatureof 23 ºC to 25 ºC )Typical distance to target Emissivity

572 574 576-30 to 900°C

250ms (95 % of reading)0.1°C of reading up to 900°C±0.5% of reading or ±1°C*

±0.75% of reading, ±0.75°C *

10,5 mDigitally adjustable from 0.10 to 1.0 by 0.01

Specifications

*whichever is greater.

Battery Life:Fluke 572, 574: 10 hours typicalFluke 576: 8 hours typical (13 hours with photographic mode off)

Size (HxWxD):Fluke 572/574: 200 mm x 170 mm x 55 mmFluke 576: 240 mm x 170 mm x 55 mm

Weight: Fluke 572: 0.480 kgFluke 574: 0.480 kgFluke 576: 0.580 kg

Two years warranty

Fluke 576

Fluke 574

Page 50: Fluke 2007

Included AccessoriesFluke 61: 9V BatteryFluke 62: 9V Battery, storage holsterFluke 63, 66 and 68: Hard carrying case,

9V batteries

Ordering informationFluke 61 Infrared ThermometerFluke 62 Mini Infrared ThermometerFluke 63 Infrared ThermometerFluke 66 Infrared ThermometerFluke 68 Infrared Thermometer

60 Series Infrared Thermometers

48

Point, press and read temperature

The Fluke 60 Series non-contact thermo-meters are the ideal professional diagnostictools for quick and accurate temperaturemeasurements.These handheld tools are ideal formeasuring surface temperatures of rotating,hard-to-reach, electricity live or dangerouslyhot targets like electrical motors and –panels, and heating and ventilation systems.The laser sighting system guidesmeasurements to the right target and inless than a second, the large temperaturedisplay provides a readout of the surfacetemperature.

The 60 Series IR thermometersfeature:• Laser guided sighting system for easy

targeting with 1% accuracy• Up to 12 points datalogging with Min,

max average functions• Up to 50:1 optical resolution• Choice between models with fixed or

adjustable emissivity• Backlit display for easy reading in the dark• Temperatures up to 760°C

C23See page 94

80PR-60See page 93

H6See page 95

Specifications

Features

Battery Life: Fluke 66 and 68: 20 hours with laser and backlight on 50%Fluke 63: 10 hours with laser and backlight onFluke 62: 12 hours with laser and backlight onFluke 61: 12 hours with laser and backlight on

Size (HxWxD): Fluke 63, 66 and 68: 200 mm x 160 mm x 55 mmFluke 62: 152 mm x 101 mm x 38 mmFluke 61: 184 mm x 45 mm x 38 mm

Weight: Fluke 63, 66 and 68: 0.320 kgFluke 62: 0.200 kgFluke 61: 0.227 kg

Fluke 62: 2 years warrantyOther models: one year warranty

61 62 63 66 68

Flat grip Pistol grip Pistol grip Pistol grip Pistol grip

-18 to 275°C -30 to 500 °C -32 to 535°C -32 to 600°C -32 to 760°C

8:1 10:1 12:1 30:1 50:1

Max MAX only

Form factor

Temperature range

Optical resolution

Laser beam for accurate targeting

Backlit LCD display

Use selectable °C or °F

MIN/MAX/AVG/DIF readings

Datalogging

Hi/Lo Alarm

Adjustable emissivity

61 62 63 66 68-18 to 275°C -30 to 500 °C -32 to 535°C -32 to 600°C -32 to 760°C

<500ms <500ms 0.5 second 0.5 second 0.5 second (95 % of reading)

0.2°C 0.2°C 0.2°C 0.1°C 0.1°C

± 2% ±0.5% ± 0.5% ± 0.5% ± 0.5% or ± 2°C* or < ±1°C* or ± 1°C* or ± 1°C* or ± 1°C*

For targets at: For targets at: For targets at: For targets at: For targets at:-18 to -1°C: ± 3°C 10 °C to 30 °C: ±1 °C -32 to -26°C: ± 3°C -32 to -26°C: ± 3°C -32 to -26°C: ± 3°C -1 to 275°C: ± 2% ± 1.5% of reading -26 to -18°C: ± 2.5°C -26 to -18°C: ± 2.5°C -26 to -18°C: ± 2.5°C

of reading or ± 2°C* or ± 1.5°C whichever -18 to 23°C: ± 2°C -18 to 23°C: ± 2°C -18 to 23°C: ± 2°C is greater over 23°C -510°C: ± 1% For targets above For targets above the balance of of reading or ± 1°C* 23°C: 23°C:

the range For targets ± 1% of reading ± 1% of readingabove 510°C: or ± 1°C* or ± 1°C*

± 1.5% of reading

Up to 1m Up to 1,5 m Up to 2 m 5 m 8 m

Fixed at 0.95 Pre-set to 0.95 Fixed at 0.95 Digitally adjustable Digitally adjustablefrom 0.1 to 1.0 from 0.1 to 1.0

by 0.01 by 0.01

Range

Response time

Resolution

Repeatability(% of reading)

Accuracy:(assumes ambient

operating temperature

of 23°C)

Typical distance totarget

Emissivity

* whichever is greater

Recommended Accessories

Fluke 68

Fluke 66

Fluke 63

Fluke 62

Fluke 61

The Fluke FoodPro™ thermometerseries provide advanced temperaturemeasurement solutions for thefoodservice industry. Check theFluke web for more information.

Page 51: Fluke 2007

561Multipurpose Thermometer

49

H6See page 95

80-PK-1See page 92

80PK-8See page 92

80PK-25See page 92

Recommended Accessories

Included accessoriesThermocouple K-type Velcro pipe probe,hand carrying case, 2 AA batteries and usermanual with measurement guide.

Ordering informationFluke 561 HVACPro Thermometer

Combined Infrared and Contact ThermometerThe easy-to-use Fluke 561 combines thetemperature measurement functions thatprofessionals need for various heating,ventilation and air conditioning monitoringjobs, all in one tool. It provides both non-contact infrared (IR) and contacttemperature measurements, replacing theneed for multiple test tools. Use the IRthermometer to measure hot, moving,electrically energized and hard-to-reachobjects instantly without the need for aladder or having to shut down equipment.Use the unit’s Velcro pipe probe for easycontact measurements, or plug in anyindustry-standard K-type mini-connectorthermocouple you already have.

• IR thermometer for quick measurementsup close or at a distance

• Single-point laser sighting• Easy emissivity adjustment for measuring

pipes and ducts more accurately• Includes a Velcro pipe probe for super-

heat and sub-cooling as well as othersurface contact measurements

• Also compatible with all standard mini-connector K-type thermocouples

• MIN, MAX and DIF temperature readings• Lightweight (only 340 grams) and

portable• Includes measurement guide

Temperature range -40° to 550°C

Display resolution 0.1° of reading

D:S (Distance to spot size) 12:1

Easy emissivity selector Adjustable with three settings: low (0.3), medium (0.7), high (0.95)

Display accuracy (Assumes ambient operating ± 1.0% of reading or ± 1°C, whichever is greater;temperature of 23° to 25°C) below 0°C, ± 1°C, ± 1°/1°

Response time 500 mSec (95% or reading)

Repeatability ± 0.5% of reading or ± 1°C, whichever is greater

Spectral focus 8 µm to 14 µm

Laser sighting Single-point laser

Laser shutoff Laser turns off above ambient temperature of 40°C

Laser power Class 2 (II) operation; output ‹ 1 mW, wavelength 630 nm to 670 nm

Relative humidity 10% to 90% RH non-condensing, at < 30°C

Power 2 AA batteries (alkaline or NiCD)

Display hold 7 seconds

Backlit display Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC),low battery, F/C indicator, and Scan/Hold options

Operating temperature 0° to 50°C

Storage temperature -20 to 65°C

MAX, MIN, DIF temperatures Yes

Thermocouple type K mini-adapter input Yes, compatible with industry standard type K probes with mini-connector

Thermocouple type K Velcro pipe probe Yes, with a temperature range of 0° to 100°C and accuracy of ± 2.2°C

Measurement guide Yes

Specifications

Fluke 561

Battery Life (alkaline): 12 hoursSize (HxLxW): 176,9 mm x 163,6 mm x 51,8 mm

Weight: 340 gramsTwo years warranty

The Fluke 561 includes everything you need for immedi-ate inspections.

New

Page 52: Fluke 2007

C25See page 94

80PK-26See page 92

80PK-25See page 92

FVF-SC1See page 97

TPAKSee page 97

50 Series II Thermometers

Laboratory accuracy. Wherever you go.

Additional features for the 53 and 54 Series II:• Data Logging up to 500 points of data

with user adjustable recording interval• Real time clock captures the exact time of

day when events occur• Recall function allows logged data to be

easily reviewed on the meter display• IR communication port allows data to be

exported to optional FlukeView®

Temperature PC software

Features

Specifications

Recommended Accessories

Battery life: 1000 hours typical, AASize (HxWxD): 173 x 86 x 38 mm

Weight: 0.4 kgThree Year Warranty

50

Included AccessoriesImpact absorbing holsterTwo bead probe thermocouples 80PK-1(54+52)One bead probe thermocouple 80PK-1(51+53)

Ordering InformationFluke 51 II ThermometerFluke 52 II ThermometerFluke 53 II ThermometerFluke 54 II ThermometerFVF-SC1 FlukeView Forms

Software includinginterface cable

51 II 52 II 53 II 54 II

Thermocouple types J,K,T,E J,K,T,E J,K,T,E,N,R,S J,K,T,E,N,R,S

Number of inputs Single Dual Single Dual

Time stamp Relative Time Relative Time Time of Day Time of Day

Splash/Dust resistant

Dual display with backlight

Min/Max/Avg recording

(T1-T2) True differential

Data logging up to 500 points

IR data port for interface to PC

Compatible with optional FlukeView Software

Temperature range:

J-type Thermocouples -210°C to 1200°C (-346°F to 2192°F)

K-type Thermocouples -200°C to 1372°C (-328°F to 2501°F)

T-type Thermocouples -250°C to 400°C (-418°F to 752°F)

E-type Thermocouples -150°C to 1000°C (-238°F to 1832°F)

N-type** Thermocouples -200°C to 1300°C (-328°F to 2372°F)

R** and S-type** Thermocouples 0°C to 1767°C (32°F to 3212°F)

Temperature accuracyAbove –100°C (-148°F):

J, K, T, E, and N-type** ± [ 0.05% + 0.3°C (0.5°F) ]

R** and S-type** ± [ 0.05% + 0.4°C (0.7°F) ]

Below –100°C (-148°F):

J, K, E, and N-types ± [ 0.20% + 0.3°C (0.5°F) ]

T-type ± [ 0.50% + 0.3°C (0.5°F) ]

**Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type thermocouples.

The Fluke 50 Series II contactthermometers offer fast response andlaboratory accuracy (0.05% + 0.3°C) in a rugged handheld test tool.

• Large backlit dual display shows anycombination of T1, T2 (52 and 54 only),T1-T2 (52 and 54 only) plus MIN, MAX, or AVG

• Relative time clock on MIN, MAX, andAVG provides a time reference for majorevents

• Electronic Offset function allowscompensation of thermocouple errors tomaximize overall accuracy

• Readout in °C, °F, or Kelvin (K)• Sleep mode increases battery life• Battery door allows easy battery

replacement without breaking thecalibration seal

Fluke 51 II Fluke 52 II Fluke 53 II

Fluke 54 II

Page 53: Fluke 2007

Thermal Imagers

Fluke offers a complete range of handheld thermal imagers, rangingfrom the affordable Fluke Ti20 to the high-precision Fluke Ti40/Ti50IR FlexCam® Series that delivers the largest and sharpest images. The Ti20 is for technicians doing route-based infrared inspections andeveryday maintenance, whereas the IR FlexCam Series is designed forPredictive Maintenance (PdM) experts, process engineers, andconsultants who need the best thermal imager available.

51

Page 54: Fluke 2007

Electric motors and pumpsHot spots may be an early indicator of motorwinding problems. Elevated temperatures candamage winding insulation, resulting inoperational inefficiencies and premature motorfailure. An overheated motor may be an indicationof an underrated motor in the application,insufficient cooling or electrical power problems.

Bus bars and fuse boxesTemperature differences between phases mayindicate unbalanced loads, harmonics, componentproblems, bad connections or bad wiring. Theseconditions can result in increased energy cost andcan damage cables or machines or possibly causefire. Even small temperature differences betweenphases should be investigated to determine theroot-cause.

Rotating machineryBall bearings showing an increased temperatureare an indication that either the quality of thelubricant is deteriorating or there is pooralignment between the motor and shaft. Theseproblems can cause the bearings to fail, or amotor or pump to overheat.

Ti Series Thermal Imagers

52

Built for the industry, Fluke Ti SeriesThermal Imagers can carry out inspectionsanytime, anywhere and anyplace. In factthermal imagers can be used anywheretemperature plays a role. Some industryapplications are:

Electrical power distribution systems• Three-phase systems• Overhead power cables• Distribution panels• Fuses, wiring and connections• Power/utility

Electro-mechanical equipment• Motors and pumps• Bearings, pulleys and belts

Process monitoring• Process control equipment• Tanks, pipes, valves, steam traps and

vessels

Facility maintenance• HVAC systems• Buildings and roofs

Other• Electronic design• And many more

Maximizing return on investmentImplementing a predictive maintenanceprogram using thermal imaging cansignificantly reduce both maintenance andproduction costs. Unplanned productiondowntime can be minimized with the FlukeTi Series, resulting in better labourproductivity, reduced scrap and smallerreplacement part inventory. Establishing aneffective IR predictive maintenanceprogram is straightforward. The Ti20 andthe InsideIR software facilitate creatinginspection routes that can be uploaded tothe instrument. With clear step-by-step on-camera routing instructions, anymaintenance technician can perform theinspection.

Radiometric measurement – the“data behind the picture" The Fluke Ti Series is fully radiometric.Fully radiometric thermal imagers captureand store calibrated temperature data forthousands of points in a thermal imagematrix. This makes it possible to performdetailed analysis and change keyparameters like emissivity or temperaturelevel and span either in the field on thecamera or later using the PC software.

The solution for industrial maintenanceapplications

Ti20 Ti40 Series Ti50 SeriesDetector type 128 x 96 160 x 120 320 x 240Field of View (FOV) 20º horizontal 23º horizontal 23º horizontal

x 15º vertical x 17º vertical x 17º verticalOptional lenses

Spatial resolution (IFOV) 2.7 mrad 2.6 mrad 1.3 mradThermal sensitivity 0.2 ºC down to 0.08 ºC down to 0.05 ºCTemperature range 350 ºC up to 600 ºC* up to 600 ºCDigital display 3” LCD 5” LCD 5” LCDVideo output

Palettes Choice of 4 Choice of 8 Choice of 8IR-Fusion Option OptionPdM routing function

Fully radiometric

Software InsideIR SmartView SmartViewStorage medium 50 images internal flash >1000 IR images >1000 IR images

on compact flash card on compact flash card

*1200 ºC option available

FREE thermal imaging application DVDThis DVD covers the principles of thermalimaging and looks at using this powerfultroubleshooting technology in electrical,electro-mechanical and process controlapplications. Order your copy atwww.fluke.co.uk/DVD orwww.fluke.eu/DVD

Selection Table

Page 55: Fluke 2007

Ti20 Thermal Imager

53

The Ti20 brings the powerful diagnosticcapabilities of infrared thermal imagingtechnology within reach of a wider rangeof industrial applications. The unit is fullyradiometric for detailed temperatureanalysis and tracking of criticalcomponents. It is easy to operate by theservice and maintenance personnel whoknow and understand the equipment best.

• 128 x 96 detector provides a clearthermal image with accurate temperaturemeasurements up to 350 °C

• Fully radiometric for detailed temperatureanalysis and tracking of criticalcomponents

• Large color LCD displays unclutteredimage with data and routing instructions

• Facilitates one-handed point, shoot andimage capture operation

• Assists fast inspections with clear on-screen step-by-step routing instructions

• Protected against dust and moisture (IP54 rated) to withstand harsh industrialenvironments

• Provides 3 hours continuous operationper battery charge (2 battery packsdelivered with the unit)

• Includes InsideIR™ software for unlimiteduse by every member of the maintenanceteam (no software license fees)

• Comes complete with all necessaryaccessories and professional applicationtraining material to ensure a fast returnon investment

The thermal imager for everyday maintenance and inspection

Imaging performance

Field of view (FOV) 20º horizontal x 15º vertical

Spatial resolution (IFOV) 2.73 mrad

Min focus distance 0.15 m

Thermal sensitivity (NETD) 0.2 °C at 30 °C

Image frequency 9 Hz

Focus Manual

Detector type 128 x 96 Focal Plane Array, Uncooled Microbolometer

Spectral band 7.5 µm to 14 µm

Temperature measurement

Calibrated temperature range -10 ˚C to 350 ˚C

Accuracy ±2° C or 2% (whichever is greater)

Measurement modes Auto and manual level and span adjustment

Emissivity correction 0.1 to 1.0 (0.01 increments)

Image presentation

Digital display 3" large color LCD

LCD backlight Selectable On/Off

Palettes Grayscale, reverse grayscale, rainbow, ironbow

Image and data storage

Storage medium 50 images internal flash

File formats supported 14 bit measurement data included. Exportable JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, EMF

Interfaces and software

Interface USB 2.0 (High speed)

Software InsideIR; Full analysis and reporting software included

Laser

Classification Class II

Controls and adjustments

Set-up controls Date/time, temperature units C/F, LCD intensity (high/normal/low),

On-screen Indicators Battery status, real time clock and center point temperature, range and span indication and high andlow alarm settings

Specifications

(Check the Fluke web for detailed specifications)

Battery life: 3 hours per rechargeable battery (2 included)Water and dust resistant: IP54Size (HxWxD): 254 mm x 102 mm x 178 mmWeight: 1.2 kgOne Year Warranty

Ti20-CCCar charger

Ti20-VisorSun Visor

Ti20-RBPRechargeablebattery pack

Recommended Accessories

Included AccessoriesHard carrying caseSoft-sided carrying case2 Rechargeable battery packs1 AA battery caseAC/DC power adapterUSB communication cableWrist strapInsideIR reporting and analysis software Interactive CD with training materialsGetting Started Guide

Ordering InformationFluke Ti20 Thermal Imager

Fluke Ti20

Quickly and easily create reports with the InsideIR software

Page 56: Fluke 2007

Included AccessoriesHeavy duty carrying case2 rechargeable battery packsBattery chargerAC adapter (for Ti45 and Ti55 only)Video cable512 MB compact flash cardCompact flash card reader and USB cablePCMCIA compact flash card readerNeck strapSmartView reporting and analysis softwareon CDUser manual on CD

Ordering Information*Fluke Ti40-20 IR FlexCam Thermal

ImagerFluke Ti40FT-20 IR FlexCam Thermal

Imager with IR-Fusion Fluke Ti45-20 IR FlexCam Thermal

ImagerFluke Ti45FT-20 IR FlexCam Thermal

Imager with IR-FusionFluke Ti50-20 IR FlexCam Thermal

ImagerFluke Ti50FT-20 IR FlexCam Thermal

Imager with IR-Fusion Fluke Ti55-20 IR FlexCam Thermal

ImagerFluke Ti55FT-20 IR FlexCam Thermal

Imager with IR-Fusion

*For ordering information of optional lensescheck the Fluke web.

Ti40/Ti50 Series IR FlexCam®

Thermal Imagers

The thermal imagers for professionalsdemanding the best

The Fluke IR FlexCams produce theindustry’s largest and sharpest thermalimages. The FT models feature innovativeIR-Fusion technology which links a realworld visual image with a thermal image.

The innovative 180º articulating lens makesit possible to view and capture images inareas with poor accessibility.

IR-Fusion™ TechnologyIR-Fusion technology simultaneouslycaptures pixel-for-pixel infrared and visiblelight images and allows full imageoptimization with 5 different on-camera as

well as software viewing modes. With theintegrated laser pointer visible on theimages, precise and accurate (faulty)component identification is very easy.

Features

Alpha Blending

IR/Visible Alarm Full Visible Light

Full IR Picture-in-Picture

Fluke Ti40, Ti45, Ti50, Ti55

Fluke Ti40FT, Ti45FT, Ti50FT, Ti55FT

Ti40 Ti45 Ti50 Ti55

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• •

• •

• •

FT model FT model FT model FT model

FT model FT model FT model FT modelPiP only

FT model FT model

FT model FT model FT model FT model

FT model FT model FT model FT model

54

New

180º articulating flexible lens to view images in every situation

Choice of 3 interchangeable lenses to cover every application

Large 5" high contrast color LCD for a clear picture independent oflighting conditionsFully radiometric for detailed temperature analysis and tracking

SmartFocus for best image quality and accurate temperaturemeasurementsWindows® CE based menu structure for ease of use

Personalized instrument set-up for multiple use

CompactFlash memory cards to store over 1000 IR images plus fullyradiometric temperature dataSmartView reporting and analysis software included

AutoCapture for making intermittent problems visible

On-board analysis functions

User defined text annotations for simplified reporting

Built-in visible light (digital) camera

IR-Fusion blending thermal and visible light images to easilypinpoint suspect components IR/Visible Alarm

Laser pointer for easy targeting

Flash and torch light for high quality images in dark environments

New

Page 57: Fluke 2007

103232Anti-glare Hood

104543Car charger

Ti-SBCBattery Charger

Ti-SBPRechargeable Battery

Pack

Ti40/Ti50 Series IR FlexCam®

Thermal Imagers

55

Thermal Imaging performanceField of view (FOV)*Spatial resolution (IFOV)*Min focus distance*Thermal sensitivity (NETD) at 30 °CDetector data acquisition / Image frequencyFocusIR digital zoomDetector size Detector type

Spectral bandVisual Imaging performance (Fusion models only)On-camera operating modes- Picture-in-Picture- Full thermal, full visual light or merged thermal-visualimagesVisible light cameraVisible light digital zoom Temperature measurementCalibrated temperature range1200 ˚C High temperature option AccuracyMeasurement modes- Centerpoint, center box (area min/max, average)- Moveable spots/boxes- Isotherms, automatic hot and cold point detection,- Visible color alarm above and belowEmissivity correctionImage presentationDigital displayVideo outputPalettes

Optional lenses54 mm Telephoto lensField of view (FOV)Spatial resolution (IFOV)Min focus distance10.5 mm wide angle lensField of view (FOV)Spatial resolution (IFOV)Min focus distanceImage and data storageStorage mediumFile formats supportedInterfaces and softwareInterfaceIncluded softwareLaser (IR-Fusion models only)ClassificationLaser targeting

Controls and adjustmentsSet-up controlsImage controlsOn-screen indicators

Specifications

(Check the Fluke web for detailed specifications)

*standard 20 mm Germanium lens

Recommended Accessories

Battery life: 3 hours continuous operation (2 hours on FT models)Water and dust resistant: IP54Size (HxWxD): 162 mm x 262 mm x 101 mmWeight: 1.85 kgTwo Years Warranty

Ti40 Ti45 Ti50 Ti55

23º horizontal x 17º vertical2.60 mrad 1.30 mrad

0.15 m0.09 °C 0.08 °C 0.07 °C 0.05 °C

30 Hz/30 Hz 60 Hz/60 HzSmartFocus; one finger continuous focus

2x 2x 2x, 4x. 8x160 x 120 320 x 240

Focal Plane Array, Vanadium Oxide (VOx) UncooledMicrobolometer8 µm to 14 µm

• • • •Smartview • • •

only1280 x 1024 pixels, full color

2x 2x 2x, 4x. 8x

-20 to 350 ˚C -20 to 600 ˚C -20 to 350 ˚C -20 to 600 ˚C

•±2°C or 2 % (whichever is greater)

• • • •• •• •• •

0.1 to 1.0 (0.01 increments)

5" large high-resolution backlight LCDRS170 EIA/NTSC or CCIR/PAL composite video

Grayscale, grayscale inverted, blue red, high contrast,hot metal, ironbow, amber, amber inverted

High precision Germanium lens9º horizontal x 6º vertical

0.94 mrad 0.47 mrad0.6 m

High precision Germanium lens42º horizontal x 32º vertical

4.9 mrad 2.45 mrad0.3 m

Compact flash card (512Mb) stores over 1000 IR images 14 bit measurement data included. JPEG, BMP, PCX, PNG

Compact flash card reader includedSmartView; Full analysis and reporting software

Class IILaser dot visible on blended and visual image

Date/time, °C/°F, language, scale, LCD intensity Level, span, auto adjust (continuous/manual)

Battery status, emissivity, background temperatureand real time clock

SmartView™ SoftwareFluke SmartView™ software is included with eachFluke IR FlexCam® Thermal Imager. This powerfulsoftware is a modular suite of tools thatannotates, views, edits and analyzes IR images. It also generates fully customizable andprofessional-looking reports in a few easy steps.The IR-Fusion technology is fully supported.

Complete packageThe IR FlexCam thermal imagers are delivered asa complete package.

Building DiagnosticsFluke also offers a line of thermal imagers forBuilding Diagnostics, the IR Insight and the TiRSeries. Some typical applications are industrialroofing, moisture remediation, energy audits andhome inspection. For more information on thesethermal imagers please check the Fluke web.

Page 58: Fluke 2007

Power Quality Tools

In all types of businesses that rely on electrical and electronicequipment, power quality plays a critical role in maintainingconsistency and productivity. Fluke offers an extensive range of powerquality test tools for troubleshooting, preventive maintenance, andlong-term recording in industrial and utility applications. The toolsgive you the power to analyze every parameter, power-related eventor disturbance faster, safer and in more detail than ever before.

56

Page 59: Fluke 2007

Power Quality Selection Guide

57

FR

EE

DV

DPo

wer

Qua

lity

in I

ndus

tria

l App

licat

ions

Cove

rs t

he b

asic

s of

pow

er q

ualit

y an

d lo

oks

at t

he t

ools

and

insp

ectio

n te

chni

ques

us

ed t

o tr

oubl

esho

ot c

omm

on p

robl

ems.

Ord

er y

our

copy

at

ww

w.fl

uke.

co.u

k/D

VD

or

ww

w.fl

uke.

eu/D

VD

Ap

pli

cati

ons

1-Ph

ase

/ 3-

Phas

eFr

ontli

ne T

roub

lesh

ootin

gPr

edic

tive

Mai

nten

ance

Load

Stu

dy, P

Q S

urve

yCo

mpl

ianc

e (E

N50

160)

Long

-ter

m A

naly

sis

Feat

ures

Dis

play

Volta

ge C

hann

els

Curr

ent

Chan

nels

Incl

uded

Cur

rent

Pro

bes

Dus

t/W

ater

Res

ista

nce

Safe

ty R

atin

g

Soft

war

e

Batt

ery

Ope

ratio

n (h

ours

)R

ecor

din

g C

apab

ilit

y Ty

pica

l Rec

ordi

ng P

erio

d (D

ays)

Mem

ory

MIN

/MA

X/A

VG

Log

ging

Flic

ker

Har

mon

ics

Even

t Ca

ptur

eW

avef

orm

Cap

ture

Use

r-de

fined

Log

ging

Pow

er o

f M

easu

red

Sign

als

Sam

ple

Rat

e

Hig

h-sp

eed

Capt

ure

Rat

ePe

ak V

olta

geA

nal

ysis

Cap

abil

ity

Stat

istic

al A

naly

sis

(incl

udin

g E

N50

160)

Rep

ort

Gen

erat

orR

oot

Caus

e A

naly

sis

Acc

urac

yIE

C 61

000-

4-30

Cla

ss A

Com

plia

ntVo

ltage

RM

S

Curr

ent

RM

S (e

xclu

ding

cla

mp

unle

ss s

peci

fied)

Fluk

e 3

45

Fluk

e 4

3B

Fluk

e 4

35

Fluk

e 4

34

Fluk

e V

R10

1Fl

uke

173

5Fl

uke

174

3Fl

uke

174

4Fl

uke

174

5Fl

uke

176

0Po

wer

Qua

lity

Pow

er Q

ualit

y Po

wer

Qua

lity

Pow

er Q

ualit

y Vo

ltage

Eve

ntPo

wer

Log

ger

Pow

er Q

ualit

y Po

wer

Qua

lity

Pow

er Q

ualit

y Po

wer

Qua

lity

Clam

p M

eter

A

naly

zer

Ana

lyze

rA

naly

zer

Rec

orde

rLo

gger

Logg

erLo

gger

Rec

orde

r

1-Ph

ase

1-Ph

ase

3-Ph

ase

3-Ph

ase

1-Ph

ase

3-Ph

ase

3-Ph

ase

3-Ph

ase

3-Ph

ase

3-Ph

ase

Colo

r G

raph

ical

B&W

Gra

phic

alCo

lor

Gra

phic

alCo

lor

Gra

phic

alLE

DCo

lor

Gra

phic

alLE

Ds

LED

sLC

D a

nd L

ED

sLE

Ds

11

44

13

44

44

(8 w

ithou

tcu

rren

t)1

14

44

44

44

(0 w

ith8

volta

ge)

2000

A40

A /

3000

A F

lexi

s40

A /

15

A /

150

A /

15

A /

150

A /

15

A /

150

A /

15

A /

150

A /

20

0A /

100

0A

400A

Cla

mps

400A

Cla

mps

3000

A F

lexi

s15

00A

/15

00A

/15

00A

/Fl

exis

3000

A F

lexi

s30

00A

Fle

xis

3000

A F

lexi

sIP

40IP

51IP

51IP

51IP

65 (

exce

pt

IP65

IP65

IP50

IP50

batt

ery

hous

ing)

600

V C

AT I

V6

00V

CAT

III

1000

V C

AT I

II10

00V

CAT

III

300V

CAT

III

600

V C

AT I

II6

00V

CAT

III

600

V C

AT I

II6

00V

CAT

III

1000

V C

AT I

II

6

00V

CAT

IV

600

V C

AT I

V6

00V

CAT

IV

Fluk

eFl

ukeV

iew

Fluk

e Po

wer

Log

/ Fl

ukeV

iew

Fluk

eFl

uke

Fluk

eFl

uke

Fluk

e Fl

uke

PQ

Pow

er L

ogFl

ukeV

iew

Even

t V

iew

PQ L

ogPQ

Log

PQ L

ogPQ

Log

Ana

lyse

246.

57

724

540

min

utes

1 da

y1

wee

k1

mon

th1

wee

k1

mon

th1

mon

th3

mon

ths

3 m

onth

s3

mon

ths

3 m

onth

s2

MB

0.5

MB

16 M

B8

MB

32 k

B4

MB

8 M

B8

MB

8 M

B2

GB

9.6

kHz

12.8

kH

z &

20

.48

kHz

20.4

8 kH

z1/

2 cy

cle

10.2

4 kH

z10

.24

kHz

10.2

4 kH

z10

.24

kHz

10.2

4 kH

z15

.36

kHz

inte

grat

ed25

MH

z20

0 kH

z20

0 kH

z0.

5 or

10

MH

z 1

kV1.

25 k

V6

kV6

kV2.

5 kV

6 kV

±(1

%+

0.1%

Vno

m0.

5% V

nom

±2V

0-2

00V

, ±

(0.5

%+

0.1%

of

rang

e0.

1% o

f ra

nge

0.1%

of

rang

e0.

1% V

nom

10 c

ount

s)±

4V 0

-270

V10

cou

nts)

±(1

%+

±(0

.5%

(1%

(1%

+2%

of

rang

e 2%

of

rang

e 2%

of

rang

e 1%

with

10

cou

nts)

5 co

unts

)5

coun

ts)

10 c

ount

s)w

ith fl

ex C

Tw

ith fl

ex C

Tw

ith fl

ex C

Tfle

x CT

Pow

er Q

uali

ty S

elec

tion

Gui

de

Chec

k th

e Fl

uke

Web

for

det

aile

d sp

ecifi

catio

ns

Page 60: Fluke 2007

58

Fluke 345 Power Quality Clamp Meter

TLK291See page 89

TP220See page 89

AC220See page 89

TP1 See page 89

C550See page 94

The ideal troubleshooting tool for modernelectrical loads

The Fluke 345 measures a wide range ofelectrical parameters for troubleshootingpower disturbances in single- and three-phase electrical loads. With a bright colordisplay to see waveforms and trends, alow-pass filter to remove high frequencynoise, and a high EMC immunity design,the Fluke 345 is ideal for measurements onswitching loads such as variable speeddrives, electronic lighting and UPS systems.

• High safety rating: 600V CAT IV / 1000VCAT III rated for use at the serviceentrance

• ac/dc current measurements: Clamp-onmeasurement of ac peak and dc currentup to 2000 A without breaking the circuit

• Harmonic analysis: Analyze, display andlog harmonics up to the 30th harmonic(40th harmonic for 15 Hz to 22 Hz)

• Verify batteries: Direct measurement ofdc ripple (%) for battery and dc systems

Recommended Accessories

Power supply: 1.5 V Alkaline AA MN 1500 orIEC LR6 x 6 BatteryBattery life (typical): >10 hours (backlight onfull); >12 hours (backlight reduced)Safety: IEC 61010-1 600 V CAT IV, 1000V CAT III(maximum input phase-phase 825V rms) doubleor reinforced insulation, pollution degree 2Protection: IP40; EN60529Operating temperature: 0 °C to 50 °C

Display: Color transmissive LCD 320 x 240 pixels(70 mm diagonal) with 2 level backlightDigital output: USB interface to a PCSize (HxWxD): 300 mm x 98 mm x 52 mmJaw opening: 60 mmJaw capacity: 58 mm diameterWeight (including batteries): 0.82 kgTwo Year Warranty

Specifications

(Check the Fluke web for detailed specifications)

Current measurement

DC, DC rms, AC rms All measurements dc and 15 Hz to 1 kHz.Maximum overload 10,000 A or RMS x frequency < 400,000. Amps rms is a true rmsmeasurement (ac + dc).

Measuring range 0 – 2000 A dc or 1400 ac rms

Harmonics All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz); Frequencyrange F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Iacrms > 10A

Voltage measurement

DC, DC rms, AC rms All measurements dc and 15 Hz to 1 kHz. Maximum overload 1,000 V rms. Volts rms isa true-rms measurement (AC + DC).

Measuring range 0 – 825 V dc or ac rms

Harmonics All measurements up to 30th harmonic; Frequency range F0 : 15 Hz to 22 Hz and 45 Hzto 65 Hz; Vacrms > 1V

Watts measurement (single- and three-phase) DC, DC rms, AC rms

Measuring range 0 – 1650 kW dc or 1200 kW ac

VA measurement (single- and three-phase) DC, DC rms, AC rms

Measuring range 0 -1650 kVA dc or 1200 kVA ac

VAR measurement (single- and three-phase)

Measuring range 0 – 1250 kVAR

Power factor (single- and three-phase)

Measuring range 0.3 cap…1.0… 0.3 ind (72.5° cap…0°… 72.5° ind)

Displacement power factor

Measuring range 0.3 cap … 1.0 … 0.3 ind (72.5° cap ... 0° ... 72.5° ind)

Kilowatt Hour (kWHr)

Measuring range 40,000 kWHr

Scope function

Time base 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div

Current management:

Ranges 10 A/20 A/40 A/100 A; 200 A/400 A/1000 A/2000 A

Voltage measurement:

Ranges 4 V/10 V/20 V/40 V/100 V; 200 V/400 V/1000 V

Inrush current function All measurements dc and 15 Hz to 1 kHz

Ranges 40, 400 and 2000 A

Memory Up to 50 screen shots and over 150,000 individual measurement values

Included AccessoriesSoft carrying case, Power Log software, Test probes, Test leads, Alligator clips,International ac adapter / battery eliminator,Printed English User manual, Multi-languagemanual on CD

Ordering InformationFluke 345 Power Quality Clamp Meter

View waveforms for equipmentchecking and setup

Fluke 345

Log parameters over time to track down intermittent faults

Page 61: Fluke 2007

59

43B Single-phase PowerQuality Analyzer

C789 (43 Basic)See page 94

i2000flexSee page 90

i1000sSee page 90

80TKSee page 92

PAC91See page 71

The perfect tool for tracking down single-phase power-related problems

The Fluke 43B is the choice for diagnosingand troubleshooting power quality andgeneral equipment failures. Ease to usethanks to menu selection of the power

modes, it combines the capabilities of apower quality analyzer, a 20 MHzoscilloscope, a multimeter and a datarecorder in a single instrument.

Included (replacement)AccessoriesFluke 43Basic, Fluke43B and Fluke43Kit:TL24 (TL224) test lead set, AC20 (AC220)alligator clip set, TP4 test probe set, BP120MHrechargeable battery pack, BB120 ShieldedBNC adapter, PM8907 line adapter/charger,user and application manual. Fluke43Basic: i400s AC current clamp.Fluke43B and Fluke 43Kit: i400s AC currentclamp, AB200 alligator clip set, TP1 testprobe set, C120 hard carrying case, OC4USBinterface cable, SW43W FlukeView Software. Fluke 43B: VPS 40 voltage probe, Fluke 61 IRthermometerFluke43 Kit: VR101S voltage event recorder.

Ordering InformationFluke 43Basic Power Quality Analyzer

(single-phase)Fluke 43B Power Quality Analyzer

(single-phase)Fluke 43Kit Power Quality Analyzer

(single-phase)

Menu items Measurements Ranges AccuracyVolts/Amps/Hz Volts 5.000 V-1250 V ±(1%+10)

Amps 50.00A-50.00 kA ± (1%+10)Mains frequency 40.0 - 70.0 Hz ± (0.5%+2)CF Crest Factor 1.0 to 10.0 ± (5%+1)

Power Watts, VAR, VA 250 W-1.56 GW ± (4%+4)PF, DPF, COS ϕ 0.25-0.9 ± 0.04

0.90-1.00 ± 0.03

Harmonics Volts 1st to 51st harmonic ± (3%+2) to ± (15%+5)Amps 1st to 51st ± (3%+8) to ± (15%+5)Watts 1st to 51st ± (5%+2) to ± (30%+5)K-factor 1.0 to 30.0 ± 10%

Sags & Swells Voltage and Current 4 min-16 days selectable ± (2%+10)

Transient Capture 40 ns pulse width Select 20/50/100/200% ± 5% of full scaleUp to 40 transients above or below line voltage

Inrush Current 1sec. to 5 min selectable 1 A to 1000 A ± 5% of full scale

Ohms/Continuity/ Ohms 500.0 to 30.00 M ± (0.6%+5)Capacitance Capacitance 50.00 nF to 500.0 µF ± (2%+10)

Temperature °C -100.0°C to 400.0°C ± (0.5%+5)(with accessory) °F -200.0°F to 800.0°F

Scope DC, AC, AC+DC, peak, Sampling rate: 25 MS/secpeak-peak, Hz, duty cycle, Bandwidth: phase, pulse width, Voltage BW (Channel 1) 20 MHzcrest factor Current BW (Channel 2) 15 kHz

Screen saves All functions 20 screens

Recording V/A/Hz, Power, Harmonics, 4 min – 16 days selectable Select any two parameters /Cap, Temperature, Scope display mode in each

True RMS

Recommended Accessories

Battery life: Rechargeable Ni-MH pack (charger included), 6 hrs typical (continuous)Shock & Vibration: Mil 28800E, Type 3, Class III, Style B.Operating temperature: 0°C to 50°C; Case: IP51 (dust, drip, waterproof)Size (HxWxD): 232 mm x 115 mm x 50 mm; Weight: 1.1 kgThree Years Warranty

On all inputs

• Watts, power factor, COS ϕ, VA and VAR• Voltage and current waveforms

• Voltage, current, and power harmonics• Up to 51st harmonic• Total harmonic distortion (THD)• Phase angle of individual harmonics

• Continuously measure volts and amps on a cycle-by-cyclebasis for up to 16 days

• Use cursors to read time and date of sags and swells

• Connect-and-View™ scope for quick waveform display• View voltage and current channels simultaneously

Specifications

(Check the Fluke web for detailed specifications)

Fluke 43B

Page 62: Fluke 2007

430 Series Three-phase Power Quality Analyzers

60

NewPinpoint power quality problems faster, saferand in greater detail

The Fluke 435 and 434 three-phase powerquality analyzers help you locate, predict,prevent and troubleshoot problems in powerdistribution systems. These easy-to-usehandheld tools have many innovativefeatures to give you the details to pinpointproblems faster and safer.

• Complete three-phase troubleshooting tool:measures virtually every power systemparameter: voltage, current, frequency,power, power consumption (energy),unbalance and flicker, harmonics andinter-harmonics. Captures events likedips and swells, transients, interruptionsand rapid voltage changes.

• The Fluke 435 features 0.1 percentvoltage accuracy making it fullycompliant with the IEC 61000-4-30 Class A standard

• Logger: record the detail you need.Detailed, user-configurable long-timerecording gives you the MIN, MAX andAVG readings of up to 100 parameters onall 4 phases with selectable averagingtime down to 0.5 seconds. Enoughmemory is available to record 400 parameters with 1 minute resolutionfor up to a month.

• Four channels: simultaneously measuresvoltage and current on all three phasesand neutral.

• AutoScaling: easier trend analysis withautomatic scaling of the vertical axis youwill always use the full display to viewthe waveforms.

• Automatic transient display: captures upto 40 dips, swells, interruptions ortransients automatically.

• Meets the stringent 600 V CAT IV, 1000 VCAT III safety standard required formeasurements at the service entrance.

• Rugged, handheld instrument operatesfor more than 7 hours on includedrechargeable NiMH battery pack. Menu-driven interface simplifies operation.

• Extensive data analysis possibilities.Cursors and zoom can be used ‘live’ whiletaking the measurements, or ‘offline’ onstored measurement data. The storedmeasurements can also be transferred toa PC with FlukeView software (includedwith Fluke 435 and 434).

• The Fluke 435 comes with Power Logsoftware to analyse recorded data and tocreate reports.

• Complete package includes everything toget started: 4 current clamps, 4 flexclamps with Fluke 435, 5 voltage testleads and clips, line adapter/batterycharger and hard case.

• Complies with IEC 61000-4-30measurement standards.

AutoTrend - Quickly see the trendUnique AutoTrend gives you fast insight intochanges over time. Every displayed readingis automatically and continuously recordedwithout having to set up threshold levels orinterval times, or having to manually startthe process. You can quickly view trends involtage, current, frequency, power,harmonics or flicker on all three phases plusneutral. And you can analyze the trendsusing the cursors and zoom function – evenwhile background recording continues.

SystemMonitor - Check performanceagainst EN50160 with easeWith a single push of a button, the uniqueSystem-Monitor gives you an overview ofpower system performance, and checks thecompliance of incoming power to EN50160limits or to your own custom specifications.The overview is shown on a single screen,with color-coded bars clearly indicatingwhich parameters fall outside the limits.

True RMS

On all inputs

Fluke 434

AutoTrend automatically records all displayedparameters in the background.

The System-Monitor overview screen givesinstant insight into whether the voltage,harmonics, flicker, frequency and the numberof dips and swells fall outside the set limits.A detailed list is given of all events fallingoutside the set limits.

Fluke 435

Page 63: Fluke 2007

61

430 Series Three-phase Power Quality Analyzers

Recommended Accessories

i430-flex-4pk i5sPQ3See page 91

i1000sSee page 90

OC4USBSee page 71

Included AccessoriesHard carrying case C430 (434)/ Water-tighthard case with rollers C435 (435)4 current clamps, i400s, CAT IV 600 V4 current clamps, i430-Flex-4pk, CAT IV600 V (435)5 Test leads, 4black, 1 greenBattery Charger Eliminator, BC430FlukeView Software, SW43WPower Log Software (435)Optical Cable for USB , OC4USBColor localization set, WC100Getting Started printedUser Manual (CD-ROM)

Ordering informationFluke 435 Power Quality Analyzer

(three-phase) with Logger Function

Fluke 434 Power Quality Analyzer(three-phase)

Fluke 434/LOG Logger Upgrade Kit: Addsthe Logger Function of the435 to the 434

OC4USB Serial InterfaceAdapter/Cable (USB)

I5SPQ3 Set of 3, 5A AC current clamp

I430-flex-4pk Set of 4, 3000 Aflexclamps

PM9080 Serial InterfaceAdapter/Cable (RS232)

GPS430 GPS sync modulefor 430 Series

Measure and record power (W), VA and VARs.The 434 adds the ability to record energyconsumption.

Track harmonics up to the 50th, and measureand record THD in accordance with IEC61000-4-7 requirements

Logging function allows you to customizemeasurement selections and providesinstantaneous analysis of user-selectableparameters.

Fluke 435 with flex clamps

Inputs Number of inputs 4 voltage and current (3 phases + neutral)Maximum input voltage 1000 Vrms (6kV Peak)Maximum sampling speed 200 kS/s on each channel simultaneously

Measurement range AccuracyVolt/Amps/Hertz Vrms (AC+DC) 1…1000 V ± 0.1% of nominal voltage

Vpk 1…1400 V 5% of VnomCrest factor, voltage 1.0 ... > 2.8 ± 5%Arms (AC+DC) 0…20,000 A ± 0.5% ± 5 countsApeak 0 - 5500 A 5%Crest factor, A 1 … 10 ± 5%Hz 50Hz nominal 42.50 ... 57.50 Hz ± 0.01Hz

Dips and swells Vrms (AC+DC) 2 0.0% ….100% of Vnom ± 0.2% of nominal voltageArms (AC+DC) 2 0 … 20,000 A1 ± 1% ± 5 counts

Harmonics Harmonic (interharmonic) (n) DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7Vrms 0.0 … 1000 V ± 0.05% of nominal voltageArms 0.0 … 4000 mV x clamp scaling ± 5% ± 5 countsWatts depends clamp scaling and voltage ± 5% ± n x 2% or reading,

± 10 countsDC voltage 0.0 … 1000 V ± 0.2% of nominal voltageTHD 0.0 … 100.0 % ± 2.5% V and A (± 5% Watt)Hz 0 … 3500 Hz ± 1 HzPhase angle -360º ... +360º ± n x 1.5º

Power and Energy Watt, VA, VAR 1.0 … 20.00 MVA1 ± 1% ± countskWh, kVAh, kVARh 00.00 …200.0 GVAh1 ± 1.5% ± 10 countsPower Factor/ Cos ϕ / DPF 0…1 ± 0.03

Flicker Pst (1min), Pst, Plt, PF5 0.00 … 20.00 ±5%Unbalance Volts 0.0 … 5.0% ± 0.5%

Current 0.0 … 20% ± 1%Transient capture Volts ± 6000 V ± 2.5% of Vrms

Minimum detect duration 5 µs (200 kS/s sampling)Inrush mode Arms (AC+DC) 0.000 … 20.00 kA1 ± 1% of meas ± 5 counts

Inrush duration (selectable) 7.5 s … 30 min ± 20 ms (Fnom = 50 Hz)AutoTrend recording Sampling 5 readings/sec continous sampling per channel

Memory 1800 min, max and avg points for each readingRecording time Up to 450 daysZoom Up to 12x horizontal zoom

Memory Screens & data 50, shared memory divided between logging, screens and data sets

Standards Measurement methods used IEC61000-4-30 class A; EN50160; IEC 61000-4-15; IEC 61000-4-7

Battery life: > 7 hours with rechargeable NiMH (installed); Battery charging time: 4 hours typicalSafety: EN61010-1 (2nd edition) pollution degree 2; 1000 V CAT III / 600 V CAT IVCase: Rugged, shock proof with integrated protective holster, IP51 (drip and dust proof)Shock: 30 g; Vibration: 3g according to MIL-PRF-28800F Class 2Operating temperature: 0°C to +50°CSize (HxWxD): 256 mm x 169 mm x 64 mm; Weight: 1.1 kgThree Years Warranty

1 depending clamp scaling2 Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle

Specifications

(Check the Fluke web for detailed specifications)

Page 64: Fluke 2007

VR 101S Voltage EventRecorder System

62

Included AccessoriesVR101S: Optical interface cable

EventView Software

Ordering InformationFluke VR101S Voltage Event Recorder

SystemFluke VR101 Voltage Event Recorder(Note: At least one VR101S is required forproper operation.)

Electrical (voltage versions, plug style, and manual languages are determined by countryVoltage version Operating range Nominal frequencies Power consumption120V Version 70V to 140V 50 Hz to 60 Hz 2W230V Version 140V to 270V 50 Hz to 60 Hz 3WSags, Swells & Outage MeasurementsVoltage version Range Accuracy Resolution120V Version Hot-to-neutral 0 to 200 Vrms ± 2 Vrms 1 Vrms120V Version Neutral-to-ground 3 to 200 Vrms ± 2 Vrms 1 Vrms230V Version Hot-to-neutral 0 to 400 Vrms ± 4 Vrms 2 Vrms230V Version Neutral-to-ground 3 to 150 Vrms ± 2 Vrms 1 VrmsTransient Measurements, Minimum pulse width: 1µs

Range Accuracy ResolutionHot-to-neutral 100 to 2500 Vpeak ± (10% reading + 10V) 10VNeutral-to-ground 50 to 2500 Vpeak ± (10% reading + 10V) 10VPhase angle 20° to 180° ± 1° 1°

200° to 360°Time Measurements: Events < 1 second

Accuracy ResolutionHot-to-neutral ± 0.5 cycles 0.5 cyclesNeutral-to-ground ± 1 cycle 1 cycleFrequency Measurement:

Range Resolution45...65Hz 0.1 Hz

Events 1 second (time stamp)Accuracy Resolution± (2 sec/day + 8 sec) 8 sec

EnvironmentalOperating temperature -40 to 70° CRelative humidity 0 to 95% (non-condensing)Computer Hardware RequirementsIBM PC or 100% compatible, with Windows 3.1 or Windows 95/98/NT/XP or 2000 installed and operating. At least one free RS-232 serial port. A pointing device (recommended). 2 MB hard drive space. 4 MB RAM (8 MB for Windows 95/98 or higher).

Set up, plug in, download, and analyze

The Fluke VR101S is the perfect system forcatching sags, swells, transients, outagesand frequency variations on line voltage atreceptacles, where the most sensitive loadsare connected. The VR101S is a startersystem that includes a compact VR101 eventrecorder, an optical interface cable, andEventView™ software that turns your PCinto a power quality reporting tool.Additional VR101 event recorders can bepurchased individually, so you can monitorseveral voltage conditions at multiplelocations at once. To set up a VR101 event recorder, just enterthe event capture limit parameters on yourPC and load them into the recorder.EventView software and the optical interfacecable make it easy. Then plug the recorder

into the outlet you need to test, and leaveit—there’s no need to leave a computerhooked up. The compact recorder stores any voltageevent that goes outside your limits. The VR101 recorder can store up to as manyas 4000 events and a flashing LED tellsyou when events have been captured. To get data out of the recorder, hook it backup to your computer. EventView softwarecan download a complete history of theevents that occurred while the recorder wasplugged into the receptacle. The softwarelets you build a detailed report of sags,swells, transients, outages and frequencyvariations with time-stamps and durations.

True RMS

On all inputs

Memory size: 4000 eventsBattery type: 3.5 Lithium (non-replaceable)Battery life: 7 yearsSize (HxWxD): 62 mm x 68 mm x 85 mm

Weight: 0.12 kgOne Year Warranty

Specifications

(Check the Fluke web for detailed specifications)

Page 65: Fluke 2007

63

1735 Power Logger

Included AccessoriesSoft carrying case, 4 flexible current probes(15 A/150 A/3000 A), Power Log software,Voltage leads and clips, Color localization set,PC interface cable, International ac adapter(115/230 V, 50/60 Hz), Printed Englishmanual, and Multi-language manual CD.

Ordering InformationFluke1735 Power Logger

Performs electrical load studies, energyconsumption testing, and general powerquality loggingThe Fluke 1735 Power Logger is the idealtool for electricians and maintenancetechnicians for conducting energy studiesand basic power quality logging. The 1735is easy to set up with its color display andfour included flexible current probes. The 1735 logs most electrical powerparameters, harmonics and capturesvoltage events. View graphs and generatereports with the included Fluke Power Logsoftware.

• Record power and associated parametersfor up to 45 days

• Monitor maximum power demand overuser-defined averaging periods

• Prove the benefit of efficiencyimprovements with energy consumptiontests

• Measure harmonic distortion caused byelectronic loads

• Improve reliability by capturing voltagedips and swells from load switching

• Confirm instrument setup easily withcolor display of waveforms and trends

Volts rms V-rms wye measurement ranges:57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380V/400 V/417 V/480 V acV-rms delta measurement ranges:100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660V/690 V/720 V/830 V ac

Amps rms Flexi set measurement range: 15 A/150 A/3000 A rms (at sine)Current clamp measurement range: 1 A/10 A

Frequency Measurement range: 46 Hz to 54 Hz and 56 Hz to 64 Hz

Harmonics and THD To 50th harmonic (< 50 % of nom)

Power measurement Measuring range: see V-rms and A-rms measurement ranges(P - Active, S - Apparent, Q - Reactive, D - Distorting)

Energy Measurement (kWh, KVAh, kVARh) Measuring range: see V-rms and A-rms measurement ranges

PF (Power factor) 0.000 to 1.000

Events Detection of voltage dips, voltage swells and voltage interruptions with a 10 msresolution and measuring error of the half period sine wave of rms.

General

Memory 4 MB Flash memory, 3.5 MB for measuring data

Sample rate 10.24 kHz

Line frequency 50 Hz or 60 Hz, user-selectable, with automatic synchronization

Model Description

• MBX Clamp 1 A/10 A 3 precision dual range current clamps (1 A/10 A) for secondary CT applications

Recommended Accessories

Fluke 1735

Specifications

(Check the Fluke web for detailed specifications)

Display: VGA Graphic Color transmissive displays 320 x240 pixels with additional background lighting andadjustable contrast, text and graphics in colorInterface: RS-232 SUB-D socket; 115.2 k Baud,8 data bits, no parity, 1 stop bit, firmware updates arepossible with the RS-232 interface (9-pole extension cable)Housing: IP65; EN60529 (refers only to the mainhousing without the battery compartment)

Power supply: NiMH battery-pack, with ac adapter (15 Vto 20 V/0.8 A)Battery Life: Typical > 12 hours without backlight and> 6 hours with backlight highOperating temperature: 0°C to +40°CSize (HxWxD): 240 mm x 180 mm x 110 mmWeight: 1.7 kg, including batteryTwo Year Warranty

Conduct loadstudies for up to45 days and viewsaved dataon-screen or ona computer.

Quantify energyconsumptionquickly on-screenor log to memoryfor extendedperiods.

Access voltage andcurrent harmonicsup to the 50th.

Capture voltageevents using user-defined thresholds.

View recorded data in simplegraphs and tables with Fluke PowerLog software.

Customize the report generator toeasily generate professional lookingreports.

Page 66: Fluke 2007

1740 Series Three-PhasePower Quality Loggers Memobox

64

Included Accessories4 Flexible probes 15/150/1500/3000 A with 2 m cable, CD-ROM with PQ Log software,RS232 interface cable and RS232-USBadapter, 4 black dolphin clips, Test leads forvoltages and power supply, Color localizationkit, Carrying bag, Test certificate withmeasurement values, Printed English manual,and Multi-language manual CD.

Ordering InformationFluke 1743 Power Quality Logger MemoboxFluke 1744 Power Quality Logger MemoboxFluke 1745 Power Quality Logger Memobox

Assess power quality and conduct long-termstudies with ease Compact, rugged and reliable, the Fluke1740 Series three-phase power qualityloggers are everyday instruments fortechnicians who troubleshoot and analyzepower distribution systems. Capable ofsimultaneously logging up to 500parameters for up to 85 days and capturingevents, the Fluke 1740 Series helps uncoverintermittent and hard-to-find power qualityissues. There are three models to choosefrom to meet your basic or advanced powerlogging needs.

Fluke 1743: IP65 water-proof monitor forlogging the most common powerparameters including V, A, W, VA, VAR, PF,energy, flicker, voltage events, and THD.

Fluke 1744: Includes the same features asthe Fluke 1743. In addition to commonpower parameters, the Fluke 1744 alsomeasures voltage and current harmonics,interharmonics, mains signaling,unbalance, and frequency.

Fluke 1745: Advanced IP50 power qualitylogger with the same measurementcapability as the 1744, plus real-time LCD,five hour UPS.

• Plug and play: Setup in minutes withautomatic current probe detection andpowering

• Installs inside the cabinet: Compact,fully-insulated housing and accessories fiteasily in tight spaces next to live power

• Monitors power for the long-term: Datacan be downloaded during recordingwithout interruption

• Measure voltage with premiumaccuracy: IEC61000-4-30 Class-Acompliant voltage accuracy (0.1%)

• Quickly validate quality of power:Assess power quality according toEN50160 power quality standard withstatistical overview

Measurement of common power parameters: V, A, W, VA,VAR, PF, energy, flicker, voltage events (dips, swells,interruptions), and THD

Measurement of voltage and current harmonics to the50th, unbalance, frequency and mains signaling

Dust/water resistance

Display

Memory

UPS ride-through

EN 50160

1745 1744 1743

• • •

• •IP 50 IP 65 water proof

LED + LCD LED LED

8 MB 8 MB 8 MB

> 5 hrs 3s 3s

• • •

Model Description

• MBX CLAMP 1 A / 10 A 3-phase current clamps with 2 ranges 1 A/10 A, 2 m cable

• MBX CLAMP 5 A / 50 A + N 3-phase+N current clamps with 2 ranges 5 A/50 A, 2m cable

• MBX CLAMP 20 A / 200 A + N 3-phase+N current clamps with 2 ranges 20 A/200 A, 2 m cable

• MBX 300 POLESET Pole mounting kit

Recommended Accessories

Specifications

(Check the Fluke web for detailed specifications)

Power supply: 88 V … 660 V acSafety: IEC/EN 61010-1 600 V CAT III, 300 V CAT IV,

pollution degree 2, double insulationHousing: Fully insulated housing and accessoriesOperating temperature: 0 °C to 35°CInterface: RS 232, 9600 ... 115 000 Baud, automatic

Baud rate selection, 3-wire communication

Size: Fluke 1745: 282 mm x 216 mm x 74 mm;Fluke 1743/44: 170 mm x 125 mm x 55 mm

Weight: Fluke 1745 – approx. 3 kg;Fluke 1743/44: approx. 2 kg

Two Year Warranty

The included PQ Log softwarehelps you to quickly identify theroot cause of a disturbance.

Fluke 1744

Fluke 1743

Fluke 1745

Page 67: Fluke 2007

65

1760 Three-Phase Power Quality Recorder Topas

Included Accessories2 GB internal Flash-memory, PC software on CD-ROM, 1 Ethernet cable for networkconnection, 1 crosslink Ethernet cable fordirect PC connection, 1 mains cable, hardwareand software manual, 1 carrying bag.

Ordering InformationFluke 1760 Basic Power Quality Recorder TopasFluke 1760TR Basic Power Quality Recorder TopasFluke 1760 Power Quality Recorder TopasFluke 1760TR Power Quality Recorder Topas

Class-A compliance for the most demandingpower quality testsThe Fluke 1760 Three-Phase Power QualityRecorder is fully compliant to IEC 61000-4-30 Class-A, for advanced power qualityanalysis and consistent compliance testing.Designed for analysis of utility andindustrial power distribution systems, inmedium and low-voltage networks, theFluke 1760 provides the flexibility tocustomize thresholds, algorithms, andmeasurement selections. It has 8 inputchannels (4 currents/4 voltages or 8voltages), and captures the mostcomprehensive details on user selectableparameters.

• GPS time synchronization: Correlatedata with events or datasets from otherinstruments with precision

• Uninterrupted power supply (40minutes): Never miss important events -even record the beginning and end ofinterruptions and outages

• 10 MHz, 6000 Vpk waveform capture:Get a detailed picture of even theshortest event

• 2 GB data memory: Enables detailed,simultaneous recording of numerouspower parameters for long periods oftime

• Includes Comprehensive software:Provides trend diagrams for root causeanalysis, statistical summaries, reportwriting and real-time data monitoring inthe online mode

Power quality statistics according to EN50160

Voltage event list (dips, swells and interruptions)

Continuous recording of:

Voltage

Current

Power P, Q, S

Power factor

kWh

Flicker

Unbalance

Frequency

Voltage and current harmonics to the 50th/Interharmonics

THD

Mains signaling

Triggered recordings

Online mode (Oscilloscope, transients and events)

Fast transient analysis up to 10 MHz

4 voltage probes

4 dual-range flexible current probes (1000 A / 200 A ac)

GPS time sync receiver

Memory

1760 Basic 1760TR Basic 1760 1760TR

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• • • •

• •

• •

• •

• •

2 GB Flash memory

Model Description

• TPS VOLTPROBE 10 V 10 V Voltage Probes (Range: 0.1 V to 17 V)

• TPS VOLTPROBE 100 V 100 V Voltage Probes (Range: 1 V to 170 V)

• TPS VOLTPROBE 400 V 400 V Voltage Probes (Range: 4 V to 680 V)

• TPS VOLTPROBE 750 V 400 V / 750 V Peak Voltage Probes (Range: 4 V to 680 V)

• TPS VOLTPROBE 600 V 600 V Voltage Probes (Range: 10 V to 1000 V)

• TPS VOLTPROBE 1 KV 1000 V Voltage Probes (Range: 10 V to 1700 V)

• TPS FLEX 18 Flexible Current Probe (Range: 1 A to 100 A / 5 A to 500 A)

• TPS FLEX 24 Flexible Current Probe (Range: 2 A to 200 A / 10 A to 1000 A)

• TPS FLEX 36 Flexible Current Probe (Range: 30 A to 3000 A / 60 A to 6000 A)

• TPS CLAMP 10 A / 1 A Clip-on Current Transformer (Range: 0.01 A to 1 A / 0.1 A to 10 A)

• TPS CLAMP 50 A / 5A Clip-on Current Transformer (Range: 0.05 A to 5 A / 0.5 A to 50 A)

• TPS CLAMP 200 A / 20 A Clip-on Current Transformer (Range: 0.2 A to 20 A / 2 A to 200 A)

• TPS SHUNT 20 MA 20 mA ac/dc Shunt (Range: 0 to 55 mA)

• TPS SHUNT 5 A 5 A ac/dc Shunt (Range: 0 to 10 A)

Recommended Accessories

Specifications

(Check the Fluke web for detailed specifications)

Power supply: : 83 V to 264 V, 45 to 65 HzBattery pack: NIMH, 7.2 V, 2.7 Ah (up to 40 minutes

back-up power supply)Safety: 600V CAT IV/1000V CAT III

(Rated for use at the service entrance)Housing: Fully insulated robust plastic housing

Operating temperature: 0 °C to 35°CInterfaces: Ethernet (100 MB/s), RS-232, external

modem via RS-232Size (H x W x D): 325 mm x 300 mm x 65 mmWeight: Approxiamtely 4.9 kgTwo Year Warranty

The included PQ Analyze softwareprovides a detailed overview ofseveral power quality parameterson one dashboard according tothe EN50160 power qualitystandard.

Fluke 1760

Page 68: Fluke 2007

ScopeMeter® Test Tools

With the original ScopeMeter, we transformed the oscilloscope categorybeyond recognition, and we still lead the way today. From ruggedsolutions for industrial applications to full-colour models that pack top-end bench oscilloscope specifications into hand-held, battery poweredinstruments. In short, ScopeMeter provides you with unmatched speed,performance and analysis power while working on site.

66

Page 69: Fluke 2007

ScopeMeter® Test Tools

Oscilloscopes for field applications

67

199C 196C 199B 196B 192B 124 123Oscilloscope SpecificationsBandwidth 200 MHz 100 MHz 200 MHz 100 MHz 60 MHz 40 MHz 20 MHzMaximum real time sample rate 2.5 GS/s 1 GS/s 2.5 GS/s 1 GS/s 500 MS/s 25 MS/s

Input sensitivity 2 mV to 100 V/div 5 mV to 100 V/div 5 mV-500 V/divTimebase range 5 ns/div to 2 min/div 10 ns/div to 10 ns/div to 20 ns/div to

2 min/div 1 min/div 1 min/divInputs and digitizers 2 plus external trigger/DMM input 2Independently floating isolated Up to 1000 V between inputs,inputs references and groundMax. record length… in Scope mode: 3.000 points per input 512 min/max … in ScopeRecord mode: 27.500 points per input or more (5 ms/div…2 min/div.) points per input

Glitch capture Up to 3 ns using Pulse Width triggering; 50 ns peak 40 nsecdetect at 5 µs/div. to 1 min/div.

Scope measurements 7 cursor+30 automatic cursors + 26 automatic 26 automatic

True RMS multimeter 5000 counts, single input 5000 counts, dual inputGeneral SpecificationsLine Power Adapter/Battery charger includedBattery power 4 hours NiMH 7 hours NiMH 5 hours NiCadSize 256 x 169 x 64 mm 232 x 115 x 50 mmWeight 2 kg 1.2 kg Safety certified (EN61010-1) 1000 V CAT II/600 V CAT III 600 V CAT IIIWarranty 3 years 3 years

199C 196C 199B 196B 192B 124 123

-/ -/ -/ -/ -/ / /

1) 1) 1) 1) 1) 1) 1)

1) 1) 1) 1) 1) 1) 1)

Oscilloscope FeaturesLCD Display Color B/W B/WPersistence DigitalWaveform referenceAutomatic pass fail testingCursors and zoom CursorsConnect-and-View TriggeringVideo triggering with line countSelectable pulse width triggeringCapture and replay of last 100 screens

Dual Input TrendPlot With cursors and zoomMemory for screens and setups 10 screens and setups 20 10

Recorder memories, each can store 100 2 recorder memoriesscope screens, a ScopeRecord or a TrendPlot

1000V Independently floating isolated inputs

Meter measurements: VAC RMS, VAC+DC, VDC, Ohms, Continuity, Diode, Amps, Temp. (°C, °F)

Waveform mathematics: A + B, A – B, A x B,A versus B (X-Y-mode)Frequency Spectrum Analysis using FFT Capacitance and frequency measurements

Rugged, Dust and drip proof case.

PC and Printer Interface via optically isolated RS-232/USB cable

FlukeView® for Windows® Software (SW90W)

Standard equipped 1) Optional

Features

Specifications

(Check the Fluke web for detailed specifications)

The ScopeMeter 190 Series ofhigh-end performanceoscilloscopes have bandwidthof 60, 100 and 200 MHz andsample rates up to 2.5 GS/s.The 190C Series adds a high-resolution color display that hasa fast update rate, waveformpass/fail testing and a digitalpersistence mode – making theanalysis of complex anddynamic signals much easier.

For industrial electronic orelectro mechanicalapplications, the 120 SeriesIndustrial ScopeMeter, with a20 or 40 MHz bandwidth andConnect-and-View™ triggeringfor an instant, stable displaywill get the job done.

Check the Fluke web site for Technical Specifications andApplication Notes for the Fluke ScopeMeters

Page 70: Fluke 2007

ScopeMeter® 190 Series

68

Speed, performance and analysis power

For more demanding applications, theScopeMeter 190 Series high performanceoscilloscopes offer specifications usuallyfound on top-end bench instruments. With up to 200 MHz bandwidth, 2.5 GS/sreal-time sampling and a deep memory of 27 500 points per input they’re ideal forengineers who need the full capabilities ofa high performance oscilloscope in ahandheld, battery powered instrument.

• Dual input – 60, 100 or 200 MHz models• Up to 2.5 GS/s real time sampling per input• Choice between a high resolution Color or

Black and White display• NEW. See even more detail than before.

The Fluke ScopeMeter 190 family is nowtwice as fast with >100/second traceupdates rates.

• High waveform resolution of3000 datapoints per channel

• Digital Persistence for analyzing complexdynamic waveforms like on an analogscope (190C Series only)

• Fast display update rate for seeing dynamicbehavior instantaneously

• Connect&View™ automatic triggering, a full range of manual triggering modesplus external triggering.

• Automatic capture and replay of 100 screens

• 27 500 points per input record lengthusing ScopeRecord mode

• Up to 1000 V independently floatingisolated inputs

• Waveform reference for visual comparisonsand automatic pass/fail testing ofwaveforms (190C Series only)

• Vpwm function for motor drive and frequencyinverter applications.

• Waveform mathematics: Add, Subtractand Multiply

• Frequency Spectrum Analysis using FFT(190C)

• Cursors, zoom and real-time clock• 30 automatic waveform measurements• Four hours rechargeable Ni-MH battery

pack• Includes a 5000 count true-RMS

multimeter and a TrendPlot™ paperlessrecorder

ScopeMeter for medicalapplicationsThe ScopeMeter 190 Series is also availableoptimized for measurements on medicalimaging equipment and video displaysystems. For more information please visitthe Fluke web site.

Automatic capture and replay of 100 screensScope users know how frustrating it is tosee a one time anomaly flash by never tobe seen again. Not with the ScopeMeter190 Series! Now you can look back in timewith a touch of the replay button. In normaluse, the instrument continuously memorizesthe last 100 screens. Each time a newscreen is acquired, the oldest is discarded.At any moment you can “freeze” the last100 screens and scroll through picture-by-picture or replay as a ‘live’ animation.Cursors can be used for further analysis.You can even use the advanced triggercapabilities to capture up to 100 specificevents. Two sets of 100 captured screenswith individual time stamps can be storedfor later recall or download to a PC.

True RMS

On all inputs

Fluke 199C

Fluke 196B Fluke 192B

Fluke 196C Fluke 199B

Page 71: Fluke 2007

ScopeMeter® 190 Series

69

SCC190 C195See page 94

OC4USBSee page 71

i400sSee page 90

SCC198 See page 96

Recommended Accessories

Included AccessoriesBC190 Battery ChargerBP190 NiMH Battery PackVPS200-G + VPS200-R Voltage ProbeTL75 Hard Point Test Lead Setuser’s manual (CD-Rom)

Ordering InformationFluke 192B ScopeMeter

(60MHz, 500 MS/s)Fluke 196B ScopeMeter

(100 MHz, 1 GS/s))Fluke 199B ScopeMeter

(200 MHz, 2.5 Gs/s)Fluke 196C Color ScopeMeter

(100 MHz, 1 GS/s)Fluke 199C Color ScopeMeter

(200 MHz, 2.5 GS/s)Fluke 192B/S 192B + SCC 190 kit optionFluke 196B/S 196B + SCC 190 kit optionFluke 199B/S 199B + SCC 190 kit optionFluke 196C/S 196C + SCC 190 kit optionFluke 199C/S 199C + SCC 190 kit optionSCC190 FlukeView Software,

OC4USB cable, carrying case for Fluke 190B and190C Series

SW90W FlukeView Software

Frequency Spectrum shows an overview offrequencies contained in a signal.

Fluke ViewScreenPulse width fluctuations are clearly visibleusing Digital Persistence

See dynamic signal behavior instantaneously The Digital Persistence mode helps to findanomalies and to analyze complex dynamicsignals by showing the waveforms amplitudedistribution over time using multiple intensitylevels and user selectable decay time - it’sas if you’re looking at the display of ananalog, real time oscilloscope! A fast displayupdate rate reveals signal changesinstantaneously, useful for instance whenmaking adjustments to a system under test.

Frequency Spectrum Analysis 190CAll 190C Color ScopeMeters includeFrequency Spectrum Analysis on Fast FourierTransformation (FFT) analysis as a standardfeature.This makes it possible to identify the individualfrequency components contained in a signal.The spectrum analysis function is also handyto reveal the effects of vibration, signalinterference or crosstalk. An automaticwindow function assures optimal windowing,although you may manually select yourpreferred time window.

FlukeView® Software fordocumenting, archiving and analysisFlukeView® for Windows® helps you get moreout of your ScopeMeter by:• Documenting - transfer waveforms, screens

and measurement data from the ScopeMeterto a PC. Print or import the data into yourreport

• Archiving - create a library of waveformswith your comments for easy referenceand comparison

• Analysis - use cursors, perform spectrumanalysis or export data to other analysisprograms

Thanks to the deeper memory, very small parts of the waveform can bestudied in full detail using “zoom”.

See page 67 for specifications.

Page 72: Fluke 2007

SCC120 C43See page 94

DP120See page 71

OC4USB See page 71

SCC128 See page 96

Included AccessoriesPM 8907 line adapter/charger, STL120shielded test leads set, AC120 AlligatorClips, HC120 Hook Clips, BB120 shieldedBNC adapter, BP120MH NiMH, battery pack(Fluke 123), BP130 NiMH, battery pack(Fluke 124), VPS40 Voltage Probe (Fluke124), user’s manual (cd-rom)

Ordering InformationFluke 123 Industrial ScopeMeter® (20MHz)Fluke 123/S Industrial ScopeMeter® (20MHz)

including SCC120 kit optionFluke 124 Industrial ScopeMeter® (40MHz)Fluke 124/S Industrial ScopeMeter® (40MHz)

including SCC120 kit optionSCC120 FlukeView Software, OC4USB

Cable, Carrying Case Kit forFluke 120 series

SW90W FlukeView Software

True RMS

Recommended Accessories

On all inputs

ScopeMeter® 120 Series

70

Three-in-one simplicity

The compact ScopeMeter 120 Series is therugged solution for industrial troubleshootingand installation applications. It’s a trulyintegrated test tool, with oscilloscope,multimeter and “paperless” recorder in oneaffordable, easy-to-use instrument. Find fastanswers to problems in machinery,instrumentation, control and power systems.

• Dual-input 40 MHz or 20 MHz digitaloscilloscope

• Two 5,000 counts true-RMS digitalmultimeters

• A dual-input TrendPlot™ recorder• Connect-and-View™ trigger simplicity for

hands-off operation• Shielded test leads for oscilloscope,

resistance and continuity measurements• 10:1 Voltage Probe included with Fluke

124 for high frequency measurements• Up to 7 hours battery operation • 600 V CAT III safety certified • Optically isolated RS-232 interface• Rugged, compact case

Connect-and-View™ triggering foran instant, stable displayScope users know how difficult triggeringcan be. Wrong settings show unstable andsometimes wrong results. Fluke’s uniqueConnect-and-View recognizes signalpatterns, and automatically sets up correcttriggering. It provides a stable, reliable andrepeatable display of virtually any signal -

including motordrive and control signals -without touching a button. Signal changesare instantly recognized and settingsadjusted for - once again - a stable display.Benefit from the speed and conveniencewhen measuring a number of testpoints inquick succession.

Use TrendPlot™ to help findintermittents fastThe toughest faults to find are those thathappen only once in a while: intermittents.They can be caused by bad connections,dust, dirt, corrosion or simply brokenwiring or connectors. You may not bearound to see it – your Fluke ScopeMeterwill. In this “paperless recorder” mode, you can plot the minimum and maximumpeak values and average over time – up to22 days (Fluke 190 Series) or 16 days(Fluke 120 Series). The two inputs can plotany combination of volts, amps, temperature,frequency and phase – with time and datastamp – to help lead you to the cause ofthe faults quickly.

Connect-and-View captures even the most complex motor drive signals

Cursors help you analyze the capturedTrendPlot

Fluke 123

Fluke 124

See page 67 for specifications.

Page 73: Fluke 2007

ScopeMeter® Accessories

71

PM9091/9092

RS200 AS200-R PM9090OC4USB PM9080

VPS100/200 seriesVPS40 DP120

VPS40 VPS200-R VPS200-G VPS201 VPS100-R VPS100 VPS250 VPS121 DP120 PM8918/301

Description Voltage Voltage Voltage Voltage Voltage Voltage Voltage Voltage Differential Low Pass

Probe Set Probe Set Probe Set Probe Set Probe Set Probe Set Probe Set Probe Probe Set Filter Probe

Number and Color One Black One Red One Gray Red & Gray One Red Red & Gray Red & Gray One Black Red & Gray One Blue

Attenuation 10:1 10:1 10:1 100:1 10:1 10:1 10:1 1:1 200:1, 20:1 10:1

Band Width DC-MHz 40 200 200 200 100 100 75 12 20 4 kHz

Length [m] 1.2 1.2 1.2 1.2 1.2 1.2 2.5 1.2 1.5 2.5

Safety. EN 61010-2 1000 1000 1000 1000 1000 1000 1000 - 1000 -

CAT II Voltage [V]

Safety. EN 61010-2 600 600 600 600 600 600 600 300 600 600

CAT III Voltage [V]

ScopeMeter 190 Series

ScopeMeter 120 Series 1)

Battery Packs

PM9086 NiCd Battery Pack for 90 Series

BP120MH NiMH Battery Pack for 120 Series + 43B

BP130 NiMH Battery Pack for Fluke 124 (and Fluke 123firmware V2)

BP190 NiMH Battery Pack for 190 + 430 Series

RS200 Probe Replacement Set for VPS200, VPS100, VPS40 Probes

AS200-R Probe Accessory Set, Red for VPS200, VPS100, VPS40 Probes

AS200-G Probe Accessory Set, Grey for VPS200, VPS100, VPS40 Probes

PM9080 Optical Interface Adapter Cable for serial port

OC4USB Optical Interface Adapter Cable for USB Port

PM9090 Probe Pin Grabber Flexible Clip for VPS200, VPS100, VPS40 Probes

PM9094 Mini Testhook Set for PM8918 Probes

PAC91 Printer Adapter Cable

PM9091 PM9092 PM9081 PM9082 PM9093

Description 50 BNC cable set 50 BNC cable set Dual Banana plug Dual Banana jack Male BNC to dual

(1Red, 1Gray, 1Black) (1Red, 1Gray, 1Black) male to female BNC male to female BNC female BNC

Length 1.5m 0.5m

CAT III Voltage [V] 300 300 300 300 300

ScopeMeter 190 Series

ScopeMeter 120 Series 1) 1) 1) 1)

All accessories have a one year warranty

PM9081 PM9082 PM9093

1) Using BB 120

Safety designed oscilloscope probes

Page 74: Fluke 2007

72

Field Calibrators

You’re responsible for testing and calibrating process controlinstrumentation. And you want your job done quickly and reliably.Count on the wide range of Fluke field calibration tools. You canmaintain and calibrate virtually all types of sensors and transmitters.Whether you want all the required functionality in just one tool or adedicated tool for temperature or pressure, or if you need intrinsicallysafe versions, the choice is yours.

72

Page 75: Fluke 2007

Field Calibrator Selection Guide

73

74

47

43

B7

41B

725

/72

5E

x7

26

72

471

471

271

8/7

18E

x71

771

57

07/7

07E

x77

17

05

78

97

87

300

V30

0 V

300

V30

V30

V30

V75

mV

10 V

28 V

28 V

1000

V10

00 V

300

V30

0 V

300

V10

00 V

1000

V11

k11

k11

k32

0040

0032

0032

0040

M40

M11

0 m

A11

0 m

A11

0 m

A24

mA

24 m

A24

mA

24 m

A24

mA

24 m

A24

mA

99.9

mA

24 m

A30

mA

, 1 A

30 m

A, 1

A

50 k

Hz

50 k

Hz

50 k

Hz

10 k

Hz

15 k

Hz

20 k

Hz

20 k

Hz

1

1

1

1

1

68,9

mba

rto

345

bar

2

88

87

87

711

1111

1212

129

15 V

15 V

15 V

10 V

20 V

10 V

75 m

V10

V11

k11

k11

k32

0040

0032

0032

0022

mA

22 m

A22

mA

24 m

A24

mA

24 m

A24

mA

24 m

A24

mA

24 m

A

50 k

Hz

50 k

Hz

50 k

Hz

10 k

Hz

15 k

Hz

88

87

87

711

1111

1010

109

/-

24 V

24 V

24 V

24 V

/12

V24

V24

V24

V/-

24 V

24 V

24 V

24 V

24 V

725E

x71

8Ex

707E

x

33

33/

13

33

33/

13

33/

13

33

374

7474

7575

7677

7778

7879

798

079

8181

Mod

elM

easu

reVo

ltage

DC

Volta

ge A

C (t

rue

RM

S)R

esis

tanc

eCu

rren

t D

CCu

rren

t A

CFr

eque

ncy

Pres

sure

Tem

pera

ture

: RT

D t

ypes

Tem

pera

ture

: TC

typ

esSo

urce

/Sim

ulat

eVo

ltage

DC

Res

ista

nce

mA

DC

/% s

cale

mA

sou

rce;

aut

o st

ep, a

uto

ram

pFr

eque

ncy

Tem

pera

ture

: RT

D t

ypes

Tem

pera

ture

: TC

typ

esR

ecor

dM

in/M

axH

old

As

Foun

d/A

s Le

ft r

esul

tsLo

g da

taU

ploa

d da

ta t

o PC

Rem

ote

oper

atio

nFe

atur

esLo

op s

uppl

yH

art

com

mun

icat

ion

Inte

grat

ed h

and

pres

sure

pum

pIn

trin

sica

lly s

afe

(ATE

X)N

IST

trac

eabl

e ce

rtifi

catio

nW

arra

nty

in y

ears

See

cata

log

page

1 Fl

uke

700

pres

sure

mod

ules

req

uire

d2

Ran

ges

for

the

inte

rnal

sen

sor.

Ran

ges

for

use

of F

luke

700

pre

ssur

e m

odul

es, s

ee p

age

82.

Doc

umen

tin

g Pr

oces

s C

alib

ator

sM

ulti

fun

ctio

nTe

mpe

ratu

re C

alib

rato

rsPr

essu

re C

alib

rato

rsLo

op C

alib

rato

rsPr

oces

sMet

ers

Proc

ess

Cal

ibra

tor

68,9

mba

r to

20

bar

/ 2

to 7

bar

2

Page 76: Fluke 2007

740 Series DocumentingProcess Calibrators

74

Included AccessoriesFluke 741B/743B: TL224 Industrial Test Leads(2 sets), AC220 Test Clips (2 sets), TP220 TestProbes (1 set), BP7217 Battery Pack, BC7217Battery Charger, Instruction Manual, NISTTraceable calibration certificate and data,three-year warranty, serial port cable (743Bonly), DPC/TRACK Sample Version with freePC communication utility software (743B only).Fluke 744: TL224 Industrial Test Leads (2 sets), AC220 Test Clips (2 sets), TP220 TestProbes (1 set), BP7235 NiMH Battery Pack,BC7217 Battery Charger, serial port cable,HART communications cable, DPC/TRACKSample Version with free PC communicationutility software, Instruction Manual, HART UsersManual, NIST Traceable calibration certificateand data.

Ordering InformationFluke 741B Documenting Process CalibratorFluke 743B Documenting Process CalibratorFluke 744 Documenting Process Calibrator700SW DPC/Track Software

0.05% 0.01%

0.3°C 0.2°C

0.3°C 0.1°C

C789See page 94

TL220See page 88

80PK-8See page 92

80PK-25See page 92

700P27See page 82

Calibrators as versatile as you are

The 740 series Documenting ProcessCalibrators are rugged, handheld tools for thecalibration and troubleshooting of processcontrol instrumentation. These calibrators:• Calibrate temperature, pressure, voltage,

current, resistance, and frequency• Simultaneously measure and source• Automatically capture calibration results• Document procedures and results to meet

ISO 9000, EPA, FDA, OSHA, and othergovernment requirements

• Measure/simulate eleven types ofthermocouples and eight RTDs

• Store up to 8,000 readings in data loggingmode (743B +744 only)

• Protected against dirt, dust, and moisture;unaffected by vibration

• PC interface (743B +744 only)• Operates in English, French, German,

Italian, and Spanish• One and two-year calibration cycles• Four types of built-in automated calibration

procedures; linear transmitter, square rootdevices, one and two-point limit switches

741B: A complete documentingcalibratorThe 741B is the economical choice for plantsthat don’t use PCs or that require traditionalpaper forms. It has storage capacity for aday’s calibration and measurement data.When you’re back at the shop, recall thedata on-screen to fill out calibration forms.

743B: More memory, plus a PCinterface and data loggingThe 743B has all the capabilities of the 741Bplus a PC interface that lets you downloadprocedures, lists, and instructions createdwith software–or upload data for printing,archiving, and analysis. With its expandedmemory, the 743B can hold a full week ofcalibrations and procedures.

744: Get HART-abilityThe Fluke 744 offers all of the capabilitiesof the 743B, plus the ability to calibrate,maintain, and troubleshoot HARTinstrumentation with just one tool. Thisrugged, reliable tool offers:• Integrated HART communication functions,

permitting you to monitor, control, andcalibrate HART instrumentation.

• NiMH battery with 3500 mA hour life andbattery indicator.

Instrumentation ManagementSoftwareThe Fluke 743B and 744 are compatiblewith Fluke 700SW DPC/TRACK softwareand with software from Cornerstone,Fisher-Rosemont, Honeywell, Yokogawa,Prime Technologies and On Time Support.

Recommended Accessories

Fluke 744

Fluke 743B

Fluke 741B

Function Measure Sourcing

Voltage DC 0.025% reading + 0.005% full scale 0.01% output + 0.005% full scale

Current DC 0.01% reading + 0.015% full scale 0.01% output + 0.015% full scale

Resistance 0.05% reading + 50m 0.01% output + 40m

Frequency

Thermocouples

RTDs

Pressure To 0.05% of full scale. See Pressure Module specifications.

Specifications

(Check the Fluke web for detailed specifications)

Operating temperature: -10º C to 50º C Safety: CAT II 300VBattery Life: Typically over eight hoursInternal Battery Pack: NiCd, 7.2V, 1700 mAh

Battery Replacement: Via snap-shut doorwithout opening calibrator; no tools requiredWeight: 1.4 kg Size (HxWxD): 236 mm x 130 mm x 61 mm Three Year Warranty

Page 77: Fluke 2007

725/725Ex/726 MultifunctionProcess Calibrators

75

Included AccessoriesTL75 Test Leads, AC72 Test Clips, one pairof stackable test leads, user’s Manuals onCD-ROM (725Ex also includes CCD controldrawing, Statement of Quality AssurancePractices, NIST Traceable calibrationcertificate)

Ordering InformationFluke 725 Multifunction Process CalibratorFluke 725Ex Intrinsically Safe Multifunction

Process CalibratorFluke 726 Precision Multifunction Process

CalibratorC125

See page 94TL220

See page 8880PK-27

See page 92TPAK

See page 97700P27

See page 82

More calibration power!

725/725Ex/726 Multifunction Process Calibrators • Two separate channels; measure, source

and view process signals simultaneously• Measure volts, mA, RTDs, thermocouples,

frequency, and resistance to test sensorsand transmitters

• Source/simulate volts, mA, thermocouples,RTDs, frequency, and pressure to calibratetransmitters

• Measure or *source pressure using any of29 Fluke 700Pxx Pressure Modules

• Source mA with simultaneous pressuremeasurement to conduct valve and I/Ptests

• Perform fast linearity tests with auto stepand auto ramp features

• Power transmitters during test using 24 Vloop supply and simultaneous mAmeasurement

• Store frequently-used test setups for later use

• For 725Ex version see also page 84 and 85

*Pressure pump required

726 Precision Multifunction Process CalibratorAdditional features:• More precise measurement and calibration

source performance, accuracies of 0.01%• Transmitter error% calculation• Memory storage for up to 8 calibration

results• Frequency totalizer and frequency pulse

train source mode for enhanced flowmetertesting

• HART mode inserts 250 ohm resistor inmA measure and source for compatibilitywith HART instrumentation

• Integrated pressure switch test allows youto capture the set, reset and deadband ofa switch

• Custom RTD curves, add calibrationconstants for certified RTD probes forenhanced temperature measurement

Function Range or Type Resolution Accuracy NotesMeasure or Source

Voltage 0 to 100 mV 0.01 mV 0.01%, Max load, 1 mA 0 to 10V (source) 0.01V 0.02% Rdg + 2 0 to 20 V (source) 0.01 V LSD0 to 30 V (measure) 0.01 V

mA 0 to 24 0.001 mA 0.01%; 0.02% Rdg Max load,+ 2 LSD 725/726: 1000

725Ex: 500

mV -10.00 mV to +75.00 mV 0.01 mV 0.01%(TC terminals) 0.02% of range +

1 LSD

Ohms 15 to 3200 0.01 to 0.10 to 1.05 to 4000 0.1 0.015%

Hz - CPM 2.0 to 1000 CPM 0.1 CPM ±0.05% Source; 1 to 1100 Hz 1 Hz ±0.05% 5V p-p 1.0 to 10.0 kHz 0.1 kHz ±0.25% 1V - 20 V p-p10.0 to 15.0 kHz 0.1 kHz ±0.05% squarewave,

-0.1 V offset

Loop Supply 725/726: 24 V DC N/A 10%725Ex: 12 V DC

T/C J, K, T, E, L, N, U, XK 0.1 ºC, 0.1 ºF to 0.7 ºCto 0.2 ºC

T/C B, R, S, BP 1 ºC, 1 ºF to 1.7 ºCto 1.2 ºC

RTDs Cu (10), Ni120 (672) 0.01 ºC, to 0.15 ºCPt 100, 200, 500, 1000 (385) 0.01 ºFPt 100 (3916),Pt 100 (3926) 0.1 ºC, 0.1 F to 0.2 ºC

Maximum voltage: 30VOperating temperature: 10°C to 55°CSafety: CSA C22.2 No. 1010.1:1992EMC: EN50082-1:1992 and EN55022:1994 Class B

Size (HxWxD): 200 mm x 96 mm x 47 mmWeight: 0.65 kgBattery: Four AA alkaline batteries. Battery life: 25 hours typical; battery doorWarranty 725, 726: Three yearsWarranty 725Ex: One year

Fluke 725

SpecificationsFeatures

Simultaneous Function Channel A Channel BCapability

24.000 mA DC M M or S

24.000 mA DC with M24 V loop supply

100.00 mV DC M or S

30.000V DC Measure M

20.000V DC Measure M or S10.000V DC Source20.000V DC Source

15 to 3200 Ohms M or S5 to 4000 Ohms

Thermocouple J, K, T, E, R, S, B, M or SM, L, U, N, XK, BP

RTD Cu 10, Ni120; Pt100 (392); M or SPt100 (JIS); Pt100, 200, 500, 1000 (385)

Pressure (requires Fluke 700PXX M M used as SModules)

Frequency; 10 kHz; (15 KHz) M or S

M = Measure S = Source/SimulateUnique 726 features are in bold725Ex: ATEX cerfified(Ex ATEX II IG EEX 1a IIB 171°C)

Unique 726 features are in bold

Fluke 726

Fluke 725Ex

Recommended Accessories(Not for hazardous zones)

Page 78: Fluke 2007

724 Temperature Calibrator

76

The temperature solution

The Fluke 724 Temperature Calibrator is apowerful yet easy-to-use calibrator. Use themeasure and source functions to test andcalibrate almost any temperature instrument.• Easy to read dual display lets you view

input and output simultaneously• Measure RTDs, thermocouples, ohms, and

volts to test sensors and transmitters• Source/simulate thermocouples, RTDs,

volts, and ohms to calibrate transmitters• Perform fast linearity tests with 25% and

100% steps

• Execute remote tests with auto step andauto ramp

• Power transmitters during test using looppower supply with simultaneous mAmeasurement

• Store frequently-used test setups for later use

Fluke 724

Features

Specifications

C25See page 94

TL220See page 88

TL81ASee page 87

80PK-25See page 92

80PK-3ASee page 92

Function Range Resolution Accuracy NotesMeasure or Source

Voltage 0 to 100 mV 0.01 mV 0.02% Rdg + Max load, 2 LSD 1 mA

0 to 10V (source) 0.001V0 to 30V (measure) 0.001V

mA (measure) 0 to 24 0.001 mA 0.02% Rdg + Max load,2 LSD 1000

mV -10.00 mV to +75.00 mV 0.01 mV 0.025% + of range + 1 LSD

Resistance 0 to 3200 (measure) 0.01 to 0.1 0.10 to 1.015 to 3200 (source)

Loop Supply 24V dc N/A 10%

Thermocouples J,K,T,E,L,N,U 0.1°C to 0.7°C

Thermocouples B,R,S 1°C to 1.4°C

RTDs Ni120 (672) 0.1°C to 0.2° CPt 100, 200, 500, 1000 (385)Pt 100 (3916)Pt 100 (3926)

Recommended Accessories

Maximum voltage: 30VOperating temperature: -10°C to 55°CSafety: CSA C22.2 No. 1010.1:1992EMC: EN50082-1:1992 and EN55022:1994 Class B

Size (HxWxD): 200 mm x 96 mm x 47 mmWeight: 0.65 kg Battery: Four AA alkaline batteriesBattery life: 25 hours typical; battery doorThree Year Warranty

Included AccessoriesTL75 Test Leads, AC72 Test Clips, one pairof stackable test leads.

Ordering InformationFluke 724 Temperature Calibrator

Simultaneous Function Channel A Channel BCapability24.000 mA DC M

24.000 mA DC with 24V loop Msupply

100.00 mV DC M or S

30.000V DC Measure M

20.000V DC Measure 10.000V DC M or SSource

0 to 3200 Ohms M or S

Thermocouple J, K, T, E, R, S, B, M or S L, U, N

RTD Ni120; Pt100 (3926); Pt100 M or S

(JIS); Pt100, 200, 500, 1000 (385)

M = Measure S = Source/Simulate

Page 79: Fluke 2007

712/714 TemperatureCalibrators

77

0.1°C, 0.1°F 0.33°C, 0.6°F Pt; 100 200 500(Pt 100) 1000 (385);

Pt 100 (3926);Pt 100 (3916) JIS;Ni 120 (672)

0.1

0.01 mV

C25See page 94

C550See page 94

TL970See page 87

TL220 (714)See page 88

80PK-24 (714)See page 92

The clear choice

The Fluke 710 Series Process Calibratorsoffer clear new choices in single-functioncalibrators. Whatever you want to measure- temperature, pressure or basic electricalparameters - you’ll find one of these easy-to-carry handheld tools gives you exactlythe functions you need. They combine therugged, ready-for-action package of theproven Fluke 80 Series DMMs with theeasy-to-use pushbutton operation of themultifunction Fluke 740 Series DocumentingProcess Calibrators. These calibrators areEMI tolerant, dust and splash resistant, andhave a removable battery door for quickbattery changes.

712 RTD Calibrator• Measure temperature from RTD output• Simulate RTD output• Rosemount pulsed RTD transmitter

compatible• Operates with seven types of RTDs• Measure additional RTDs using Ohms

measurement function• Simulate additional RTDs using Ohms

source function• °F or °C selectable• Four shrouded banana jacks

714 Thermocouple Calibrator• Measure temperature from TC output• Simulate TC output• Operable with nine types of thermocouples• Calibrate linear TC transmitter with

mV source function• Selectable °F or °C• Thermocouple mini-jack termination• Available as accessories; Fluke 700 TC1

and TC2 Thermocouple Mini-plug Kits

Specifications

Recommended Accessories

Maximum voltage: 30 V Operating temperature: -10°C to 55°CSafety: CSA C22.2 No. 1010.1:1992EMC: EN50082-1:1992 and EN55022: 1994 Class B712/714:Size (HxWxD): 201mm x 98 mm x 52 mm Weight: 0.6kgBattery: 9V alkaline Battery Life: 4 to 20 hours, typical, dependingon functions usedThree Year Warranty

Fluke 712

Included AccessoriesYellow Holster (H80M excl. TPAK), TL75 TestLeads and AC72 Alligator Clips (excludingmodel 714), single 9V alkaline battery andInstruction Sheet (14 languages)

Ordering InformationFluke 712 RTD CalibratorFluke 714 Thermocouple Calibrator

Fluke 714

Model Function Range Resolution Accuracy NotesFluke 712 Measure/simulate -200 to 800°C

RTD (Pt 100)

Measure/simulate 15 to 3200 0.1 to 1 Resistance

Fluke 714 Measure/ simulate -200 to 1800°C, 0.1°C or °F 0.3°C to 10 µV 9 TC types:Thermocouple depending on (1°C or °F; BRS) J K T E R S B per

type (K, -200 NIST 175 andto 1370°C) ITS-90, L U per DIN

43710 and IPTS-68Measure/ simulate -10 to 75 mV 0.025% +mV 1 count

Page 80: Fluke 2007

717/718/718ExPressure Calibrators

78

C43 (718)See page 94

C125 (717)See page 94

TL220See page 88

700P27See page 82

700LTPSee page 82

Pump up the pressure

717 pressure Calibrators• Measure pressure, 0.05% of full scale

with internal sensor- 1/8 NPT pressure fitting- Compatible with non-corrosive gasses

and liquids• Pressure measurement to 700 bar using

any of the Fluke-700Pxx Pressure Modules• Wide range of selectable measurement

units for pressure• Current measurement with 0.015%

accuracy and 0.001mA resolution• Simultaneous pressure and current

measurement for easy p/I or I/p testing• 24 volt loop power supply• Zero, Min-Max, Hold and Damping

functions• Pressure switch test captures set, reset

and deadband values

718 Pressure Calibrators• Same features as Fluke 717 plus• Newly designed built-in pressure/vacuum

hand pump with vernier and bleed valvehelps protect the pump from damage andis easier to clean

718Ex 30G and 100G IntrinsicallySafe Pressure Calibrator• Same features as Fluke 718

(excl. loop supply)• For use in explosion endangered areas• ATEX certified ( II 1G EEx ia IIC T4)

• Compatible with eight intrinsically safepressure modules

Included AccessoriesFluke 717: Yellow Holster (H80M excl. TPAK),TL75 Test Leads and AC72 Alligator Clips,Single 9V alkaline battery (two 9V batteries in718), Instructions. 718/718Ex: 718: YellowHolster, 718Ex: Red Ex Holster, TL75 Test Leadsand AC72 Alligator Clips, 700ILF In-Line Filter,two 9V batteries, user manual on CD-ROM.

Ordering InformationFluke 718 1G Pressure CalibratorFluke 718 30G Pressure CalibratorFluke 718 100G Pressure CalibratorFluke 718 300G Pressure CalibratorFluke 718Ex 30G Intrinsically Safe

Pressure CalibratorFluke 718Ex 100G Intrinsically Safe

Pressure CalibratorFluke 717 1G Pressure CalibratorFluke 717 30G Pressure CalibratorFluke 717 100G Pressure CalibratorFluke 717 300G Pressure CalibratorFluke 717 500G Pressure CalibratorFluke 717 1000G Pressure CalibratorFluke 717 1500G Pressure CalibratorFluke 717 3000G Pressure CalibratorFluke 717 5000G Pressure Calibrator

Specifications

For Fluke 717/718 models: Supported Pressure Units; psi, in. H2O(4°C), in. H2O(20°C), cm H2O(4°C), cm H2O(20°C), bar mBar, kPa, inHg, mmHg, kg/cm2

Functions: Zero, Min, Max, Hold, Damp functionsMax. Voltage: 30 VOperating temperature: -10°C to 55°CSafety: CSA C22.2 No. 1010.1:1992EMC: EN50082-1:1992 and EN55022:1994 Class BFluke 717: For use with non corrosive gasses and liquidsFluke 718: For use with non corrosive gasses

717Size (HxWxD): 201 mm x 98 mm x 52 mmWeight: 0.6 kgWarranty: Three years

718/718ExSize (HxWxD): 216 mm x 94 mm x 66 mmWeight: 0.992 kgWarranty 718: Three yearsWarranty 718Ex: One year

Fluke 718Model Range Resolution Over Pressure 718 1G -68.9 mbar to 68.9 mbar 0.001 mbar Over Pressure 5xFS 718 30G -850 mbar to 2 bar 0.1 mbar Over Pressure 2xFS 718 100G -850 mbar to 7 bar 0.1 mbar Over Pressure 2xFS 718 300G -850 mbar to 20 bar 1 mbar Over Pressure 375 PSI, 25 bar717 1G -68.9 mbar to 68.9 mbar 0.001 mbar Over Pressure 5xFS 717 30G -850 mbar to 2 bar 0.1 mbar Over Pressure 2xFS 717 100G -850 mbar to 7 bar 0.1 mbar Over Pressure 2xFS 717 300G -850 mbar to 20 bar 1 mbar Over Pressure 375 PSI, 25 bar717 500G 0 mbar to 34.5 bar 1 mbar Over Pressure 2xFS 717 1000G 0 mbar to 69 bar 1 mbar Over Pressure 2xFS 717 1500G 0 bar to 103.4 bar 0.01 bar Over Pressure 2xFS 717 3000G 0 bar to 207 bar 0.01 bar Over Pressure 2xFS 717 5000G 0 bar to 345 bar 0.01 bar Over Pressure 2xFS

Fluke 717

Fluke 718Ex

Recommended Accessories(Not for hazardous zones)

Page 81: Fluke 2007

705/707/707Ex/715Loop Calibrators

79

C12A (705/707)See page 94

C25 (715)See page 94

TL220See page 88

TP920See page 87

TPAK (715)See page 97

4-20 mA, source, measure, simulate

705 Loop Calibrator• Simultaneous mA and % • mA accuracy of 0.02%• Measure, source and simulate mA• Push button 25% steps for fast,

easy linearity checks • “Span Check” for fast confirmation of

zero and span• Selectable slow ramp, fast ramp,

and step function• 24 volt internal loop supply• 0 - 20 mA or 4 - 20 mA default

start up modes

707 Loop Calibrator• Features of the Fluke 705• “Quick Click” detented rotary knob for

one handed operation• Higher accuracy: 0.015% • Mains Voltage Input protection• 250 Ohm loop resistance for with

Hart instrumentation

715 Volt/mA Calibrator• Measure loop current (0-20 mA, 4-20 mA)

signals with 0.015% accuracy and 0.001 mA resolution

• Measure voltage output process signalsfrom PLCs, transmitters

• Source or simulate 24 mA loop current• Source voltage to 100 mV or 10V• 24V loop supply with simultaneous

current measurement

707Ex Intrinsically Safe LoopCalibrator• Same features as Fluke 707• For use in explosion endangered areas• ATEX certified ( II 2 G Eex ia IIC T4)

Functions 705/707/707 Ex 715Voltage measurementRange 0-28 V DC 0-200 mV, 0-20 VResolution 1 mV 10 µV 1 mVAccuracy 705: 0.025% Rdg + 2 LSD 0.01% Rdg + 2 LSD

707/707Ex: 0.015% Rdg + 2 LSD

Current measurementRange 0-24 mA 0-24 mAResolution 0.001 mA 0.001 mAAccuracy 705: 0.025% Rdg + 2 LSD 0.015%

707/707Ex: 0.015% Rdg + 2 LSD

Current sourcingRange 0-20 mA or 4-20 mA1 0-20 mA or 4-20 mA1

Accuracy 705: 0.025% Rdg + 2 LSD 0.015% + 2 LSD707/707Ex: 0.015% Rdg + 2 LSD

Drive capability 705: 1000 @ 24 mA 1000 @ 24 mA707: 1200 @ 24 mA707Ex: 700 @ 20 mA

Loop power while measuring mA 24 V 24 VVoltage sourcing N/A 0-100 mV or 0-10 VDisplay current and % of span Yes mA or %Auto step, auto ramp Yes YesSpan Check Yes Yes

Specifications

1 will over-range to 24 mA

Fluke 705, 707, 707Ex Maximum voltage: 30 V (28 V - 707Ex)Operating temperature: -10 to 55°CSafety: CSA C22.2 No. 1010.1: 1992EMC: EN50082-1:1992 and EN55022: 1994 Class BSize (HxWxD): 164 mm x 75 mm x 47 mm;Weight: 0.35 kgBattery: One 9 V alkalineBattery life: 18 hours typical, at 12 mAWarranty: Three years (one year, 707Ex)

715Size (HxWxD): 201 mm x 98 mm x 52 mmWeight: 0.6 kgBattery: One 9V alkalineBattery life: 4 to 20 hoursWarranty: Three years

Included AccessoriesFluke 705/707: C10 Yellow Holster, TL75 TestLeads, AC72 Alligator Clips, Single 9V alkalinebattery, Instruction SheetFluke 707Ex: Red Ex-holster, Fluke TL75Test Leads, AC72 Alligator Clips, Single 9Valkaline battery, Instruction SheetFluke 715: Yellow Holster (H80M excl. TPAK),TL75 Test Leads and AC72 Alligator Clips,Single 9V alkaline battery, Instruction Sheet

Ordering InformationFluke 705 Loop CalibratorFluke 707 Loop CalibratorFluke 707Ex Intrinsically Safe Loop

CalibratorFluke 715 Volt/mA Calibrator

Fluke 705

Fluke 707

Fluke 715

Fluke 707Ex

Recommended Accessories(Not for hazardous zones)

Page 82: Fluke 2007

771 mA Process Clamp Meter

80

Fluke 771

Included AccessoriesSoft carrying case, users manual

Ordering InformationFluke 771 Milliamp Process Clamp Meter

The Fluke 771 is the latest innovativeapproach to measuring mA loop signals. With the Fluke 771 you no longer need tolift a wire from a terminal (break the loop)to measure 4-20 mA which has a directimpact on your maintenance time. With theFluke 771 there is no need to call a controlroom to override the control of a processloop when breaking the loop and you savetime when testing analog I/O on a PLC ifyou do not need to check measurements ona console. In addition, the Fluke 771 canhave another impact on your overall costby eliminating catastrophic plant outagecaused by accidentally opening a criticalloop.

Measure 4-20 mA signals withoutbreaking the loop• Measure mA signals for PLC and control

system analog I/O• Measure 4-20 mA output signals from

transmitters without breaking the loop

• Best in class 0.2% accuracy• Resolution and sensitivity to 0.01 mA • Hold function captures and displays

changing measurements• Dual backlit display with both mA

measurement and percent of 4-20 mAspan

• Measurement Spotlight illuminates hardto see wires in dark enclosures

• Detachable clamp with extension cablefor measurements in tight locations

• Measure 10-50 mA signals in oldercontrol systems using the 99.9 mA range

• Automatic battery savings features- Power, 15 minutes automatic power

down- Backlight, 2 minutes, automatic off- Spotlight, 2 minutes, automatic offAutomatic battery saving features can be disabled if desired.

Function Range Resolution Accuracy Features

Measuring and troubleshooting -20.99 to 0.01 mA 0.2% or reading + Zero, Hold, 4-20 mA signals +20.99 mA 5 counts backlight,

measurementspotlight

Measuring and troubleshooting -21.0 to -99.9 mA 0.1 mA 1% reading + Zero, Hold, 10-50 mA signals +21.0 to +99.9 mA 5 counts backlight,

measurementspotlight

Specifications

Operating Temperature: -10 to 55 ºCStorage Temperature: -25 to 70 ºCOperating Humidity: < 95% @ <30 ºC, < 75% @ 30 to 55 ºCOperating Altitude: 0 to 2000 mIP Rating: IP 40Size (HxWxD): 212 mm x 59 mm x 38 mmWeight: 0.26 kg

Vibration: Random 2g, 5 to 500 HzShock: 1 meter drop test (except the jaw)Safety: EMI, RFI, EMC - Meets EN61326-1Temperature Coefficients: 0.01% / ºCBattery: AA 1.5 V Alkaline (2), IEC LR6Battery Life: 20 hours typicalWarranty: Three-years, electronics, 1-year for clamp cable assembly

Page 83: Fluke 2007

787/789 ProcessMeters

81

C125See page 94

TL220See page 88

80T-150USee page 92

i400See page 90

i410See page 91

Double your power

The Fluke 787 and 789 ProcessMeterscombine a Digital Multimeter and a LoopCalibrator in one rugged handheld tool,giving process technicians double the power. The Fluke 789 has a built-in 24 V loopsupply which reduces the need for taking aseparate power supply when doing offlinetransmitter testing. The IR communication

port of the Fluke 789 allows data to belogged to optional FlukeView Software forgraphical analysis and reporting.

Included Accessories787: Yellow Holster (H80M excl. TPAK), TL75Hard Point Test Lead Set plus AC72 AlligatorClips, one 9V battery, user manual789: TL71 Test Lead Set plus AC72 AlligatorClips, four 9V AA alkaline batteries, usermanual and quick reference guide.

Ordering InformationFluke 787 ProcessMeterFluke 789 ProcessMeterFVF-SC2 FlukeView Forms Software

including interface cable

Features

787 789

DMM and Loop Calibrator in one tool

Precision 1000 V, 440 mA True RMS Digital Multimeter

DC current source and Loop Calibrator

24 V Loop power supply

Min/Max / Average / Hold / Relative Modes

Diode Test and Continuity Beeper

Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp

Simultaneous mA and % of scale read-out

Externally accessible battery / fuses

HART mode setting with loop power and a built-in 250 resistor0% and 100% buttons to toggle between 4 and 20 mA sourcing for a quick span checkInfrared I/O serial port

787 789

Voltage measurements

Range 0-1000 V AC or DC 0-1000 V AC or DC

Resolution 0.1 mV to 1.0 V 0.1 mV to 1.0 V

Accuracy 0.1% Rdg+1 LSD (V DC) 0.1% Rdg+1 LSD (V DC)

Current measurement

Range 0-1 A 0-30 mA 0-1 A 0-30 mA

Resolution 1 mA 0.001 mA 1 mA 0.001 mA

Accuracy 0.2%+2 LSD 0.05%+2 LSD 0.2%+2 LSD 0.05%+2 LSD

Current Sourcing

Range 0-20 mA or 4-24 mA 0-20 mA or 4-24 mA

Accuracy 0.05% of span 0.05% of span

Other specifications

Max drive capability 500 1200

Loop power N/A 24 V

Resistance measurement To 40 M , 0.2%+1 LSD To 40 M , 0.2%+1 LSD

Frequency To 19.999 kHz, 0.005%+1 LSD To 19.999 kHz, 0.005%+ LSD

Continuity Beeps for resistance < 100 Beeps for resistance < 100

Span Check No Yes

Specifications

Maximum voltage: 1000 VOperating temperature: -20 to 55ºC

787Size (HxWxD): 201 mm x 98 mm x 52 mmWeight: 0.642 kgBattery: One 9 V alkalineBattery life: 12 to 50 hours typicalWarranty: Three years

789Size (HxWxD): 203 mm x 100 mm x 50 mmWeight: 0.6 kgBattery: Four AA alkaline batteriesBattery life: 14 to 140 hours typicalWarranty: Three years

Fluke 787

Fluke 789

/- /

True RMS

Recommended Accessories

Page 84: Fluke 2007

Field Calibrator Accessories

82

Fluke 700 Series Pressure Modules

• Ranges from 2.5 mbar to 700 bar.• Gage, differential, dual (compound),

absolute and vacuum modules• Very high accuracy: up to 0.025% FS• Full-accuracy performance for 0°C to 50°C• Pressure readings update twice per

second, and may be displayed in up to 11 different units

• Compatible with Fluke 717, 718, 725 and74x series.

• Rugged cases protect the modules from harsh environments

• All modules include NIST traceablecertificate and test data

• ATEX certified Ex versions available ( II 1 Eex ia IIB T4)

Model Range (approx.) Resolution Reference High side media Low side media Fitting material Max uncertainty overpressure2)

(23 ± 3°C) (FS)Differential700P00 2.5 mbar 0.001 mbar 0.3 % Dry 1) Dry 316 SS 30x700P01/700P01Ex 25 mbar 0.01 mbar 0.2 % Dry Dry 316 SS 3x700P02 70 mbar 0.007 mbar 0.15 % Dry Dry 316 SS 3x700P22 70 mbar 0.007 mbar 0.1 % 316 SS Dry 316 SS 3x700P03 340 mbar 0.01 mbar 0.05 % Dry Dry 316 SS 3x700P23 340 mbar 0.01 mbar 0.025 % 316 SS Dry 316 SS 3x700P04 1000 mbar 0.1 mbar 0.025 % Dry Dry 316 SS 3x700P24/700P24Ex 1001 mbar 0.1 mbar 0.025 % 316 SS Dry 316 SS 3xGage700P05/700P05Ex 2 bar 0.1 mbar 0.025 % 316 SS N/A 316 SS 3x700P06/700P06Ex 7 bar 0.7 mbar 0.025 % 316 SS N/A 316 SS 3x700P27/700P27Ex 20 bar 1 mbar 0.025 % 316 SS N/A 316 SS 3x700P07 34 bar 1 mbar 0.025 % 316 SS N/A 316 SS 3x700P08 70 bar 7 mbar 0.025 % 316 SS N/A 316 SS 3x700P09/700P09Ex 100 bar 10 mbar 0.025 % 316 SS N/A 316 SS 2xAbsolute700PA3 340 mbar 0.01 mbar 0.05 % 316 SS N/A 316 SS 3x700PA4/700PA4Ex 1000 mbar 0.1 mbar 0.05 % 316 SS N/A 316 SS 3x700PA5 2 bar 0.1 mbar 0.05 % 316 SS N/A 316 SS 3x700PA6 7 bar 0.7 mbar 0.05 % 316 SS N/A 316 SS 3xVacuum700PV3 -340 mbar 0.01 mbar 0.04 % 316 SS Dry 316 SS 3x700PV4 -1000 mbar 0.1 mbar 0.04 % 316 SS Dry 316 SS 3xDual700PD2 ± 70 mbar 0.007 mbar 0.15 % 316 SS Dry 316 SS 3x700PD3 ± 340 mbar 0.01 mbar 0.04 % 316 SS Dry 316 SS 3x700PD4 ±1000 mbar 0.1 mbar 0.025 % 316 SS Dry 316 SS 3x700PD5 -1000/+2000 mbar 0.1 mbar 0.025 % 316 SS N/A 316 SS 3x700PD6 -1000 mbar/+6.9 bar 1 mbar 0.025 % 316 SS N/A 316 SS 3x700PD7 -1000 mbar/+13.8 bar 1 mbar 0.04 % 316 SS N/A 316 SS 3xHigh700P29/700P29Ex 200 bar 0.01 bar 0.05 % C276 N/A C276 2x700P30 340 bar 0.01 bar 0.05 % C276 N/A C276 2x700P31 700 bar 0.07 bar 0.05 % C276 N/A C276 1.5x

Other accessories

700LTP Low-pressure Test Pump• For low pressure applications• Vacuum to – 0.85 bar• Pressure to 2 bar• With fine-control, adjustable relief valve

and slow bleed capability

700PTP Pneumatic Test Pump • Handheld pressure pump • Vacuum to -0.8 bar • Pressure to 25 bar

700HTP Hydraulic Test Pump• Pressure to 700 bar

700PRV Pressure Relief Valve Kit

700HTH Hydraulic Test Hose

700ILF In-Line Filter for the Fluke 718

700PCK Pressure Module Calibration Kit

BP7235 NiMH Battery Pack

BE9005 Battery Eliminator

1) “Dry” indicates dry air or non-corrosive gas as compatible media. “316 S S” indicates media compatible with Type 316 Stainless Steel.“C276” indicates media compatible with Hastelloy C276.

2) Maximum overpressure specification includes common mode pressure.

Fluke 700LTP Fluke 700PTP

Page 85: Fluke 2007

ATEX Certified Test Tools

The Fluke line of intrinsically safe tools is designed to meet the needsof technicians working in and around hazardous areas. The tools areideal for environments in chemical plants, petro-chemical plants, oilplatforms, refineries and other locations where risk of explosion exists.The products are easily recognizable from standard Fluke products bytheir lighter grey colour and red holster.

83

Page 86: Fluke 2007

A brief look at ATEX

The ATEX examination mark. This sign is required on all devices usedin European hazardous areas.

II 2 G The classification of zones.“II” designates the tool is approved for all non-mining areas. “2” represents the category of the device, in this case the device israted for the second most hazardous areas.“G” designates atmosphere, in this case gas, vapors and mist.

EEx Explosion protection based on European Ex-regulations.ia The type of protection from explosion, in this case the energy in a

device or connector has been reduced to a safe value.IIC Gas Group. “IIC” indicates compatibility with the most dangerous

gas group.T4 Temperature class gives the user the maximum temperature of a

surface that may be in contact to the Ex atmosphere under faultconditions. T4 is rated at 135°C.

What is “Intrinsically Safe”?Intrinsically safe standards apply to allequipment that can create one or more of arange of defined potential explosion sources:

• Electrical sparks• Electrical arcs• Flames• Hot surfaces• Static electricity• Electromagnetic radiation• Chemical reactions• Mechanical impact• Mechanical friction• Compression ignition• Acoustic energy• Ionizing radiation

What industries are intrinsically safe products designed for?• Petro-chemical• Oil platforms and refineries• Pharmaceutical• Bulk materials (e.g. grain)• Mining• Pipelines• Any environment where explosive gases

are present

What is ATEX?The primary intrinsically safe standard hasbeen set in the European Union with the9/94/EC Directive, commonly called ATEX(“Atmosphères Explosibles,” French forexplosive atmospheres). The stated goal ofthe guidelines is to “help ensure the freemovement of products in the EuropeanUnion” by “minimizing the number ofsafeguard clause applications, at least thoseoriginating from divergent interpretationsThe ATEX rules have been in place as avoluntary standard since 1 March 1996.The rules are mandatory on electrical andelectronic equipment for use in environmentssubject to explosion hazard sold in the EU

starting 1 July 2003. From this date onwards,all products sold for use in explosiveatmospheres must have ATEX certificationand carry the distinctive symbol:

The Fluke Ex (IS) product lineFluke is among the first manufacturers toproduce handheld test tools according tothe latest ATEX standards. The Fluke line ofintrinsically safe tools is designed to meetthe needs of technicians working in andaround hazardous areas:• Install, maintain and troubleshoot

equipment by using the new Fluke 87VEx Digital Multimeter

• Maintain and calibrate sensors,transmitters and control loops with theline of Ex field calibrators

The tools are ideal for environments inpetro-chemical plants, oil platforms,refineries and other locations subject to riskof explosion. Apart from having the ATEX markings, thevisual difference between a standard Fluketool and the corresponding Ex version isthe different grey body colour and a red,conductive holster designed specifically toeliminate the potential for electricaldischarge.Inside, the Fluke Ex tools have beenreengineered to reduce energy avoidinggeneration of heat and electrical sparks.They are premium products designed forultimate safety.

Making sense of ATEX certificationFluke 707Ex is ATEX-compliant and iscertified II 2 G EEx ia IIC T4— but whatexactly does that mean?

Here a brief explanation of the ATEXcertification designations.

Intrinsic safety is a protectionstandard employed in potentiallyexplosive atmospheres. Devices thatare certified as “intrinsically safe”are designed to be unable to releasesufficient energy, by either thermalor electrical means, to cause ignitionof flammable material (gas, dust/-particulates).

ATEX certification 707Ex

84

Page 87: Fluke 2007

ATEX-certified Test Tools

85

Fluke 87V Ex Intrinsically safeversion of the world’s most popularmultimeterWith its high performance, accuracy andmotor drive compatibility, the Fluke 87V isthe most popular industrial multimeteraround. Now Fluke has introduced a newintrinsically safe version – the 87V Ex – formeasurements in and around hazardousareas.The Fluke 87V Ex has all the measurementand troubleshooting functions of the provenFluke 87V. Unlike other ATEX-certified tools,it can be used both inside and outside thehazardous zone (ATEX Zones 1 & 2) withoutcompromising performance or compliance. So there’s no need to carry different toolsfor use in specific zones. It also has a built-inthermometer with TC probe, further reducingtechnicians’ tool counts.• ATEX safety rating II 2G Eex ia IIC T4• EN61010-1 CAT III 1000V/CAT IV 600V

electrical safety rating

See also page 15

Fluke 725Ex Intrinsically safeMultifunction Process CalibratorThe Fluke 725Ex intrinsically safeMultifunction Process Calibrator is powerfulyet easy-to-use. Combined with the Fluke 700PEx Pressure Modules, the 725Exis able to calibrate almost any processinstrument likely to need service in any areawhere explosive gases may be present. • ATEX safety rating

II IG Ex ia IIB 171°C

See also page 75

Fluke 707Ex Fast, one-handed toolfor loop checksThe Fluke 707Ex is the ideal, stand alonetool for calibration and maintenance of 4 to20 mA control loops. It provides 24V looppower while measuring mA, and lets youmeasure and source/simulate mA with 1 µAresolution.• ATEX safety rating

II 2G EEx ia IIC T4

See also page 79

Fluke 718Ex Self-contained PressureCalibratorThe Fluke 718Ex offers a convenient, selfcontained solution for pressuremeasurements and calibration. With itsinternal pressure sensor and pump, it’sready for immediate, stand alone use. Thepressure range can easily be extended to upto 200 bar with any of the 8 Fluke 700PExPressure Modules.• ATEX safety rating

II IG EEx ia IIC T4

See also page 78

Fluke 700Ex Pressure ModulesThese intrinsically safe pressure modulesfor use with the Fluke 725Ex MultifunctionalProcess Calibrator and Fluke 718Ex PressureCalibrator cover the most commonly usedpressure calibration ranges from 0-25 mbarand 0-200 bar.There’s a choice of 8 gage, differential andabsolute modules.• ATEX safety rating

II 1G EEx ia IIC T4

See also page 82

Fluke intrinsically safe tools for tough measurement andcalibration tasks

Fluke 87V Ex

Fluke 700Ex

Fluke 718Ex

Fluke 707Ex

Fluke 725Ex

Page 88: Fluke 2007

General Accessories

The best test tools deserve accessories designed and manufactured tothe same high quality and safety standards. So we also provide acomprehensive range of test leads, probes and clips, current clamps,temperature accessories and dedicated electronic and automotiveaccessories. And to protect your valuable instrument, choose a ruggedFluke tailor-made holster or case.

86

Page 89: Fluke 2007

87

Electronic Test Leads, Probes & Clips

TL910 Electronic Test Lead Set• Very small 1 mm tips to access hard

to reach test points• Probe tip length up to 100

mm, test lead length: 1 m

• Included: 3 sets ofspring loaded gold tipsand 2 sets of stainless steel tips

• CAT IV 600 V, CAT III 1000 V, 3 A rating

Test Leads Test Leads

Patch Cords

Kits

TL960 Micro-Hook Test Lead Set• 1 pair (red, black) of test leads with

multi-stacking 4 mm bananaplugs and micro-hooks

• Micro-hooks attach tocomponent leads up to 1 mmdiameter

• 90 cm long PVC insulated leads• 30 V rms or 60 V DC, 15 A

TP912 Replacement Tips for TL910• Replacement tips for TL910• Five sets of gold plated and stainless

steel tips

TL40 Retractable Tip Test Lead Set• One pair (red, black) of test leads with

sharp needle point tips adjustableto desired length from 0 to76 mm

• Extra hard probe tipsto provide long service life

• Flexible silicone insulated testleads

• CAT II 150 V, 3 A rating, UL listed

TL940 Mini-Hook Test Lead Set• 1 pair (red, black) of test leads with

multi-stacking 4 mm banana plugsand mini-hooks

• Mini-hooks attach tocomponent leads up to 1.5 mm diameter

• 90 cm long PVCinsulated leads

• 30 V rms or 60 V DC, 15 A

TL950 Mini-Pincer Test Lead Set• 1 pair (red, black) of test leads with

multi-stacking 4 mm bananaplugs and mini-pincers

• Mini-pincers open to 2.3 mm

• 90 cm long PVC insulatedleads

• 30 V rms or 60 V DC, 15 A

TL930 Patch Cord Set (60 cm)• 1 pair (red, black)

multi-stacking 4 mmbanana plug patchcords

• Nickel-platedbanana plugs

• 61 cm long PVC insulated leads

• 30 V rms or 60 V DC, 15 A

TL932 Patch Cord Set (90 cm)• 1 pair (red, black) multi-

stacking 4 mm bananaplug patch cords

• Nickel-platedbanana plugs

• 90 cm long PVC insulated leads• 30 V rms or 60 V DC, 15 A

TL935 Patch Cord Kit (60, 90, 120 cm)• 3 sets (red and black pairs) of

multi-stacking 4 mm bananaplug patch cords

• Nickel-plated banana plugs• 60 cm, 90 cm, 120 cm long

PVC insulated leads• 30 V rms or 60 V DC, 15 A

H900 Test Lead Holder• Heavy duty construction

with mounting holes• Holder has 10 slots for

wires up to 8 mm in diameter• Over-all dimensions: 27.9 cm

L x 8.9 cm W x 3.2 cm H

TP920 Test Probe Adapter Kit• Set of push-on adapters for

TL71 and TL75 test probes• IC test adapters, extended

probe tips, mediumalligator clips(max.opening 7.6 mm)

• CAT II 300 V, 5 A rating

TL970 Hook and Pincer Kit• Handy all-in-one kit that includes

3 Test Lead Sets:• TL940 Mini-Hook Test Lead Set• TL950 Mini-Pincer Test Lead

Set• TL960 Micro-Hook Test Lead

Set

TL80A Basic Electronic Test Lead Kit• One pair (red, black) each 1 meter long

silicone test lead set,alligator clip and probe tipextender.

• C75 soft carrying case• CAT II 300 V. UL listed

TL81A Deluxe Electronic Test Lead Kit• Includes components of TL80, plus one pair

(red, black) eachmodular 1 meter longsilicone test lead, testprobe, hook-style andpinch style clip,alligator clip, IC probetip adapter and spadelugs

• Quadfold soft carryingcase

• CAT II 300 V. UL listed

BP980 Double Banana Plug Kit• 5 pair (red, black) of double

4 mm banana plugs• Each plug has 3.1 mm

holes for mountingwires and components

• Brass plugs/jack,beryllium coppersprings

• 30 V rms or 60 V DC, 15 A

Page 90: Fluke 2007

Industrial Test Leads, Probes & Clips

88

TL27 Heavy Duty Test Lead Set• DMM test leads (red, black)

with safety shrouded,standard diameter bananaplugs

• Heavy duty EPDM insulation• Length 1.5 m• CAT III 1000 V, 10 A rating.

UL listed

TL71 Premium Test Lead Set• One pair (red, black) comfort grip

probes with siliconeinsulated, right-angletest leads

• Recommended forµV measurements

• CAT IV 600 V, CATIII 1000 V, 10 Arating. UL listed

TL75 Hard Point™ Test Lead Set• One pair (red, black) comfort grip

probes with PVC insulated,test leads with right-angle shroudedbanana plugs

• Recommended forgeneral purposemeasurements

• CAT IV 600 V, CAT III 1000 V,10 A rating. UL listed

TL76 All-in-one Test Lead Set• One pair (red, black) 1.5 meter long

silicone test leads with rightangle shrouded bananaplug

• Lantern tip (removable) foruse with European wallsockets (4 mm Ø )

• Lantern tip can be removed foreasy access to terminal blocks (2 mm Ø)

• Removable, insulated IC caps allow probingon closely spaced leads and compliancewith GS38.

• Cat IV 600 V, CAT III 1000 V, 10 A rating, UL listed

TL221 SureGrip™ Extension Lead Set• One pair (red, black) of silicone

insulated leads with straightconnectors on both ends

• Reinforced strain relief• Includes one pair (red, black)

of female couplers• Extends test leads by 1.5 m• 600 V CAT IV, 1000 V CAT III,

10 A rating. UL listed

TL222 SureGrip™ Silicone Test Lead Set• DMM test leads (red, black)

with safety shrouded, standarddiameter banana plugs

• Right angle connector on both ends

• Reinforced strain relief• 1.5 meter silicone-insulated

wire resists heat & cold• CAT IV 600 V, CAT III 1000 V,

10 A rating. UL listed

TL224 SureGrip™ Silicone Test Lead Set• DMM test leads (red, black)

with safety shrouded,standard diameter bananaplugs

• Right angle connector on oneend and straight connector on the other

• Reinforced strain relief• 1.5 meter silicone-insulated wire resists

heat & cold• CAT IV 600 V, CAT III 1000 V, 10 A rating.

UL listed

TLK-220 EUR SureGrip™ Accessory KitHandy all-in-one kit thatincludes:• AC220 SureGrip™ Alligator

Clip Set• AC285 SureGrip™ Large Jaw

Alligator Clip Set • TP74 Slim Reach Test Probe Set (4 mm)• TL224 SureGrip™ Silicone Test Lead Set• Large zippered soft case with moveable

divider

TLK-225 SureGrip™ Master Accessory KitKit includes all the SureGrip™leads and probes in a handy roll-up pouch:• AC220 SureGrip™ Alligator

Clip Set• AC280 SureGrip™ Hook Clip Set • AC283 SureGrip™ Pincer Clip Set • AC285 SureGrip™ Large Jaw

Alligator Clip Set • TP220 SureGrip™ Test Probe Set• TL224 SureGrip™ Silicone Test Lead Set• 6-Pocket Storage Pouch

TL220 SureGrip™ Industrial Test Lead KitHandy all-in-one kit that includes:• AC220 SureGrip™ Alligator

Clip Set• TP220 SureGrip™ Test

Probe Set• TL222 SureGrip™

Silicone Test LeadSet (right to right)

TL223 SureGrip™ Electrical Test Lead KitHandy all-in-one kit that includes:• AC220 SureGrip™ Alligator

Clip Set• TP1 Slim-Reach™ Test

Probes (flat bladed)• TL224 SureGrip™

Silicone Test Lead Set(straight to right)

TL238 SureGrip™ High Energy TestLead KitKit includes:• TP238 SureGrip™ Insulated Tip

Test Probes with less than4 mm of exposed metal(GS38) with flexibleremovable finger banner

• TP280 20 cm Test ProbeExtenders

• TL224 SureGrip™ Silicone Test Lead Set

SureGrip™ accessories are designed toimprove steadiness in slippery hands.Rubber overmolded surfaces and finger-hugging curves give the user acomfortable, reliable grip on theaccessory so they can focus on making anaccurate measurement.

Test Leads Modular Test Leads Kits

Page 91: Fluke 2007

Industrial Test Leads, Probes & Clips

89

Kits

Modular Test Probes(for use with Modular Test Leads)

Modular Test Probes(for use with Modular Test Leads)

Modular Clips(for use with Modular Test Leads)

Push-on Clip(for use with TL71 and TL75 Test Lead Sets)

Modular Clips(for use with Modular Test Leads)

ACC-T5-KIT Accessory Kit foruse with T5This kit completes the offering of aT5 with add-on probes and carrying case.• TP220 SureGrip™ Test Probe Set• AC285 SureGrip™ Large Jaw

Alligator Clip Set • C33 Soft Meter Case

TP1, TP4, TP38 SlimReach Test Probe Sets• One pair (red, black) of slender probes for

closely spaced or recessed terminals• TP1: Flat blade design to hold

securely in blade type wallsockets

• TP2: 2 mm diameter tip forelectronics work. Alsocompatible with AC72.

• TP4: 4 mm diameter tip designedto fit into IEC wall outlets

• TP38: Insulated probe tip(designed to meet GS38 specs forUnited Kingdom).

• CAT IV 600 V, CAT III 1000 V, 10 A rating, UL listed

L215 SureGrip™ Kitwith Probe Light andExtender• L200 Probe Light• TP280 20 cm Test

Probe Extenders• TP220 SureGrip Test Probes• TL224 SureGrip Silicon Test Lead Set• Foldable soft pouch with six pockets and

hook-and-loop

TP220 SureGrip™ Test Probe Set• One pair (red, black) of Industrial test probes• Sharp, 12 mm stainless steel tip

provides reliable contact• Flexible finger barrier improves

grip• Recommended for use

with TL222 and TL224 test leads

• CAT IV 600 V; CAT III1000 V, 10 A rating. UL listed

TP74 Lantern Tip Test Probe Set• One pair (red, black)• Tips include banana-style spring

contacts with nickel-platedbrass ends

• CAT III 1000 V, 10 A rating.UL listed

TP80 Electronic Test Probe SetRecommended for use with TL222and TL224• One pair (red, black)• IC insulated cap prevents

shortening of IC legs forprobing high densitycomponents or boards

• CAT III 1000 V, 10 A rating. UL listed

AC220 SureGrip™ Alligator Clip Set• One pair (red, black) of small, insulated,

nickel plated jaws• Blunt tip grabs round screw

heads up to 9.5 mm• Recommended for use with

TL222 and TL224 test leads• CAT IV 600 V, CAT III

1000 V, 10 A rating. UL listed

AC280 SureGrip™ Hook Clip Set• One pair (red, black) of nickel plated clips• Profile narrows to 5.6 mm at tip,

hook opening 6.4 mm at front, 2 mm at base

• Recommended for usewith TL222 and TL224test leads

• CAT IV 600 V, CAT III1000 V, 3 A rating. UL listed

AC283 SureGrip™ Pincer Clip Set• One pair (red, black) of nickel plated

pincers open to 5 mm• 11.4 cm flexible insulated shaft• Recommended for use

with TL222 and TL224test leads

• CAT IV 600 V, CAT III1000 V, 1 A rating. UL listed

AC285 SureGrip™ Large Jaw Alligator Clip Set• One pair (red, black) of large alligator

clips with nickel-plated steel jaws• Multi-purpose tooth pattern grips

anything from fine gauge wire toa 20 mm bolt

• Recommended for use with TL222and TL224 test leads

• CAT IV 600 V; CAT III 1000 V, 10 A rating. UL listed

AC87 Heavy Duty Bus Bar Clip Set• One pair (red, black) of flat, right

angle design for connecting tobus bars

• Adjustable collarprovides 2 ranges of jawopenings up to 30 mm

• CAT III 600 V, 5 A rating. UL listed

AC89 Heavy Duty Insulation Piercing Test Clip• Single probe pierces 0.25 to

1.5 mm insulated wire• Small pin allows self-

healing of the insulation• CAT IV 600V, CAT III 1000 V, 5 A rating.

UL listed

TLK291 Fused Test Probe Set• One pair (red, black) fused test probes• Designed to meet GS38 specs for

United Kingdom• CAT III 1000V, 0.5A• Fuse rating:

500 mA/1000 V/FF/50kA

AC72 Alligator Clip Set• Slide-on alligator clips (red, black)

for TL71/TL75• Jaws provide 8 mm opening• CAT IV 600 V, CAT III 1000 V,

10 A rating. UL listed

All accessories have a one year warranty

TLK290 Test Probe Kit • Kit includes three flexible socket probes

and a large alligator clip • To be used on three phase

sockets. • Probes have flexible width

test points that fit securely in 4 to 8 mm sockets.

• CAT III 1000 V, 8 A

Page 92: Fluke 2007

Current Clamps

90

AC Models

Specifications

Current Clamp Compatibility Chart

AC Modelsi5Si200i200si400i400si1000si2000flexi3000si3000flexAC/DC Modelsi30i30s80i-110si410 / i410 kiti1010 / i1010 kitOther90i-610s*

2 2 2 2 2 2 2 2 2 2 2 22 2 2 2 2 2 2 2 2 2 2 2

2 2 2 2 2 2 2 2 2 2 2 2 3 3 1 1 1

3 3 1 1 1

2 2 2 2 2 2 2 2 2 2 2 2

* For specifications of 90i-610s see page 961 For DC only2 Requires PM 9081 (see page 71)3 Requires PM 9082 (see page 71)

i5s i200 i200s i400 i400s i1000s i2000flex i3000flex i3000s

114/

115/

115/

117

175/

177/

179

187/

189

27 8845

A/8

846A

77 I

V

83V

/87V

88V

43B

430

Seri

es

120

Seri

es

190

Seri

es

1577

/158

7

715

724

725

741B

/743

B/7

44

787

789

New New

Nominal current range(s)

Continuous AC current range

Highest current

Lowest measurable current

Basic accuracy (48-65 Hz) 1)

Useable frequency

Max. working voltage

Maximum conductor diameter

Output level(s)

Batttery, battery life

Output cable (m)

Shrouded banana plugs

BNC adapter

BNC to banana adapter included

Safety

1) Basic Accuracy: % reading + floorspec

i5s i200 i200s i400 i400s i1000s i2000 flex i3000s flex-24 i3000si3000s flex-36

5 A 200 A 20 A 400 A 40 A 10 A 20 A 30 A 30 A200 A 400 A 100 A 200 A 300 A 300 A

1000 A 2000 A 3000 A 3000 A

0.01 A - 6 A 0.5 A - 200 A 0.1 - 24 A 5 A - 400 A 0.5 - 40 A 0.1 A - 10 A 1 A - 20 A 1 A - 30 A 1 A - 30 A 0.5 A - 200 A 5 A - 400 A 0.1 A - 100 A 2 A - 200 A AC RMS 2 A - 300 A AC RMS 1 A - 300 A

1 A - 1000 A 30 A - 2000 A 30 A - 3000 A 1 A - 2400 A

70 A 240 A 240 A 1000 A 1000 A 2000 A 2500 A AC RMS 3500 A AC RMS 4000 A

10 mA 0.5 A 0.5 A 1 A 0.5 A 0.1 1 A 1 A 1 A

1% 1% + 0.5 A 1.5% + 0.5 A 2% + 0.15 2% + 0.15 1% + 1 A 1% 1% 2% + 2 A

40 Hz - 5 kHz 40 Hz – 10 kHz 40 Hz – 10 kHz 45 Hz - 3 kHz 45 Hz - 3 kHz 5 Hz – 100 kHz 10 Hz - 20 kHz (-3dB) 10 Hz - 50 kHz (-3dB) 10 Hz - 100 kHz

600 V AC 600 V AC 600 V AC 1000 V 1000 V 600 V AC 600 V AC RMS 600 V AC RMS 600 V AC

15 mm 20 mm 20 mm 32 mm 32 mm 54 mm 178 mm Flex-24 178 mm 64 mmFlex-36 275 mm

400 mV/A 1 mA/A 100 mV/A 1 mA/A 10 mV/A 100 mV/A 100 mV/A 100 mV/A 10 mV/A10 mV/A 1 mV/A 10 mV/A 10 mV/A 10 mV/A 1 mV/A

1 mV/A 1 mV/A 1 mV/A 0.1 mV/A

200 hours 400 hours

2.5 1.5 2.0 1.5 2.5 1.6 0.5 0.5 2.1

n/a

n/a

n/a

CAT III, 600 V CAT III, 600 V CAT III, 600 V CAT III 1000V / CAT III 1000V / CAT III, 600 V CAT III, 600 V CAT III, 600 V CAT III, 600 VCAT IV 600 V CAT IV 600 V

Page 93: Fluke 2007

Current Clamps

91

i5sPQ3 AC Current Clamp, 3-packA pack of 3 pieces of the i5s current clamps,specially configured to provide low currentaccuracy while taking measurements onsecondary current transformers. This cost-saving 3-pack is perfect for use with 3-phase tools such as the Fluke 434 orFluke 435.

Specifications

AC/DC Models

80i-110s i30 i30s i410 i1010

80i-110s i30 i30s i410 i1010

Hall sensor Hall sensor Hall sensor Hall sensor Hall sensor

10 A, AC/DC 20 A AC RMS or DC 20 A AC RMS or DC 400 A, AC/DC 600 A, AC100 A, AC/DC 1000 A, DC

0.1A – 10 A AC/DC 30 A AC Peak 30 A AC Peak 1 A – 400 A AC/DC 1 A – 600 A, AC1 A – 100 A AC/DC 1 A – 1000 A, DC

140 A – 2 kHz 30 A AC Peak 30 A AC Peak 400 A 1000 A

0.1 A 50 mA 50 mA 0.5 A 0.5 A

3% + 50 mA (@ 10 A) ± 1% of reading ± 2mA ± 1% of reading ± 2mA 3.5% + 0.5 A 2% + 0.5 A

DC – 100 kHz DC to 20 kHz (-0.5dB) DC to 100 kHz (-0.5dB) DC – 3 kHz DC – 10 kHz

manual adjust via thumbwheel manual adjust via thumbwheel

600 V 300 V AC RMS 300 V AC RMS 600 V 600 V

11.8 mm 19 mm 19 mm 30 mm 30 mm2 x 25 mm 2 x 25 mm

100 mV/A 100 mV/A 100 mV/A 1 mV/A 1 mV/A10 mV/A

9 V, 55 h 30 hours typical 30 hours typical 9 V, 60 h 9 V, 60 h

1.6 1.5 2 1.6 1.6

n/a

n/a

n/a

CAT II, 600 V CAT III, 300 V CAT III, 300 V CAT III, 600 V CAT III, 600 VCAT III, 300 V

Measurement type

Nominal current range(s),

Continuous current range

Highest current

Lowest measurable current

Basic accuracy 1)

Useable frequency

Zero error adjustment

Max. working voltage

Maximum conductor diameter

Output level(s)

Battery, battery life

Output cable length (m)

Shrouded banana Plugs

BNC adapter

BNC to banana adapter included

Safety

1) Basic Accuracy: % reading + floorspec

i410 Kit AC/DC Current Clamp(400A) with soft casei1010 Kit AC/DC Current Clamp(1000A) with soft case• Combination of current clamp with

carrying case• Zippered soft case with moveable divider• Soft case is large enough to hold a meter

i3000flex, 4-pack• The perfect accessory for three-phase

measurement tools • The flex clamps fit around bus bars and

large or hard-to-reach conductors • Buy 4-pack and save 35% on the price

of the individual items

All accessories have a one year warranty

New

New New

Page 94: Fluke 2007

Temperature Accessories

92

Contact Probes DMM Probes

80PK-22 SureGrip™ Immersion Probe• Type-K thermocouple for use in

liquids and gels• Measurement range:

-40 to 1090°C

80PK-24 SureGrip™ Air Probe• Type-K thermocouple for use in

air and non-caustic gasmeasurements

• Bead protected by perforated baffle

• Measurement range:-40 to 816ºC

80PK-25 and 80PT-25 SureGrip™Piercing Probe• 80PK-25: Type-K thermocouple

suitable for food industry,liquids and gels

• 80PT-25 operates withT-type thermometers

• Measurement range: 80PK-25: -40 to 350°C80PT-25: -196 to 350°C

80PK-26 SureGrip™ General PurposeProbe• Type-K thermocouple with tapered tip

for use in air, non-caustic gas andsurface applications

• Measurement range:-40 to 816ºC

80PK-27 SureGrip™ Industrial SurfaceProbe• Type-K thermocouple for surfaces in

rugged environment• Durable ribbon sensor• Measurement range: -

127 to 600°C

80PK-1 and 80PJ-1 Bead Probe• 80PK-1: Type-K thermocouple for

general purpose applications• 80PJ-1 operates with J-

type thermometers• Measurement

range:-40 to 260°C

80PK-3A Surface Probe• Type-K thermocouple for flat or

curved surfaces such asplates and rollers

• Measurementrange: 0 to 260°C

80PK-8 Pipe Clamp Temperature Probe• Type-K thermocouple for

fast temperature andsuperheat measurements of pipe surfaces

• Durable ribbon sensor• Measurement range:

-29 to 149°C for pipediameters from 6.4 to 34.9mm

80PK-9 and 80PJ-9 General Purpose Probe• 80PK-9: Type-K thermocouple surface,

air and non-caustic gases• 80PJ-9 operates with J-type

thermometers• Measurement

range:-40°C to 260°C

80PK-11 Velcro Temperature Probe• Type-K thermocouple

for hands freemeasurement ofHVAC temperaturemeasuringapplications

• Total length ofcable: 1m (0.5m incable, 0.5m in Velcro cuffinsulation material; Hytrel)

• Measurement range: -30ºC to 105ºC

80AK Thermocouple Adapter• Adapts Type-K thermocouple

mini-connector to dual banana plug inputs

• Measurement range andaccuracy: probe dependent

• Suitable for low voltage applications (below 30 V AC, 60 V DC)

80BK Integrated DMM Probe• Type-K thermocouple with

standard banana jack• Convenient one piece

construction• Compatible with DMMs

with temperaturemeasurement functions

• Measurement range: -40 to 260ºC

80TK Thermocouple Module• Converts a DMM to a thermometer• For use with type-K

thermocouples in lowvoltage applications(below 24 V AC, 60 V DC)

• Measurement range: -50 to 1000°C (probe dependent)

80T-150U Universal TemperatureProbe• Compatible with Fluke DMM• High accuracy, fast reading for low voltage

(below 24 V AC, 60 V DC)applications

• Measurement range: -50 to 150°C

• Output: 1 mV/°C or 1mV/°F (switchable)

SureGrip™ accessories are designed toimprove steadiness in slippery hands.Rubber overmolded surfaces andfinger-hugging curves give the user acomfortable, reliable grip on theaccessory so they can focus on makingan accurate measurement.

Page 95: Fluke 2007

93

Temperature Accessories

Other Temperature Accessories

80CK-M & 80CJ-M type K & J MaleMini-Connectors• Isothermal screw terminal for

K or J wire• Suitable for up to

20 guage thermocouplewire

• Color coded to industrystandards(K-yellow, J-black)

• Two per package

80PK-EXT, 80PJ-EXT and 80PT-EXT Extension Wire Kits• Extending and repairing J, K ot T-type

thermocouple wires• Kit includes 3 meters of thermocouple wire

and 1 pair of male/female mini-connectors• Maximum continuous exposure temperature:

260ºC• 80PK-EXT is compatible with

K-type thermometers, 80PJ-EXT is designed for J-type thermometers and PT-EXT for T-typethermometers

Thermocouple Plug Kits700TC1A kit of 10 mini-plugconnectorsType J (black), oneType K (yellow), oneType T (blue), oneType E (purple), oneType R/S (green), oneType B or CU (white), oneType L (J-DIN) (blue), oneType U (T-DIN) (brown), oneType C (red), oneType N (orange), one

700TC2A kit of 7 mini-plug connectorsType J (black), twoType K (yellow), twoType E (purple), oneType T (blue), oneType R/S (green), one

Contact Probes80PK-1 … 80PK-2780PJ-1, 80PJ-980PT-2580PK-11DMM probes80AK80BK80TK80T-150UMiscellaneous80CK-M80CJ-M80PK-EXT80PJ-EXT80PT-EXT700TC1, 700TC280PR-60

114/

115/

116/

117

175/

177

179

187/

189

27 8845

A/8

846A

77IV

83V

87V

88V

43B

120

Seri

es

190

Seri

es

1577

1587

51/5

2/53

/54

II

561

66/6

8

705/

707

714

715

724

725

741B

/743

B/7

44

787

789

Temperature Probe Compatibility Chart

80PR-60 RTD Temperature Probe• For simulaneously taking contact and non-

contact temperaturemeasurementswith Fluke 66 or 68

• Measurementrange: -40 to 260°C

All accessories have a one year warranty

1) Requires 80TK2) Requires 80AK3) Fluke 16 only

1 1 2 2 1 1 1 1 2 2 1 1 1 1 2 1 1 1 1

1

3)

3)

1 1 1

1 1 1

Page 96: Fluke 2007

Cases and Holsters

94

C195 • Zippered carrying case with

storage compartments• Allows hand or

shoulder use

C789• Large fabric carrying case

with 3 compartments,removable handle andshoulder strap

C550 Tool Bag • Steel reinforced frame• Rugged ballistic cloth

with heavy dutyhardware

• Large zippered storagecompartment with25 pockets

• Weather resistant• Carry all your tools to the job

Zippered carrying cases protect your meter;most cases come with belt loops so your meteris stored conveniently on your tool belt.

Soft Cases

Cases & Holsters Compatibility Chart

C12A C23 C25 C33 C570

C43 C50 C75 C90 C125/C781

Soft Cases Size (HxWxD) mmC12A 172 x 128 x 38C23 225 x 95 x 58C25 218 x 128 x 64C33 280 x 115 x 55C43 318 x 230 x 90C50 192 x 90 x 38C75 179 x 103 x 26C90 205 x 90 x 72C125 192 x 141 x 58C195 231 x 513 x 231C550 333 x 513 x 231C570 240 x 160 x 61C781 269 x 141 x 90C789 308 x 256 x 77Hard CasesC20 256 x 154 x 106C100 397 x 346 x 122C101 305 x 360 x 105 C120 346 x 397 x 128C190 410 x 474 x 135C435 565 x 476 x 305C800 230 x 385 x 115C1600 260 x 390 x 200Leather CasesC510 287 x 179 x 106C520A 256 x 154 x 106HolstersC10 154 x 77 x 45C70Y 186 x 90 x 45H80M 190 x 95 x 43OtherH3 231 x 90 x 64H5 192 x 90 x 38H6 302 x 178 x 57Hanging and Locking Kits (see page 97)ToolPakLockPak

114/

115/

116/

117

175/

177/

179

187/

189

27 77 I

V

83V

/87V

/88V

T5 T50

T100

Ser

ies

321/

322

333/

334/

335/

336/

337/

902

1503

/150

7/57

7/58

7

904

0/9

062

1735

/174

0 Se

ries

430

Seri

es

43B

/120

Ser

ies

190

Seri

es

971

51/5

2/53

/54

II

561

570

Seri

es

61

63/6

6/68

705/

707

712/

714/

715/

717

718

724/

725/

726

741B

/743

B/7

44

787

789

For multiple test leads and accessories

For multiple meters, test leads and accessories

For multiple meters, accessories and other tools

715

Page 97: Fluke 2007

Cases and Holsters

95

C20 Meter Case• Heavy duty case with

carrying handle andaccessories storagecompartment

• Top cover snaps onto back to serve as tilt stand

C100 Meter and Accessory Case• Tough polyprophylene case

C101 Hard Case The hard case that fits all Flukeindustrial test tools. Configurethe diced foam interior to storeand protect what you need tocarry with you. • Tough polyprophylene exterior shell• Interior cavity measures

C120 and C190 Cases• Heavy duty cases with

accessory storagecompartments

C435 Hard Rolling Case• Water-tight hard case

with rollers for 430 Series,1735 and 1740 SeriesPower Quality products andaccessories. Theconfigurable foam securelyholds any of theseinstruments during transit.

C800 Meter and Accessory Case• Tough polyprophylene case• Accessories and manual

compartments• Detachable lid

C1600 Meter and Accessories Case• Rugged molded plastic case• Deep interior large enough to hold

and protect your tools• Lift out tray keeps everything

organized• Snap open compartment on

top of lid

C10 Meter Holster• Snap-on yellow holster

absorbs shocks and protectsmeter from rough handling

• Includes built-in stand andhanger loop

C70Y Meter Holster• Snap-on holster absorbs

shocks and protects meterfrom rough handling.

• Flex Stand™ allows meter tohand, lean or stand forconvenience and bestviewing

• Built-in probe and lead storage

H80M Holster + Magnetic Hanger• Snap-on yellow holster

absorbs shocks andprotects meter from roughhandling

• Magnet, hook and loop straps• General purpose hanger

H3 Clamp Meter Holster• Fabric holster absorbs shocks and protects

meter from rough handling.• Built-in pocket for lead

storage• Convenient belt-loop with

snap

H5 Electrical Tester Holster• Rugged fabric holster includes flap for lead

storage and built-in beltloop

• Fits Fluke T3 and T5testers

H6 Infrared Thermometer Holster• Durable nylon holster• For Fluke 63, 65 and 68

Infrared Thermometers

C520A Leather Tester Case • Oiled genuine top grain cowhide• Oil tanned for long life• Rugged construction with heavy duty

stitching and reinforced rivets• Large tool belt loop and top

flap to secure tester• Holds Fluke Electrical

Testers

C510 Leather Meter Case • Oiled genuine top grain cowhide• Rugged construction with heavy duty

stitching and reinforced rivets• Large tool belt loop and top

flap to secure meter• Holds most Fluke DMMs,

Thermometers, andProcess Calibrators

Hard Cases Holsters

Leather Cases

All accessories have a one year warranty

New

Page 98: Fluke 2007

Automotive Accessories

96

Piercing Clips

Probe Pins

Banana Plugs

Pressure Module

Test Leads

Current Probe

Inductive Pick-up

ScopeMeterAccessory Kits

TP81 and TP82 Insulation PiercingClip Set • Banana jack accepts all DMM

and banana jack leads• Available for 4 mm input,

modular connection withTP81 or available as a 2 mm input to sliponto probe tips with the TP82

• Tested to 60 V DC

TP84 Oxygen Sensor InsulationPiercing Clip• Banana jack accepts all

DMM and bananajack leads (4 mm)

• Tested to 60 V DC

TP88 Rigid Back Probe Pin Set• Slides onto test probes measuring

2 mm• Tested to 60 V DC

TP40 Automotive Back Probe Pins (five)• Banana jack accepts all DMM

and banana jack leads (4 mm)• Tested to 60 V DC

BP880 BNC to Female Double StackingBanana PlugBP881 BNC to MaleDouble Stacking BananaPlug• Allows for hands-free

testing in controlled voltageenvironments 500 VRMSmaximum

• Banana plug is nickel-plated, berylliumcopper for low contact resistance

• The BNC shell is plated for tarnishresistance

• Operating temperature +50°C maximum

TL28A Automotive Test Lead Set• Flexible silicone insulated leads

are heat and cold resistant• Cat I 30 V, 10 A

PV350 Pressure Vacuum Module• Compatible with all Fluke

and most popular DMMs• Digital pressure and

vacuum measurements in a single module

• Transducer sealed in 316 stainless steelcompatible with variety of liquids and gases

• Measures vacuum to 76 cm Hg• Display results in English (psig or Hg) or

metric (kPa or cm Hg) units• Measures pressure to 500 psig (3447 kPa)

BP880

BP881

TLK281 SureGrip™AutomotiveTest Lead KitKit contains:• TP81 Insulation

Piercing Clip Set• TL224

SuregripTM

Silicone TestLead Set

• TP220 SuregripTM Test Probe Set• AC220 SuregripTM Alligator Clip Set• AC285 SuregripTM Large Jaw Alligator Clip Set• Soft Case

TLK282 SureGrip™Deluxe AutomotiveTest Lead KitKit contains:• TP81 Insulation

Piercing Clip Set• TP40

Automotive BackProbe Pins (five)

• TL224 SuregripTM

Silicone Test Lead Set• TP220 SuregripTM Test Probe Set• AC220 SuregripTM Alligator Clip Set• AC285 SuregripTM Large Jaw Alligator

Clip Set• AC280 SuregripTM Hook Clip Set• Soft Case

90i-610s AC/DC Current Probe (600 A)• Current Range: 2 to 600A DC or

AC Peak • Basic Accuracy (DC to 400Hz):

± (2% of reading + 1A) • Output Signal: 100A range:

10mV/A 600A range: 1mV/A • Frequency Range: 40Hz to

400Hz• Working Voltage: 600V

AC rms • Maximum Conductor Diameter: 34 mm

RPM80 Inductive Pick-up• Provides RPM readings

TL 82 Automotive Pin & Socket Adapter KitThis set of male and femaleadapters allows you to make firmconnection to pin and socketconnectors. Kit contains: • Retractable shrouded test lead set• Complete set of 8 pin-and-socket

adapters with flexible tips• One red and black in different sizes• Rated to 60 V DC

SCC128AutomotiveAccessory Kit (120 Series)

SCC198AutomotiveAccessory Kit (190 Series)

These kits provide a host of accessories thatallow you to easily and quickly makemeasurements on automotive electronicsystems using a 120 or 190 Series ScopeMeter.

Page 99: Fluke 2007

FOC Fiber Optic Patch CordsA variety of patch cords allow you to test adifferent type of cable• FOA-ST/STA-Fiber Optic Coupler for

FOC-ST/ST Patch Cords

FOM Fiber Optic MeterThe Fluke Fiber Optic Meter (FOM) helps youtest and maintain fiber optic cables withouthaving to buy a whole newmeter. Plug the FOM directly into any DMM witha mV dc function and a 10M input impedance andquickly and accurately verify fiberoptic cable system loss. Light sources andpatch cords sold separately.

FOS 850 & FOS 850/1300Fiber Optic Light SourcesA variety of light sources allow you to testdifferent cable lengths.

LockPak (LPAK)The meter locking solution• Kit includes a locking

accessory• Attaches to back of a

187/189 meter or724/725/789 to helpdeter theft

• Accepts most commonlocks (not included)

Software and otherAccessories

97

Fiber Optics

Sofware FlukeView® Forms

Make extended logging easier

Hanging & Locking Kits

ToolPak (TPAK)The meter hanging solution• Kit includes, universal hanger clips (2), hook

& loop straps (2 lengths) and strong magnet• Combine components to meet most hanging

needsSee page 94 for compatibility chart

FlukeView Forms increases the power of yourFluke tool by enabling you to document, storeand analyze individual readings or series ofmeasurements, then convert them intoprofessional-looking documents.FlukeView Forms supports the following meters:• Fluke 180 Series Digital Multimeters

(Model FVF-SC2)• Fluke 87-IV & 89-IV Digital Multimeters

(Model FVF-SC1) • Fluke 53-II & 54-II Thermometers (Model

FVF-SC1)• Fluke 789 ProcessMeter™ (Model FVF-SC2)• Fluke 1653 (Model FVF-SC2 release 2.2 and

higher)• Fluke 1550B MegOhmMeter (model FVF-SC2)• Fluke 8845A/8846A Precision Multimeters

(Model FVF-SC4)

FlukeView® Forms Basic Owners of Fluke 180 series, 789 and 1550B,who do not need the full power of FlukeViewforms, can use FlukeView® Basic version.Transfer data points from your meter to your PCand use the two standard, non-customizableforms to display your readings in table orgraphical form. For a larger array of forms or touse FlukeView® Forms Designer to customizeyour forms, upgrade to FlukeView® Formsversion 3.0 with FVF-UG.

IR189USB IR to USB interface cable (included with FVF-SC2 and FVF-Basic) • For customers who want to upgrade from

their existing RS232 cable• Small adapter to connect the cable to the

189, 1653 or the 1550B is included. • CD-Rom with drivers for use with older

versions of FVF-SC1 included.

BP189 High Capacity Battery Enclosure(for Fluke 180 Series DMM)• Expand the battery life of your Fluke 187/189

up to 450 hours (over two weeks ofcontinuous use).

• Houses 4 ‘C’ cell batteries. • CAT III 1000 V, CAT IV 600 V Batteries and meter sold separately

All accessories have a one year warranty

Page 100: Fluke 2007

Other Accessories

98All accessories have a one year warranty

Lights

L200 Probe Light• Attaches to any Fluke test probe• Bright white LED• 120 hours of battery life

L205 Mini Hat LightRugged high-intensityXenon worklight• Attaches to a baseball cap• Includes a hat clip• Includes two AAA batteries• Waterproof

L206 Deluxe LED Hat Light (hard hat not included)Attach it to a hard hat, abaseball cap, or even apanel door for all the lightyou need.• 3 super bright white LEDs –

never burn out• Special hard-hat attachment included• 40-hour battery life• Includes three AAA batteries

L210 Probe Light +Probe Extender• Includes L200 Probe Light

and TP280 Test Probe Extenders• 20 cm probe extenders keep hands

away from live circuits• Extender fits between modular test probe

and test lead (total reach 30 cm)

High Voltage Probes

80K-6 and 80K-40A high voltage probe that allows a multimeter tomeasure up to 6,000V or40,000V respectively.Intended for low energy applications only

Stray Voltage Adapter

SV225 Stray Voltage Adapter (10-pack)Stray voltage can appear inelectrical installations, due tothe capacity between wires.This may result in erroneousreadings on high impedancemeters.

The SV225 solves this without compromising safety. • On energized wires, the meter will indicate

the real voltage. • On non-energized circuits the

meter will read close to zero(even if there are stray voltages).

• It can be used with all modernmeters with standard input spacing.

• Rated CAT III 1000 V, CAT IV 600 V

TL225 SureGrip™ Stray Voltage AdapterTest Lead Kit Kit includes: • SV225 Stray Voltage Eliminator • TL224 SureGrip™ Silicone

Test Lead Set (right tostraight)

• TP220 SureGrip™Test Probe Set

• C75 Accessory Case

MC6 MeterCleaner™ Wipes (6-pack)

MC50 MeterCleaner™ Wipes (50-pack)• Pre-moistened wipe removes dirt, oil and

grease• One wipe easily cleans one meter• Safe on rubber, plastic and for environment

(non-toxic)

Meter Cleaners

Page 101: Fluke 2007

A V IR Size Part nrin mm qty 1

125mA 250V 5x20 4822 070 31251

125mA (slow) 250V 6.35x32 166488

250mA (slow) 250V 6.35x32 166306

315 mA 1000V 10KA 6.35x32 2279339

440mA 1000V 10kA 10.3x34.9 943121

500mA 250V 1500A 5x20 838151

630mA 250V 1500A 5x20 740670

1A 600V 10kA 10.3x34.9 830828

1.25A 500V 6.35x32 2040349

3A 600V 10kA 10.3x38.1 475004

3.15A 500V 6.35x32 2030852

11A 1000V 17kA Replaced by 11A, 1000V, 20kA fuse; 803293

11A 1000V 20kA 10.3x38.1 803293

15A 600V 100kA 10.3x38.1 820829

20A 600V Replaced by 15A, 600V, 100kA fuse; part nr. 820829

See the back of your Fluke test tool or user manual for the fuses installed.For manuals check the Fluke website in the product section.For Fuse Replacement Guide check the Fluke website in the service section.

Each Fluke product is warranted to be free from defects inmaterial and workmanship under normal use and service,for the warranty period listed unless local law requires alonger period. The warranty period is listed in the orderinginformation section of the product specification and beginson the date of shipment. This warranty extends only to theoriginal buyer or end-user customer of a Fluke authorizedreseller, and does not apply to fuses, disposable batteriesor to any product which, in Fluke’s opinion, has beenmisused, altered, neglected or damaged by accident orabnormal conditions of operation or handling. Flukewarrants that software will operate substantially inaccordance with its functional specifications for 90 daysand that it has been properly recorded on non-defectivemedia. Fluke does not warrant that software will be errorfree or operate without interruption.

Lifetime WarrantyEach Fluke 20, 70, 80, 170 and 180 Series DMM purchasedafter October 1, 1996 will be free from defects in materialand workmanship for its lifetime. This warranty does notcover fuses, disposable batteries and damage from accident,neglect, contamination, misuse or abnormal conditions ofoperation or handling, including overvoltage failures causedby use outside the DMM’s specified rating, or normal wearand tear of mechanical components. This warranty coversthe original purchaser only and is not transferable. For ten years from the date of purchase, this warranty alsocovers the LCD. Thereafter, for the lifetime of the DMM,Fluke will replace the LCD for a fee based on then currentcomponent acquisition costs.

To establish original ownership and prove date of purchase,please complete and return the registration cardaccompanying the product.

Fluke will, at its discretion, repair at no charge, replace orrefund the purchase price of a defective product purchasedthrough a Fluke authorized sales outlet and at the applicableinternational price. Fluke reserves the right to charge forimportation costs of repair/replacement parts if productpurchased in one country is sent for repair elsewhere.

Send defective product with a description of the problemto the nearest Fluke Authorized Service Center, postageand insurance prepaid. Fluke will pay return transportationfor product repaired or replaced in-warranty. Before makingany non-warranty repair, Fluke will estimate cost andobtain authorization, then invoice you for repair and returntransportation.

THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHERWARRANTIES, SUCH AS FITNESS FOR A PARTICULARPURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOTLIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL ORCONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSSOF DATA, ARISING FROM ANY CAUSE OR THEORY.AUTHORIZED RESELLERS ARE NOT AUTHORIZED TOEXTEND ANY DIFFERENT WARRANTY ON FLUKE’S BEHALF.

Since some states do not allow the exclusion or limitationof an implied warranty or of incidental or consequentialdamages, this limitation of liability may not apply to you.

Product Warranty

Service

Fuse Replacement Information

Fuse and Warranty Information

99

Page 102: Fluke 2007

100

Fluke 114 17Fluke 115 17Fluke 116 17Fluke 117 17Fluke 117/322 Kit 13Fluke 123 70Fluke 123/S 70Fluke 124 70Fluke 124/S 70Fluke 1503 34Fluke 1507 34Fluke 1550B 31Fluke 1577 32Fluke 1587 32Fluke 1587ET 33Fluke 1587MDT 33Fluke 1587T 32Fluke 1623 35Fluke 1623 Kit 35Fluke 1625 35Fluke 1625 Kit 35Fluke 1630 36Fluke 1651 38Fluke 1652 38Fluke 1653 38Fluke 1735 63Fluke 1743 64Fluke 1744 64Fluke 1745 64Fluke 175 16Fluke 1760 57Fluke 1760 Basic 65Fluke 1760 Power 65Fluke 1760TR Basic 65Fluke 1760TR Power 65Fluke 177 16Fluke 179 16Fluke 179/EDA2 Kit 13Fluke 179/MAG2 Kit 13Fluke 187 14Fluke 189 14Fluke 189/FVF2 13Fluke 192B 67Fluke 192B/S 69Fluke 196B 67Fluke 196B/S 69Fluke 196C 67Fluke 196C/S 69Fluke 199B 67Fluke 199B/S 69Fluke 199C 67Fluke 199C/S 69Fluke 1AC II 26Fluke 1AC II 5PK 26Fluke 2042 28Fluke 2042T 28Fluke 27 18Fluke 321 23Fluke 322 23Fluke 333 22Fluke 334 22Fluke 335 22Fluke 336 22Fluke 337 22Fluke 345 58Fluke 360 24Fluke 43 Basic 59Fluke 43 Kit 59Fluke 434 61Fluke 434 Kit 61Fluke 435 61Fluke 43B 59Fluke 51 II 50Fluke 52 II 50

Fluke 53 II 50Fluke 54 II 50Fluke 561 49Fluke 572 47Fluke 572CF 47Fluke 574 47Fluke 574CF 47Fluke 576 47Fluke 576CF 47Fluke 61 48Fluke 62 48Fluke 6200-05 40Fluke 63 48Fluke 6500-05 40Fluke 66 48Fluke 68 48Fluke 700 Ex 85Fluke 705 79Fluke 707 79Fluke 707 Ex 85Fluke 712 77Fluke 714 77Fluke 715 79Fluke 717 78Fluke 717 1000G 78Fluke 717 100G 78Fluke 717 1500G 78Fluke 717 1G 78Fluke 717 3000G 78Fluke 717 300G 78Fluke 717 30G 78Fluke 717 5000G 78Fluke 717 500G 78Fluke 717 Ex 79Fluke 718 100G 78Fluke 718 1G 78Fluke 718 300G 78Fluke 718 30G 78Fluke 718 Ex 85Fluke 718 Ex 100G 78Fluke 718 Ex 30G 78Fluke 724 76Fluke 725 75Fluke 725 Ex 85Fluke 726 75Fluke 741B 74Fluke 743B 74Fluke 744 74Fluke 77 IV 18Fluke 771 80Fluke 787 81Fluke 789 81Fluke 83V 15Fluke 87V 15Fluke 87V/E 15Fluke 87V/E2 Kit 13Fluke 87V Ex 85Fluke 8845A 20Fluke 8845A/SU 20Fluke 8846A 20Fluke 8846A/SU 20Fluke 88V/A 19Fluke 902 22Fluke 9040 27Fluke 9062 27Fluke 971 45Fluke 975 43Fluke 975V 43Fluke 983 44Fluke CO-205 45Fluke CO-210 45Fluke CO-220 45Fluke T100 25Fluke T120 25

Fluke T140 25Fluke T50 25Fluke T5-1000 26Fluke T5-600 26Fluke Ti20 53Fluke Ti40-20 54Fluke Ti40FT-20 54Fluke Ti45-20 54Fluke Ti45FT-20 54Fluke Ti50-20 54Fluke Ti50FT-20 54Fluke Ti55-20 54Fluke Ti55FT-20 54Fluke VR101 62Fluke VR101S 62103232 55104543 55700HTH 82700HTP 82700ILF 82700LTP 82700P00 82700P01 82700P01 Ex 82700P02 82700P03 82700P04 82700P05 82700P05 Ex 82700P06 82700P06 Ex 82700P07 82700P08 82700P09 82700P09 Ex 82700P22 82700P23 82700P24 82700P24 Ex 82700P27 82700P27 Ex 82700P29 82700P29 Ex 82700P30 82700P31 82700PA3 82700PA4 82700PA4 Ex 82700PA5 82700PA6 82700PCK 82700PD2 82700PD3 82700PD4 82700PD5 82700PD6 82700PD7 82700PRV 82700PTP 82700PV3 82700PV4 82700SW 74700TC1 93700TC2 9380AK 9280BK 9280CJ-M 9380CK-M 9380i-110s 9180K-40 9880K-6 9880PJ-1 9280PJ-9 9280PJ-EXT 93

80PK-1 9280PK-11 9280PK-22 9280PK-24 9280PK-25 9280PK-26 9280PK-27 9280PK-3A 9280PK-8 9280PK-9 9280PK-EXT 9380PR-60 9380PT-EXT 9380T-150U 9280TK 92884X-512M 2090i-610s 96975CK 43975TPK 43975VP 43AC220 89AC280 89AC283 89AC285 89AC72 89AC87 89AC89 89ACC-T5-Kit 89AN5 47AS200-G 71AS200-R 71BDST1 41BDST2 41BE9005 82BP120MH 71BP130 71BP189 97BP190 71BP7235 82BP880 96BP881 96BP980 87C10 95C100 95C101 95C120 95C125 94C12A 94C1600 95C190 95C195 94C20 95C23 94C25 94C33 94C43 94C435 95C50 94C510 95C520A 95C550 94C570 94C70Y 95C75 94C781 94C789 94C800 95C90 94DMS 41DP120 71EI-1623 35EI-1625 35EI-162BN 35ES-162P3 35

ES-162P4 35ES165X (1653) 38EXTL100-02 41FOC 97FOM 97FOS 1300 97FOS 850 97FVF-Basic 97FVF-SC1 50FVF-SC2 97FVF-UG 20GPS430 61H3 95H5 95H6 95H80M 95H900 87i1000s 90i1010 91i1010 Kit 91i200 90i2000flex 90i200s 90i30 91i3000flex 90i3000s 90i30s 91i400 90i400s 90i410 91i410 Kit 91i430-flex-4pk 61i5s 90i5sPQ3 91IR189USB 97L200 98L205 98L206 98L210 98L215 89LPAK 97LVD1 26LVD2 26MBX 300 Poleset 64MBX Clamp 1A/10A 63MBX Clamp 1A/10A 64MBX Clamp 20A/200A 64MBX Clamp 5A/50A 64MC50 98MC6 98MTC1363 (UK) 38MTC77 (Europa) 38OC4USB 71PAC91 71PASS 41PM9080 71PM9081 71PM9082 71PM9086 71PM9090 71PM9091 71PM9092 71PM9093 71PM9094 71PV350 96RPM80 96RS200 71SCC120 70SCC128 96SCC190 69SCC198 96SP1000-02 41SP-Scan-15 41SV225 98

SW43W 61SW90W 69, 70T5-H5-1AC Kit 26Ti20-CC 53Ti20-RBP 53Ti-SBC 55Ti-SBP 55Ti20-Visor 53TL220 88TL221 88TL222 88TL223 88TL224 88TL225 98TL238 88TL27 88TL28A 96TL2X4W-KC 20TL2X4W-PT 20TL40 87TL71 88TL75 88TL76 88TL80A 87TL81A 87TL82 96TL910 87TL930 87TL932 87TL935 87TL940 87TL950 87TL960 87TL970 87TLK-220 88TLK-225 88TLK281 96TLK282 96TLK290 89TLK291 89TP1 89TP2 89TP220 89TP38 89TP4 89TP40 96TP74 89TP80 89TP81 96TP82 96TP84 96TP88 96TP912 87TP920 87TPAK 97TPS Clamp 10A/1A 65TPS Clamp 200A/20A 65TPS Clamp 50A/5A 65TPS FLEX 18 65TPS FLEX 24 65TPS FLEX 36 65TPS Shunt 20MA 65TPS Shunt 5A 65TPS Voltprobe 1KV 65TPS Voltprobe 10V 65TPS Voltprobe 100V 65TPS Voltprobe 400V 65TPS Voltprobe 600V 65TPS Voltprobe 750V 65VPS100/200 series 71VPS40 71

Model Page

Product Quick Find List

Model Page Model Page Model Page Model Page Model Page

Page 103: Fluke 2007

In addition to the products featured in this Test ToolsCatalog, Fluke also offers a variety of other products,an overview of which is shown in the followingcatalogs.

Fluke PrecisionMeasurement products

Total Solutions in PrecisionMeasurementA variety of products covering DC/LFElectrical Calibration, Power Calibration,Calibration Software, Pressure Calibration,

Time and Frequency, Temperature and Humidity Calibrationincluding Hart Scientific, as well as Data Acquisition andGeneral Purpose Test products like arbitrary waveformgenerators and VXI products.

To get a copy, please click “Request a catalog” on yourlocal Fluke web site.

Fluke Networks products

Network SuperVision Solutions forthe Copper and Fiber CablingInfrastructure. The most comprehensive line of premisesnetwork testing tools for the inspection,verification, certification anddocumentation of copper and fiber opticcabling systems.

Networks Supervision Solutionsfor the testing, monitoring andanalysis of enterprise networks.Our Distributed Vision Solutions enablecentralized analysis with deep and widevisibility of what’s happeningthroughout your network in all areassuch as VoIP, Wireless and WAN.

To get a copy, please contact the local Fluke Networkssales organization: www.flukenetworks.com/contact.

Other catalogs from Fluke

Fluke. Keeping your worldup and running.TM

101