5
FLUID HANDLING: TC Series Filter Cart This heavy-duty, high capacity portable system is capable of removing particles and/or free water from industrial oils and can be configured to meet the needs of almost any specific application.

FLUID HANDLING - descase-europe.com · • Pre and post filter sample ports ... • 2,2 kW 3x230v 50 Hz 1400 rpms ... Micron Rating Beta 200 @ 3µm Beta 200 @ 6µm

Embed Size (px)

Citation preview

FLUID HANDLING: TC Series Filter CartThis heavy-duty, high capacity portable system is capable of removing particles and/or free water from industrial oils and can be configured to meet the needs of almost any specific application.

The OverviewThe TC Filter Cart:

Where It’s Used• Decontaminating systems• Flushing new or repaired systems• Dispensing oil• Pre-filtering new oil• Evacuating used oil• Topping off reservoirs• Flushing systems• Collecting oil samples for analysis

What Can I Customize?• Color• Micron ratio of filters• Power configurations

What Is Standard?• Automatic pump pressure relief• Dual-stage filtration• Pump inlet strainer• Pre and post filter sample ports• Manual bypass• Heavy-duty cart with oil catch pan• Industrial powder-coated paint• One-year warranty

Technical Data:

Pump Type: • Gear PumpElectric motor:• 2,2 kW 230v 50 Hz 1400 rpms• 2,2 kW 3x230v 50 Hz 1400 rpms• 2,2 kW 3x400v 50 Hz 1400 rpmsPermissible flow rate:• 70 lpm maximumOperating pressure:• 6 bar maximumViscosity range:• 10-460 cSt (60 - 2270 SSU)Permissible operating fluid:• Mineral oil (others on request)Permitted fluid temperature range:• -10°C to 60°CPermitted Ambient temperature:• -10°C to 40°CSeals:• NBRSuction Strainer:• 250µmProtection class:• IP 54Length of power cable:• 5 metersLength of hoses:• 5 metersHose connections:• Suction hose 1-1/4" camlock• Pressure hose 1-1/4" camlockWeight when empty:• ≈ 170 kgEquipment:• Suction Gauge - Visual• Pressure Gauge - Visual• Differential Pressure Gauge - Visual• Pressure Switch (6,5 bar) - Electrical

The Features15

17

18

19

2014

Number Description

1 Lifting Eye

2 First Filter Canister

3 Pressure Gauge

4 Sample Port

5 High Pressure Switch

6 First Canister Differential Gauge

7 First Canister Drain

8 Second Canister Drain

9 Second Canister Differential Gauge

10 Outlet Hose

11 Inlet Hose

12 Second Filter Canister

13 Filter Canister Vent Valve

14 Inlet Strainer

15 Power Cord

16 Power Switch

17 Motor

18 Pump

19 Bypass Valve

20 Pump Relief Adustment Screw

D

C

B

A

B

C

D

12345678

8 7 6 5 4 3 2 1

PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFDES-CASE CORPORATION. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFDES-CASE CORPORATION IS PROHIBITED.

SHEET 3 OF 3

ENG APPR.

CHECKED

DRAWN

DATENAME

DIMENSIONS ARE IN INCHES

FINISH

MATERIAL

REV.

BDWG. NO.SIZE

SCALE: 1:8

B10007997

2 Wheel TC-Cart Example----

--

--

-- --

-- --

12

2

8

79

6

3

1

11

10

4

13

5

Number Description

1 Lifting Eye

2 First Filter Canister

3 Pressure Gauge

4 Sample Port

5 High Pressure Switch

6 First Canister Differential Gauge

7 First Canister Drain

8 Second Canister Drain

9 Second Canister Differential Gauge

10 Outlet Hose

11 Inlet Hose

12 Second Filter Canister

13 Filter Canister Vent Valve

14 Inlet Strainer

15 Power Cord

16 Power Switch

17 Motor

18 Pump

19 Bypass Valve

20 Pump Relief Adustment Screw

D

C

B

A

B

C

D

12345678

8 7 6 5 4 3 2 1

PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFDES-CASE CORPORATION. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFDES-CASE CORPORATION IS PROHIBITED.

SHEET 3 OF 3

ENG APPR.

CHECKED

DRAWN

DATENAME

DIMENSIONS ARE IN INCHES

FINISH

MATERIAL

REV.

BDWG. NO.SIZE

SCALE: 1:8

B10007997

2 Wheel TC-Cart Example----

--

--

-- --

-- --

mm

mm

mm mm

mm

mm

mm

mmmm

mm

mm

mm

mm

mm

Model Code TC Series Filter Cart

Pump/Motor Combinations [Box 1]

70H

70M

70K

Manual Filter Bypass [Box 6]Code Description B Filter Bypass

Sample Valves [Box 7]Code Description 2 Standard Minimess

ETCBox 1 Box 2 Box 3 Box 4 Box 5 Box 6 Box 7 Box 8 Box 9 Box 10

Drain & Fill Connector Type [Box 2]Code Description

Drain & Fill Sizing [Box 3]6 Drain: 1" hose & 1-1/4" connection

Fill: 1" hose & 1-1/4" connection

Filter A [Box 4]/Filter B [Box 5]Code Description

2A 3-micron Particulate Filter

2B 6-micron Particulate Filter

2C 12-micron Particulate Filter

2D 25-micron Particulate Filter

2J Water Filter

Cord [Box 8]Code Description

C 5 m cord

Strainer [Box 9]Code DescriptionS Strainer

Custom Colors [Box 10]Code1

2

3

4

5

6

Description

Brushed Aluminum

Black

White

Blue

Red

Yellow

Replace Your Elements

Part No.

E04-618-3UM

E04-618-6UM

E04-618-12UM

E04-618-25UM

E04-618-WR

Micron Rating Beta 200 @ 3µm

Beta 200 @ 6µm

Beta 200 @ 12µm

Beta 200 @ 25µm

Water Removal

C Camlock

Code Description

70 lpm/2,2 kW, 230 V, 50 Hz, 1400 rpms

70 lpm/ 2,2 kW, 3x230V, 50 Hz, 1400 rpms

70 lpm/ 2,2 kW, 3x400V, 50 Hz, 1400 rpms

FLUID HANDLING: The Entire Des-Case LineWe offer a full range of fluid handling and filtration products in Portable Filtration, Dedicated Filtration, Water Removal, Lubricant Storage & Filtration, Filter Elements, and Adapter Kits to suit your needs.

Des-Case Europe | Paseo Gazteluzahar 16 | E20305 - Irun (Guipuzkoa), SpainDirect: +34 943.561.124 | Fax: +34 943.633.054 | descase.eu

© 2018 Des-Case Corporation. All rights reserved. ® Des-Case is a registered trademark of Des-Case Corporation.