Upload
ngothien
View
218
Download
1
Embed Size (px)
Citation preview
FLUID HANDLING: TC Series Filter CartThis heavy-duty, high capacity portable system is capable of removing particles and/or free water from industrial oils and can be configured to meet the needs of almost any specific application.
The OverviewThe TC Filter Cart:
Where It’s Used• Decontaminating systems• Flushing new or repaired systems• Dispensing oil• Pre-filtering new oil• Evacuating used oil• Topping off reservoirs• Flushing systems• Collecting oil samples for analysis
What Can I Customize?• Color• Micron ratio of filters• Power configurations
What Is Standard?• Automatic pump pressure relief• Dual-stage filtration• Pump inlet strainer• Pre and post filter sample ports• Manual bypass• Heavy-duty cart with oil catch pan• Industrial powder-coated paint• One-year warranty
Technical Data:
Pump Type: • Gear PumpElectric motor:• 2,2 kW 230v 50 Hz 1400 rpms• 2,2 kW 3x230v 50 Hz 1400 rpms• 2,2 kW 3x400v 50 Hz 1400 rpmsPermissible flow rate:• 70 lpm maximumOperating pressure:• 6 bar maximumViscosity range:• 10-460 cSt (60 - 2270 SSU)Permissible operating fluid:• Mineral oil (others on request)Permitted fluid temperature range:• -10°C to 60°CPermitted Ambient temperature:• -10°C to 40°CSeals:• NBRSuction Strainer:• 250µmProtection class:• IP 54Length of power cable:• 5 metersLength of hoses:• 5 metersHose connections:• Suction hose 1-1/4" camlock• Pressure hose 1-1/4" camlockWeight when empty:• ≈ 170 kgEquipment:• Suction Gauge - Visual• Pressure Gauge - Visual• Differential Pressure Gauge - Visual• Pressure Switch (6,5 bar) - Electrical
The Features15
17
18
19
2014
Number Description
1 Lifting Eye
2 First Filter Canister
3 Pressure Gauge
4 Sample Port
5 High Pressure Switch
6 First Canister Differential Gauge
7 First Canister Drain
8 Second Canister Drain
9 Second Canister Differential Gauge
10 Outlet Hose
11 Inlet Hose
12 Second Filter Canister
13 Filter Canister Vent Valve
14 Inlet Strainer
15 Power Cord
16 Power Switch
17 Motor
18 Pump
19 Bypass Valve
20 Pump Relief Adustment Screw
D
C
B
A
B
C
D
12345678
8 7 6 5 4 3 2 1
PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFDES-CASE CORPORATION. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFDES-CASE CORPORATION IS PROHIBITED.
SHEET 3 OF 3
ENG APPR.
CHECKED
DRAWN
DATENAME
DIMENSIONS ARE IN INCHES
FINISH
MATERIAL
REV.
BDWG. NO.SIZE
SCALE: 1:8
B10007997
2 Wheel TC-Cart Example----
--
--
-- --
-- --
12
2
8
79
6
3
1
11
10
4
13
5
Number Description
1 Lifting Eye
2 First Filter Canister
3 Pressure Gauge
4 Sample Port
5 High Pressure Switch
6 First Canister Differential Gauge
7 First Canister Drain
8 Second Canister Drain
9 Second Canister Differential Gauge
10 Outlet Hose
11 Inlet Hose
12 Second Filter Canister
13 Filter Canister Vent Valve
14 Inlet Strainer
15 Power Cord
16 Power Switch
17 Motor
18 Pump
19 Bypass Valve
20 Pump Relief Adustment Screw
D
C
B
A
B
C
D
12345678
8 7 6 5 4 3 2 1
PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFDES-CASE CORPORATION. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFDES-CASE CORPORATION IS PROHIBITED.
SHEET 3 OF 3
ENG APPR.
CHECKED
DRAWN
DATENAME
DIMENSIONS ARE IN INCHES
FINISH
MATERIAL
REV.
BDWG. NO.SIZE
SCALE: 1:8
B10007997
2 Wheel TC-Cart Example----
--
--
-- --
-- --
mm
mm
mm mm
mm
mm
mm
mmmm
mm
mm
mm
mm
mm
Model Code TC Series Filter Cart
Pump/Motor Combinations [Box 1]
70H
70M
70K
Manual Filter Bypass [Box 6]Code Description B Filter Bypass
Sample Valves [Box 7]Code Description 2 Standard Minimess
ETCBox 1 Box 2 Box 3 Box 4 Box 5 Box 6 Box 7 Box 8 Box 9 Box 10
Drain & Fill Connector Type [Box 2]Code Description
Drain & Fill Sizing [Box 3]6 Drain: 1" hose & 1-1/4" connection
Fill: 1" hose & 1-1/4" connection
Filter A [Box 4]/Filter B [Box 5]Code Description
2A 3-micron Particulate Filter
2B 6-micron Particulate Filter
2C 12-micron Particulate Filter
2D 25-micron Particulate Filter
2J Water Filter
Cord [Box 8]Code Description
C 5 m cord
Strainer [Box 9]Code DescriptionS Strainer
Custom Colors [Box 10]Code1
2
3
4
5
6
Description
Brushed Aluminum
Black
White
Blue
Red
Yellow
Replace Your Elements
Part No.
E04-618-3UM
E04-618-6UM
E04-618-12UM
E04-618-25UM
E04-618-WR
Micron Rating Beta 200 @ 3µm
Beta 200 @ 6µm
Beta 200 @ 12µm
Beta 200 @ 25µm
Water Removal
C Camlock
Code Description
70 lpm/2,2 kW, 230 V, 50 Hz, 1400 rpms
70 lpm/ 2,2 kW, 3x230V, 50 Hz, 1400 rpms
70 lpm/ 2,2 kW, 3x400V, 50 Hz, 1400 rpms
FLUID HANDLING: The Entire Des-Case LineWe offer a full range of fluid handling and filtration products in Portable Filtration, Dedicated Filtration, Water Removal, Lubricant Storage & Filtration, Filter Elements, and Adapter Kits to suit your needs.
Des-Case Europe | Paseo Gazteluzahar 16 | E20305 - Irun (Guipuzkoa), SpainDirect: +34 943.561.124 | Fax: +34 943.633.054 | descase.eu
© 2018 Des-Case Corporation. All rights reserved. ® Des-Case is a registered trademark of Des-Case Corporation.