• Dual peristaltic pump technology with integrated suction
• Defi cit accuracy within +/- 50mL
• Preset defi cits per AAGL guidelines
• System won’t leave setup screen until all components are in place
• System starts warning users at 75% of set defi cit limit
• System warns users when supply bag is low and waste bag is full
• Can hang a bag while the system is running
• Defi cit set from 100ml-2,500Ml in 50ml increments
• Pressure can be set from 40-120mmHg in 5mmHg increments
Simplifi ed setup and operation
Advanced technology to increase clinical confi dence
Streamlined workfl ow for the entire OR team
Fluent® Fluid Management SystemThe Fluent system transforms the fl uid management experience.
MISC-05433-001 ©2018 Hologic, Inc. Hologic, FloPak, Fluent, In-FloPak, MyoSure, Out-FloPak, The Science of Sure, and associated logos are trademarks or registered trademarks of Hologic, Inc. and/or its subsidiaries in the United States and/or other countries.
Disposable Procedure Kit Specifi cations
Components In-FloPak, Out-FloPak, waste bag, tissue sock,
Dimensions (single box) 17.24” (L) X 15” (W) X 3.45” (D)
Fluent Mechanics
System Weight 88.2 lbs(40Kg)
System size dimensions 24.50” (W) x 60.36” (H) x 22.50” (D)
Max load cell capacity 6.3Kg
Figure 2: The rear of the Fluent Fluid Management System Console
Figure 1: The front of the Fluent Fluid Management System Console with corresponding parts attached.
Electrical Requirements
Fuse designation T5AH, 250 V fuses
Power consumption 250W
Mains voltage range 100-240 VAC
Supply Frequency range 50-60Hz
General Operation Conditions
Temperature Range 15-30°C/ 58-85°F
Storage and transport conditions -10-60°C/14-140°F
Relative humidity 20-80% (non-condensing)
1 Fluid Bag Hooks Location to hang up to 6L of fl uid
2 Fluid Bag Pole Contains two IV Hooks to hang up to 6L fl uid
3 Touchscreen Monitor Allows confi guring, adjusting and monitoring the status
4 Fluent In-FloPak Receptacle Location to insert the Fluent In-FloPak
5 Fluent In-FloPak Receptacle Location to insert the Fluent Out-FloPak
6 MyoSure Tissue Removal Device (TRD) Connector
Location to connect the MyoSure TRD drive cable to the Fluent Fluid Management System
7 Foot Pedal Connector Location to connect the MyoSure Foot Pedal cord to the Fluent Fluid Management System
8 Waste Bag Hanger Location to hang the Waste Bag
9 Waste Bag Waste Bag
10 Wheels Enables movement and positioning or the Fluent Management System
11 Wheel Locks Prevents movement and positioning of the wheels
12 Handle Grasp to move and position the SystemLocation to wrap the Power Cod when not in use
13 On/O� Switch Turns the System On (I) and O� (0)
14 Power Port Location to connect the Power Cord to the System
15 Equipotential Plug Connector used to electrically bone the system to another conductive material, or ground the system to a safety ground.
16 Storage Basket mount points Location to hang the Storage Basket