FLOWSIC100

GAS FLOW MEASURING INSTRUMENTS

Page 2: FLOWSIC100, Product data sheet · GAS FLOW MEASURING INSTRUMENTS VOLUME FLOW MEASURING DEVICES FOR CON-TINUOUS EMISSION MONITORING Ordering information Type Part no. FLOWSIC100 On

ABCDEF

HIJKLMNOPQRST

FLOWSIC100GAS FLOW MEASURING INSTRUMENTS

VOLUME FLOW MEASURING DEVICES FOR CON-TINUOUS EMISSION MONITORING

Ordering information

Type Part no.

FLOWSIC100 On request

In accordance with Article 2 (4), this product does not fall within the scope of RoHS directive 2011/65/EU and is also not de-signed for use in products which fall within the scope of this directive. You can find additional information in the product infor-mation.

The exact device specifications and performance data of the product may deviate from the information provided here, anddepend on the application in which the product is being used and the relevant customer specifications.

Our regional sales organization will help you to select the optimum device configuration.

Other models and accessories www.sick.com/FLOWSIC100

Product descriptionThe product family FLOWSIC100 was designed for emission monitoring tasks. The "H" versionsare suitable for stacks with large diameters and applications with high dust content. The "M"versions are especially suited for stacks with medium diameter. The ultrasonic transducers ofthe "PR" probe type are mounted with fixed path length on one sender/receiver unit (measur-ing probe). The "AC" versions have an innovative internal cooling and are suitable for gas tem-peratures up to 450 °C. The purged "Px" versions are used for gases with high concentrations ofsticky or wet dust.Rugged titanium transducers are standard and suitable under difficult conditions. The measur-ing system consists of 2 sender/receiver units or a measuring probe and a MCU control unit. TheMCU is used for input and output of signals, for calculation of volume flow to reference conditions(standardization) as well as user-friendly LCD interface.

At a glance• Rugged titanium converters for long service life• Corrosion-resistant material for use with aggressive gases (option)• Integrated measurement via duct diameter for types H, M, and S• Probe version PR for cost-saving, single-sided installation in duct• Automated operational check with zero and reference point test

Your benefits• Reliable flow measurement for ducts with small up to very large diameters• High durability of the device• No purge air required for applications with gas temperatures up to 260 °C• Minimum operating and maintenance costs• Accurate measuring results under difficult measuring conditions• Measurement without pressure loss, therefore no influences on the process• User-friendly operation via SOPAS ET software• Reliable function monitoring due to enhanced diagnosis

15267

certified 14181

certified

2 FLOW MEASUREMENT TECHNOLOGY | SICK Product data sheet | 2020-08-17 08:48:40

Subject to change without notice

Page 3: FLOWSIC100, Product data sheet · GAS FLOW MEASURING INSTRUMENTS VOLUME FLOW MEASURING DEVICES FOR CON-TINUOUS EMISSION MONITORING Ordering information Type Part no. FLOWSIC100 On

FLOWSIC100GAS FLOW MEASURING INSTRUMENTS

Fields of application• Continuous emission measurement during power generation• Emission monitoring in waste incineration plants• Emission measurement in the processing industry (cement, iron and steel, glass)• Emission monitoring in the chemical and hydrocarbon processing (HPI) industry• Emission monitoring in the paper and textiles industry• Flow measurements and process control in e. g., heating and ventilation systems

Detailed technical data

FLOWSIC100 systemMeasured values Volumetric flow a. c., volumetric flow s. c., gas velocity, sound velocity, gas temperature

Performance-tested measurands Gas velocity

Measurement principle Ultrasonic transit time difference measurement

Measuring ranges

Gas velocity 0 ... ± 40 m/s

Certified measuring ranges

Gas velocity 0 ... 20 m/s / 0 ... 40 m/s

Repeatability For v < 2 m/s: ± 0.02 m/sFor v > 2 m/s: ± 1 %

Accuracy

± 0.1 m/sDepending on application

Diagnostics functions Automatic check cycle for zero and span pointExtended device diagnosis via SOPAS ET software

Ambient temperature

–40 °C ... +60 °C

Storage temperature –40 °C ... +70 °C

Conformities 2001/80/EC (13. BImSchV)2000/76/EC (17. BImSchV)27. BImSchV30. BImSchVTA-Luft (Prevention of Air Pollution)EN 15267EN 14181EN 16911-2MCERTSGOST

Electrical safety CE

FLOWSIC100 MGas temperature

–40 °C ... +260 °C

Operating pressure –100 hPa ... 100 hPa

Nominal pipe size

0.15 m ... 3.4 m

Dust load ≤ 1 g/m³Depending on measuring path and gas temperature

Enclosure rating

IP65 MCU

2020-08-17 08:48:40 | Product data sheet

Subject to change without notice

FLOW MEASUREMENT TECHNOLOGY | SICK 3

Page 4: FLOWSIC100, Product data sheet · GAS FLOW MEASURING INSTRUMENTS VOLUME FLOW MEASURING DEVICES FOR CON-TINUOUS EMISSION MONITORING Ordering information Type Part no. FLOWSIC100 On

ABCDEF

HIJKLMNOPQRST

FLOWSIC100GAS FLOW MEASURING INSTRUMENTS

Mounting Installation angle 45° ... 60°

Electrical connection

Power consumption ≤ 40 W

System components 2 x FLSE100-M sender/receiver unit1 x MCU-N control unit1 x connection unit2 x Connection cable2 x flange with tube

FLOWSIC100 HGas temperature

–40 °C ... +260 °C

Operating pressure –100 hPa ... 100 hPa

Nominal pipe size

1.4 m ... 13 m

Dust load ≤ 100 g/m³Depending on measuring path and gas temperature; for dry, non-sticky dust

Enclosure rating

IP65 MCU

Mounting Installation angle 45° ... 60°

Electrical connection

Power consumption ≤ 40 W

System components 2 x FLSE100-H sender/receiver unit1 x MCU-N control unit1 x connection unit2 x Connection cable2 x flange with tube

FLOWSIC100 PRGas temperature

–40 °C ... +260 °C

Operating pressure –100 hPa ... 100 hPa

Nominal pipe size

≥ 0.4 m

Dust load ≤ 1 g/m³Depending on measuring path and gas temperature

Enclosure rating

IP65 MCU

Mounting Installation angle 45°

Electrical connection

Power consumption ≤ 40 W

System components 1 x FLSE100-PR sender/receiver unit1 x MCU-N control unit1 x Connection cable1 x flange with tube

FLOWSIC100 SGas temperature

–40 °C ... +150 °C

Operating pressure –100 hPa ... 100 hPa

4 FLOW MEASUREMENT TECHNOLOGY | SICK Product data sheet | 2020-08-17 08:48:40

Subject to change without notice

Page 5: FLOWSIC100, Product data sheet · GAS FLOW MEASURING INSTRUMENTS VOLUME FLOW MEASURING DEVICES FOR CON-TINUOUS EMISSION MONITORING Ordering information Type Part no. FLOWSIC100 On

FLOWSIC100GAS FLOW MEASURING INSTRUMENTS

Nominal pipe size

0.15 m ... 1.7 m

Dust load ≤ 1 g/m³Depending on measuring path and gas temperature

Enclosure rating

IP65 MCU

Mounting Installation angle 45° ... 60°

Electrical connection

Power consumption ≤ 40 W

System components 2 x FLSE100-S sender/receiver unit1 x MCU-N control unit2 x Connection cable2 x flange with tube

FLOWSIC100 M-AC

Gas temperature

–40 °C ... +450 °C

Operating pressure –100 hPa ... 100 hPa

Nominal pipe size

0.15 m ... 3.4 m

Dust load ≤ 1 g/m³Depending on measuring path and gas temperature

Mounting Installation angle 45° ... 60°

Electrical connection

Power consumption ≤ 75 W

System components 2 x FLSE100-MAC sender/receiver unit1 x MCU-P control unit1 x connection unit2 x Connection cable2 x purge air hose2 x flange with tube

FLOWSIC100 H-AC

Gas temperature

–40 °C ... +450 °C

Operating pressure –100 hPa ... 100 hPa

Nominal pipe size

1.4 m ... 11.3 m

Dust load ≤ 100 g/m³Depending on measuring path and gas temperature; for dry, non-sticky dust

Mounting Installation angle 45° ... 60°

Electrical connection

Power consumption ≤ 75 W

System components 2 x FLSE100-HAC sender/receiver unit1 x MCU-P control unit1 x connection unit2 x Connection cable2 x purge air hose2 x flange with tube

2020-08-17 08:48:40 | Product data sheet

Subject to change without notice

FLOW MEASUREMENT TECHNOLOGY | SICK 5

Page 6: FLOWSIC100, Product data sheet · GAS FLOW MEASURING INSTRUMENTS VOLUME FLOW MEASURING DEVICES FOR CON-TINUOUS EMISSION MONITORING Ordering information Type Part no. FLOWSIC100 On

ABCDEF

HIJKLMNOPQRST

FLOWSIC100GAS FLOW MEASURING INSTRUMENTS

FLOWSIC100 PM

Gas temperature

–40 °C ... +450 °C

Operating pressure –100 hPa ... 100 hPa

Nominal pipe size

0.35 m ... 2.5 m

Dust load ≤ 1 g/m³Depending on measuring path and gas temperature

Enclosure rating

IP65 MCU

Mounting Installation angle 45° ... 60°

Electrical connection

Power consumption ≤ 40 W

System components 2 x FLSE100-PM sender/receiver unit1 x MCU-N control unit1 x connection unit2 x Connection cable2 x flange with tube2 x purge air hose1 x purge air unit

FLOWSIC100 PH

Gas temperature

–40 °C ... +450 °C

Operating pressure –100 hPa ... 100 hPa

Nominal pipe size

0.7 m ... 8.7 m

Dust load ≤ 100 g/m³Depending on measuring path and gas temperature

Enclosure rating

IP65 MCU

Mounting Installation angle 45° ... 60°

Electrical connection

Power consumption ≤ 40 W

System components 2 x FLSE100-PH sender/receiver unit1 x MCU-N control unit1 x connection unit2 x Connection cable2 x flange with tube2 x purge air hose1 x purge air unit

FLOWSIC100 PH-S

Gas temperature

–40 °C ... +450 °C

Operating pressure –100 hPa ... 100 hPa

Nominal pipe size

1.4 m ... 11.3 m

Dust load ≤ 100 g/m³

6 FLOW MEASUREMENT TECHNOLOGY | SICK Product data sheet | 2020-08-17 08:48:40

Subject to change without notice

Page 7: FLOWSIC100, Product data sheet · GAS FLOW MEASURING INSTRUMENTS VOLUME FLOW MEASURING DEVICES FOR CON-TINUOUS EMISSION MONITORING Ordering information Type Part no. FLOWSIC100 On

FLOWSIC100GAS FLOW MEASURING INSTRUMENTS

Depending on measuring path and gas temperature

Enclosure rating

IP65 MCU

Mounting Installation angle 45° ... 60°

Electrical connection

Power consumption ≤ 40 W

System components 2 x FLSE100-PHS sender/receiver unit1 x MCU-N control unit1 x connection unit2 x Connection cable2 x flange with tube2 x purge air hose1 x purge air unit

MCU-N control unitDescription Compulsory control and evaluation unit for volume flow measuring devices without internal

cooling

Ambient temperature

–40 °C ... +60 °C

Enclosure rating

IP65

Analog outputs 1 output:0/2/4 ... 20 mA, + 750 ΩElectrically isolated, up to five outputs when add-on modules are used (option)

Analog inputs 2 inputs:0 ... 20 mAUp to four outputs when using additional modules (option)

Digital outputs 5 relay outputs (change-over contacts), potential-free:+ 48 V, 1 ASafety extra-low voltage; for status signals "operation/malfunction", "limit value", "warning","maintenance" and "check cycle"

Digital inputs 4 potential-free contacts

USB ✔

Function Connection to SOPAS ET software

Serial ✔

Type of fieldbus integration RS-232RS-485

Function Connection to SOPAS ET softwareInternal system bus

Ethernet ✔

Type of fieldbus integration Via optional interface module

Modbus ✔

Type of fieldbus integration ASCII RS-485 (via optional interface module)RTU RS-485 (via optional interface module)TCP (via optional interface module)

PROFIBUS DP ✔

Type of fieldbus integration Via optional interface module

Indication LC display (option)Status LEDs: “Power,” “Failure,” and “Maintenance request”

Operation Via LC-display (option) or software SOPAS ET

Dimensions (W x H x D) 210 mm x 340 mm x 120 mm

2020-08-17 08:48:40 | Product data sheet

Subject to change without notice

FLOW MEASUREMENT TECHNOLOGY | SICK 7

Page 8: FLOWSIC100, Product data sheet · GAS FLOW MEASURING INSTRUMENTS VOLUME FLOW MEASURING DEVICES FOR CON-TINUOUS EMISSION MONITORING Ordering information Type Part no. FLOWSIC100 On

ABCDEF

HIJKLMNOPQRST

FLOWSIC100GAS FLOW MEASURING INSTRUMENTS

Weight ≤ 3.7 kg

Electrical connection

Voltage 90 ... 250 V

Version with 24 V DC available as an option

Frequency 47 ... 63 Hz

Power consumption ≤ 15 W

Options Interface module(s)I/O module(s)LC display19″-type

MCU-P control unitDescription Compulsory control and evaluation unit with integrated cooling air unit, for volume flow mea-

suring devices with internal cooling

Ambient temperature

–40 °C ... +45 °CIntake temperatures for purge air

Enclosure rating

IP54

Analog outputs 1 output:0/2/4 ... 20 mA, + 750 ΩElectrically isolated, up to five outputs when add-on modules are used (option)

Analog inputs 2 inputs:0 ... 20 mANot electrically isolated; additional inputs if using I/O modules (option)

Digital outputs 5 relay outputs (change-over contacts), potential-free:+ 48 V, 1 ASafety extra-low voltage; for status signals "operation/malfunction", "limit value", "warning","maintenance" and "check cycle"

Digital inputs 4 potential-free contacts

USB ✔

Function Connection to SOPAS ET software

Serial ✔

Type of fieldbus integration RS-232RS-485

Function Connection to SOPAS ET softwareInternal system bus

Ethernet ✔

Type of fieldbus integration Via optional interface module

Modbus ✔

Type of fieldbus integration ASCII RS-485 (via optional interface module)RTU RS-485 (via optional interface module)TCP (via optional interface module)

PROFIBUS DP ✔

Type of fieldbus integration Via optional interface module

Indication LC display (option)Status LEDs: “Power,” “Failure,” and “Maintenance request”

Operation Via LC-display (option) or software SOPAS ET

Dimensions (W x H x D) 300 mm x 455 mm x 220 mm

Weight ≤ 13.5 kg

8 FLOW MEASUREMENT TECHNOLOGY | SICK Product data sheet | 2020-08-17 08:48:40

Subject to change without notice

Page 9: FLOWSIC100, Product data sheet · GAS FLOW MEASURING INSTRUMENTS VOLUME FLOW MEASURING DEVICES FOR CON-TINUOUS EMISSION MONITORING Ordering information Type Part no. FLOWSIC100 On

FLOWSIC100GAS FLOW MEASURING INSTRUMENTS

Electrical connection

Voltage 90 ... 250 V

Version with 24 V DC available as an option

Frequency 47 ... 63 Hz

Power consumption ≤ 70 W

Auxiliary connections Purge air

Options Interface module(s)I/O module(s)LC display19″-type

SLV4-2 purge air unit, 2BH1300, 3-ph

Description Obligatory purge air unit for purged volume flow measuring devices

Purge air quantity ≥ 48 m³/h

Diagnostics functions Low pressure controller

Ambient temperature

–20 °C ... +40 °C

Enclosure rating

IP54

Dimensions (W x H x D) 550 mm x 550 mm x 258 mm (for details see dimensional drawings)

Weight 18 kg

Auxiliary connections Purge air: 40 mm

Integrated components 2-step air filter, type Europiclon, dust capacity 200 g

Dimensional drawings (Dimensions in mm (inch))

FLSE100-HAC sender/receiver unit

A A

60 (2.36) 151 (5.94) 350/550 (13.78/21.65) Ø 100 (3.94)

Ø 1

25

(4

.92

)Ø 6

0

(2.3

6)

Ø 25

(0.98)

12

0 (

4.7

2)

2020-08-17 08:48:40 | Product data sheet

Subject to change without notice

FLOW MEASUREMENT TECHNOLOGY | SICK 9

Page 10: FLOWSIC100, Product data sheet · GAS FLOW MEASURING INSTRUMENTS VOLUME FLOW MEASURING DEVICES FOR CON-TINUOUS EMISSION MONITORING Ordering information Type Part no. FLOWSIC100 On

ABCDEF

HIJKLMNOPQRST

FLOWSIC100GAS FLOW MEASURING INSTRUMENTS

FLSE100-MAC sender/receiver unit

A A

12

0 (

4.7

2)

Ø 25 (0.98)

Ø 3

5

(1.3

8)

Ø 1

00

(3

.94

)

Ø 75 (2.95)60 (2.36) 182 (7.17) 350/500 (13.78/21.65)

FLSE100-PHS sender/receiver unit

A A

60 (2.36) 151 (5.94) 350/550/750

(13.78/21.65/29.53)

Ø 170 (6.69)

Ø 2

10

(8

.27

)

12

0 (

4.7

2)

Ø 40 (1.57)

Ø 7

6

(2.9

9)

FLSE100-PR sender/receiver unit

A A

12

0 (

4.7

2)

Ø 6

0

(2.3

6) Ø

12

5 (

4.9

2)

Ø 100 (3.94)60 (2.36) 140 (5.51) 506.5 (19.94)350/550/750

(13.78/21.65/29.53)

270 ... 280

(10.63 ... 11.02)

FLSE100-PM and FLSE100-PH sender/receiver unit

A A

60 (2.36) 140 (5.51) 200/350/550/750

(7.87/13.78/21.65/29.53)

Ø 100 (3.94)

Ø 1

25

(4

.92

)

12

0 (

4.7

2)

Ø 40 (1.57)

Ø 6

0

(2.3

6)

10 FLOW MEASUREMENT TECHNOLOGY | SICK Product data sheet | 2020-08-17 08:48:40

Subject to change without notice

Page 11: FLOWSIC100, Product data sheet · GAS FLOW MEASURING INSTRUMENTS VOLUME FLOW MEASURING DEVICES FOR CON-TINUOUS EMISSION MONITORING Ordering information Type Part no. FLOWSIC100 On

FLOWSIC100GAS FLOW MEASURING INSTRUMENTS

FLSE100-SA sender/receiver unit

A A

Ø 4

4.5

(1.7

5)

Ø 2

8

(1.1

0)

Ø 1

00

(3

.94

)

Ø 75 (2.95)70.5 (2.78) 125/200/350

(4.92/7.87/13.78)

FLSE100-SD sender/receiver unit

A A

12

0 (

4.7

2) Ø 2

8

(1.1

0)

Ø 1

00

(3

.94

)

Ø 75

(2.95)

60 (2.36) 157 (6.18) 125/200/350

(4.92/7.87/13.78)

Mounting flange with tube

L

M8

D1

D2

D3

D1 D2 D3 L Type FLSE100

113 SA, SD

188, 338 SA, SD, M

48.3 75 100

338, 538 M, MAC

188 H, PM, PH

338 H, HAC, PR, PM, PH

538 H, HAC, PR, PM, PH

76.1 100 122

738 H, PR, PM, PH

114.3 170 210 338, 538, 738 PHS

All dimensions in mm

2020-08-17 08:48:40 | Product data sheet

Subject to change without notice

FLOW MEASUREMENT TECHNOLOGY | SICK 11

Page 12: FLOWSIC100, Product data sheet · GAS FLOW MEASURING INSTRUMENTS VOLUME FLOW MEASURING DEVICES FOR CON-TINUOUS EMISSION MONITORING Ordering information Type Part no. FLOWSIC100 On

ABCDEF

HIJKLMNOPQRST

FLOWSIC100GAS FLOW MEASURING INSTRUMENTS

FLSE100-M sender/receiver unit

157 (6.18)

12

0 (

4.7

2)

60 (2.36) 200/350/550 (7.87/13.78/21.65) Ø 75 (2.95)

Ø 1

00

(3

,94

)A A

Ø 3

5(1

.38

)

FLSE100-H sender/receiver unit

A A

12

0 (

4.7

2)

Ø 6

0

(2.3

6)

Ø 1

25

(4

-92

)

Ø 100 (3.94)60 (2.36) 142 (5.59) 200/350/550/750

(7.87/13.78/21.65/29.53)

MCU-N control unit; wall-mounting enclosure, compact version (for non-hazardous areas only)

Meas

160 (6.30) 120 (4.72)

210 (8.27)

34

0 (

13

.39

)

32

0 (

12

.60

)

30

0 (

11

.81

)

12 FLOW MEASUREMENT TECHNOLOGY | SICK Product data sheet | 2020-08-17 08:48:40

Subject to change without notice

Page 13: FLOWSIC100, Product data sheet · GAS FLOW MEASURING INSTRUMENTS VOLUME FLOW MEASURING DEVICES FOR CON-TINUOUS EMISSION MONITORING Ordering information Type Part no. FLOWSIC100 On

FLOWSIC100GAS FLOW MEASURING INSTRUMENTS

MCU-P control unit; wall-mounting enclosure, compact version (for non-hazardous areas only)

Meas

Ø 8 (0.31)260 (10.24)

300 (11.81) 220 (8.66)

45

5 (

17

.91

)

42

0 (

16

.54

)

40

0 (

15

.75

)

SLV4-2 purge air unit, 2BH1300

Ø 10

(0.39)

55

0 (

21

.65

)

47

0 (

18

.50

)4

0

(1.5

7)

550 (21.65)

470 (18.50)

128 (5.04)

257 (10.12)

Ø 4

0

(1.5

7)

40

(1.57)

375.7 (14.79)

45

°

2020-08-17 08:48:40 | Product data sheet

Subject to change without notice

FLOW MEASUREMENT TECHNOLOGY | SICK 13

Page 14: FLOWSIC100, Product data sheet · GAS FLOW MEASURING INSTRUMENTS VOLUME FLOW MEASURING DEVICES FOR CON-TINUOUS EMISSION MONITORING Ordering information Type Part no. FLOWSIC100 On

Onlin

e da

ta s

heet

SICK AG | Waldkirch | Germany | www.sick.com

SICK At A GlAnCeSICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica-tions. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment.

We have extensive experience in a wide range of industries and understand their processes and require-ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner.

Comprehensive services complete our offering: SICK lifetime Services provide support throughout the ma-chine life cycle and ensure safety and productivity.

For us, that is “Sensor Intelligence.”

WOrldWIde preSenCe:Contacts and other locations – www.sick.com