Upload
trinhque
View
295
Download
13
Embed Size (px)
Citation preview
The World’s Premier Provider of Industrial Flow Management Services
TM
Flowserve CorporationProducts Serialization
The World’s Premier Provider of Industrial Flow Management Services
TM
Pumps Manufactured in the USProducts Serialization
The World’s Premier Provider of Industrial Flow Management Services
TM
Ingersoll-RandProducts Serialization
TM Pump Division
Month Year
or or
SequenceExamples0571-03 Engineered Thru 19860698-001 Engineered Thru 20000571-600 Split Case0571-800 2 Stage0191-2200 Small Motor Pump0386-3000 Sump Pump0386-4000 Gen Purpose
Prior to 1971A 56 - XXXX “A” Means OctoberB 61 - XXXX “B” Means NovemberC 69 - XXXX “C” Means December
Western Land Roller
0386-5000 Ansi Pumps0366-6000 Gen Purpose1290-7000 Fibre Glass (GRP)0280-8000 Inliners0588-9000 Hastings VTP0163-3000 All Pumps prior to 1963
Chesapeake Examples: 30-882196 (shop order)
30-09XXX (Export)
Prior to June 1939
TM Pump Division
Ingersoll-RandSerial Number Identification / Structure
<2011 Chesapeake - All Products0103-2262A Duplicate Unites
0103-2262B Have same S/N with A Letter Suffix
ALRIDGE RECIPROCATING PUMP LINEBoth the horizontal and vertical recip. lines were identified by a 2 digit number specifying the year followed by a 5 digit number. The month is not called for in the product line serial number series.
Example: 70-21696 (1970) - 3 1/2 X 5 V3 Pump90-24551 (1990) - 6 HS3 Pump
TM Pump Division
Ingersoll-RandSerial Number Identification / Structure
FORMER WESTERN LAND ROLLER MADE IN TANEYTOWN, MDThese units are identified by a 6 digit number preceded by a 2 digit ID number which is then followed by a 2 digit year of manufacture code.
42 - Export Complete Pump Order70 - Domestic Complete Pump Order73 - Bare Bowl Assembly Order45 - Quick Ship Complete Pump OrderExample: 93-70-200004 (1993) Domestic - 14JK Pump
The World’s Premier Provider of Industrial Flow Management Services
TM
WorthingtonProducts Serialization
TM Pump Division
Thru 1939
Thru 1970 Changed to 7 digit Numbers6 Digit Number
Then to 8 Digits1st 2 digits: 56 =Industrial Product, 55= Navy Product
TS Multi Stage - Year Prefix
IM All Pump line Export and Domestic
Z Split Case - Year Prefix
Worthington Serial Number Identification / Structure
56
7 Digit Number
8 Digit Number
TM Pump Division
Worthington
CHESAPEAKE (ex-Ampere)1st Series 1.010.950 to 1.581.699 (March 1941 to November 1958)2nd Series A-1000 to A-206325 (December 1958 to April 1969)3rd Series Y-429535 to ??? (April 1969 to ???)
Present number around Y-540.000 (1973)
Reformatted Serials
On Nameplate IM
Would be entered in ABOM as 5600
(to be consistent with latest 8 digit policy)
On Nameplate IK will be entered as 8400
TM Pump Division
Worthington
HARRISON New Jersey (Continued)A second series of numbers was introduced in January 1971. These numbers were broken down as part of the production was transferred to Glasgow (EPO) and was further segmented into Marine and Industrial Products. This series ran as follows:
Marine 55-00053Industrial 56-001033EPO 71-Z-00489
TM Pump Division
Worthington
TANEYTOWN MarylandThere is an unspecified serial number series used for vertical pumps built elsewhere from 1917 to 1945.1st series T-1.250.000 to T-1550597 (1946 - 1958)2nd series T-1.250.000 to T-28000 (1958 - 1969)3rd series VTP-28001 onward (1970 onward)
The last pump numbered in 1971 was VTP-33211.New
Year MonthM E (Engineered Vertical)M P (Non Engineered)M V (Rebowl)M S (Municipal)
Pump Built in Hastings will have serial No. The same as Taneytown with an “H” instead of an “M” ---- “M” = Maryland
“H” = Hastings
The World’s Premier Provider of Industrial Flow Management Services
TM
Byron Jackson, United, Wilson Snyder, Pacific and RLC
Products Serialization
TM Pump Division
Byron JacksonSerial Number Identification / Structure
Prior to 1965S/N consisted of six digits starting with 1, 2, 3, 4, 6, or 7Example: 303282
1965 through 1994Serial Number structures changed to designate the year, industry, region and number of unit Example: 651E0387 (65 - Year, 1 – All Else or 3 - Power Industry, E -Eastern Region, 0387 - Number of unit from that region (Additional Regions C=Chicago, H=Houston)
1994 through 1999S/N structure was similar to above except a region designator was added to the structure and the Industry designator removedExample: 94EA0001 (94 - Year, E - Eastern Region, A - Atlantic District, 0001 - Number of unit from that Region / District
TM Pump Division
United Centrifugal Pump (UCP)Serial Number Identification / Structure
These Serial Numbers are all five digits in length plus the number of identical units shipped
Example: 40521 – 1
The first five digits are the actual serial number, and the number after the dash is the unit number
5 Digit Number – Number of Units Shipped
TM Pump Division
Wilson SnyderSerial Number Identification / Structure
The Wilson Snyder product line is broken down into two categories own / make and purchased / nameplated.The series used will differ by pump type within both of those categories. Following are some examples:
1. Own / Make or referred to as “WS”
ES, ES-2, ESC 4 Digit 5000 thru 7999Series 100 CP + 3 digits CP100 thru CP299ESN 4 Digit 8000 thru 9999DV, HDS 5 digit 35000 thru 35999
TM Pump Division
Wilson SnyderSerial Number Identification / Structure
2. Purchases/Nameplated or referred to as “WSN”Crane Deming
DCXXXXXX Horizontal PumpsSPXXXXXX Sump PumpsTXXXXXX Vertical Turbine Pumps
FlowayFZZ-XXXX Vertical Turbine Pumps
AftonXXXX-WS Vertical Turbine or Vertical In-Line
(4 or 5 digits followed by “–WS”)
Lecourtney (Pro-Goulds)960 thru 3074 Horizontal Split Case Single & Multistage pumpModels BA, BD, M, MB, MBD, HVS
National-Oilwell Reciprocating Pumps• PXXX-XXXX Oilwell/National-Oilwell Horizontal Plunger
Piston Type Reciprocating Pump4XXXX Wilson Snyder Special Application Horizontal
Plunger or Piston Type Pumps
TM Pump Division
PacificSerial Number Identification / Structure
Original: 00000-35000 Number only2nd Generation: 35001-53000 Number only
In either Original or 2nd generation, Shop Order had a leading Prefix (aka “M”)Serial number is only the numeric sequence
Last: Serial Number = (letter)+(two spaces)+(number)+(unit seq)P 5120001 , Current shop order is a (letter) (00) 51200
Example: Shop order P0052100 EQUALS Serial P 5120001Letters meaning:
A - old style barrel A I type pump M - old style all othersB - Barrel AC, IJ, BFI D - 1 or 2 stage between bearing HVC, KHCG - Decoking Valve I - All other Decoking partsJ - More than 2 stages between bearing JTC L - Pumps bought from other vendorsP - 1 & 2 stage over hung HPX, SVCN, SVC or 1 or 2 stage vertical W, SPMC, CVSV - Can vertical WY, WYC
TM Pump Division
Pacific LicenseeSerial Number Identification / Structure
PREFIX MANUFACTURER or LICENSEE COUNTRYPH PACIFIC HIROZOKUI JAPAN
Mainly Latin America; Converted back to HP Design & BOMs updated; Moosic has 100% of records
X PEACOCK CANADAMainly Canada; Moosic has 100% of records
NONE WEIR ENGLAND to FRANCEExample 10359-XXX (5 numeric digits + 3 numeric digits)Mainly British Columbia; Moosic has 100% of records
TM Pump Division
Pacific LicenseeSerial Number Identification / Structure
PREFIX MANUFACTURER or LICENSEE COUNTRYNONE PULSOMETER
Example XXXXX-A /B (5 numeric digits )Optional: a Letter (A, B or C etc) may be used indicating sister pumps for the line item Example XXXXX-XXA/B (5 numberic digits - 2 numeric digitsOptional: a Letter (A, B or C etc) may be used indicating sister pumps for the line item Records in Arnage; ICBU
NONE WEIR PULSOMETER6-digits beginning with either 1, 2 or 3Example 1XXXXX ( 6 numeric digits)Optional: a Letter (A, B or C etc) may be used indicating sister pumps for the line item Records in Arnage; ICBU
NOTE all represent parts thru ICBU Process
TM Pump Division
Pacific LicenseeSerial Number Identification / Structure
PREFIX MANUFACTURER or LICENSEE COUNTRYDD DRESSER DUJARDIN FRANCE
Records Limited; Drawings need to be converted to HP Drawing
DF DRESSER FRANCE FRANCERecords Limited; Drawings need to be converted to HP Drawing
BC DRESSER BATIGNOLLES CHATILLON FRANCERecords Limited; Drawings need to be converted to HP Drawing
Note all represent challenge or risk with received BOMs at Moosic
TM Pump Division
PacificSerial Number Identification / Structure
Serial Number is a (letter) (two spaces) (number) (unit sequence)P 5120001
Current shop order is a (letter) (00) 51200
Example: Shop order P0052100 EQUALS Serial P 5120001
Letters meaning:A - old style barrel A I type pump M - old style all othersB - Barrel AC, IJ, BFI D - 1 or 2 stage between bearing HVC,
KHCG - Decoking Valve I - All other Decoking partsJ - More than 2 stages between bearing JTC L - Pumps bought from other vendorsP - 1 & 2 stage over hung HPX, SVCN, SVC or 1 or 2 stage vertical W, SPMC,
CVSV - Can vertical WY, WYC
The World’s Premier Provider of Industrial Flow Management Services
TM
Current: US Pumps ManufacturedProducts Serialization
TM Pump Division
Vernon RLCSerial Number Identification / Structure
RLCB, RLCS or RLCP Jobs Example: 01RLCB0049001001
YR Sold Job # Place Holder Serial No.01 RLCB00490 01 001
TM Pump Division
TaneytownSerial Number Identification / Structure
TANEYTOWN Maryland pump numbered in 1971 was VTP-33211.New 2011>
Year MonthM E (Engineered Vertical)M P (Non Engineered Vertical)M V (Rebowl)M S (Municipal)M L (Split Case, Non-Municipal)
• Pump Built in Hastings will have serial Number but in leiu of the Taneytown “T” will have a Hastings “H”. “M” = Maryland
“H” = Hastings• Secondary Design Center for NA New Units for LNN
TM Pump Division
ChesapeakeSerial Number Identification / Structure
>=2011 Current Chesapeake - All Products via ORACLE
XXXXXXXCHPXXX
First Seven digits (7) are the Oracle Chesapeake Business System order number
The Next set is the BU acronym (CHP=Chesapeake)
The last Three (3) digits are the line item for the orderOptional: a Letter (a,b,c, etc) may be used indicating sister pumps for the line item
TM Pump Division
S/N FRBH/Slurry pumpsCurrent 2011
Current BrantfordB + 6 digits & suffix
Example B110017-1Dropped O & region code
NOTE: as Product was moved to Taneytown for US distribution, please refer to TTY’s slide on serial number selection
BrantfordSerial Number Identification / Structure
TM Pump Division
S/N Rotary Pumps
Rotary - 2Screw/ GearexCurrent
Same as FRBH/R/M BrantfordB + 6 digits & suffix
BrantfordSerial Number Identification / Structure
The World’s Premier Provider of Industrial Flow Management Services
TM
Pumps Manufactured outside the USProducts Serialization
TM Pump Division
Desio, ItalySerial Number Identification / Structure
Pump Types: HN’s, HED, LN, UZD, HNNI, HDS, HE, HPX, HDX, HED, A, W, CGT, WNC)
Prior to moving to Desio, the Italian company was established in Milan and used numbers from 1 to 23562.After moving to Desio, the numbering structure was changed to add a “D” prefix
Serial Numbers: D23563, D46958 , D44037, D44506PART NUMBERS: 5642901280
Unique combination of part and material and qlty
Design Center for HPXParts Distribution Center for Desio is Caserta, Italy
TM Pump Division
Coslada, Spain (Madrid)Serial Number Identification / Structure
PUMP TYPES: UNB, UNQ, WXH, CHTA, CS, UZD, WN, HS, LNH, QL
Numbering system as follows:Start - 1961 25.000 to 50.0001961 - 1963 50.000 and up1963 - 1974 M.57136 and up1/75 - 7/79 M.109.493 to M.115.000 Newer Pumps may contain : M-151076Other SN examples: 0400E-101, 5285081
PART NUMBERS: 408220001
Design Center for WXH and CHTA
TM Pump Division
Brunn, AustriaSerial Number Identification / Structure
Pump types:ECP, ERP, WXLL, WUC, WWL, WXF
Serial Numbers: G202254, W312.150, W314149/60
PART NUMBERS PROVIDED PRIOR TO 2011 WERE A COMBINATION OF REFERENCE NUMBER FOLLOWED BY PART NUMBER
PART NUMBER COMPLETE: 477/02718
WITH MOVEMENT TO ORACLE, THE CORRECT PART NUMBER SEQUENCING IS 02718 AS THE REFERENCE NUMBER CREATED DUPLICATIONWILL BE MOVING TO “BRN-02718” AS WE RECONCILE/GLOBAL
TM Pump Division
Hamburg, GermanySerial Number Identification / Structure
Pump types: VSE-H, VTEM, VQEH, VTEL, HS, DS, UN, VE, VTE
SERIAL NUMBERS: HW26104, HW25235/6, HW30304/5
PART NUMBERS CONSISTS OF REFERENCE NUMBER FOLLOWED BY . AND IDENTIFICATION NUMBER ALSO INCLUDE EX-IR RECIP PART NUMBERING SEQUENCE
REFERENCE NUMBER - 328.00IDENTIFICATION # - 63133COMPLETE PART NUMBER - 328.00.63133
TM Pump Division
Newark, EnglandSerial Number Identification / Structure
Pump types: LNN, WJE, MC, BPO, D, DC, WJ,WPG, CR, LN, GRP, (DX for EMA as well)
SERIAL NUMBERS: F075604/5 K61S, 156142, 2415060, HW30365 (FOR LN ONLY)
PART NUMBERS: N646GS079 , J376GS009
Design Center in collaboration with Arnage for LNN
TM Pump Division
Arnage, FranceSerial Number Identification / Structure
PUMP TYPES: LN, HV, LCH, LNN, LNE, SNL, FP, NM, ME, CNX
SERIAL NUMBERS - SP57200041-01, 1359903, DF2172, HW30365 (FOR LN ONLY)
PART NUMBER - 719195, 662245
Design Center in collaboration with Newark for LNN
TM Pump Division
Etten Leur, EnglandSerial Number Identification / Structure
PUMP TYPES: DAD, DVMX, BTC, VNN 6Y, DSTHF, SMJ , DMX
SERIAL NUMBER - 6114094, 210501, 75PD0203
PART NUMBER – 251173527820 AX215127 BH000
Design Center for DMX
TM Pump Division
Hengelo, NetherlandsSerial Number Identification / Structure
PUMP TYPES: PVML , PHL
SERIAL NUMBERS: 03HY0870 , 32830
PART NUMBER – 00046578, V3482643
TM Pump Division
Santa Clara, MexicoSerial Number Identification / Structure
Pump types: HPX, APM, APH, DVH,DVMX Soon will be making WXH as well
SERIAL NUMBERS: 06HE0014, 00PB1025, 02PE0012, 08IE0130, 10ME0210
PART NUMBERS: 4023320790, MB000255 568039GU
HPX: PART NUMBERS SHOULD MIRROR DESIGN CENTER DESIOWXH: PART NUMBERS SHOULD MIRROR DESIGN CENTER COSLADAEX-IR VERTICALS: OLD IR SEQUENCING
Design Center for Larger Verticals
TM Pump Division
Mendoza, ArgentinaSerial Number Identification / Structure
Pump types: DMX, DMX(D and H)
SERIAL NUMBERS: 06AE00084First two numbers are the YEAR of the BOM, AE=Argentina, followed by the next sequential number
PART NUMBERS: ex-IR DA and ex-BJ DVMX, seal division, as well as their own
CCN=1115 sequence when they create new part, old parts would be the ex-IR and ex-BJ or legacy part numbering sequence
Manufacturing Center for Multi-stage Pumps
TM Pump Division
Rio deJaneiro, BrazilSerial Number Identification / Structure
Pump types: LN, HDS, WDE, M, D1011
SERIAL NUMBERS: BX85950, 35502.01.01
JapanSerial Number Identification / Structure
Pump types: CNEC, LN, HNNI, KCA
SERIAL NUMBERS: 38675, 27903