105
2010 www.mess-regeltechnik.at • Flow • Temperature • Pressure • Level • Pumps • Systems • Service & Calibration LICO +43 1 706 43 000 LICO Electronics GmbH Klederinger Str. 31 A-2320 Kledering, Austria [email protected] www.lico.at Tel. +43 1 706 43 00

Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Embed Size (px)

Citation preview

Page 1: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

2010www.mess-regeltechnik.at

• Flow

• Temperature

• Pressure

• Level

• Pumps

• Systems

• Service & Calibration

LICO +43 1 706 43 000

LICO Electronics GmbH Klederinger Str. 31

A-2320 Kledering, Austria [email protected] www.lico.at Tel. +43 1 706 43 00

Page 2: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Foreword 01Roxspur Measurement & Control 04How to Order 05New Products in this Issue 06

Flow Overview 08Quick Reference Guide to Flow Products 10Ranges for Glass Tube and Float 11

VA Flowmeters NGX/LGX Series Glass VA Flowmeter 12NGX Series Glass VA Flowmeter 14LGX Series Glass VA Flowmeter 15NGX/LGX Series - Accesories 16 GU Safety Housed Glass VA Flowmeter 17PG Plastic VA Flowmeter 18PGU Safety Housed Plastic VA Flowmeter 19DFM Plastic VA Flowmeter 20NG/LG Series Glass VA Flowmeter 22GR Miniature Plastic VA Flowmeter 23SGUV Shunt Orifice Flowmeter 24LPCB Fire Sprinkler Flowmeter 25100mm Scale Glass Tube & Float 26Anaesthetic Glass Tube & Float 27GIR (Floscan) Infra-Red Flow Alarm 28Spares & Accessories 29GMT Series Metal Tube VA Flowmeter 30GMT Flanged Series Flowmeter 32GMT Threaded Series Flowmeter 33GMT Series Transmitter/Alarm Options 34Mains Interface Relay Module 35Variable Orifice/Swing Vane 36AP Purgemeter/GPI Digital Liquid Turbines 37High Pressure Liquid/Compressed Air 38EPW Oil & Water Flowmeter 39

Turbine Flowmeters Stainless Steel Turbine & Pelton Wheel 40Digital Indicators 41

Electromagnetic Flowmeters Model 910 Electromagnetic Flowmeter 42Mag X1 Electromagnetic Flowmeter 43

Ultrasonic Flowmeters Model 220 Portable Ultrasonic Flowmeter 44Field Mount Ultrasonic Flowmeters 45Ultrasonic Flowmeter/Switch 46

Laminar Flowmeters Laminar Water Flow Transmitter 48Laminar Gas Flow Transmitter 49

Primary Flowmeters In-line Pitot ‘Flo-bar’ Pipe Section 50Insertion Pitot Tube 50

Totalising Flowmeters Water Meter/Oil Meter 51

Flow Controllers Pre-set Flow Controller 52MN/FV Automatic Flow Controllers 53Automatic Flow Controllers (B and LB Flostats) 54Automatic Flow Controllers 55

Indicators Paddle Wheel/Ball 56Flap/Plain 57

Switches Pre-Set Flow Switch 58Adjustable Liquid Flow Switch 59

CONTENTS

www.mess-regeltechnik.at2

Flow

Page 3: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

+43 1 706 43 000 3

CONTENTS

Switches Paddle (Liquid) Flow Switch 60Explosion Proof Flow Switch 61Adjustable Paddle Flow Switches 62Air/Liquid Mini Flow Switches 63Explosion Proof Adjustable Flow Switch 64Level Switches (Plastic Float & Stainless Steel) 65Vertical Stainless Steel & Pair Drop 66

Level Capacitance Level Transmitter 67Ultrasonic Level Transmitter 68Level Control Electrodes 69Pump Control or Level Alarm Module 69

Valves Proportional Control Valves 70FCV Fine Control Valves 71Needle Valves 72Solenoid Valves (2 Way/3 Way Direct Acting) 73Solenoid Valves (Servo-Acting/Coupled Diaphragm) 74

Technical Data VA Flowmeter Sizing Data (Liquids) 75VA Flowmeter Sizing Data (Gases) 76Unit Conversions & IP Table 77

Pressure Overview 78mV Transducer/OEM Transmitters 80General Purpose Pressuure Transmitters 80HPS Series Transmitter 81Economic Industrial Transmitters 81PMC Overview 82PMC Miniature Pressure and Level Transmitters 83PMC Electronic Transmitters 83Electronic Pressure Switch - Switch 2000 84UDS2 Indicating Switch/Pressure Switch 85Pressure Gauges 86Low DP Gauge (Gases) 88DP Gauge with Alarm/Transmitter 89DP Flow Transmitter 90High Precision Pressure Regulator 91Electronic I/P Converters 91Pressure Reducing Valve 92Water Pressure Regulator Non-Relieving 92Water Pressure Regulator 93Pressure Relief Valve 93

Temperature Overview 94MicroCal 20 Series/ Instrumentation 98Thermal Imaging Camera 99Infrared Thermometer 99

Service & Calibration Overview 100Capabilities 101

Pumps Overview 102Wanner Hydra-Cell Pumps 103Series 2000 Utility Pumps/Yamada Pumps 103

Systems Overview 104

Contact us 106RM&C Instrumentation 107Terms and Conditions 108

Pressure

Temperature

Calibration

Pumps

Systems

Page 4: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

NEW PRODUCTS IN THIS ISSUE

www.mess-regeltechnik.at6

NGX/LGX - Glass VA Flowmeters

LPCB Approved Fire Sprinker Flowmeters

GMT Low Pressure Drop Metal VAFlowmeters

Automatic Flow Controllers

Capacitance Level Transmitters

Ultrasonic LevelTransmitter

UltrasonicFlowmeter/Switch

MagX1 ElectromagneticFlowmeters

Page 12 Page 25

Page 30 Page 43

Page 46 Page 54

Page 67 Page 68

Page 5: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

0043 1 706 43 000 7

Process Calibrator

PMC Pressure and Level Transmitters

Sensit PressureTransmitters

Infrared Thermometer

Thermal ImagingCamera

Pressure SwitchElectronic PressureSwitch

NEW PRODUCTS IN THIS ISSUE

Page 83Page 81

Page 84 Page 85

Page 98 Page 99

Page 99

Can’t find what you’re looking for thencall our

TECHNICAL SALES TEAM

as we can supply tailor-made solutions

Page 6: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

www.mess-regeltechnik.at

FLOW OVERVIEW

8

RM&C Platon Specialist UK manufacturer with 50 years experience

Industry leader for all your flow requirements FLOWBITS catalogue

Flow Measurement UK leading manufacturer of glass

and metal VA flowmeters Custom products or systems Application sales engineers to discuss

your requirements

Flow Products Wide variety of VA flowmeters LPCB approved models for fire sprinkler systems Control valves Ultrasonic and mass flowmeters Many other types, please enquire

FLOW

Page 7: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

+43 1 706 43 000

FLOW OVERVIEW

9

• Pipe sizes from 1 1/4" to 24" (32 to 610 mm)

• Rugged well proven design

• Flanged or victaulic fittings

• For clean liquids and gases

• LPCB approved models for fire sprinklers

• Orifice plates and carrier assemblies available

• Remote indication versions

• New extended flow ranges

Ultrasonics Flowmeters

Electromagnetic FlowmetersAutomatic Control Valves

Shunt Orifice Flowmeters

Metal VA FlowmetersGlass & Plastic VA Flowmeters

• New NGX and LGX series

• Gas flow up to 440 L/min

• Liquid flow up to 40 L/min

• Simple to install and maintain

• Customised scales

• Alarm option, ATEX approved

• Anaesthetic flowmeter range

• Safety housed versions

• Pipe sizes from 1/4" to 4" (6 to 100 mm)

• Maintains flow at selected rate

• Independent of pressure fluctuations

• Gases or liquids

• No power required

• Adjustable over wide range

• Fast response

• Highly accurate

• No moving parts in the flowprofile

• Configuration data is backed up and can berecovered

• Datalogging function

• Diagnostic facility

• Gas flow up to 1000 m3 /hr

• Liquid flow up to 100 m3 /hr

• Pipe sizes from 1/2" to 4" (15 to 100 mm)

• Configurable to customer specification

• Low pressure drop versions

• Simple to install, use and maintain

• Alarm and transmitter options

• ATEX intrinsically safe approval

• Flanged or screwed options

• Non-invasive flow measurement

• Dual mode

• 6mm to 6.5m (1/4" to 256") pipe sizes

• All commonly used pipe materials

• ATEX Certified Version

• Portable or fixed models

FLO

W

Page 8: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

QUICK REFERENCE GUIDE TO FLOW PRODUCTS

Flow Switches

Flow Regulators/Controllers

Material Product Type Page Air Water Oil Other mediums

Min Max Unit Min Max Unit Min Max Unit Gas Liquid

Glass* FLGX VA 15 0.005 25 L/min 1 40 L/hr On application Yes Yes

SS* FAP VA 37 0.5 25 L/min 1 60 L/hr On application Yes Yes

Plastic FGR VA 23 0.03 100 L/min 0.005 0.3 L/min No No

Glass* FNGX VA 14 0.005 150 L/min 0.002 4.4 L/min On application Yes Yes

Plastic* FPG/FPGU VA 18-19 10 440 L/min 1 40 L/min On application Yes Yes

SS FFLM Mass 48-49 0.000005 1000 L/min 0.000005 10 L/min Yes Yes

Plastic FFT Turbine 40 n/a n/a n/a 0.1 100 L/min On application No Yes

Brass FFLA†/

FFLW/FFLL VA 38 3.6 360 m3/hr 0.2 100 L/min 0.2 100 L/min No Yes

Plastic FEFW/FEFL VA 39 n/a n/a n/a 1 150 L/min 1 150 L/min No No

Various FGP Turbine 37 n/a n/a n/a 1 190 L/min On application No Yes

Br/SS* FGMT VA 30-34 0.5 1000 m3/hr 0.02 25 m3/hr On application Yes Yes

Plastic FFVA VA 20-21 0.7 1500 m3/hr 0.015 50 m3/hr On application Yes Yes

Glass* FSGU Shunt VA 24 30 1500 m3/hr 2 100 m3/hr On application Yes Yes

Various FFL/FFM VA 36 On application 0 270 m3/hr On application Yes Yes

SS FNT/FBNO Turbine 40 On application 0.01 60 m3/hr On application Yes Yes

Various POA Electro Mag 42-43 n/a n/a n/a 0.1 10 m/s On application No Yes

Various POA Ultrasonic 44-45 On application 0.01 25 m/s On application Yes Yes

* manufactured by RM&C† calibrated at 7bar G, 20° CStandard calibration for all products, unless specified by supplier or customer, is ATP - 1.013 bar A, 20° C

Material Product Type Page Gas/Air Liquid/Water

Min Max Unit Min Max Unit

SS* FLF Piston 58 n/a n/a n/a 0.5 3.5 L/min

Brass* FLF Piston 58 n/a n/a n/a 0.5 10 L/min

Brass/SS FFSV6 Vane 61 9 60 m3/hr 4 30 L/min

Brass/SS FV10/FV11¥ Vane 63 15 85 m3/hr 9 36 L/min

Brass/SS FMR Piston 59 n/a n/a n/a 0.4 40 L/min

Brass/SS F593/F594 Vane 60 n/a n/a n/a 2.5 53 L/min

Plastic FV8¥ Vane 62 55 286 m3/hr 34 170 L/min

Brass/SS FVK¥ Vane 62 n/a n/a n/a 1.1 173 m3/hr

Brass/SS FFSV4 Vane 64 29 16920 m3/hr 0.7 545 m3/hr

* manufactured by RM&C¥ check if actuation/de-actuation switching

Material Product Type Page Air Water Other mediums

Min Max Unit Min Max Unit Gas Liquid

Brass/SS* FMN Diaphragm 53 0.005 100 L/min 0.002 3.5 L/min Yes Yes

Brass/SS* FFV Diaphragm 53 0.08 2200 m3/hr 0.02 75 m3/hr Yes Yes

Brass/SS* FB Diaphragm 54 n/a n/a n/a 4 100 m3/hr No Yes

Brass/SS* FLB Diaphragm 54 n/a n/a n/a 2 240 m3/hr No Yes

* manufactured by RM&CStandard calibration for all products, unless specified by supplier or customer is ATP - 1.013 bar A, 20° C

Flow Meters

FLOW

METER

S

www.mess-regeltechnik.at10

Page 9: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

@ A

TP L

/min

(*

=cm

3/m

in)

FGTF

1C

HD

--

5-10

0*-

10-1

50*

5-80

*20

-120

*10

-100

*10

-100

*10

-120

*10

-100

*25

-280

*10

-150

*5-

100*

5-90

*30

-140

*

FGTF

1B

HD

--

20-2

50*

-30

-350

*20

-200

*50

-290

*30

-250

*20

-250

*30

-360

*20

-280

*50

-600

*40

-360

*20

-250

*20

-220

*40

-300

*

FGTF

1A

HD

--

60-6

00*

2-40

50-9

00*

60-5

60*

100-

700*

50-7

00*

50-7

00*

0.1-

1.1

50-8

00*

0.2-

20.

05-1

60-6

00*

40-6

00*

100-

750*

FGTF

1A

HS

2-25

*-

0.1-

1.2

5-70

0.1-

1.5

0.1-

10.

1-1.

10.

1-1

0.1-

1.2

0.1-

1.8

0.1-

1.8

0.2-

3.4

0.1-

1.7

0.1-

1.2

0.1-

1.1

0.1-

1.2

FGTF

1A

SS10

-80*

0.6-

4.6

--

--

--

--

--

--

--

FGTF

2C

HD

--

0.2-

2.0

10-1

200.

3-2.

50.

2-1.

70.

4-2

0.2-

1.8

0.2-

20.

3-3

0.2-

30.

4-5

0.4-

2.8

0.2-

20.

2-1.

80.

3-2.

2

FGTF

2CD

SP-

-0.

2-3.

4-

--

--

--

--

--

--

FGTF

2B

HD

--

0.6-

5.0

30-3

000.

8-5.

80.

6-4

0.8-

40.

8-4.

40.

6-5

1-8

0.5-

91-

151-

70.

6-5

0.6-

4.4

0.8-

4.8

FGTF

2B

HS

20-2

80*

1-16

1-10

--

--

--

--

--

--

-

FGTF

2A

HD

--

1-12

50-7

001-

141-

101-

101-

101-

122-

222-

282-

441-

181-

121-

121-

11

FGTF

2A

HS

50-8

00*

2-46

2-25

-2-

282-

222-

182-

202-

262-

484-

605-

952-

362-

251-

252-

22

FGTF

2A

SS0.

2-1.

510

-90

--

--

--

--

--

--

--

FGTF

3A

HD

--

6-50

-6-

544-

404-

364-

404-

5010

-90

10-1

2010

-180

10-6

56-

504-

484-

40

FGTF

3A

HS

0.2-

3.0

10-1

8010

-100

-10

-110

10-8

510

-75

10-8

010

-100

20-1

8020

-270

40-3

8015

-140

10-1

0010

-100

10-8

5

†FG

TF 3

ASS

0.4-

4.4

20-2

7030

-150

--

30-1

30-

30-1

20-

--

--

30-1

5030

-140

30-1

20

CE

BD

FJ

MR

GK

NS

HL

PT

Scal

e C

od

e

CE

BD

FJ

MR

GK

NS

HL

PT

Tub

eC

od

e

Wat

er@

20

ºC

(*=

cm3

/min

)L/

min

L/

Hr

Air

@ A

TP

(*=

cm3

/min

)L/

min

L/

Hr

Acetylene

Argon

Butane

Carbon Dioxide

Carbon Monoxide

Cracked Ammonia

Helium

Hydrogen

Methane

Nitrogen

Oxygen

Propane

RequiredFrame Size 1 2 3

FLO

WM

ETER

S

Po

pu

lar

ran

ges

fo

r G

lass

Tu

be

and

Flo

ats

@ A

TP (1

.01

3 b

ar A

,20

ºC)

†FG

TF3A

SS (f

or

gas

es) n

ot

suit

able

to

be

use

d w

ith

th

e G

IR In

fra-

Red

flo

w a

larm

on

pag

e 28

•O

ther

gas

an

d li

qu

id s

cale

s an

d c

ust

om

cal

ibra

tio

ns

are

avai

lab

le,c

on

sult

ou

r Tec

hn

ical

Sal

es T

eam

for

det

ails

•U

KA

S o

r IS

O 1

7025

Cal

ibra

tio

n a

vaila

ble

RANGES FOR GLASS TUBE AND FLOAT

+43 1 706 43 000 11

Page 10: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Data Sheet DS1115

Specification

NGX/LGX SERIES GLASS VA FLOWMETER

ENGINEERED TO FIT

• Standard or custom scaled glass tubes to suit process fluids and conditions

• Range of process connections to fit pipework requirements

• Brass or stainless steel end blocks with optional integral flow control valve

• Supplied with studs for surface panel mounting

ACCURATE MEASUREMENTFlow up the tapered tube lifts the float to an equilibrium position.Flow rate is then measured against the flat top edge of the float.

FLOWMETER CHOICEA complete VA flowmeter consists of a glass flow tube and floatscaled to the flow units required, and a frame to provide the endblock supports and to cover and protect the tube. The NGX Seriesframes use flow tubes with nominally 100mm long scales,whereas the smaller LGX frames use flow tubes with nominally30mm scales.

To choose a complete flowmeter select the frame code required,and separately specify the fluid flow range needed on the flowtube scale.

NGX and LGX Series frames are designed to fit your process. The options available allow easy installation, usuallysurface mounted on a vertical panel. Process connections and labelling can be customised to suit the application.

NGX/LGX

• Easy to use, high visibility scale

• Rear ‘blow out’ safety vent

• UV stabilised rigid safety cover

• Gas or liquid flow measurement

• Instantaneous response

• Accuracy up to ±1.25% FSD

• Air flow range 5mL/min to 150 L/min

• Glass tube removal without tools

• ATEX Infra-red alarm option

• Range of accessories

• UKAS calibration optional

• Available from stock

• Next day delivery

(subject to specification)

FLOW

METER

S

www.mess-regeltechnik.at12

Page 11: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

NGX/LGX SERIES GLASS VA FLOWMETER

Dims NGX LGX

W 30mm 30mmX 121mm 65mmY 184mm 108mmZ 210mm 134mm

Flowmeter TypesNGX – Standard size (100mm scale)LGX – Reduced size (30mm scale)

End Block StyleI – In-line connectionsT – Rear facing connectionsV – Built in needle valve with rear connections

End Block MaterialB – Brass S – Stainless

Process Connections1 = 1/4" BSPP2 = 1/4" NPT

O-ring Seals1 = Nitrile2 = Viton

Frame SizeChosen to suit flow tube required

Standard Frame Codes

External Connections

Typical Model: NGX T B 3 1 2

Process Connections:Standard 1/4" BSPP or 1/4" NPT, 20mm ODMounting Stud:M5 threaded with nut to locate meter on vertical panelSafety Vent:Allows rear discharge of process fluid in event of glass tube breakage. Dia 20mm

OUT

IN

W

XY

ZC/L

Custom Build

Construction of the NGX and LGXseries frames makes custom build orspecial process connections easilyachievable, whether for rear facingor mixed rear/in-line fittings.

Specific custom logos can be printedon the glass tubes and polycarbonatecovers if required to suit theapplication.

Backplate White polyester powder coated aluminiumEnd Blocks Suffix B – Bright nickel plated brass; Suffix S – Stainless steelSeals Nitrile on brass units; Viton on stainless steel units; Alternative seals availableCover Clip on clear UV stabalised rigid polycarbonate (required to locate flow tube into end blocks)Connections Models available with in-line or rear facing process connections (See page 14/15)Max. Temp 100°C with viton seals, 80°C with nitrile sealsMax. Pressure Recommended maximum operating in non-shock applications: 16 barValve Option Fine control valve option has needle valve fitted on flowmeter inletMounting Stud M5 studs 13mm long c/w nut

Flowtube Borosilicate glass, precision moulded in three diameters to suit flow rangeScale Fused ceramic black inkScale Length NGX Series – 100mm nominal

LGX Series – 30mm nominalFloat Precision machined float, rotates to give flow visualisation

Model HD: Hollow Dural, red anodisedModel HS: Hollow Stainless SteelModel SS: Solid Stainless Steel

Accuracy ±1.25% FSD standard for NGX Series(±2.5% for 1CHD/BHD models, ±3% for predicted scales) ±5% FSD for LGX Series

Calibration All tubes are flow tested. Standard scales arefor air & water, as listed. Custom scales to suit process fluid

Specification - Frames

Specification - Flowtubes

FLO

WM

ETER

S

+43 1 706 43 000 13

Page 12: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

NGXV - Integral Valve NGXI/NGXT- Non-valved

NGX SERIES GLASS VA FLOWMETER

Product Codes Product Codes

Options (see page 16)

• Bench Stand

• GIR Alarm

• Relay Module

• UKAS Calibration Certificate

Options (see page 16)

• MN Flostat Valve

• GIR Alarm

• Relay Module

• UKAS Calibration Certificate

Plated BrassFNGXVB111FNGXVB211FNGXVB311

Stainless SteelFNGXVS121FNGXVS221FNGXVS321

Plated BrassFNGXIB111 FNGXTB111FNGXIB211 FNGXTB211FNGXIB311 FNGXTB311

Stainless SteelFNGXIS121 FNGXTS121FNGXIS221 FNGXTS221FNGXIS321 FNGXTS321

FLOW

METER

S

www.mess-regeltechnik.at14

Page 13: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

LGXV - Integral Valve

LGX SERIES GLASS VA FLOWMETER

Product Codes Product Codes

Options (see page 16)

• GIR Alarm

• Relay Module

• UKAS Calibration Certificate

Plated BrassFLGXVB111FLGXVB211

Stainless SteelFLGXVS121FLGXVS221

Options (see page 16)

• MN Flostat Valve

• GIR Alarm

• Relay Module

• UKAS Calibration Certificate

Plated BrassFLGXIB111 FLGXTB111FLGXIB211 FLGXTB211

Stainless SteelFLGXIS121 FLGXTS121FLGXIS221 FLGXTS221

LGXI/LGXT - Non-valved

FLO

WM

ETER

S

+43 1 706 43 000 15

Page 14: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

NGX/LGX SERIES - ACCESSORIES

FLOW

METER

S

UKAS Calibration Certification available

MN Flostat - Automatic Flow ControllerFully automatic, no external power required. Maintainsconstant flow regardless of line pressure fluctuation. Seepage 53 for full specification and ordering information.

GIR Infra-red Alarm

• Intelligent sensor for high or low alarm

• Use two units for dual alarms

• ATEX approved

See page 28 for full specification and orderinginformation.

Relay Module

DIN rail surface mount mains interface relaymodule provides power for one or two GIRalarm units.

See page 35 for full specification and orderinginformation.

Bench standMounts to NGX series flowmeters and allows verticalbench mounting. See page 29 for ordering information.

www.mess-regeltechnik.at16

Page 15: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Data Sheet DS1111

GU SAFETY HOUSED GLASS VA FLOWMETER

Specification

Product Codes

Connections 3/8" BSPP Female in-lineHousing Polyester coated die cast AluminiumEnd Fittings Nickel Plated Brass or Stainless SteelSeals Nitrile with Brass (80°C max); Viton with Stainless Steel (100°C max)Window Solid perspex (Note - toughened glass window option)Pressure 25 bar max, non-shockRelief Vent Rear facing pressure relief ventInstallation Vertical with flow upwards - read top of floatDimensions 210 x 73 x 60mm depth

• Robust construction

• Instant flow rate visual indication

• Suitable for installation in unsupported pipework

• Flow tube scaled for any gas andmost liquids

• Safety housed for operator protection

• Site interchangeable 100mm scale length tubes

• Alarm option available (See page 28)

• Optional fine control valve (inset shown)

• First choose tube from page 11 then choose frame size and connection

Model Description Frame Size CodeStandard GU with Brass end blocks Size 1 FGUB111

Size 2 FGUB211 Size 3 FGUB311

Standard GU with Stainless Steel end blocks Size 1 FGUS112 Size 2 FGUS212 Size 3 FGUS312

• For optional Fine Control Needle Valves (see page 71)

The GU construction provides a rigid protectivestructure around the flow tube, to allow installationin unsupported pipework or to provide extraprotection to operators on high pressure or corrosiveapplications.

FLO

WM

ETER

S

+43 1 706 43 000 17

Page 16: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Data Sheet DS1140

Specification

Product Codes

PG PLASTIC VA FLOWMETER

Variable area flowmeters for higher flowrates in1/2" and 1” pipes, using plastic TPX tubes andStainless Steel or Dural floats. Open design forgood float visibility.

• Large flow capacity for use on 1/2" and 1" lines

• High visibility

• Instantaneous operation

• Suitable for use on a wide range of liquids and gases

• Special scale options

• Low pressure drop

Tube TPX plasticScale Black, moulded onto plastic tubeFloat Duraluminium for gases, Stainless Steel for liquidsAccuracy ±5% FSD (Air and Water calibrations)Housing White Polyester coated Mild SteelConnections 1/2" & 1" BSPP Female plated Brass or Stainless SteelO-Ring Seals Nitrile with Brass, Viton with Stainless SteelTemperature 80°C maxPressure Limit 10 bar at 20°CInstallation Vertical with flow upwards - read top of floatDimensions (mm) 1/2"= 219 x 48 x 48 1" = 250 x 67 x 67

Flow Rate (ATP) Connections BSP Brass Connections Stainless ConnectionsL/minAir10 - 100 1/2" FPGB1 FPGS1 20 - 180 1/2" FPGB2 FPGS2 40 - 440 1" FPGB3 FPGS3

Water1 - 10 1/2" FPGB4 FPGS4 2 - 22 1" FPGB5 FPGS5 4 - 40 1" FPGB6 FPGS6

• Laminated scales are available for other fluids and process conditions. Please contact our Technical Sales Team for details.

FLOW

METER

S

www.mess-regeltechnik.at18

Page 17: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Data Sheet DS1140

PGU SAFETY HOUSED PLASTIC VA FLOWMETER

Specification

Product Codes

Plastic tube flowmeters in rugged safety housingssuitable for unsupported installation in processpipework. Perspex cover retains easy readabilitywhile protecting the operator.

• Large flow capacity for use on 1/2" and 1" lines

• High visibility

• Instantaneous operation

• Suitable for use on a wide range of liquids and gases

• Glass tube or special scale options available

• Low pressure drop

Tube TPX plastic. Borosilicate Glass available as an optionScale Black, moulded onto plastic tubeFloat Duraluminium for gases, Stainless Steel for liquidsAccuracy ±5% FSD (Air and Water)Housing Polyester coated die-cast Aluminium with perspex windowConnections 1/2" & 1" BSPP plated Brass or Stainless Steel, optional flanged fittingsO-Ring Seals Nitrile rubber on Brass, Viton on Stainless SteelTemperature 80°C maxPressure 10 bar max at 20°CExhaust Vent Rear facing blowout ventInstallation Vertical with flow upwards - read top of floatDimensions 250 x 95 x 86mm depth

Flow Rate (ATP) Connections BSP Brass Connections Stainless ConnectionsL/minAir 10 - 100 1/2" FPGUB1 FPGUS1 20 - 180 1/2" FPGUB2 FPGUS2 40 - 440 1" FPGUB3 FPGUS3

Water 1 - 10 1/2" FPGUB4 FPGUS4 2 - 22 1" FPGUB5 FPGUS5 4 - 40 1" FPGUB6 FPGUS6

• Laminated scales are available for other fluids and process conditions. Please contact our Technical Sales Team for details.

FLO

WM

ETER

S

+43 1 706 43 000 19

Page 18: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Data Sheet DS1113

DFM PLASTIC VA FLOWMETER

All plastic construction VA flowmeters providing excellent chemical resistanceand readability, supplied complete with end connections, either for solventwelding to PVC pipe or threaded. Up to three bi-stable alarms can be fitted toeach unit, or if required a 4-20mA transmitter is available. Over the last ten yearsmany thousands of DFM units have been supplied to practically every industryin the UK. All units are available on quick delivery from our extensive stock.

• 0.75 - 1500 m3/hr Air in 14 ranges each with 10:1 operatingspan

• Choice of tube materials depending upon operatingtemperature and pressure up to 100°C and 10 bar

• Positive pipe O-ring sealing requires less torque when installing

• Options of alarms or 4-20mA transmitter available

• Standard or magnetic floats(where alarms are required) of identical mass, ensure that the calibration is retained if the floats are replaced

Please contact our Technical Sales Team on

0870 2200724

Also available with shorter tube lengths, alternative materials, smaller pipesizes and lower flow ranges. Please contact our Technical Sales Team for details.

FLOW

METER

S

www.mess-regeltechnik.at20

Page 19: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Pipe Range Solvent BSPSize Air Weld Threads

(m3/hr)1" 0.7 - 5.5 FFVA0000 FFVA00141" 1.0 - 10.0 FFVA0001 FFVA00151" 2.5 - 20 FFVA0002 FFVA00161" 4 - 34 FFVA0003 FFVA001711⁄4" 5 - 50 FFVA0004 FFVA001811⁄4" 8.5 - 76 FFVA0005 FFVA001911⁄2" 8 - 70 FFVA0006 FFVA002011⁄2" 10 - 90 FFVA0007 FFVA00212" 14 - 125 FFVA0008 FFVA00222" 22 - 190 FFVA0009 FFVA00232" 35 - 300 FFVA0010 FFVA002421⁄2" 50 - 500 FFVA0011 FFVA002521⁄2" 80 - 720 FFVA0012 FFVA002621⁄2" 400 - 1500 FFVA0013 FFVA0027

OPTIONSBi-stable Alarm FFVA0056 4-20mA Transmitter FFVA0057

Pipe Range Solvent BSPSize Water Weld Threads

(L/hr)1" 15 - 150 FFVA0028 FFVA00421" 30 - 300 FFVA0029 FFVA00431" 60 - 600 FFVA0030 FFVA00441" 100 - 1000 FFVA0031 FFVA004511⁄4" 150 - 1500 FFVA0032 FFVA004611⁄4" 250 - 2500 FFVA0033 FFVA004711⁄2" 200 - 2000 FFVA0034 FFVA004811⁄2" 300 - 3000 FFVA0035 FFVA00492" 400 - 4000 FFVA0036 FFVA00502" 600 - 6000 FFVA0037 FFVA00512” 1000 - 10000 FFVA0038 FFVA005221⁄2" 1500 - 15000 FFVA0039 FFVA005321⁄2" 2500 - 25000 FFVA0040 FFVA005421⁄2" 10000 - 50000 FFVA0041 FFVA0055

DFM PLASTIC VA FLOWMETER

Specification

Product Codes

Pipe Size 1, 11⁄4", 11⁄2", 2 and 21⁄2" NBProcess Connections Solvent weld or BSP Female threadsTube Length 350mmOverall Length 400, 408, 418, 432 or 444mm (dependant upon pipe size)Wetted Materials Polyamide tube, PVC connectors, EPDM O-rings & PVDF internalsAccuracy ±1.2% of reading ±0.4% of full scalePressure 10 bar max at 20°C (de-rate to 1 bar at 75°C)Temperature 75°C maxStandard Conditions Air and water at 20°C and 1 bar A

PipeworkMainly used for rigid PVC imperial pipe. Alternative screwed BSP female insertsavailable. Other connections and materials are also available, please contact ourTechnical Sales Team for more details.

ValvesFor liquids may be installed upsteam or downstream. For gases install valvesdownstream only.

Special ScalesComputer calculated custom scales are available, incorporating all temperature,pressure, density and viscosity variables.

• Custom scales can be produced for other liquids and gases, and fluids working at other temperatures and pressures.

FLO

WM

ETER

S

+43 1 706 43 000 21

Page 20: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Data Sheet DS1112

Specification

Product Codes

NG/LG SERIES GLASS VA FLOWMETER

• Easy to use

• Simple and reliable

• Gas or liquid flow measurement

• Operator confidence from float rotation

• Instantaneous response

• Air flow range 5 cm3/min to 150 L/min

• Typically 10:1 range

• Glass tube removal without tools

Backplate White polyester powder coated aluminium

End Blocks Brass or Stainless SteelSeals Nitrile with Brass end blocks Viton

with Stainless Steel end blocksSafety Cover Moulded PolycarbonateConnections 1/4" BSP Female, 1/4" NPT Female

optionalPressure Max 16 bar non-shock

• First choose tube from page 9 then choose frame size and connection

Connections Valve Material Size 1 Size 2 Size 3Rear facing No Brass FNGTB111A FNGTB211A FNGTB311ARear facing No SS FNGTS121A FNGTS221A FNGTS321ARear facing Yes Brass FNGVB111A FNGVB211A FNGVB311ARear facing Yes SS FNGVS121A FNGVS221A FNGVS321AIn-Line No Brass FNGIB111A FNGIB211A FNGIB311AIn-Line No SS FNGIS121A FNGIS221A FNGIS321A

• For 1/4" NPT thread change last digit of code to 2 (eg FNGTB112A)

Temperature Max Nitrile seals: 80°C Viton seals: 100°CNeedle Valve Flow control valve fitted

to NGV model only. Other models can use separate needle valve type FCV

Installation Vertical with flow upwards - read top of float

Dimensions 210 x 30 x 46.5mm depth (no valve)Rear Connection 184mm pitch

Improved for 2007, the NG & LG Series arelow cost frames for the standard 100mmscale or reduced 30mm scale glass tubes.Ideal for panel mounting. Both series aresupplied with mounting studs. Modelsavailable with in-line or rear-facing processconnections; the latter available with anoptional needle valve for flow control. Floatand scale visibility is improved through theuse of a clear polycarbonate cover setagainst a white background.

FLOW

METER

S

www.mess-regeltechnik.at22

Page 21: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Data Sheet DS1132

GR MINIATURE PLASTIC VA FLOWMETER

Specification

Product Codes

Plastic moulded VA Flowmeters with 50mmscale and rear facing connections. Suitable forflush panel or surface mounting, with orwithout flow control valve, for air or waterranges. Special integral flow guides stabilisethe float throughout the range to keep itfrom hunting or wandering in the bore. Thefloat is highly visible against a whitebackground. The direct reading scales eliminatetroublesome conversions. These low costflowmeters are ideal for general use.

• Low cost flow indication

• Air or water calibration

• Large 50mm scale

• Stainless Steel rear connections

• Adjustable set point indicator flag available on request

• Flow control valve option

Materials Polycarbonate flowtube. Stainless Steel connections. Neoprene/Buna N O-ringsConnections 1/8" NPT FemaleTemperature 55°C maxPressure 100psi maxInstallation Tube must be vertical with flow upwards - read centre line of float against scale Panel Cut Out 116 x 19mm mounting brackets supplied with meter

Air Ranges at ATP Standard Model Valved Model30 - 240 cm3/min FGR11 FGRV11 100 - 1000 cm3/min FGR13 FGRV13 200 - 2500 cm 3/min FGR14 FGRV14 0.5 - 5 L/min FGR20 FGRV20 1 - 10 L/min FGR21 FGRV21 2 - 25 L/min FGR22 FGRV22 10 - 100 L/min FGR25 FGRV25

Water Ranges at 20°C5 - 50 cm3/min FGR32 FGRV32 20 - 300 cm3/min FGR34 FGRV34

FLO

WM

ETER

S

+43 1 706 43 000 23

Page 22: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

Product Codes

SGUV SHUNT ORIFICE FLOWMETER

By introducing a standard sharp edge orifice plate between flanges in the line, a proportion of the main flow is diverted around the external pipework, through a locally mounted specially calibrated VA flowmeter. The flow through this shunt meter is linearly related to the line flow and is read directly on a linear scale.

• Easy installation between pipe flanges

• Instantaneous reading

• No electrical power needed

• Isolation valves for tube replacement and cleaning

• Option of GIR infrared alarms

• Designed to suit flange fittings (ANSI, DIN, BS10)

Material Stainless Steel plate mounted in Polyester coated steel carrier ringFlanges Standard BS10 Table EDP Produced 25" WG for air 100" WG for liquid flows (max)Thickness Standard 25mmValves Dual SS isolating valves fittedTube Borosilicate Glass, 100mm scalePiping Copper with plated Brass connectionsHousing Polyester coated die-cast Aluminium with perspex windowO-Ring Seals NitrileLimits 25 bar max, 80°C max

Flow RangeAir Flows at ATP Pipe Size Code30 - 150m3/hr 1 1/4" FSGUVB1A 40 - 200m3/hr 1 1/2" FSGUVB2A 80 - 400m3/hr 2" FSGUVB3A 180 - 900m3/hr 3" FSGUVB5A 5 - 25m3/min 4" FSGUVB6A

Water Flows at 20°C Pipe Size Code2 - 10m3/hr 1 1/4" FSGUVB1B 3 - 15m3/hr 1 1/2" FSGUVB2B 5 - 25m3/hr 2" FSGUVB3B 10 - 50m3/hr 3" FSGUVB5B 20 - 100m3/hr 4" FSGUVB6B

Shunt Orifice Flowmeters are direct reading flow measurement systems for clean liquids and gases in pipes from 1 1⁄4" to 24" diameter.

• Different process fluids or flow ranges

• Meters for line sizes up to 24"

• All Stainless Steel option available

• SGUL uses flexible PVC piping to install indicator at up to 25 feet away

FLOW

METER

S

www.mess-regeltechnik.at24

Data Sheet DS1160

Page 23: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

LPCB FIRE SPRINKLER FLOWMETER

Specification

Product Codes

Main Orifice Carrier 316 Stainless Steel flow orifice mounted in Polyester coated Carbon Steel carrier

Bypass Flow Indicator Nickel plated Copperimpulse pipe and Brassconnections

Connections Models for clamping between flanges or utilising approved groove couplings

Housing Polyester coated die-cast Aluminium with perspex window

Filter Unit 316 Stainless Steel elementinside TPX tube

Limits 12 bar max at 20°CPressure Test 30 bar hydraulicTube Borosilicate Glass 100mm scaleFloat Stainless SteelO-Ring Seals NitrileInstruction Read from top of float

Spacing requirement:Flange model = 40mm for all sizesGroove model = 90mm for 50, 80, 150mm sizesGroove model = 100mm for 200mm size

Flow Range(dm3/min) Nominal Size (mm)* Code (Flanged) Code (Grooved)150 - 750 50 FLPCB - F1/5 FLPCB - F1/10300 - 2300 80 FLPCB- F1/6 FLPCB - F1/11500 - 3500 100 FLPCB - F1/7 FLPCB - F1/12900 - 8200 150 FLPCB - F1/8 FLPCB - F1/132500 - 12500 200 FLPCB - F1/9 FLPCB - F1/14

* 50 -150mm to BS 1387, 200mm to BS3600

• Approved and listed by LPCB for automated sprinkler systems

• 150 - 12,500 dm3/min range

• Easy and quick installation

• Flanged or victaulic connections available

• Instantaneous reading

• Best in class flow ranges

• Isolation valves for tube replacement and cleaning

• Air bleed and drain valves

• Spare tube supplied

Approved and listed by the LossPrevention Certification Board, and

equivalent overseas authorities

The Shunt Gapmeter Model LPCB is approvedfor regular monitoring and testing of sprinklersystems by the LPCB (Loss Prevention CertificationBoard) under their ‘Rules for Automatic SprinklerInstallations’, in the UK, and by many equivalentorganisations in other countries.

Model LPCB provides a compact,robust, direct reading flowmeter for50mm-200mm pipelines and is suitablefor use in horizontal or vertical pipes.

FLO

WM

ETER

S

+43 1 706 43 000 25

Data Sheet DS1162

Page 24: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Scale Length 100mm typicallyOverall Length 140mmFlow Tube Material Borosilicate Glass with fused ceramic scaleFloat Material Duraluminium or Stainless Steel for gases; Stainless Steel for liquidsAccuracy: 1 Air: ±1.25% FSD Gases: ±3% FSD Water: ±1.25% FSDStandard Conditions 1.013 bar A & 20ºC (ATP)2

Suitable Frames NG & G series & GU typeInstallation Vertical with flow upward - read top of float

Notes1 FGTF 1CHD and FGTF 1BHD scales are specially calibrated for very low flow rates with an accuracy of ±2.5%FSD.2 Atmospheric temperature and pressure is abbreviated to ATP on Platon flowmeters. Custom scales for other

conditions are available. Unless requested, custom scale units will be expressed at ATP.

Specification

Product Codes

The Platon range of Glass Tube Flowmeters typically uses the 100mmscale length borosilicate glass tube and a float. Based on the well knownvariable area (VA) principle of flow measurement, these flowmetersprovide clear, simple and reliable operation.

Principle of Operation

Fluid flowing vertically upwards through the tapered glass tubecauses the float to rise to an equilibrium position. Flow rate ismeasured by reading the top edge of the float against the scaled tube(see diagram below).

Platon Glass Tubes from RM&C are individually scaled and calibratedaccording to customer’s requirements. Custom scales are producedusing our "Reynolds Curve" prediction software, which uses air orwater calibration data corrected for the effects of temperature andpressure on the density and viscosity of the working fluid.

• Instantaneous response

• Simple and relaible operation

• Low line pressure loss

• High resolution

• Custom scales available on request

Spare Glass Tube and Floats

CodeFGTF****-*FGTF3ASS-* (for gases)

Custom scales are supplied at no extra cost

For standard gas or water ranges, select the required flow range from the tableon page 11. To order, quote the Tube Code, with the Scale Code as a suffix. Unitscaled tubes, 1 to 10 linear units, are also available as standard. Quote therequired Tube Code with the suffix A.

Example: For a typical Argon flow of 3 L/min, choose the range 0.6 to 4 L/minand quote the code FGTF 2BHD-J.

100mm SCALE GLASS TUBE & FLOAT

FLOW

METER

S

www.mess-regeltechnik.at26

Page 25: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

How to Specify

Platon Glass VA Flowmeter Tubes are widelysupplied for use on medical equipment such asanaesthetic trolleys. Available in keyed lengthsand colour coded to avoid incorrectinstallation, standard tubes are calibrated foroxygen, nitrous oxide or air.

• Instantaneous response

• Reliable operation

• High visibility scale fused into flow tube surface

• Float rotation gives operator confidence of correct performance

• Borosilicate glass tube, anti-static coated to avoid static build up

• Flow ranges from 10:1 to 150:1 available

• Individual flow calibration

• Standard gases - air, oxygen, nitrous oxide

• Customised logo available

Glass Tube Borosilicate GlassFloat Red DuraluminiumScale Fused ceramic black inkTube Diameter O/D 12mm or 15mm nominalStandard Lengths 230/240/250/260mm (150mm to special order)Gases Oxygen, Nitrous Oxide, Air, Helium, Carbon Dioxide, CyclohexaneFlow Ranges 0.1 - 1.0 L/min

1.0 - 10 L/min0.1 - 15 L/min

Accuracy To specification requiredTypical ±2% FSD, ±10% reading or ±2.5mm

• Anaesthetic tubes are made to order• Contact our Technical Sales Team specifying the gas, flow range and tube length required for a specific product

and price quotation

ANAESTHETIC GLASS TUBE & FLOAT

FLO

WM

ETER

S

+43 1 706 43 000 27

Data Sheet DS1170

Page 26: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

Product Codes

GIR (FLOSCAN) INFRA-RED FLOW ALARM

Floscan Flow Alarms use an infra-red beam across theglass flowtube of a VA meter. Passage of the floatbetween the sensor arms is detected and logic withinthe electronics determines whether the float is aboveor below the sensor position. Clipped to the rear of theframe, the sensor can be adjusted up and down to therequired position. The sensor is 12Vdc powered with atransistor switch output to drive external logic circuits.A mains operated power unit and slave relay can beused to drive either one or two Floscan sensors.

• Optional Mains Interface Relay Module (see page 35)

• ATEX approved

Sensor Type IR Beam break detectionDirection Logic Position of float above/below

sensor established after firstdetection of float after power up

Setting Position Held by spring clip anywhere inflow tube operating range

Sensor Cable 2 metre, 3 core screenedCable Functions Red - Positive

Black - 0V CommonWhite - Transistor output

Voltage Supply 12V nominal, 8V - 26Vdc range at25mA

Temperature -5 to 50°C

Environment IP44 with cable exit downwards0utput Open collector transistor 50mA

30V max (sensor positioned opencircuit for low flow alarm, withcable exit down) conducts for flowabove switch point

Switch Points For falling float, top edge of float atcentre line of sensor. For risingfloat, switching occurs when baseof float passes centre line.

Dimensions H22 x W60 x D30, 4mm spaceneeded behind frame

Approval ATEX EEx ia IIC T4

Description CodeFloscan sensor for liquid applications FGIR*L Floscan sensor for gas applications FGIR*G Mains Relay (see page 35) F58384

Suitable for flowmeter housing:

• NGX/LGX Series (page 12-16)• GU to special order (page 17)• SGUV to special order (page 24)

• High or low flow alarm

• Intelligent: knows whether float is above or below the sensor

• Adjustable over full range of flowtube

• DC output direct to standard logic circuits

• Specify tube size 1, 2 or 3 at * in model code. GIR is not compatible with all old flowtubes. A new flowtube should be purchased with the GIR alarm

• May not be suitable for some liquid applications with gas bubbles or solids in medium.

• Not suitable for guided floats

Please contact our Technical Sales Team for details

FLOW

METER

S

www.mess-regeltechnik.at28

Data Sheet DS1120

Page 27: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

SPARES & ACCESSORIES

FLO

WM

ETER

S

Product Codes

Genuine Platon Spares & Accessories• A full range of accessories are available for your Glass Tube Flowmeters

• O-ring seals are available in Nitrile and Viton

Platon Flowmeter Accessory/Spare Part Description Ordering CodesNGX/LGX Bench Mount Stand F54108

NGX Valved Panel Mount Bezel FBEZELGTVNGX Non-Valved Panel Mount Bezel FBEZELGTBrass Adaptor to fit 1/4" BSP FCV (Fine Control Valve) F5842112Stainless Steel Adaptor to fit 1/4" BSP FCV (Fine Control Valve) F5842114Connection Hose Adaptors (pair) -

Brass 1/4" NB Hose to 1/4" BSP F5841303Stainless Steel 1/4" NB Hose to 1/4" BSP F5841313Brass 1/4" NB Hose to 3/8" BSP F5841305Stainless Steel 1/4" NB Hose to 3/8" BSP F5841315

Tube to insert O-rings (pack of 10)Size 1 Nitrile FK23004Size 1 Viton FK23000Size 2 Nitrile FK23007Size 2 Viton FK23001Size 3 Nitrile FK23026Size 3 Viton FK23036

Insert to end block O-rings (pack of 10)Nitrile FK23059Viton FK23045

GU Brass adaptor to fit 3/8" BSP FCV (Fine Control Valve) F5842124Stainless Steel adaptor to fit 3/8" BSP FCV (Fine Control Valve) F5842122

PG/PGU Tube to insert O-rings (pack of 10)Size 4 Nitrile FK23107Size 4 Viton FK23108Size 5 Nitrile FK23109Size 5 Viton FK23110

+43 1 706 43 000 29

FK23036

FK23045

F54108 F5841303

FK23000

F5841305

Page 28: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

GMT SERIES METAL TUBE VA FLOWMETER

Platon GMT Metal Tube Flowmeters are magneticallycoupled VA meters for liquids or gases. Fluid flowlifts the float assembly (with its encapsulatedmagnet) inside the tapered flow tube. The metersexternal pointer follows the magnetic field indicatingflow against a clear 150° scale, typically displaying a10:1 flow range.

High and low flow alarm versions are also available(see page 34). For full electronic transmission andtotalisation, utilising the vampire electronicmodule (see also page 34).

Its robust construction with noglands or seals makes the GMTideal for arduous service;particularly high pressureapplications or extremes oftemperature.

Custom scales can beproduced to suit otherflows and conditions.

Alternative material options suchas Hastelloy,Monel and PTFE-linedversions are available on request.

Please contact our Technical SalesTeam to discuss your application

FLOW

METER

S

It has particular advantages where opaque or stainingfluids would make glass tube flowmeters unsuitable.Available in standard sizes from 1/2" - 4", with Brass orStainless Steel bodies.

www.mess-regeltechnik.at30

Page 29: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

GMT SERIES METAL TUBE VA FLOWMETER

• Local mechanical installation

• No power required (local indicator)

• Clearly visible scale

• Scaled for process fluids

• Easy installation - flanged or screwed

• No glands or seals

• Robust, simple construction

• Pulsation damper on gas meter

• Alternative flanged or threaded options available

• Special body and indicator materials

• Optional alarms and transmitters (see page 34)

• Hygienic versions with triclamp connections

Please contact our Technical Sales Team to discuss your application

Principle of operationA permanent magnet encapsulated within thestainless steel float drives the externalmagnetically coupled pointer. Float movementis related to flow rate, and the indicator scale ismarked in the correct units of flow for theprocess conditions.

The standard unit requires no electrical power.As the measuring element is a sharp edgeddisc, the meter is relatively insensitive toviscosity changes in the fluid and to pipebends in the external pipework. The onlymoving part in the flow is the float which isretained in place by float guides at either endof the meter.

Specification

Sectioned model GMTXA313G

Options

FLO

WM

ETER

S

+43 1 706 43 000 31

Page 30: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

GMT FLANGED SERIES FLOWMETER

GMT flanged metal tube magnetically coupled variablearea flowmeter. Robust construction for heavy duty.Available in sizes 1/2" to 2" for gases, or 1/2" to 4" forliquid flows.

• Clearly visible scale

• Scaled for process media

• Easy installation - flanged

• No glands or seals

• Low pressure drop version available with PVC floats on 1/2" and 1" models

• Other options available

Specification

Product Codes - Low Pressure Drop Variants

Body Materials Stainless SteelFloat Stainless Steel or PVC on low

pressure drop unitsGuides Stainless SteelConnections Flanges DIN PN16 as standardOverall Length 250mm for 1/2" to 2" unitsIndicator Housing Aluminium, Polyester coatedProtection IP65Flow Range 10:1 typicalAccuracy ±2% FSDFlow Scale 100mm long, 150° typicalPressure 100 bar max or as flange rating

Temperature 200°C max (50°C on low pressure drop units)

Pulsation Damper On gas meters a dashpot smoothes out flow pulsations

Standard Conditions 1.013 bar A & 20°C (ATP)1

Installation Vertical with flow upwardApproval CRN.CSA-OF4812.26

1 Atmospheric temperature and pressure is abbreviated toATP on Platon flowmeters. Custom scales for otherconditions are available. Unless requested, custom scaleunits will be expressed at ATP.

1/2" or 15mm Pipe Size GAS - m3/hr Air @ATP0.5 - 5.0 FGMT111G0.75 - 7.5 FGMT112G1.2 - 12.0 FGMT113G1.8 - 18.0 FGMT114G

LIQUID - L/hr Water @20oC20 - 160 FGMT111L20 - 250 FGMT112L40 - 400 FGMT113L60 - 600 FGMT114L

1" or 25mm Pipe Size GAS - m3/hr Air @ATP 3 - 30 FGMT211G5 - 50 FGMT212G10 - 75 FGMT213G10 - 120 FGMT214G20 - 200 FGMT215G40 - 360 FGMT216G

LIQUID - m3/hr Water @20oC0.1 - 1.0 FGMT211L0.2 - 1.6 FGMT212L0.2 - 2.5 FGMT213L0.4 - 4.0 FGMT214L0.6 - 6.0 FGMT215L1.0 - 10.0 FGMT216L

2" or 50mm Pipe Size GAS - m3/hr Air @ATP 18 to 180 FGMT311G30 to 300 FGMT312G60 to 600 FGMT313G100 to 1000 FGMT314G

LIQUID - m3/hr Water @20oC0.6 - 6.0 FGMT311L1.0 - 10.0 FGMT312L2.0 - 16.0 FGMT313L2.0 - 25.0 FGMT314L

Product Codes

1/2" or 15mm pipe size 1" or 25mm pipe size GAS Pressure Loss GAS Pressure Loss m3/hr Air@ATP m bar m3/hr Air@ATP m bar 0.3-3.0 FGMT11AG 7 1.5-15 FGMT21AG 80.4-4.0 FGMT11BG 10 3.0-23 FGMT21BG 90.7-7.0 FGMT11CG 7 4.0-36 FGMT21CG 80.9-9.0 FGMT11DG 10 5.0-50 FGMT21DG 9

FLOW

METER

S

www.mess-regeltechnik.at32

Data Sheet DS1220

Page 31: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

GMT THREADED SERIES FLOWMETER

Specification

Product Codes

Body Materials GMTB - BrassGMTS - 316 Stainless Steel

Float Stainless Steel or PVC on low pressure drop units

Guides Stainless SteelIndicator Housing Aluminium Polyester coated,

weather-proofed to IP65Connections Screwed BSP Female or NPT

Female thread sizes 1/2", 1", 2"Scale Length 100mm 150° typical

Overall Length 250mmStandard Conditions 1.013 bar A & 20oC (ATP)Flow Range 10:1 typicalTurndown Typically 10:1Accuracy ±2% FSDHysteresis Less than 0.5%Pressure GMTB: 75 bar, GMTS: 100 barTemperature 200°C max (50°C on low

pressure drop units)Approvals CRN.CSA-OF4812.26

(stainless steel only)

1/2" BSPP FemaleGAS - m3/hr Air @ATP0.5 - 5.0 FGMT*151G0.75 - 7.5 FGMT*152G1.2 - 12.0 FGMT*153G1.8 - 18.0 FGMT*154G

LIQUID - L/hr Water @20°C20 - 160 FGMT*151L20 - 250 FGMT*152L40 - 400 FGMT*153L60 - 600 FGMT*154L

1" BSPP FemaleGAS - m3/hr Air @ATP3 - 30 FGMT*251G5 - 50 FGMT*252G10 - 75 FGMT*253G10 - 120 FGMT*254G20 - 200 FGMT*255G

LIQUID - m3/hr Water @20°C0.1 - 1.0 FGMT*251L0.2 - 1.6 FGMT*252L0.3 - 2.5 FGMT*253L0.4 - 4.0 FGMT*254L0.6 -6.0 FGMT*255L

2" BSPP FemaleGAS - m3/hr Air @ATP18 to 180 FGMT*351G30 to 300 FGMT*352G60 to 600 FGMT*353G100 to 1000 FGMT*354G

LIQUID - m3/hr Water @20°C0.6 - 6.0 FGMT*351L1.0 - 10.0 FGMT*352L2.0 - 16.0 FGMT*353L2.0 - 25.0 FGMT*354L

GMT screwed metal tube magnetically coupled VAflowmeter. Robust construction for heavy duty. Availablein sizes 1/2" to 2" for gas and liquid flow.

• Brass or stainless steel body

• Economic construction

• BSP/NPT screwed end process connections

• Wide flow ranges

• Pulsation damper fitted as standard on gas meters to stabilise reading

• Calibration for wide range of gases and liquids

• Low pressure drop versions available with PVC floats on 1/2" and 1" models typically for use with Natural Gas.

1/2" or 15mm pipe size 1" or 25mm pipe size GAS Pressure Loss GAS Pressure Loss m3/hr Air@ATP m bar m3/hr Air@ATP m bar 0.3-3.0 FGMT*15AG 7 1.5-15 FGMT*25AG 80.4-4.0 FGMT*15BG 10 3.0-23 FGMT*25BG 90.7-7.0 FGMT*15CG 7 4.0-36 FGMT*25CG 80.9-9.0 FGMT*15DG 10 5.0-50 FGMT*25DG 9

Product Codes - Low Pressure Drop Variants

FLO

WM

ETER

S

+43 1 706 43 000 33

Data Sheet DS1221

Page 32: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification - GMTX Transmitter

Flow ranges Functions with any GMT flowtube flanged or screwed

Display Liquid crystal panelAnalogue scale 10%-100%, 90mm longDigital display 4 1/2" digit display, 10mm high, in

flow units, selectable for flow rate or total

Flow alarms High and low flow alarmAccuracy ± 1% Flow rig calibrated

Housing IP65 Polyester coated aluminium Model GMTXA Power 85-265VacOutput 4-20mA into 600ohm maxAlarms 2 x 8A SPCO relaysModel GMTXD 20mA loop powered CENELEC

approved unitSupply volts 12Vdc minimumAlarms 2 x open collector transistorApproval EExia IIB T4

GMT SERIES TRANSMITTER/ALARM OPTIONS

Specification - GMTA/GMTAA Alarm

GMTX (Vampire) is an electronic version of the standard GMT metal tube flowmeter,where the mechanical pointer and scale is replaced with an LCD to give local meter anddigital display of flow rate and flow total. The totally solid state indicator is either looppowered, or mains AC powered with a 4-20mA output. High and low alarms are shownon the liquid crystal display panel, and can be signalled to the plant control system.

• Alarms for high and low flow

• CENELEC approved loop powered unit for hazardous areas

• Gas or liquid flows

• 1/2" to 4" line size

• Monitoring process total demand

• Control room monitoring of process flows

• Interface to chart recorders

• Electronic output for plant control

• Rate and total display in flow units

SensorType coding DIN 19 234 (NAMUR)Type number SJ2 - NApproval EExia IIC T6IP Rating IP67Connection 2m screened cable (2 cores)

Control UnitPower supply 115v or 230Vac or 24Vdc modelsOutput SPCO Relay 2 Amp at 250V or 40Vdc

Selectable energised/de-energised for alarmEnvironment IP20, from -20ºC to 60ºCIndicators Green LED power on

Red LED sensor lead brokenYellow LED relay energised

Approval (EExia)Size 115 x 118 x 20Mounting 35mm DIN rail or screw fixing

Product Codes - Interface Modules for Alarm Units

For units fitted with alarms and transmitter versions, insert the appropriate code from below before the first number in your selectedcode from pages 32 and 33. Example: For the model FGMT113L to be fitted with dual alarms, the code becomes FGMTAA113L.

Description Code Description Code Single channel Alarm A Single channel, 110Vac supply F6001622Dual channel Alarm AA Single channel, 220Vac supply F6001623AC powered transmitter XA Single channel, 24Vdc supply F6001626DC powered transmitter XD Dual channel, 110Vac supply F6001624Dual channel, 24Vdc supply F6001627 Dual channel, 220Vac supply F6001625

FLOW

METER

S

www.mess-regeltechnik.at34

Data Sheets GMTX DS1225 • GMTA DS1220

Page 33: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

MAINS INTERFACE RELAY MODULE

Specification

Product Codes

The Floscan Mains Interface Relay Module is a DIN rail/surface mounted unit thatprovides DC power for one or two GIR (Floscan) Infra-red flow alarm sensors (page28), from any mains power source. Each sensor output drives a relay in the module,allowing external signalling via the 8 Amp voltage free relay contacts. The twoFloscan sensors can be high or low flow alarms (dictated by the sensor orientation)

• High or low flow alarm

• Intelligent: knows whether float is above or below the sensor

• LED indicators

• SPCO relay outputs

• DIN rail mountable

Mains Power Input 20 - 256 Vac, 50/60Hz, 24 - 370 VdcSensor Power Output +12Vdc, 120mA (suitable for GIR Alarm modules) +24Vdc, 25mA (suitable for GMTXD

transmitter)Floscan Inputs Two channel input, independentRelay Output 8 Amp, 250Vac max de-energised for sensor output open circuit, SPCO actionLEDs Green LEDs for no alarm, (relays energised);Yellow LED for power on; Red LEDs to indicate

that float position is unknown (occurs on switch on before float first passes sensor)Temperature -5° to +50°CDimensions 70 x 75 x 112mm high

Description CodeFloscan Mains Interface Relay Module F58384

and can be on the sameflowmeter tube, or on separateflowmeters. Energised relaynormal conditions are displayedby LED indicators. The modulecan also be used to power andmonitor alarm outputs from theGMTXD Transmitter (page 34).

FLO

WM

ETER

S

+43 1 706 43 000 35

Data Sheet DS1120

Page 34: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

How to Specify

VARIABLE ORIFICE/SWING VANE

Manufactured in a wide range of sizes and specification options but all having thesame basic function. A dial and mechanical indicator continuously monitor the flowrate, whilst electrical switches can be specified to signal when a particular level hasbeen reached during increasing or decreasing flows. Switches are field adjustableover the full range. Where batching, trending, totalisation or recording is required, allunits can be supplied with a 0-10V or 4-20mA output.

• Suitable for gas and liquid applications

• Spring loaded mechanical design - requires no straight pipe run and not affected by orientation

• Modular design - reduces maintenance costs, down time and production loss

• 1% of rate repeatable switch set point - accurate & reliable through all operation cycles

• Individually calibrated to customer specification - ensures accuracy

• ATEX certified explosion proof switches available

• Available in various metals or plastics

The flow switch body houses a spring loaded valve plate (vane) which pivots off-centre in a hemispherical cavity.Thus, the vane and cavity have a variable area orifice relationship. This gives both a high flow range and a linearrelationship between flow rate and vane displacement. The vane indirectly operates both the indicating needleand an adjustable cam, which in turn triggers the micro-switch at any chosen setting of flow-rate. Two switches canbe supplied to provide high and low (or low-low) flow switching.

• Fluid/viscosity/density/specific gravity

• Flow range & units

• Operating temperature & pressure

• Maximum volume flow

• Pipe size & connection

• Body & seal material

• Switch/output requirements

• Special requirements

• Water (clean & dirty)

• Water (de-ionised)

• Water (de-mineralised)

• Petroleum/synthetic based oils

• Solvents

• Paints

• Corrosive fluids

• Air & Gases

• Coolants

Please provide the following information to defineyour requirements:

FLOW

METER

S

www.mess-regeltechnik.at36

Applications:

Page 35: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

FLOWMETERS

Specification Specification

Platon AP PurgemeterFor monitoring low flow rates of highpressure liquids or gases, or whereglass tubes are not suitable,purgemeters are Stainless Steel inconstruction with a magneticallycoupled pointer. They provide directflow indication and can be fittedwith flow control valves.

Data Sheet DS1210Flow tube 316 Stainless SteelEnd Blocks Stainless Steel Float Stainless Steel for liquid,

Aluminium for gasesO-Ring Seals VitonMeter Housing Aluminium, black anodised body

Polycarbonate windowProtection IP65Accuracy VDE/VDI Class 6Fluid Temperature -20° to 150°CFluid Pressure 40 bar max APV

100 bar max APT/APIConnections 1/4" NPT FemaleInstallation Vertical with flow upwardsApproval CRN.CSA-OF4812.26

Typical Typical Water Flow Air Flow (ATP)L/hr L/hr Standard Valved In-line1 - 10 30 - 250 FAPTS 3211* FAPVS 3211* FAPIS3211*2 - 16 40 - 400 FAPTS 4211* FAPVS 4211* FAPIS4211*3 - 25 60 - 600 FAPTS 5211* FAPVS 5211* FAPIS5211*4 - 40 100 - 1000 FAPTS 6211* FAPVS 6211* FAPIS6211*6 - 60 160 - 1600 FAPTS 7211* FAPVS 7211* FAPIS7211*

* Suffix L for Liquid, G for Gas• Please enquire for flow ranges for alternative fluids

or for higher pressure gases

GPI Digital Liquid TurbinesWide range of economical modularturbine flowmeters, available in avariety of connection sizes andmaterials. Battery powered digitaldisplay requires no external power.

Connections 1/2" - 2" NPT or BSPTFlow Ranges 4-760 L/minAccuracy Down to ±0.75% of readingMaterial Options Nylon/Aluminium/Stainless Steel

Brass/PVC/PVDF Power Lithium batteries suitable

for 2000 hours of LCD displayExternal power module available (Auto powers off when not in use)

Temperature Range -40°C to + 120°CDisplay Local or remote mountTotaliser 4-20mA/pulse output available

How to SpecifyProduct Codes

FLO

WM

ETER

S

Please contact our Technical Sales Team to discuss your

application

+43 1 706 43 000 37

Data Sheet DS1210

Page 36: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification Specification

FLOWMETERS

Connections BSP FemaleBody Nickel Plated Brass CZ114Accuracy ±5% FSDRepeatability ±1% FSDRangeability 10 - 100% FSDPressure 350 bar maxTemperature 90°C maxCalibration Oil (SG 0.856) at 20°C

Water at 20°C

• Works in any orientation

• Pressure up to 350 bar (5000 psi)

• Accuracy ±5% FSD

• Repeatability ±1% FSD

• Direct reading

• Relatively insensitive to viscosity changes

• Oil or water calibrated

Compressed AirThese metal bodied flowmetersoperate using a spring loaded orificemoving over a tapered cone, toachieve a variable area meter. Flow isindicated by a magnetic follower ringunder a scale on an external glasstube.

• Calibrated for direct reading of compressed air at 7 bar and 20°C

• Works in any orientation

• Brass, Stainless Steel or Aluminium models available in 5 sizes

• Pressures up to 41 bar (600 psi)

Flow BSP Length Water Oil Range Conns (mm) Code Code(L/min)0.2 - 2 1/4" 123 FFLW111 FFLL111 0.5 - 4.5 1/4" 123 FFLW121 FFLL121 1 - 9 1/4" 123 FFLW131 FFLL131 2 - 20 1/2" 166 FFLW211 FFLL211 5 - 46 1/2" 166 FFLW221 FFLL221 5 - 55 3/4" 190 FFLW311 FFLL311 10 - 100 3/4" 190 FFLW321 FFLL321

High Pressure LiquidThese metal bodied flowmetersoperate using a spring loaded orificemoving over a tapered cone, toachieve a variable area meter. Flow isindicated by a magnetic followerring under a scale on an externalglass tube. The flow reading isindependent of viscosity up to 200 cs.

Connections BSP FemaleBody Nickel Plated Brass CZ114Accuracy ±5% FSDRepeatability ±1% FSDRangeability 10 -100% FSDPressure 41 bar maxTemperature 90°C maxCalibration at 7 bar, 20°C

Flow @ 7 bar G BSP Length CodeRanges (L/sec) Conns (mm)(SCFM)2 - 20 1 - 10 1/4" 123 FFLA111 5 - 50 2 - 25 1/2" 166 FFLA211 10 - 100 5 - 50 1/2" 166 FFLA22115 - 125 6 - 60 3/4" 190 FFLA311 20 - 225 10 -100 3/4" 190 FFLA321

Product CodesProduct Codes

FLOW

METER

S

www.mess-regeltechnik.at38

Page 37: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

EPW OIL & WATER FLOWMETER

Specification

Product Codes

A spring loaded variable orifice meter which can bemounted in any orientation. Oil or water flow moves theorifice along a scale printed on the borosilicate glasstube, to indicate flow rate. Independent of viscositychanges up to 200 cs.

The meter body is in polyester with standard 1" BSPthreads.

• Oil and water calibrated

• Works in any orientation

• Pressures up to 10 bar

• Flows 1 to 150 L/min

• Accuracy ±5% FSD

• Repeatability ±1% FSD

• Switches - fully adjustable flow rate signalling

• Plant and equipment protection

Connections 1" BSP FemaleDimensions Length 196mm, Diameter 60mmBody Polyester and Borosilicate GlassAccuracy ±5% FSDPressure 10 bar maxTemperature +5°C to +80°C - oil; +5°C to +60°C - waterElectrical switch option Adjustable 20% -100% full scale

Water Flow (20°C) Meter Alone with AC /DC Switch1 - 15 L/min FEFW0152 FEFW0152B2 - 30 L/min FEFW0302 FEFW0302B4 - 50 L/min FEFW0502 FEFW0502B5 - 100 L/min FEFW1002 FEFW1002B10 - 150 L/min FEFW1502 FEFW1502B

Oil Flow (SG 0.856) (20°C)1 - 15 L/min FEFL0151 FEFL0151B2 - 30 L/min FEFL0301 FEFL0301B4 - 50 L/min FEFL0501 FEFL0501B5 - 100 L/min FEFL1001 FEFL1001B10 - 150 L/min FEFL1501 FEFL1501B

• The external alarm circuit should provide latching functions

FLO

WM

ETER

S

+43 1 706 43 000 39

Page 38: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

Product Codes

STAINLESS STEEL TURBINE & PELTON WHEEL

Accuracy NT & BNO ±0.5%NS ±1%

Repeatability NT & BNO ±0.1%NS ±0.25%

Output Sinusoidal pulses, 50 to 800mVElectrical Connections 2-way Amphenol connectorPressure Drop 0.2 to 0.5 bar, depending

on meter sizeTemperature 150°C max (high temp

versions available)

Pressure 300 bar maxWetted Materials Stainless Steel, Tungsten

Carbide & Carbon filled PTFE (NS Series includes a Butyl rubber O-ring)

NS and NT Series screwed models are also available withflanges, and BNO Series meters with RJT and ISS hygienictype fittings. Spare pick-up coils are also available.Please consult our Technical Sales Team.

Process Flow Range (Pulses/ CodeConnections (L/min) Litre)

NT Series Turbine Flowmeters3/8"BSP Male 0.5 - 5 17000 FFTB00121/2" BSP Male 1.2 - 10 5900 FNT51/2" BSP Male 2 - 20 3000 FNT71/2" BSP Male 5 - 50 2600 FNT113/4" BSP Male 8 - 80 1950 FNT131" BSP Male 15 - 150 630 FNT191" BSP Male 25 - 250 350 FNT2411⁄2" BSP Male 65 - 650 117 FNT382" BSP Male 110 - 1100 67 FNT48NS Series Pelton Wheel Flowmeters3/4" BSP Male 0.18 - 1.8 20700 FFTB00043/4" BSP Male 0.45 - 3.2 14500 FFTB00053/4" BSP Male 1.1 - 5.4 12500 FFTB00063/4" BSP Male 1.3 - 6.5 10500 FFTB0007

Process Flow Range (Pulses/ CodeConnections (L/min) Litre)

21⁄2" ANSI 150 Flanges 200 - 2000 18 FFTB00083" ANSI 150 Flanges 300 - 3000 14 FFTB00094" ANSI 150 Flanges 500 - 5000 7.5 FFTB00106" ANSI 150 Flanges 1000 - 10000 3.4 FFTB0011BNO Series Hygienic Flowmeters1/2" Tri-clamp 2 - 20 2800 FFTB00131" Tri-clamp 9 - 90 1000 FBNO5001" Tri-clamp 18 - 180 330 FBNO100011⁄2" Tri-clamp 25 - 250 240 FBNO15002" Tri-clamp 65 - 650 90 FBNO36

A range of Stainless Steel turbine flowmeters capable ofmeasuring flow rates of water and low to medium viscosityoils and other liquids in high pressure applications.Providing an electrical pulse output, these meters whenlinked to a display unit provide accurate and highrepeatability flow measurement.

The NS Series utilises the Pelton Wheel principle to provideaccurate flow measurement down to 0.18 L/min. Highaccuracy measurement is provided by the NT Series for upto 6" lines. For hygienic applications, the BNO series offersthe same high accuracy, in a ‘bug-trap’ free design. Stemmounted displays are available on page 41.

• Flow rates from 0.18 - 10000 L/min

• High accuracy/excellent reliability

• Industrial & hygienic versions

• Wide range of end connections available

• Now available for gas applications

• Reverse and dual pick-up options available on request

FLOW

METER

S

www.mess-regeltechnik.at40

Page 39: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

DIGITAL INDICATORS

Specification

Product Codes

• Units are also available mounted directly to the Turbine Liquid Flowmeters on page 40

• These units are also available in intrinsically safe and panel mounted versions

The FW Series of digital indicators is speciallydesigned for computing and displayingtotal and instantaneous flow rates in liquidor gas applications. Versions are availablefor either pulse or analogue inputs, and abatch controller is available for pulse inputs.Housed within a rugged, powder-coated aluminium enclosure that is suitable for directmounting to a flowmeter, pipe, wall or panel.

Display Large 40 x 90mm LCD with 7 x 17mm digits & 11 x 8mm digitsFlow - up to 7 digits, Total - 7 digits, Accum. Total - 11 digits

Programming Via keypadData Protection 10 year data retention minimum (total stored at 10 min intervals)Input: Pulse Sine wave, NPN/PNP open collector, reed-switch or NAMUR 0 to 10kHz

(selectable de-bounce for low frequencies)Analogue 4-20mA or 0 to 10Vdc with linear or square-root functions

Outputs: Pulse Open collector output, scaleable pulse per unit, 20Hz max, 50Vdc, 300mA max,25 or 100msec pulse width

Analogue Passive 4-20mAPower Supply 7 year lithium battery (4-20mA loop or 5 to 24Vdc, if required)Temperature -15ºC to 60ºCHousing UV resistant powder-coated Aluminium casing, SS bolts, Polycarbonate window,

EPDM, and PE sealsProtection IP67 (IP65 when panel mounted)Dimensions 130 x 114 x 58mmPanel Cut-Out 115 x 96mm (L x H)Cable Entry 1 x M20 and 2 x Pg9 cable glandsBatcher Outputs Two open collector outputs for one/two stage control 50Vdc, 300mA maxOverrun Correction AutomaticRemote Input One input for Start/Stop batchAlarm Unit Outputs: 2 x open collector outputs programmable as high/low alarms or pulse

output 50Vdc, 300mA maxRemote Input Reset of total quantity or batch totalRelays/Supply 12 to 24Vac/dc or 80 to 240Vac supply

Relays: 250Vac/1A maxSensor supply: 8.1 to 24Vdc, 80mA max @24V

Serial Comms RS232/RS485

Description CodePulse input 4-20mA output FDIS0090Pulse input with High/Low alarms FDIS0091Pulse input with 15-point linearisation FDIS0092Dual pulse input (no outputs) FDIS0093

Description CodeDual pulse input with ratio function FDIS0094Dual pulse input with A-B or A+B functions FDIS0095Pulse input Batch Controller FDIS0096

FLO

WM

ETER

S

+43 1 706 43 000 41

Page 40: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification - Model 910 Transmitter

How to Specify

MODEL 910 ELECTROMAGNETIC FLOWMETER

• Highly accurate

• No moving parts in the flow profile

• Configuration data is backed up and can be recovered

• Datalogging function

• Diagnostic facility

Min. Media Electrical Conductivity ≥5 µS/cm / ≥20 µS/cm for demineralised waterFlow Range 0.1 to 10 m/sAccuracy 0.5% (0.5 to 10 m/s) of reading value, 1% (0.1 to 0.5 m/s) of reading valuePower Supply 95 to 250 Vac 50/60 Hz (+10%, -15%) 12,14, 48 Vac/dc (Model 910E)(115/230V/24V D Model 910)Power Consumption 10 VAOutputs • Frequency 0 to 12 kHz with programmable flowrate and function

• Pulse 0 to 50 Hz with programmable volume, function and pulse width• Relay contacts 100V/0.5A with programmable function (as option)• Current 4 to 20 mA with programmable flowrate and function Max 500 Ω

Input Digital input with programmable functionCommunication RS485, RS232Control RS485, RS232, keyboard and magnetic pointer (MAG910E RS232)Electronics Protection Standard IP67/ Nema 5 (IP68/Nema 6 optional)Housing Material Cast AluminiumFlow Direction Bi-directional measurementDiagnostics Diagnostic of internal temperature and power supply voltagesReal Time Real time circuit for dataloggingDatalogger • Datalogger memory up to 15000 values (programmable sample rate)

• Registration of minimum and maximum flowrate including date and timeHazardous Area Approval Zone 2 pendingControl Principle Pulsed DC from transmitterCable Terminals 2 pieces PG11

Flange Steel 1.0402 or higherNominal Size 10 .. 800mmMaximum Nominal Pressure 1.0 MPa - 2.5 MPa (10,16,25 bar)Max Media Temperature 70oC (158oF) for hard rubber liner

130oC (266oF) for PTFE liner in remote versionAmbient Temperature -20 to 60oC (-4 to 140oF)Sensor Protection Standard IP67/Nema 5 (IP68/Nema 6 optional)Liner Hard rubber, PTFEMeasuring Tube Stainless Steel 1.4201, dimensions according to DIN 17457Hazardous Area Approval Zone 2 pendingOuter Casting Carbon Steel as standardExternal Coating Lacquered finish (anticorrosive)Conformity requirements PED according to directive 97/23/ECElectrode MAG910 Cr Ni, ST-ST 1.4571 Hastelloy C276 (Mag910E option=Tantalum)

Please contact our Technical Sales Team to discuss your application

The Model 910 Electromagnetic Flowmeter is an instrument designed formeasuring and indicating flow and total volume of conducting liquids. It boasts

Specification - Model 910 Sensor

diagnostic, real time and data loggingfeatures. The flowmeter is available in bothcompact and remote mount versions.FLO

WM

ETERS

www.mess-regeltechnik.at42

Page 41: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

MAG X1 ELECTROMAGNETIC FLOWMETER

Specification

Items Possible optionsAnalogue output 4-20mA current output signal moduleOption 1 0-10 V voltage output signal moduleAnalogue output Frequency output moduleOption 2Analogue output Binary in/output module (1x input signal for batching + 2x output signal)Option 3Communication options RS232 communication module, including cable

USB communication module, including cableIRDA wireless infra-red communication transmitter module, max. distance 2mWireless communication module (antenna), max. distance 20m indoor, 100m in open space, including receiver with USB connectionRS485 communication module, max. distance up to 1kmTCP/IP communication module, distance practically unrestricted (as given by TCP/IP technology), amplifiers might be necessary

Data-logger Memory/Data-logger module, 1MB capacity; 5 minute average flow-ratesampling intervals; 12-month data capacity

Real Time Clock Real Time Clock (RTC) module, current date and time

The MagX1 flowmeter has an advantage over conventional electromagnetictechnologies in that the sensor element converts the sensed signal into digitalformat. This enables the signal to be transmitted over much longer distances (up to500 metres) than possible with analogue transmission. The sensor also has anautomatic self-diagnosis feature which allows any sensor problems to be reportedon the transmitter display.

• Digital signal for remote transmission

• Self-diagnostic tool for sensor

• Indicative temperature measurement and automatic temperature compensation

• Empty pipe detection

• Sensor ingress protection of IP67 (compact) or IP68 (remote)

How to Specify

Please contact our Technical Sales Team to discuss your application

FLO

WM

ETER

S

+43 1 706 43 000 43

Page 42: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

MODEL 220 PORTABLE ULTRASONIC FLOWMETER

This portable device has been designed to meet the needs of theService/Maintenance and Commissioning Engineer who wishes to check the flow rateof liquids at different locations in the plant. The set-up of the unit is simple and userfriendly with the required flow information obtained in minutes.

• Portable dual mode flowmeter

• Easy to install clamp-on sensors withno process interruption

• Non-invasive flow measurement of liquids, no pipeline disturbance or pressure loss

• Suitable for all commonly used pipematerials with pipe diameters from 6mm to 6.5m (1/4" to 256")

• Integrated wall thickness measurement

• 2 flow channels as standard

Measuring Principle Ultrasonic time difference correlation principle and Doppler-NoiseTrek™Flow Velocity Range 0.01 - 25 m/sResolution 0.25 mm/sRepeatibility 0.15% of measured value ± 0.01 m/sAccuracy:

Volume Flow ± 1 - 3% of measured value depending on application,± 0.5% of measured value with process calibration

Flow Velocity ± 0.5% of measured valueRangeability 1/2500 Turn-down Ratio 1/100Measurable Liquids All acoustically conductive liquids with a gas or solid content of < 10% of volume

The ultrasonic sensors are clampedonto the outside of the pipe, thuseliminating the need to dismantle thepipework and interrupt the process.

How to Specify

Please contact our Technical Sales Team to discuss your application for Models 220, 110 and 160

FLOW

METER

S

www.mess-regeltechnik.at44

Page 43: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

FIELD MOUNT ULTRASONIC FLOWMETERS

Measuring Principle Ultrasonic time differencecorrelation principle

Flow Velocity Range 0.01 - 25 m/sResolution 0.25 cm/sRepeatibility 0.15% of measured

value ± 0.01 m/sAccuracy:

Volume Flow ± 1 - 3% of measured value depending on application,± 0.5% of measured value with process calibration

Flow Velocity ± 0.5% of measured valueTurn down Ratio 1/100Gaseous and solidcontent of medium < 10% of volume

Ultrasonic Flowmeter Model 160The field transmitter has beendesigned for permanent installationsin potentially explosive atmospheresand for field application with harshenvironmental conditions. Openingthe enclosure is not necessary forinstrument set-up and operation. Aseparate hand-held remote control orlaptop computer is not required. Theultrasonic sensors are clamped ontothe outside of the pipe,thus eliminatingthe need to dismantle the pipeworkand interrupt the process.

• Dual mode flow transmitter

• Non-invasive flow measurement of liquids, no pipeline disturbance, no pressure loss

• Suitable for all commonly used pipe materials with pipe diameters from 10mm to 3m (2/5" to 118")

• 1 or 2 flow channels,IP 66 field enclosure

• ATEX certified for hazardous areas Zone 1&2 EEx DE 2CT6

Measuring Principle Ultrasonic transit-time correlationprinciple and Doppler-NoiseTrek™

Flow Velocity Range 0.01 - 25 m/sResolution 0.25 cm/sRepeatibility 0.15% of measured

value ± 0.01 m/sAccuracy:

Volume Flow ± 1 - 3% of measured value depending on application,± 0.5% ± 1.0 cm/s of measured value with process calibration

Flow Velocity ± 0.5% ± 1.0 cm/s of measured value

Rangeability 1/2500 Turn down Ratio 1/100Gaseous and solidcontent of medium < 10% of volume

Specification Specification

Ultrasonic Flowmeter Model 110The field mounted flow transmittercan be configured via the keypadwithout any additional programmingdevices and is available as a singlechannel unit. The ultrasonic sensorsare clamped onto the outside of thepipe, thus eliminating the need todismantle the pipework and interruptthe process.

• Ultrasonic flowmeter in IP66 wall mounted enclosure

• Easy to install clamp-on sensors with no process interruption

• Non-invasive flow measurement of liquids, no pipeline disturbance, no pressure loss

• Suitable for all commonly used pipe materials with pipe diametersfrom 10mm to 2.5m (1/2" to 100")

FLO

WM

ETER

S

+43 1 706 43 000 45

Page 44: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

ULTRASONIC FLOWMETER/SWITCH

Solid state flow switch provides a highly accurate monitoring and control solution forwater-based fluids. Our UQS7 combines two built-in switchpoints, a 4-20mAanalogue output, and a digital display in a single, compact unit. Ultrasonic sensingtechnology measures time of flight between two discrete points, assuring highlyaccurate measurement with low insertion loss as compared to other types of flowsensor. Setpoints and dead-band are easily adjusted by using a built-in, user-friendly menu. Analogue output is scalable from 25% to 100% of full scale range,providing a high degree of flexibility for a wide range of applications. A 10 -bitmicroprocessor provides built-in self diagnostics and allows for switch time delays upto 9.9 seconds. For applications requiring accurate monitoring of water-based fluids,the UQS7 is an ideal choice.

• Integrated 4-20mA analogue output

• Easy to read LED display

• Fully configurable via keypad

• Suitable for water-based fluids

• IP 65 protection

• 7 digit LED display

• Tamper-proof keypad lock

• Rotable display

FeaturesFLO

WM

ETERS

www.mess-regeltechnik.at46

Page 45: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

ULTRASONIC FLOWMETER/SWITCH

Specification

Product Codes

Sensor Element Ultrasonic sensorMedia Water and similar media Digital Display 4-digit 7-segment LED-display

max. pressure 360 psi (25 bar) height 0.5 in., red(higher pressures on request) Display Rate 500 mS

Materials Error Display LED yellow and alphanumeric display,Wetted parts Brass (diagnosis function acc.DESINA®Housing (Electronics) Aluminum die-cast Power Consumption appr.50 mA (without load)Seals (Media) Klingersil® Analogue OutputPushbuttons Polyester Scanning Rate 500mSOperating Elements 3 easy responses pushbuttons Resolution 10 bit (1024 steps per measuring span)Protection/Class IP65 Current Output 4-20 mAPressure Connection 3/4, 1, 1 1/4, 2 BSPP Load max. RI = (Ub-12V)/20 mADimensions 3.9in x 4.3in (UQS7-10) RI=600 Ohm at Ub=24 VdcMeasure Ranges Load Influence 0.3%/100 Ohmsg/min 2.6/6.6/10.5/26.4/44.9 OptionsL/min (10/25/40/100/170) Voltage Output 0 to 10 VdcLinearity Error ±2.5% f.s. at 77ºF (+25ºC) Rating max. 10 mA, short circuit-proofA/D-Connector Adjustment Range 25% to 100% f.s.Scanning Rate 500 ms (for peak value memory) Switching Output(s)Electrical Connection Plug M 12 x 1, 5-pin, Switching Function Normally open/normally closed,

DESINA® conformity -(adjustable) standard/windows-modeTemperature Influence ±0.2% f.s./10K Adjustment Range 0% to 125% f.s.Compensation Range 14ºF to 158ºF (-10º to +70ºC) Hysteresis 0% to 125% f.s.Repeatability ±0.1% f.s. Diagnosis Function SP2 (DESINA® model)Temperature Range 39ºF to 266ºF Switching Frequenccy max. 100HzElectronics 14ºF to 158ºF Rating max. 500 mA, short circuit-proofStorage -22ºF to 176ºF Delay 0.0 to 9.9 s adjustableInlet-Outflow Zone Integrated in the measuring device Status Display(s) LED(s) greenPower Supply 15-32 Vdc,reversed polarity protected Options Electrical plug, adapters

Flow Rate Process Switch Analogue Output DESINA®Model (L/min) DIM “A” DIM “B” Connection Points (4-20mA) Signal

FUQS7-10-G3-2 .04 to 10 4.3 (110) 3.9 (100) G 3/4 BSPP 2 n/a 1FUQS7-10-G3-3 .0.4 to 10 4.3 (110) 3.9 (100) G 3/4 BSPP 2 YES n/aFUQS7-25-G3-2 .1 to 25 4.3 (110) 3.9 (100) G 3/4 BSPP 2 n/a 1FUQS7-25-G3-3 .1 to 25 4.3 (110) 3.9 (100) G 3/4 BSPP 2 YES n/aFUQS7-40-G4-2 .16 to 40 7.5 (190) 3.9 (100) G1 BSPP 2 n/a 1FUQS7-40-G4-3 .16 to 40 7.5 (190) 3.9 (100) G1 BSPP 2 YES n/aFUQS7-100-G5-2 .4 to 100 10.2 (260) 5.1 (130) G 1-1/4 BSPP 2 n/a 1FUQS7-100-G5-3 .4 to 100 10.2 (260) 5.1 (130) G 1-1/4BSPP YES n/aFUQS7-170-G8-2 .4 to 170 11.8 (300) 5.3 (135) G2 BSPP 2 n/a 1FUQS7-170-G8-3 .4 to 170 11.8 (300) 5.3 (135) G2 BSPP 2 YES n/a

AccessoriesMating electrical connector (not included) F239263

NotesStandard flow ranges x2 available at 3% FSD

FLO

WM

ETER

S

+43 1 706 43 000 47

Page 46: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Data Sheet DS1731

Specification

Product Codes

LAMINAR WATER FLOW TRANSMITTER

• Response time of 20 milliseconds typical

• Turndown ratio of 50:1

• Push button interface

• Accuracy of ±2% FSD

• RS232 interface

Process Connections 10-32 UNF 1/8" and 1/4" NPT femaleAccuracy ±2% FSDRepeatability ±2% FSD Response Time 20 msTurndown Ratio 50:1Pressure Drop 0.8 psiPressure 100 psig maxTemperature 50°C maxWetted Materials Stainless Steel, Viton, Silicon Gel,

Nylon & Polyethermide

Power Supply 7 - 30 Vdc, 30mA typicalOutputs 0 - 5 Vdc (4 - 20mA or

0 - 10 Vdc optional)Electrical Connection 2m long 8-core leadDisplay Graphic LCDDigital Output RS-232Dimensions D x W x H

0.01 - 500cm3/min 27 x 61 x 99mm0.02 - 10 L/min 27 x 61 x 104mm

Range Connections Codes(cm3/min)0.01 - 0.5 10-32UNF FFLM00000.02 - 1 10-32UNF FFLM00010.04 - 2 1/8" NPTF FFLM00020.1 - 5 1/8" NPTF FFLM00030.2 - 10 1/8" NPTF FFLM00040.4 - 20 1/8" NPTF FFLM00050.6 - 30 1/8" NPTF FFLM00061 - 50 1/8" NPTF FFLM00074 - 200 1/8" NPTF FFLM000810 - 500 1/8" NPTF FFLM0009

Range Connection Code(L/min)0.02 - 1 1/8" NPTF FFLM00100.04 - 2 1/4" NPTF FFLM00110.06 - 3 1/4" NPTF FFLM00120.1 - 5 1/4" NPTF FFLM00130.2 - 10 1/4" NPTF FFLM0014

The L Series Water Flow Transmitters are designedfor demanding DI Water, or other clean waterapplications. Differential pressure, fluid pressureand temperature are measured in the laminar flowchannel. This information is then used to calculatethe volumetric flow rate of the liquid. All of theabove parameters are dynamically displayed andoutput via the RS232 interface. An analogue outputis also included.

• Blind units are available, also other outputs and flow ranges• Flow controller option available using proportional valve coupled to flowmeter body • Please contact our Technical Sales Team for more details

FLOW

METER

S

www.mess-regeltechnik.at48

Page 47: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Data Sheet DS1730

LAMINAR GAS FLOW TRANSMITTER

Specification

How to Specify

Process Connections 10-32UNF and NPT femaleAccuracy ±0.8% of readingRepeatability ±0.2% FSDAdjustable Resp Time 10 msecTurndown Ratio 100:1Pressure Drop <28mbar up to 505 L/min

<200mbar up to 1000 L/minPressure 145 psig maxTemperature 50°C maxWetted Materials Aluminium, Stainless Steel ,Viton,

Silicon Gel & NylonPower Supply 7 - 30 Vdc, 30mA typ.Output 0 - 5 Vdc (4 - 20mA or

0-10 Vdc optional)

Electrical Connection 2m long 8-core leadDisplay Graphic LCDDimensions D x W x H

0.005 - 50cm3/min= 27 x 61 x 99mm1cm - 20 L/min = 27 x 61 x 106mm 0.5 - 100 L/min = 41 x 102 x 111mm2.5 - 1000 L/min = 41 x 102 x 127mm

20 gas calibrations included:argon,butane,carbon dioxide,carbon monoxide, ethane, helium, hydrogen, iso-butane,krypton, methane, neon, nitric oxide, nitrogen, nitrousoxide, oxygen, propane, sulphur hexafluoride & xenon.

• Blind units are available, also other outputs and flow ranges• Flow controller option available using proportional valve coupled to flowmeter body • Please contact our Technical Sales Team for more details

The M Series Mass Gas Flow and VSeries Volumetric Gas FlowTransmitters measure differentialpressure within the laminar flowchannel to produce an inherentlylinear flow reading. Combinedwith low response time, multipleoutputs, dynamic display and 20user selectable gas calibrations,these units out-perform mostthermal type meters.

M Series incorporates temperatureand absolute pressure measurementsto determine mass flow.

V Series is designed for lowpressure applications venting toatmosphere or with little backpressure.

FLO

WM

ETER

S

+43 1 706 43 000 49

• Response time of 10 milliseconds (adjustable)

• Turndown ratio of 100:1

• Push button interface

• Accuracy of ±0.8% of reading

• 20 standard gas calibrations included

Page 48: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

FLOWMETERS

Specification

Material Stainless SteelRepeatability ±0.1% (typical)Output DP (proportional to the

square of fluid velocity)Temperature -20°C to 225°C insertion

modelRange 0.7 to 250 m3/hr (air @ ATP),

0.1 to 65 m3/hr (water @ 20°C)Tappings 1/4" BSPPipe Connection Threaded NPT MalePressure 30 bar maxPipe Size 1/2" to 2" nominal bore Sch 80

• Flow sensors for liquids or gases

• ±1% of actual flow rate

• Full electron beam welded construction

• Flow averaging

• Integral isolation ball valve

• No power supply required

Insertion Pitot TubeFlo-Bar tubes contain no moving parts.Standard models are manufacturedfrom Stainless Steel, though alternativematerial requirements are readilyaccommodated.

• Flow sensor for liquids or gases

• ±1% of actual flow rate

• Full electron beam welded construction

• Unique profiled sensor with flow averaging

• Integral 3 valve manifold

• Mounting of DP transmitter if required

Please specify with enquiry:• Pipe ID and OD• Preferred connection screwed/flanged• Flowing fluid and conditions• Line pressure and temperature• Output and display preferred

In-line Pitot “Flo-bar”Pipe SectionStainless Steel pipe sections withwelded-in pitot probes, available for1/2" to 2" pipes. Supplied fitted with1/4" ball valves to provide processisolation.

Probe Diameter 25mm standard,100mm-3000mm pipes,13mm for 50-449mm dia pipes60mm for pipes over 3000mm ID

Material Stainless Steel, electron beamwelded construction

Averaging Sensor Typically 6 upstream ports for flow averaging

Installation 7 diameters downstream, 3 diameters upstream (minimum) of a bend or similar obstruction

Connections 1" NPT Female on 54mm centres from integral 3 valve manifold

Flow Repeatability ±0.1% Pressure Max To flange rating 5 bar max for

compression fitting

Please specify with enquiry:• Pipe ID and OD• Preferred connection screwed/flanged• Flowing fluid and conditions• Line pressure and temperature• Output and display preferred

Specification

How to SpecifyHow to Specify

FLOW

METER

S

www.mess-regeltechnik.at50

Data Sheet DS1710

Page 49: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

FLOWMETERS

Accuracy 2% FSD over 95% of flow rangeMaterial Brass bodyPressure 10/16 bar maxTemperature Max temp 40°CWetted Parts Drinking water approved

(75/33/EEC)Installation Horizontal or vertical

Oil MeterFor fuel consumption measurementthe VZO meters are available from1/8" to 1", giving a totalised value offlow on the mechanically drivendials. The meter is unaffected by viscosity change or installationorientation: it can be installed on thepressure or suction side of a pump.

• 1% accuracy over full measurement range

FWM15 FWM20 FWM25Connection dia (bore) mm 15 20 25 Pipe fittings inches 1/2" 3/4" 1" Typical flowrate max m3/h 3 3 7 Typical stall speeds (Min flow) L/hr 10 15 30 Min flowrate (±2% error) L/hr 150 250 350

FWM30 FWM40 FWM50Connection dia (bore) mm 30 40 50Pipe fittings inches 1 1/4" 1 1/2" 2"Typical flowrate max m3/h 10 20 30Typical stall speeds (Min flow) L/hr 40 70 95Min flowrate (±2% error) L/hr 500 1000 1500

Dial registers from/to 0.001/10,000Test pressure Kg/cm2 25

Note: Max flow rate quoted has pressure drop of 10 metres W.G.

Water MeterDesigned for use with clear andtranslucent water at up to 40°C. Thisrange of water meters providemeasurement of water flow by meansof a mechanical totalisation counter.They are stand-alone units whichrequire no mains power.

VZO4/VZO8 metersSize 1/8" & 1/4"Connections BSP Female in meter basePressure 25 bar maxTemperature 60°C maxFormat Compact cubic design

VZO15/20/25 metersSize 1/2", 3/4" & 1"Connections BSP Male in linePressure 16 bar maxTemperature 130°C maxFormat As photo with meter cover

BSP Flow Flow Rec’d Max Start UpConns Max Min Continuous FlowSize L/hr L/hr Flow L/hr L/hr Code1/8" 80 1 50 0.5 FVZO4 1/4" 200 4 135 1.6 FVZO8 1/2" 600 10 400 4 FVZO15 3/4" 1500 30 1000 12 FVZO20 1" 3000 75 2000 30 FVZO25

• Single port for dedicated pipeline flow monitoring

• Direct read out for on-site control

• Optional pulse output

• Tamper proof non-resettable counter

Specification

Specification

Product Codes

Product Codes

• Tamper proof roller counter

• Installation in any orientation

• Optional pulse output

FLO

WM

ETER

S

+43 1 706 43 000 51

Page 50: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

Product Codes

PRE-SET FLOW CONTROLLER

Flow control valves for pure liquid applications which provide a constant pre-set flowrate, independent of line pressure changes. Operation is by means of a rubber orificethat reduces in size as the pressure increases, thus balancing the flow. Installation ispossible on pipework in any plane to fit existing pipework. Available either screwed,for lines up to 2", or as a wafer to fit between flanges. All materials are WRC approvedfor use in drinking water systems.

• Maintains controlled water supply irrespectiveof pressure fluctuation

• Reduces pressure surge & water wastage

• Helps eliminate costly water bills

• Ease of installation & operation

Body Material Brass or Stainless Steel (UPVC option available)

Screwed body BSP FemaleWafer body Fit between BS10 Table E

flanges

Temperature -25°C to 100°CPressure 16 bar maxDifferential Pressure 6.5 bar maxRubber Controller NitrileAccuracy ±10%

Threaded:-Pipe Set Flow Brass Body SS BodySize (L/min)1/2" 0.4 F59290004 FVFC00041/2" 0.7 F59290007 FVFC00051/2" 1.0 F59290010 FVFC00061/2" 1.5 F59290015 FVFC00071/2" 2.0 F59290020 FVFC00081/2" 3.5 F59290035 FVFC00091/2" 5.0 F59290050 FVFC00101/2" 7.0 F59290070 FVFC00111/2" 10.0 F59290100 FVFC00121/2" 15.0 F59290150 FVFC00131/2" 23.0 F59290230 FVFC00143/4" 32.0 F59290320 FVFC00153/4" 41.0 F59290410 FVFC00163/4" 54.0 F59290540 FVFC0017

1" 73.0 F59290730 FVFC00181" 91.0 F59290910 FVFC00191" 114 F59291140 FVFC002011⁄2" 160 FVFC0000 FVFC002111⁄2" 200 FVFC0001 FVFC00222" 200 FVFC0002 FVFC00232" 230 FVFC0003 FVFC0024

Water:-Pipe Set Flow Brass SS Size (L/min)2" 342 FWFC20 FVFC002521⁄2" 456 FWFC25 FVFC00263" 675 FWFC30 FVFC00274" 1080 FWFC40 FVFC00285" 1620 FWFC50 FVFC00296" 2565 FWFC60 FVFC0030

PVC Versions available on request

FLOW

METER

S

www.mess-regeltechnik.at52

Page 51: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Data Sheets MN DS1511 • FV DS1521

MN & FV AUTOMATIC FLOW CONTROLLERS

Specification - MN

Body Material Polyester coated Brass or 316 Stainless Steel

Diaphragm and Seals Brass body - NitrileSS body - PTFE

Temperature Nitrile 80°C, PTFE 100°CPressure Brass/Nitrile 20 bar max

SS/PTFE 28 bar maxProcess Connection 1/4" BSPP femaleRepeatability ±1%Accuracy Liquids: ±2%

Gases: ±3%

Flow RangesAir@ATP (L/min) Water@20°C (L/min) Type A Code Type B CodeBrass0.005 - 5 0.002 - 0.2 FMNAB11 FMNBB110.1 - 30 0.05 - 1.5 FMNAB21 FMNBB218 - 100 0.25 - 3.5 FMNAB31Stainless Steel0.005 - 5 0.002 - 0.2 FMNAS12 FMNBB110.1 - 30 0.05 - 1.5 FMNAS22 FMNBB218 - 100 0.25 - 3.5 FMNAS32Spare KitsMN Nitrile Diaphragms & Seals FMNAKN FMNBKNMN PTFE Diaphragms & Seals FMNAKP FMNBKP

Body Material Epoxy coated Brass or 316 Stainless Steel

Diaphragm and Seals Brass body - NitrileSS body - PTFE

Temperature Nitrile 80°C, PTFE 100°CPressure 16 bar max or flange

rating if lowerProcess Connection 1/2" - 3/4" BSPP Female

1" - 4" flanged to BS, DIN or ANSI

Repeatability ±1%Accuracy Liquids: ±2% Gases: ±3%

Flow RangesAir@ATP (L/min) Water@20°C (L/min) Type A Code Type B CodeBrass13 - 133 0.3 - 4.5 FFVAB11 FFVBB1120 - 200 0.6 - 6.5 FFVAB13 FFVBB1240 - 400 1.3 - 13 FFVAB13 FFVBB13Stainless Steel13 - 133 0.3 - 4.5 FFVAS21 FFVBS2120 - 200 0.6 - 6.5 FFVAS22 FFVBS2240 - 400 1.3 - 13 FFVAS23 FFVBS23Spare KitsMN Nitrile Diaphragms & Seals FFVAK0.5N FFVBK0.5NMN PTFE Diaphragms & Seals FFVAK0.5P FFVBK0.5P

Specification - FV

Product Codes Product Codes

Flostats maintain liquid or gas flow at a pre-selected rate regardless of line pressurefluctuations. Using an internal orifice to measure flow, the differential pressure pro-duced drives an internal control valve. Only a small pressure drop in the line isrequired for satisfactory operation.

Specify option ‘A’ for all liquid applications and gas applications where pressurefluctuations occur downstream, or option ‘B’ where supply pressures only aresubject to fluctuation.

• Entirely automatic- no external power needed

• Suitable for use on hazardous fluids - intrinsically safe

• High response speed for close flow control

• 10:1 control range

• High long term reliability

• 1/4” to 4” sizes as standard

FLO

WM

ETER

S

+43 1 706 43 000 53

Page 52: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Data Sheet DS1531

AUTOMATIC FLOW CONTROLLERS

Specification

How to Specify

Body Material Epoxy coated Mild Steel or Stainless Steel Valve Trim Stainless SteelDiaphragm NitrileTemperature 80°C maxPressure 20 bar max or flange rating if lowerMaximum Pressure Drop 5 to 10.5 bar depending on flostat sizeProcess Connection 2" to 6" flanged to BS, DIN or ANSIReproducibility ±2%Control Accuracy ±5%Adjustment Plain or with scale plate, or factory pre-setActuation Manual or pneumatic

Contact our Technical Sales Team with Featuresthe following information:

• Pipe size • Fully automatic

• Fluid type, SG and viscosity if unusual • 10:1 control range

• Body and diaphragm materials • No power required

• Flow range • Simple and reliable

• Flange type • Fast response

• Fluid temperature and pressure • High accuracy

Platon B and LB Flostats

Automatic Flow Controller

• Ideally suited to welding, brewing and control applications

• Entirely automatic - no external power needed

• High response speed for close flow control

• High long term reliability

• Wide rangeability - adjust to site requirements

• Designs in anodised aluminium and brass typically

• Wide range of flow control from 10 to 5000 L/min

Ideal for maintaining gas flow at a pre-selected rate, when down stream pressure fluctuates. Control is based on flow measurement using an internal orifice.This meansthat the controller requires a small pressure drop in the line. This is fixed and quotedin subsequent table. The design is suitable for gas when upstream pressure is reasonablyconstant and downstream is variable, eg filling a buffer tank.

* See page 55 for specification details

FLOW

METER

S

www.mess-regeltechnik.at54

Page 53: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

AUTOMATIC FLOW CONTROLLERS

Flow Range 0.5 to 10 0.5 to 25 25 to 300 75 to 1000 250 to 5000Air@ATP (L/min)For 14 Bar SupplyRepeatability ±1% ±1% ±1% ±1% ±1%Accuracy ±3% ±3% ±3% ±3% ±3%Body Material Brass Aluminium Alloy Aluminium Alloy Aluminium Alloy Aluminium AlloyDiaphragm & Seals Nitrile Nitrile Nitrile Nitrile NitrileInternal Parts Brass, St Steel Brass, St Steel Brass, St Steel Brass, St Steel Brass, St Steel

Acetal Resin Acetal Resin Acetal Resin Acetal Resin Acetal ResinProcess Connections 1/8" BSPP 1/8" BSPP 1/4" BSPP 1/2" BSPP 1" BSPPTemp Range -10ºC to +50ºC -10ºC to +50ºC -10ºC to +50ºC -10ºC to +50ºC -10ºC to +50ºCPressure Bar G Max 14 14 14 14 14

Design Details

Product Codes

Dimensions mm 50 x 30 x 30 38 Diameter 60 Diameter 80 Diameter 120 DiameterWeight kg 0.7 0.45 0.75 1.0 2.0

• Various inlet/outlet connection available for 25 L/min model

FFCV 5000

FFCV 0010

FFCV 0300

FFCV 0025

FFCV 1000

FFCV 0025

Flow Control Valves 10, 25, 300, 1000 and 5000 (L/min)The unique valve design maintains accurate gas flows when supply pressure remainsconstant but where downstream pressure can fluctuate.

Specification

Codes FFCV0010 FFCV0025 FFCV0300 FFCV1000 FFCV5000

FLO

WM

ETER

S

+43 1 706 43 000 55

Page 54: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

INDICATORS

Connections Screwed: BSPP FemaleFlanged: ANSI 150

Wetted Materials Stainless Steel or Gunmetal,Toughened soda lime glass,PTFE, Klingersil C4400

Pressure 16 bar maxTemperature Stainless Steel: 250°C max

Gunmetal: 100°C maxPaddle Material Stainless Steel: Glass filled PTFE

Gunmetal: POM (Hostaform)

• High visibility spinner

• Ideal for flow indication in full pipes

• Mounted in any pipe position

• High quality, robust design

• High pressure option up to 60 bar

BallA mechanical flow indicator for gasesor liquids where the ball is lifted fromthe valve seat by the fluid flow. Thebouncing ball under the glass domegives an immediate moving indicationof flow. Horizontal pipe lines only.

• Clear indication that flow is present

• High temperature / pressure capability

• Excellent chemical compatability

• Suitable for use on condensate, liquids and gases

• Unrivalled flow and pressure dropperformance

Size Screwed Flow (L/min)* SS Gunmetal1/2" 3.5 to 25 FSI15S FSI15B3/4" 4 to 40 FSI20S FSI25B1" 7 to 60 FSI25S FSI20B11⁄2" 17 to 160 FSI40SFlanged2" 25 to 240 FFSI00043" 60 to 600 FFSI00054" 100 to 950 FFSI00066" 250 to 2200 FFSI0007

* Operating range (Gunmetal models work down to 75% of min. flow stated above)

Paddle WheelThis model can be mounted in anyorientation and operates over a wideflow range. Suitable for clear orcloudy liquids.

Body 316 Stainless SteelSight Ball PTFEO-Ring Seals VitonGasket Klingersil C4400Dome Borosilicate GlassPressure 16 bar maxTemperature 200°C max

Air flow rates are typically 15 to 30 times thosespecified for water, dependent upon line pressure

Connections Min WaterBSP Flow (L/min) Code1/4" 0.3 FBFI8 3/8" 0.3 FBFI10 1/2" 0.3 FBFI15 3/4" 2.5 FBFI20 1" 4.0 FBFI25 1 1⁄2" 11.0 FBFI40

Specification

Specification

Product Codes

Product Codes

FLOW

METER

S

www.mess-regeltechnik.at56

Page 55: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification Specification

INDICATORS

Connections Screwed: BSPP FemaleFlanged: ANSI 150

Wetted Materials Stainless Steel or Gunmetal,Toughened soda lime glass,PTFE, Klingersil C4400

Pressure 16 bar maxTemperature Stainless Steel: 250°C max

Gunmetal: 200 °C max

• Stainless Steel flap and scaleplate

• Provides a visual indication of flow conditions within piping

• Ideal for flow monitoring in full pipes

• High quality, robust design

PlainSuitable for viewing flow conditions inapplications with intermittent flow,entrained air and partially filled pipes.A special version for use with steamand condensate uses Borosilicate Glassto ensure good long-term visibility.

• Allows visual inspection of pipe contents

• Integral drip spout, ideal for leak detection

• Suitable for mounting in any pipe position

• Steam and condensation option available

• High quality, robust design

Screw Size Flow (L/min)* SS Gunmetal 1/2" 20 FFI15S FFI15B3/4" 20 FFI20S FFI20B1" 30 FFI25S FFI25B11⁄2" 55 FFI40S

Flange Size2" 70 FFSI00003" 230 FFSI00014" 400 FFSI00026" - FFSI0003

* Approximate FSD for water in horizontal pipes (not specified for 6" version)

FlapThis style is particularly suited to fullbore flows, giving an indication offlow rate against a unit scale. Suitablefor horizontal or vertically upwardflow.

Connections Screwed: BSPP FemaleFlanged: ANSI 150

Wetted Materials Stainless Steel or Gunmetal,Toughened soda lime glass,PTFE, Klingersil C4400

Pressure 16 bar maxTemperature Stainless Steel: 250°C max

Gunmetal: 200°C max

Screw Size SS Gunmetal Flange Size SS 1/2" FPI15S FFSI0012 2” FFSI00083/4" FPI20S FFSI0013 3” FFSI00091" FPI25S FFSI0014 4” FFSI001011⁄2" FPI40S n/a 6” FFSI0011

With Borosilicate Glass (max pressure 8 bar) Screw Size Gunmetal1/2" FPI15B3/4" FPI20B1" FPI25B

Product Codes Product Codes

FLO

WM

ETER

S

+43 1 706 43 000 57

Page 56: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

Product Codes

PRE-SET FLOW SWITCH

Liquid low flow switch for alarm duty on 1/2" or 3/4" pipe. Install with flow verticallyupwards. Contacts made for high flow, i.e. normal conditions.

Pipe Size Flow Range Code Pipe Size Flow Range Code(L/min) (L/min)

Brass Models SS Models1/2" BSPP 0.3 FLFB14L 1/2" BSPP 0.3 FLFS14L1/2" BSPP 0.5 FLFB11L 1/2" BSPP 0.5 FLFS11L1/2" BSPP 1.0 FLFB12L 1/2" BSPP 1.0 FLFS12L1/2" BSPP 2.5 FLFB13L 1/2" BSPP 2.5 FLFS13L 1/2" BSPP 3.5 FLFB15L 1/2" BSPP 3.5 FLFS15L 3/4" BSPP 1.0 FLFB22L3/4" BSPP 2.5 FLFB23L 3/4" BSPP 5.0 FLFB24L3/4" BSPP 10 FLFB25L

• Low cost flow alarm

• Simple rugged construction

• Brass, BSPP connections

• Selectable alarm trip level (factory set)

• Stainless Steel and other special OEM versions available

Body FLFB Brass CZ121FLFS Stainless Steel

Connections 1/2" or 3/4" BSP FemaleFlow Sensor FLFB - Brass with encapsulated magnet

FLFS - Stainless Steel with encapsulated magnetOutput SPST reed switch - open circuit for low flowWires 300mm longRating Max 300V, 500mA, 10WPressure 70 bar maxTemperature 100°C maxLength 1/2" BSP model: 90mm

3/4" BSP model: 100mmSW

ITCH

ES

www.mess-regeltechnik.at58

Data Sheet DS1431

Page 57: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

ADJUSTABLE (LIQUID) FLOW SWITCH

Specification

Product Codes

Pipe Connections 1/4" - 1" BSPFlow Range 0.4 - 40 L/minBody Ml Models - Brass; Kl Models - Stainless SteelSeals Ml Models - Buna N; Kl Models - VitonPressure 200 bar maxTemperature 120°C maxCable 2.5m long IP65 terminationOutput SPC0 250Vac VA 1.5 AmpsPressure Drop 0.5 bar at max flowLength MR8-20 109mm

MR25 135mm

Pipe Connections Flow Switch Adjustment Max Flow CodeBSP (L/min) (L/min)

1/4" Brass 0.4 - 4 15 FMR8MI 3/8" Brass 0.4 - 4 20 FMR10MI1/2" Brass 1 - 10 40 FMR15MI 3/4" Brass 5 - 20 60 FMR20MI 1” Brass 10 - 40 80 FMR25MI

1/4" SS 0.4 - 4 15 FMR8KI3/8" SS 0.4 - 4 20 FMR10KI1/2" SS 1 - 10 40 FMR15KI 3/4" SS 5 - 20 60 FMR20KI1” SS 10 - 40 80 FMR25KI

Using a spring loaded variable orifice flow meter technique, the sensor can beinstalled at any angle and can operate at high pressures and temperatures. Themoving element trips an external reed sensor, which itself can be adjusted along aflow scale.

• Compact

• Good repeatability

• Dirt resistant

• High switch capability

• Hermetic separation of mechanical and electrical components SW

ITC

HES

+43 1 706 43 000 59

Page 58: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

Product Codes

PADDLE (LIQUID) FLOW SWITCH

• Good repeatability

• Low pressure loss

• Dirt resistant

• Hermetic separation of electrical and hydraulic components

• Stress free fixing of switch unit by plastic cap

Pipe Sizes 1/4" - 2"Hysteresis 0.7 L/min - depending on switch valueConnection BSP FemaleLimits 25 bar max, 110°C maxMaterial Brass or 316 Stainless StreelCable Length 1.5mOutput Reed contact, 1 Amp at 250V max. Selectable NO/NC SPSTProtection IP65

Connections Flow Range Max Flow Brass Code SS Code BSP F (L/min) (L/min)

1/4" 2.5 - 3 5 F59300105 F594001053/8" 3 - 3.5 10 F59300106 F594001061/2" 4.5 - 5 20 F59300107 F594001073/4" 5 - 6 40 F59300108 F594001081 9.5 - 11.5 60 F59300116 F5940011611⁄4" 13 - 16 80 F59300117 F5940011711⁄2" 30 - 35 100 F59300118 F594001182" 42 - 53 150 F59300119 F59400119

The body of the flowswitch is a standard pipetee, BSP threaded, which contains a paddle typevane. Flow pushes the vane against magneticforces: when flow exceeds a critical value themagnet actuates a reed switch. By coarseadjustment of the reed switch position, theoutput is changed between N/O & N/Ccontacts: fine adjustment changes the flowsensitivity and switch rate.

SWITC

HES

www.mess-regeltechnik.at60

Page 59: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

EXPLOSION PROOF FLOW SWITCH

Specification

Product Codes

The Flotect is a paddle operated flowswitch for 1/2" to 2" pipelines. Magneticcoupling between the spring loadedvane and the microswitch gives a totallyglandless construction, suitable forgases or liquid up to 2000psi. Modelsare available with Stainless Steel or Brassprocess parts.

• Leak proof lower body machined from bar stock

• Weatherproof

• Low flow model offers field adjustable set point

• Easy installation, simply insert the tee in the pipeline and complete electrical connections

• ATEX approved

Body Stainless Steel or BrassVane Stainless Steel Mounting Any planePressure Brass 17 bar

Stainless Steel 138 barTemperature 105°C maxElectrical Contact SPDT switchRating 5 Amps at 125/250VacApproval ATEX approval

Connections Low Flow Trip Point (approx) Brass Code SS CodeNPT F Gas Flow (m3/hr) Liquid Flow (L/min) (Tee Piece) (Tee Piece)

1/2" 9 4 FFSV6S1BC FFSV6S1SC 3/4" 14 5 FFSV6S2BC FFSV6S2SC 1" 20 7 FFSV6S3BC FFSV6S3SC 11⁄4" 30 11 FFSV6S4BC FFSV6S4SC 11⁄2" 50 19 FFSV6S5BC 2" 60 30 FFSV6S6BC

SWIT

CH

ES

+43 1 706 43 000 61

Page 60: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification Specification

How to Specify

How to Specify

PADDLE FLOW SWITCHES

Pipe Sizes 11⁄2" - 8"Paddle Stainless SteelSwitch SPCO, 8A 250VacIP Rating IP65Model VKB Brass bodyLimits 11 bar, 120°C maxModel VKS Stainless Steel bodyLimits 30 bar, 120°C max

Site Adjustment (m3/hr)Pipe Minimum MaximiumBore Off-On Off-On11⁄2" 1.1 1.7 3.7 4.02" 2.2 3.1 5.7 6.13" 4.3 6.2 10.7 11.44" 11 15 27 295" 23 28 53 566" 36 43 81 858" 73 85 166 173

CodeFVKBFVKS

Adjustable Liquid Paddle SwitchFor liquid flow alarms at site adjustableflow rates, these paddle flow switchesare simply mounted in a horizontalflow line, through a 1" BSPconnection. The vane is selected orcut to suit the pipe size.

Approximate Actuation/De-actuationPipe Water L/min (20°C) Air m3/hr (ATP)Size Act. De-act. Act. De-act.1" 40.9 34.6 66.3 55.411⁄4" 37.2 31.4 63.7 54.711⁄2" 32.4 25.7 56.7 45.42" 41.2 33.4 73.1 62.53" 48.8 33.5 89.6 664" 79.7 52.5 148.9 108.16" 170.2 124.7 286.5 233.4

CodeFV8FV8-IP67 (weatherproof version)

Electrical Connection 3 x 460mm 18AWG wire

Temperature Limit 100°C maxOperating Pressure 10 barPipe Connection 1" NPTSwitch SPDT, 5 Amps at 125/250Vac Body and Vane Polyphenylene Sulphide (PPS),

Ceramic 8 magnetStainless Steel pin and spring

Installation Install with index arrow indirection of flow

Adjustable Plastic Paddle(Liquid/Gas)Made from chemical resistant anddurable polyphenylene sulphide, thisplastic paddle flow switch is suitable

for either liquid or air. Whenflow stops the Stainless Steelvane spring moves the vaneand activates a switch tostop/start a pump, alarm oropen/close a valve. Theplastic vane is trimmable toallow for installation on pipesfrom 1" to 6".

• IP67 connection head (opt)

• Leak proof body

• Field trimmable vane

• Excellent chemical resistance

• Suitable for 40mm to 200mm pipe

• Good repeatability

• Low pressure loss

SWITC

HES

www.mess-regeltechnik.at62

Data Sheet DS1401

Page 61: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Data Sheet DS1402

SWITCHES

Specification

Specification

How to Specify

Product Codes

Elect.Connection 2 x 460mm 22 AWG wireTemp Limit 93°C MaximumOperating Pressure Brass body 69 bar SS body 138 bar Pipe Connection 1/2" NPTSwitch SPST reed switchElectrical Rating 1.5A,24Vdc resistive,0.5A,125VacBody Brass or Stainless Steel,Ceramic 8

magnetVane Stainless SteelInstallation Install with index arrow in

direction of flow

Air/Liquid Mini Flow Switch (V11)The V11 flow switch takes the verypopular V10 design and adds rugged,integral electrical wiring. the one-piece PBT switch housing snaps ontothe body and the wiring is epoxysealed making the switch weather-proof.

• Leak proof body

• Low cost

• Field selectable switch operation NO/NC

• Field trimmable vane

Approximate Actuation/De-actuation (for V10 and V11)Water L/min (20°C)Pipe NO NCSize Act. De-act. Act. De-act.1/2" 9.8 8.7 9.8 9.5 3/4" 11.7 10.2 11.7 10.6 1" 18.2 17.0 18.2 16.7 11⁄4" 23.5 21.2 23.1 21.2 11⁄2" 31.0 29.1 31.0 29.1 2" 36.0 34.4 36.0 34.1

Air Nm3/Hr (ATP)Pipe NO NCSize Act. De-act. Act. De-act.1/2" 17.5 15.0 17.3 15.63/4" 22.1 19.7 21.9 19.71 1⁄4" 32.6 29.9 32.1 29.911⁄4" 42.1 37.7 41.6 38.211⁄2" 56.8 53.0 56.1 52.02" 85.3 82.2 85.3 81.1

Body Type CodeBrass FV10BStainless Steel FV10S

Air/Liquid Mini Flow Switch (V10)These simple paddle flow switchesare used to monitor the presence orabsence of air or liquid flow. Theswitch can be adjusted by the userfrom Normally Open (NO) toNormally Closed (NC) easily withoutinterrupting process flow.

Electrical Connection 1 x 1.8m 22 AWG Temp Limit 121°C maxOperating Pressure Brass body 69 bar

SS body 138 bar Pipe Connection 1/2" NPTSwitch SPST reed switchElectrical Rating 1.5A, 24Vdc resistive, 0.5A,

125VacBody Brass or Stainless Steel

Ceramic 8 magnetVane Stainless SteelInstallation Install with index arrow in

direction of flow

Type CodeBrass Normally Open FV11B-NOBrass Normally Closed FV11B-NCStainless Steel Normally Open FV11S-NOStainless Steel Normally Closed FV11S-NC

• Weatherproof head

• Leak proof body

• Low cost

• Snap-on electrical housing allowing service without process shutdown

•Trimmable vane for 1/2" to 2" pipe sizes

SWIT

CH

ES

+43 1 706 43 000 63

Page 62: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

Product Codes

EXPLOSION PROOF ADJUSTABLE FLOW SWITCH

For pipelines from 1 1/2" to 20", this paddle operated flowswitch uses magnetic coupling to transmit the vanemovement across a solid metal diaphragm to the electricalswitch output. Suitable for general purpose use. They aresupplied with a multi-layer vane suitable for all pipe sizes, onliquids or gases. Normal mounting is vertical, via a 11/2" NPTThreadolet welded to the horizontal pipeline.

• Leak proof body machined from bar stock

• Installs directly and easily into pipeline with a threadolet, tee or flange

• Vertical options available

• High pressure rating of 1000 psig (69 bar) with the brass body and 2000 psig (138 bar) with 316 Stainless Steel body

• Rugged construction

• Multi-layer universal vane

• ATEX approved

Body Stainless Steel or Brass, 1 1/2" NPT fittingVane 316 Stainless Steel Mounting Vertical ±5° to horizontal pipePressure Brass 69 bar

Stainless Steel 138 barTemperature 135°C maxElectrical Contact SPDT reed switchRating 10 Amps at 125/250VacApproval ATEX approval

Body General Explosion Type Purpose ProofBrass FFSV4B FFSV4BC Stainless Steel FFSV4S FFSV4SC

Alarm and Reset Flow RatePipe Diameter Water Flow Air Flow

(m3/hr) (Nm3/hr)11⁄2" 0.7 - 1.6 29 - 722" 0.9 - 3.4 22 - 1083" 1.6 - 10 72 - 360

Pipe Diameter Water Flow Air Flowm3/hr Nm3/hr

4" 2.7 - 22 72 - 6846" 6.8 - 48 180 - 16208" 15 - 85 432 - 262810" 23 - 136 900 - 396012" 32 - 204 1350 - 576014" 45 - 273 2100 - 792016" 57 - 318 2700 - 1080018" 74 - 454 4000 - 1368020" 91 - 545 4700 - 16920

SWITC

HES

www.mess-regeltechnik.at64

Page 63: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

LEVEL SWITCHES

Material Glass filled PolypropyleneGrommet Silicone rubber (LS1 only)Limits 110°C max, 5 bar maxLiquid SG 0.70 minReed Contacts SPST: NO/NC choice by float

reversal. Resistive loads onlyContact Rating 1 Amps 15 watts 250Vac/100VdcLead Length 0.5m 2 coresDiameter Float 22mmMounting Hole 23mm if installed from outside,

16.5mm if installed from insideContainer Wall 4mm maxFittings 1/4" NPT M (RS1, VS1)

Horizontal Stainless SteelFor liquid level control using a sidemounted Stainless Steel float switch. Amagnet in the float activates a reedswitch.

Description CodeHorizontal unit FLS1Vertical unit FVS1Right angle unit FRS1

Other model options available on request

Plastic FloatFloat operated liquid level alarmswitches in glass filled polypropylene.LS1 units can be installed from outsidethe tank - a special sealing grommetgives a water tight seal for up to 70 psi.

Material Stainless SteelSwitch Rating SPST 5A 240Vac 50VATemperature -40°C to +120°CMODEL SRS: Right angle stem fittingPressure 10 bar maxLiquid SG 0.75 minMounting 1/8" BSPP from inside tankLeads 30cm, 2 coresFloat Ø 28mmSwitch Level 50mm above/below holeMODEL SLS: Horizontal cylindrical floatPressure 5 bar maxLiquid SG 0.7 minFloat Ø 17mmInsertion Length 92mmMounting 1/2" BSPT from outside the tankConnections 30cm flying lead or DIN IP65 plug

Description CodeRight angle stem FSRS22Horizontal Cylindrical Float1/2" BSPT, flying leads FSLS121/2" BSPT, DIN IP65 plug FSLS12P

Specification

Product CodesProduct Codes

FSLSFRS1

FVS1

• All Stainless Steel

• High temperature up to 120°C

• Compact design

• Optional DIN plug for SLS version

• N/O or N/C

FSRS

• Suitable for use on many fluids,acids,oils

• Water Council approved for drinking water applications

• Reversible float gives N/C or N/O reed switch action

• Universal mounting kit allows simple fitting from outside tanks

• Compact units for use in small tanks

SWIT

CH

ES

FLS1

+43 1 706 43 000 65

Specification

Page 64: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

LEVEL SWITCHES

Specification

Product CodesProduct Codes

Specification

Materials 316 Stainless SteelSwitch Rating SPST 5A 240Vac 50VALeads 30cm 2 coreMODELS SVSPressure 10 bar maxTemperature -40°C to +120°CLiquid SG 0.75 minMounting 1/8" BSPP from inside tankFloat Ø 28mmMODEL RFS: High temperature versionPressure 10 bar maxTemperature 200°C maxLiquid SG 0.53 minMounting 3/8" BSPPFloat Ø 50mmInsertion Length 75mm

• Pump control

• Machinery protection by signalling lack of coolant or lubricant

• Ideal for small tanks where space is limited

• Model RFS: foruse in hot oiltanks, fat fryers

PeardropThe float contains a tilt switch and issuspended into the tank or sumpfrom above on the cable. Above thefloat a weight holds the cable vertical;when the liquid causes the float to riseit switches an SPDT microswitch totrigger an alarm or pump.

• Adjustable counter weight position to select the level differential

• Blow moulded moplen outer casing, chemical resistant and shock-proof

• Lead spheric actuator of the electrical switch to avoid oxidation and blocks

Description CodeVertical mounting FSVS22Vertical mounting, high temperature FRFS62

Vertical Stainless SteelFor liquid level control and tank levelalarm using all Stainless Steel wettedparts. A magnet in the float activates areed switch to give an electrical con-tact closure.

• Storage tank high level alarms

Float Polypropylene homopolymerCable Thick PEC double insulatedCable Length 5m, 10m or 25mRating IP67 (to 50 metres)Output 1 Amps 15 watts 250Vac/100VdcTemperature 60°C maxBallast Weight 200gm Polyurethane (Note: this

should be positioned typically0.5m from float)

NB It is recommended that this float should be used with a relay module (p69) to switch AC power circuits.

Float Switch with: Model5m cable FEC510m cable FEC1025m cable FEC25

SWITC

HES

www.mess-regeltechnik.at66

Page 65: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

CAPACITANCE LEVEL TRANSMITTER

Specification

Product Codes

• Continuous monitoring

• Robust and reliable

• Plastic or insulated tank

• Metal or reinforced concrete tank

• Cost effective

• Simple to install

• No dead band

• Rigid probes up to 3m long

Insertion Length Rigid up to 3mProcess Connection 1" BSP Process Temperature 100ºC maxAmbient Temperature -20ºC to 60ºCProcess Pressure 300psi @ 20ºCTermination Head Polypropylene as standardElectrical Connection Screw TerminalsConnection Cable Screened Electrode Material Type 316 SS (other materials to special order)Electrode Insulation Polypropylene (other materials to special order)

FCP3/4-20/1mFCP4/4-20/1m

Other probe lengths available on request

FCP4Probe with concentric metallic tube electrodefor non-conducting liquids such as oils etcgenerally with low dielectric constant.Standard material is stainless steel.

FCP3Probe with concentric metallic tube with inner tubeinsulated, for use with conductingliquids such as aqueous solutions. Standardmaterial stainless steel, sheathed withpolypropylene. Other insulation options areavailable.

LEV

EL

+43 1 706 43 000 67

Page 66: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

How to Specify

Construction Materials Casing: Polypropylene (glass filled), Transducer housing: UPVCMounting Bracket Swing type bracket Measuring Range 0.5 to 8mOutput 4-20mA (into 250ohms @ 240Vdc or 850 ohms @ 38Vdc)Loop Voltage 20-38Vdc (reverse polarity protected)Power Required 0.5 watts @ 24VResolution 1mmAccuracy 0.25% of measuring range (electronic)Display 4 digitsMinimum Span 100mmLost Echo User programmable 4, 20, 21mA or last valid readingTemperature Compensation Built it digital sensorOperating Temperature -10°C to +60°CWeatherproof IP68 (immersion in water at 2m for 24 hrs)Gland Thread M20Cable 2 core screened cable or twisted pairUniversal Flange Suitable for ANSI 3" 150lb, DN 80 PN16, BS10 table D 3", type 81 bracketUltrasonic Core Angle: 12°Max Static Operating Pressure -0.25 to 2 bar @ 20°C

Options

• If 4 control relays, digital indication and a power supply are required use Flexilevel 2 as an add on unit

• If only 2 relays and a power supply are required use Type 800 Dual Trip Amp or the PS2 power supply with cable monitoring and lost echo

Code: USLT1Dual Trip Amp PS2 power supply

Please contact our Technical Sales Team to discuss your application

ULTRASONIC LEVEL TRANSMITTER

• Simple setting up procedure,save commissioning time

• Low power consumption gives economical operation

• Self-diagnosis facility and automatic re-calibration

• Polypropylene casing for increased chemical resistance

• Weatherproof to IP68 (2m for 24 hours)

• The integral moulded flange accepts ANSI, DIN, BS, sizes

The Ultrasonic Level Transmitter provides accurate, reliable level measurement forliquids and slurries. It is a loop powered, ultrasonic transmitter which operates froma 20 - 38Vdc supply, thus enabling the 4-20mA signal produced to be transmittedover relatively long distances.

LEVEL

www.mess-regeltechnik.at68

Page 67: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

Specification

LEVEL CONTROL

Electrodes 1 metre long Ø 3.2mmStainless Steel, epoxycoated-4 off supplied

Holder Moulded PolypropyleneMounting Thread 3/4" BSP (locknut provided)Conduit Thread M20Temperature -20°C to +60°C

• Tank level control for any conducting liquid

• High level alarm

• Low level alarm

• Dual point pump control

Pump Control or Level AlarmModule

• Use with Electrodes or Level Switches on pages 65 and 66

• Connections for two sensors for pump control

Description CodeElectrode holder and FE144 off 1m long probes

Other options available on request

Level Control Electrodes

Supply Voltage 110/230VacTemperature -15°C to +45°CEnclosure 48 x 48, 96mm deepMounting Front panel or supported by

baseConnections Via 11 pin base plug in unitOutput Relay 240Vac 5 AmpAlarm Function DPDT for level alarm, or SPDT

for pump controlSensing Circuit Probe or float monitoring via

14Vac sensing circuit. Outputrelay de-energises whenproduct is detected.

Front Panel LED Indicates when relay energisedTime Delay 0 - 15 seconds adjustable to

prevent frequent alarms andrelay chatter from liquidturbulence

Description CodeModule with variable time delay option FRLM48TAccessory11pin mounting base FRLM11B

For site adjustable liquid level controlpoints on aqueous liquids, this fourelectrode probe is mounted on thetank top. Electrodes are cut to lengthon site to define a) high or low levelalarm, b) pump “on” level, c) pump “off”level, or similar functions, with the lastelectrode left as the common or earth.Electronic output is then made usingrelay module RLM48T, with simpleelectrical connections to the terminalhead.

Panel mounted interface betweensimple liquid level sensors andmains high current devices such aspumps, klaxons or lamps. Sensorscan be any float switch or multipointelectrode systems, which are drivenwith a low voltage, safe sensingcurrent.

Product CodesProduct Codes

LEV

EL

+43 1 706 43 000 69

Page 68: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Data Sheet DS1810

Standard Pneumatic ActuatorSignal Input Direct acting 3 -15 psiTemperature -20°C to 50°C AmbientVariants Air-to-Open or Air-to-CloseHousing Die-cast aluminiumDiaphragm/Seals Nitrile

Pneumatic PositionerType Moore Positioner built onto

standard air motorAir supply Max 100 psi, min 5 psi above

required valve actuationpressure

Signal Input 3-15 psiTemperature -20 to 50°C AmbientVariants Air-to-open or air-to-close

Specification

How to Specify

M-ValveBody Material 316 Stainless Steel (Options - Carbon Steel, Monel, Hastelloy, PVC)Packing Braided PTFE (Options - Solid PTFE, Chevron, Bellow Seals)Fluid Temperature -75 to 190°C (Option - Cryogenic to 400°C)Pressure 150 bar max (subject to valve packing)Process Connections 1/4" or 1/2" NPT standard

PROPORTIONAL CONTROL VALVES

Platon M - ValvesFor use on gas, liquids or steam, the M-Valve is an air operated proportionalcontrol valve for 1⁄4" or 1⁄2" lines. Theinterchangeable plug and seat trims areavailable with CV values from 3.0 down to0.00007, with a control range of up to 40:1.The standard actuator is available withair-to-open or air-to-close action, using3-15 psi. For high line pressures or for verylow flow control a pneumatic positioneris recommended.

• Pilot plant control

• Dosing, blending or flavour flow control

• Cryogenic liquid control for cooling

• Hazardous area applications

• Bellows sealed units for dangerous gases, nuclear applications.

To specify and size the M Valve trim required, please specify:

• Line size

• Connections required

• Valve materials

• Upstream and downstream pressure

• Air-to-Open or Air-to-Close

• Linear or equal % trim

• Fluid type, SG, viscosity, density

• Temperature

• Valve pressure drop

• Max flow rate and flow range required

VA

LVES

www.mess-regeltechnik.at70

Page 69: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

FCV FINE CONTROL VALVES

Specification

Product Codes

A selection of fine control needle valves suitablefor gradual opening and closing of gas or liquidflows. Suitable for use with all Platon Glass Tube VAflowmeters, the standard FCV is rated at up to 25bar line pressure. As with all control valves the FCVis not designed for total leak free shut off.

Valve Body Brass or Stainless SteelValve Needle 316 Stainless SteelSeals Nitrile with Brass

Viton with Stainless SteelConnections 1/4" BSPP Female threadMax Operating Pressure 25 bar, higher to special orderMax Operating Temp 80°C

• 1⁄4" BSPP Connection fits directly into pipework

• Fits in any orientation

• Choice of low, medium or high flow control

• Ideal for use with NGXI, LGXI and GU flowmeters

• Brass or Stainless Steel options

Body Material Flow Rate at ATP & Order Code Adaptor Type Order Code0.25 bar Air

Brass 0 - 10 L/min FFCVBL LGXI/NGXI Brass F5842112Brass 0 - 45 L/min FFCVBM LGXI/NGXI Stainless Steel F5842114Brass 0 - 100 L/min FFCVBH GU Brass F5842122Stainless Steel 0 - 10 L/min FFCVSL GU Stainless Steel F5842124Stainless Steel 0 - 45 L/min FFCVSMStainless Steel 0 - 100 L/min FFCVSH

* CVA Adaptors available for LGXI/NGXI and GU series Flowmeters

VA

LVES

+43 1 706 43 000 71

Page 70: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

NEEDLE VALVES

Valve Body Carbon Steel or 316 Stainless SteelSpindle Seal PTFEConnection/Threads BSP parallel or NPT threadValve Configuration Female to femaleOperating Pressure Max 6000 psiTemperature -20°C to 100°CCv 0.46 max (5.4mm orifice)

• Bubble tight metal to metal seat for positive shut off

• Unique bonnet locking cam.No accidental removal of head unit,or loosening due to vibration

• Bi-directional flow, with preferredflow indicated

2, 3 & 5 Valve ManifoldsA range of two, three and five valvemanifolds ideal for remote or directfitting to pressure gauges, switchesor transmitters. All units combineisolating, calibration or re-calibrationfacilities in one compact unit, withclearly marked valves for ease ofidentification and safe operation.

• Bubble tight shut off

• Metal to metal bonnet seal for highpressure and high temperature use

• Repair / service kit available to extend field life further

Body Type Pipe BSPP Thread NPT ThreadSize Code Code

Carbon steel 1/4" F49410301 F49410306Carbon steel 3/8" F49410302 F49410307Carbon steel 1/2" F49410303 F49410308Carbon steel 3/4" F49410304 F49410309Carbon steel 1" F49410305 F49410310SS 1/4" F49420301 F49420306SS 3/8" F49420302 F49420307SS 1/2" F49420303 F49420308SS 3/4" F49420304 F49420309SS 1" F49420305 F49420310

T - Bar ValvesA range of fine control valves, suitablefor control of high pressure flow linesup to 6000 psi. The non-rotating, selfcentreing, anti-galling spindle tip givespositive bubble tight shut-off, plusgood flow control.

Body 316 Stainless SteelProcess Connections 1/2" NPTValve Configuration Refer to product codesWorking Pressure Max 6000 psiSeals PTFEMounting Bolts M10 (3 and 5 valve only)Temperature -20°C to 100°C

Type Valve Configuration Code2 Valve Female x Female FVVA00802 Valve Female x Male FVVA00813 Valve Female x Female F494303005 Valve Female x Female F49430301

• Please specify mounting option required

• For BSP process connections, consult our Technical Sales Team for details

Specification

Product Codes

Specification

Product Codes

VA

LVES

www.mess-regeltechnik.at72

Page 71: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Ambient Temp -20°C to 55°CFluid Temp -10°C to 120°CViscosity Max 37 cSt, 5°EBody Brass with Stainless Steel

inner portSeals VitonCoil Voltage 12V and 24Vdc, 24V,

110V and 230VacVoltage Tolerance ± 10% (+10% -5% on pure DC)Power Consumption 8 Watts AC/DCDuty Cycle 100% continuous ratingProtection IP65Response Time 10 to 30ms

SOLENOID VALVES

Ambient Temp -20°C to 55°CFluid Temp -10°C to 90°CViscosity Max 37 cSt, 5°EBody Brass with Stainless Steel

tube and tube nutSeals NBR BunaCoil Voltage 12V and 24Vdc, 24V,

110V and 230VacVoltage Tolerance ±10% (+10% -5% on pure DC)Power Consumption 8 Watts AC/DCDuty Cycle 100% continuous ratingProtection IP65Response Time 10 to 30ms

3 Way Direct ActingA three way direct acting solenoidvalve for on/off control of non-aggressive fluids and gases such as air,oil or water. Model 80C has normallyclosed switching and is suppliedcomplete with exhaust port.

Size Orifice Pressure Coil Code*BSPP Size Range

(bar)

1/8" 2.5mm 13 12Vdc F594201234*1/8" 2.5mm 13 24Vdc F594201235*1/8" 2.5mm 20 24Vac F594201236*1/8" 2.5mm 20 110Vac F594201237*1/8" 2.5mm 20 230Vac F594201238*1/4" 2.5mm 13 12Vdc F594201239*1/4" 2.5mm 13 24Vdc F594201240*1/4" 2.5mm 20 24Vac F594201241*1/4" 2.5mm 20 110Vac F594201242*1/4" 2.5mm 20 230Vac F594201243*3/8" 4.5mm 0.9 12Vdc F594201244*3/8" 4.5mm 0.9 24Vdc F594201245*3/8" 4.5mm 4.5 24Vac F594201246*3/8" 4.5mm 4.5 110Vac F594201247*3/8" 4.5mm 4.5 230Vac F594201248*1/2" 4.5mm 0.9 12Vdc F594201249*1/2" 4.5mm 0.9 24Vdc F594201250*1/2" 4.5mm 4.5 24Vac F594201251*1/2" 4.5mm 4.5 110Vac F594201252*1/2" 4.5mm 4.5 230Vac F594201253*

* Add suffix A for normally closed or B for normally open

2 Way Direct ActingA direct acting two way solenoidvalve with options for normally open(B) or normally closed (A) for on/offcontrol of non-aggressive fluids andgases such as air, oil or water.

Port Size Pressure Coil CodeBSPP Range (bar)1/8" 10 12Vdc F59542012501/8" 10 24Vdc F59542012511/8" 10 24Vac F59542012521/8" 10 110Vac F59542012531/8" 10 230Vac F59542012541/4" 10 12Vdc F59542012551/4" 10 24Vdc F59542012561/4" 10 24Vac F59542012571/4" 10 110Vac F59542012581/4" 10 230Vac F5954201259

Specification

Specification

Product Codes

Product Codes

VA

LVES

+43 1 706 43 000 73

Page 72: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

SOLENOID VALVES

Ambient Temp -20°C to 55°CFluid Temp -10°C to 90°CViscosity Max 21 cSt, 3°EBody Brass with Stainless Steel

and Brass internal partsSeals NBR BunaCoil Voltage 12V and 24Vdc, 24V,

110V and 230 VacVoltage Tolerance ± 10%Power Consumption AC: 28VA impulse,13VA hold

DC: 8WDuty Cycle 100% continuous ratingProtection IP65

Servo-Acting CoupledDiaphragmSimilar in design to servo-actingmodel. This normally closed valve isable to operate at zero pressure andwithout a differential. This is achievedby mechanically coupling the plungerto the diaphragm, overcoming theproblems associated withgravity feed and circulatingsystems.

Suitable for non-aggressive fluids and gases.

Port Orifice Pressure Coil CodeSize Size Range BSPP (bar)3/8" 12mm 0.2 - 20 12Vdc F59542012603/8" 12mm 0.2 - 20 24Vdc F59542012613/8" 12mm 0.2 - 20 24Vac F59542012623/8" 12mm 0.2 - 20 110Vac F59542012633/8" 12mm 0.2 - 20 230Vac F59542012643/4" 19mm 0.2 - 16 12Vdc F59542012653/4" 19mm 0.2 - 16 24Vdc F59542012663/4" 19mm 0.2 - 16 24Vac F59542012673/4" 19mm 0.2 - 16 110Vac F59542012683/4" 19mm 0.2 - 16 230Vac F59542012691" 25mm 0.2 - 16 12Vdc F59542012701" 25mm 0.2 - 16 24Vdc F59542012711" 25mm 0.2 - 16 24Vac F59542012721" 25mm 0.2 - 16 110Vac F59542012731" 25mm 0.2 - 16 230Vac F59542012741 1/2" 40mm 0.2 - 10 12Vdc F59542012751 1/2" 40mm 0.2 - 10 24Vdc F59542012761 1/2" 40mm 0.2 - 10 24Vac F59542012771 1/2" 40mm 0.2 - 10 110Vac F59542012781 1/2" 40mm 0.2 - 10 230Vac F5954201279

Servo-ActingA servo-acting solenoid valve foron/off control of non-aggressivefluid, such as air, oil or water. Availableas normally closed switching, thisvalve requires a minimum pressuredrop of 0.2 bar for satisfactoryoperation ie. backpressure on thedownstream port.

Ambient Temp -20°C to 55°CFluid Temp -10°C to 90°CViscosity Max 21 cSt, 3°EBody BrassSeals NBR BunaCoil Voltage 12V and 24Vdc, 24V,

110V and 230VacVoltage Tolerance ±10%Power Consumption 3/8" and 1/2" : 8 Watts

3/4" & 1" : 14 WattsDuty Cycle 100% continuous ratingProtection IP65

Port Orifice Pressure Coil CodeSize Size RangeBSPP (bar) 3/8" 12mm 0 - 7 24Vdc F59542012803/8" 12mm 0 - 14 24Vac F59542012813/8" 12mm 0 - 14 110Vac F59542012823/8" 12mm 0 - 14 230Vac F59542012833/8" 12mm 0 - 7 24Vdc F59542012843/8" 12mm 0 - 14 24Vac F59542012853/8" 12mm 0 - 14 110Vac F59542012861/2" 12mm 0 - 14 230Vac F59542012873/4" 19mm 0 - 14 24Vac F59542012883/4" 19mm 0 - 14 24Vdc F59542012893/4" 19mm 0 - 14 110Vac F59542012903/4" 19mm 0 - 14 230Vac F59542012911" 25mm 0 - 14 24Vdc F59542012921" 25mm 0 - 14 24Vac F59542012931" 25mm 0 - 14 110Vac F59542012941" 25mm 0 - 14 230Vac F5954201295

Specification

Product Codes

Specification

Product Codes

VA

LVES

www.mess-regeltechnik.at74

Page 73: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

VA FLOWMETER SIZING DATA

Liquid Density CorrectionSizing for Liquids

For Volumetric Flow At Standard Reference

Condition Of 20°C

Definition of Sizing Factor (K)

Water equivalent flowrate:

Q1 = Sizing Factor (K) x max Liquid Flow Q2

i.e. Q1 = K x Q2

Max Flow liquid Q2 = Q1 (water equiv. flow)

Sizing Factor (K)

Sizing Factor(K) = 6.96 x X2

7.96 - X2

Where X2 = Liquid density at working conditions (g/cm3)

Example 1

To establish water equivalent flowrate and tube float

combination for:

1.5 l/min paraffin, working density 0.80 g/cm3

Sizing factor (K) = 6.96 x 0.80 = 0.882

7.96 - 0.80

Water equivalent Q1 = 0.882 x 1.5 = 1.323 l/min

Nearest standard range = 200 to 1500 cm3/minusing GTF 2ASS Tube & Float

Equivalent paraffin flowrate =

200 (min) to 1500 (max)

0.882 0.882

i.e 227 to 1700 cm3/min paraffin

Select meter type from VA Flowmeter section ofcatalogue.

The flowmeter can then be supplied calibratedfor: 0.2 to 1.7 L/min of paraffin.

For Gravimetricunits (e.g. g/min)

multiply scalereading of water

flow rate (insame units) by

factor:

0.7970.8260.8550.8810.9070.9320.9550.9781.0001.0211.0411.0611.0801.0981.1151.1321.1491.1651.1801.1951.2091.2231.2371.2501.2621.2741.2861.2981.309

Liquiddensity(g/cm3)

0.600.650.700.750.800.850.900.951.001.051.101.151.201.251.301.351.401.451.501.551.601.651.701.751.801.851.901.952.00

For Volumetricunits (e.g.

l/min) multiplyscale reading ofwater flow rate (in same units)

by factor:

1.3281.2711.2211.1751.1341.0961.0621.0301.0000.9720.9470.9220.9000.8780.8580.8390.8210.8030.7870.7710.7560.7410.7270.7140.7010.6890.6770.6650.654

To select the correct size VA flowmeter for a specific application (liquid or gas) it is necessary to convert therequired flow to an equivalent air or water flowrate. The nearest standard range flowmeter can then beselected using the table shown on page 11.

TEC

HN

ICA

L

+43 1 706 43 000 75

Page 74: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

VA FLOWMETER SIZING DATA

Sizing for Gases Gas Density Corrections

For Volumetric Flow At Standard Reference

Conditions Of 20°C And 1.013 bar abs. (ATP)

Definition of Sizing Factor (K):

Air equivalent flowrate

(F1) = Sizing factor (K) x Max gas flow (F2)

Note: F2 MUST BE EXPRESSED IN FREE

VOLUMES OF GAS (ie. MEASURED AT ATP)

Sizing factor (K) = r x T2 x 1.013

P2 293

Where:

r = Relative density of Gas to be measured

P2 = Absolute Operating Pressure (bar)

T2 = Gas Temperature (Kelvin)

Example 2

To establish equivalent air flowrate and suitable tube and float combination for 15 l/min acetylene(free volume measured at ATP) working at 5 bargand 40°C.

P2 = 1.013 + 5 = 6.013 bar Abs,

T2 = 273 + 40 = 313 K,

r = 0.898 (from reference table)

Sizing Factor (k) = 0.898 x 313 x 1.013 = 0.402

6.013 293

Equivalent Air Flow: F1 = 15 x 0.402 = 6.03 l/min

Nearest standard range = 1 to 10 l/min Air tube for G Series

Flowmeter, GTF 2BHS Tube & Float.

Equivalent Acetylene Flowrate = 1(min) to 10(max)

0.402 0.402

ie. 2.29 to 24.88 l/min Acetylene @ 5barg

Select meter type from VA Flowmeter section of catalogue.

The flowmeter can then be supplied calibrated for:25 L/min of acetylene at 40°C and 5 bar G.

Flowmeter scales can be infinite in variety due to thediffering physical properties of gases and their operatingconditions. Standard tubes for gases are calibrated foratmospheric pressure at the flowmeter outlet. If theworking outlet pressure (P) is different, the scale reading(expressed at ATP) should be corrected by using the formulae:-

Actual flowrate (@ATP) = P (Bar Abs.) x Scale reading

1.013

Actual flow rate(@ workingpressure P) = 1.013 x Scale reading

P (Bar Abs.)

Notes:1. Density and pressure correction factors should not

be applied to the lowest flowrate tubes (Frame Size 1) -consult RM&C sales.

2. Tubes with scales for different operating pressuresand calibration conditions are available to order.

Gas Chemical Relative Sizing

Formula Density Factor

(Air = 1) K

Acetylene C2H2 0.898 0.948Ammonia NH3 0.588 0.767Argon A 1.380 1.175Butane C4H10 2.007 1.417Carbon Dioxide CO2 1.520 1.233Carbon Monoxide CO 0.967 0.983Chlorine Cl2 2.450 1.565Cyclopropane C3H6 1.453 1.205Ethane C2H6 1.038 1.019Ethylene C2H4 0.968 0.984Helium He 0.138 0.371Hydrogen H2 0.0695 0.264Hydrogen Chloride HCl 1.259 1.122Hydrogen Sulphide H2S 1.177 1.085Methane CH4 0.554 0.744Neon Ne 0.697 0.835Nitrogen N2 0.968 0.984Nitrous Oxide N2O 1.520 1.233Oxygen O2 1.105 1.051Propane C3H8 1.522 1.234Sulphur Dioxide SO2 2.210 1.487

To convert ATP air flow rates to ATP flow rates of the selectedgas, divide by sizing factor K:

TECH

NIC

AL

1. RM&C expresses gas volumes at ATP (1.013 bar abs x 20ºC)2. Standard density of air @ ATP = 1.204 g/L

Notes:

www.mess-regeltechnik.at76

Page 75: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

UNIT CONVERSIONS & IP TABLE

To convert into multiply Reciprocalflows of by

Imp. Gal/hr l/min 0.07577 13.20

U.S. Gal/hr l/min 0.06308 15.85

Cu. Ft/hr l/min 0.4719 2.119

Imp. Pint/hr ml/min 9.471 0.1056

Barrels/hr m3/hr 0.1637 6.110

Imp. Fluid Oz/hr ml/min 0.4735 2.112

Pounds/hr g/min 7.560 0.1323

Imp. Gal/min m3/hr 0.2728 3.666

U.S. Gal/min m3/hr 0.2271 4.403

Cu. Ft/min m3/hr 1.699 0.5886

Pounds/min Kg/hr 27.22 0.03674

Litres/min m3/hr 0.06 16.67

Litres/sec m3/hr 3.6 0.278

ºC = (ºF - 32)

1.8

ºF = (1.8 x ºC) + 32

0ºC = 273.15K

Ingress Protection (IP) codes - (IEC/EN 60529)

First Numeral Second NumeralSOLID BODIES LIQUIDS

No protection 0 0 No protectionObjects greater than 50mm 1 1 Vertically dripping waterObjects greater than 12mm 2 2 Angled dripping water -75ºC to 90ºCObjects greater than 2.5mm 3 3 Sprayed waterObjects greater than 1.0mm 4 4 Splashed water

Dust-protected 5 5 Water jetsDust-tight 6 6 Heavy seas

7 Effects of immersion8 Indefinite immersion

Example: IP65 equipment is dust-tight and protected against water jets

To convert into multiply Reciprocalby

Imp. Gallons Litres 4.5460 0.21997

U.S. Gallons Litres 3.7854 0.26417

Imp. Pint Litres 0.56826 1.7598

Cubic feet Litres 28.316 0.035315

Cubic Centimetre Millilitres 0.999973 1.000027

Cubic Inch Millilitres 16.387 0.061024

Imp. fluid ounce Millilitres 28.413 0.035195

Cubic Metre Litres 1000 0.001

Pound Kilogrammes 0.45359 2.2046

Ounce Kilogrammes 0.028349 35.274

Imp. Ton Tonne 1.01605 0.98421

To convert into multiply Reciprocalby

inch H2O millibar 2.491 0.4015

psi millibar 68.95 0.014504

inch Hg millibar 33.86 0.02953

KPa (KN/m2) millibar 10 0.1

Atm bar 1.0132 0.9869

Kg/cm2 bar 0.9807 1.0197

Kg/cm2 psi 14.22 0.07031

psi Atm 0.06805 14.696

psi inch H2O 27.68 0.03613

N/cm2 KPa (KN/m2) 10 0.1

TEC

HN

ICA

L

Flowrates Mass & Volume

PressureTemperature

+43 1 706 43 000 77

Page 76: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

Product Codes

PRESSURE OVERVIEW

RM&C Sensit• World Leader in ceramic strain gauge

technology since 1988

• The only UK company manufacturingceramic pressure sensors

• A full range from low cost, ready to use pressure capsules to fully packaged pressure transducers and transmitters

Sensit’s experienced R&D team have a broad rangeof knowledge satisfying the requirements of manydifferent applications including:

Pressure Measurement

OEM Inkjet PrintersAutomotive Engine TestOff Highway VehiclesHydraulic/Pneumatic SystemsPulp/Paper ProductionWaste WaterSewage TreatmentReservoir/River LevelBorehole Level

Tank Level/MarineTrain BrakingOil ExtractionCable ProtectionMilking SystemsMedical EquipmentMeteorologyOceanography

PR

ESSUR

E

www.mess-regeltechnik.at78

Page 77: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

PRESSURE OVERVIEW

OEM CeramicPressure Sensors• Chemical & corrosion resistance

• Size to suit application - Ø15mm,Ø19mm and Ø34mm

• Pressures: 0-100mbar to 0-1000bar

• Temperatures: -25°C to 130°C

• Gauge or Absolute pressure

• Span 1.0 to 5.0 mV/V

• Custom interconnection

OEM Transducers

• Applications Engineering Support

• Improve design - reduce costs

• Customer specific design

• Ability to interpret customers’requirements

• Problem solving - broad expertise

• Quick delivery prototypes

Industrial PressureTransmitters• Accuracy 0.1% span

• Wide operating temperature range from -25°C to 125°C

• Robust - immune to shock

• Custom Electrical or process connections

• Intrinsically safe versionsavailable

• Output options: mA, mV or voltage

• Pressures: 100mbar to 600 bar

Submersible PressureTransmitters

• Small diameter

• Chemical & corrosion resistance

• Output: 4-20mA or 10mV/V

• Pressures: 1 to 500mWG

• Temperatures: -10°C to 60°C

• Power supply: 2.5 to 32Vdc

• Lightning protection

Pulp & Paper FlushTransmitter

• Chemical & corrosion resistance

• Unrivalled abrasion resistance

• Pressures: 400mbar to 50bar G or Abs

• Temperatures: -25°C to 100°C

• Output: mA, mV or voltage

• Stainless steel case

• Anti-clogging

SlurryTransmitter

• Robust mechanical design

• Unrivalled abrasion resistance

• Pressures:5 to 100bar G or Abs

• Temperatures:-25°C to 100°C

• Output:mA, mV or voltage

• Stainless steel case

PR

ESSU

RE

+43 1 706 43 000 79

Page 78: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Pressure Range Span ±30% Order Code0-1 bar g 2.5 mV/V FM5070-001-460-10 bar g 4.0 mV/V FM5070-010-460-20 bar g 4.5 mV/V FM5070-020-46

TRANSMITTERS

Specification

Product Codes

mV TransducerEconomic OEM mV sensor designedfor installation inside industrialequipment & machinery. Ideally suitedto battery powered equipmentoperating from 2.5V & with 1mSresponse time. The OEM transducercombines Sensit’s high purity ceramicpressure sensor technology withpassive signal conditioning to provide atemperature compensated mV output.

Specification

Product Codes

General Purpose2-wire, 4 to 20mA uncompensatedpressure transmitters based on a fouractive arm strain gauge bridge, fusedto a high-purity alumina ceramicdiaphragm, offering high naturaloutput coupled with superb chemicaland corrosion resistance. This ishoused within a Stainless Steel caseand supplied with a plug and socket.

Process Connection 1/4" BSP male (G 1/4) Pressure Ranges 0.5 to 600 bar gauge or AbsoluteOutput 4 to 20mA, loop poweredLoop Supply 10 to 30 VdcLoop Resistance 1KΩ @30VNL&H* <±0.25% of spanOperating Temp 0 to 80oCThermal Shift Zero ±0.08% of span/oC typical

Span ±0.04%/oC typicalSafe Over-pressure 1.5 x rated rangeWetted Materials Alumina ceramic, SS & VitonProtection IP65Electrical Connection DIN 40050 Micro-connector

* includes non-linearity, hysteresis & repeatability

Range Order Code Gauge(bar) Absolute0 to 1 FM6420-001A-50 FM6420-001G-500 to 2 FM6420-002A-50 FM6420-002G-500 to 3 FM6420-003A-50 FM6420-003G-500 to 5 FM6420-005A-50 FM6420-005G-500 to 10 FM6420-010A-50 FM6420-010G-500 to 20 FM6420-020A-50 FM6420-020G-500 to 50 - FM6420-050G-500 to 100 - FM6420-100G-500 to 200 - FM6420-200G-500 to 400 - FM6420-400G-50

TRA

NSM

ITTER

S

www.mess-regeltechnik.at80

Output 2.5 to 4.5mv/V ratiometricNL, H & R ±0.15% spanThermal zero shift <±0.015% span/ºCThermal span shift <±0.015% span/ºCTemp range 0ºC to 80ºCLong term stability: ±0.25% span/year

Data Sheet 2902

Data Sheet 2810

Page 79: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

TRANSMITTERS

Output: 4 to 20mA, 0 to 100mV,0 to 5V

Setting accuracy: ± 0.5% spanNL, H & R: ± 0.1% spanTemp range: -20ºC to +125ºCThermal zero shift: ± 0.015%/ºCThermal span shift: ± 0.015%/ºC typicalLong term stability: 0.1% span/yearIntrinsically Safe: Ex

HPS SeriesHigh performance pressuretransmitters offering unrivalledchemical & corrosion resistance.Gauge or absolute pressure isaccurately measured using a fouractive-arm strain gauge bridge sensorfused to a high-purity ceramicdiaphragm. Available with mV,voltage ormA output.

* note for intrinsically safe option add to order code

Specification

Product Codes

Output 4 to 20mA or 0.5 to 4.5VNL, H & R ± 0.5% spanThermal error ± 0.5% span, (1% for 1 bar range)

Temp range -40ºC to +105ºCLong term stability ± 0.25% span/yearEMC 100V/mVibration 20g, 10 to 2000 Hz Sinusoidal, 3 axesBody Diameter 22mm

Specification

Product Codes

Pressure Output Std IntrinsicallyRange Safe0-1 bar g 10m V/V FC-FHVAA-0010-1 bar abs 10m V/V FC-FHVAA-001A0-10 bar g 10m V/V FC-FHVAA-0100-100 bar g 10m V/V FC-FHVAA-1000-1 bar g 4-20mA FA-AHVAA-001 FA-KHVAA-0010-1 bar abs 4-20mA FA-AHVAA-001A FA-KHVAA-001A0-10 bar g 4-20mA FA-AHVAA-010 FA-KHVAA-0100-100 bar g 4-20mA FA-AHVAA-100 FA-KHVAA-1000-400 bar g 4-20mA FA-AHVAA-400 FA-KHVAA-4000-1 bar abs 0-5V FA-BHVAA-001A0-10 bar g 0-5V FA-BHVAA-0100-100 bar g 0-5V FA-BHVAA-1000-400 bar g 0-5V FA-BHVAA-400

4-20mA (Packard)Pressure Range Code0-1 bar g FEIT-001G-AB-XXXX-20mA0-1 bar abs FEIT-001A-AB-XXXX-20mA0-10 bar g FEIT-010G-AB-XXXX-20mA0-100 bar g FEIT-100G-AB-XXXX-20mA0-200 bar g FEIT-200G-AB-XXXX-20mA

0.5V - 4.5V (300mm cable)Pressure Range Order Code0-1 bar g FEIT-001-G-AB-I12-4.5V0-1 bar abs FEIT-001-A-AB-I12-4.5V0-10 bar g FEIT-010-G-AB-I12-4.5V0-100 bar g FEIT-100-G-AB-I12-4.5V0-200 bar g FEIT-200-G-AB-I12-4.5V

TRA

NSM

ITTE

RS

+43 1 706 43 000 81

Data Sheet 2805

Economic Industrial TransmittersCompact & robust, gauge and absolute,stainless steel transmitters. ASIC signalconditioning provides high accuracyover wide operating temperaturerange. Available with 0.5V to 4.5V ratio-metric output and integrated cable forOEM applications or 4 to 20mA andPackard connector for industrialapplications.

Data Sheet 2703

Page 80: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

PROCESS MEASUREMENT & CONTROLS Inc.

• Established in 1963 - process specific to thePulp and Paper industry

• Produced in a modern facility that uses high-tech equipment designed and built in house

• Quality is assured by uncompromising attention to manufacturing details and calibration procedures

Pressure Products• Precision solutions for Pressure, Level and

Vacuum measurement

• Pneumatic and electronic transmitters for pulp and water, food and beverage, pharmaceutical and wastewater management

• All stainless steel housing available

Pressure Measurement• Patented flush-mounted transmitters

• Anti-clogging

• Industry standard

• Rugged and reliable

Process Measurement & Controls

PMC

PM

C

www.mess-regeltechnik.at82

Page 81: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

PROCESS MEASUREMENT & CONTROLS Inc.

Pneumatic (1:1)

PMC Miniature Pressure and LevelTransmitters accurately measure pres-

sure and levels in process industries

where plugging of gauges and seals is a

problem. The small diameter of the

transmitter permits installation flush

with the inside wall of pipes 1" and larger.

This feature avoids the usual pocketing

problems encountered with conventional

flange-mounted transmitters. This PMC

product is well suited for high vibration

environments and is ideal where limited

access is a concern.

SpecificationRanges 0-10:30: 60: 100 & 150 PSIG Level 0-10: 25:50: 100: 300 & 500" WGOutput 1:1, 3-15 PSIGAccuracy +/- 0.1 PSIG Mounting Weld-on + othersDiaphragm Havar, Hastelloy C or TantalumTemperature -25ºC to 85ºC

Product Codes

PT-XXX-N-Ha-SPT/SAN-XXX-Si-Ha-HTLT/DR-XXX-N-Ha-SLT-SAN-XXX-Si-Ha-HT

Electronic (4-20mA)

PMC Electronic TransmittersThe capacitance sensor handles over-

loads of up to 10 times nominal range.

The Slimline version offers a compact

design for installation in confined

spaces and measures just 1 1/16"

diameter by 4" long. The remote

electronics version offers a split unit

where the transducers are submerged and

the electronics are mounted in an acces-

sible location for calibration, with a local

display (LCD) option.

SpecificationRanges 4.25" WG to 300 PSIG 30 & Vacuum Output 4-20mAAccuracy +/- 0.25%Mounting Weld-on + othersDiaphragm Havar, Hastelloy C Tantalum or

CeramicTemperature -25ºC to 85ºC

Product Codes

PTEL-SAN-XXX-Ha-CV/PPT/EL-DR-XXX-Ha-CV/PMINI-PT/EL-SAN-XXX-Ha-CV/PMINI-PT/EL-SAN-XXX-Ha-CV/P

PR

ESSU

RE

XXX = pressure range

+43 1 706 43 000 83

Page 82: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

Product Codes

Measuring element Piezoresistive pressure sensor with stainless steeldiaphragm, microcontroller and self monitoring

Measuring ranges 0 to 10 bar - 0 to 600 barLinearity error 0.5% fsDisplay 3 digit 7-segment LED display, red, 10mm heightOutput signals 4-20 mASwitching outputs Solid state outputs pnp-NO/NC (programmable),

adjustable switching line delay 0 to 10 sTemp drift of zero signaland output (ref 20°C) 0, 2%/10k from 10°C to +70°CTemperature range -10°C to +70°CMedia temperature range -25°C to +100°CProcess connection G 1/4 M, stainless steel, optional C-Top flange

connectionProtection class IP 65Electrical connection Plug 4-pin M 12 x 1Process connection G 1/4 M, stainless steelPower supply 15 to 32 VdcOptions on request

Pressure range 0 to 10 bar 0 to 50 bar 0 to 100 bar 0 to 200 bar 0 to 400 bar 0 to 600 bar

1 Switching Output F0428-011 F0428-012 F0428-013 F0428-014 F0428-015 F0428-0162 Switching Outputs F0428-017 F0428-018 F0428-019 F0428-020 F0428-021 F0428-0221 Analogue Output 4-20 mA F0428-127 F0428-128 F0428-129 F0428-130 F0428-131 F0428-132

DESIGNA®1 Switching Output F0428-031 F0428-032 F0428-033 F0428-034 F0428-035 F0428-0361 Diagnosis Output

Accessories CodeAdapter G 1/4 F - G1/4 M thread or optimum alignment of pressure switch F0499-016Damping screw with 0.2mm restriction against quick pressure changes and high pulsation rate F907-0677Electrical plug M 12 x 1, 4-pin, with screw terminal, 90º elbow F907-0357Electrical plug M 12 x 1, 4-pin, with screw terminal, straight F907-0344

ELECTRONIC PRESSURE SWITCH

Switch 2000• Electronic pressure switch with 1 or 2 solid state contacts

• 7-segment LED display

• Microprocessor controlled

• Self monitoring with error display, all parameters are configured by keypad,tamper proof keypad lock, rugged construction, vibration and shock-proof

• Good long term stability

OEM Applications

• Hydraulics

• Pneumatics and lubrication monitoring

• Machine/machine tool industry

• Automobile industry

• Injection molding machines

PR

ESSUR

E

www.mess-regeltechnik.at84

Page 83: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

UDS2 2-V2 Switch• Two transistor-switching contacts

• Switch contact indication with two LEDs

• Switch point/parameter adjustment with PC interface or hand-held terminal

• Mechanically robust and reliable

PRESSURE SWITCHES

Measuring Element Thick film ceramic sensorRange 2,0 to 400 bar, gaugeLinearity error <±1% fsDisplay Switch status by 2 LED,

green/yellowSwitching output 2 solid state outputs, pnp -

NO/NC, freely adjustableTemp range -25°C to 85°CMedia temp range -25°C to 85°CProcess connection G 1/4 M, stainless steelProtection class IP67Elect connection Plug 5-pin M 12 x 1Power supply 12 to 30 VdcOptions on request

Measuring Range 2 switching outputs

0 - 10 F0429-0010 - 50 F0429-0020 - 100 F0429-0030 - 200 F0429-0040 - 400 F0429-005

AccessoriesProgramming kit F0499-031Hand-held programmer F0499-032

Output SPCO contactsContact Rating 250Vac/4A (resistive)ProcessConnection 1/4" BSP Male (G 1/4")Elect Connection IP65 plugTemperature -30°C to 120°CPressure 100 bar on 1.5 and 10 bar steel

units; 300 bar on all others up to 100bar; 600 bar on 200 bar units

Dimensions 27mm AF, 26mm ODCable Gland Pg 9Hysteresis 10 to 30% of max, switch point,

adjustableWetted Materials Viton diaphragm/piston seal

and zinc-plated steel or StainlessSteel body

• Ideal for hydraulics and pneumatics

• Change-over contacts

• Compact design

Adj Range (bar) Tol.(bar) Zinc Plated Steel Stainless Steel

0.3 - 1.5 ±0.2 FSUCO457031 -0.5 - 5 ±0.2 - FPSW00211 - 10 ±0.5 FSUCO458031 FPSW002210 - 50 ±3 FSUCO459031 FPSW002310 - 100 ±3 FSUCO461031 FPSW002450 - 200 ±5 FPSW0020 FPSW0025

Pressure SwitchAdjustable diaphragm and pistontype pressure switches, suitable forgases and liquids. Available in zinc-plated steel and stainless steel bodymaterials.

Specification

Product Codes

Specification

Product Codes

PR

ESSU

RE

+43 1 706 43 000 85

Page 84: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

PRESSURE GAUGES

Pressure GaugesThe Stainless Steel Pressure Gauges of the MEX and MIX range, have been designedfor use across the measurement and control industry. The gauges are perfectly suited tothe process industries such as chemical, petro-chemical, energy and gas, as well asfood and brewing applications.

• All Stainless Steel gauges

• Robust for harsh environments

• Resistance to transient overpressure

• Conforms to EN837 and PED standard

Typical industries serviced by these gauges• Chemical

• Energy generation

• Pharmaceutical

• Food processing

• Brewing

• Bio-technology

• Nuclear

In addition to our standard range we are ableto offer a much wider range of pressuregauges as well as all the accessories yourapplication requires.

Available spares and accessories

• Pressure limiters

• High temperature adapters

• Gauge cocks and valves

• Dampeners

• Siphons

• Hygienic and chemical seals

Please contact our Technical Sales Team todiscuss your spares and accessory requirements.

GA

UG

ES

www.mess-regeltechnik.at86

Page 85: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

PRESSURE GAUGES

Specification

Product Codes

Diameter 50mm (MEX2)63mm (MEX3)100mm (MEX5)

Mounting Direct bottom entryCase 1.4304 (AISI 304) Blow out disk on topWetted Parts 1.4404 (AISI 316L)Window Plain glassConnection 1/4" BSP as standard or NPT (M) (MEX2 + 3)

1/2" BSP as standard or NPT (M) (MEX5)Weatherproof IP65Accuracy +/- 1.6% FSD (MEX2 + 3)

Class 1 (MEX5)

Diameter 150mm (MIX)Mounting Direct bottom entryCase 1.4304 (AISI 304) Blow out disk on topWetted Parts 1.4404 (AISI 316L)Window Plain glassConnection 1/2" BSP or NPT (M) Weatherproof IP65Accuracy Class 1

Range bar 50mm Code 63mm Code

-1 to 0 bar FMEX2000* FMEX3000*0 to 1 bar FMEX2001* FMEX3001*0 to 2.5 bar FMEX2002* FMEX3002*0 to 4 bar FMEX2004* FMEX3004*0 to 6 bar FMEX2006* FMEX3006*0 to 10 bar FMEX2010* FMEX3010*0 to 16 bar FMEX2016* FMEX3016*0 to 25 bar FMEX2025* FMEX3025*0 to 40 bar FMEX2040* FMEX3040*0 to 60 bar FMEX2060* FMEX3060*0 to 100 bar FMEX2100* FMEX3100*

100mm Code 150mm Code

FMEX5000* FMIX7000*FMEX5001* FMIX7001*FMEX5002* FMIX7002*FMEX5004* FMIX7004*FMEX5006* FMIX7006*FMEX5010* FMIX7010*FMEX5016* FMIX7016*FMEX5025* FMIX7025*FMEX5040* FMIX7040*FMEX5060* FMIX7060*FMEX5100* FMIX7100*

* For a glycerine filled gauge add ‘G’ to the end of the product code* Add suffix ‘DS’ for dual scale gauge (bar/psi)

• psi and other ranges available on request, please contact our Technical Sales Team for details

GA

UG

ES

+43 1 706 43 000 87

Page 86: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

Product Codes

DP GAUGES

Low DP GasesThe Magnehelic® gauge uses magnetic coupling from the movement of a siliconrubber diaphragm onto a helical pointer drive shaft. This measurement is frictionfree, accurate at very low differential pressures, and resistant to shock and vibration.The standard aluminium housing can be flush panel mounted. Pressure connectionsare duplicated on rear and side of the unit. Plugs and tube barbs supplied.

Magnehelic® Accessories• Pipe mounting kit

• Line filter

• Portable kit

• Safety relief valve

• Air filter kit

Ranges Pascals, mm or inch WG, pitot flowMedia Air & non-corrosive gasesAccuracy ±2% FSDPressure 15 psig maxTemperature -7°C to 60°CConnections 1/8" NPT Female. Plugs and

adaptors for 5mm ID tube supplied

Housing Die-cast AluminiumDiaphragm Silicon rubber, overpressure

protectedZero Adjust Screw Mounted in meter facePanel Cut Out 115mm diameterWeight 0.5kg

Water (inches) Code Pascals Code

0-1 FM2001 0-60 FM200060PA0-2 FM2002 0-100 FM2000100PA0-4 FM2004 0-125 FM2000125PA0-5 FM2005 0-250 FM2000250PA0-10 FM2010 0-500 FM2000500PA0-15 FM2015 0-750 FM2000750PA0-20 FM2020 0-1K FM20001KPA0-50 FM2050 0-1.5K FM20001.5KPA

0-2K FM20002KPA0-5K FM20005KPA

Water (mm) Code

0-50 FM200050MM0-100 FM2000100MM0-250 FM2000250MM0-500 FM200050CM

Centre Zero Pascals Code

30-0-30 FM230060PA60-0-60 FM2300120PA125-0-125 FM2300250PA

GA

UG

ES

www.mess-regeltechnik.at88

Page 87: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

DP GAUGES

DP Ranges Pascals (See order codes)Accuracy ±2% FSDMedia Air & non corrosive gasesHousing Die-cast AluminiumProcess Connections 1/8" NPT Female (rear & side)Max Pressure 25 psigTemperature -5°C to 50°CPower Supply 24VdcOutput 2 x SPDT relays, 1 Amp @

30Vdc, 0.5 Amp at 125VacElectrical Connection 460mm 8 core cablePanel Cut Out 123mm diaOverall Size 140mm dia. x 65mm deepWeight 0.75Kg

DP Gauge With TransmitterThe standard easily readMagnehelic® dial gauge gives localindication of very low differentialpressures in air or gas applications.Additionally a two-wire 4 - 20mAtransmission is provided from a builtin strain gauge DP monitor, allowingremote monitoring or control. Spanand zero adjustments are madewith a special tool (supplied), andthe unit can be flush panel mountedusing the hardware supplied.

DP Range (Pascals) Code

0-60 F3000MR600-125 F3000MR1250-250 F3000MR2500-500 F3000MR5000-1000 F3000MR1000

DP Gauge With AlarmsBased on the Magnehelic® design,this gauge retains the low DPsensitivity and accuracy - and addstwo relay outputs for high & low DPalarms. The Photohelic® principleuses the standard gauge pointer tointerrupt infra-red beams at theadjustable set points, which thendrive the output relays. High andlow set points are adjustable usingthe front mounted knobs.

DP Ranges Pascals or inch WGOutput 4 - 20mA loop powered

(10-35Vdc)Accuracy ±2% FSDMedia Air and non corrosive gasesHousing Die-cast AluminiumConnections 1/8" NPT FemalePressure 25 psig max (varies by range)Temperature 0 to 50°CPanel Cut Out 123mm diaOverall Size 140mm dia. x 65mm deepWeight 1.14Kg

DP Range Code DP Range Code(Pascals) (inches WG)0-60 F60560 0-0.5 F60500-125 F605125 0-1.0 F60510-250 F605250 0-2.0 F60520-500 F605500 0-3.0 F60530-750 F605750 0-6.0 F60560-1500 F6051500 0-10.0 F60510

0-20.0 F60520

Specification

Product Codes

Specification

Product Codes

GA

UG

ES

+43 1 706 43 000 89

Page 88: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

DP FLOW TRANSMITTERS

Specification

Product Codes

The Micro-Bar range are two-wire loop powered 4 - 20mA transmitters based on abuilt-in capacitance based differential pressure cell for low range measurement on airand other dry gases. Standard pressure connections are push-fit sockets but units arealso available with 1/4" NPTF threads or 6mm O/D stainless steel compression fittings.The liquid crystal display shows the measured pressure and status of the alarm out-puts. Alternatively, when used in conjunction with orifice plates, pitots or other DPbased flow sensors, units can be configured to provide root extraction of the pressuremeasurement to display flow rate. Two switch outputs are programmable as flow orpressure setpoints or, for flow measurement, toprovide a totaliser output pulse.

• Built in square root option

• Totaliser pulse output for all flowapplications

• Hi/Low volt-free contact outputs foralarm applications

• Adjustable averaging to smooth out flowfluctuations

Media Air and non-corrosive dry gasesProcess 2 x pushfit connectors for 4mm Connections OD tubing (1/4" NPTF available to

special order)Static Pressure For DP ranges >1000Pa: 30kPa max

For DP ranges >1000Pa: 10bar maxOver Range 5 times DP range maxTemperature 0 to 40ºCOutputs:

Current 4-20mA loop poweredSwitches Two volt-free solid-state relays (NO/NC)

110Vac/dc, 1 Amp max

Loop Supply 10 to 50VdcLoop Resistance 700W max @ 24VOutput Range Adjustable 20% to 100% of model

DP rangeFunctions Linear or square rootDisplay 2 line x 16 character LCDAccuracy ±0.5% of max DPProtection IP66ElectricalConnections 2 x M20 cable glands

Range Code0-30 Pa (0.1" WG) FMB0-DR-01-ST0-100 Pa (0.4" WG) FMB1-DR-01-ST0-150 Pa (0.6" WG) FMB1A-DR-01-ST0-300 Pa (1.2" WG) FMB2-DR-01-ST0-1000 Pa (4" WG) FMB3-DR-01-ST

Range Code0-3000 Pa (12" WG) FMB4-DR-01-ST0-10 KPa (40" WG) FMB5-DR-01-ST0-30 KPa (120" WG) FMB6-DR-01-ST0-1 Bar (400" WG) FMB7-DR-01-ST

Replace -ST with -CF for 6mm O/D stainless steel compression fittings

TRA

NSM

ITTER

S

www.mess-regeltechnik.at90

Data Sheet 1720

Page 89: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

REGULATORS

• Very high accuracy

• Capsule rather than rolling diaphragm

Electronic I/P ConvertersThese electro-mechanical instrumentsare designed to convert electricalcurrent to a pneumatic output. Theconverter is based upon the wellproven electro-magnetic force balancetechnique for consistent and reliableperformance.Model 100X is designedfor low pressure and model 101X issuitable for high pressure applications.Both are suitable for control room orfield mounting.

• ATEX certified units available

• Minimum vibration effects

• IP65 protection

• Mounting bracket and connector included

High Precision PressureRegulatorPrecision regulators are suitable forinstrumentation applications demandingparticularly accurate pressure regulation.These sophisticated precision controllerscan be used where exact repeatabilityand freedom from drift coupled withsuperior flow and regulation characteristicsare specified. Particularly suitable fordead end or low flow applications.

Accuracy ± 1%Response Time 1 second typicalTemperature -45°C to 85°CProtection IP65Flow Capacity 300 L/min (10SCFM)Connections 1/4" NPT femaleModel 100X Low PressureLinearity Error 0.5%Hysteresis 0.35%Input Pressure 1.4 - 4.5 bar (20-80 psig)0utput Pressure 0.2 - 1 bar (3-15 psig)Air Consumption 0.85 L/min (0.03 scfm)Input Signal 4-20mA 2-wireModel 101X High PressureLinearity Error 1%Hysteresis 0.5%Input Pressure 10 bar (150 psig) maxOutput Pressure 0.14-8 bar (3-120 psig)Consumption 1.75 L/min (0.06 scfm)Input Signal 4-20mA 3-wire

Type Code100X F59424101X F59425

•100X is also available approved to EEX ia IIC T4

Specification

Product Codes Product Codes

Specification

Body Die cast zinc alloy. Black vinylfinish

Diaphragm Nitrile rubberCapsule Stainless SteelMounting Any orientation in-line or panelPneumatic Conn. 1/4" NPTWeight 635gInput Pressure (max) 10 bar regulatedMedia Air or dry non corrosive gasFlow (mid range) 25m3/hrConsumption 0.15m3/hrExhaust Capacity 3.4m3/hr @ outlet 5 psi above

set pointSelf Venting Standard model is fitted with aHandwheel manually operated handwheel

for precise pressure adjustment

Pressure Range Code2-25 psi F592813122-60 psi F592813132-120 psi F59281315

REG

ULA

TOR

S

+43 1 706 43 000 91

Page 90: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

REGULATORS

Body Nickel plated BrassValve seat Stainless Steel AISI 304Spring Zinc coated Silicon steelO-Rings Anti-Ageing Nitrile rubber PB 701Gauge port 1/4" BSPMax Temp 70°CInlet Working 3/8 to 2" up to 15 barPressure 21⁄2" to 3" up to 25 bar

Water Pressure RegulatorNon-RelievingA range of general purpose non-relieving water pressure regulatorsfor use with potable and generalsalty water. UK water by-law schemelisted.

• Non-relieving

• Durable brass body construction

• Oil resistant rubber valve face

• Complete shut-off

• Recommended for water service lines

• Nylon reinforced synthetic rubberdiaphragm

BSPF Size Code3/8" F59197031/2" F59197043/4" F59197061" F591970811⁄2" F59197122" F59197163" F5919724

Pressure Reducing ValveThis brass pressure reducing valvefor non corrosive liquids is a low costregulator for 3/8" to 3" lines. Theadjustment in the base is via an Allenkey protected by a plastic cap. Apressure gauge can be used in thetop of the valve to monitor outletpressure.

Body BrassDiaphragm Synthetic rubberMaximum Flow Typically at 7 bar inlet,5.5 bar

outlet,pressure drop 1 bar - 3 L/minPort Size G1/4"Gauge Ports 2 x 1/8" BSPTMax Primary Pressure 28 barMax Temperature 80°C

Pressure range Code0.07 to 0.7 bar F487601020.07 to 3.5 bar F487601030.14 to 7.0 bar F48760104Panel mounting bracket with panel nut F48790104

Product Codes Product Codes

Specification Specification

• Adjustable outlet range 0.5 - 7 bar

REG

ULA

TOR

S

• 15 bar inlet pressure

• Protects againstwater hammer

• For water supply up to 80°C

www.mess-regeltechnik.at92

Page 91: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

REGULATORS

Specification

Product Codes

Pressure Relief ValveThis pressure relief valve for water, air,gas, steam or non-corrosive liquids isadjustable over the range 1 - 12 bar,using the top mounted screw and lock-nut. When line pressure exceeds thepreset value, the valve opens anddischarges to the drain line. Units areavailable for line sizes from 3/8" to 3"BSP.

Body Brass for sizes 3/8"- 1"Bronze for sizes 11⁄4" - 3"

Valve seat Brass and PTFESpring Zinc plated Carbon Steel C72Regulator BrassMax temp 180°CRelief Pressure 15 - 170 psi (1 - 12 bar)

BSPF (Size) Code3/8" F59198031/2" F59198043/4" F59198061" F5919808

BSPF (Size) Code11⁄2" F59198122" F59198163" F5919824

• Suitable for water, steam & non-corrosive liquids

• Teflon seat for maximum 180°C operation

• Adjustable relief pressure range1- 12 bar

• Compact design

Specification

Product Codes

Port sizes: G 1/4"Standard ports to ISO 1179.Accepts ISO 228 (BS2779) parallelor ISO 7 (BS 21) taper connectionsFor alternative threads consult factory

Non-relievingprimary pressures Up to 31.5 bar (450psi)

Regulated pressures* 0.7 to 8 bar (10 to 125 psi) standardOperating temp 2°C to 100°C (35°F to 212°F)Gauge ports G 1/8"

* will provide complete shut off

Type CodePanel mounting bracket/ring 487801010.07 to 0.7 bar 487601-020.07 to 3.5 bar 487601-030.14 to 7.0 bar 487601-04

Water Pressure RegulatorA range of water pressure regulatorssuitable for use on potable as well asgeneral duty water systems andmanufactured from National WaterCouncil approved materials

• Metal contact parts are dezincified brass, typeCZ 132 to BS 2872/2874 or stainless steel

• Balanced valve design ensures asmooth, quick response to sudden flow demands with low pressure drop

• Easy servicing without removal from water line

• Panel mounting facility

• Accessories includemetal panel mountbracket and nut

REG

ULA

TOR

S

+43 1 706 43 000 93

Page 92: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

Specification

Product Codes

TEMPERATURE OVERVIEW

RM&C Brearley• The UK’s largest manufacturer of thermocouples

and temperature probes

• Technical help desk for application solutions

• Standard and custom designs

• Full range of associated accessories

• Fast track system for urgent deliveries

Temperature Measurement• Mineral insulated thermocouples from -200°C to 1300°C

• Rare metal thermocouple assemblies up to 1800°C

• PT100/RTD thermocouples from -200°C to 550°C

• Non contact pyrometry up to 3000°C

Temperature Products• Controllers and displays

• Recorders and dataloggers

• Transmitters and signal conditioning

• Accessories and fittings

• Configuration, installation and commissioningTEM

PER

ATU

RE

www.mess-regeltechnik.at94

Page 93: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

TEMPERATURE OVERVIEW

TemperatureTransmitters

• Head or DIN rail mounted

• Thermocouple or Pt100

• 0/4-20mA output

• Intrinsically safe options

• Open HART® protocol

• Alarm relay option

Latis Level & TempMonitoring

• Combined temperature and water interface sensor for liquid tanks

• Single entry for two sensors

• Certified for hazardous area zone 1operation

• Calibration and maintenance free

• High level detection accuracy+/- 2mm

Infra-redThermometers

Controllers, Recordersand Dataloggers

Thermocouples

• Range -200°C to 1800°C

• All industries supplied

• All types manufactured

• Materials & componentsheld in stock

• In-house calibration

• Full repair service

Refractory Sheathsand Cables

• Sheaths/tubes up to 1800°C

• Excellent corrosion resistance

• Range of materials

• Cables to suit all thermocouples

• Colour coded to IEC 584-3

• Ex-stock

• Process controllers and indicators

• Graphic recorders

• Stand alone or network solutions

• SCADA & data acquisition packages

• Small/large frame paper recorders

• Complete system solutions

• 0ºC to 3000ºC

• Adjustable emissivity

• Datalogging function

• Fixed or portable

• UKAS calibration

TEM

PER

ATU

RE

+43 1 706 43 000 95

Page 94: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

TEMPERATURE

Founded in the early 1900’s by HarryBrearley, the inventor of Stainless Steel,the business is now the No 1 supplier tothe UK Steel and Glass industries. Overthe years the business has continued todevelop its products and services tosatisfy the wider industry requirementsand now has an unrivalled capability.

Under the Brearley brand RM&C are thelargest manufacturer of industrialthermocouples and temperatureprobes in the UK. With a wealth ofexperience our technical help desk canprovide solutions through custom or

standard designs and provide a fullrange of accessories and fast trackdelivery for urgent requirements.

Products range from industrialthermocouple types, mineral insulatedand rare metal thermocouples andassemblies, to Pt100/RTD and non-contact pyrometry covering the range -0°C to 3000°C. Additionally we supply,configure, install and commissionprocess controllers, indicators, chartrecorders and dataloggers. We cansatisfy all your temperaturemeasurement requirements.

• Steel processing

• Glass and ceramic

• Food procesing

• Heat treatment

• Oil and gas pipelines

• Brewing

• Injection moulding

• Custom designs for rubber,plastics, food and hospital use

• Aerospace*

Applications

* RM&C are able to manufacturethermocouples to the requirements ofAMS2750. Our UKAS laboratory can alsocalibrate your instrumentation to therequirements of AMS2750.

TEMP

ERA

TUR

E

www.mess-regeltechnik.at96

Page 95: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

TEMPERATURE

Complete Range of Temperature Sensors

• Temperature range -200°C to 1800°C

• Mineral insulated - types N, K, J, E, T

• Rare metal - types R, S, B

• Resistance thermometers - 1/10 DIN, class A, class B, 2/3/4 wire - single or duplex

• Complete range of flexible thermocouples

• Wide range of bare wire thermocouples

• Wide choice of sheath materials

In addition RM&C stock an extensive range of cables, plugs and sockets.

TEM

PER

ATU

RE

+43 1 706 43 000 97

Page 96: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

TEMPERATURE

Eurotron

RM&C Instrumentation An official Eurotherm technical partner

The MicroCal 20 Series documenting process calibrators are a rugged hand tool forcalibration, maintenance and trouble shooting of virtually all control processinstrumentation.

• Calibrate temperature, pressure, voltage, frequency and resistance

• Dual channel display for simultaneous measure/source

• Measure and source 14 types of thermocouple and 10 RTDs

• 24 Vdc loop power supply (12 Vdc for IS)

• Connection for internal and external presssure module up to 700 bar

• Pressure switch test and leak test• Rechargeable battery and charger• Hold, zero, scale, min/max/avg, tare and flow

The IS versions are certified to ATEX II 1 G EEx ia II C T4,and are suitable for use in hazardous areas.

TEMP

ERA

TUR

E

www.mess-regeltechnik.at98

• Other products:

• Solid State Relays

• Power Controllers

• Thyristors

• Recorders(Paper & Paperless)

• Indicators

• Alarm Units

• Controllers

• Programmers

Page 97: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

TEMPERATURE

The compact infrared thermometerfor industrial and clean areaapplications.

For use at all engineering levels.

• -30 to 500°C temperature range

• Comfortable pistol grip

• Easy to use (°C/°F selectable)

• Just a “click” to measure

• Immediate response

• Ultra sharp laser sighting

• Large backlight LCD display

• Preset adjustable emissivity

• Max., min. & diff. reading

• High and low alarm

• Tripod mounting

Brearley IR

• Only 0.75 kg

• 160 x 120 image

• Simple operation

• Large, clear display

• Multiple temperature measurements

• Lowest cost high definition imageron the market

• Stores up to 1000 images

• Temperature range -10ºC to +250ºC

• Fully Radiometric

The IRI 4010 is an innovative handheld thermal imager which offersoutstanding imaging and temperaturemeasurement performance togetherwith the traditional RM&C featuresof flexibility, ease of use and minimalcost.

Thermal Imaging Camera

TEM

PER

ATU

RE

+43 1 706 43 000 99

Page 98: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

SERVICE & CALIBRATION

RM&C Service & Calibration• UKAS accredited for 4 fields of expertise

Pressure - Temperature - Flow - Electrical

• Over 30 years experience

• Flexibility to meet your demands - on or off site

• Fast and efficient service, maintenanceand repair service

Laboratory Parameters• Temperature up to 2200°C

• Flow up to 2400 L/min

• Pressure up to 1200 bar

• Electrical up to 1000V and 200A

On-site Service• Cost-effective control solutions

• Calibration with our mobile team of UKAS accredited engineers

• Supported from 2 regional branches

• Fast and effective breakdown service

• Assistance in checking condition of existing equipment

SERV

ICE/C

ALIB

RA

TION

www.mess-regeltechnik.at100

Page 99: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

SERVICE & CALIBRATION

RM&C is approved to the highestinternationally recognised standards,including ISO9001:2000 and ISO17025.

UKAS accredited RM&C Laboratories providetraceability to international standards forpressure, electrical, flow and temperaturemeasurement.

CapabilitiesTemperatureThermocouples -196°C to 1600°CNon-contract thermometry -50°C to 2200°CLIG Thermometers -80°C to 300°CResistance Thermometers -196°C to 300°CFurnace/Ovens Amb to 1600°CAutoclave/Media Preps Working rangeEnvironmental Chambers Up to 300°CIndicators & Probes -196°C to 1600°C

PressurePneumatic Up to 25 barHydraulic Up to 1200 barBarometers 200 mbar to 2000 mbar

FlowGas 5cc - 650 L/minWater 0.1 L/min - 2400 L/min

ElectricalIndicators/Controllers 16th EditionChart Recorders/Dataloggers ClampmetersDigital Multimeters StopwatchesResistance Boxes Process CalibratorsOther Electrical

SER

VIC

E/C

ALI

BR

ATI

ON

+43 1 706 43 000 101

Page 100: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

PUMPS OVERVIEW

Specification

Product Codes

RM&C Pumps and Services

Features• Can run dry without damage • Self-priming• Dosing and metering - constant output• Low pulsation• Pressure range from 1 bar to 172 bar• Quiet smooth operation• Easy and quick to maintain• Compact• Energy - efficient (80-85%) Hydra-cell

Benefits• Plastic pumps for strong acids and caustics• Metal pumps for abrasion resistance, solvents

and hydrocarbons• Solid size up to 10mm• Port size to 1/4" to 3"• No mechanical seals • Wide variety of liquids handled (clean/dirty/viscous

hot/flammable/acidic/abrasive)

On-site Service• Cost-effective pump solutions• Fast and effective pump repairs• Selection of pumps and spares held in stock• Fast and effective breakdown service

PU

MP

S

www.mess-regeltechnik.at102

Page 101: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

PUMPS OVERVIEW

Wanner Hydra-Cell Pumps

Size Pump capacity - pumps

1/4"3/8"1/2"3/4"1"1-1/2"2"3"

50 150 250 10L/min

Yamada Pumps Yamada DrumPumps

2010 100 800500 100 2005020 150

Pump capacity - drum pumps

Series 2000 Utility Pumps

Models L/min CodeG-20 Up to 3.8 G21XDBTHHEMGG-03 Up to 11.3 G03XKBTHHECAG-10 Up to 30.3 G10XKCTHFEYAG-15/17 Up to 56 G15XDBTHFEYAG-25 Up to 75.7 G25XKCTHFEYAG-35 Up to 140 G35XKCTHFEYA

Model Impeller Motor Max Max Max CodeFlow Head SolidL/min (m) (mm)

2051 Neoprene 230V 6 30 2 F481025442053 Nitrile 230V 6 22 2 F481025452003 Nitrile 230V 30 15 6 F481025412021 Neoprene 230V 30 30 6 F481025422103 Nitrile 110V 30 15 6 F48102543

PU

MP

S

(Air driven)

(Air driven)

Please contact our Technical Sales Team to discuss your application

+43 1 706 43 000 103

Page 102: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

SYSTEMS OVERVIEW

RM&C Systems • Nuclear sampling and monitoring specialists

• Bespoke equipment

• Turnkey projects

• Process measurement & control

• Solutions provider

Markets• Nuclear / Defence

• Energy / Utilities

• Chemical / Petro-Chem

• Food & Beverage

• Medical

• Others

Capabilities• Project Management

• Systems design

• Surveying through to commissioning

• Radiologically classified staff

• Security cleared staff

• UK Coverage from 2 branchesSY

STEMS

www.mess-regeltechnik.at104

Page 103: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

SYSTEMS OVERVIEW

Electrical & InstrumentationCabinets

ContinuousEmissionMonitoringSystems

Duct FlowMeasurement& IsokineticSampling

SYST

EMS

+43 1 706 43 000 105

Page 104: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

INST

RU

MEN

TATI

ON

RM&C INSTRUMENTATION

+43 1 706 43 000 107

SPECIFY

MA

NU

FAC

TU

RE

CALIBRATE INSTALL

&S

UP

PLY

REPLACE

MA

INT

AIN

Manufactured in the UK

Page 105: Flow • Pressure - LICO GmbH, Die ... Flowbits 2010_LICOa.pdf · SGUV Shunt Orifice Flowmeter 24 LPCB Fire Sprinkler Flowmeter 25 ... Switches Pre-Set Flow Switch 58 Adjustable Liquid

• Manufacture and supply offlow, pressure, temperature and level instrumentation

• Calibration and repair service either in our labs or on-site

www.mess-regeltechnik.at 2007/08

LICO Electronics GmbH Klederinger Str. 31

A-2320 Kledering, Austria [email protected] www.lico.at Tel. +43 1 706 43 00