This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved. Flow-control Devices for Side-pocket Mandrels API Specification 19G2 Second Edition, XXXXX 201X Effective Date: XXXXXX 201X The changes are focused around the design validation process after the question from a vendor relating to erosion testing was brought forward. This prompted a more thorough review of the design validation requirements and identified 13 changes that are highlighted by comments. There are also a few editorial improvements that are highlighted. Comments on the revised sections will be reviewed and resolved. Comments on any other portions will be considered for a future addendum or edition.

Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

Flow-control Devices for Side-pocket Mandrels API Specification 19G2

Second Edition, XXXXX 201X

Effective Date: XXXXXX 201X

The changes are focused around the design validation process after the question from a vendor relating to erosion testing was brought forward. This prompted a more thorough review of the design validation requirements and identified 13 changes that are highlighted by comments. There are also a few editorial improvements that are highlighted.

Comments on the revised sections will be reviewed and resolved. Comments on any other portions will be considered for a future addendum or edition.

Page 2: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

Annex C (normative)

Validation and device functional testing overview

Design validation and device functional testing requirements

The following table summarizes the design validation and device functional testing requirements that shall be performed for each flow-control device group and type (see 6.1.1 for a definition of each flow-control device and type). There are several categories of tests, for example interface testing, insertion testing, probe or travel testing, etc. However, the open and close test is only pertinent for design validation testing and the separate open and close tests are only pertinent for device functional testing.

The specific requirements for each category of test are defined in one of the normative Annexes D through M. In Table C.1, the required specific processes for each grade are identified.

Page 3: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

Table C.1— Testing Requirements

Flow-control device group

and type (See 6.1.2)

Design validation test and/or device functional test A

nnex

Design validation and device functional test requirements for each flow-control device grade

V3

Bas

ic g

rade

V2

Inte

rmed

iate

gr

ade

V1

Hig

hest

gr

ade

V0

Seve

re

serv

ice

F3

Bas

ic g

rade

F2

Inte

rmed

iate

gr

ade

F1

Hig

hest

gr

ade

F0

Seve

re

serv

ice

I IPO Balanced IPO IPO w/ choke

Interface D D.2.1 D.2.1 D.2.2 D.2.2 N/A N/A N/A N/A

Insertion E E.2 E.2 E.2 E.2 N/A N/A N/A N/A

Probe or travel F F.2 F.2 F.2 F.2 N/A F. 6.2 F.6.3 F.6.3

Load rate F F.3 F.3 F.3 F.3 N/A F.7.2 F.7.3 F.7.3

Flow G N/A G.2.2 G.2.3 G.2.3 N/A N/A N/A N/A

Back-check H H.2.2 H.2.3 H.2.4 H.2.5 H.3.1 H.3.1 H.3.2 H.3.3

Open and close I I.1.2 I.1.2 I.1.2 I.1.2 I.2, I.2, I.3.1 I.2, I.3.1 I.2, I.3.1

Actuation life cycle J N/A N/A J.2.2 J.2.2 N/A N/A N/A N/A

Erosion K N/A K.2.23 K.2.23 K.2.34 N/A N/A N/A N/A

Shelf L L.2.1 L.2.1 L.2.1 L.2.1 L.3.2 L.3.2 L.3.2 L.3.2

Port/seat leakage rate M M.2.1 M.2.1 M.2.1 M.2.1 M.3.1 M.3.1 M.3.1 M.3.1

II PPO

Interface D D.2.1 D.2.1 D.2.2 N/A N/A N/A N/A N/A

Insertion E E.2 E.2 E.2 N/A N/A N/A N/A N/A

Probe or travel F F.2 F.2 F.2 N/A N/A F.6.2 F.6.3 N/A

Load rate F F.3 F.3 F.3 N/A N/A F.5.2 F.5.3 N/A

Flow G N/A G.2.2 G.2.3 N/A N/A N/A N/A N/A

Back-check H H.2.2 H.2.3 H.2.4 N/A H.3.1 H.3.1 H.3.2 N/A

Open and close I I.1.2 I.1.2 I.1.2 N/A I.2 I.2, I.3.2 I.2, I.3.3 N/A

Actuation life cycle J N/A N/A J.2.2 N/A N/A N/A N/A N/A

Erosion K N/A K.2.2 K.2.2 N/A N/A N/A N/A N/A

Shelf L L.2.1 L.2.1 L.2.1 N/A L.3.2 L.3.2 L.3.2 N/A

Port/seat leakage rate M M.2.1 M.2.1 M.2.1 N/A M.3.1 M.3.1 M.3.1 M/A

Page 4: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

Table C.1 (continued)

Flow-control device group and type

(See 6.1.2)

Design validation test and/or device functional test A

nnex

Design validation and device functional test requirements for

each flow-control device grade V3

B

asic

gra

de

V2

Inte

rmed

iate

gr

ade

V1

Hig

hest

gr

ade

V0

Sev

ere

serv

ice

F3

Bas

ic g

rade

F2

Inte

rmed

iate

gr

ade

F1

Hig

hest

gr

ade

F0 S

ever

e se

rvic

e

III Pilot

Interface D D.2.1 D.2.1 D.2.2 N/A N/A N/A N/A N/A

Insertion E E.2 E.2 E.2 N/A N/A N/A N/A N/A

Flow G N/A G.2.2 G.2.3 N/A N/A N/A N/A N/A

Back-check H H.2.2 H.2.3 H.2.4 N/A H.3.1 H.3.1 H.3.2 N/A

Open and close I I.1.2 I.1.2 I.1.2 N/A I.2 I.2, I.3.2

I.2, I.3.3 N/A

Actuation life cycle J N/A N/A J.2.2 N/A N/A N/A N/A N/A

Erosion K N/A K.2.2 K.2.2 N/A N/A N/A N/A N/A

Shelf L L.2.1 L.2.1 L.2.1 N/A L.3.2 L.3.2 L.3.2 N/A

Port/seat leakage rate M M.2.1 M.2.1 M.2.1 N/A M.3.1 M.3.1 M.3.1 M/A

IV

Orifice Nozzle venturi Shear orifice Dump/kill

Interface D D.2.1 D.2.1 D.2.2 D.2.2 N/A N/A N/A N/A

Insertion E N/A N/A E.2 E.2 N/A N/A N/A N/A

Flow G N/A G.2.2 G.2.3 G.2.3 N/A N/A N/A N/A

Back-check H H.2.2 H.2.3 H.2.4 H.2.4 H.3.1 H.3.1 H.3.2 H.3.3

Open and close I I.1.2 I.1.2 H.2.4 H.2.4 H.3.1 H.3.1 H.3.2 H.3.3

Erosion K N/A K.2.2 K.2.2 K.2.3 N/A N/A N/A N/A

Port/Seat leakage rate M - - - - M.3.1 M.3.1 M.3.1

V Dummy Interface D D.2.1 D.2.1 D.2.2 N/A N/A N/A N/A N/A

Page 5: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

Annex E (normative)

Insertion testing requirements

E.1 General

The insertion test requirements for the four design validation grades are indicated below. The test shall demonstrate that installation of a flow-control device into a side-pocket mandrel shall not significantly change the flow-control device’s set pressure or operating characteristics. The insertion test shall be conducted using the following methods, fixtures, and procedures.

E.2 Requirements for design validation

E.2.1 General

The insertion test requirements for design validation grades V3, V2, V1 and V0 are defined in E.2.2 to E.2.5.

E.2.2 Number of test specimens

This test shall be conducted on a minimum of seven flow-control devices of each design family. This is required to ensure that the activation pressure is maintained and applied to the design.

E.2.3 Test procedure

In this procedure, only steps e) through i) shall be followed for shear orifice and dump kill devices of class IV flow-control devices.

While the device is in the test fixture, validate that the device performs as required in accordance with its documented design parameters. The insertion test requirements for design validation grades V3, V2, V1, and V0 shall be as follows.

In this procedure, only steps d) through j) shall be followed for class IV shear orifice and dump kill devices.

a) Set the flow-control device at a minimum of 75 % of its maximum rated pressure at a reference temperature defined by the supplier/manufacturer.

b) Allow the flow-control device and test fixture to stabilize to ambient temperature.

c) Record the opening pressure, PvoT, and closing pressure, P vcT , of the flow-control device and the ambient temperature of the device and its test fixture.

d) Attach the flow-control device to the designated latch.

e) Prepare the test stand to perform this procedure. Such a test stand may be configured as illustrated by Figure E.1.

f) Attach the flow-control device and latch to the specific running tool, using the appropriate pin(s).

g) Attach the flow-control device, latch and running tool to the mechanical jars as necessary to perform the tests. An example of such a configuration is illustrated by Figure E.1.

Commented [WM1]: Design Validation comment 1: Deamed unnecessary and deleted

Page 6: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

h) Using the full jar stroke and free fall of the weight bar, drive the flow-control device into the pocket with a minimum of five wireline-activated blows. If the latch is not engaged in the “no-go” position, continue jarring until engaged.

i) Jar upwards to release the running tool from the latch, leaving the latch and the flow-control device in the test fixture.

j) Measure and record the PvoT and the ambient temperature with the flow-control device in the test fixture pocket.

- For class IV shear orifice and dump kill devices, PvoT is construed to be the ambient opening activation pressure.

k) Record the difference between the original PvoT and the PvoT after the insertion test. Insertion testing form 1 (Figure E.2) or insertion testing form 2 (Figure E.3) may be used to record these results. PvoT shall be translated to equivalent temperatures if different.

l) Evaluate the PvoT acceptance criteria, see E.2.4 a. If successful, proceed to step o).

m) Measure and record PvcT and the ambient temperature with the flow-control device in the test fixture pocket.

n) Evaluate the PvcT acceptance criteria.

o) Remove the flow-control device from the tester.

Key

1 rope socket 2 gin pole 3 1.83 m (6 ft) section of 6.03 cm (2 3/8 in) OD tubing for guide for spang jars and weight bar 4 simulated pocket with test connections for checking FCD set pressure 5 tool string with

1.52 m (5 ft) of 38.1 mm (1 1/2 in) OD stem 50.8 cm (20 in) stroke of 38.1 mm (1 1/2 in) spang jar appropriate running tool

Figure E.1 — Typical vertical FCD insertion test stand

Page 7: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

E.2.4 Acceptance criteria

All seven flow-control devices shall satisfy the following criteria:

a) PvoT shall not change by more than 1 % of the original PvoT when corrected to the ambient temperature. For this test to be accepted, PvoT shall meet this criterion, or the PvcT criterion in step b) shall be met.

- For class IV shear orifice and dump kill devices only, PvoT as defined in E.2.3.j shall meet the acceptance criteria of I.5.

b) PvcT shall not change by more than 2.0 % of the design PvcT as corrected to the same ambient temperature.

c) If more than one device of the original seven test devices fails the test, an additional seven devices shall be selected and the entire test process shall be performed on the new devices. Device failures shall be documented and corrective actions recorded.

E.2.5 Documentation

The following additional specific documentation is required. Record the results of the insertion tests on insertion testing form 1 (Figure E.2) or insertion testing form 2 (Figure E.3), as appropriate.

Insertion testing form 1

FCD serial

number

Initial test data Final test data (FCD in fixture)

Change in PvoT

gauge kPa (psig)

Change in FCD temperature

°C (°F)

PvoT gauge kPa

(psig)

Ambient temperature °C

(°F)

PvoT gauge kPa (psig)

Ambient temperature °C

(°F)

Air FCD Fixture Air FCD Fixture

1

2

3

4

5

6

7

8

9

10

Figure E.2 —Example insertion testing form 1 for PvoT test results

Page 8: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

Insertion testing form 2

FCD serial

number

Initial test data Final test data (FCD in fixture)

Change in PvcT

gauge kPa (psig)

Change in FCD temperature

°C (°F)

PvcT gauge kPa

(psig)

Ambient temperature °C

(°F)

PvcT gauge kPa (psi)

Ambient temperature °C

(°F)

Air FCD Fixture Air FCD Fixture

1

2

3

4

5

6

7

8

9

10

Figure E.3 — Example insertion testing form 2 for PvcT test results

Page 9: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

Annex F (normative)

Probe and travel testing and load rate determination

F.1 General

This annex provides requirements for probe and travel testing, and load rate determination of flow-control devices.

F.2 Probe or travel test requirements for design validation

F.2.1 General

The probe or travel test requirements for design validation grades V3, V2, V1 and V0 are defined in this annex.

F.2.2 Number of test specimens

This test shall be conducted on a minimum of seven (7) flow-control devices of each design family.

F.2.3 Test procedure

The test procedure will determine the maximum effective stem travel (see F.10), the load rate (see F.9), and the maximum stem travel (see F.8).

F.2.4 Acceptance criteria

All seven flow-control devices shall meet the following criteria. The maximum effective stem travel distance of each device shall be large enough to provide a flow area between the stem/seat interface that is greater than the flow area of the port.

F.2.5 Documentation

Record the maximum effective travel distance of each device using the probe test data form 1 (see Figure F.3), or an equivalent.

F.3 Load rate determination requirements for design validation

F.3.1 General

The load rate requirements for design validation grades V3, V2, V1 and V0 are defined below.

F.3.2 Number of test specimens

This test shall be conducted on a minimum of seven flow-control devices of each design family.

F.3.3 Test procedure

Determine the load rate and establish the maximum effective stem travel of each device. The test procedure shall be as defined in F.8. The test data shall be analyzed using the procedures in F.9.

Page 10: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

F.3.4 Acceptance criteria

All seven flow-control devices shall meet the following criteria. The load rate of each flow-control device shall be within ±10 % of the average of the seven load rates.

F.3.5 Documentation

Documentation of the results of the probe tests is required. Record the load rate of each device using the probe test data form 1 (see Figure F.3) or an equivalent.

F.4 Introduction to flow-control device probe and travel testing

The purpose of this test is to determine the relative stiffness of the responsive element assembly of a flow-control device and to determine the maximum effective travel of the stem. When gas pressure is applied to the test system, it shall act on the full area of the flow-control device bellows to lift the stem off the seat. When this pressure is increased, the stem lifts further from the seat. By using the flow-control device probe tester (Figure F.1 is an example), measurement of the stem travel versus pressure can be determined and the results tabulated and plotted.

When the pressure is plotted as the ordinate (vertical axis) and the stem travel as the abscissa (horizontal axis), a relatively straight line is generated for the effective stem travel. The slope of this line is an indication of the stiffness of the flow-control device. The numerical value of the slope is called the “bellows assembly load rate”, Blr, and is measured in kilopascals per centimeter (pounds per square inch per inch). In this context, the bellows assembly includes the bellows and the flow-control device mechanism that applies a load to hold the flow-control device stem on the seat.

NOTE The higher the load rate, the stiffer the responsive element assembly of the flow-control device.

If the above test is conducted with the same flow-control device, except that the opening pressure (dome charge or spring setting) is varied, then the effect of the dome charge pressure or spring setting on the bellows assembly load rate may be compared for the same type of flow-control device when set for different opening pressures.

The maximum effective stem travel and bellows assembly load rate are values used to compare different types of flow-control devices, when evaluating the same flow-control device under different load conditions or when designing the installation.

F.5 Equipment required for probe and travel testing

F.5.1 Test stand

The test stand shall have a means for controlling and measuring the pressure applied to the flow-control device sleeve. The apparatus shown in Figure F.1 is an example of a suitable test stand for the probe test. The apparatus shown in Figure F.2 is an alternative device using a linear variable differential transducer (LVDT) for measuring the position.

Page 11: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

Key

1 flow-control device 5 insulated bushing 2 tester 6 micrometer 3 pressure gauge 7 ohmmeter 4 tester gas 8 bleed

Figure F.1 — Typical flow-control device probe tester

Page 12: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

Key

1 flow-control device 4 tester gas 2 tester 5 LVDT 3 pressure gauge 6 bleed

Figure F.2 — Typical flow-control device probe tester with LVDT

F.5.2 Flow-control device sleeve

The sleeve shall communicate pressure from a source to the flow-control device without perceptible leaks. The source pressure shall be communicated both above and below the flow-control device seat when the flow-control device is closed. The test device shall have the ability to apply the test pressure across the full area of the bellows of the flow-control device.

F.5.3 Flow-control device position measurement

For the manual method, the position measurement device shown in Figure F.1 is a micrometer designed to accurately measure the stem travel. The measurement method shall be capable of determining the stem position within ± 0.127 mm (0.005 in).

For the automatic method, the position measurement device shown in Figure F.2 is an LVDT designed to accurately measure the stem travel. Only when inlet and outlet test pressures are within 68.9 kPa (10 psig) of each other can stem travel measurements be used for analysis.

F.6 Probe or travel test requirements for device functional testing

F.6.1 Requirements for device functional testing, grade F3

There are no probe or travel test requirements for device functional testing grade F3.

Page 13: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

F.6.2 Requirements for device functional testing, grade F2

F.6.2.1 General

The probe or travel test requirements for device functional testing grade F2 shall be as defined below.

F.6.2.2 Number of test specimens

This test shall be performed on a minimum of 5 % of any job lot or three flow-control devices, whichever is greater. If a job lot consists of three or fewer devices, they shall all be tested.

F.6.2.3 Test procedure

The test procedure to determine maximum effective stem travel (see F.10) first requires the probe test to be performed (see F.8) and then the load rate shall be determined (see F.9). The results of the probe test and the load rate determination are then used to determine the maximum effective travel (see F.10).

F.6.2.4 Acceptance criteria

The maximum effective travel shall be ± 10 % of the maximum effective travel established during the design validation test procedure.

F.6.2.5 Documentation

Documentation of the results, raw data and calculations of the probe or stem travel tests is required. Record the maximum effective stem travel.

F.6.3 Requirements for device functional testing, grade F1 and F0

The probe or travel test requirements for device functional testing grade F1 and F0 shall be the same as for grade F2 except that the tests shall be performed on 100 % of the flow-control devices in any job lot.

F.7 Load rate determination requirements for device functional testing

F.7.1 Requirements for device functional testing, grade F3

There are no load rate test requirements for device functional testing grade F3.

F.7.2 Requirements for device functional testing, grade F2

F.7.2.1 General

The load rate test requirements for device functional testing grade F2 shall be as defined below.

F.7.2.2 Number of test specimens

This test shall be performed on a minimum of 5 % of any job lot or three flow-control devices, whichever is greater. If a job lot consists of three or fewer devices, they shall all be tested.

F.7.2.3 Test procedure

The flow-control device shall be tested in accordance with the procedure defined in F.8. The load rate shall be calculated in accordance with the procedure defined in F.9. The maximum stem travel is defined in F.10.

Page 14: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

F.7.2.4 Acceptance criteria

The calculated load rate of each device shall be ± 10 % of the average load rate established. In the event that one of the FCDs is outside of the calculated load range, another group shall be tested.

F.7.2.5 Documentation

Record the load rate.

F.7.3 Requirements for device functional testing, grade F1 and F0

The probe or travel test requirements for device functional testing grade F1 and F0 shall be the same as for grade F2 except that the tests shall be performed on 100 % of the flow-control devices in any job lot.

F.8 Probe test procedure

F.8.1 Requirements

The supplier/manufacturer shall prepare a written test procedure for conducting the probe test. The items in F.8.2 to F.8.4 shall, as a minimum, be addressed in the procedure.

F.8.2 Prepare the flow-control device for testing

Nitrogen-charged flow-control devices and combination FCDflow-control devices (spring-loaded and nitrogen-charged) shall be validation probe tested at opening pressures, PvoT, of 5515 gauge kPa (800 psig), 8274 gauge kPa (1200 psig) and at the supplier/manufacturer’s maximum recommended pressure rating. Nitrogen-charged and combination flow-control devicesFCDs that fall outside of this range shall be tested at the manufacturer/supplier’s minimum and maximum recommended troP as well as half the value between the minimum and maximum recommended troP .

Spring-loaded flow-control devices shall be probe tested at the supplier/manufacturer’s maximum recommended opening pressure, Pvo, or closing pressure, Pvc.

All FCD functional testing shall be performed with a single opening pressure used during validation. The selection of the opening pressure used during the functional testing is to be defined by the supplier/manufacturer or the user/purchaser at the time of purchase.

F.8.3 Assemble test equipment

Assemble the test equipment in accordance with the written test procedures.

F.8.4 Perform probe test

Steps for conducting the probe test with a test fixture as shown in Figure F.1. If an automated test procedure is used in accordance with Figure F.2, or a similar method, this shall be defined in the written test procedure and each of the items defined below shall be addressed. All applied pressures, temperatures and measurements shall be recorded in the test report.

The test procedure is as follows.

a) Increase the pressure slowly to the test sleeve until the position measurement device indicates the stem is no longer touching the seat. This is the pressure at which the flow-control device just opens when test pressure is applied across the full area of the bellows, PvcT.

b) Adjust the position measurement device to determine the new stem position. Advance the probe with the micrometer barrel until it contacts the tip of the flow-control device stem. This is noted by a significant decrease in the ohmmeter resistance reading.

Commented [WM2]: Editorial

Commented [WM3]: Design Validation comment 2: This eliminates the unnecessary probe testing of each production FCD at three different dome charges for product functional testing.

Page 15: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

c) Record the pressure and the stem position using the probe test data form 1 (see Figure F.3) or an equivalent electronic data storage method.

d) Repeat steps a) and b) using the same pressure increment. These pressure increments shall yield at least five recordings within the range of the maximum effective stem travel.

If the test pressure increases to a value greater than the target pressure, do not decrease the pressure; continue with the test using the pressure recorded and measured at this point.

e) Decrease the pressure to the test sleeve in increments such as: 69 kPa (10 psi), 103 kPa (15 psi), 138 kPa (20 psi) or 172 kPa (25 psi), or of increments of the operational pressure range which include five approximately equally spaced pressure readings over the range of stem travel.

Before decreasing the pressure, retract the probe rod by reversing the measurement tool to prevent stem tip contact during pressure decrease. If the test pressure drops to a value less than the target pressure, do not increase the pressure; continue with the test using the pressure recorded and measure at this point.

f) Adjust the stem position measurement device to determine the new stem position.

Advance the probe with the micrometer barrel until it contacts the tip of the flow-control device stem. This can be noted by a significant decrease in the ohmmeter resistance reading.

g) Record the pressure and the stem position using the probe test data form 1 (see Figure F.3).

Repeat e) through g) using the same pressure increments until the flow-control device stem is back on its seat [initial micrometer reading ± 0.127 mm (0.005 in)]. At least five stem positions shall be recorded within the range of the maximum effective stem travel.

If the test pressure drops to a value less than the target pressure, do not increase the pressure; continue with the test using the pressure recorded and measure at this point.

Probe test data form 1

1 Attach assembly drawing of probe test apparatus

2 Type of pressure measurement device

— Accuracy

3

Flow-control device designation

Supplier/manufacturer’s part number of flow-control device

Attach a dated assembly drawing of flow-control device

4 Test data: flow-control device set pressure, gauge kPa (psig)

— Pvo or Pvc

5 Attach graph showing test pressures, stem positions, best-fit straight line and maximum effective stem travel

6 Bellows assembly load rate, Blr, kPa/cm (psi/in)

7 Date test was performed

8 Person who performed test

Test No. Test pressure

gauge kPa (psig) Actual stem measurement

1

2

3

Page 16: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Figure F.3 — Probe test data form 1

F.9 Determine flow-control device load rate

F.9.1 Plot the data

Plot the data with the pressure readings on the vertical axis and the stem position readings on the horizontal axis as shown in Figure F.4.

Note, on Figure F.4, that there are two distinct regions of the plot where the slopes are different. The region identified as slope A is the effective usable travel range of the flow-control device. The region identified as slope B is the travel range where the bellows have met a substantial resistance to travel and represents travel that is not normally usable. This additional resistance to travel can be the result of many different factors but is usually the result of bellows stacking or reaching a bellows stop.

The region of slope A shall extend from zero stem travel to the point where the slope of the load rate data turns sharply upward. This point shall be visually determined. Draw the best-fit straight line to the data of the region corresponding to slope A. See Figure F.5 for an example.

Page 17: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

▄ data points

Key

X stem travel, millimeters (inches) Y test pressure, gauge kilopascals (pounds per square inch gauge)

1 region of slope A 2 increasing test pressure 3 decreasing test pressure 4 point at which the slope changes 5 region of slope B

Figure F.4 — Example plot of stem travel data

0 1.27 2.54 3.81 5.08 6.35 7.62 (0) (0.05) (0.1) (0.15) (0.2) (0.25) (0.3)

8 140 (1 180) 8 000

(1 160) 7 860

(1 140) 7 720

(1 120) 7 580

(1 100) 7 450

(1 080) 7 300

(1 060) 7 170

(1 040) 7 030

(1 020) 6 890

(1 000)

Page 18: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

▄ data points

Key

X stem travel, millimeters (inches) Y test pressure, gauge kilopascals (pounds per square inch gauge)

1 point where y = P1 2 point where y = P2 3 region of slope A 4 best-fit straight line of data in region of slope A 5 visually determined point at which slope changes 6 maximum effective stem travel, dLST

NOTE Load rate, Blr, is equal to (P1 − P2)/dLST.

Figure F.5 — Example chart to determine bellows load rate

F.9.2 Calculate the slope

NOTE See Figure F.5.

Calculate the slope, mbf, of this best-fit straight line as given in Equation (F.1):

( )1 2bf d

P Pm

x−

= (F.1)

where

P1 is the upstream gauge pressure of test section, expressed in gauge kilopascals (pounds per square inch);

8 140 (1 180)

8 000 (1 160)

7 860 (1 140)

7 720 (1 120)

7 580 (1 100)

7 450 (1 080)

7 300 (1 060)

7 170 (1 040)

7 030 (1 020)

6 890 (1 000) 0 1.27 2.54 3.81 5.08 6.35 7.62

(0) (0.05) (0.1) (0.15) (0.2) (0.25) (0.3)

Page 19: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

P2 is the downstream gauge pressure of test section, expressed in gauge kilopascals (pounds per square inch).

The slope of this line is the bellows assembly load rate, Blr, of the flow-control device.

The bellows assembly load rate, Blr, documentation shall include a graph showing all the data points, the best-fit straight line and the Blr calculation.

F.10 Determine maximum effective stem travel

The maximum effective stem travel is the greatest travel obtainable within the region of slope A as shown in Figure F.5.

NOTE See F.9 for a detailed explanation of the load-rate and maximum effective stem travel calculation.

F.11 Probe test documentation

The following minimum data shall be documented. The probe test data form 1 (see Figure F.3) is a recommended method for recording these data.

a) assembly drawing of the probe test equipment;

b) type and accuracy of the pressure gauge or transducer;

c) type of tested flow-control device, supplier/manufacturer’s flow-control device designation and part number and dated assembly drawing of flow-control device;

d) test data including

1) flow-control device set pressure,

2) test pressures,

3) stem positions,

e) graph showing

1) tested pressures and stem positions,

2) best-fit straight line,

f) bellows assembly load rate, Blr;

g) maximum effective stem travel;

h) date test performed;

i) person in charge of the test;

j) test summary and approval by qualified person.

Page 20: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

Annex H (normative)

Back-check testing requirements

H.1 General

The following tests are defined for reverse flow or back-check subassemblies in flow-control devices. These devices are designed and intended to prevent reverse flow through a flow-control device. The requirements defined herein shall conform to the user/purchaser’s selected design validation and functional testing grades.

Included in this annex are the requirements for design validation testing grades V3, V2, V1, and V0. These reverse flow or back-check samples may be tested as a subassembly. The design validation for V1 requires the testing of the same samples as have passed the requirements of V2. The design validation for V2 requires the testing of the same samples as have passed the requirements of V3.

Validation testing for V0 requires one reverse flow or back-check subassembly to be tested in the order shown and conforming to the V0 acceptance criteria without redress or rebuild. The back-check design provided for V0 testing shall also meet the requirements of V1 in order to be validated as V0. The reverse flow or back-check subassembly need not be the same one used during the V1 validation process. Non-conformance to any of the criteria is a cause to stop the testing.

Design validation grades V1, V2 and V3 are designed for standard service applications each succeeding test further qualifies the back-check as a reverse-flow device. Design validation grade V0 (I.2.4) is for severe service applications which may be intended or utilized as a part of a safety system, where a tight shut-off pressure safety seal is required. Testing for V2, V1, and V0 shall be performed in the order shown.

Also included in this annex are functional tests requirements for F3, F2, F1, and F0. Functional testing requirements are applied to each back-check subassembly manufactured. The testing for F0 is limited to devices which have completed design validation V0. Each test procedure, parameters, fluids and the results shall be documented and the final results approved by a qualified person.

All design documentation shall conform to 7.2.2 & 7.2.5.

H.2 Requirements for design validation

H.2.1 Number of test specimens

The requirements for test specimens are as follows:

a) V3, V2, and V1 design validation tests shall be conducted on a minimum of seven (7) flow-control samples of each design family. If more than one (1) sample of the original seven test devices fails the test, an additional seven samples shall be selected and the entire test process shall be performed on the new samples, in conformance with 6.5.1.

b) V1 design validation back-check erosion test shall be conducted on one of the seven selected flow-control sample.

c) V0 design validation shall be conducted on one (1) reverse flow or backcheck subassembly sample conforming to V1, F1, and QL1 requirements of this specification. See para 6.5.1. One sample is to undergo the complete V0 design validation successfully without disassembly and/or redress.

Page 21: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

H.2.2 Requirements for design validation, grade V3

H.2.2.1 General

The test requirements for design validation, grade V3, shall be as defined in H.2.2.2 to H.2.2.3.

H.2.2.2 Test procedure

The following tests shall be successfully performed in the order listed to satisfy the design V3 validation requirements:

a) A mechanical function test in accordance with Clause H.4;

b) A backflow integrity test at maximum rated pressure in accordance with Clause H.5.

H.2.2.3 Documentation

Record the results of each mechanical function testing and the results of each backflow integrity test.

H.2.3 Requirements for design validation, grade V2

H.2.3.1 General

The test requirements for design validation, grade V2, shall be as defined in H.2.3.2 to H.2.3.3.

H.2.3.2 Test procedure

The following tests shall be successfully performed in the order listed to satisfy the V2 design validation requirements:

a) Meet all test requirements for design validation, grade V3;

b) A backflow integrity test using gas in accordance with Clause H.6;

c) TheFor hydraulically activated back-check FCDs, conduct the minimum liquid flow rate and differential-pressure activation test in accordance with Clause H.7;

d) For spring-loaded back-check FCDs, determine the pressure differential required to open the back-check valve in accordance with Clause H.8;

e) For both flow-activated and spring-loaded check valves, perform the mechanical function test as defined in Clause H.4 to ensure that the check dart does not stick to the check-valve seat.

H.2.3.3 Documentation

Record the results for each:

a) Gas backflow integrity test results;

b) For hydraulically activated back-check FCDs, minimum liquid flow rate and differential-pressure activation test;

c) test of For spring-loaded back-check FCDs, pressure differential required to open spring-loaded back-check valves;

d) Results of the repetition of mechanical function test.

NOTE See 7.2 for design validation documentation requirements.

Page 22: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

H.2.4 Requirements for design validation, grade V1

H.2.4.1 General

The test requirements for design validation, grade V1, shall be as defined in H.2.4.2 to H.2.4.3.

H.2.4.2 Test procedure

The following tests shall be successfully performed in the order listed to satisfy the V1 design validation requirement:

a) Meet all test requirements for design validation, grade V2;

b) Repeat the backflow integrity tests predefined in H.5 at the maximum rated temperature +5%/-0% of the flow-control device. The test shall be conducted at a low differential pressure of 689 kPa [(100±5)psi];

c) Conduct the minimum liquid flow rate anddefined in Clause H.7 or the differential pressure activation test defined in Clause H.78 at the supplier/manufacturer’s rated pressure +5%/-0%;

d) Conduct a back-check erosion test as defined in Clause K.3.2 on one flow-control device. See H.2.1 b.

H.2.4.3 Documentation

Record the results of each:

- backflow integrity test; - minimum liquid flow rate andor differential-pressure activation test; - back-check erosion test.

H.2.5 Requirements for design validation, grade V0

H.2.5.1 General

The test requirements for design validation V0, shall be as defined in H.2.5.2 to H.2.5.3.

H.2.5.2 Testing procedure

The following tests shall be successfully performed in the order listed to satisfy the V0 design validation requirement.

a) Initial Function Test:

1) mechanicalMechanical function test in accordance with Clause H.4;

2) liquidLiquid backflow integrity test at ambient temperature in accordance with Clause H.5.4;

3) liquidLiquid backflow integrity test at elevated temperature in accordance with Clause H.5.5;

4) gasGas backflow integrity test at ambient temperature in accordance with Clause H.5.7;

5) gasGas backflow integrity test at elevated temperature in accordance with Clause H.5.8;

6) minimumMinimum liquid flow rate test in accordance with Clause H.7;

7) pressurePressure differential test in accordance with Clause H.8.

Commented [WM4]: Design Validation comment 3: Add clarity to requirments

Commented [WM5]: Design Validation comment 4: Depending on check-dart closure method, one or the other required, not both.

Commented [WM6]: Editorial changes

Page 23: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

b) Unloading Test

1) erosionErosion test in accordance with Clause K.3;

2) liquidLiquid backflow integrity test at ambient temperature in accordance with Clause H.5.4;

3) gasGas backflow integrity test at ambient temperature in accordance with Clause H.5.7;

4) minimumMinimum liquid flow rate test in accordance with Clause H.7.

c) Gas Flow Test

1) Full scale gas flow test in accordance with Clause H.9

d) Final Functional Test

1) Repeat Initial Functional Test sequence (H.2.5.2.a)

H.2.5.3 Documentation

Record the results of each. All flow rates, pressures, and temperatures are to be continually monitored and recorded and observations duly noted.

H.3 Requirements for device functional testing

The requirements of F0 shall be performed only on back-check subassembly designs that have been validated to V0.

H.3.1 Requirements for device functional testing, grade F3 and F2

H.3.1.1 General

The test requirements for device functional testing, grade F2 and F3, shall be performed as defined in H.3.1.2 to H.3.1.3. The test shall be performed on 100 % of any job lot.

The following tests shall be performed:

a) A mechanical function test as defined in Clause H.4 shall be performed;

b) A nitrogen gas (N2) back-check leak test in accordance with Clause H.6 shall be conducted.

H.3.1.2 Documentation

The following items are required as documentation:

a) recorded results of each test;

b) description of the mechanical function test and N2 back-check leak test.

H.3.2 Requirements for device functional testing, grade F1

H.3.2.1 General

The test requirements for device functional testing, grade F1, shall be as defined in H.3.2.2 to H.3.2.3. The test shall be performed on 100 % of any job lot.

Commented [WM7]: Editorial changes.

Page 24: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

H.3.2.2 Test procedure

The following test shall be performed:

a) Meet all device functional testing test requirements for device functional testing, grade F2;

b) The minimum activation rates/pressures shall be determined for hydraulically activated back-check systems as defined in H.7, or the minimum activation pressure for normally closed back-checks as defined in H.8.

H.3.2.3 Documentation

Record the minimum and maximum back-check activation rates and pressures required by the test procedures.

H.3.3 Requirements for device functional testing grade F0

H.3.3.1 General

The test requirements for device functional testing, grade F0, shall be as defined in H.3.3.2 to H.3.3.3. The test shall be performed on 100 % of any job lot.

H.3.3.2 Test procedure

The following test shall be performed in the order listed to satisfy the grade F0 functional test requirement:

a) mechanical function test in accordance with Clause H.4;

b) liquid backflow integrity test at ambient temperature in accordance with Clause H.5.4;

c) gas backflow integrity test at ambient temperature in accordance with Clause H.5.7;

d) The minimum activation rates/pressures shall be determined for hydraulically activated back-check systems as defined in H.7, or the minimum activation pressure for normally closed back-checks as defined in H.8.

H.3.3.3 Documentation

Record the results of each of the test procedures.

H.4 Mechanical function test

H.4.1 General

Two types of back-check subassemblies are commonly used in flow-control devices: normally closed and hydraulically activated designs. The mechanical test for each type is detailed in H.4.2 and H.4.3, respectively.

H.4.2 Normally closed back-check subassemblies

H.4.2.1 General

This type of back-check valve is normally closed.

H.4.2.2 Test procedure

The following shall be performed to satisfy the mechanical function test requirements for normally closed back-check subassemblies:

Page 25: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

a) The flow-control device shall be tested in a test fixture similar to the fixture used for open and close pressure tests (see Figure I.1);

b) The hydraulic pressure acting on the check system shall be increased to the activation pressure of the flow-control device;

c) The flow of the hydraulic test fluid shall be evident at the outlet of the flow-control device;

d) The pressure acting on the check system shall be reduced to atmospheric and a visual inspection of the check dart shall indicate its seating.

H.4.2.3 Acceptance criteria

For acceptance of the mechanical function test, the check dart shall move freely from the open to the closed position and from the closed to the open position without human intervention. If any device fails to move as required, the test fails.

H.4.3 Hydraulically activated back-check subassemblies

H.4.3.1 General

This type of back-check valve is normally open and requires reverse flow for activation.

H.4.3.2 Test procedure

The following shall be performed to satisfy the mechanical function test requirements for hydraulically activated darts:

a) Hold the flow-control device in the normal manner in which it is positioned in the side-pocket mandrel;

b) Visually inspect the outlet of the flow-control device and verify that the check dart is located in its lowermost position.

Invert the flow-control device and visually inspect that the check dart has properly mated with the sealing surface.

H.4.3.3 Acceptance criteria

For acceptance of the mechanical function test, the check dart shall move freely from the open to the closed position and from the closed to the open position without human intervention. If any device fails to move as required, the test fails.

For acceptance of the repeat mechanical function test required in H.2.3.2, the check dart shall move freely from the open to the closed position and from the closed to the open position without human intervention. If one or more devices fail to move as required, the test fails.

H.5 Backflow integrity test

H.5.1 General

The backflow integrity test ensures that the back-check valve will act as a reverse flow check when subjected to hydraulic pressures applied from the reverse direction of normal flow.

H.5.2 V3, V2, and V1 liquid backflow integrity test procedure

The following shall be performed to satisfy the backflow integrity test requirements:

Page 26: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

a) Apply hydraulic pressure to the reverse-flow or back-check valve of the flow-control device, in the opposite direction to normal flow through the device;

b) Test to the supplier/manufacturer’s maximum rated pressure +10% or -0%;

c) Hold the pressure for a minimum of 1 minute;

d) For flow-activated reverse-flow check valves, ensure that the reverse-flow check does not stick to the primary/secondary seal after completion of the backflow integrity test.

H.5.3 V3, V2, and V1 liquid backflow integrity test acceptance criteria

Each test result shall meet the requirements specified in the supplier/manufacturer’s written procedures. As a minimum, the device shall exhibit no pressure drop over the 1-minute hold period.

H.5.4 V0 Liquid backflow integrity test at ambient temperature

The following shall be performed to satisfy the backflow integrity test requirements:

a) Use water at ambient temperature conditions and apply hydraulic pressure to the back-check valve of the flow-control device, in the direction opposite to normal flow through the device;

b) Test to a differential pressure of 689 kPa (100 psi) ±10%. Let the system stabilize and maintain a minimum hold period of 10 minutes;

c) For hydraulically activated back-check valves, ensure that the dart does not stick to the primary and/or secondary seal after completion of the backflow integrity test;

d) Repeat step from a) to c) two times;

e) Repeat step from a) to d) and test to 100% of maximum rated pressure, +10% /-0%.

H.5.5 V0 Liquid backflow integrity test at elevated temperature

Repeat liquid backflow integrity test at or above maximum rated working temperature conditions.

Note: the use of heat transfer fluid is acceptable for liquid testing at elevated temperatures.

H.5.6 V0 Liquid backflow acceptance criteria

For acceptance of the backflow integrity test, no more than a 1% reduction in the differential pressure over the hold period after sufficient time has been allowed for stabilization.

For the 689 kPa (100 psi) differential pressure test a pressure drop up to 21 kPa (3 psi) over the hold period is accepted.

H.5.7 V0 Gas backflow integrity test at ambient temperature

The following shall be performed to satisfy the backflow integrity test requirements:

a) Apply air, nitrogen, helium, or another compressed gas at ambient temperature conditions to the back-check valve of the flow-control device, in the direction opposite to normal flow through the device;

Note: For safety considerations non-flammable gases are recommended for all testing;

Page 27: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

b) Test to a differential pressure of 689 kPa (100 psi), +/- 10%. Let the system stabilize and maintain a minimum hold period of 10 minutes;

c) For flow activated reverse flow check valves, ensure that the reverse flow check does not stick to the primary and/or secondary seal after completion of the backflow integrity test;

d) Repeat step a) to c) two times;

e) For validation testing, repeat steps a) to d) and test to 75% of maximum rated pressure, +10% /-0%;

f) For functional testing, repeat steps a) to d) and test to 25% of maximum rated pressure, +10% /-0%.

H.5.8 V0 Gas backflow integrity test at elevated temperature

Repeat gas backflow integrity test (H.5.7) using maximum rated working temperature conditions.

H.5.9 V0 Gas backflow integrity test acceptance criteria

For acceptance of the backflow integrity test, no more than 20 cm3 (1.22 in3) leakage over the hold period after sufficient time has been allowed for stabilization. The bubble rate shall not increase during the hold period.

H.6 Gas test

H.6.1 Test procedure

The following shall be performed to satisfy the gas test requirements:

a) Apply air, nitrogen, helium or another compressed gas at (689 ± 34.5) kPa [(100 ± 10) psi] differential pressure to the reverse-flow or back-check valve of the flow-control device, in the opposite direction to normal flow through the device;

Note: For safety considerations non-flammable gases are recommended for all testing.

b) Test in accordance with the supplier/manufacturer’s written specifications.

H.6.2 Acceptance criteria

a) For acceptance of the backflow integrity test using gas, each test result shall meet the test requirements specified in the supplier/manufacturer’s written test procedures;

b) The leak rate shall not exceed 1 SCMD (35 SCFD).

H.7 Minimum liquid rate for hydraulically activated back-check activation

H.7.1 General

The purpose of this test is to determine the minimum hydrostatic flow rate needed to activate (close) the reverse-flow or back-check system for flow-activated designs.

H.7.2 Test procedure

a) Conduct a flow test, in the direction opposite to normal flow through the flow-control device;

b) This test may be conducted on an assembled flow-control device or on a disassembled flow-control device with the necessary components for the reverse-flow or back-check assembly;

Page 28: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

c) Record the minimum flow rate and differential pressure necessary to close the back-check valve (to achieve pressure build up);

- for V0, maintain this close pressure for a minimum of 10 minutes and repeat test from a) to c) two times.

H.7.3 Acceptance criteria

H.7.3.1 V3, V2, and V1 acceptance criteria

For acceptance of the minimum liquid flow rate and differential-pressure activation test, each test result shall meet the test requirements specified in the supplier/manufacturer’s written test procedures that ensure the back-check operates correctly.

H.7.3.2 V0 acceptance criteria

In addition to meeting the H.7.3.1 criteria, the back-check valve shall close at a differential pressure less than 1.7 bar (25 psi).

H.8 Pressure differential test for normally closed back-check activation

H.8.1 General

The purpose of this test is to determine the minimum differential pressure needed to activate (open) the normally closed back-check valves. This test may be conducted on an assembled flow-control device or on a flow-control device with the necessary components for the back-check sub-assembly.

H.8.2 Test procedure

a) This test is conducted in the direction of normal flow through the FCD;

b) Apply differential hydraulic pressure in the direction of normal flow through the FCD;

c) Record the minimum differential pressure that is necessary to open the back-check valve:

- For V0, after pressure build up, bleed off the pressure above the FCD to see if the pressure below the FCD is maintained and repeat test from a) to c) two times.

H.8.3 Acceptance criteria

For acceptance of the test of spring-loaded back-check FCDs, the pressure differential to open the back-check valve shall be within the supplier/manufacturer's specified tolerances.

H.9 Full scale gas flow test

H.9.1 General

The purpose of this test is to determine the ability of the back-check valve to function properly after being subjected to a gas flow and 100 open-close cycles.

H.9.2 Test Procedure

a) Prepare the gas flow test facility according to procedures. Remove all water from the gas flow test loop. Position the device in the test cell fixture and perform a gas leakage test in the laboratory to verify that outer packings are activated. Perform gas leakage test according to documented procedures from the supplier/manufacturer;

Page 29: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

b) The device shall be installed horizontally in the test loop such that flow is initiated through the back-check valve in the direction that allows free flow. Adjust operating parameters such as temperature and pressure;

c) The test shall be conducted by initiating flow of natural dry gas and adjusting control valves or the pump such that a steady and continuous flow rate of approximately 5000 SCMD (176.5 MSCFD) achieved;

d) Increase the gas flow rate in steps of approximately 5000 SCMD (176.5 MSCFD) to maximum gas flow rate (at least 100,000 SCMD). At each step flow with stable gas rate for 5 minutes. Log flow rate and differential pressure across the device. Observe for abnormal behavior and noise. Bleed off pressure to close the back-check valve with a maximum bleed off rate of 10 bar/min (147 psi/min);

e) Increase the gas flow rate slowly from zero to maximum gas flow rate (at least 100,000 SCMD (3.5 MSCFD)). Flow with stable gas rate for 1 minute. Log flow rate and differential pressure across the device. Observe for abnormal behavior and noise. Bleed off pressure to close the back-check valve with a maximum bleed off rate of 10 bar/min (147 psi/min);

f) Repeat step e) until 100 open-close-open cycles have been repeated;

g) Flow at a steady and continuous flow rate of maximum rated gas flow (at least 100,000 SCMD (3.5 MSCFD)) until the device has seen a minimum of 24 hours of continuous flow;

h) Stop flowing. Remove the test cell fixture and device from the gas flow test loop

H.9.3 Acceptance criteria

For acceptance of the full-scale gas flow test, there shall be no damage to the back-check valve. The dart shall move freely from the open to close position and from the close to open position without human intervention. If any device fails to move as required, the test fails.

Page 30: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

Annex J (normative)

Bellows actuation life cycle testing

J.1 General

This annex provides procedures that shall be followed for lifecycle testing of flow-control device bellows.

J.2 Requirements for design validation

J.2.1 Requirements for design validation, grades V3 and V2

There are no actuation life cycle test requirements for design validation, grades V3 and V2.

J.2.2 Requirements for design validation, grade V1 and V0

J.2.2.1 General

The actuation life cycle test requirements for design validation, grade V1 and V0, shall be as defined in J.2.2.2 to J.2.2.5. For group III pilot FCDs, test only the bellows control subassembly. The following shall be successfully achieved:

a) manufacturer’s defined testing and acceptance criteria;

b) requirements of Clauses J.3 and J.4 for the intended service life.

NOTE This test is applicable only to bellows-operated flow-control devices.

J.2.2.2 Number of test specimens

This test shall be conducted on a minimum of seven flow-control devices of each design family. If one or more devices of the original seven test devices do not meet the requirements of Clause J.4, an additional seven devices shall be selected, and the entire test process shall be performed on the new devices.

J.2.2.3 Test fixture

J.2.2.3.1 Data recording

The test fixture shall allow for data recording of the dome pressure, the operating pressure, the duration of each cycle and the number of cycles to failure. This data shall be recorded directly using an electronic data acquisition system.

J.2.2.3.2 Application of operating pressure

The operating pressure shall be cyclically applied by the use of hydraulic pressure within the range of the minimum operating pressure to the maximum operating pressure. The operating pressure shall be applied both above and below the seat simultaneously.

J.2.2.4 Test procedure

This test shall be conducted in accordance with the procedures defined in Clause J.3.

Page 31: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

J.2.2.5 Performance criteria

Each flow-control device shall be tested until the bellows fails. Failure shall be as defined in Clause J.4.

J.2.2.6 Documentation

The following specific additional documentation is required.

a) The results of the test on all seven flow-control devices shall be reported. The average number of cycles to failure and the standard deviation shall be determined by calculating the average of the seven flow-control devices tested.

b) The minimum number of cycles to failure shall be determined by the flow-control device that failed with the fewest number of cycles. The number of cycles prior to failure for this flow-control device becomes the minimum number of cycles to failure.

c) The maximum number of cycles to failure shall be determined by using the flow-control device that failed with the greatest number of cycles. The number of cycles prior to failure for this flow-control device becomes the maximum number of cycles to failure.

J.3 Procedure for bellows actuation life cycle testing

J.3.1 Upper test pressure

The upper test pressure shall be at least 344.5 kPa (50 psig) greater than the pressure required to achieve maximum stem travel. The load rate shall be determined based on the supplier/manufacturer’s dome charge maximum rating. The flow-control deviceFCD dome set pressure for this test shall be 6895 kPa (1000 psi). If) or the flow-control device is designated as high pressure by the supplier/manufacturer, the flow-control device dome set pressure for this test shall be 50% of theFCD maximum rated dome pressure.charge. J.3.2 Lower test pressure

The lower test pressure is determined by multiplying the closing pressure of the flow-control device being tested by 0.75. This value then becomes the maximum lower pressure that is applied during the life cycle test.

J.4 Test measurements

J.4.1 General

The items in J.4.2 to J.4.5 shall be monitored and recorded in an electronic data acquisition system during the test.

J.4.2 Dome pressure failure criteria

The dome pressure shall be continuously recorded during the test. A change in the upper or lower dome pressure by more than 25 % of the initial values indicates that the bellows of the flow-control device in test has failed and shall be removed from the cycling test.

J.4.3 Cycle duration recording

The duration of each cycle shall be continuously recorded during the test. The duration of each cycle shall be a minimum of 30 seconds and a maximum of 120 seconds.

Commented [WM8]: Design Validation comment 5: No clear dome set pressure was identified making comparison of results between FCD’s not possible. With this change, this version is harmonized with the first edition.

Page 32: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

J.4.4 Operating pressure

During testing the operating pressure cycles between the minimum upper test pressure and the maximum lower test pressure. This operating pressure shall be continuously recorded.

J.4.5 Number of cycles

The number of cycles until failure shall be recorded.

J.4.6 Acceptance Criteria

The minimum number of cycles required to pass the test is 3500-cycles and maximum is to failure. Failure is interpreted to be the point the FCD fails or the test is suspended.

J.5 Presentation of results

J.5.1 Average number of cycles to failure and standard deviation

The results on all seven flow-control devices shall be reported. The average number of cycles to failure and the standard deviation shall be determined by calculating the average of the seven flow-control devices tested.

J.5.2 Minimum number of cycles to failure

The minimum number of cycles to failure shall be determined by the flow-control device that failed with the fewest number of cycles. The number of cycles prior to failure for this flow-control device becomes the minimum number of cycles to failure.

J.5.3 Maximum number of cycles to failure

The maximum number of cycles to failure shall be determined by using the flow-control device that failed with the greatest number of cycles. The number of cycles prior to failure for this flow-control device becomes the maximum number of cycles to failure. If the test is stopped before failure, then the number of cycles at which the test was stopped becomes the failure point for calculation of number of cycles to failure

Page 33: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed
Page 34: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

Annex K (normative)

Erosion testing requirements

K.1 General

K.1.1 Erosion testing

This annex defines the requirements, procedures, and acceptance criteria for erosion testing of flow-control devices. Since erosion testing is a destructive test, it is required only for design validation. Testing shall conform to the requirements of 7.2 and 7.3.

K.1.2 Erosion test scope and method

The liquid flow test is conducted to determine the ability of the reverse-flow check and/or the flow-control device port to function properly after being subjected to a potentially erosive liquid flow. This testing is applicable to products Type I, II, III and IV. This testing requires facilities that can generate and record a liquid flow rate through the reverse-flow check or device port in the direction of normal flow. This testing demonstrates that the device can withstand the erosion forces that can occur during normal unloading or operating conditions.

The erosion testing facility requires a pump that can generate a sustained flow rate of 0.16 m3/min (1 bbl/min) for V3, V2 and V1, however, for V0 a rate of 0.24 m3/min (1.5 bbl/min) is required. Any method of accomplishing this is acceptable. Upstream of the reverse-flow check, a flow rate meter and pressure-measuring device are required. The flow rate meter shall be capable of measuring the flow rate at an accuracy of ± 2 % with continuous readings at intervals not exceeding 10 seconds per reading.

K.2 Requirements for design validation

K.2.1 General

This test is not required if the flow-control device, once opened, is not intended to close and it has no reverse-flow check valve, for example, to dump/kill FCDs.

Testing is performed with fresh water and no temperature constraints.

Testing shall be conducted on one flow-control device. This test does not establish where the device will fail.

K.2.1K.2.2 Requirements for design validation, grade V3

There are no erosion test requirements for design validation, grade V3.

K.2.2K.2.3 Requirements for design validation, grades V2 and V1

K.2.2.1 General

This test is not required if the flow-control device, once opened, is not intended to close and it has no reverse-flow check valve, for example, to dump/kill FCDs.

The design validation requirements for grades V2 and V1 follow.

Testing is performed in an open system with fresh water and no temperature constraints.

Commented [WM9]: Design Validation comment 6: Suggested editorial format changes submitted by Ian Schuur. Accepted into revision.

Commented [WM10]: Design Validation comment 7: Removed open system to allow a single erosion test for both the back-check and port.

Commented [WM11]: Editorial

Commented [WM12]: Design Validation comment 8: Removed open system to allow a single erosion test for both the back-check and port.

Page 35: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

K.2.2.2 Number of test specimens

Testing shall be conducted on one flow-control device. This test does not establish where the device will fail. It demonstrates that the device can withstand the erosion forces that can occur during normal unloading conditions.

K.2.2.3K.2.3.1 Test procedure

Conduct testing as specified in Clauses K.3 and/or K.4, as applicable.

K.2.2.4K.2.3.2 Acceptance criteria

Both before and after conducting the erosion test, the back-check shall have successfully completed the liquid backflow integrity test (H.5.2) and depending on the type of back-check either the minimum liquid rate for hydraulically activated back-check activation (H.7) or the minimum liquid activation test for pressure differential test for normally closed back-check activation (H.8).

Acceptance criteria is defined within the test procedure.

K.2.2.5K.2.3.3 Documentation

Report the results of the testing.

K.2.3K.2.4 Requirements for design validation, grade V0

Erosion back-check system testing requirements for design validation grade V0 are integrated within the back-check system validation process (Clause H.2.5) and defined in Clause K.3. Port erosion testing requirements are defined in Clause K.3.clause K.4.

General

Erosion back-check system testing requirements for design validation grade V0 are integrated within the back-check system validation process (Clause H.2.5) and defined in Clause K.3. Port erosion testing requirements are defined in clause K.4.

These tests are not required if the flow-control device, once opened, is not intended to close and it has no reverse-flow check valve, for example, to dump/kill FCDs.

Testing is performed with fresh water and no temperature constraints.

Number of test specimens

Testing shall be conducted on one flow-control device. This test does not establish where the device will fail.

K.2.4.1 Test procedure

Erosion test procedure for the back-check system design validation grade V0 are integrated within clause H.2.5. Port erosion test requirements are defined in Clause K.3. The port erosion test shall be conducted as defined in clause K.4.

K.2.4.2 Acceptance criteria

Acceptance criteria for the back-check erosion test are defined in clause K.3.2.2. Acceptance criteria for port erosion test are defined in clause K.4

Commented [WM13]: Editorial

Commented [WM14]: Design Validation comment 9: Moved to test procedures.

Commented [WM15]: Design Validation comment 10: Clearly define the V0 backchecks requirements.

Page 36: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

K.3 Reverse-flow check erosion test

K.3.1 General

The reverse-flow check erosion test is conducted to determine the ability of the reverse flow check to function properly after being subjected to an erosive liquid flow.

a) The reverse flow check shall be installed in the test fixture such that flow is initiated through the reverse-flow check in the direction that allows free flow.

b) The erosion test shall be conducted by initiating a flow of fresh water and adjusting the control valves or the pump such that a steady and continuous flow rate of the following rates:

1) For V2 and V1: 0.16 m3/min (1 bbl/min) is achieved and maintained for V2 and V1

2) For V0: 0.23 m3/min (1.5 bbl/min) is achieved and maintained for V0

c) This flow rate shall be maintained to pass through the reverse-flow check a total of at least the following:

1) For V2 and V1: 63.6 m3 (400 bbls) of liquid for V2 and V1

2) For V0: 95.4 m3 (600 bbls) of liquid For V0

K.3.2 Erosion testing acceptance criteria

K.3.2.1 V2 and V1 acceptance criteria

Items a) and b) below shall be successfully completed both prior to and after the erosion test. The erosion testing acceptance criteria for design validation grade V2 and V1 shall be as follows:

a) All liquid backflow integrity tests (H.5.2) shall satisfy the acceptance criteria as detailed in H.5.3;

b) All back-checks shall satisfy the acceptance criteria for either:

1) The minimum liquid rate for hydraulically activated back-checks (H.7) or;

2) The minimum liquid activation test for normally closed back-check activation (H.8).

c) After erosion flow, maintain the differential pressure required to activate the reverse-flow check and record the pressure loss after a 10 min time span. If the reverse-flow check is unable to maintain at least 90 % of the differential pressure required to activate it after the 10 min time span, the reverse-flow check fails the erosion test.

d) After the erosion test, the reverse-flow check shall be tested again to determine the ability to impede flow from the reverse direction. This is accomplished by performing the activation test in accordance with Clause H.7 or H.8 as appropriate.

e)c) There shall be no damage to the back-check valve. The and the dart should move freely from open to close position and from close to open position without human intervention. If any device fails to move as required, the test fails.

K.3.2.2 V0 acceptance criteria

The erosion testing acceptance criteria for design validation grade V0 shall be as follows:

a) The back-check erosion testing acceptance criteria as defined in H.2.5 shall be satisfied.

Commented [WM16]: Editorial

Commented [WM17]: Design Validation comment 11: Design Validation Review: Add clarity and correct mistake in erosion acceptance criteria from earlier version for V2 and V1 requirements.

Page 37: Flow-control Devices for Side-pocket Mandrelsballots.api.org/ecs/sc19/ballots/docs/19G2_e2-20190924.pdf · 9/24/2019  · In this procedure, only steps d) through j) shall be followed

This document is not an API Standard; it is under consideration within an API technical committee but has not received all approvals required to become an API Standard. It shall not be reproduced or circulated or quoted, in whole or in part, outside of API committee activities except with the approval of the Chairman of the committee having jurisdiction and staff of the API Standards Dept. Copyright API. All rights reserved.

a)b) There shall be no damage to the backcheck valve. The and the dart should move freely from open to close position and from close to open position without human intervention. If any device fails to move as required, the test fails.

K.4 Port erosion test

K.4.1 General

The port erosion test is conducted to determine the ability of the flow-control device port/stem seat interface to function properly after being subjected to an erosive liquid flow. This test shall be conducted on one or more of the flow-control devices that passed the flow-control device port leak test following the steps a) through e).

a) Prior to erosion testing, the flow-control device port shall be leak-tested in accordance with Clause M.4.

b) The flow-control device shall be installed in the test fixture such that flow is initiated through the port in the direction that allows free flow.

c) The erosion test shall be conducted by initiating a flow of fresh water at pressure adequate to maintain the FCDs group I, II, and III, fully open. The erosion test shall be conducted at a steady and continuous flow rate of not less than 0.16 m3/min (1 bbl/min) and maintained for a total of at least 63.6 m3 (400 bbls) of liquid.

d) The flow-control device port shall be leak-tested again in accordance with Clause M.4.

K.4.2 Erosion testing acceptance criteria

The flow-control device shall meet the acceptance criteria defined in M.4.5.

Commented [WM18]: Design Validation comment 12: Add clarity to the V0 acceptance criteria.

Commented [WM19]: Design Validation comment 13: This change allows for a single test to be conducted for V0 by setting minimum flow rate and total liguid quantities so the V0 check test can be simultaniouslly tested rather than forcing a second test just for port errosion.