14
Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Embed Size (px)

DESCRIPTION

Florida Operations Level Hazardous Materials Training Program Hazard Based Response The process of developing personal protective measures designed to specifically address the hazards that are present at the scene in order to achieve an acceptable level of risk Unit 3.3  3

Citation preview

Page 1: Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations Level Hazardous Materials Training

Unit 3.3Personal Protective Equipment (Core)

Page 2: Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations LevelHazardous Materials Training Program

Objectives Describe the principles of hazards based

response Identify protective measure considerations

for life saving rescues Determine appropriate PPE Identify basic capabilities and limitations of

various types of PPE

Unit 3.3 2

Page 3: Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations LevelHazardous Materials Training Program

Hazard Based Response

The process of developing personal protective measures designed to

specifically address the hazards that are present at the scene in order to achieve

an acceptable level of risk

Unit 3.3 3

Page 4: Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations LevelHazardous Materials Training Program

Hazard Based Response

Acceptable risk Step 1: Identify

hazards Step 2: Develop

measures to reduce each hazard

Unit 3.3 4

Page 5: Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations LevelHazardous Materials Training Program

Identify and Reduce HazardsThermalEtiologicalAsphyxiationMechanical/ElectricalChemicalPsychologicalRadiological

Unit 3.3 5

Page 6: Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations LevelHazardous Materials Training Program

Personal Protection

Minimum level of protection for operations level responders

Unit 3.3 6

Page 7: Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations LevelHazardous Materials Training Program

Respiratory Protection

Air Purifying Respirators (APRs) Limitations and use criteria 100:1 PF for full face

Supplied Air Breathing Apparatus (SABA) Tethered air lines with escape capability 10,000:1 PF for positive pressure

Positive Pressure SCBA Highest level of protection, 10,000:1 PF

Unit 3.3 7

Page 8: Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations LevelHazardous Materials Training Program

Dermal Protection

Support garments (NFPA 1993)

Specialized thermal Splash protective Vapor protective

Unit 3.3 8

Page 9: Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations LevelHazardous Materials Training Program

Level “C” Protective Clothing Respiratory: APR Dermal: Splash Limitations:

Must know contaminant Must measure Must have 19.5% O2

Must have proper filter

Unit 3.3 9

Page 10: Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations LevelHazardous Materials Training Program

Level “B” Protective Clothing

Respiratory: PP/SCBA or SABA Dermal: Splash Minimum for unknown Limitations:

Not for IDLH skin Excellent respiratory Used for incidental splash only

Unit 3.3 10

Page 11: Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations LevelHazardous Materials Training Program

Level “A” Protective Clothing

Respiratory: PP/SCBA Dermal: Vapor protective Limitations:

No thermal protection High heat stress hazard Good for repeated contact or

high vapor concentrations

Unit 3.3 11

Page 12: Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations LevelHazardous Materials Training Program

Summary Table of Levels

BASIC LEVELS OF PROTECTIONEquipment/Level Level D Level C Level B Level AGarment type

None XBunker gear X

Chemical Splash X XVapor Protective X

Respiratory ProtectionNone X

Air Purifying XPositive Pressure

supply air or SCBAX X X

Note: Full firefighter protective clothing provides a high level of respiratoryprotection but a low level of skin protection, therefore it is classified as level "D"but has limited applications in the hazard area.

Unit 3.3 12

Page 13: Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations LevelHazardous Materials Training Program

Summary

Hazards based response Personal protective equipment

Unit 3.3 13

Page 14: Florida Operations Level Hazardous Materials Training Unit 3.3 Personal Protective Equipment (Core)

Florida Operations Level Hazardous Materials Training

Module Activity 3.3“Hazard Based Response”