13
Floor Warming

Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor

Embed Size (px)

Citation preview

Page 1: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor

Floor Warming

Page 2: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor

2

RaySol System

Page 3: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor

3

RaySol Applications

•Freezer Frost Heave Prevention

•Concrete Floor Warming

•Heat Loss Replacement

•Tile and Marble Floor Warming

Page 4: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor

4

Tile and Marble Floor Warming

•Application Overview

– Not primary heat source - comfort heat

– Residential bathrooms

– Embedded in mortar under tile

– Low density concrete

(Gypcrete) often used

Page 5: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor

5

Heat Loss Replacement

•Application Overview

– Used in areas over unheated space such as parking garage

– Objective is to have net zero heat flux

– Run in conduit or attached to bottom of floor

Page 6: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor

6

Concrete Floor Warming

•Application overview

– Not primary heat source - comfort heat

– Schools, gymnasiums, bathrooms

– Run in conduit

Page 7: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor

7

Frost Heave Prevention

•Application Overview

– Moisture in ground under cold storage areas (<32 degrees) freezes forcing up floors

– Insulation slows, but does

not prevent, freezing

Page 8: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor

8

RaySol Installation Methods

• Embedded in mortar

• In conduit embedded in concrete

• In conduit embedded in subsoil

• Attached to the bottom of concrete floor

Page 9: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor

9

Tyco Thermal Controls Solution

• Self-regulating heating cable– RaySol 1 and RaySol 2

• Components– FTC-XC, FTC-P -- Power connections

– RayClic-E -- End Seal

• Design Software– Automated design guide (RS-ADG)

• Literature

– Design guide

– Installation and operation manual

– Installation instructions

Page 10: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor

10

Define the Application

•Each section of the design Guide is a Unit

Page 11: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor

11

Select the Heating Cable Spacing

•Use the proper table to select spacing and determine amount of heating cable required.

Page 12: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor

12

Heating Cable Layout

•Determine the heating cable and component layout for your application.

Page 13: Floor Warming. 2 RaySol System 3 RaySol Applications Freezer Frost Heave Prevention Concrete Floor Warming Heat Loss Replacement Tile and Marble Floor

13

Design the Electrical System

•Use the maximum circuit length to determine the number of circuits required.